Sunteți pe pagina 1din 563

Grand Summary

Name of Works: Expansion of Osmani International Airport, Sylhet (1st Phase)

IFT No. , Package No. CAAB/OLA/WD-01/2018-19 Lot No. Single Lot

No General Summary Reference

1 Preliminary & General Items

2 Land Development Works

3 Building Works

4 Civil Works

5 Electro-Mechanical Works

6 Communication & Security Equipments

7 Fuel Hydrant Works

Subtotal of (1-7)

8 Provisional Sums

In figures
GRAND-TOTAL INCLUDING PROVISIONAL SUM(1-8)
In words

1 Preliminary and General Items 一般项


2 Land Development Works 土地开发
3.1 Foundation Works 房建基础(桩基)
3.2 Super-structure Works 土建结构
3.2.3 Steel Structure Works 钢结构
3.3 Finishing Works 饰面装修
3.4 Furniture 家具
3.5 Fire Fighting System 消防系统
3.6 Plumbing and Sanitary Works 给排水
3.7.1 Internal Electrification Works 内部电力系统(弱
电)
3.7.2 Electrical Substation works 电站(强电)
3.7.3 ADDRESSABLE FIRE DETECTION & ALARM SYSTEM 火警系统
3.7.4 SEWAGE TREATMENT PLANT 污水处理厂
4 Civil Works 跑道及停机坪
5.1 Airfield Ground Lighting ( AGL ) System 助航灯光
5.2 HVAC SYSTEM
高压交流电系统
5.3 MECHANICAL EQUIPMENTS
5.3.1 ELEVATOR & ESCALATOR 电梯及扶梯
5.3.2 PASSENGER BOARDING BRIDGE 登机桥
5.3.3 BAGGAGE HANDLING SYSTEM 行李系统
5.3.4 CUTE SYSTEM
通讯终端设备系统
5.3.5 GATE MANAGEMENT SYSTEM, FLIGHT CONTROL & AODB 门禁系统
5.3.6 MAST LIGHTING SYSTEM 桅灯系统
5.3.7 CABLE SUPPORTTING SYSTEM 电缆系统
5.3.8 LIGHTNING PROTECTION SYSTEM 避雷系统
5.3.9 AIRPORT SIGNAGE SYSTEM 机场标识系统
6 Communication & Security Equipments
通讯及安检设备
7 Construction of Fuel Hydrant Pipe line 燃油供应管线
Phase)

gle Lot

Amount

50,000,000.00
Expansion of Osmani International Airport

Item No.

1
1

1.1

1.2

1.3

1.4

N.B.: The Cost of all other items that are to be carried out under section: 7 and 8 of Tender document but no
items of Work.
Expansion of Osmani International Airport, Sylhet (1st

Description of Item

2
Preliminary and General Items

Provision for living accommodation (1200 sq.m) for the Employer, the Engineer and their staff in/cl
furnishings the accommodation, supply of house hold, equipment’s and utensils, maintenance of
accommodation, supply of furniture, fittings, fixtures, and consumable materials etc. all complete as per
detailed description of the relevant specification and direction of the Engineer in charge.

Providing of furniture and field office equipment and maintenance of field Office including furniture,
fixtures, Equipment and supply of consumables etc. all complete and as per instruction of the Engineer. And
provision for security and their maintenance etc. all complete as per detailed description of the relevant
specification and direction of the Engineer in charge.

Construction of Contractors site office (400 Sq.-m), Consultant site office (400 Sq.-m) and Field Laboratory
building (400 Sq.-m) including toilet, fittings, utilities, services and development of surrounding area,
providing of laboratory testing equipment’s, and provision of staffs for maintenance of laboratory building,
equipment and furniture with all supplies, consumables etc. all complete as per detailed description of the
relevant specification and direction of the Engineer in charge.

Provide vehicles (in good running condition for 24 hours) on rental basis for the Employer, Engineer and
their staffs having Jeep 4 Nos @ 33 months each, 4 door Pick- up 1 No. @ 33 months each, and Microbus
(Noah/Voxy or equivalent type with auto door opening system)4 Nos @ 33 Months, each shall
include fuel, servicing, maintenance, driver, drivers wages, taxes, duties, registration, insurance etc.all complete
as per detailed description of the relevant specification and direction of the Engineer in charge. as applicable.

a) Jeep
b) Microbus
c) Pick-up
Sub-Total (Preliminary and General Items)

B.: The Cost of all other items that are to be carried out under section: 7 and 8 of Tender document but not included as
ms of Work.
ational Airport, Sylhet (1st Phase)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

month 33.00

sum 1.00

sum 1.00

month 132.00
month 132.00
month 33.00

document but not included as a pay item in BOQ shall be deemed to be included with the other
Item No.

2.1

2.2

2.3

2.4

2.5

2.6

2.7

2.8

2.9

2.10
Description of Item

Land Development Works

Demolition of existing Asphalt Pavement of any thickness manually or mechanically, carrying the material
by track or any other means within Airport area including loading and unloading at both ends, disposal and
compaction as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Demolition of existing concrete Pavement of any thickness manually or mechanically, carrying the material
by track or any other means within Airport area including loading and unloading at both ends, disposal and
compactionas per design, drawing, specification of relavant chapter and accepted by the Engineer.

Demolition of existing interlocking block of any thickness manually or mechanically , carrying the material
by track or any other means within Airport area including loading and unloading at both ends, disposal and
compaction as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Demolition of existing brick wall of any thickness manually or mechanically, carrying the material by track or
any other means within Airport area including loading and unloading at both ends, disposal and compaction
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Earth work in excavation of any thickness in all kinds of soil for pavement or any other structure, carrying the
material by track or any other means within Airport area including loading and unloading at both ends,
disposal and compaction as per specification of relavant chapter and accepted by the Engineer.

Construction of Sand Compaction Pile of 200 mm dia. by tripod, hammer, winch machine, providing
temporary steel casing pipe of 200 mm dia of required length using coarse sand of F.M. not less than 2.5 with
proper compaction all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer.

Sand filling where required with suitable sand having minimum F.M. 1.5 with all lead and lift including
leveling, watering and compaction to achieve density not less than 98% in top 600 mm and 95% in rest of
the filling depth of maximum dry density as determined by the ASTM D-1557 by ramming each layer
up to finished level as per design, drawing, specification of relavant chapter and accepted by the
Engineer. Compacted thikness of each layer shall not be more than 150mm.

Lime treatment work for soil modification to achieve required strength to a specific level by constructing one or
more courses of a mixture of soil, lime, and water in accordance with the design, drawing, specification of relavant
chapter and accepted by the Engineer.

Seeding: This item shall consist of soil preparation, including fertile soil, seeding the areas in accordance
with the design, drawing, specification of relavant chapter and
accepted by the Engineer.
Sodding: This item shall consist of furnishing, hauling, including fertile soil and placing approved live sod on
prepared areas in accordance with the design, drawing,
specification of relavant chapter and accepted by the Engineer.
Sub-Total (Land Development Works)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

cum 5380.30

cum 3655.00

cum 51.10

cum 1608.20

cum 838984.00

Rm 150000.00

cum 576266.50

cum 31702.00

Sqm 342089.00

Sqm 160718.00
Item No.

3
3.1
3.1.1

3.1.1.1

3.1.1.2

3.1.1.3

3.1.2

3.1.2.1

3.1.2.2

3.1.2.3

3.1.3

3.1.3.1
3.2
3.2.1

3.2.1.1

3.2.1.2

3.2.1.3

3.2.1.4
3.2.1.4

3.2.1.5

3.2.2

3.2.2.1

3.2.2.2

3.2.2.3

3.2.2.4

3.2.2.5

3.2.2.6

3.2.2.7
3.2.2.8

3.2.3

3.2.3.1

3.2.3.2

3.2.3.3

3.2.3.4

3.2.3.5

3.2.3.6

3.2.3.7

3.2.3.8

3.2.3.9

3.3
3.3.1

3.3.2

3.3.3

3.3.4

3.3.5

3.3.6

3.3.7

3.3.8
3.3.9

3.3.10

3.3.11

3.3.12

3.3.13

3.3.14

3.3.15

3.3.16

3.3.17

3.3.18

3.3.19
3.3.20

3.3.21

3.3.22

3.3.23

3.3.24

3.3.25

3.3.26

3.3.27

3.3.28

3.3.29
3.3.30

3.3.31

3.3.32

3.3.33

3.4
3.4.1

3.4.2

3.4.3

3.4.4

3.4.5

3.4.6

3.4.7

3.4.8

3.4.9

3.4.10

3.4.11

3.4.12

3.4.13

3.4.14
3.4.15

3.4.16

3.5
3.5.1

3.5.1.1

a
b
c
d
e
f
g
h
i
j
k

3.5.1.2

a
b
c
d

3.5.1.3

a
b

3.5.1.4

3.5.1.5

a
b
c
3.5.1.6

3.5.1.7

a
b

3.5.1.8

3.5.1.9

3.5.2

3.5.2.1

c
3.5.2.2

3.6
3.6.1

3.6.1.1

3.6.1.2

3.6.1.3

3.6.2

3.6.3

3.6.4

3.6.5

3.6.6

3.6.7
3.6.8

3.6.9

3.6.10

3.6.11

3.6.12

3.6.13

3.6.14

3.6.15
3.6.16

3.6.17

3.6.18

3.6.19
3.6.20

3.6.21

3.6.22

3.6.23

3.6.24
3.6.25

3.6.26

3.6.27
3.6.28

3.6.29

3.7.1

3.7.1.1

a
b
c
d
e
f
g
h

3.7.1.2

3.7.1.3

3.7.1.4

a
b
c
d
e
f
3.7.1.5
3.7.1.6

3.7.1.7

3.7.1.8

a
b
c
d
e
f
g
h
i
j

3.7.1.9

3.7.1.9.1
a
b
c
3.7.1.9.2
a
b
c
3.7.1.9.3
a
b
c
3.7.1.10

3.7.1.11
3.7.1.12
3.7.1.13
3.7.1.14
3.7.1.15
a
b
c
3.7.1.16

3.7.1.17
3.7.1.18
3.7.1.19

3.7.1.20

3.7.1.21

3.7.1.22

d
e

3.7.2
3.7.2.1

3.7.2.1.1

3.7.2.1.2

3.7.2.1.3

3.7.2.1.4

3.7.2.1.5
3.7.2.1.6

3.7.2.2

3.7.2.2.1

3.7.2.2.2

3.7.2.2.3
3.7.2.2.4

3.7.2.2.5

3.7.2.2.6

3.7.2.3

3.7.2.3.1
3.7.2.3.2

3.7.2.3.3

3.7.2.3.4

3.7.2.3.5

3.7.2.5

3.7.2.6

3.7.2.6.1
3.7.2.6.2

3.7.2.6.3
3.7.2.6.4

3.7.2.6.5

3.7.2.7
3.7.2.7.1

3.7.2.7.2
3.7.2.7.3

3.7.2.7.4

3.7.2.8

3.7.2.8.1

3.7.2.8.2
3.7.2.8.3
3.7.2.8.4

3.7.2.8.5
3.7.2.8.6
3.7.2.8.7

a
b
c
d
e
f
3.7.2.9
a
b
c
d
e
f
g
j
i
j
k
l
m
n
3.7.2.10
a
b
c
d
e
f
g
j
3.7.2.11

3.7.2.11.1

3.7.2.11.2

3.7.2.11.3

3.7.2.11.4

3.7.2.11.5

3.7.2.11.6
3.7.2.11.7
3.7.2.11.8

3.7.3
3.7.3.1
3.7.3.2

3.7.3.3

3.7.3.4

3.7.3.5

3.7.3.6

3.7.3.7
3.7.3.8

3.7.3.9

3.7.3.10

3.7.3.11

3.7.3.12

3.7.3.13
3.7.4

3.7.4.1

3.7.4.2

3.7.4.3
3.7.4.4

3.7.4.5

3.7.4.6

3.7.4.7

3.7.4.8

3.7.4.9
3.7.4.10

3.7.4.11

3.7.4.12

3.7.4.13

3.7.4.14

3.7.4.15

3.7.4.16

3.7.4.17
3.7.4.18

3.7.4.19

3.7.5

3.7.5.1
3.7.5.2

3.7.5.2.1

3.7.5.2.2

3.7.5.2.3

3.7.5.3

3.7.5.4
3.7.5.5

3.7.5.6

3.7.5.7

3.7.5.8

3.7.5.9
3.7.5.10

3.7.5.11

3.7.6
3.7.6.1
Description of Item

Building Works
Foundation Works
Pile Works

Construction of cast-in-situ pile by Auger Boring/ Rotary Drilling up to the required depth and diameter
with reinforced cement concrete of Class 25, carrying the spoils / mud accumulated during boring by
truck or any other means within Airport area, disposal and compaction, everything complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer. (Rate is excluding
the cost of reinforcement and its fabrication).

