Sunteți pe pagina 1din 5

ETABS 2016 16.2.

1 License #*13GKCULR7HUKDLF

Connection Design: C1-BP


Units: kip-in

Story: Story2

Design Code: AISC 360-10

Column Base Plate Connection

Summary of results
Design Check Type D/C Ratio Result Reference
1 Concrete bearing capacity 0.073 Passed
2 Minimum base plate thickness 1.849 Failed
3 Anchor rod strength 6.552 Failed Design Guide 1, Secion 3.2.1
4 Weld strength 0.894 Passed J2-2, J2-3
5 Concrete pullout strength 3.538 Failed
6 Concrete breakout strength 0.492 Passed
7 Side-face blowout strength 0.253 Passed

Material Properties
Column HE300A A572Gr50 Fy = 50 ksi Fu = 65 ksi
Base Plate A992Fy50 Fy = 50 ksi Fu = 65 ksi

Geometric Properties
Column HE300A tw = 0.33465 in d = 11.42 in tf = 0.55118 in bf = 11.81 in

Bolts, Plate & Weld


Anchor rod Diameter = 0.98425 in Head/Nut type = Square Material = ASTM F1554 Grade36
Base Plate Width = 20 in Height = 20 in Thickness = 0.98425 in

Pedestal
Dimensions Width = 23.94 in Height = 23.94 in

Design Calculations

Modelo 4 Anclajes (19-05-18).EDB Page 1 of 5 9/09/2018


ETABS 2016 16.2.1 License #*13GKCULR7HUKDLF

Design calculations of base plate for combined moment and compression

Design Provision = LRFD

Load Combination = CombU1

Pu = -25.57225 kips, Mu = 4795.8 kip-in

Base plate area

N = Max[Nmin , (d + 2x3 in), [d + 2(Leh + c)]]

N = Max[9.84, (11.42 + 2x3 in), [11.42 + 2(2.46 + 1.48)]] N = 20 in

B = Max[Bmin , (bf + 2x3 in), {bf + 2(Lev + c)}]

B = Max[9.84, (11.81 + 2x3 in), [11.81 + 2(2.46 + 1.48)]] B = 20 in

S1 = N-2Leh S1 = 20-2(2.46) S1 = 15.08 in

S2 = B-2Lev S2 = 20-2(2.46) S2 = 15.08 in

Base plate dimension(B inch x N inch) = 20 x 20

A1 = B*N A1 = 20*20 A1 = 400 in2


A2 = (B + 2a)(N + 2b) A2 = (20 + 2*1.97)(20 + 2*1.97) A2 = 572.98 in2

e and ecrit
Mu 4795.8
e= e= e = 187.54 in
Pu 25.57

' A2
fp (max) = ϕ0.85fc Min(2, √ )
A1

572.98
fp (max) = 0.65*0.85*4Min(2, √ ) fp (max) = 2.65 ksi
400
kips
qmax = fp (max)B qmax = 2.65*20 qmax = 52.9
in
N Pu 20 25.57
ecrit = - ecrit = - ecrit = 9.76 in
2 2qmax 2 2*52.9
e is greater than ecrit, design the base plate with large moment

Concrete bearing capacity


N 2Pu (e + f)
[f + ]2 ≥
2 qmax

20 2 2*25.57(187.54 + 7.54)
[7.54 + ] ≥
2 52.9
Above inequality equation is satisfied
N 20
f= -L f= -2.46 f = 7.54 in
2 eh 2
N N 2 Pu (e + f)
Y = (f + )-√[f + ]2 -
2 2 qmax

20 20 2*25.57(187.54 + 7.54)
Y = (7.54 + )-√[7.54 + ]2 - Y = 6.63 in
2 2 52.9

Modelo 4 Anclajes (19-05-18).EDB Page 2 of 5 9/09/2018


ETABS 2016 16.2.1 License #*13GKCULR7HUKDLF

Tu = qmax Y-Pu Tu = 52.9*6.63-25.57 Tu = 325.13 kips


Pu 25.57 kips
q= q= q = 3.86
Y 6.63 in
q 3.86
D/C Ratio = D/C Ratio = D/C Ratio = 0.07292
qmax 52.9
D/C Ratio is less than 1

Minimum base plate thickness

At bearing interface
N-0.95d 20-0.95(11.42)
m= m= m = 4.58 in
2 2
B-0.8bf 20-0.8(11.81)
n= n= n = 5.28 in
2 2
fp = fp

Y is greater than max(m, n) so

fp
tp1 (min) = 1.5max(m, n)√
Fy

2.65 tp1 (min) = 1.82 in


tp1 (min) = 1.5max(4.58,5.28)√
50
At tension interface
d tf 11.42 0.55118
x = f- + x = 7.54- + x = 2.11 in
2 2 2 2
Tu x
tp2 (min) = 2.11√
BFy

