Documente Academic
Documente Profesional
Documente Cultură
6"
6"
6"
6"
6"
6" 6" 6"
6"
CENTER LINE
4'-6" 13'-7 12" 13'-7" 4'-6"
OF TV.
TV. SOCKET
2" CONDUTE
PIPE FOR TV.
FLOORING
TV. CONSOLE
5'-9" 5'-9"
5'-521"
8'-021"
7'-6 12"
7'-6 12"
Light Point
9'-7 12"
9'-7 12"
8'
Light Point
@ 7'-0" ht.
@ 7'-0" ht.
4'-4"
Light Point
@ 7'-0" ht.
7'-6 12"
7'-6 12"
BOX SIZE BOX SIZE
Fcl/Wl/ & Fan switches
3'-8"
3'-8"
3'-8"
3'-8"
@3'-6" HT.
9'-10 12"
9'-10 12"
6"
1 geyser + 1 exhaust point. Two Way switche @3'-6" HT.
Switch board (3 switch + 6 amp. FLOOR LVL.
Fcl/Wl/ & Fan switches
Light Point
@ 7'-0" ht.
socket + USB Point @ 2'-0" ht. from f.f.l.
HDMI @ 2'-0" ht. from f.f.l.) & @3'-6" HT. Light Point
A BED SIDE POINT B
6"
6"
to be connected from back of tv @ 7'-0" ht.
9'-9"
3'-8 12"
8'-4"
@3'-6" HT.
5'-10 21" 5'-10 12" 9'-1 12" 9'-1 12"
8'-4"
5'-9"
6'-1 12"
Light Point
@ 7'-0" ht.
9'-121"
9'-1 12"
8'-4"
Light Point Light Point Two 6 amp switch & socket @ 1'-6''ht. Light Point
CLOSET
@ 7'-0" ht. @ 7'-0" ht. @ 7'-0" ht.
8'-4"
5'-9"
6'-1 12"
12' 12'
5'-9" 5'-9"
11'-10"
5'-10 12"
9'-1 12"
9'-1 12"
3'-3"
1'
5'-3"
6 amp switch &
19'-7 12"
3'-221"
3'-2 12"
@3'-6" ht. from f.f.l.including Fcl & Wl switches @3'-6" HT. Fcl & Wl switches @3'-6" HT.
1 geyser + 1 exhaust point. 6" 1'
7'-4"
Light Point
Light Point Point to be left ceiling
@ 7'-0" ht.
11'-721"
921"
motorised for curtain @3'-6" ht. from f.f.l.including Light Point
1 geyser + 1 exhaust point. @ 7'-0" ht.
8'-10" 8'-4" 5'-1" 3'-9"
Point to be left ceiling Fcl/Wl/ & Fan switches +
Two Way switche
motorised for curtain A.C. Point @3'-6" HT. DRESS
BEDROOM-2 @3'-6" HT. Fcl & Wl switches @3'-6" HT.
Light Point Point to be left ceiling Point to be left ceiling &16 amp POINT @ 9" HT. AUTOMATION 11'-6" X 13'-9"
6'-8"
6"
4'-9"
@ 7'-0" ht. A.C. Point @3'-6" HT. Fcl/Wl/ & Fan switches +
HDMI @ 2'-0" ht. from f.f.l.) & Fcl/Wl/ & Fan switches + AUTOMATION ELECTRICAL
Fcl/Wl/ & Fan switches &16 amp POINT @ 9" HT. A.C. Point @3'-6" HT.
to be connected from back of tv A.C. Point @3'-6" HT. POINT AS / VENDOR
@3'-6" HT. &16 amp POINT @ 9" HT. Fcl & Wl switches @3'-6" HT. 6"
16 amp. socket @ 0'-9" ht. from f.f.l. &16 amp POINT @ 9" HT.
EPBX + 6 amp. socket + 16 amp. socket
Wall light point @ 4'-0" ht. from f.f.l. @ 0'-9''ht. from f.f.l.
6'-4 12"
6" 6" 6"
5'-121"
5'-10 12"
3'-8 12"
3'-8 12"
11'-7 12"
12'-4 12"
8'-4"
3'-821"
12'-0 21" 6" 7'-3 12" 7'-321" 6" 6" Fcl/Wl/ & Fan switches + Fcl/Wl/ & Fan switches +
9'-5" 9'-5" 9'-5" 9'-5" 8'-4" 8'-8 12"
A.C. Point @3'-6" HT. A.C. Point @3'-6" HT.
4'-8"
5'
5'
6'-1021"
6'-1 12" 6'-1 12" @3'-6" HT. 16 amp.socket @ 0'-9''ht. from f.f.l.
6"
12'
5'
8'
1
2
Fcl/Wl/ & Fan switches Fcl/Wl/ & Fan switches Switch for TV. @ 1'-6''ht.
6"
Switch board (3 switch + 6 amp. @3'-6" ht. from f.f.l.including 2'-9 12"
1 geyser + 1 exhaust point. 6"
socket + USB Point @ 2'-0" ht. from f.f.l. 1 geyser + 1 exhaust point.
6"
16 amp. socket @ 0'-9" ht. from f.f.l. @3'-6" ht. from f.f.l.including @3'-6" ht. from f.f.l.including
7'-0 12"
Wall light point @ 4'-0" ht. from f.f.l. 1 geyser + 1 exhaust point.
3'-7 12"
3'-7 12"
6"
7'-11 12" 7'-2 12" 4'-11" 1'-8 12" 1' 1' 5'-1"
612"
9"
9"
BEDROOM-3 13'-5" 14'-2" 7'-10 21" 6'-1 12" 6" Fcl/Wl/ & Fan switches
16'-0" X 26'-0" @3'-6" HT.
6"
@3'-6" HT.
6"
2'-2"
11'-1 21"
4'-0 12"
1'-6"
DRAWING ROOM
36'-0" X 21'-0"
6"
6"
6"
9'-621"
10 12" Fcl/Wl switches Fcl/Wl/ & Fan switches Fcl/Wl/ & Fan switches
@3'-6" HT. @3'-6" ht. from f.f.l.including @3'-6" ht. from f.f.l.including
6"
10 12"
Fcl/Wl switches
6 amp POINT @ 9" HT. @3'-6" HT.
8'-4"
6"
Fcl/Wl/ switches
@3'-6" HT.
Drawing Name :
GROUND FLOOR WALL
ELECTRICAL PLAN
Drawing Code : Scale : FTS
GFC/SR/A801/R0 Project No : P430
Client Name :
MR.ANURAG CHAWLA
PLOT NO - FARM HOUSE
Date : Revision No : S
13/03/2019 R0 E W
N
Drawing Status :
DRAWN BY :
HEMENDRA/RAM