Breaking head of cast in situ bored Service pile/precast pile up to required length by any means and carrying the
dismantled materials by truck or any other means within Airport area including loading and unloading at both
ends, disposal and compaction as per specification of relavant chapter and accepted by the Engineer.

Conducting static load test as per ASTM D1143 or equivalent standard for the cast-in- situ/pre-cast pile providing
required scaffolding, bracing, jacks, pressure test gauge, loading unloading, Kentledge and other plants
and equipment including staging, mobilization, demobilization, hire charge, gunny bags, sand and filling
sacs/gunny bags for loading, record readings and preparation of results in standard forms and other
incidental charges as per standard practice and procedures including submission of load test report, furnishing all
graph and chart etc. complete in all respect as per specification of relavant chapter and accepted by the Engineer.

a) For 200 tonne load on test pile


b) For 150 tonne load for on Service pile
Pile Cap, short column and grade beam

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
below cement concrete, reinforced concrete slab etc. all complete as per detailed description of the relevant
specification and direction of the Engineer in charge.

Construction of Lean Concrete in foundation or in floor, Composed of aggregates, Portland cement, water
and approved additives in conformity with the lines, grades, etc. including cost of formwork all complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Reinforced cement concrete (Class 32) works using steel shutter with minimum cement content relates to mix
design having minimum f'cr = 40 Mpa, and satisfying a specified compressive strength f’c = 32 Mpa including
cost of formwork etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication).

a) Individual & Combind footing, Pile Cap, raft/mat.


b) In short column, lift wall, retaining wall etc.
c) In grade beam
Reinforcement

Supplying, carrying and fabrication of Grade 60 ribbed or deformed bar complying BDS ISO 6935-2:2006,
produced and marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 414
MPa but fy not exceeding 450 MPa and whatever is the yield strength within allowable limit as per BNBC/
ACI 318, the ratio of ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum
elongation after fracture and minimum total elongation at maximum force is 16% and 8% respectively. All
complete as per detailed description of the relevant specification and direction of the Engineer in charge.
Super-structure Works
RCC Floor Slab, Column, Beam etc.

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
below cement concrete, reinforced concrete slab etc. all complete as per detailed description of the relevant
specification and direction of the Engineer in charge.

Construction of Lean Concrete in foundation or in floor, Composed of aggregates, Portland cement, water
and approved additives in conformity with the lines, grades, etc. including cost of formwork all complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Reinforced cement concrete (Class 32) works using steel shutter with minimum cement content relates to mix
design having minimum f'cr = 40 Mpa, and satisfying a specified compressive strength f’c = 32 Mpa including
cost of formwork etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication).

a) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at
ground floor
b) In Column, Column Capital, Lift wall, Walls etc. at ground floor
c) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 1st
floor
d) In Column, Column Capital, Lift wall, Walls etc. at 1st floor
e) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 2nd
floor
f) In Column, Column Capital, Lift wall, Walls etc. at 2nd floor
g) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 3rd
floor
h) In Column, Column Capital, Lift wall, Walls etc. at 3rd floor
i) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 4th
floor
j) In Column, Column Capital, Lift wall, Walls etc. at 4th floor
k) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 5th
floor
l) In Column, Column Capital, Lift wall, Walls etc. at 5th floor
m) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 6th
floor
n) In Column, Column Capital, Lift wall, Walls etc. at 6th floor
o) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 7th
floor
p) In Column, Column Capital, Lift wall, Walls etc. at 7th floor
q) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 8th
floor
r) In Column, Column Capital, Lift wall, Walls etc. at 8th floor
s) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 9th
floor
t) In Column, Column Capital, Lift wall, Walls etc. at 9th floor

Cast-in-place fair-faced concrete works with f'cr=30 Mpa and f'c=25 Mpa at 28 days on standard cylinders by
using 75% of OPC and 25% of white cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C
150 Type – I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.5, 20 mm down and well graded crushed
stone chips conforming to ASTM C-33 including cost of formwork etc. all complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer. (Rate is excluding the cost of reinforcement
and its fabrication).
For column, wall, beam, slab, drop wall, cornice etc. up to ground floor

Supplying, carrying and fabrication of Grade 60 ribbed or deformed bar complying BDS ISO 6935-2:2006,
produced and marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 414
MPa but fy not exceeding 450 MPa and whatever is the yield strength within allowable limit as per BNBC/
ACI 318, the ratio of ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum
elongation after fracture and minimum total elongation at maximum force is 16% and 8% respectively. All
complete as per detailed description of the relevant specification and direction of the Engineer in charge.

Brick wall, plaster works, patent stone, water proofing etc.

Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) in exterior walls including filling the
interstices with mortar, raking out joints, cleaning and socking the bricks at least for 24 hours before use and
washing of sand, necessary scaffolding, curing at least for 7 days etc. all complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

a) In ground floor
b) In 1st floor
c) In 2nd floor

Providing 125 mm thick brick work in superstructure (partition walls) with cement sand (F.M. 1.2) mortar
(1:4) with 10 hole machine made ceramic bricks of approved size having uniform colour, carefully laid in
cement mortar of uniform width & depth of joints, true to vertical and horizontal lines including racking out
joints, filling the interstices with same mortar, making bond with connected walls, cleaning, soaking brick at
least 24 hours and washing of sand, curing 7 days etc. all complete as per design, drawing, specification
of relavant chapter and accepted by the Engineer.

a) In ground floor
b) In 1st floor
c) In 2nd floor
Water-proofing membrane (Foreign made) on made up surface below the floor or below the horizontal surfaces
with temporary protective cover using polysterene/38 mm thick sand-cement mortar in 4:1 /or by equally
effective alternative all complete as per detailed description of the relevant specification and direction of the
Engineer.
Water-proofing membrane (Foreign made) on vertical or inclined wall /on plastered and
primed back-wall and concrete cast against membrane all complete as per detailed description of the
relevant specification and direction of the Engineer.

Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to plinth wall (1:4)
with cement up to 150 mm below ground level with neat cement finishing including washing of sand,
finishing the edges and corners and curing at least for 7 days, cost of water, electricity and other charges etc. all
complete as per detailed description of the relevant specification and direction of the Engineer.

Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to ceiling
R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and
finishing the corners and edges including washing of sand cleaning the surface, scaffolding and curing at least
for 7 days, cost of water, electricity and other charges etc. all complete as per detailed description of the
relevant specification and direction of the Engineer.
(Cement: CEM-II/A-M)

38 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality coarse sand minimum F.M. 2.2
and 12 mm down well graded stone chips, laying the concrete in alternate panels, compacting and finishing the
top with neat cement and curing at least for 7 days in all floors including cost of water, electricity and other
charges etc. all complete as per detailed description of the relevant specification and direction of the
Engineer.
Water proofing work on roof top surface with 2 layer 2.5 mm STP felt, 50 mm stylo foam, 75 mm thick
screed concrete with 8 mm dia MS rod, joint filling with sutable compound etc. all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Steel Structure Works

Supply, fabrication and installation of foreign made hot-rolled sections (W, H, I-shape, Channel, angle etc.) for
columns, beams, rafters, bracings etc. conforming to BS EN 1993, BS EN 10025 or BS EN10210 Grade
S345 steel or ASTM 242/242M Grade 50 with minimum yield strength of 345N/mm2 (50 ksi), and Structural
hollow sections shall be of hot rolled sections complying with BS EN 10210 Grade 50 with minimum yield
strength of 345N/mm2 (50 ksi).including the cost of testing of plates, application of red/grey-oxide primer
etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply and installation of galvanized decking panel according to ASTM A653, with minimum yield
strength of 345 MPa, including all necessry accessories (sheeting screws with washers, sealants etc.), testing of
materials etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply and installation of foreign made GI purlin & girt of any size conforming to "ASTM A653" grade
45, with a minimum yield strength of 310 MPa, including the cost of testing of materials, all complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply and fixing of connection bolts of variable diameter with nut and washer according to "ASTM
A325 Type 1 or equivalent” with Fu =720 Mpa, including the cost of testing of bolts, all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing foreign made Colour Bonded Zinc Alum sheet as per specification, RC
Roofing with necessary Insulation, Flashing and Capping, fitted and fixed with all necessary including 'J'
hook purlin with screws, limpet washers and putty etc. all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supply, Fiiting fixing of Rigid Insulation (Polyurethane Foam) as per as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
Providing Intumescent Fireproofing Paint coat applying to structural steel truss member etc. all complete as per
design, drawing, specification of relavant chapter and accepted
by the Engineer.

S.F & F (Foreign made) Heat Reflected foil made with duble providers resistance to heat transfer and top &
bottom cover by pure Aluminium foil facing Airspace in/c fitting, fixing the same by 20 mesh 24 BWG wire
mesh etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Suppply, fitting & fixing of Oriented Strand Board (2ply) Foreign Made: Work Should be done as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.

Finishing Works
Engineered Granite stone flooring (Forign made) (Minimum 25 mm thick) of any size and approved quality,
texture (Mirror polished top surface) over designed thickness of cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the marble stone to desired size, grinding and
finishing the edges, setting in position in proper level filling the gaps with white cement and colouring
pigments including supplying all necessary equipments/materials and finishing the top by pumic stone and
necessary auxiliary materials and water, electricity and other charges complete in all respect as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
(Cement: CEM-II/A-M)

Engineered Granite stone flooring (Forign made) (Minimum 25 mm thick) of any size and approved quality,
texture (Mat polished top surface) over designed thickness of cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the marble stone to desired size, grinding and
finishing the edges, setting in position in proper level filling the gaps with white cement and colouring
pigments including supplying all necessary equipments/materials and finishing the top by pumic stone and
necessary auxiliary materials and water, electricity and other charges complete in all respect as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
(Cement: CEM-II/A-M)

Supply fitting fixing of Vinyl tiles (Forign made) of any size and approved quality in floor irrespective of
color & /or design, with quality acrylic dispersion glue, cement sand (F.M 1.2) mortar (1:4) base and raking out
the joints with cement including cutting and laying the tiles in proper way and finishing with care etc. all
complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply fitting fixing of Porcelain tiles (Forign made) of any size and approved quality in floor with irrespective
of color & /or design, with cement sand (F.M 1.2) mortar (1:4) base and raking out the joints with cement
including cutting and laying the tiles in proper way and finishing with care etc. all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supply fitting fixing of Ceramic wall tiles (Forign made) of any size and approved quality in floor with
irrespective of color & /or design, with cement sand (F.M 1.2) mortar (1:4) base and raking out the joints
with cement including cutting and laying the tiles in proper way and finishing with care etc. all complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of high quality Rubber Studded floor tiles (Forign made) of any size and approved
quality in floor, irrespective of color & /or design, with adhesives in full thickness of tiles, filler/tiles grout in/c
cutting, shaping, placing in proper level etc. all complete as per design, drawing, specification of relavant chapter
and accepted by the Engineer.

Construction of hardenered floor with stone chips, coarse sand, metal chips, cement etc. as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of 9 mm thick perforated gypsum board false ceiling, framing by
aluminium T-bar of natural anodized finish suspended in 600 mm x 600 mm grid from ceiling by 12 SWG double
ply wire, fixed to the ceiling by rowel plug, screws, hooks, nails etc., maintaining straight lines and desired
finished level at bottom face including vertical wooden strut as required, making holes in slabs or beams by
electric drill machine and mending good the damages, if any during execution of the work all complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.
Supplying, fitting and fixing of aluminium false ceiling (Hunter Douglas or equivalent) of any size, shape, color
and design suspended from the ceiling with necessary framing arrangement etc. all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of decorative false ceiling and walling for VIP hall, corridor and toilet area as per
design, drawing, specification of relavant chapter and accepted by
the Engineer.

