Sunteți pe pagina 1din 36

EURASIAN ECONOMIC COMMISSION COUNCIL DECISION

CU 032/2013

ON TECHNICAL REGULATIONS OF THE CUSTOMS


UNION "ON THE SAFETY OF EXCESS PRESSURE
EQUIPMENT"

Reference number: CU 032/2013


Technormativ IS LLC, translation from Russian, 2014

This document shall be interpreted according to the Russian text. In case of any discrepancy between the Russian text of this document or
any document connected herewith and any translation thereof the Russian text shall prevail.
CU 032/2013

EURASIAN ECONOMIC COMMISSION


COUNCIL
DECISION
02 June 2013 No. 41

ON TECHNICAL REGULATIONS OF THE CUSTOMS UNION


"ON THE SAFETY OF EXCESS PRESSURE EQUIPMENT"

Pursuant to Article 3 of the Treaty on the Eurasian Economic Commission of the18th of November 2011,
the Council of the Eurasian Economic Commission has decided:
1. To adopt the enclosed technical regulations of the Customs union "On the safety of excess pressure
equipment" (CU TR 032/2013).
2. To establish that the technical regulations of the Customs union "On the safety of excess pressure
st
equipment" (CU TR 032/2013) come into force since the 1 of February, 2014
3. This Decision shall come into force after 30 days from its official publication.
The Members of the Council of the Eurasian Economic Commission:
For the Republic of Belarus For the Republic of Kazakhstan For the Russian Federation

S. Rumas K. Kelimbetov I. Shuvalov

2
CU 032/2013

CONTENTS

I. Scope......................................................................................................................................................... 4
II. Basic concepts ......................................................................................................................................... 6
III. Marketing rules ........................................................................................................................................ 8
IV. Provision of safety of the equipment during design (projection), manufacture (fabrication) ................... 8
V. Provision of compliance with safety requirements ................................................................................. 14
VI. Validation (confirmation) of compliance of the equipment .................................................................... 14
VII. Equipment marking by the uniform s
Customs union ............................................................................................................................................ 18
VIII. Disclaimer statement........................................................................................................................... 18
Annex 1 CLASSIFICATION OF THE EQUIPMENT BY HAZARD CATEGORIES ................................... 19
Annex 2 REQUIREMENTS FOR EQUIPMENT SAFETY DURING DESIGN (PROJECTION),
MANUFACTURE (FABRICATION) ............................................................................................................ 23
Annex 3 REQUIREMENTS FOR DISTINCTIVE COLORING AND IDENTIFICATION INFORMATION .. 36

3
CU 032/2013

Adopted by
the decision of the Council of
Eurasian economic commission
from the 2nd of July, 2013 No. 41

TECHNICAL REGULATIONS OF THE CUSTOMS UNION


CU TR 032/2013
ON THE SAFETY OF EXCESS PRESSURE EQUIPMENT
The present technical regulations are developed according to the Agreement on uniform principles and
rules of technical regulation in the Republic of Belarus, Republic of Kazakhstan and the Russian
th
Federation from the 18 of November, 2010.
On the customs territory of the Customs union, present technical regulations establish uniform safety
requirements for excess pressure equipment being newly released and intended for application on the
customs territory of the Customs union (hereafter referred to as "equipment"); these requirements are
obligatory for application and execution and provide free movement of the equipment.
If other technical regulations of the Customs union are adopted for the equipment and establish the
requirements for the equipment, then such equipment shall comply with the requirements of those
technical regulations of the Customs union.
I. Scope
1. The present technical regulations establish safety requirements for the equipment during design
(projection), manufacture (fabrication), and also the requirements for the marking of the equipment for
the purpose of protection of life and health of people, property, and for the purpose of prevention of
consumer-misleading actions.
2. The present technical regulations apply to the following kinds of equipment:
a) the vessels intended for gases, liquefied gases dissolved under pressure, and steams, which are
used for working media of group 1 and have:
maximum possible working pressure from 0,05 MPa, capacity over 0,001 m3 and the product
of the value of maximum possible working pressure by the value of capacity from
0,0025 MPa m3;
maximum admissible working pressure over 20 MPa, capacity over 0,0001 m3 up to 0,001 m3
inclusive.
The categories of the vessels intended for gases and used for working media of group 1 are
given in table 1 of annex N 1 of present technical regulations;
b) the vessels intended for gases, liquefied gases dissolved under pressure, and steams, and used
for working media of groups 2 and having:
maximum admissible working pressure over 0,05 MPa, capacity over 0,001 m3 and the
product of the value of maximum admissible working pressure by the value of capacity over
0,005 MPa m3;
maximum admissible working pressure over 100 MPa, capacity over 0,0001 m3 to 0,001 m3
inclusive.
The categories of the vessels intended for gases and used for working media of group 2 are
given in table 2 of annex N 1 of present technical regulations;
c) the vessels intended for liquids, and used for working media of group 1 and having:
maximum admissible working pressure over 0,05 MPa, capacity over 0,001 m3 and the
product of the value of maximum admissible working pressure by the value of capacity over
3
0,02 MPa m ;
3 3
maximum admissible working pressure over 50 MPa, capacity over 0,0001 m up to 0,001 m
inclusive.
The categories of the vessels intended for liquids and used for working media of group 1 are
given in table 3 of annex N 1 of present technical regulations;

4
CU 032/2013

d) The vessels intended for liquids, groups used for working media 2 and having:
3
maximum admissible working pressure over 1 MPa, capacity over 0,01 m and the product of
3
the value of maximum admissible working pressure by the value of capacity over 1 MPa m ;
maximum admissible working pressure over 100 MPa, capacity over 0,0001 m3 up to 0,01 m3
inclusive.
The categories of the vessels intended for liquids and used for working media of group 2, are
given in table 4 of annex N 1 of the present technical regulations;
e) The boilers of capacity over 0,002 m3 intended for fabrication of hot water of the temperature over
steam of excess pressure over 0,05 MPa, and also the vessels with fire heating of the
3
capacity over 0,002 m .
The categories of steam, water-heating boilers and vessels with fire heating are given in table 5
of annex N 1 of the present technical regulations;
f) the pipelines of maximum admissible working pressure over 0,05 MPa, nominal diameter over
25 mm intended for gases and steams and used for working media of group 1.
The categories of pipelines intended for gases and steams and used for working media of group
1 are given in table 6 of annex N 1 of the present technical regulations;
g) the pipelines having maximum admissible working pressure over 0,05 MPa, nominal diameter
over 32 mm and the product of the value of maximum admissible working pressure by the value
of nominal diameter over 100 MPa
media of group 2.
The categories of pipelines intended for gases and steams and used for working media of group
2 are given in table 7 of annex N 1 of the present technical regulations;
h) the pipelines having maximum admissible working pressure over 0,05 MPa, nominal diameter
over 25 mm and product of value of maximum admissible working pressure upon the value of

media 1.
The categories of the pipelines intended for liquids and used for working media of group 1 are
given in table 8 of annex N 1 of the present technical regulations;
i) the pipelines having maximum admissible working pressure over 1 MPa, nominal diameter over
200 mm and the product of value of maximum admissible working pressure upon value of
nominal diameter over 500 MPa media of
group 2.
The categories of the pipelines intended for liquids and used for working media of group 2 are
given in table 9 of annex N 1 of the present technical regulations;
j) the elements of the equipment (assembly units) and pressure-resistant accessories to the
equipment;
k) the fittings having nominal diameter over 25 mm (for the equipment with working medium of
group 1), the fittings having nominal diameter over 32 mm (for the equipment used for gases with
working medium of group 2), the fittings having nominal diameter over 200 mm (for the pipelines
intended for liquids and used for working media of group 2);
l) indicating and safety devices;
m) pressures chamber (except single-place medical pressure chambers);
n) safety devices and instruments.
3. The present technical regulations do not apply to the following products:
a) main pipelines, the infield and local distributing pipelines intended for transportation of gas, oil
and other products, except for the equipment used at pressure control stations or compressor
stations;
b) gas distribution gas consumption networks;
c) the equipment specially designed for the use in the field of atomic projection, the equipment
operating with the radioactive medium;

5
CU 032/2013

e) the vessels working under pressure created at the explosion inside them according to
technological process or at the burning in the mode of self-distributing high-temperature
synthesis;
d) the equipment specially designed for use on sea and river crafts and other floating crafts and
underwater application objects;
e) brake equipment of the rolling stock of railway transport, motor transport and other transportation
means;
f) the vessels specially designed for use on planes and other flying machines;
g) the equipment of defense purpose;
h) the parts of the machines which are not independent vessels (the cases of pumps or turbines, the
cylinders of steam, hydraulic, internal combustion engines, air machines and compressors);
i) medical single-place pressures chamber;
j) the equipment with aerosol sprays;
k) the covers of the high-voltage electric equipment (switching centers, distributive mechanisms,
transformers and rotating electric machines);
l) the covers and the casings of excess pressure elements of electric energy transfer systems
(cable products, power supplies and communication cables);
m) the equipment which is made (produced) from nonmetallic flexible (elastic) cover;
n) the mufflers of exhaust or gas ingestion noises;
o) the capacities or siphons for aerated drinks.
II. Basic concepts
4. For the purpose of the present technical regulations, applied terms mean the following:
"Cylinder" is a vessel having 1 or 2 mouths for installation of valves, flanges or nozzles intended for
transportation, storage and use of compressed, liquefied gases or the gases dissolved under
pressure;
"Pressure chamber" is a vessel in which lowered and (or) elevated pressure is created; the vessel is
equipped with the devices and the equipment and allows placement of people;
"Burrel" is a vessel of cylindrical or other form which may be rolled from one place on another and put
on end faces without additional support, and which is intended for transportation and storage of liquid
and other substances;
"Commissioning" is documented event registering the readiness of the equipment for application
(use);
"Capacity" is the volume of internal cavity of the equipment which is determined from nominal
dimensions specified by the drawings;
"Group of working media" is the set of working media which are subdivided into:
group 1, which includes working media, consisting of flammable, oxidizing, combustible, explosive,
toxic and highly toxic gases, liquids and steams in single-phase state , and their mixes;
group 2, which includes all other working media which do not refer to group 1;
"Internal pressure ", "External pressure" is excess pressure acting on internal or external surfaces of
equipment walls;
"test pressure " is excess pressure at which the testing of the equipment for durability and tightness is
carried out;
"working pressure" is maximum excess pressure appearing at the normal course of working process;
"allowed pressure " is maximum allowed excess pressure for the equipment (element) established on
the basis of the validation of compliance and (or) control calculation of strength;
"design pressure " is the pressure at which the calculation of strength of the equipment is carried out;

