Documente Academic
Documente Profesional
Documente Cultură
V100R005C00SPC321
Performance Counter List
Issue 01
Date 2012/07/09
Notice
The purchased products, services and features are stipulated by the commercial contract made between Huawei and the c
partial products, services and features described in this document may not be within the purchased scope or the usage sc
otherwise agreed by the contract, all statements, information, and recommendations in this document are provided "AS IS
warranties, guarantees or representations of any kind, either express or implied.
The information in this document is subject to change without notice. Every effort has been made in the preparation of this
ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute
any kind, express or implied.
Version
The corresponding product versions of this document are as follows:
•NE Type: eNodeB
•Match Version: iManagerM2000_DBS3900LTE_MATCH_ENG_V200R012C00SPC009
•NE Version: DBS3900 LTE V100R005C00SPC321
•IDBegin-IDEnd: 1526726656-1543503871
Measured Feature
•Measurement Modes: By all counters (NEs report the measurement results of all counters in a default meas
•Default Measurement period: 60min
Intended Audience
This document is intended for:
• Network planners
• Field engineers
• System engineers
• Network operators
Organization
The following describes the attributes of counters and performance objects:
Tab Page Attribute
FunctionSet ID
FunctionSet Name
FunctionSubSet ID
FunctionSubSet Name
Supported Period(minutes)
ObjectType ID
Object Name
Counter ID
Counter Name
Counter Unit
Counter Type
Counter Precision
Counters
Time Statistical Method
Counters
Formula
Visible
Default Measured(Yes/No)
FunctionSubSet ID
M2000 Performance Object Name
EnumID
ElementValue
ENUM Objects
ElementName
ElementDescription
unters and performance objects.
e as follows:
3900LTE_MATCH_ENG_V200R012C00SPC009
05C00SPC321
ance objects:
Description
ID of the function set (also called measurement set)
Name of the function set (also called measurement set)
ID of the function subset (also called measurement unit)
Name of the function subset (also called measurement unit)
Measurement periods supported by a Network Element (NE)
ID of the performance object type corresponding to a function subset
Name of the performance object type corresponding to the function subset
ID of the counter
Name of the counter
Unit of the counter
Value type of the measurement result. For example, UINT,4 indicates that the
value is of the unsigned int type and has four bytes, and Float,8 indicates
that the value is of the float type and has eight bytes.
Precision of the measurement result.
This attribute is valid for measurement results of the string type and indicates
the maximum number of characters that can be contained in a measurement
result.
This attribute is also valid for measurement results of the floating-point type if
measurement results are exported on the basis of measurement units and
indicates the number of decimal places. For example, the precision of 123.239
is 3.
The way to aggregate the counter results from a short period to a long period
SUM: sum
AVG: average value
MAX: maximum value
MIN: minimum value
NULL: not support the aggregation of the counter results from a short period
to a long period
The way to aggregate the counter results from multiple performance objects
SUM: sum
AVG: average value
MAX: maximum value
MIN: minimum value
NULL: not support the aggregation of the counter results from multiple
performance objects
If a formula is provided, the counter is calculated by other counters through
the formula.
Whether the counter is visible on the M2000 Graphic User Interface (GUI).
The value of 1 indicates that the counter is visible on the M2000 GUI. Visible
counters are meaningful for customer applications such as network
optimization and troubleshooting. Visible counters are described in the
Performance Counter Reference and their change information is provided in
the Release Notes.
The value of 0 indicates that the counter is invisible on the M2000 GUI.
Invisible counters are internal sampling points used for calculating the visible
counters inside the M2000. The calculation relationship is shown in the column
of Formula.
Both visible counters and invisible counters are visible on the Northbound
Interface.
YES indicates that this counter is measured by default.
NO indicates that certain settings on the M2000 are needed before this
counter is measured.
FDN IP eNodeBMPT.name
FDN IPPATH eNodeBIPPATH.name
FDN RSCGRP eNodeBRSCGRP.name
FDN IPPMSESSIONeNodeBIPPMSESSION.name
FDN SCTP eNodeBNE.name
FDN IPv6 eNodeBIPv6.name
FDN IPv6Path eNodeBIPPath6.name
FDN OMCH eNodeBOMCh.name
FDN TUNNEL TUNNEL.name
M2000 Performance Object Name[level 4] M2000 Performance Object Name[level 5] M2000 Performance Object Name[level 6]
Tag Value Type Tag Value Type Tag
mance Object Name[level 6]
Value
ElementDescriptio
EnumID ElementValue ElementName
n
None None None None
The description of M2000 Performance Object Name tab page is:
M2000 Performance ObjectName[level n]
Type Tag Value
STRING,LEN=[1,13],VA
LIDCHAR=[10,1234567
890],
SELECTABLESTRINGS
INPUT Called Number =[1,ALL]
STRING,LEN=[9,17],VA
LIDCHAR=[12,1234567
890@.],
SELECTABLESTRINGS
INPUT Local IP =[1,<NULL>]
83886586.ElementNam
ENUM Connection Type e
LEN=[1,16],VALIDCHA
INTERNAL DEST Cell ID R=[10,0123456789]
t Name tab page is:
Description