Epoxy enamel paint of approved quality and colour delivered from authorized local agent of the
manufacturer in a sealed container; surface preparation including cleaning, drying, making free from dirt etc.
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Premium synthetic enamel paint of approved best quality and colour delivered from authorized local
agent of the manufacturer(Berger robbialac supergloss synthetic enamel/Elite lucky seven/ Asian apcolipe
premium paint or equivalent brand) in a sealed container, having high water resistance, high bondibility,
flexiblity property; using specified brand thinner applying to metallic or wooden surface by brass/roller/spray
in two coats over single coat anti-corrosive coating including cleaning, drying, making free from dirt, grease,
wax, removing all chalked and scaled materials, all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Providing weather coating of approved quality and colour delivered from authorized local agent of the
manufacturer in a sealed container; surface preparation including cleaning, drying, making free from dirt
etc. as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Providing acrylic emulsion paint of approved quality and colour delivered from authorized local
agent of the manufacturer in a sealed container; surface preparation including cleaning, drying, making
free from dirt etc. as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of Foreign made heavy duty glass partition made of 10 mm low-E tempered glass +
12 mm air space + 5 mm clear tempered glass + 1.14 PVB + 5 mm clear tempered glass, fixed with heavy
duty aluminum section and all necessary accessories etc. all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing foreign made 10 mm thick clear tempered glass partition with heavy duty
stainless steel frame including all necessary arrangement and accessories as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Supplying, fitting and fixing 10 mm thick clear tempered glass partition with heavy duty aluminum frame
including all necessary arrangement and accessories as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing for aluminium curtain wall 200X150X6X9mm thik. I-Beam For Vertical
Frame. Supplying, Fabricating, Fitting and Fixing of 6mm+1.52PVB+5mm+12A+6mm
Double Low-E Teampared Laminated Insulated Glass. Powder Coated aluminum alloy profile, Materials
6063-T5. 2.5mm AP, adopted foreign brand for Capping the I- Beam Section. Later Embedding,
Galvanized Steel. Sealant: Weather Proof Silicon Sealant- Type S, Grade NS, Class 50 Use NT, A, G, M,
O. Minimum Joint Movement Capability ±50%.Structural Silicone Sealant- Type M, Use G and O. Elongation
300% all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of foreign made heavy duty 12 mm thick clear tempered glass Automatic
sliding doors with sensor system as per design, drawing, specification
of relavant chapter and accepted by the Engineer.
Supplying, fitting and fixing foreign made 10 mm thick clear tempered single/double leaf glass door including all
accessories 2 set maintenance auto closed special quality 4 nos clamping device, 1 set locking device, top
hinge and handle etc. All complete as per design, drawing, specification of relavant chapter and accepted by
the Engineer.
Supplying, fitting and fixing foreign made double/single leaf Complete Door made of metal shutter &
metal frame including door lock and all accessories finished with Electro
powder coating as per approved design and accepted by the Engineer.

Supplying, fabrication and Installation of foreign made (Minimum 5 mm thick) Aluminium


composite panel (Alucobond/Alcopanel/Alpolic) with multiple color combination approved by the
Engineer as per US Architectural Aluminium Manufacturer's Association (AAMA) in column, beam and
wall surface providing heavy duty aluminum section including supply of necessary hardwares,
consumables, scaffolding etc fitted with necessary accessories like rivet, screw, rowel bolt etc. all complete
in all respect as per as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying fitting and fixing of aluminium fixed louver as per the U.S. Architectural Aluminium
Manufacturer‟s Association (AAMA) standard specification and BDS 1879:2014 having 1.2mm thick
wall frame (size 76.20 mm, 38.10 mm, 0.707 kg/m), 5 mm thick louver section (size 55.02 mm, 37.39 mm,
0.22 kg/m) and 2.50 mm thick louver outer section (size 39.67 mm, 15.06 mm, 0.265 kg/m) and inner
inclined aluminium louver section fixed with above mentioned frame and all aluminium members (total weight
7.992 kg) will be anodized to aluminium bronze/silver/ss/black colour with a coat not less than 15 micrones in
thickness or powder coated to any colour with a coat not less than 25 micrones in thickness and density of 4 mg
per square cm etc including all accessories, neoprene, sealant, nuts and bolts etc. complete in all respect as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
Powder coated to any colour.

Making of ACCESS Floor made of Anti static UPVC which will be fixed over SS Frame fitted and fixed
in floor.The raise of floor will be 200mm. All fitting and fixing as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying, fitting and fixing Aluminium door frames, windows, partitions and curtain wall including
distortion free glass (6 mm thick) of designed thickness of approved quality and shade including cost of
fitting fixing all necessary accessories etc. complete in all respect as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying, fitting and fixing 10 mm thick tempered glass railing with 62 mm dia 3 mm thick SS pipe for hand
rail, 62 mm x 50 mm x 3 mm vertical box fitted with concrete slab by 85 mm x 85 mm x 8 mm SS plate @ 600
mm c/c including all fittings, fixtures etc. all complete in all respect as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Providing decorative metal nosing to the nose of tread of stair including fitting and fixing all complete
as per design, drawing, specification of relavant chapter and accepted
by the Engineer.

Supplying, fitting and fixing of rolling shutter of any design and shape made of 24 SWG
G.P. sheet unit minimum 69 mm width having 10 mm and 12 mm dia circular folding at ends, rolled in machine,
locked together properly to form rolling shutter, top of the shutter to be fitted with circular spring box
made of 22 BWG sheet, containing best quality spring made etc. complete in all respect as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Construction of column guard with reinforced cement concrete and heavy duty MS angle, plate etc. all complete
as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying, fitting & fixing of Protector made of 62mm dia SS Pipe fittinng and fixing as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing 12 mm thick burma teak (BT) veneered board in walling with best quality and
well seasoned garjan wood frame of section 75 mm x 38 mm at 600 x 600 mm in grid, fitted and fixed to wall by
plugs, nails, screws etc. including treatment of inner surface with termite and damp proofing agent maintaining
leveled and finished exposed faces including. making holes in wall and mending good the damages, if any
during execution of the work, also including cost and carriage of all materials, electricity, accessories, labour for
installation, scaffolding, screws, nails etc. including french polishing by 3 coats over a coat of priming
etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply Fitting fixing of 18 mm thick foreign made SDF board partation wall and door provided with best quality
items towel, soket, bolt, screws, round lock etc.approved by as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying fitting and fixing fixed skylight with 50 mm thick double toughend / acrylic glass, Argon gas filled in
gap and laminated the inner glass panes for added safty, fitted in Aluminium frame and fixing in roof truss
with Neoprene gaskit, as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Furniture
Supply and placing of Foreign made 3 seater lounge chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supply and placing of Foreign made 2 seater lounge chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supplying and placing of foreign made international standard Tension queu Belt including post as per
design, drawing, specification of relavant chapter and accepted by
the Engineer.
Supplying and placing of foreign made international standard Immigration counter set (2 person per counter) as
per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying and placing of foreign made international standard custom and security desks as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

Supplying and placing of foreign made international standard Baggage Troley as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting, fixing and placing of foreign made best quality complete set of furniture for VIP
Lounges as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

Supplying and placing of Full Sectariate table as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supplying and placing of Half Sectariate table as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supplying and placing of staff table as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying and placing of Full Sectariate Revolving Chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supplying and placing of Half Sectariate Revolving Chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supplying and placing of Staff Chair as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
Supplying and placing of Visitor's Chair as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
Supplying and placing of Book Shelf as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying and placing of File Cabinet as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Fire Fighting System


Fire Hydrant and Sprinkler

Supply, delivery, installation, testing and commissioning of all MS pipes (ASTM 53 SCH-40 wet steel or
BS1387 Class B) of various size for Sprinkler system. The works shall include all fittings, joints, tap off,
flexible joints, necessary support, fixing, brackets, hanger, vibration isolators, base plates, civil work etc. as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

DN 25mm pipe
DN 32mm pipe
DN 40mm pipe
DN 50mm pipe
DN 65mm pipe
DN 80mm pipe
DN 100 mm pipe
DN 150 mm pipe
DN 200 mm pipe
DN 250 mm pipe
DN 300 mm pipe
Supply, delivery, installation, testing and commissioning sprinkler heads complete with dropper pipes, heat shield,
sprinkler guards, where required etc. as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Upright 8.0 ( Standard )
Upright 5.6 ( Standard )
Upright 5.6 ( Quick Response )
Pendent 5.6 ( Standard )

Supply, delivery, installation, testing and commissioning sprinkler zone control valves (motorized butterfly
valve), each sprinkler control valve shall consist of stop valves, alarm valves, drain and test valves,
automatic air release valve, non-return valve, leather belt and lock, isolation valves c/w fire rated cable, MS
conduit etc to respective fire alarm panel etc. as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

DN 150mm
DN 100mm

Supply, delivery, installation, testing and commissioning sprinkler Alarm Check Valves assembly, motorized
butterfly valve, check valve, pressure gauges, alarm motor and gong c/w pipe, valve connection to drain, leather
belt and lock, fire rated cable, GI conduit etc to respective fire alarm panel etc as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

DN 200mm

Supply, install and commission fire stand pipe and hose system including DN 65 hose connection valve with
DN 40 adapter, DN 65 Pressure Reducing Valve, complete in all respects as per design, drawing, specification
of relavant chapter and accepted by the Engineer.

Hose Station Connection


DN 40 mm Drain Valves c/w end cap
DN 25mm automatic air release valve
Supply, delivery, installation, testing and commissioning, from fire department connection point to fire
stand pipe and hose system header inclusive of check valve, fittings, connection and fixing as specified
and location shown in drawings. The work shall include all necessary supports, brackets, fittings, elbows,
bends, tees, junctions, etc; as per design, drawing, specification of relavant chapter and accepted by the Engineer.

4-way Fire department connection complete with check valve, metal cabinet, ball drip
drain
DN 150mm fire department connection pipe c/w fire rating box if
necessary

Supply, delivery, installation, testing and commissioning of flow switches c/w fire rated cable, GI conduit etc to
respective fire alarm panel, complete with all necessary accessories as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

DN 200 mm
DN 150 mm

Supply, delivery, installation, testing and commissioning, of Pillar Hydrant including hose box at outer
premises. The work shall include all necessary supports, brackets, fittings, elbows, bends, tees, junctions, etc;
and providing all necessary accessories as per design, drawing, specification of relavant chapter and accepted by
the Engineer.

DN 65mm, 2-Way
Supply, deliver, prepare and application of paint for entired installed fire hydrant & sprinkler system
including subsystem and accessories as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
For Fire Pump Room

Supply, delivery, installation, testing and commissioning of Horizontal Split Case Centrifugal Fire Pump
Electric and Engine driven & Jockey Pump complete with motors, engine, foot valves, isolation vale, strainer,
flexible connection, air pressure vessel, pressure gauge sensors, pressure switches, vortex plate, electrical
cabling, control panel and all necessary accessories as per design, drawing, specification of relavant chapter
and accepted by the Engineer.

Electrical Motor Driven Main Fire Pump


Pump Type : Horizontal Split Case Centrifugal
Rated Flow: 1250 US GPM
Head : 130 M
RPM: 2900
Certification of Pump : UL Listed, FM Approved
Certification of Motor : UL Listed, FM Approved
Certification of Control Panel : UL Listed, FM Approved
Diesel Engine Driven Main Fire Pump
Pump Type : Horizontal Split Case Centrifugal
Rated Flow: 1250 US GPM
Head : 130 M
RPM: 2900
Certification of Pump : UL Listed, FM Approved
Certification of Engine : UL Listed, FM Approved
Certification of Control Panel : UL Listed, FM Approved
Electrical Motor Driven Jockey Pump
Pump Type : Vertical Multistage
Rated Flow: 50 US GPM
Head : 140 M
RPM: 2900
Certification of Control Panel : UL Listed, FM Approved

The system accessories and manufacturer's parts of the system or system components (including hardware
and software) which are not listed above, but required to form a complete functional system which meet the
design and operational intent complying with codes and standards. The contractor shall propose and itemize here
with unit cost or per lot.

Plumbing and Sanitary Works


Commode
Supplying, fitting and fixing foreign made VIP quality Smart Commode with automatic heating, drying, eleaning,
sensor-flush system including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying, fitting and fixing foreign made best & approved quality with automatic sensor
flush system including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain closed coupled
Commode ‘P’ or ‘S’ type with low down/flush tank and flush valve including all internal fittings as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
Super quality: TOTO, American Standard, Duravit, Japanese or European origin or Equivalent of
approximate size (695mm x 412mmx 880mm) with flush tank.

