A I. GENERAL NOTES
PROVIDE TWO SETS OF
1. CONSTRUCTION NOTES AND TYPICAL DETAIL APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED. STIRRUPS @ SPLICE

FTB FTB FTB MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAM OF ALL STRUCTURAL STEEL, MISCELLANEOUS IRON, EXTRA TOP BARS
@ END SUPPORT
EXTRA BOTT. BARS
@ MID SPAN 2-12D
2-16D
PRETRESS, PRECAST WORKS, ETC. SHALL BE SUBMITTED FOR STRUCTURAL ENGINEERS APPROVAL.

350
C1F1 C1F1 C1F1 C1F1

300
3. CONSTRUCTOR SHALL VERIFY ALL DIMENSION BEFORE ANY WORK BEGUN, CHECK MECHANICAL & ELECTRICAL L/4 BREATH

200

150
WF
CONTRACTORS FOR CONDUITS, PIPE SLEEVES ETC. TO BE EMBEDDED IN CONCRETE. 1-12D 2-12D 2-16D 2-16D

H/4
FTB
4. IT SHALL BE THE CONSTRUCTOR RESPONSIBILITY TO PROVIDE ADEQUATE BRACING OF THE STRUCTURES FOR MAIN VERTICAL 150
150 150

DEPTH
ALL LOADS THAT MAY BE IMPOSED DURING CONSTRUCTION. 150
COLUMN REINF.
5. IN THE INTERPRETATION OF THIS DRAWINGS, INDICATED DIMENSION SHALL GOVERN AND DISTANCES OR SIZES 10D STIRRUPS 1@150, 10D STIRRUPS 1@150, 10D STIRRUPS 1@150, 10D STIRRUPS 1@150,
SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. REST @ 300 3@200, REST @ 300 3@100, REST @ 300 3@100, REST @ 300
6. ALL CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE LATEST ACI SPECIFICATIONS, IN SO FAR MAX. SPAN
MAX. SPAN MAX. SPAN MAX. SPAN
3.50

L/5 30Db 1.20M


FTB

AS THEY DO NOT CONFLICT WITH LOCAL BUILDING CODE AND THIS NOTES. 2.50M 3.50M 4.0M
30Db>16D & larger bars

WF 7. USE STRUCTURAL EPOXY FOR ALL CONSTRUCTION JOINTS AT WATER TANK, TOILET SLABS AND ROOF DECK
SLAB
40Db>12D & smaller bars

COLUMN REINF. BARS SHALL ABOVE DOOR / WINDOW OPENINGS ON CHB WALL
BE SPLICE AT TWO LEVELS (EXTEND 300MM FROM EDGES OF MASONRY OPENINGS)

H/2
WITH NUMBER OF BARS PER TYPICAL DETAIL OF COLUMN

LAP SPLICE
II. DESIGN CRITERIA LEVEL @ LEAST 50% OF NO.
LAP SPLICE & EXT. BEAM TO
E. DESIGN STRESSES OF MAIN VERT.BARS
A. LIVE LOADS
A.1 ROOF LIVE LOADS E.1 REINFORCED CONCRETE, fc' =
RECOMMENDED HOOPS
COLUMN CONNECTION 4-12D, 2.0M LONG
12D, 1.0 METER LONG @
E.1.1 BEAMS, COLUMNS, SUSPENDED SLABS MID-DEPTH OF SLAB @
ROOF = 1.00 KPa TOP BAR BEND DOWN
DUE TO PONDING
A.2 FLOOR LIVE LOADS
= 0.75 KPa fc' = 21 MPa
E.1.2 SLAB ON FILL
S=0.25d <100MM
0
INTO EDGE BEAM
EACH OPENING CORNER
OMIT BARS WHERE OPENING
IS FRAMED BY BEAM
BUILDING OFFICIAL DATE
COLUMN MAIN REINF. 55
OFFICE = 2.40 kPa fc' = 17.5 MPa
LOBBY = 4.80 kPa E.1.3 FOOTINGS BAR SPLICE SHALL BE