6
CU 032/2013

"schedule pressure" is design pressure at the used at the calculation of strength of


standard vessels (units, parts, fittings);
"nominal diameter", "nominal bore" are numerical designations of the size equal to rounded value of
internal diameter which is indicated for all components of the equipment except for the components
specified by external diameter or by thread size. Nominal diameter and nominal bore are specified in
millimeters without dimension designation;
"equipment identification" is the procedure of reference of the equipment to the scope of the present
technical regulations and establishment of compliance of the equipment with enclosed projection
specifications;
"manufacturer" is legal or physical body registered as individual entrepreneur who, on its own behalf,
executes manufacture or fabrication and realization of the equipment and is responsible for its
compliance with safety requirements of the present technical regulations;
"waste heat boiler" is the device in which combustible gases or other technological streams are used
as the source of heat;
"industrial power boilers" is steam or water-heating boiler (including soda recovery boiler) in fire
chamber of which, processing of technological materials is carried out;
"electrode boiler" is steam or water-heating boiler which uses the heat released at electric current
flow through water;
"electric boiler" steam or water-heating boiler which uses the heat released with by electrical heating
elements;
"water-heating boiler" is the device intended for heating of water being under pressure above
atmospheric and used as the heat-carrier out of this device;
"steam boiler " is the device intended for generation of steam with pressure above atmospheric used
out of this device;
"safety case" is the document containing the analysis of risk, and the data from design, operational
and technological documentation about minimum necessary safety measures; safety case
accompanies the equipment at all the stages of its life cycle and is supplemented with the data of
results of risk estimation at the stage of operation after major repairs;
"limiting condition of the equipment" is the condition of equipment at which its further operation is
inadmissible;
"Intended use" is the use of the equipment according to its purpose and technical characteristics
specified in projection specifications of the manufacturer;
"batch fabrication" is the type of fabrication which is characterized by manufacture of homogeneous
products according to typical design solutions and (or) application of typical technological processes,
related to non-changeable types of the equipment, including that at assemblage operations, for
manufacture (fabrication) of constantly repeating parts of the equipment irrespective of the types of
their further assemblage;
"equipment repair" is the restoration of the elements of vessels which have been damaged, worn out
or got out of order for any reason with bringing them to operable condition;
"specified operating time" is total operating time upon the achievement of which equipment operation
shall be stopped irrespective of its technical condition;
"vessel" is hermetically sealed capacity (permanently installed or portable) intended for executing
chemical, thermal and other technological processes, and also for storage and transportation of
gaseous, liquid and other substances;
"specified life" is calendar duration of equipment operation upon achievement of which the operation
shall be stopped irrespective of its technical condition;
"design life" is service life expressed in calendar years, established during the design and counted
from the date of equipment commissioning;
"working medium temperature" is minimum (maximum) temperature of medium at the normal course
of technological process;

7
CU 032/2013

"design wall temperature" is the temperature at which physical-and-mechanical characteristics and


allowed pressure of the material are determined and the calculation of strength of equipment
elements is carried out;
"allowed wall temperature " is maximum (minimum) wall temperature at which equipment operation is
allowed;
"the person authorized by the manufacturer" is legal or physical body registered as individual
entrepreneur according to the legislation of the member state of Customs union and Unified economic
space on the territory of that state, which executes the functions of foreign manufacturer on the basis
of the contract with it regarding maintenance of compliance of the equipment with the requirements of
the present technical regulations and regarding responsibility for non-compliance of the equipment
with requirements of the present technical regulations;
"safety devices " are the devices intended for protection of vessels, boilers, pipelines from destruction
upon exceeding of allowed values of pressure or temperatures;
"life cycle" is the time period from the moment of release of the equipment by the manufacturer till its
disposal;
"tank" is mobile vessel constantly mounted on the frame of a railway platform, on the chassis of a car
(trailer), including that of a tanker, or on other transportation means; it is intended for transportation
and storage of gaseous, liquid and other substances;
"equipment operation" is the stage of the life cycle from the moment of equipment commissioning till
its disposal;
"equipment element" is the assembly unit of the equipment intended for execution of one of its basic
functions.
III. Marketing rules
5. The equipment is released to the market if it complies with the present technical regulations and other
technical regulations of the Customs union which apply to the given equipment and provided that it
has passed validation (confirmation) of compliance according to section VI of the present technical
regulations and other technical regulations of the Customs union which apply thereto.
6. The equipment, for which the compliance with the requirements of the present technical regulations
has not been confirmed, shall not be marked by the uniform sign of
member states of the Customs union and is not allowed to be released into trade in the market.
IV. Provision of safety of the equipment during
design (projection), manufacture (fabrication)
7. The equipment shall be designed (projected) and manufactured (produces) so that its compliance
with safety requirements was provided during its intended use, operation and maintenance.
8. For the purpose of determination of risks for the equipment one shall take into account the factors
representing the following main types of hazards:
a) presence of unprotected mobile elements;
b) vibration;
c) presence of explosive-and-flammable elements;
d) inadmissible deviations of the parameters of a structure, assembly units and safety devices
influencing safety;
e) fire, emergency situations of natural and technogenic character;
f) overheat;
g) pressure excess (working pressure does not exceed allowed value);
h) the damage related to deposition of impurities of working medium on internal surfaces of
equipment elements;
i) corrosion or other kinds of deterioration of the surface of equipment elements;
j) malfunction of safety devices and safety systems;
k) the stop of operation of auxiliary equipment;

8
CU 032/2013

l) failure of the flame in a fire chamber in the case of in-chamber fuel combustion;
m) loss of voltage at all control-and-measurement devices, remote and automatic control devices;
n) the decrease of the level of liquid working medium below minimum allowed level;
o) the increase of the level of working medium above maximum allowed level;
p) the decrease of flow rate the heat-carrier through the boiler below minimum allowed value;
q) the decrease of pressure of the heat-carrier in a boiler path below minimum allowed level;
r) the rise of the temperature of the heat-carrier at the exit from the equipment to the limiting value
specified by the manufacturer;
s) failure of direct-acting indicators of working medium level .
9. During design, risk estimation by design, experimental and examination method or by the data of
operation of similar kinds of equipment is carried out for identified kinds of hazard.
10. The equipment is classified by categories (1st, 2nd, 3rd and 4th) depending on capacity or nominal
diameter and maximum allowed working pressure according to the annex 1 of the present technical
regulations.
11. Safety of the equipment is provided by observance of safety requirements stated in the present
section and annex 2 of present technical regulations during design (projection), manufacture
(fabrication).
12. During manufacture (fabrication) of the equipment and safety devices, the manufacturer provides
their compliance with the parameters and characteristics established by design documentation, and
with the requirements of the present technical regulations.
13. The manufacturer executes the testing of the equipment provided for by design documentation.
14. Deviations from design documentation during manufacture (fabrication) of the equipment are to be
agreed with the designer (projector).
15. The equipment shall be safe during all service life if the consumer observe the measures for
maintenance of its safety specified in technical documentation.
16. Technical documentation enclosed to the equipment includes the following:
a) equipment certificate;
b) the copy of safety case;
c) general view drawing;
d) certificates of safety devices (if they are present according to design documentation);
e) calculation of capacity of safety devices (if they are present according to design documentation);
f) calculation of strength of the equipment;
g) operation manual (operation instruction);
h) the drawings, diagrams, calculations and other documentation according to the contract of
delivery.
17. Equipment certificate is the basic document for equipment identification.
The presence of equipment certificate is obligatory for the equipment to be traded on the customs
territory of the Customs union at all stages of equipment life cycle.
Equipment certificate is executed by the manufacturer.
The stamp of the manufacturer is put and the date of execution of the certificate is indicated on
equipment certificate.
18. Depending on the kind of the equipment, equipment certificate shall include the information according
to items 19 23 of the present technical regulations.
19. Pipeline certificate includes the following information:
a) the name and the address of the enterprise-owner;
b) the purpose;

9
CU 032/2013

c) the date of manufacture (fabrication);


d) working medium;
e) working parameters of the working medium: pressure, MPa (kgs/cm2 );
f) design life;
g) design operating time;
h) design number of start-ups;
i) the diagrams, drawings, certificates and other documents on manufacture (fabrication) and
installation of the pipeline.
20. Boiler certificate includes the following information (the volume of the data is specified by the
manufacturer depending on boiler type):
a) general data:
the name and the address of the manufacturer;
date of manufacture (fabrication);
type (model);
the name and the purpose;
factory number;
design service life;
design operating time of the boiler and main parts;
design number of start-ups;
geometrical sizes of the boiler and its elements;
b) technical characteristics and parameters:
design type of fuel and its combustion heat, MJ/kg (kcal/kg);
fuel consumption, m3/h (t/h);
type and the characteristics of burning installation (burners);
design, working and trial pressure, MPa (kgs/cm2);
maximum allowed hydraulic resistance of the boiler at rated output, MPa (kgf/cm2);
minimum allowed pressure at rated temperature, MPa (kgf/cm2);
rated temperature of the steam at boiler output
design temperature of overheated steam
rated temperature of the liquid at boiler input
rated and maximum temperature of the liquid at boiler output
rated, minimum and maximum allowed steam-generating capacity, t/h;
rated, minimum and maximum heat producing capability, kW;
heating surface of the boiler and main parts, m2;
capacity, m3;
3
minimum and maximum allowed liquid flow rate, m /h;
c) the data on safety devices (including type, quantity, installation site, section area, nominal
diameter, mass flow rate of steam or liquid, the size (the range) of the start of the opening);
d) the data on liquid (water) level indicators (including indicator type, quantity, and installation site);
e) the data on main fittings (including quantity, nominal diameter, rated pressure, working
parameters, a case material, an installation site);
f) the data on main equipment for measurement, managements, alarm, regulation and automatic
protection (including quantity, type (mark));