Free Standing Built -In Sensor Urinal:


Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain Free Standing
Built -In Sensor Urinal including all internal fittings as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(445mm x 355mm x 330mm)
Wall Hung Flash Valve Urinal:
Supplying, fitting and fixing foreign made approved quality white glazed porcelain Wall Hung Flash Valve
Urinal including all internal fittings as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(610mm x 375mm x 85mm)
Hand Wash Basin with Full or Half Pedastal:
Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain Hand Wash
Basin with Full or Half Pedastal including all internal fittings as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(525mm x 415mm x 860mm)
Under Counter Square Basin:
Supplying, fitting and fixing foreign made best & approved quality white glazed
porcelain Under Counter Square Basin including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(530mmx430mmx220mm)
Stainless Steel Sink with Sink Tray:
Supplying, fitting and fixing foreign made best & approved quality Stainless Steel Sink with Sink Tray
including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Stainless Steel Sink with Sink Tray (Size 450mm x 1050mm)
100% SS304 coating.
Soap Dispenser :
Supplying, fitting and fixing foreign made best & approved quality Soap Dispenser including all internal
fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
JVD, Teka or Equivalant of approximate size (200-220mm x 100-120mm)
Toilet Paper Holder with Cover :
Supplying, fitting and fixing foreign made best & approved quality Toilet Paper Holder
with Cover including all internal fittings as per design, drawing, specification of relavant chapter and accepted by
the Engineer.
Toto, Grohe, American Standard or Equivalent
Glass Mirror:
Supplying, fitting and fixing foreign made best & approved quality Glass Mirror including all internal
fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Rolled Hand Tissue dispenser and Automatic Hand Drier
a) Supplying, fitting and fixing foreign made best & approved quality stainless steel Rolled Hand Tissue
dispenser as per design, drawing, specification of relavant chapter
and accepted by the Engineer.

b) Supplying, fitting and fixing foreign made best & approved quality Automatic Hand
Drier as per design, drawing, specification of relavant chapter and accepted by the Engineer.
Basin Mixture:
Supplying, fitting and fixing foreign made best & approved quality Basin Mixture
including all internal fittings as per design, drawing, specification of relavant chapter and accepted by the
Engineer.
Toto, Grohe, Hans Grohe or Equivalnet
Push shower and Bib Cock :
Supplying, fitting and fixing foreign made best & approved quality Push shower and Bib
Cock including all internal fittings as per design, drawing, specification of relavant chapter and accepted by
the Engineer.
a). 12 mm C.P Push Shower
b). 12 mm C.P Bib cock
Angle Stop Cock:

Supplying, fitting and fixing foreign made best & approved quality Angle Stop Cock
including all internal fittings as per design, drawing, specification of relavant chapter and accepted by the
Engineer.

a). 12 mm dia stop cock (Special quality)


Grating:
Supplying, fitting and fixing best quality grating in traps or in drains and where necessary including making holes
in walls and floors and mending good the damages and supply and carriage of all materials, labour, tools,
incidentals, etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer.
a) 125 mm dia Brass/ 304 SS Coated gratings
b) 100 mm x 100 mm size SS Quoted grating with hinged cover 100% Brass/ SS 304
coating
c) 50 mm dia SS Quoted gratings
u-PVC Floor Traps:
Supplying, fitting and fixing the following type floor traps (Siphon or P -trap) for floor drain including making
holes in walls and floors and mending good the damages including supply and carriage of all materials,
labour, tools, incidentals, etc. all complete as per design, drawing, specification of relavant chapter and accepted
by the Engineer.
a). uPVC floor trap 110 mm dia.
b). uPVC floor trap 50 mm dia.
uPVC Pipe & Fitting:

Supplying, fitting and fixing different diameter best quality heavy type uPVC pipes (RFL/National/Hatim
or equivalent) and will be completed all uPVC fittings like tees, Y, cross-tee, reducer-Y, elbows, bends, Offset,
sockets, reducers, test opner or door socket, clean out cap and vent cowl with solvent cement clamping to
wall or hanging under ceiling or concealed properly at an interval of not more than 1200mm as in
drawing, groove cutting in brick work, R.C.C floor, making holes and mending good the damages including
supply and carriage of all materials, labour, tools, incidentals etc. complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

uPVC Pipes :
a). 32 mm dia, 1.6 mm thick
b). 40 mm dia, 1.9 mm thick
c). 50 mm dia, 2.4 mm thick
d).100 mm dia, 4.5 mm thick
e). 110 mm dia, 4.2 mm thick
f). 160 mm dia, 6.2 mm thick
g). 200 mm dia, 7.7 mm thick
h). 250 mm dia, 9.6 mm thick
i). 315 mm dia, 12.1 mm thick
CPVC Pipe & Fitting:

Supplying, fitting and fixing different diameter best quality CPVC Pipe of 10.5 kg/cm2 tested pressure for water
supply as per BSTI approved manufacturer standards or ASTM/BS/ISO/IS standards and fixed in position
with all CPVCfitting such as sockets, bends, elbows, tees, reducing tees, reducing sockets, reducing elbows,
union, plug with all other related accessories and cutting groove / trenches where necessary and filling the same
with earth duly rammed and fixing in walls with holden bats and making holes in floor and walls and supply
and carriage of all materials, labour, tools, incidentals etc. complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

a). 12 mm dia, wall thickness 2.8 mm to 3.3 mm


b). 20 mm dia, wall thickness 2.9 mm to 3.4 mm
c). 25 mm dia, wall thickness 3.4 mm to 4.0 mm
d). 32 mm dia, wall thickness 3.6 mm to 4.2 mm
e). 40 mm dia, wall thickness 3.7 mm to 4.3 mm
f). 50 mm dia, wall thickness 3.9 mm to 4.5 mm
g). 65 mm dia, wall thickness 5.8 mm
h). 75 mm dia,wall thickness 6.8 mm
Ball Valve:

Supplying, fitting and fixing best quality CPVC Body gate valve of 12 kg/cm2 tested pressure, including
supply and carriage of all materials, labor, tools, incidentals etc. complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

a). 20 mm dia
b). 25 mm dia
c). 32 mm dia
d). 40 mm dia
e). 50 mm dia
f). 65 mm dia
g). 75 mm dia
Pressure Reducing Valve:
Supplying, fitting and fixing pilot operated gate and diaphragm type pressure reducing valves Germany/ Italy/ or
equivalent complete with inlet and outlet service on riser lines to reduce pressure from 30 psi to 7 psi (2.11-0.49
kg/cm2) including making water tight joints of the valves and fitting by using proper sealing compound, supply of
all labour, tools, incidentals, etc. all complete as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

a). 25 mm dia
b). 32 mm dia
c). 40 mm dia
d). 50 mm dia
e). 65 mm dia
Foot Valve with Strainer
Supplying, fitting and fixing best quality float valve with strainer shall be made of cast
iron flange end type complete with companion flanges, gasket, nuts, bolts etc. as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
a). 50 mm dia.
Non-Return Valve / Check Valve :

Supplying, fitting and fixing best quality gun metal non-return valve including supply and carriage of all
materials, labor, tools, incidentals etc. complete as per design, drawing, specification of relavant chapter and
accepted by the Engineer. Product shall be standard quality or approved equivalent. Contractor shall produce
model of product with manufacture certificate or equivalent guide line.

b) 50 mm dia. brass non-return


Inspection Pit:

Construction of masonry inspection pits inside measurement are given below, with 150 mm thick brick work in
cement mortar (1:4) with 100 mm thick R.C.C. top slab (1:2:4) with 1% reinforcement, 450mm dia water
sealed R.C.C. M.H. cover in/c. necessary earth work, side filling and one brick flat soling, 75mm thick (1:3:6)
base concrete for making invert channel and 12 mm thick (1:2) cement plaster with neat finishing etc. all complete
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

a). (600 x 600 mm)


c) (1800 x 1800mm)
Construction of septic tank with walls of brick work in cement mortar (1:6) having a lining of minimum
125 mm R.C.C cast against the walls as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Construction of Water Meter Pit as per design, drawing, specification of relavant chapter
and accepted by the Engineer.
Sensor Wall Hung Toilet: (Handicap Type)
Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain closed coupled
Sensor Wall Hung (Handicap Type) Commode ‘P’ or ‘S’ type with low down/flush tank and flush valve
including all internal fittings as per design, drawing, specification of relavant chapter and accepted by the
Engineer.
TOTO, Duravit or Equivalent / Japanese or Europian Origin of approximate size
(525mm x 415mm x 860mm)
Wall Hung Lavatory: (Handicap Type)
Supplying, fitting and fixing foreign made best & approved quality Wall Hung Lavatory:
(Handicap Type) including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Toto. Duravit or Equivalent / Japanese or European Origin of approximate size
(530mmx430mmx220mm)
Piller Cock: (Handicap Type)
Supplying, fitting and fixing foreign made best & approved quality Piller Cock: (Handicap Type)
including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

TOTO, Grohe, Hans Grohel or Equivalent / Japanese or European Origin of approximate


size (530mmx430mmx220mm)

Supplying, fitting and fixing foreign made best & approved quality Grab Bar Flip Type (Handicap Type)
including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

TOTO, Grohe, Hans Grohel or Equivalent / Japanese or European Origin.


Grab Bar "L" Shape
Supplying, fitting and fixing foreign made best & approved quality Grab Bar "L" Shape
(Handicap Type) including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
TOTO. Grohe, Hans Grohel or Equivalent / Japanese or European Origin of approximate
size (w:700×d:700mm(120mm away from the wall))

Internal Electrification Works

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following lighting switches, including all necessary cable, termination, concealed GI conduit and
accessories as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

1-Way, 1 gang, lighting switch


1-Way, multi gang, lighting switch
2-Way, 1 gang, lighting switch
2-Way, multi gang, lighting switch
1-Way, 1 gang, metal clad, lighting switch
1-Way, multi gang, metal clad, lighting switch
2-Way, 1 gang, metal clad, lighting switch
2-Way, multi gang, metal clad, lighting switch
Lighting switch wiring point consist of 2x2.5sqmm PVC E and conduit. (Each point does
not exceed 20m), work should be done as per design, drawing, specification of relevant chapter and accepted by
the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the motion detector for toilets, including all necessary cable, termination, concealed GI conduit and
accessories as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following switch socket outlet (S/S/O), including all necessary cable, termination, concealed GI
conduit and accessories as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

1x16A recess mounted universal s/s/o


2x16A recess mounted universal s/s/o
1x16A metal clad recess mounted s/s/o
2x16A metal clad recess mounted s/s/o
1x16A universal s/s/o mounted in underfloor trunking junction box
2x16A universal s/s/o mounted in underfloor trunking junction box (provision)
Wiring point consist of 2x4sqmm PVC + 4sqmm PVC E (Each point does not exceed
70m)
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the hand dryer, including all necessary cables, termination, concealed GI conduit and accessories on
Ground Floor, work should be done as per design, drawing, specification of relevant chapter and accepted by the
Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the invalid toilet warning system, including all necessary buzzer, strobe light, cable, termination,
concealed GI conduit and accessories on Ground Floor, work should be done as per design, drawing, specification
of relevant chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following isolator, including all necessary cable, termination, cable supporting and accessories where
required, work should be done as per design, drawing, specification of relevant chapter and accepted by the
Engineer.
20A DP Isolator
63A DP Isolator
100A DP Isolator
20A 4P Isolator
32A 4P Isolator
40A 4P Isolator
63A 4P Isolator
80A 4P Isolator
100A 4P Isolator
20A DP Switch

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the termination block, including all necessary cable, termination, cable supporting and accessories as
specified and complying with relevant codes, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

16A switch socket outlet universal type duplex for FIDS (UPS)
i. Column mounted or Wall mounted
ii. Ceiling mounted (metal clad)
iii. Floor mounted
16A switch socket outlet universal type duplex for CCTV (UPS)
i. Columned mounted(WP)
ii. Column mounted and wall mounted
iii. Ceiling mounted (metal clad)
16A switch socket outlet universal type duplex for Card Access System (UPS)
i. Column mounted or Wall mounted
ii. Ceiling mounted (metal clad)
iii. Floor mounted
16A switch socket outlet universal type duplex for Security Scanning
Equipment (Floor mounted)
16A metal clad switch socket outlet universal type duplex for maintenance of Escalator
pit (floor mounted) (Emergency)
16A switch socket outlet universal type duplex for Clock System (UPS)
i. Column mounted and wall mounted
16A switch socket outlet universal type duplex for Master Antenna TV System
(Column mounted & Wall
16A switch socket outlet universal type duplex for Signage (Emergency)
i. Floor mounted
ii.Wall mounted
ii. Ceiling mounted (metal clad)
16A metal clad switch socket outlet universal type duplex for Auto sliding doors
(Ceiling Mounted) (UPS)
16A metal clad switch socket outlet universal type duplex for Auto sliding doors
(Floor Mounted) (UPS)
16A switch socket outlet universal type duplex for Water Cooler (Normal)
16A switch socket outlet universal type duplex for Public Telephone (Normal)
Supply and installation of hand dryer complete with 16A metal clad switch socket outlet universal type, work
should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Supply and installation of single socket outlet complete with cabling tapping from emergency source for twin head
20watt emergency battery pack floodlights, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