H/4
LIMITED @ MIDHEIGHT, 0
B. DEAD LOADS fc' = 21 MPa 55
= 0.24 kPa H/2 MIN.=30 Db MIN.=30 Db

55
GB GB B.1 FLOOR MORTAR FINISH E.2 REINFORCING STEEL

0
B.2 PARTITION = 0.75 kPa OPEN
E.2.1 INTERMEDIATE BARS (deformed)
B.3 CEILING AND UTILITIES = 0.40 kPa

B C. WIND LOADS
fy = 276 MPa (10MM, 12MM, 16MM, 20MM)
E.2.2 HARD GRADE BARS 4-12D
BOTT.BARS
1-12D TOP &
BOTTOM BARS

DEPTH
2
p = 0.00256V Ch fy = 414 MPa (25MM)

125mm THK.

DEPRESSION
V = WIND VELOCITY

(VERIFY)
Ch = HEIGHT CORRECTION FACTOR E.2.3 STRUCTURAL STEEL, USE ASTM A36
FOR SEISMIC REQM'T
E.3 FOUNDATION PROVIDE TIES AT LEAST

C1F1 concret slab ON C1F1


D. SEISMIC LOAD
V = ZIC W/Rw E.3.1 SOIL BEARING CAPACITY = 133 KPa THREE (3) TIES @ COLUMN

C1F1 where: E.3.2 IN CASE THE ACTUAL SOIL BEARING


BEAM CONFINEMENT
MIN.=30 Db DEPTH

Fill @ 600mm V= BASE SHEAR CAPACITY IS LESS THAN THE ASSUMED TYPICAL SLAB

FTB
Z= 0.40 VALUE THE ENGINEER IN CHARGE OF TYPICAL SLAB
FTB

OPENING DETAIL
10.00

C = 1.25S/(T^(2/3))<2.75 THE CONSTRUCTION SHALL NOTIFY THE CORNER DETAIL


3.00

I = 1.0
TYPICAL COLUMN ELEVATION TYPICAL DETAIL FOR BEAM
STRUCTURAL ENGINEER FOR SOME
W= DEAD LOAD RECOMMENDATION. OR SLAB CHANGE SOFFIT
150MM THICK 150MM THICK
III. CONSTRUCTION NOTES CHB WALL W/ CHB WALL W/ MAIN REINF BARS
10D @ 600 E.W. 10D @ 600 E.W.
A. REINFORCED CONCRETE

T
SLAB ON GRADE SLAB ON GRADE
A.1. THE QUALITY AND DESIGN OF ALL REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM WITH

Y<250
THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI - 318.95) AND MANUAL OF PROVIDE 3 ADDT'L

C1F1 C1F1 STIRRUPS EACH SIDE

DEPTH
STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI - 315).
OF THE SLEEVES
A.2. ALL CONCRETE SHALL BE MACHINE MIXED AND MECHANICAL VIBRATOR SHALL BE USED FOR
COMPACTING CONCRETE.

WF A.3. MINIMUM CONCRETE COVERING FOR REINFORCING STEEL SHALL BE: 38MM - BEAMS AND
COLUMNS, 38MM - FORMED SURFACE BELOW GRADE. FOR 16MM DIA. BARS AND SMALLER = 50MM.
NGL EARTH FILL
SLEEVES FOR UTILITY
(PIPE MIN DIAM.=50MM)

C FOR BARS LARGER THAN 16MM DIAMETER CONCRETE POURED AGAINST EARTH = 75MM.

A.4. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND OTHER INSERTS SHALL BE WELL SECURED
BREATH CONTINOUS MAIN
REINFORCEMENTS

200
200
IN POSITION BEFORE PLACING THE CONCRETE.
TYPICAL SLEEVES DETAIL Db x1000
A.5. NO CONCRETING SHALL BE ALLOWED UNLESS ALL BAR PLACEMENTS HAVE BEEN INSPECTED BY THE
STRUCTURAL ENGINEER.
THRU CONCRETE BEAM @300 O.C.