10
CU 032/2013

g) the data on pumps (including type, quantity, working parameters, type of the drive);
h) the data on basic elements of the boiler, manufactured (produced) from sheet steel (including
quantity, sizes, material, welding and heat treatment);
i) the data on boiler elements manufactured (produced) from pipes (including quantity, sizes,
material, welding and heat treatment);
j) the data on nozzles, covers, bottoms, transitions, flanges (including quantity, sizes, and material);
k) the data on heat-carrier (including name, maximum allowed temperature of usage, self-ignition
temperature in open space, hardening temperature, boiling temperature, the change (the curve)
of boiling temperatures depending on pressure, other data influencing safe operation);
l) the figures, diagrams, drawings of the boiler and its main elements and other documents
(summary sheet of factory modifications, the list of standard equipment, the specification with
indication of basic sizes of assembly units, etc.);
m) other data providing safety of boiler operation.
21. Vessel certificate includes the following information:
a) general data:
the name and the address of the manufacturer;
the date of manufacture (fabrication);
factory number;
design service life;
b) the data on technical characteristics and parameters:
working, design, and trial pressure, MPa (kgf/cm2);
working temperature of the working medium
design wall
minimum allowed negative wall temperature
working medium name;
working medium group;
the additive for corrosion (erosion compensation), mm;
capacity, m3;
the weight of empty vessel, kg;
maximum weight of filling medium, kg;
c) the data on main parts (including quantity, sizes, material, welding (soldering));
d) the data on nozzles, flanges, covers, fasteners (including quantity, sizes, and material);
e) the data on safety devices, main fittings, control-and-measuring devices, safety devices
(including quantity, nominal diameter, design pressure, material of the case, installation site);
f) the figures, diagrams, drawings of the vessel and other documents (summary sheet of factory
modifications, the list of standard equipment, the specification with indication of basic sizes of
assembly units, etc.);
g) other data providing safety of vessel operation.
22. Cylinder certificate includes the following information:
a) general data:
the name and the address of the manufacturer;
the date of manufacture (fabrication);
cylinder designation;
the medium for which the cylinder is intended;

11
CU 032/2013

factory number;
b) the data on technical characteristics and parameters:
2
working pressure, MPa (kgf/cm );
trial pressure, MPa (kgf/cm2);
basic sizes of the cylinder, the drawing of the cylinder;
capacity, l;
weight, kg;
the screw on the mouths;
the sealing of mouths;
operation temperature range
maximum number of charges;
design life from the date of manufacture (fabrication), years;
c) the requirements for transportation and storage of the cylinder;
d) the requirements for cylinder installation;
e) the requirements for cylinder operation;
f) other data providing safety of cylinder operation.
23. Fitting certificate includes the following information:
a) general data:
the name and the address of the manufacturer;
the date of manufacture (fabrication);
name, designation, and identification (factory) number;
the purpose of fittings;
the data on compliance confirmation;
b) the data on technical parameters:
nominal diameter (DN);
rated pressure (PN) or working pressure (Pp), MPa (kgf/sm);
working medium;
working medium temperature,
tightness of the shutter;
climatic modification and parameters of the medium;
the type of joining to the pipeline;
hydraulic characteristics (resistance factor, or rated output, or mass flow rate);
resistance to external impacts (if it is necessary to specify such information);
weight, kg;
reliability indicators;
safety indicators;
type of the drive and its basic technical characteristics;
c) the data on materials of main parts;
e) other data providing safety of boiler operation.
24. The manufacturer has the right to add the information reflecting design features of particular
equipment to the data specified in items 19 23 of the present technical regulations.

12
CU 032/2013

25. Safety case of the equipment is prepared at the stage of design (projection) of the equipment.
Safety case includes the analysis of risks for the equipment, and minimum necessary safety
measures.
The original of safety case of the equipment is stored by the designer (projector), and the copy is
stored by the manufacturer of the equipment and the organization maintaining the equipment.
26. The manufacturer of the equipment shall provide the equipment with operation manual (instruction).
Operation manual (instruction) is prepared at the stage of design (projection) of the equipment.
27. Operation manual (instruction) includes:
a) the data on design, principle of action, characteristics (properties) of the equipment;
b) the instructions for installation or assemblage, set-up or adjustment, maintenance and repair of
the equipment;
c) the instructions for use of the equipment and safety measures which must be observed during
equipment operation (including commissioning, intended use, maintenance, all kinds of repair,
periodic diagnostics, tests, transportation, packing, preservation and storage conditions);
d) specified indicators (specified period of storage, specified life and (or) the specified operating
time) depending on design features.
Upon the expiry of the specified indicators (specified period of storage, specified life and (or)
specified operating time) stated in operation manual (instruction), operation of the equipment is
stopped, and one decides whether it shall be repaired, disposed, or checked with establishment
of new specified indicators (specified operating time, period of storage, service life);
e) the list of critical failures, possible erroneous actions of the personnel which lead to incident or
emergency;
f) the actions of the personnel in the case of incident, critical failure or emergency;
g) the criteria of limiting conditions;
h) the instructions for decommissioning and disposal;
i) the data on qualification of maintenance personnel;
j) name, location and contact information of the manufacturer (the person authorized by the
manufacturer), the importer.
28. Operation manual (instruction) is drawn up in Russian and (in the case of presence of appropriate
requirement in the legislation of member states of the Customs union and unified economic space
(hereafter referred to as member states) in state languages of member states.
Operation manual (instruction) is executed on paper carrier, and the set of operational documents on
the electronic carrier may be enclosed. The set of the equipment of not-household purpose may be
supplied with operation manual (instruction) only on electronic carrier at the manufacturer option.
29. The equipment is marked by clear and legible inscriptions containing the following information:
a) the name and (or) designation of the type, mark, and model of the equipment;
b) the parameters and characteristics influencing safety;
c) the material from which the equipment (the elements) is (are) manufactured (produced);
d) trade mark of the manufacturer (if available);
e) factory number;
f) date of manufacture (fabrication).
30. The place of the marking is specified by the design organization and is given in operation manual
(instruction).
If the data specified in item 29 of the present technical regulations cannot be directly marked on the
equipment, then it may be specified only in operation manual (instruction) enclosed to that
equipment.

13
CU 032/2013

31. On the equipment intended for transportation of liquefied hydrocarbon gases (cylinders and tankers),
distinctive coloring and identification information are applied according to the requirements provided
for by annex 3 of the present technical regulations. In the case of coating (covering) of the specified
equipment by corrosion-resistant and thermal insulating materials, the painting over all the length may
not be made.
32. Elements and accessories of the equipment are marked according to the delivery contract. The
marking shall provide their identification.
33. Technical documentation for the equipment is stored by the manufacturer (the person authorized by
the manufacturer) during design life from the date of withdrawing from fabrication of this equipment or
termination of its manufacture.
34. The rules of equipment operation are established by the legislation of member states.
V. Provision of compliance with safety requirements
35. Compliance of the equipment with the requirements of the present technical regulations is provided
by direct observance of these requirements or by observance of the requirements of the standards
included in the list of those standards which voluntary application provide the observance of the
requirements of the present technical regulations.
36. The methods of examination (testing) and measurements of the equipment are established by the
standards included in the list of standards containing rules and methods of examination (testing) and
measurements, including the rules of sampling required for application and observance of the
requirements of the present technical regulations and validation (confirmation) of compliance of the
equipment.
VI. Validation (confirmation) of compliance of the equipment
37. The equipment released into trade on the customs territory of the Customs union is subject to
validation (confirmation) of compliance with the requirements of the present technical regulations.
38. The validation (confirmation) of compliance of the equipment with the requirements of the present
technical regulations is carried out in the form of state control (supervision) and in the form of
compliance confirmation.
39. State control (supervision) of observance of the requirements of the present technical regulations is
carried out according to the legislation of member states.
40. Confirmation of compliance of the equipment with the requirements of the present technical
regulations (hereafter referred to as compliance confirmation) is carried out by means of:
a) certification by accredited body for certification (validation (confirmation) of compliance) included
into Unified register of certification authorities and testing laboratories (centers) of the Customs
union (hereafter referred to as certification body);
b) declaration of compliance on the basis of own proofs and (or) the proofs received with
participation of certification body or accredited test laboratory (centre), included into Uniform
register of bodies on certification and test laboratories (centers) of the Customs union (hereafter
referred to as accredited test laboratory).
41. Compliance confirmation is carried out according to the certification and declaration schemes
established by the present technical regulations.
42. Declaring of compliance of the equipment with the requirements of the present technical regulations
is carried out by the applicant for the equipment of 1st and 2nd categories, and also for the
equipment of any category which is reworked with the application of one-piece connections at
operation site.
43. Certification is carried out for the equipment of the 3rd and 4th categories.
44. The single document of confirmation of compliance of the equipment with the requirements of the
present technical regulations is either declaration of compliance, or certificate of compliance.
45. At execution of confirmation of compliance, the applicant forms the set of documents for the
equipment which includes:
a) safety case;
b) equipment certificate;

14
CU 032/2013

c) operation manual (instruction);


d) design documentation;
e) results of strength calculations and calculations of the output of safety devices (if they are present
according to the project);
f) process regulations and data on technological process (the data about applied materials, half-
finished products, complementary products, welding materials, about the methods and
parameters of welding modes and thermal processing, about methods and results of non-
destructive testing);
g) the data on executed tests (measurements);
h) the reports of equipment tests carried out by the manufacturer, manufacturer-authorized body
and (or) accredited test laboratory;
i) the document of confirmation of characteristics of the materials and complementary products (if
available);
j) certificates of compliance, declaration of compliance or test reports regarding the materials,
complementary products (if available);
k) the list of the standards specified in section V of the present technical regulations which have
been applied for manufacture (fabrication) of the equipment (in the case of their application by the
manufacturer);
l) the documents confirming qualification of the experts and the personnel of the manufacturer;
m) other documents which directly or indirectly confirm the compliance of the equipment with the
requirements of the present technical regulations (if available).
46. Declaration of compliance of the equipment with the requirements of the present technical regulations
is carried out according to the following schemes:
a) The scheme 1d is applied for batch-produced equipment of the 1st and 2nd categories; the
applicant forms the set of the documents specified in item 45 of the present technical
regulations, carries out industrial inspection and takes the measures for fabrication process to
provide compliance of the equipment with the requirements of the present technical regulations,
executes the tests of the samples in test laboratory or accredited test laboratory, accepts and
registers the declaration of compliance;
b) the scheme 2d is applied for the batch of the equipment (individual product) of the 1st and 2nd
categories; the applicant forms the set of the documents specified in item 45 of the present
technical regulations, executes the tests of the samples in test laboratory or accredited test
laboratory, accepts and registers the declaration of compliance;
c) The scheme 3d is applied for batch-produced equipment elements of 1st and 2nd categories
and complementary products of the equipment of 1st and 2nd categories; the applicant forms
the set of the documents specified in item 45 of the present technical regulations, carries out
industrial inspection and takes the measures for fabrication process to provide compliance of
equipment elements and complementary products with the requirements of the present
technical regulations, executes the tests of samples in accredited test laboratory, accepts and
registers the declaration of compliance;
d) The scheme 4d is applied for a batch of equipment elements of the 1st and 2nd categories and
complementary products of the equipment of the 1st and 2nd categories; the applicant forms
the set of the documents specified in item 45 of the present technical regulations, executes the
tests of samples in accredited test laboratory, accepts and registers the declaration of
compliance;
e) The scheme 5d is applied for the equipment of the 1st, 2nd, 3rd and 4th categories, which is
reworked with the application of one-piece connections at operation site in the following cases:
full testing before the installation of the equipment on the site of its operation is impossible;
during design (projection) and manufacture (fabrication) of the equipment, the standards
specified in point 36 of the present technical regulations were not applied, and for innovative
equipment, too. In the case of application of scheme 5d, the applicant forms the set of the
documents specified in item 45 of the present technical regulations, carries out industrial
inspection, takes the measures for fabrication process to provide compliance of equipment with
15
CU 032/2013