INTERNAL LIHTING

Supply, delivery, installation, testing and commissioning of the following type of Luminaires, including all cabling
works, termination, ceiling roses in ceiling space, concealed GI conduit, junction box complete with quick male &
female connector, supporting brackets and necessary accessories and link to respective lighting switches as
specified and complying with relevant codes, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

20W LED Frameless Line Light


Frameless panel having L 1195mm*W 295mm *H16mm with PMMA diffuser light guide acrylic plate with fire-
proof function.
Ceiling LED luminaires with hidden aluminum frame in high value design. Ceiling mounting or pendant
mounting, Stainless rope with length adjustable.
Lumen output:110lm/w, CRI(Ra)> 80.
Life time should be more than 50,000 hrs. Color temperature:3000k- 6500K; Operating Voltage: 85~265V,
Power factor=0.95

20W Down Light


Recessed LED downlight. . IP54 (IP20 from above). Body: Pressure die cast aluminum housing with full diffused
recessed mounted LED.Complete with 6500K LED.
Total power: 20 W
Luminaire luminous flux:2200 lm Lumen output:114-127 lm/W Operating Voltage: 85- 265 VAC
CRI:80;CCT:6500K
Life time:30,000-35,000 Hours

2'x2' Panel light 48W


Recessed LED Panel Light . IP54 (IP20 from above) 41 W fully diffused recessed mounted LED luminaire
(595X595mm)
with Extruded aluminum housing. Total Power : 41W,
Luminaire luminous flux: 4500 lm Operating Voltage: 85-265 VAC Efficacy:110-127 Lm/W
CRI: 80, CCt:6500K
Life time: 40,000-50,000 Hours PF:0.95

28W Down Light


A recessed LED downlight. . IP54 (IP20 from above). Body: Pressure die cast aluminum housing with full
diffused recessed mounted LED. Suitable for mounting in ceiling thicknesses of 1-40mm in a Ø136 mm cut-out.
Complete with 6500K LED.
Total power: 28W
Luminaire luminous flux: 3130 lm Lumen output:114-127 lm/W Operating Voltage: 85- 265 VAC
CRI:80;CCT:6500K
Life time: 40,000-50,000 Hours PF:0.95
i) 150W High Bay
ii) 150W High Bay
2x20W LED Tube Light (40W) Water Proof T8 Tube Light Fixture Housing material ABS+PS. Suitable 2x20
W T8 Tubelight .
Lumen output:110-127lm/W Operating Voltage: 85-265 VAC CRI:80;CCT:6500K Life time: 40,000-50,000 Hours
PF:0.95
EXIT LED c/w 2 hours battery pack backup, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.
Wiring point consist of 2x2.5sqmm PVC + 2.5sqmm PVC E and conduit (Each point does not exceed 10m), work
should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

Electrical Substation works


SUBSTATION
Supply, delivery, installation, testing and commissioning of DROP OUT FUSE for Main incoming Feeder in
Utility Station, work should be done as per design, drawing, specification of relevant chapter and accepted
by the Engineer.:
Rated Voltage(Nominal) : 12KV
Number of Phase 3
System frequency : 50Hz

Supply, delivery, installation, testing and commissioning of LIGHTNING ARRESTER for Main incoming
Feeder in Utility Station, work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.:
Rated Voltage(Nominal) : 12KV
Number of Phase 3
System frequency : 50Hz

Supply, delivery, installation, testing and commissioning of HT Cabling between HT Switchgear in Utility
Station and HT Switchgear in PTB Building and control tower, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

4 sets of 3x185mmsq 1C CU/XLPE/AWA/PVC 11KV power distribution cable in underground cable duct
linking from HT panel in Main 11KV Utility Station to HT panel in the PTB building and control tower. It shall
also include pilot cable, cable support, terminations, mounting, labelling, associated accessories and building
works necessary to provide the complete system as specified and complying with relevant codes.

HT (11KV) SWITCHGEAR (VCB) FOR INCOMING FEEDER(MAIN):


Supply, delivery, installation, testing and commissioning of (MAIN HT SW/BD) 12KV Incoming Feeder Air
Insulated Switchgears c/w Vacuum Circuit Breaker, protection relays including all Airport Operation
Readiness Trials. It shall also include BMS interfacing modules, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the complete
system as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

HT (11KV) SWITCHGEAR (VCB)FOR OUTGOING FEEDER:


Supply, delivery, installation, testing and commissioning of (MAIN HT SW/BD) 12KV Incoming Feeder Air
Insulated Switchgears c/w Vacuum Circuit Breaker, protection relays including all Airport Operation
Readiness Trials. It shall also include BMS interfacing modules, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the complete
system as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
HT (11KV) SWITCHGEAR (VCB)FOR INCOMING:
(UTILITY STATION TO PTB BUILDING, UTILITY STATION TO CONTROL TOWER AND AGL TO
CONTROL TOWER)
Supply, delivery, installation, testing and commissioning of (MAIN HT SW) 12KV Incoming Feeder Air
Insulated Switchgears c/w Vacuum Circuit Breaker, protection relays including all Airport Operation
Readiness Trials. It shall also include BMS interfacing modules, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the complete
system as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

TRANSFORMER

2000kVA THREE PHASE DRY TYPE TRANSFORMER(PTB)


Supply, delivery, installation, testing and commissioning of dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV
& 0.24 KV indoor type distribution transformer of DYN11 vector group having percentage impedance 4-
6.5%, basic impulse insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer,
complete with two windings of high conductivity copper, earthing terminals, temperature sensor with
thermometer, thermostat controlled blower fan (if required), lifting lugs, data plate etc. complete as required with
maximum 600C temperature rise and suitable for operation at
400 C ambient temperature manufactured & tested or equivalent approved by the Engineering-in-Charge in
accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

2500kVA THREE PHASE DRY TYPE TRANSFORMER(UTILITY STATION)


Supply & installation of Following type dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV & 0.24 KV indoor
type distribution transformer of DYN11 vector group having percentage impedance 4-6.5%, basic impulse
insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer, complete with two
windings of high conductivity copper, earthing terminals, temperature sensor with thermometer, thermostat
controlled blower fan (if required), lifting lugs, data plate etc. complete as required with maximum 600C
temperature rise and suitable for operation at 400 C ambient temperature manufactured & tested and approved
by the Engineering-in-Charge in accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done
as per design, drawing, specification of relevant chapter and accepted by the Engineer.

2000kVA THREE PHASE DRY TYPE TRANSFORMER(UTILITY STATION)(STEP UP)


Supply, delivery, installation, testing and commissioning of dry type cast resin 3-phase, 50Hz, 0.415 KV/11KV
indoor type distribution transformer having percentage impedance 4-6.5%, basic impulse insulation level 75
KV, HV & LV bushings, manual 5 position standard tap changer, complete with two windings of high conductivity
copper, earthing terminals, temperature sensor with thermometer, thermostat controlled blower fan (if
required), lifting lugs, data plate etc. complete as required with maximum 600C temperature rise and suitable for
operation at 400 C ambient temperature manufactured & tested and approved by the Engineering-in-Charge in
accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
500kVA THREE PHASE DRY TYPE TRANSFORMER(CONTROL TOWER)
Supply & installation of Following type dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV & 0.24 KV indoor
type distribution transformer of DYN11 vector group having percentage impedance 4-6.5%, basic impulse
insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer, complete with two
windings of high conductivity copper, earthing terminals, temperature sensor with thermometer, thermostat
controlled blower fan (if required), lifting lugs, data plate etc. complete as required with maximum 600C
temperature rise and suitable for operation at 400 C ambient temperature manufactured & tested by Trafo-Union
(Germany) /Trihal (France)/ Alstom (EU)/Thesar (Italy) or equivalent approved by the Engineering-in-Charge in
accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

315kVA THREE PHASE DRY TYPE TRANSFORMER (CONTROL TOWER)


Supply & installation of Following type dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV & 0.24 KV indoor
type distribution transformer having percentage impedance 4- 6.5%, basic impulse insulation level 75 KV,
HV & LV bushings, manual 5 position standard tap changer, complete with two windings of high conductivity
copper, earthing terminals, temperature sensor with thermometer, thermostat controlled blower fan (if
required), lifting lugs, data plate etc. complete as required with maximum 600C temperature rise and
suitable for operation at 400 C ambient temperature manufactured & tested by Trafo-Union (Germany) /Trihal
(France)/ Alstom (EU)/Thesar (Italy) or equivalent approved by the Engineering-in-Charge in accordance
with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

315kVA THREE PHASE DRY TYPE TRANSFORMER STEP UP (CONTROL TOWER)


Supply, delivery, installation, testing and commissioning of dry type cast resin 3-phase, 50Hz, 0.415KV/11KV
indoor type distribution transformer of DYN11 vector group having percentage impedance 4-6.5%, basic
impulse insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer, complete with two
windings of high conductivity copper, earthing terminals, temperature sensor with thermometer, thermostat
controlled blower fan (if required), lifting lugs, data plate etc. complete as required with maximum 600C
temperature rise and suitable for operation at 400 C ambient temperature manufactured & tested and approved
by the Engineering-in-Charge in accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done
as per design, drawing, specification of relevant chapter and accepted by the Engineer.

GENERATORS

Supply, delivery, installation, testing and commissioning of 1600 KVA 400 / 230 V, 3-phase, 50 Hz. air/water
cooled, floor mounted, indoor type following continuous capacity (Prime Power) electric generating set
suitable for tropicalized country complete with four stroke, 1500 rpm, diesel engine with all standard accessories,
viz. 12/24 volt DC battery & auto battery charger with ammeter, radiator assembly, oil & fuel pump, auto
speed governor, air cleaner, fuel & oil tank, fuel level & oil pressure gauge, RPM & hour meter, exhaust silencer,
vibration isolator, mounting steel base frame etc including a safety & protection device viz. auto shut off with
indicators for overload, over & under voltage high temperature, low oil pressure, over speed, low fuel level etc.
coupled with brush less, self excited alternator having control panel with auto voltage regulator, voltmeter
& ammeter with selector switch, frequency meter and work should be done as per design, drawing, specification
of relevant chapter and accepted by the Engineer.
Supply, delivery, installation, testing and commissioning of 1000 KVA 400 / 230 V, 3-phase, 50 Hz. air/water
cooled, floor mounted, indoor type following continuous capacity (Prime Power) electric generating set
suitable for tropicalized country complete with four stroke, 1500 rpm, diesel engine with all standard accessories,
viz. 12/24 volt DC battery & auto battery charger with ammeter, radiator assembly, oil & fuel pump, auto
speed governor, air cleaner, fuel & oil tank, fuel level & oil pressure gauge, RPM & hour meter, exhaust silencer,
vibration isolator, mounting steel base frame etc including a safety & protection device viz. auto shut off with
indicators for overload, over & under voltage high temperature, low oil pressure, over speed, low fuel level etc.
coupled with brush less, self excited alternator having control panel with auto voltage regulator, voltmeter
& ammeter with selector switch, frequency meter and work should be done as per design, drawing, specification
of relevant chapter and accepted by the Engineer.

TP MCCB of required rating for overload & instantaneous short circuit release , auto start & auto change
over to load within 10 sec during normal power failure and auto stop & auto change over to normal supply within
5 minutes after restoration of normal power supply, indicator for 3 Phase ON-OFF - Trip etc including
maintenance tools, 3 sets of detailed technical catalogues & maintenance manual. Manufactured, assembeled
and tested in accordance with NEMA / IEC / VDE / JIS standards, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

The generating set shall be assembled & tested in USA/Japan/EU countries. The major components like
engine,alternator, ATS, canopy shall also be manufactured and tested in USA/ Japan/ EU Countries &
accepted/approved by the Engineer and work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the cabling works with 1C-300 sqmm, NYY/XLPE cable from the standby generating set to control
panel as specified and work should be done as per design, drawing, specification of relevant chapter and accepted
by the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the 20,000 litres underground fuel storage tank of capacity as specified c/w level indicators, fuel
pipes, vent pipes, reinforcement concrete pit, maintenance manhole and all necessary safety and control devices as
specified and work should be done as per design, drawing, specification of relevant chapter and accepted
by the Engineer.