19
400 400

C1F1 B. CONCRETE MASONRY UNITS WF-1 WF-4 VERTICAL REINF.

t
150MM THICK 150MM THICK
COLUMN TIES

t-38
B.1. CELLS CONTAINING REINFORCEMENTS SHALL BE SOLIDLY FILLED WITH GROUTS NOT TO EXCEED CHB WALL W/ CHB WALL W/

19
1.2 METERS AND POURING SHALL BE STOPPED 38MM BELOW AT TOP OF A COURSE TO FORM A 10D @ 600 E.W. 10D @ 600 E.W. REINF. BARS
KEY AT POURED JOINTS. NGL ALONG X SLAB
125mm THK. 125mm THK. REINF. BARS
FTB

MIN. D=1.2M
B.2. VERTICAL CELLS TO BE FILLED SHALL HAVE A VERTICAL ALIGNMENT TO MAINTAIN A CONTINUOUS
ALONG Y MIN.=30Db D MIN.=30Db
UNOBSTRUCTED CELL AREA NOT LESS THAN 50MM X 75MM.
3.50

50 MM LEAN

FTB
concret slab ON
WF

concret slab ON B.3. VERTICAL BARS SHALL BE HELD IN POSITION AT TOP AND BOTTOM OF THE REINFORCEMENTS AND CONCRETE

T
AT INTERVALS NOT EXCEEDING 192 BAR DIAMETER. 3-10D
3-10D 10D

50
10D

Fill @ 400mm Fill @ 400mm B.4. PROVIDE 10 DIAM. DOWELS X 900MM LONG @ 600MM ON CENTERS. DEPRESSED

50
SLAB X DIRECTION
WF

100

D
150
C. REINFORCING STEEL
C.1. REINFORCEMENTS SHALL BE DEFORMED BRAS CONFORMING TO ASTM A-615 (DEFORMATION).

100

100
100
C.2. MINIMUM LAP SPLICES UNLESS OTHERWISE INDICATED SHALL:
PROVIDE SHEAR RODS

Y DIRECTION
C.2.1 FOR CONCRETE = 30 BAR DIAMETER BUT NOT LESS THAN 300 MM. WHERE JOINT IS @
100 400 100 100 400 100
C.2.2 FOR UNIT MASONRY = 40 BAR DIAMETER. MAIN REINFORCEMENTS POINT OF STRESS

C 1F 1 C1F1 C1F1 SF C1F1 D. FOUNDATION WF-3 WF-2


TO & BOTTOM CONT.BARS

ALL FOOTINGS SHALL REST ON NATURAL GROUND. BEAM

FTB FTB FTB E. DISCREPANCY


ALL DISCREPANCY BETWEEN THE DESIGNERURAL AND STRUCTURAL PLANS SHALL BE REPORTED TO
TYPICAL CONCRETE HOLLOW BLOCK
WALL FOOTING (WHERE APPLICABLE)
TYPICAL FOOTING DETAIL TYPICAL SLAB AND BEAMS
CONSTRUCTION JOINT DETAIL
D THE DESIGNER BEFORE PROCEEDING WITH THE PORTION OF THE WORK INVOLVED.

ELEV.
FOUNDATION PLAN +00
SCALE 1 : 100 M

100mm THK
CHB WALL

VERT. BARS
HOR. BARS
@ EVERY 3RD
LAYER. L1/4+12D L1/4+12D L2/4+12D BREATH
L2/4+12D

TOP BARS

STIRRUPS

DEPTH
(TYPICAL)
400

WEB BARS
D24

FIN. FLR. LINE


L/7 STIRRUPS L/5 L/5
10mm BOTTOM BARS
200

EXTCOL L/5 INTCOL INTCOL L3 (CANTILEVER SPAN)


L1(END SPAN) L2 (INTERIOR SPAN)

ZOC. BARS
TIES @ 300
ON CENTER 400
SCHEDULE OF BEAMS

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


C:\Users\user\Documents\calimbas plan\logo copy.bmp
COPIED EITHER MANUALY OR ELECTRONICALLY SLSU ALUMNI
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. LUMEN ANGELO M. EWAY
CIVIL ENGINEER OWNER
PRC No.: 0141441 Date Reg. T I N No. LOCATION: BRGY. SAN ROQUE,SOGOD, SOUTHERN LEYTE LOCATION: BRGY. SAN ROQUE,SOGOD, SOUTHERN LEYTE
PTR No.5117019 Date: 06-30-2016 Place: MAASIN CITY

S-ar putea să vă placă și