the requirements of the present technical regulations, and sends to certification body the
application for execution of type test of the equipment;
certification body executes type test of the equipment taking into account the documents
received from the applicant. If the applicant has not applied the standards specified in item 36
of the present technical regulations, then certification body estimates the possibility of
replacement of the requirements of these standards by declared requirements. Type test of the
equipment depending on the documents presented by the applicant is carried out by one of
following ways:
examination of the specimen as representative sample of all equipment which would be
manufactured then;
examination of submitted documents, testing the sample or basic (critical) components of
the equipment;
in the case of positive results of type tests of the equipment, certification body draws up
and issues to the applicant the certificate for equipment type according to the uniform form
approved by the solution of the Eurasian economic commission. The above certificate is an
integral part of the declaration of compliance. The declared requirements for the equipment
contained in it, recognized as sufficient evidence of compliance of the equipment with the
requirements of the present technical regulations, are used during the checks of
observance of the requirements of the present technical regulations executed by the bodies
of state control (supervision);
the applicant accepts the declaration of compliance and executes its registration according
to the established order.
47. When compliance is declared according to the schemes 1d, 3d and 5d, the applicants may be legal
or physical bodies registered according to the legislation of the member states on its territory as
individual entrepreneurs which are manufacturers or the bodies authorized by the manufacturers.
When compliance is declared according to the schemes 2d and 4d, the applicants may be legal or
physical bodies registered according to the legislation of the member states on its territory as
individual entrepreneurs which are manufacturers, sellers or the bodies authorized by the
manufacturers.
48. The documents specified in item 45 of the present technical regulations, and also the standards
specified in section V of the present technical regulations are used as evidentiary materials which are
the basis for acceptance of the declaration of compliance on the basis of own proofs.
49. Equipment test reports can be used as evidentiary materials which are the basis for acceptance of
the declaration of compliance on the basis of own proofs, if the values of the indicators contained in
those reports confirm compliance of the declared equipment with all applicable requirements of the
present technical regulations.
50. The declaration of compliance is drawn up according to the uniform form of the declaration of
compliance with the requirements of the technical regulations of the Customs union and the rules of
its registration approved by the Decision of the Board of the Eurasian economic commission from the
th
25 of December, 2012, N 293.
51. The declaration of compliance is subject to registration according to the established order. Action of
the declaration of compliance begins from the date of its registration in the Uniform register of issued
certificates of compliance and registered declarations of compliance. Period of validity of the
declaration of compliance of batch-produced equipment is not over 5 years. For a batch of the
equipment (individual product), the period of validity of the declaration of compliance is not
established.
The declaration of compliance of the batch of the equipment with the requirements of the present
technical regulations is valid only for the equipment from particular batch.
52. Equipment certification is carried out according to the following schemes:
a) the applied for batch-produced equipment; in this case:
the applicant forms the set of documents specified in item 45 of the present technical regulations
and submits the application for certification to certification body;
certification body executes sampling for the testing;

16
CU 032/2013

accredited test laboratory executes testing of equipment samples;


certification body carries out the audit of fabrication facilities of the manufacturer and the results
of executed tests of equipment samples and, if the results are positive, issues the certificate of
compliance to the applicant;
certification body carries out inspection control over the certificated equipment by means of
testing the samples in the accredited test laboratory and (or) audit of fabrication facilities ;
b) applied for the batch of equipment; in this case:
the applicant forms the set of the documents specified in item 45 of the present technical
regulations and submits the application for certification to certification body;
certification body or accredited test laboratory executes sampling for
the testing;
accredited test laboratory executes the tests of equipment samples;
certification body carries out the analysis of the results of testing equipment samples and, in the
case of positive results, issues the certificate of compliance to the applicant;
c) the applied for a individual product; in this case:
the applicant forms the set of the documents specified in item 45 of the present technical
regulations and submits the application for certification to certification body which shall include
identification signs of the individual product;
certification body informs the applicant about the decision on application; the decision includes
the conditions of certification execution;
accredited test laboratory on the instructions of certification body executes the testing of
individual product;
certification body carries out the analysis of the results of testing of individual product and issues
the certificate of compliance to the applicant in the case of positive results;
d) the applied for the equipment intended for launching into batch and mass fabrication,
and also in the case of planning of equipment modifications; in this case:
the applicant forms the set of the documents specified in item 45 of the present technical
regulations and submits the application for certification to certification body;
certification body executes type test of the equipment by one of following ways:
the examination of equipment sample for planned fabrication as typical representative of all
future products;
the analysis of technical documentation, testing of equipment sample or basic components.
the results of the examination are documented by the conclusion in which the certification body
assess the compliance of equipment type with the established requirements.
The audit of fabrication facilities is carried out by certification body.
The results of the analysis are documented by the report.
In the case of positive results of type test of the equipment and of the audit of fabrication facilities,
certification body draws up the certificate of compliance and gives it to the applicant.
53. Certification body carries out inspection control of certificated equipment during all the period of
validity of the certificate by means of testing the samples of the equipment in accredited test
laboratory and (or) audit of fabrication facilities . In the case of results of inspection control, validity of
the certificate of compliance is considered to be confirmed; this shall be stated in the inspection
control report. In the case negative results of inspection control the certification body takes one of
following solutions:
a) suspend the certificate of compliance;
b) withdraw the certificate of compliance.
54. When the design (structure) of the equipment or technology of its manufacture is modified, and that
modification may affect the compliance of the equipment with the requirements of the present
technical regulations, the applicant notifies certification body in writing in advance about that

17
CU 032/2013

modification, and certification body decides on the necessity of executing new tests and (or) audit of
fabrication facilities of the equipment.
55. In the case of certification according to schemes , the applicants may be legal or physical
bodies registered according to the legislation of the member states on its territory as individual
entrepreneurs which are manufacturers or the bodies authorized by the manufacturers.
In the case of certification according to schemes , the applicants may be legal or physical
bodies registered according to the legislation of the member states on its territory as individual
entrepreneurs which are manufacturers, sellers or the bodies authorized by the manufacturers.
56. The applicant may address the application for certification to any certification body having appropriate
scope of accreditation.
57. The certificate of compliance is drawn up according to the uniform form of the certificate of
compliance with the requirements of technical regulations of the Customs union and the rules of its
registration approved by the decision of the Board of Eurasian economic commission from the 25th of
December, 2012 N 293.
58. The period of validity of the certificate of compliance of the equipment is:
a) when schemes are used 5 years;
b) when scheme during specified life or specified operating time.
59. Documents and the materials confirming the results of the certification are stored by certification body
which has issued the certificate of compliance during design life of the equipment which has passed
the procedure of certification.
60. Upon the request of consumers (purchasers) and (or) interested persons, the copy of the declaration
of compliance or certificate of compliance shall be provided to them by the manufacturer (the person
authorized by the manufacturer) or by the seller with no charge.
VII. Equipment marking by the
member states of the Customs union
61. The equipment which complies with the requirements of the present technical regulations and has
passed the procedure of confirmation of compliance is marked by the
in the market of member states of the Customs union.
62. The marking by the
union is made before the equipment is released into trade in this market.
63. The ember states of the Customs union is applied
on each unit of the equipment by any method providing accurate and clear image during all service
life of the equipment, and is indicated in operational documents enclosed to the equipment, too.
64. The marking of the equipment by
of the Customs union indicates its compliance with the requirements of all technical regulations of the
Customs union which apply to this equipment and providing for application of the uniform sign of
.
VIII. Disclaimer statement
65. Authorized bodies of member states undertake all measures for restriction and interdiction of release
into trade of the equipment in the customs territory of the Customs union, and also for withdrawal
from the market of the equipment which do not comply with the requirements of the present technical
regulations.
In this case, authorized body of one member state is obliged to notify the authorized bodies of other
member states about the decision taken with the indication of the reason of taking that decision and
provision of the evidence explaining the necessity of execution of that measure.

18
CU 032/2013

Annex No. 1
to Technical regulations of the Customs union
"On the safety of excess pressure equipment"
( 032/2013)
Annex 1

CLASSIFICATION OF THE EQUIPMENT BY HAZARD CATEGORIES


1. Equipment categories are defined according to tables 1 9 of the present documents.
Safety devices are classified to the 4th category, except for the safety devices manufactured
(produced) for particular equipment which may be classified to the same category as the equipment
for which they are devices manufactured (produced).
2. The category of the equipment intended for operation with design temperature above transition
temperature of the creep of metal increases by 1 (except the for the 4th category).
3. Transition temperature of the creep is:
low-alloy silica manganiferous steels;
C for low-alloy chrome molybdenum and chrome molybdenum vanadium steels;
C for alloyed high-chromium steels of martensitic class and austenitic steels;
nickel-iron-based nickel-based alloys.
Table 1 The categories of the vessels intended for gases and used for working media of
group 1
Category of the Capacity of the The product of value of maximum Maximum allowed working
equipment equipment (m3) allowed working pressure by the pressure (MPa)
value of capacity (MPa m3)
1 2 3 4
1st Over 0,001 Over 0,0025 to 0,005 inclusive Over 0,05
2nd Over 0,001 Over 0,005 to 0,02 inclusive Over 0,05
3rd Over 0,0001 to Not standardized Over 20 to 100 inclusive
0,001 inclusive
Over 0,001 Over 0,02 to 0,1 inclusive Over 0,05
4th Over 0,0001 to Not standardized Over 100
0,001 inclusive
Over 0,001 Over 0,1 Over 0,05