Supply, delivery and installation of reinforced concrete re-fuelling pit c/w chequer plate cover, work should be
done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.
Supply, delivery, installation, testing and commissioning 250 KVA AVR for Fire
Fighting Building and work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.
LT Distribution Board

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following LT Switchboards. It shall also include protection relays, surge arrestors, electrical & signal
cabling, cable support, terminations, mounting, labelling, associated accessories and building works necessary to
provide the complete system as specified and complying with relevant codes, work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.
LT-4000A(Type tested assembly):
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor mounting type
completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard drawn electrolytic copper bus bars
(TPN+50%E) placed on porcelain insulator. Including cable color coding, cable lugs, Cable gland, nut, bolts and
washer and modern locks.The board is designed and constructed in accordance with BNBC-2014 & IEEE
Electrical wiring.And shall have type test certificate of switchgear from reputable international laboratory
(KEMA, ASTA OR ASIFA shall be submitted at the time of technical submission.
The switchgear shall include the following components: INCOMING:
2 No. 4000A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 4 Nos. Current transformer,
ratio 4000/5A with suitable accuracy and burden.
4 Nos. Ammeter scaled 0-4000A.
2 No. Voltmeter scaled 0-600V with selector switch. 4 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No. 3200A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 1 No. 1000A 35KA, 415V,
50Hz, TP ACB with Necessary controlling & protection option. 1 No. 800A 35KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip.
4No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 250A 25KA, 415V, 50Hz, TP
MCCB with thermal over load & magnetic trip. 1 No. 160A 25KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 1 set of control MCB.

LT-3200A(Type tested assembly):


Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor mounting type
completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard drawn electrolytic copper bus bars
(TPN+50%E) placed on porcelain insulator. Including cable color coding, cable lugs, Cable gland, nut, bolts and
washer and modern locks.The board is designed and constructed in accordance with BNBC-2014 & IEEE
Electrical wiring.
The switchgear shall include the following components: INCOMING:
2 No.3200A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 4 Nos. Current transformer,
ratio 3200/5A with suitable accuracy and burden.
4 Nos. Ammeter scaled 0-3200A.
2 No. Voltmeter scaled 0-600V with selector switch. 4 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1No. 3200A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 1 No. 2000A 35KA, 415V,
50Hz, TP ACB with Necessary controlling & protection option. 2 No.1000A 35KA, 415V, 50Hz,TP ACB with
Necessary controlling & protection option. 1No.800A 35KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip.
1No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 1No.400A 35KA, 415V, 50Hz, TP
MCCB with thermal over load & magnetic trip. 5 No. 250A 25KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 1 No. 125A 25KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 1 set of control
MCB.
LT-1600A(TTA):
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding, cable
lugs, Cable gland, nut, bolts and washer and modern locks.The board is designed and constructed in accordance
with BNBC-2014 & IEEE Electrical wiring.And shall have type test certificate of switchgear from
reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of technical
submission.
The switchgear shall include the following components: INCOMING:
2 No.1600A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option.
1 No.1000A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option.
6 Nos. Current transformer, ratio 1600/5A with suitable accuracy and burden. 6 Nos. Ammeter scaled 0-1600A.
3 No. Voltmeter scaled 0-600V with selector switch. 6 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1 No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 7 No. 250A 25KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 1 No. 160A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 1 set of control MCB.

LT-800A(TTA):
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding, cable
lugs, Cable gland, nut, bolts and washer and modern locks.The board is designed and constructed in accordance
with BNBC-2014 & IEEE Electrical wiring.And shall have type test certificate of switchgear from
reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of technical
submission.
The switchgear shall include the following components: INCOMING:
2No.800A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 4 Nos. Current
transformer, ratio 1600/5A with suitable accuracy and burden.
4Nos. Ammeter scaled 0-1600A.
2 No. Voltmeter scaled 0-600V with selector switch. 4 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1 No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 250A 25KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 2 No. 160A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 4 No. 100A 25KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 1 set of control MCB.

PFI Plant
1500KVAR PFI Plant

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

1200KVAR PFI Plant


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

380 KVAR PFI Plant

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

190 KVAR PFI Plant

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

Distribution Boards
Distribution Boards (PTB)-MDB-800A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 800A)(Type tested assembly) . It shall also
include protection relays, electrical & signal cabling, cable support, terminations, mounting, labelling,
associated accessories and building works necessary to provide the complete system as specified and
complying with relevant codes, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 800A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.The board is designed and constructed in
accordance with BNBC-2014 & IEEE Electrical wiring.And shall have type test certificate of switchgear
from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of technical
submission.
INCOMING:
1 No. 800A 50KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 800/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-800A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
8No.250A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4 No. 200A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 160A 35KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 2 No. 100A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 1 set of control MCB.

MAIN DISTRIBUTION BOARD-630A


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 630A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 630A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1 No. 630A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 630/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-630A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1No.250A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
1No. 160A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 100A 35KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 2 No. 63A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip.
2 No. 32A 25KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 1 set of control MCB.

MAIN DISTRIBUTION BOARD-400A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 400A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1 No. 400A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 400/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-400A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No.100A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4No. 63A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 40A 25KA, 415V, 50Hz,
TP MCCB with thermal over load & magnetic trip. 5 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over
load & magnetic trip.
5 No. 20A 16KA, 415V, 50Hz,DP MCB with thermal over load & magnetic trip. 1 set of control MCB.

MAIN DISTRIBUTION BOARD-250A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 250A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1 No. 250A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 250/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-250A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1No.100A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4No. 63A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 40A 25KA, 415V, 50Hz,
TP MCCB with thermal over load & magnetic trip. 5 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over
load & magnetic trip.
5 No. 20A 16KA, 415V, 50Hz,DP MCB with thermal over load & magnetic trip. 1 set of control MCB.

FLOOR DISTRIBUTION BOARD-250A


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 250A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.
The switchgear shall include the following components: INCOMING:
1 No. 250A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
2Nos. Current transformer, ratio 250/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-250A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No.200A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
2No. 100A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 63A 25KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 50A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 4 No. 32A 16KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 4 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over load & magnetic trip.
2 No. 32A 16KA, 415V, 50Hz,DP RCBO
1 set of control MCB.

FLOOR DISTRIBUTION BOARD-100A-160A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 160A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1No. 160A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 160/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-160A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No.63A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4No. 40A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 8 No. 32A 16KA, 415V, 50Hz,
TP MCCB with thermal over load & magnetic trip. 4 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over
load & magnetic trip. 1 set of control MCB.

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Sub Distribution Switchboards(Type tested assembly)
. It shall also include protection relays, electrical & signal cabling, cable support, terminations, mounting,
labelling, associated accessories and building works necessary to provide the complete system as specified in
drawing and complying with relevant codes, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

DB-Type-01(As per Drawing)


DB-Type-02(As per Drawing)
DB-Type-03(As per Drawing)
DB-Type-04(As per Drawing)
DB-Type-05(As per Drawing)
DB-Type-06(As per Drawing)
CABLE FOR DISTRIBUTION SYSTEM (work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.)
5X4x1C-500 sq. mm (XLPE) with 3x1C-300 sq. mm (BYA) ECC
7X4x1C-500 sq. mm (XLPE) with 3x1C-300 sq. mm (BYA) ECC
5X4x1C-400 sq. mm (XLPE) with 3x1C-240 sq. mm (BYA) ECC
4x4x1C-500 sq. mm (XLPE) with 2x1C-300 sq. mm (BYA) ECC
4x1C-400 sq. mm (XLPE) with 1C-240 sq. mm (BYA) ECC
2X4x1C-300 sq. mm (XLPE) with 1C-300 sq. mm (BYA) ECC
4x 1C-300 sq. mm (XLPE) with 1C-150 sq. mm (BYA) ECC
4x1C-120 sq. mm (XLPE) with 1C-70 sq. mm (BYA) ECC
4x1C-95 sq. mm (XLPE) with 1C-50 sq. mm (BYA) ECC
4x1C-70 sq. mm (XLPE) with 1C-35 sq. mm (BYA) ECC
4 x 1C-50 sq. mm (XLPE) with 1C-25 sq. mm (BYA) ECC
4x 1C-35 sq. mm (XLPE) with 1C-16 sq. mm (BYA) ECC
4x 1C-25 sq. mm (XLPE) with 1C-16 sq. mm (BYA) ECC
4x1C-16 sq. mm (XLPE) with 1C-16 sq. mm (BYA) ECC
Cable Support (work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.)
300mmx100mm cable trunking
150mmx100mm cable trunking
75mmX50mm cable trunking
6x700mm Cable Lader
450mmx100mm cable Tray
2x600mm Cable Tray
2x300mm Cable Tray
150mm Dia PVC Pipe
UPS

Supply, delivery, installation, testing and commissioning of the following unit of complete IGBT
uninterruptiable power supply system c/w all necessary control and mimic panels including all Airport
Operation Readiness Trials. It shall also include internal static bypass circuitry, isolation transformer at the
output, earthing, BMS interfacing modules, electrical & signal cabling, cable support, terminations, mounting,
labelling, associated accessories and building works necessary to provide the complete system as specified
and complying with relevant codes, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

UPS-U1 (120kVA)

Supply, delivery, installation, testing, commissioning, including all Airport Operation Readiness Trials for the
following Sub Distribution Switchboards in Main Terminal. It shall also include protection relays, BMS
interfacing modules, electrical & signal cabling, cable support, terminations, mounting, labelling,
associated accessories and building works necessary to provide the complete system as specified and
complying with relevant codes, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

EDB-UPS

Supply, delivery, installation, testing, commissioning, including all Airport Operation Readiness Trials for
the following Distribution Boards in Main Terminal. It shall also include protection relays, BMS
interfacing modules, electrical & signal cabling, cable support, terminations, mounting, labelling,
associated accessories and building works necessary to provide the complete system as specified and
complying with relevant codes, work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.

DB TYPE : 07
DB TYPE : 08
2 x 25sqmm 1C FR + 16sqmm 1C PVC E

ADDRESSABLE FIRE DETECTION & ALARM SYSTEM


Addressable Fire Alarm Control Panel (FACP)

Supply and installation of Microprocessor based Fire Alarm Control Panel (FACP) which shall be capable to
handle at least 127 devices (Up to 127 Detector & Modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop) per loop.

The FACP shall provide the following features:


4 No of Loop SLC
4 No of NAC Ckt.
Large 8-line x 40-character LCD display (320 char.)
Minimum loop length 1.6km
Built-in Alarm, Trouble and Supervisory relays.
Soft address function
History File
Easy to add/remove devices
Automatic day/night sensitivity adjustment
Status LEDs to easily identify system status
Auto-learn feature, Fire Drill test function, Walk Test function
Capable to networking with other FACP and Repeater Panel
Built-in in battery charger
Battery capacity: as per battery calculation (shall be done by Vendor)
Approvals: UL Listed, FM approved.
Addressable Fire Alarm Repeater Panel (FARP)
Supply & installation of addressable type repeater panel for mimicking Main Fire Alarm
Control Panel data.
The FARP shall provide the following features:
320 character liquid crystal display (8 line x 40 character)

LED indicators for Fire, Supervisory Alarm, Pre- Alarm, Fire Output Active, Power On, On Test, Panel Sounder
Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System
Trouble & NAC Trouble

Capable to networking with FACP


Approvals: UL Listed, FM approved.
External Power Supply
Supply and installation of External power supply unit with all other accessories from the same Manufacturer of
FACP. It shall be used for providing power to Notification
appliances.
The Power Supply shall provide the following features:
6 No of NAC Ckt.
Capacity: To power up to 10 Horn & Strobe per NAC Ckt.
Quadrasync provides panel wide synchronization of the same or multiple brands
Configurable output circuits (DIP switch sets options for each circuit)
Built-in in battery charger
Supports 7 - 55AH batteries
Approvals: UL Listed, FM approved.
Addressable Manual Call Point (MCP)
Supply and installation of addressable type manual call point like single action/double pull station complete
with back box and all other accessories and consumables.