325.13*2.11
tp2 (min) = 2.11√ tp2 (min) = 1.75 in
20*50
tp (min) = max(tp1 (min), tp2 (min)) tp (min) = max(1.82,1.75) tp (min) = 1.82 in

tp (min) 1.82
D/C Ratio = D/C Ratio = D/C Ratio = 1.85
t 0.98425
Increase base plate thickness

Anchor rod strength, Reference(Design Guide 1, Secion 3.2.1)

Force per anchor rod

Tu 325 kips
Pr = n Pr = Pr = 162.56
4
( )
2 ( ) bolt
2

πdr 2 3.14*0.984252
Ar = Ar = Ar = 0.76047 in2
4 4
kips
Rn = 0.75Fu Ar Rn = 0.75*58*0.76047 Rn = 33.08
bolt
kips
ϕRn = ϕRn ϕRn = 0.75*33.08 ϕRn = 24.81
bolt
Pr 162.56
D/C Ratio = D/C Ratio = D/C Ratio = 6.55
ϕRn 24.81

Modelo 4 Anclajes (19-05-18).EDB Page 3 of 5 9/09/2018


ETABS 2016 16.2.1 License #*13GKCULR7HUKDLF

D/C Ratio is greater than 1, select another anchor rod

Weld strength, Reference(J2-2, J2-3)

beff = S2-tw beff = 15.08-0.33465 beff = 14.74 in


Pr 162.56 kips
Ruw = Ruw = Ruw = 11.03
beff 14.74 in
0.707D
ϕRn = ϕ1.5*0.6FEXX *1*
16
0.707*5.91 kips
ϕRn = 0.751.5*0.6*70*1* ϕRn = 12.33
16 in
Ruw 11.03
D/C Ratio = D/C Ratio = D/C Ratio = 0.89423
ϕRn 12.33
D/C Ratio is less than 1, fillet on each side of the web is ok

Concrete pullout strength


'
ϕNp = ϕψ4 Abrg 8fc
ϕNp = 0.7*1.4*1.47*8*4 ϕNp = 45.94 kips
Pr 162.56
D/C Ratio = D/C Ratio = D/C Ratio = 3.54
ϕNp 45.94
Concrete pullout strength is not sufficient

Concrete breakout strength

ca1 = Leh + b ca1 = 2.46 + 1.97 ca1 = 4.43 in

ca2 = Lev + a ca2 = 2.46 + 1.97 ca2 = 4.43 in

ANo = 9hef 2 ANo = 9*19.692 ANo = 3487.51 in2


AN = (Min(2Ca1 , 3hef ) + Min(S1 , 3hef ))*(Min(2Ca2 , 3hef ) + Min(S2 , 3hef ))

AN = (Min(2*4.43, 3*19.69) + Min(15.08, 3*19.69))*(Min(2*4.43, 3*19.69) + Min(15.08, 3*19.69))

AN = 572.98 in2
hef is greater than 11 in, soϕNcbg is
5 AN
'
ϕNcbg = ϕψ3 16√fc [hef ]3 ( )
ANo
5 572.98
ϕNcbg = 0.7*1.25*16*√4*[19.69]3 ( )
3487.51
ϕNcbg = 660.2 kips
Tu 325.13
DCR = DCR = DCR = 0.49247
ϕNcbg 660.2
D/C Ratio is less than 1, Design is OK

Side-face blowout strength

ca1 = min((Leh + b), (Lev + a)) ca1 = min((2.46 + 1.97), (2.46 + 1.97)) ca1 = 4.43 in

ca2 = max((Leh + b), (Lev + a)) ca2 = max((2.46 + 1.97), (2.46 + 1.97)) ca2 = 4.43 in

Modelo 4 Anclajes (19-05-18).EDB Page 4 of 5 9/09/2018


ETABS 2016 16.2.1 License #*13GKCULR7HUKDLF

hef > 2.5Ca1


'
Nsb = ϕ160ca1 λa √Abrg fc

Nsb = 0.75*160*4.43*1√1.47*4 Nsb = 1286.62 kips

Ca2 3Ca1
1 ca2 1 4.43
Nsb = (1 + )N Nsb = (1 + )1286.62 Nsbg = 643.31 kips
4 ca1 sb 4 4.43
Pr 162.56
D/C Ratio = D/C Ratio = D/C Ratio = 0.2527
Nsb 643.31
D/C Ratio is less than 1, side face blowout is not possible

Modelo 4 Anclajes (19-05-18).EDB Page 5 of 5 9/09/2018