19
CU 032/2013

Table 2 The categories of the vessels intended for gases and used for working media of
group 2
Category of the Capacity of the The product of value of maximum Maximum allowed working
3
equipment equipment (m ) allowed working pressure by the pressure (MPa)
m 3)
1 2 3 4
1st Over 0,001 Over 0,005 to 0,02 inclusive Over 0,05
2nd Over 0,001 Over 0,02 to 0,1 inclusive Over 0,05
3rd Over 0,0001 to Not standardized Over 100 to 300 inclusive
0,001 inclusive
Over 0,001 to 1 Over 0,1 to 0,3 inclusive Over 0,05
inclusive
Over 1 Not standardized Over 0,05 to 0,4 inclusive
4th Over 0,0001 to Not standardized Over 300
0,001 inclusive
Over 0,001 to 1 Over 0,3 Over 0,4
inclusive
Over 1 Not standardized Over 0,4

Table 3 The categories of the vessels intended for liquids and used for working media of group 1
Category of the Capacity of the The product of value of maximum Maximum allowed working
equipment equipment (m3) allowed working pressure by the pressure (MPa)
m 3)
1 2 3 4
1st Over 0,01 Over 0,02 Over 0,05 to 1 inclusive
2nd Over 0,001 Over 0,02 Over 1 to 50 inclusive
Over 0,0001 to Not standardized Over 50
0,001 inclusive
3rd Over 0,001 Not standardized Over 50

Table 4 The categories of the vessels intended for liquids and used for working media of group 2
Category of the Capacity of the The product of value of maximum Maximum allowed working
equipment equipment (m3) allowed working pressure by the pressure (MPa)
m 3)
1 2 3 4
1st Over 0,01 Over 1 Over 1 to 50 inclusive
2nd Over 0,0001 to Not standardized Over 100
0,01 inclusive
Over 0,01 Over 1 Over 50

20
CU 032/2013

Table 5 The categories of steam, water-heating boilers and vessels with fire heating
Category of the Capacity of the Product of value of maximum allowed Maximum allowed
equipment working pressure upon value of capacity working pressure
3
(MPa m ) (MPa)
1 2 3 4
1st Over 0,002 to 0,1 To 0,005 inclusive Over 0,05
inclusive
2nd Over 0,002 to 0,4 Over 0,005 to 0,02 inclusive Over 0,05 to 3,2
inclusive inclusive
3rd Over 0,002 to 1 Over 0,02 to 0,3 inclusive Over 0,05 to 3,2
inclusive inclusive
4th Over 0,002 to Not standardized Over 3,2
0,01 inclusive
Over 0,01 to 1 Over 0,3 Over 0,3
inclusive
Over 1 Not standardized Over 0,05

Table 6 The categories of the pipelines intended for gases and steams and used for working
media of group 1
Category of the Nominal Product of value of maximum allowed Maximum allowed working
equipment diameter (mm) working pressure upon value of pressure (MPa)
nominal diameter (MPa
1 2 3 4
1st Over 25 to Not standardized Over 0,05 to 1 inclusive
100 inclusive
Over 25 to To 100 inclusive Over 1 to 3,5 inclusive
100 inclusive
2nd Over 100 to Not standardized Over 0,05 to 1 inclusive
350 inclusive
Over 25 to Over 100 to 350 inclusive Over 1 to 3,5 inclusive
350 inclusive
Over 25 to Not standardized Over 3,5
100 inclusive
3rd Over 350 Not standardized Over 0,05 to 1 inclusive
Over 100 to Over 350 Over 1 to 3,5 inclusive
350 inclusive
Over 100 Not standardized Over 3,5

21
CU 032/2013

Table 7 The categories of the pipelines intended for gases and steams and used for working
media of group 2
Category of the Nominal diameter Product of value of maximum allowed Maximum allowed
equipment (mm) working pressure upon value of working pressure
(MPa)
1 2 3 4
1st Over 32 Over 0,05 to 3,2
inclusive
From 32 to 100 Not standardized Over 3,2
inclusive
2nd Over 100 Over 350 to 500 inclusive Over 0,05 to 3,2
inclusive
Over 100 to 250 Not standardized Over 3,2
inclusive
3rd Over 250 Over 3,2
Over 250 Over 500 Over 0,05 to 3,2
inclusive

Table 8 The categories of the pipelines intended for liquids and used for working media of
group 1
Category of the Nominal Product of value of maximum allowed Maximum allowed
equipment diameter (mm) working pressure upon value of working pressure
(MPa)
1 2 3 4
1st Over 25 Over 200 Over 0,05 to 1
inclusive
2nd Over 25 Over 200 Over 1 to 8 inclusive
Over 25 Over 350 Over 8 to 50 inclusive
3rd Over 25 Not standardized Over 50

Table 9 The categories of the pipelines intended for liquids and used for working media of
group 2
Category of the Nominal Product of value of maximum allowed Maximum allowed
equipment diameter (mm) working pressure upon value of working pressure
(MPa)
1 2 3 4
1st Over 200 Over 500 Over 1 to 50 inclusive
2nd Over 200 Not standardized Over 50

22
CU 032/2013

Annex No. 2
to Technical regulations of the Customs union
"On the safety of excess pressure equipment"
( 032/2013)
Annex 2

REQUIREMENTS FOR EQUIPMENT SAFETY DURING DESIGN (PROJECTION),


MANUFACTURE (FABRICATION)
1. Design (projection) of the equipment considers its strength taking into account predicted loadings
which can arise in the course of its operation, transportation, carriage, installation and predicted
deviations from such loadings. The following factors are considered:
a) the loadings acting on internal and external surfaces of the equipment;
b) ambient temperature and working medium temperature;
c) static pressure under operating conditions and the pressure under the conditions of testing
from the weight of equipment contents;
d) inertial loads during the movement, wind and seismic impacts;
e) reaction forces (counteractions) which are transferred from supports, fasteners, and
pipelines;
f) fatigue at variable loadings;
g) erosive and corrosive attacks of medium, including erosion-and-corrosion deterioration;
h) chemical reactions due to the instability of processed media and technological process;
i) the changes of mechanical properties of the materials while in service.
2. The equipment shall exclude the possibility of hurting in the following cases:
a) closing and opening of the hatches or the units of control of equipment monitoring;
b) performance of the technological operations related with placing of the equipment under
pressure, putting the equipment into operation mode, and with pressure relief;
c) performance of the technological operations related with the risk of falling of the personnel
from a working platform intended for equipment maintenance;
d) occurrence of excess pressure or vacuum inside the equipment when people are at inside
this equipment;
e) occurrence of inadmissible temperature of external surfaces;
f) decomposition of unstable working media.
3. The equipment is projected taking into account the possibility of executing the checks necessary for
confirmation of its compliance with safety requirements.
4. The project of the equipment defines its borders (limits).
5. Depending on the purpose of the equipment, its project shall provide for its fitting with the following:
a) safety devices;
b) the means of measurement of the level of liquid working medium;
c) pressure measuring means;
d) the means of measuring working medium temperature;
e) shut-off and control valves;
f) feed appliances;
g) the devices for control of thermal displacements.
6. Equipment design shall provide safe access of the personnel to safety devices and the devices of
control of the parameters of working medium of the equipment.

23
CU 032/2013

7. The project of the equipment shall provide for the application of the following:
a) control and measuring means which error under operating conditions does not exceed
maximum permissible deviation of control parameter;
b) measuring means according to equipment service conditions.
8. The project shall provide fitting the equipment with the devices of media drainage and air removal
which allows for:
a) avoiding hydraulic impact, vacuum destruction, corrosion or occurrence of uncontrollable
chemical reactions (processes of operation and tests shall be considered then);
b) providing safe clearing, control and maintenance.
9. The project of the equipment shall provide for assurance of safety of the processes of filling or
emptying of the equipment in the following cases:
a) overflow or pressure excess, and also when the equipment has to operate under pressure
which arises periodically during equipment filling;
b) uncontrollable unloading of the working medium during emptying of the equipment;
c) the danger related with connection to a source of pressure and disconnection from it during
filling or emptying of the equipment.
10. For the purpose of prevention of corrosion, erosion-and-corrosion deterioration or other chemical
impact of the working medium while in service and protection of the equipment against them the
following is provided:
a) minimization of these impacts by means of the design;
b) the possibility of replacement of equipment elements which may be subject to that impact.
11. The equipment is equipped with the devices providing minimization of the consequences in the
case of external ignition, if necessary.
It is necessary to provide additional illumination for safe operation of the equipment. Internal parts
and areas of the equipment requiring frequent examination, adjustment and maintenance, shall
have safety-providing illumination.
12. In the equipment for which there is a hazard of overheat, the factors resulting from the overheat of
the equipment and reducing its safety are excluded or reduced to the minimum. For these
purposes, the following is provided for:
a) the devices for restriction of heat supply or removal, restriction of working medium level for
the purpose of exclusion of local or general overheat of the metal;
b) the places of sampling of the working medium for the purpose of estimation of its impact on
the formation of deposits of impurities and (or) corrosion damage;
c) the measures for prevention of the damage related to deposits of impurities;
d) the devices for safe removal of residual or excessive heat after switching-off the equipment;
e) the measures for exclusion of formation of fire-and-explosion dangerous mixes, and also
flame distribution (flame arresters, flame cut-off devices, hydraulic shutters).
13. The estimation of equipment strength is based on calculation methods or on experimental test
results without calculation, which are applied when the product of the value of maximum allowed
3
working pressure by the value of capacity of the equipment is less than 0,6 MPa m or when the
product of the value of maximum allowed working pressure by the value of nominal diameter is less
than 300 MPa
14. For calculation of equipment strength, the following calculation methods are applied; these methods
may supplement each other:
a) by means of the formulas given in the rules of calculation of equipment strength;
b) on the basis of the numerical analysis of stress condition;
c) on the basis of consideration of limiting conditions and mechanics of destruction.