The MCP shall provide the following features:


Bi-colored status LED indicates Standby and Alarm conditions
Address is programmable in EEPROM
Approvals: UL Listed, FM approved.
Addressable Optical Smoke Detector (SD)
Supply and installation of Microprocessor based addressable Optical Smoke Detector.
The SD shall provide the following features:
Detector sensitivity must be programmed in the control panel software
Sensitivity must be continuously monitored and reported to the panel.
Two built-in power/alarm LEDs
Non-directional smoke chamber
Approvals: UL Listed, FM approved.
Addressable Heat Detector (HD)
Supply and installation of Microprocessor based addressable Fixed temperature & rate of
rise thermal detector.
The HD shall provide the following features:
Rate of Rise temperature threshold = 15°F/Min
Adjustable threshold temperature = 135°F - 190°F
Detector sensitivity must be programmed in the control panel software.
Two built-in power/alarm LEDs
Approvals: UL Listed, FM approved.
Addressable Duct Detector (DD)
Supply and installation of Microprocessor based addressable Duct detector.
The DD shall provide the following features:
Detects and limits the spread of smoke throughout building HVAC ducts
No screens or filters to clean
Approvals: UL Listed, FM approved.
Conventional Electronic Strobe with Sounder
Supply and installation of conventional Electronic Strobe with Sounder for Visible &
Audible application which shall have field-selectable candela & volume settings
The Strobe with Sounder shall provide the following features:
Switch Selection for High or Low dBA
Switch Selection for 2400Hz or Mechanical Tone
Min. Sounder Output: 81dBA @ 10ft
Min. Candela Output: 15cd
Approvals: UL Listed, FM approved.
Addressable Input Module

Supply & Installation of Addressable input Module which shall be used in the field wiring to connect the to
additional devices (i.e. Fire Pump, Fire Pump Panel, Control Valves, Sprinkler Zone Control Valves, Duct
Detector, etc... ) with the Addressable FACP interfaces to make the system convenient as when as required.

The Input Module shall provide the following features:


The module shall be suitable for double address to the FACP on receiving both alarm &
fault signal form any electrical/electro mechanical.
Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
Approvals: UL Listed, FM approved.
Addressable Output Module
Supply & Installation of Addressable type relay output module which shall be used in fire alarm system to
integrate with lift control systems, exhaust fan panel, fire door, HVAC, Escalator, Conveyer Belt, Access Control
Door, PA System, etc.
The Output Module shall provide the following features:
Provides two independently configurable Form C contacts per address
Programming is highly flexible providing 16 priority
states plus zoning capability
Approvals: UL Listed, FM approved.
Short Circuit Isolator (SCI)
Supply & Installation of Short Circuit Isolator
The SCI shall provide the following features:
Can be placed at any location on SLC loop
Checks the line for short circuit at power up. If the line is normal, the relay will be returned on. If a line short is
detected, the relay remains open
Approvals: UL Listed, FM approved.
Cabling & Conduit Works
Supply & installation of PVC insulated PVC sheathed copper conductor single / multicore FP (fire proof) cable
complete with PVC conduit or GI pipe. Conduit works
shall be complete with Bends, Tees, Junction box, etc.
i) 2x1.5mm2 (FR)+1.5AL (Foil) FP-200 c/w 20mm pVC conduit
ii) 2x2.5mm2 (FR)+1.5AL (Foil) FP-200 c/w 20mm pVC conduit
Fire Monitoring/SCADA System

Supply & Installation of Fire Monitoring System to represent fire device status in a graphical interface.
- Extensive logging of events and operations
- User friendly installation and configuration
- Monitoring Station(Desktop Computer) (including required interfacing devices & Software)
SEWAGE TREATMENT PLANT

Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant (STP) capacity 350
m3/day. The plant proposed shall be a common pump room in near of STP. The plant is proposed to be
installed in the ground accessible for future maintenance.

Nature of effluent-Domestic Sewage( Toilet: Black & Grey Water) from each tiolet of
individual building use to STP
Daily average flow : 350 m3/day
Nature of effluent - Sewage
Influent Characteristics
pH - 7.5 - 8.5
BOD5 - upto 200-250 Mg/L
S. Solids - 200- 400 Mg/L
COD - upto 400-500 Mg/L
Oil & Grease - 30 Mg / L
Effluent discharge standard after treatment
pH - 6.5 - 8.5
BOD - Less than 10 mg/L
TSS - Less than 10 mg/L
COD - Less than 75 mg/L
Oil & Grease - < 2 Mg / L
Residual Chlorine- Less than 10 mg/L
Colifrom- Less than 100 counts/100 ml (desired nil)
Sewage treatment plant shall include the following items
a). Screen Chamber / Oil and Grease Chamber
b). Equalization / Collection Tank
c). Aeration TANK
d). Secondary Settling tank
e).Treated Effluent Tank
f). Sludge Holding Tank
g). Filtration through MGF (Multigrade Filter) & ACF (Activated Carbon Fibres)
h). Air Blowers, Pumps & equipment
i). Piping, valves etc
j).Electrical Panel & Cabling
k).Common plant room adjacent to STP.
l). All piping, valves & level indicator/controller etc. within plant room.

Supply, installation, testing & commissioning of one nunber Stainless Steel Perforated Screen with suitable
lifting arrangement mechanically (size 600mm wide x 1000mm high approx) Barsizing will be 40mm x 6mm &
Bar spacing should be min 15mm

Supply, installation, testing & commissioning of electronic type level indicator and controller for automatic
operation of the system with high/low level alarm complete with
auxillary NO/NC (Normally Open/Normally Closed) Contacts

Supply, installation, testing & commissioning of non clogging type pumps, having CI casing & SS shaft,
bronze impeller complete with all accessories, motor of required capacity. Delivery header with isolation
valve/NRV etc, pressure gauge on delivery line with isolation cock level controller with wiring to
control the level of sump automatically. Pump shall have following duty :
i) Submersible Sump Pumps for equilisation tank/Sewage lifting pump (2Nos.-1working
& one standby) :-
Flow rate (each) = 20 m3 / hr
Head = 10-15 Meter
ii) Submersible Solid handling Pumps (2 Nos.- 1 working + 1 standby)
Flow rate (each) = 4 m3/hr
Head = 5-10 Mts

iii) Sludge Recirculation Pumps (2Nos.-1working & one standby) :-


Flow rate (each) = 4 m3 / hr
Head = 5-10 Mtr
Air diffusion system shall include the following:

Twin type rotary air blowers (1working & 1 standby) capable of delivering 200 m3/hr (each) or required
capacity of free air at 0.55kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC
("Totally Enclosed, Fan Cooled") motor of suitable HP Suitable for 415±10% volts, 3 phase, 50 cycles a/c supply

Air piping shall comprise of pipes droppers/laterals with MS (epoxy coated) Header complete with all
fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports
& clamps, puddle flanges etc cutting chases & making good.
Non clog type air dispersion system capable of handling 3-5 cfm or required capacity of air with oxygen transfer
efficiency of 3-4% per/meter water depth. Air dispersion grid
shall be assembled in modular form so that they can be replaced / repaired
Fine bubble diffusers required Nos
i) For Equalization / Collection Tank -1 Nos.
ii) For Sludge Holding Tank - 1 No.
iii) Aeration Tank- 1Nos.
Air dispersion system shal lbe provided for Equalisation Tank, Sludge holding Tank and
Aeration Tank.
Providing and fixing all piping (as described below) and isolation control valves form
making thes ystem complete.
SS 304 : Submerged air piping
MS Epoxy : Air piping
PVC piping: Pumped effluent & tank over flow pipe line
Supply, installation, testing and commissioning of circular floating type media to be
installed in Aeration Tank (1Nos.) and PVC tube deck settling media to be installed in Secondary Settling Tank
along with suitable sludge removal arrangement.

Supplying, installing, testing & commissioning of filter feed water pumps CI Body, SS shaft, bronze Impeller
with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery
line. Isolation valve, stainer at suction. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c
supply

Capacity : 15 m3/hr.
Head : 15-20 meter
No. of Pumps (1 working + 1 standby)
Operation of pump shall be based on level controller proposed to be installed in tank as per site location. The
contractor to ascertain the Head required for pumps as per site
conditions and provide accordingly
Supplying, installing, testing and commissioning of FRP vessel filter with frontal piping
and associated valves and accessories. Filter shall be suitable for minimum working pressure of 5kg/cm2
and shall include media, standard fittings like pressure.
i) Multigrade pressure sand filter media
Flow rate : 15 cum/hr
Filteration velocity : 12 cum/hr/sqm
Filter Diameter : 1000 mm.
ii) Activated Carbon Filter
Flow Rate : 15 cum/hr
Filteration velocity : 12 cum/hr/sqm
Filter Diameter : 1000 mm
Contractor may be asked to alter the number of filters and pumps subject to any revision
to meet the desired capacities.

Supply, installation, testing & commissioning of water softening plant (FRP)for making up of water for cooling
tower and toilet flushing comprising of multiport valve with brine ejection and plastic piping complete with brine
tank with fitting & brine fitting filtering media and complete charge of cation exchange resine as given below
(incoming hardnes 350 PPM).

Water Flow : 15 m3/hr for 8 hr.


(Incomming Hardness 350mg/lit (Approx))
Working Pressure 3.0 Kg/Cum
Outgoing hardness less than 50 ppm
Water Softening plant as described above

Supply, installation, testing and commissioning of Filter Press of plate size 16"x16" plate with screw feed pumps
for required capacityas/requirment (1Working+1Standby), with interconnecting piping and poly dosing system
all complete.

Supply, installation, testing & commissioning of Booster pump with CI Body, SS shaft, Bronze Impeller with
mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line.
Isolation valve, stainer at suction. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c supply

i) For reuse for toilet Flashing


Capacity : 35 m3/hr.
Head : 80 meter
No. of Pumps (4 working + 1 standby)
ii) For Cooling Tower
Capacity : 5 M3/hr.
Head : 45 M
No. of Pumps (1 working + 1 standby)
Providing & fixing bypass line with arrangement of valve from equilization tank, tank to
out side sewer manhole/ for tanker connection.
Supply, installation, testing & commissioning of pH Meter, Electronic megnetic flow
meter in inlet & outlet of filtration system complete in all respect.
Supply, installation, testing and commissioning of Energy Meter for electrical panel of
STP complete in all respect.

Supply, installation, testing & commissioning of Dosing System. Horizontal centrifugal with PP/PVC impeller,
200 lph@6m head. Capacity 0-12 LPH, HDPE tank 500 ltrs.
Magnetic flow meter

Providing & fixing on line full bore type Magnetic flow meter with preamplifier & microprocessor based
electronic flow meter mounted in plumbing plant room electrical control panel with the following features.
Monitoring the total flow, Flow rate, etc. Including electrical wiring from preamplifier to microprocessor based
flow meter.
Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete
with all respect. The signal from read out shall be 4-20 m.amps to be received as BAS.

a) Suitable for flow rate of sewage feed pump to SBR tank


ELECTRICAL INSTALLATION FOR STP

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre
fully compartmentalised fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top
as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per
specifications with 2 coats of redoxide primer and final approved shade of powder coated paint. 2 Nos. earthing
terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in
case of large panels. Approval shall be taken for each panel before fabrication. Quoted rates shall be inclusive
of cables(in accordance to specification) with earthing from panel to each motor / equipment.

a. All MCCBs/MCBs shall be of 15KA breaking capacity and suitable for motor duty
application.
b. All motor starters shall be provided with Automatic level controller
c. DOL starters shall be used for motors below 10 HP and Star-Delta Starters for other
motors .
d. Provision shall be made for providing potential free contacts to all pumps starters
MCC for all STP equipments/pumps as described in sub head II

Water Treatment Plant

Contractor must include all items that are necessary and essential to provide a complete working plant to the
satisfaction of consultant/engineer in charge. No extra payabe later. Any deficiency/improvement in this offer
(specs/boq) must be brought to the knowledge of the consultant/engineer in charge, now-before offering the boq
given hereafter is only for the purpose assessing the overall costing of the project and will be used for arriving at
the payment schedule to the contractor for actual and approved work done. All Quoted Equipments and Pumps are
inclusive of all taxes.Design, Engineering, and providing all equipment /machinary at site, installation and
commissioning of equipments/ electricals/ piping exclusive of all types of taxes and duties.

