Sunteți pe pagina 1din 227

MODEC OFFSHORE PRODUCTION SYSTEMS (SINGAPORE) PTE LTD

MODEC OFFSHORE PRODUCTION SYSTEMS (SINGAPORE) PTE LTD
FPSO SONG DOC PRIDE MV 19
FPSO SONG DOC PRIDE MV 19
GENERATOR TURBINE
MASTER COPY

40VD‐0004
GENERATOR TURBINE
(SHINKO IND. LTD)

BOOK 1 OF 4

40VD‐0004
BOOK 1 OF 4
2008
SHINKO MASTER COPY
CONTENTS
PAGE NO.

COUPLING (HIGH SPEED SIDE) 1

COUPLING (LOW SPEED SIDE) 2

SEALING STEAM CONTROLLER & VALVES 3

SOLENOID VALVE 4

PRESSURE SWITCH 5

LIMIT SWITCH 6

TURBINE ROTOR VIBRATION MONITOR 7

TURBINE ROTOR AXIAL MOVEMENT MONITOR 8

LO COOLER 9

250A DRAIN SEPARATOR 10

DRAIN TRAP FOR DRAIN SEPARATOR 11

PRIMING OIL PUMP MOTOR 12

PRIMING OIL PUMP 13

DUPLEX OIL STRAINER (CONT. OIL & LUBE OIL) 14

L.O. TEMPERATURE CONTROL VALVE 15

SHORT PIPING FOR EXHAUST OF STEAM TURBINE 16


Configuration/Settings tables
FOR PRIMING OIL PUMP MOTOR

ATS 48 starter …………………………………………………………………………………………………


Customer identification no. (if applicable) …………………………………………………………………
Access code (if applicable) ……………………………………………………………………………………

Settings menu

Code Factory setting Customer setting Code Factory setting Customer setting
(1) 18.8 15s
400% 700% 20%
15s 10s 50%
20% 10% 20%
-F- -F-

The parameters in shaded boxes appear if the corresponding functions have been configured.

Protection menu

Code Factory setting Customer setting Code Factory setting Customer setting
10 10 100
OFF OFF no no
60% 2s 2s
60% 10% 10%
OFF OFF OFF OFF
OFF OFF OFF OFF
80% no no

The parameters in shaded boxes appear if the corresponding functions have been configured.

(1) Depends on the starter rating.

MESSRS. : MODEC, INC.


PROJECT : WT214 FPSO
Configuration/Settings tables

Advanced settings menu

Code Factory setting Customer setting Code Factory setting Customer setting
OFF OFF 50% 50%
OFF OFF 40% 40%
OFF OFF OFF OFF
OFF OFF (1) 440
On On AUt AUt

The parameters in shaded boxes appear if the corresponding functions have been configured.

I/O menu

Code Factory setting Customer setting Code Factory setting Customer setting
LIA LIA r1l r1l
LIL LIL rn1 A1l
0% OCr OCr
5mn 020 020
tA1 tA1 200 200
rn1 rn1

The parameters in shaded boxes appear if the corresponding functions have been configured.

(1) -ATS 48 … Q:400V


-ATS 48 … Y:460V