24
CU 032/2013

15. Strength calculation accounts for all possible loads and factors and probability of their simultaneous
occurrence, all possible mechanisms of destruction (ductile or brittle, creep of materials, fatigue of
materials, corrosion cracking) according to the purpose of the equipment and the processes of its
operation.
16. The following conditions are required for maintenance of equipment strength:
a) the value of design pressure shall be not less maximum allowed working pressure for which
the equipment is intended. The value of design pressure considers static pressure and
dynamic loads of the working medium, increase of pressure due to instability of working
media and technological processes. When the equipment consist of several chambers
operating at different values of pressure, design pressure is taken to be either each pressure
value separately, or the pressure which requires larger thickness of the wall of equipment
element being calculated;
b) design temperatures provide safe limits of application of the materials and the equipment;
c) the equipment and the materials from which the equipment is manufactured (produced) are
applied in the range of design temperatures;
d) all possible combinations of pressure, temperature and other loads which arise while in
service, transportations, carriage and testing of the equipment, are considered.
17. Strength calculation considers the following characteristics of the materials:
a) yield point, offset yield strength at 0,2 percent and 1 percent of residual deformation at
normal and design temperatures;
b) ultimate tensile strength at normal and design temperatures;
c) long-term strength or creep strength at design temperature and specified number of hours;
d) the characteristic of low-cycle strength or fatigue at specified number of cycles and pressure
level;
e) modulus of elongation (Young modulus) at normal and design temperatures;
f) the values of plastic deformation at the rupture of standard samples;
g) impact strength;
h) fracture toughness (stress intensity factor).
18. Strength calculations are carried out taking into account strength factors of welded connections
which values depend on welded materials, welding (soldering) procedure, connection form, the
method and the extent of non-destructive testing and the processes of equipment operation.
Equipment elements working under external pressure or those exposed to compression stress from
other loads shall be checked for form stability.
19. Equipment strength calculation takes into account forecasted deviations of working parameters in
the course of equipment operation, allowed inaccuracies of manufacture (fabrication), and possible
deviations of mechanical characteristics of applied materials.
20. Strength calculation provides safety factor of the equipment which is considered at determination of
allowed pressure.
21. Allowed pressure at strength calculation by maximum loads of the equipment operating under static
loads is determined according to following formulas:
a) For plastic carbonaceous and low-alloy, ferritic, austenitic-ferritic- martensite steels and
nickel-iron-based alloys:

,
where:
is allowed pressure at strength calculation by maximum loads of the equipment operating
under static loads;
Re/t is the minimum value of yield point at the maximum allowed temperature;

25
CU 032/2013

RP0,2/t is the minimum value of offset yield strength at 0,2 percent of residual deformation and
maximum allowed temperature;
Rm is the minimum value of ultimate strength at the

R m/10n n
is the average value of long-term strength during 10 hours at maximum allowed
temperature;

R P1/10n
is the average value of 1 percent creep strength during 10n hours at maximum
allowed temperature;
b) For austenitic chrome-nickel steels, aluminum, copper and their alloys:

R P1/t R m/t R m/10n R P1/10n


= min ; ; ;
1,5 3 1,5 1
,
where:
RP1/t is the minimum value of offset yield strength at 1 percent of residual deformation and
maximum allowed temperature;
Rm/t is the minimum value of ultimate strength at maximum allowed temperature;
c) for aluminum cast alloys:
R m/t
=
7 ;
d) for the titan and titanic alloys:
R m/t
=
3 ;
e) for rolled sheet and rolled pipes from the titan and titanic alloys:
R m/t
=
2,6 .
22. It is allowed to determine the allowed pressure for austenitic steels by the following formula:
R P0,2/t
=
1,3 .

23. For steel castings, the value of allowed pressure determined by the formulas specified in items 21
and 22 of the present requirements, are multiplied by 0,8 if the casting have passed continuous
non-destructive testing, or by 0,7 if the castings have not passed continuous non-destructive
testing.
24. When there is no data about yield point and long-term strength for aluminum, copper and their
alloys, allowed pressure is determined by the following formula:
R m/t
=
3,5 .

25. During design (projection), manufacture (fabrication) of the equipment from nonmetallic materials,
the values of ultimate strength and rupture modulus of elasticity of nonmetallic materials
correspond to the values specified in design documentation, they are the following:
a) for ugleroving-based composite material:
ultimate strength not less than 160 kgf/mm2;
module of elasticity E not less than 11 000 kgf/mm2;
b) for organovit-based composite material:
not less than 170 kgf/mm2;

26
CU 032/2013

module of elasticity E not less than 6 500 kgf/mm2;


c) for stekloroving-based composite material:
2
not less than 90 kgf/mm ;
module of elasticity E not less than 5 000 kgf/mm2.
26. Thermoplastic or thermosetting plastic polymeric materials may be used as binding agent in the
equipment.
Curing (polymerization) temperature of the binding agent shall be below softening temperature of
the material of nonmetallic binding.
Softening temperature of the material shall be not below
27. Welded connections shall not have external or internal defects (damage) which can affect safety of
the equipment. The minimum values of mechanical characteristics of welded connections of the
equipment shall be not below the minimum values of mechanical characteristics of the materials
being connected.
28. Incoming inspection of welded connections is carried out by the manufacturer of the equipment.
Methods of non-destructive testing and its extent are specified by the developer of the project of the
equipment keeping in mind the necessity of more exact and full detection of inadmissible defects
taking into account the particularities of the properties of the materials and are specified in design
documentation of the equipment.
29. When the strength of welded connections of equipment elements is calculated, the value of allowed
pressure is multiplied by strength factor of welded joints The value of strength factor of
welded joints is specified at calculation of strength of the equipment depending on the material,
extent of inspection, welding procedure and welded joint design.
30. For maximum stresses arising in the places of edge effect or stress concentration determined on
the basis of the numerical analysis, safety factor factors are established depending on mechanical
characteristics of applied materials and the kind of tension condition.
31. Experimental tests for strength of the equipment are carried out on the specimen. The possibility of
observation of critical zones of the equipment by means of control and measuring devices which
are capable of authentic registration of deformation and stresses is provided during the tests.
32. The program of experimental tests includes the following:
a) pressure tests for tightness and strength for confirmation of the absence of a leak of working
medium or residual deformations exceeding allowed values;
b) the tests for creep and fatigue of the materials which are carried out taking into account the
processes of equipment operation;
c) additional tests which consider the impacts of other factors and are carried out if necessary.
33. Design (projection) of the equipment establishes technical operational characteristics which
minimize the possibility of occurrence of incident of emergency at its operation.
34. The equipment is manufactured (fabricated) from the materials and half-finished products provided
for by design documentation and providing its compliance with safety requirements during all
service life.
35. The equipment is manufactured (fabricated) from the materials and half-finished products which
bear the marking (without damage) provided for by the contract of delivery; that marking provide the
possibility of identification with the data from manufacturer documentation for the materials or
half-finished products.
36. Manufacturer shall remain on sheets, plates, pipes and forgings used for equipment
manufacture (fabrication). If half-finished products are cut into patterns then each pattern shall be
marked with identical marking by the method which has been applied for application of the marking
by the manufacturer of the materials.
37. When materials and (or) half-finished products for manufacture (fabrication) of the equipment are
chosen it is necessary to:
a) determine the indicators for design calculations, and the basic characteristics of materials
and their processability;

27
CU 032/2013

b) state the data about the materials applied at manufacture (fabrication) of the equipment in
technical documentation.
38. The materials which are used for equipment manufacture (fabrication) shall:
a) have the properties (plasticity, strength) which allow to use them while in service and to
maintain test conditions for the equipment. When a material is chosen its brittleness or crack
resistance is considered. When brittle material is used the measures for exclusion of brittle
destruction (increase of safety factor) are taken;
b) have chemical resistance to the working medium for which the equipment is intended. The
changes chemical and physical properties of the materials during all specified life or
specified operating time shall not lead to the failure of its safe operation;
c) be suitable for the kinds of processing which are provided for ;
d) be chosen so that when they are connected to each other, the strength of the equipment was
provided during equipment service life.
39. The material applied for the equipment is considered to be plastic if tension test gives its relative
elongation after the rupture not less than 14 percent, and the impact strength specified on the
samples with the concentrator of type KCV (with a V-shaped cut), is not less than 27 J/cm2 at the
allowed temperature.
40. When the characteristics of the material change or residual stresses arise during manufacture
(fabrication), and these stresses impact the safety of the equipment, then thermal processing of the
equipment is carried out. The kind of thermal processing of the equipment and its modes are
specified by the developer of the project of the equipment.
41. During manufacture (fabrication) of the equipment and safety devices, the manufacturer provides
their compliance with the characteristics and parameters provided for by design documentation,
according to safety requirements of the technical regulations of the Customs union "On the safety
of excess pressure equipment" (CU TR 032/2013) taking into account applied technological
processes and control system.
42. When the parts are manufactured (fabricated) by rolling, stamping, and chamfering, change of
mechanical characteristics of materials, damage, cracks and other defects which can impact
equipment safety are not allowed.
43. The elements of the equipment being assembled shall provide equipment safety and comply with
its purpose. All one-piece or welded connections of equipment elements shall be accessible for
non-destructive testing.
44. The equipment supplied with quick-detachable covers shall have the devices excluding the
possibility of its switching to under-pressure state at incomplete closing of the cover, and opening of
the cover in the case of excess pressure in the equipment.
45. Boilers are equipped with safety devices providing automatic switching-off of a boiler or its
elements in the case of inadmissible deviations from design modes of operation.
46. The equipment element, which internal volume is limited by shut-off valve and pressure in which
may raise above allowed value is equipped with safety devices automatically preventing increase of
pressure above the allowed value by means of release of working medium into atmosphere or
exhaust system.
47. The following devices are used as safety devices:
a) lever-operated direct-acting weighted safety valves;
b) spring direct-acting safety valves;
c) impulse safety devices consisting of impulse valve and main safety valve;
d) burst-diaphragm safety devices (diaphragm safety devices).
48. Safety devices are placed in the places accessible for their service.
49. Discharging pipelines of safety devices and impulse lines of impulse safety devices in the places of
possible condensate formation are equipped with drainage pipelines for condensate removal.
Installation of shut-off valves or other valves on drainage pipelines is not allowed. The medium
coming out of safety devices and drainages is taken away into a safe place. Discharge explosive

28
CU 032/2013

and flammable, technological and toxic media of group 1 are directed either to the closed systems
for further disposal, or into systems of the organized burning, or into atmosphere for the gases of
the density 0,8 and less relative to the air.
Combination of wastes containing substances which are capable to form explosive mixes or
unstable connections at mixing is forbidden.
50. The design of connecting pipelines of safety devices (supply, discharge away and drainage) shall
exclude the possibility of freezing of working medium in them.
When several safety devices are installed on one branch pipe or pipeline, the area of the cross-
section of the branch pipe or the pipeline shall be not less than 1,25 of total area of the section of
safety valves installed on it. When the section of connecting pipeline of the length over 1000 mm is
determined, the value of its linear resistance (pressure loss) is considered.
51. Lever-operated weighted safety valve or spring safety valve are equipped with the device for the
fault check of their operation during equipment operation by forced opening.
Impulse safety valve is equipped with the device allowing forced remote opening of safety valve by
means of control panel.
The design of spring safety valves shall exclude the possibility of spring tension above the value
established by the setting of actuation at specified pressure. The springs of safety valves are
protected from inadmissible heating or cooling, and from direct impact of working medium.
52. Feeding connecting pipeline of the equipment intended for working pressure which is less than the
pressure of feed source is equipped with automatic reducing device with a manometer and safety
valve installed on the side of smaller pressure after reducing device.
Pressure-reducing cooling devices provide automatic temperature control. In the case of installation
of a loop line (bypass) it is also equipped with reducing device.
53. For a group of vessels operating at the same pressure, installation of 1 reducing device with a
manometer and safety valve on common feeding connecting pipeline before the first branch to one
of the vessels is allowed. In this case, safety devices on vessels may not be installed if the
possibility of pressure increase in those vessels is excluded.
If automatic reducing device cannot operate reliably due to physical properties of working medium,
the installation of flow-rate regulator is allowed; protection against pressure increase is to be
provided for then.
54. The number of safety valves, their dimensions and output are specified so that in the equipment
there was no excess pressure exceeding maximum allowed working pressure by:
a) more than 0,05 MPa for the vessels in which excess pressure is less than 0,3 MPa;
b) 15 percent for the vessels in which excess pressure is 0,3 to 6 MPa inclusive;
c) 10 percent for the vessels in which excess pressure is over 6 MPa.
55. At operating safety valves, allowed excess pressure in a vessel is not over by 25 percent from the
maximum allowed working pressure provided that this excess pressure is provided for by vessel
operation manual (instruction).
56. Safety valves shall provide protection of boilers, steam superheaters, economizers and pipelines
from excess pressure more than by 10 percent from maximum allowed working pressure. Excess
pressure at full opening of safety valves more than by 10 percents from maximum allowed working
pressure is allowed if it is provided for by strength calculation the boiler, steam superheater,
economizer and pipeline.
57. On steam boilers with working pressure over 4 MPa (except for mobile boilers and boilers with
steam-generating capacity less than 35 t/h), only impulse safety valves are installed. On mobile
boiler plants, installation of lever-operated weighted safety valves is not allowed.
58. The valves shall be installed on each steam and water-heating boilers and steam superheater
disconnectable with respect to working medium. Their number and the places of their installation
are specified during design (projection).
Total output of safety devices installed on boilers shall be not less than rated output of that
equipment.

29
CU 032/2013

59. The output of safety valves is proved by appropriate tests of pilot specimen of the safety valve of
the given design which are carried out by its manufacturer, and is indicated in equipment certificate.
60. Safety devices on steam and water-heating boilers are installed on branch pipes or the pipelines
directly attached to the boilers, as follows:
a) on steam boilers with natural circulation without steam superheater on the upper drum or
steam dome;
b) on steam direct-flow boilers, and on the boilers with forced circulation on outlet collectors
or outlet steam line;
c) on water-heating boilers on outlet collectors or on the drum;
d) on intermediate steam superheaters, the installation of all safety devices of steam
superheater from the side of steam input is possible;
e) in disconnectable water economizers not less than 1 safety device per water output and
input .
61. When a boiler has fixed steam superheater, the part of safety valves with the output not less than
50 percent of the rated output of the boiler is installed at outlet collector of steam superheater.
62. On steam boilers with working pressure over 4 MPa, impulse direct-acting safety valves are
installed on outlet collector of fixed steam superheater or on steam line before main shut-off
valves; in this case, for 50 percent of valves (with respect to total output) of drum-type boilers,
steam extraction for the impulses is carried out from boiler drum.
In the case of odd number of identical valves, steam extraction for the impulses from the drum of
not less than for one-third, but not over than for one-half of the valves installed on steam boiler is
allowed. On block installations, when safety valves are placed on steam line directly at the turbines,
it is allowed to use superheated steam for impulses of all safety valves; in this case, for 50 percents
of valves, additional electric impulse from the contact manometer connected to boiler drum is fed.
In the case of odd number of identical safety valves it is allowed to feed additional electric impulse
from the contact manometer connected to boiler drum, not less than for one-third, but not over than
for one-half of the valves.
63. For disconnectable economizers of the boilers, the places of installation of safety valves, their
adjustment procedure and values of their opening pressure are specified by the designer.
On direct-flow steam boilers where the first (with respect to water flow) part of heating surface is
disconnected from the other part of heating surface by shut-off valves during boiler start-up or stop,
the necessity of installation, the number and the dimensions of safety valves for the first part of
heating surface are specified by design documentation.
64. Diaphragm safety devices are installed on vessels and pipelines as follows:
a) if lever-operated weighted and spring safety valves cannot be used due to their delayed
action or for other reasons;
b) before safety valves in the case when safety valves cannot operate reliably due to harmful
impact of working medium (corrosion, erosion, polymerization, crystallization, sticking,
freezing) or possible leaks through closed valve of explosive and flammable, toxic,
environment-damaging substances. The device allowing to
shall be provided for on the equipment in this case;
c) in parallel with safety valves for increase of the output of pressure relief systems;
d) on the outlet side of safety valves for the purpose of prevention of harmful impact of working
media from waste discharge system and exclusion of impact of the fluctuations of back
pressure from this system on the reliability of the operation of safety valves.
65. The necessity and the place of installation of diaphragm safety devices, and their design are
specified by the project of the equipment. Safety diaphragms are installed only in the attaching lugs
intended for them.
Diaphragm safety devices are located in the places open and accessible for their examination,
installation and dismantlement. Connecting pipelines are protected from freezing of working
medium in them, and safety devices are installed on branch pipes or the pipelines directly
connected to the equipment.

30
CU 032/2013

When diaphragm safety device is installed is consecutive with safety valve (before the valve or after
it), the cavity between the membrane and safety valve is connected to alarm manometer by bypass
tube (for the purpose of control of diaphragm serviceability).
Installation of switching device before diaphragm safety devices in the presence of doubled number
of diaphragm devices with maintenance of protection of the equipment against excess pressure at
any position of the switching device is allowed.
66. For the purpose of control of the level of liquid in the equipment with media interface, the devices
measuring the level of liquid working medium are applied. Together with liquid level indicators,
acoustic, light and other alarm devices, and lockers by limit liquid levels are installed on the on the
equipment.
67. On a steam boiler, except for direct-flow boiler, and on flame-heated or combustible gas-heated
vessel where decrease of the level of the liquid below allowed value is possible, not less than 2
direct-acting liquid level indicators are installed.
It is allowed to install indirect liquid level indicators in addition as duplicating ones. The number and
the places of installation of liquid level indicators in steam boilers (including those with step
evaporation in the drums or with portable separator), except for direct-flow boilers, and in flame-
heated or combustible gas-heated vessels are specified by the project of the equipment.
68. Direct-acting liquid level indicator shall have independent connection to the equipment. Installation
of 2 direct-acting liquid level indicators on connecting pipe (column) of the diameter not less than
70 mm is allowed.
Installation of intermediate flanges and shut-off valves except for measuring elements of signaling
devices of limit liquid levels, on direct-acting liquid level indicators is not allowed. The above
requirement does not apply to the flanges of shut-off valves which are the part of liquid level
indicators.
Connection of other devices to direct-acting liquid level indicator and to its connecting pipes or
nozzles is not allowed, except for the gauge of signaling device of limit liquid levels if the operation
of liquid level indicator is not disturbed then.
69. The configuration of the pipes connecting liquid level indicators with the equipment shall exclude
the formation of water pockets in them and provide the possibility of pipe cleaning. Connecting
pipes shall be protected from thermal heating by products of combustion of fuel and from freezing.
70. Direct-acting liquid level indicators are placed and illuminated so that liquid level was visible from
the workplace of maintenance personnel. On the equipment with working pressure above 4 MPa,
direct-acting liquid level indicators are equipped with the casings for protection of the personnel in
case of destruction of transparent plates.
71. The width of the sighting port of liquid level indicator is specified by the project of the equipment.
72. Liquid level indicators are supplied with shut-off valves for the purpose of their disconnection from
the equipment and purging. The directions of opening and marked on shut-off valves (molded,
embossed or painted), and on the valve cock, the position of its port is additionally marked. Internal
diameter of the port of shut-off valves shall be not less than 8 mm. For the purpose of water
discharge during the purging of liquid level indicators, funnels with protective arrangement and by-
pass pipe for the purpose of provision of equipment emptying are provided for.
73. When the pressure in the equipment is above 4,5 MPa, liquid level indicators are supplied with
2 tandem sets of shut-off valves for the purpose of their disconnection from the equipment.
74. If the distance from the platform from which the monitoring of liquid level in the equipment is carried
out to direct-acting liquid level indicator is over 6 m, and also if liquid level is not visible from the
workplace of maintenance personnel, then 2 lowered remote liquid level indicators are installed.
Installation of 1 direct-acting liquid level indicator on the equipment is allowed in this case.
Lowered remote liquid level indicators are connected directly to the equipment by separate nozzles
independent of other liquid level indicators and have steadying devices.
75. On waste heat boilers and industrial power boilers, remote liquid level indicators are installed on the
control panel (panels) of those boilers.
76. Steam boilers with electric heating are equipped with the system of automatic switching-off of
power supplies in the case of liquid level decrease below maximum permissible level.

31
CU 032/2013

77. The boilers are equipped with automatic acoustic and light alarm devices of upper and lower limit
water levels. The similar alarm system shall operate by all the parameters by which automatic
devices and safety devices actuate to stop the boiler.
78. Steam boilers irrespective of the type and steam-generating capacity are equipped with automatic
regulators of feed water supply. Steam boilers with steam temperature at the output from main or
intermediate steam superheater over
temperature regulation.
79. On the boilers with steam superheater, the devices for measuring temperature of superheated
steam the on each steam line before main shut-off valves are provided for. On the boilers with
intermediate steam superheating, temperature measuring means are installed at the input and at
the output of the steam.
80. On the boilers with natural circulation and steam superheating with steam-generating capacity
over 20 t/h and direct-flow boilers with steam-generating capacity over 1 t/h, together with indicating
measuring devices, measuring devices with continuous registration of the temperature of
superheated steam are provided for.
81. On steam superheaters with several parallel sections, besides the means of measuring of steam
temperature installed on general steam lines of superheated steam, the means of periodic
measurements of steam temperature at the output of each section are installed, and on steam
boilers with steam temperature above at the outlet part of steam superheater coils in the
amount of 1 measuring device per each meter of gas duct width.
82. On steam boilers with steam-generating capacity over 400 t/h, measuring means with continuous
registration of steam temperature are installed on the output part of steam superheater coils.
On steam boilers with steam desuperheaters for regulation of the temperature of steam
superheating, the means of measurement of appropriate values are installed before steam
desuperheater and after it.
83. On water input to economizer and water output from economizer, and also on feed water pipelines
of steam boilers without economizers, the means of measurement of feed water temperature are
provided for.
84. On water-heating boilers, water temperature measuring means are installed at water input to the
boiler and at water output from the boiler.
85. On water-heating boilers with steam-generating capacity over 4,19 t/h, registering means of water
temperature measurement at the output from the boiler are installed.
86. For the purpose of controlling the temperature of metal and prevention of its increase above
allowed values during the start, stop and maneuver modes of the boiler, the means of
measurement of temperature of the walls of its elements are provided for. The necessity of
installation of temperature measuring means, their number and location are specified by the
developer of boiler project.
87. The vessels operating at the changing wall temperature are equipped with temperature measuring
means for the purpose of monitoring the rate and uniformity of warming up of vessel body over the
length and height, and with indicators of thermal movements. The necessity of equipping the
vessels with temperature measuring means and indicators of thermal movements, allowed rate of
warming up and cooling of the vessels are specified by the developer of vessel project and are
given in the equipment certificate or in operation manual (instruction) by the manufacturer.
88. The equipment and its separate cavities with different values of pressure are equipped with direct-
acting pressure measuring means.
89. Steam boilers with steam-generating capacity over 10 t/h and water-heating boilers with steam-
generating capacity over 21 GJ/h shall be equipped with registering pressure measuring device.
90. Pressure measuring means take are placed:
a) on boiler drum;
b) on a boiler with steam superheater after steam superheater and before main shut-off
valve;
c) on vessel nozzle or on the pipeline between the vessel and shut-off valves;
d) on direct-flow boiler after superheater and before main shut-off body.

32
CU 032/2013

91. On water-heating boilers, pressure measuring means are placed on water input to the boiler and on
water output from the boiler before shut-off valves.
92. Accuracy class of pressure measuring means shall be not less than:
a) 2,5 at working pressure not over 2,5 MPa;
b) 1,5 at working pressure from 2,5 to 14 MPa inclusive;
c) 1 at working pressure over 14 MPa.
93. When pressure measuring device is installed at the height over 5 m, duplicating pressure
measuring device is provided for.
94. Equipment design provides for the possibility of a safe purging, checking and switching-off of
pressure measuring device.
95. The type of the valves, their number and place of installation are specified by the developer of the
equipment project proceeding from safety and switching-off of the equipment and its elements
provided for by the project.
96. In the case of group supply of feed water into the boilers, pump head is chosen taking into account
the requirements of technical regulations of the Customs union "On the safety of excess pressure
equipment" (CU TR 032/2013), and also proceeding from the condition of maintenance of boiler
feeding with the largest working pressure or with the largest loss of a pressure in feed water
pipeline.
97. Water supply by feeding devices is determined by rated steam-generating capacity of boilers taking
into account water expense for continuous or periodic purging, steam cooling, provision of
operation of reducing cooling and cooling devices, and also taking into account the possibility of
loss of water or steam.
98. The type, characteristics, number and scheme of switching-on of feeding devices provide safe
operation of the boiler while in service, including emergency stops.
99. Design (projection) of the pipelines shall:
a) for the pipelines of nominal diameter over 150 mm with working medium temperature
and above, determine (in the project) required number of the indicators of movements for
the purpose of controlling thermal expansion of pipelines and monitoring of correctness of
operation of suspension and support system;
b) provide for the devices for condensate removal in the cases when condensate formation is
possible inside the pipes transporting steam-and-gaseous working media. These devices
shall be located in lower points of the pipelines;
c) take into account the possibility of damage from infringements of hydraulic mode, and from
erosion-corrosion deterioration;
d) provide for the measures and means for decrease of vibration and exclusion of the possibility
of emergency destruction and depressurization of pipelines which are exposed to vibrations
while in service;
e) provide for the devices which disconnect the branches of pipelines in the cases when those
pipelines contain working media of group 1;
f) minimize the danger of accidental release of working medium. The places of sampling of
working medium shall be accurately designated with the indication of the name of working
medium;
g) develop technical documentation for underground pipelines, containing the data necessary
for their safe maintenance, monitoring and repair (steel grade, diameter, thickness of pipes,
pipeline length, arrangement of supports, compensators, suspension brackets, valves, air
grooves and drainage devices, welded connections with indication of the distances between
them and from them to wells and consumer connections, arrangement of the indicators for
control of pipeline condition and working medium parameters).
100. Pressure chamber design shall provide the possibility of examination (including internal surface),
cleaning, washing, purging and repair of pressure chamber.
101. Design (projection) of pressures chamber takes into account the loads arising at installation and
under the impact of inertial forces.
33
CU 032/2013

102. The duration of people staying in pressure chamber is specified by the project and is stated in the
certificate. In case of long staying of people in pressure chamber, compartments with various
functional purposes are provided for.
103. Equipment project shall provide for sealed lead-ins or high-pressure glands for electric cables,
which provide mechanical strength, axial and radial tightness, gas tightness of sealed lead-in as a
whole and its current-carrying elements, and also electric strength of the insulation over all
pressure range in pressure chamber.
104. The design of pressure chamber shall provide for the possibility of opening of pressure chamber
from inside and outside. It is not allowed to use locks for closing the doors or covers inside
pressure chamber.
105. For visual or television supervision over the conditions in pressure chamber and for illumination of
internal space, equipment project provide the windows equipped with external cover protecting
window glass from mechanical damage.
Light transmission materials with safety factor not less than safety factor of pressure chamber case
and with light transmission factor not less than 85 percent are used for design (projection),
manufacture (fabrication) of pressures chamber windows.
106. Equipment project provides for the systems of air and gas supply for the following purposes:
a) formation of gas medium in pressure chamber;
b) provision of operation of stationary respiratory system;
c) maintenance and change of pressure in pressure chamber;
d) maintenance and change of gas medium composition in pressure chamber with respect to
oxygen and indifferent gases;
e) air locking.
107. Air and gas supply systems provide pressure increase in pressure chamber with the rate not less
than 0,2 MPa/min for pressure from 0,1 to 1,7 MPa inclusive (1 17 kgf/cm2), not less than 0,1
MPa/min(1 kgf/cm2 for pressure over 1,7 MPa (17 kgf/cm2), and maintenance of
pressure with the accuracy 0,025 MPa (0,25 kgf/cm2). Pressure decrease in pressure chamber is
carried out with the rate 0,003 0,9 MPa/h (0,03 9 kgf/cm2 h).
108. Gas control means of pressure chamber shall provide the accuracy of measurement of oxygen,
helium and carbon dioxide contents, and possible harmful substances.
109. Fire protection system and means shall provide detection of fire starting in pressure chamber or
ignition pre-conditions (smoke, uncontrolled temperature rise), emergency signaling, and
suppression of detected fire by all means available in pressure chamber.
110. Automatic control means shall provide safe conditions of people staying in pressure chamber.
111. Each compartment and sluice of pressure chamber is equipped with a manometer which is installed
outside on the fitting welded to pressure chamber case, or on the panel of control of pressure
chamber systems.
112. Power networks of pressure chamber shall have backup power sources providing uninterrupted
operation of the elements of air and gas supply systems, fire protection systems and means.
113. All commutation-and-protective and start-control devices of power electric equipment are installed
out of pressures chamber. Power cables in pressure chamber shall have nonflammable insulation.
Pressure chamber project shall provide for the presence of the system of protection against static
electricity, the possibility of grounding of internal demountable metal products, equipment and the
case of pressure chamber.
114. Equipment project determines the necessity of installation of illumination. Lighting fixtures installed
inside pressure chamber shall be tight and shall be intended for working pressure of the medium.
115. Equipment project provides for the possibility of using facilities of communication with the people
who are inside pressure chamber.
116. Pipelines, steam and water heaters installed in pressure chamber, and supply pipelines for
compressed air and gas mixes installed outside of pressure chamber, are projected from seamless
copper pipes or stainless steel pipes.

34
CU 032/2013

117. Nonflammable (fire-protection) materials which are guaranteed not to release harmful substances
in the gas medium of pressure chamber are applied for internal equipping of pressure chamber.

35
CU 032/2013

Annex No. 3
to Technical regulations of the Customs union
"On the safety of excess pressure equipment"
( 032/2013)
Annex 3

REQUIREMENTS FOR DISTINCTIVE COLORING AND


IDENTIFICATION INFORMATION
I. Cylinders
Gas name Coloring of The text of the Colour of Colour of the
cylinders inscription inscription strip
1 2 3 4 5
Nitrogen black nitrogen yellow brown
Ammonia yellow ammonia black -
Argon, crude black argon, crude white white
Argon, technical black argon, technical Dark blue Dark blue
Argon, pure grey argon, pure green green
Acetylene white acetylene red -
Butylene red butylene yellow black
Petroleum gas grey petroleum gas red -
Butane red butane white -
Hydrogen dark green hydrogen red -
Air black compressed air white -
Helium brown helium white -
Nitrous oxide grey nitrous oxide black -
Oxygen blue oxygen black -
Oxygen medical blue oxygen medical black -
Hydrogen sulphide white hydrogen sulphide red red
Sulphurous anhydride black sulphurous anhydride white yellow
Carbonic acid black carbonic acid yellow -
Phosgene protective - - red
Freon-11 aluminum freon-11 black dark blue
Freon-12 aluminum freon-12 black -
Freon-13 aluminum freon-13 black 2 red
Freon-22 aluminum freon-22 black 2 yellow
Chlorine protective - - green
Cyclopropane orange cyclopropane black -
Ethylene violet ethylene red -
All other combustible red gas name white -
gases
All other nonflammable black gas name yellow -
gases

NOTES:
1. The inscription is applied along the circumference of a cylinder over the length not less than 1/3 of the
circumference, and a strip is applied over whole circumference. The height of the letters on the cylinders of capacity
over 12 l shall be 60 mm, and the width of the strip shall be 25 mm. On the cylinders of capacity up to 12 l, the sizes
of letters and strips shall be specified depending on the size of lateral surface of the cylinders.
2. Painting in grey or yellow of low-capacity cylinders (up to 12) for respiratory devices and self-rescue devices with
compressed air is allowed.
II. The tankers for transportation liquefied hydrocarbon gases
External surface of the tankers intended for transportation of liquefied hydrocarbon gases is painted in
light grey colour. Distinctive strip of red colour of the width not less than 200 mm with black-color
inscription "Propane inflammable" on it is applied on both lateral sides of the vessel. Black-color
inscription "inflammable" is applied on the back bottom of the vessel.

36