Raw Water Treatment Plant


Supply, fitting, fixing of water treatment plant including below items/components
Raw Water Feed Pump :

Supplying, installing, testing & commissioning of filter feed water pumps CI Body, SS shaft, bronze Impeller
with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery
line. Isolation valve, stainer at suction.

System component and specification: vertical multi-stage centrifugal pump complete


with accessories, motor insulation class f (2 duty, 2 standby)
Operation of pump shall be based on level controller proposed to be installed in tank as
per site location. The contractor to ascertain the Head required for pumps as per site conditions and
provide accordingly
Each pump capacity = 41 m3/hr. & Head, H=15-40 m

Control function and control devices : Floatless switch control at raw water tank
- low level alarm
- low level stop raw water feed pumps
- low level start deep well pump
- high level stop deep well pump
- high level alarm

Supplying, installing, testing and commissioning of FRP vessel filter with frontal piping and
associated valves and accessories. Filter shall be suitable for minimum working
pressure of 5kg/cm2 and shall include media, standard fittings like pressure.

Iron Remover Filter (IRF-01 & IRF-02)

System component and specification: pressure sand filter with multiport vavle, automatic
air relief valve ,pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller

Multigrad Pressure Sand Filter (MF-01 & MF-02)

System component and specification: pressure sand filter with multiport vavle, automatic
air relief valve ,pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller

Activated Carbon Filter (ACF-01 & ACF-02)

System component and specification: activated carbon filter with multiport valves,
automatic air relief valve, pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller
Water Softening Plant

Supply, installation, testing & commissioning of water softening plant (FRP) for making up of water for toilet
washing and other purpose comprising of multiport valve with brine ejection and plastic piping complete with
brine tank with fitting & brine fitting, filtering media and complete charge of cation exchange resine.
Automatically operated by plc controller

Each pump capacity, Q = 41 m3/hr. & Head, H=40 m


Working Pressure 3.0 Kg/Cum
Automatically operated by plc controller
Cartige Filter

Cartige Filter (CF-01 & AC-02)

System component and specification: activated carbon filter with multiport valves,
automatic air relief valve, pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller
Chemical Storage Tank (CST- 01)
System component and specification: polyethylene tank with cover, level indicator, drain
connection and accessories for metering pump installation
Volume = 200 Liters
Chlorine Storage Tank (CST- 02)
System component and specification: polyethylene tank with cover, level indicator, drain
connection and accessories for metering pump installation
Volume = 200 Liters

Chemical Feed Pump for CST-01 (CFP - 01)

System component and specification: diaphragm metering pump adjustable stroke type, non- corrosive casing
complete with foot valve, injection check valve and accessories

Each Pump Capacity = 10 L / h & H = 6.5 Bar and V/Ø/Hz: 220/1/50

Automatically operated by flow switches


Chlorine Feed Pump for CST-02
(CFP - 01)

System component and specification: diaphragm metering pump adjustable stroke type, non- corrosive casing
complete with foot valve, injection check valve and accessories

Each Pump Capacity = 10 L / h & H = 6.5 Bar

V/Ø/Hz: 220/1/50
Automatically operated by flow switches
Chemical Mixer for Chemical and Chlorine Storage Tank (MX - 01 & MX - 02)
System component and specification: stainless steel shaft and impeller completed motor
insulation class f
Capacity for 200 Liters HDPE Tank
RPM: 1600
V/Ø/Hz: 220/1/50
Manually Operated
Cold Water Booster Pump Set
Package constant pressure booster pump consists of 2 pumps sized for 50% and 50%
of the total system flow rate, complete with diaphragm pressure tank, regulating valve, control devices and control
panel from manufacturer
(1 set duty, 1 set standby)

Each Pump Capcity: 20 m3/hr. x 4 nos in set Head = 78 m


Diaphragm Tank Volume > 400 L
Control details: floatless sensor control at each water tank
- very low level alarm
- low level stop booster pumps (cwbp-01, 02)
- low level stop soft water feed pumps (sffp-01, 02)
- high level stop raw water feed pumps(rwfp-01,02)
- very high level alarm Booster pump set
- automatic operation by discharge pipe pressure sensor & control system
- remote outputs to bas for on/off/fault status
- lead pump shall be alternated periodically by the control system

Hot Water Feed Pump :

Supplying, installing, testing & commissioning of hot water centrifugal pumps, CI Body, SS shaft, bronze
Impeller with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on
delivery line. Isolation valve, stainer at suction.

System component and specification: vertical multi-stage centrifugal pump complete


with accessories, motor insulation class f (2 duty, 2 standby)
a).Hot water Heating pump = 100 liter/min. & Head, H=5 meter
b). Hot water Circulating pump = 225 liter/min. & Head, H= 11 meter
c). Hot water Heating pump(FS) =80 liter/min. & Head, H=5 meter
b).Hot water Circulating pump(FS) =25 liter/min. & Head, H= 5 meter
DEEP TUBE WELL WITH ALL FITTING AND FIXTURE INCLUDING PUMP
ELECTRICAL CABLE WORKS
Electrical works shall be complete with supply and installation of all cables, conduit,
distribution board etc. as per direction of the Engineer.

PDB DEPOSIT WORK


PDB. Deposit work for Extension of Duel 11K.V. Express Feader line from PDB Sub-
station to Airport Side.
Sub-Total (Building Works)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

Cum 26002.35

Cum 866.75

No 29.00
No 29.00

Sqm 5900.00

Cum 442.50

Cum 7237.50
Cum 6140.10
Cum 3950.00

Ton 6802.80
Sqm 43630.00

Cum 3272.25

Cum 16099.00
Cum 3908.00
Cum 860.00
Cum 1486.00
Cum 2160.00
Cum 1486.00
Cum 250.00
Cum 566.00
Cum 20.00
Cum 120.00
Cum 20.00
Cum 120.00
Cum 30.00
Cum 120.00
Cum 30.00
Cum 240.00
Cum 40.00
Cum 120.00
Cum 40.00
Cum 120.00
cum 95.00

Ton 4081.84

Cum 19239.00
Cum 2335.00
Cum 2555.00

Sqm 1776.00
Sqm 435.00
Sqm 526.00

Sqm 46960.00

Sqm 17319.00

Sqm 120675.00

Sqm 96979.00

Sqm 5829.00
Sqm 8247.00

kg 12485000.00

kg 538837.00

kg 431836.00

kg 1650348.00

Sqm 48080.00

Sqm 48080.00

Sqm 48080.00

Sqm 35840.00

Sqm 48080.00
Sqm 23105.00

Sqm 3780.00

Sqm 6997.00

Sqm 2472.00

Sqm 4608.00

Sqm 654.00

Cum 1546.00

Sqm 13723.00
Sqm 26500.00

Sqm 6255.00

Sqm 7760.00

Sqm 3420.00

Sqm 26570.00

Sqm 114200.00

Sqm 14645.00

Sqm 1372.00

Sqm 538.00

Sqm 701.00

Sqm 75.00
Sqm 344.00

Sqm 521.00

Sqm 19320.00

Sqm 3967.00

Sqm 481.00

Sqm 1897.00

Sqm 392.00

Rm 2091.00

Sqm 483.00

Nos. 110.00
Rm 9845.00

Sqm 1070.00

Sqm 1964.00

Sqm 3150.00

Set 800.00

Set 80.00

No 350.00

Set 24.00

Set 45.00

Set 600.00

Set 1.00

No. 25.00

No. 50.00

No. 95.00

No. 25.00

No. 50.00

No. 92.00

No. 188.00
No. 75.00

No. 150.00

M 60,750.00
M 1,870.00
M 5,201.00
M 2,640.00
M 2,655.00
M 4,280.00
M 2,335.00
M 2,160.00
M 2,890.00
M 840.00
M 840.00

Nos. 3,045.00
Nos. 5,550.00
Nos. 1,470.00
Nos. 1,910.00

Nos. 44.00
Nos. 19.00

Nos. 2.00

Nos. 106.00
Nos. 106.00
Nos. 14.00
Nos. 7.00

M 330.00

Nos. 9.00
Nos. 7.00

Nos. 45.00

Job 4.00

Nos. 1.00

Nos. 1.00

Nos. 1.00
Lot 1.00

No 12.00

No 186.00

No 82.00

No 72.00

No 70.00

No 62.00

No 222.00

No 10.00
No 279.00

No 260.00

Sqm 238.00

No 175.00

No 175.00

No 246.00

No 255.00
No 40.00

No 750.00

No 433.00
No 22.00
No 49.00

No 433.00
No 58.00
Rft 2,500.00
Rft 340.00
Rft 2,450.00
Rft 5,805.00
Rft 740.00
Rft 11,000.00
Rft 4,620.00
Rft 1,210.00
Rft 120.00

Rft 11,900.00
Rft 4,250.00
Rft 460.00
Rft 280.00
Rft 390.00
Rft 610.00
Rft 515.00
Rft 175.00

No 117.00
No 39.00
No 31.00
No 34.00
No 36.00
No 18.00
No 10.00
No 10.00
No 34.00
No 53.00
No 45.00
No 23.00

No 9.00

No 16.00

No 430.00
No 22.00

No 11.00

No 22.00

No 20.00

No 20.00
No 20.00

No 20.00

No 20.00

No 300
No 240
No 150
No 720
No 40
No 430
No 360
No 325

No 4080

No 70

No 1030
No 1032
No 310
No 310
No 80
No 90
No 2852
No 35

No 35

No 270
No 120
No 60
No 160
No 92
No 120
No 60
no 40
No 60
No 30

No 125
No 90
No 50

No 530
No 515
No 517

No 727
No 425
No 450
No 165

No 165

No 260
No 220

No 655
No 340
No 340
No 40

No 25
No 125
No 250

No 50

No 266

No 6124

No 1775

No 1063

No 1244

No 12
No 71
No 431

No 337

No 11057

NOS 2

NOS 2

M 7200

NOS 2

NOS 7
NOS 5

NOS 3

NOS 2

NOS 1
NOS 1

NOS 1

NOS 1

2
set 2

m 1600

Job 3

No 3

No 2
set 1

set 4
set 2

set 2

no 1
no 2

no 1

no 1

no 5
E

no 10

E
no 4

no 4
E

no 26

E
no 135

no 30
no 50
no 10
no 45
no 30
no 25

m 150
m 100
m 115
m 150
m 1050
m 2020
m 500
m 5000
m 4260
m 305
m 4,000
m 2900
m 3250
m 1,760

m 2,000
m 1,600
m 1,200
m 1,000
m 1,900
m 2,000
m 1,800
m 600

No 2

No 2

No 3
No 6
m 4,030
No 16

No 1

No 16

No 622

No 3622

No 189
No 158

No 675

No 206

No 145

No 298

M 124500
M 77800

Lot 1
Set 2

Set 2
Set 2

Set 2

Set 2

Set 2

Lot 1

Lot 1

Job 1

Job 1

Set 1
Set 1

Set 1

Set 1

Set 1

Set 2

Set 1

Set 1

Set 1

No. 1

Each 2
No 1

Job 1

Set 2
Set 2

Set 2

Set 2

Set 2

Set 2
Nos. 1

Nos. 2

Nos. 2

Nos. 2

Set 2
Job 1

Job 1

LS
Item No.

4
4.1: Construction of Apron, Taxiway & Shoulder

4.1.1

4.1.2

4.1.3
4.1.4

4.1.5

4.1.6

4.1.7

4.1.8

4.1.9

4.1.10

4.1.11

4.1.12

4.1.13

4.2: Construction of Road, Carpark & Foothpath

4.2.1
4.2.2

4.2.3
4.2.4

4.2.5

4.2.6

4.2.7

4.2.8

4.3: Construction of Drainage System

4.3.1

4.3.2

4.3.3

4.3.4

4.3.5

4.3.6

4.3.7
4.3.8

4.3.9

4.3.8

4.4: Water Supply and Sewerage System

4.4.1

4.4.1

4.4.2
4.4.3

4.4.4

4.4.5

4.4.6

4.4.7

4.4.8

4.4.9
4.4.10

4..4.11

4.4.12
4.4.13

4.4.14

4.4.15

4.4.16

4.4.17
4.4.17

4.4.18

4.4.19

4.4.20

4.4.21

4.4.21
4.4.21

4.5
4.5.1

4.5.1.1
4.5.1.2
4.5.1.3
4.5.1.4
4.5.1.5

4.5.2

4.5.3

4.5.3.1

4.5.3.2
4.5.3.3

4.5.3.4

4.5.3.5

4.5.4

4.5.4.1

4.5.4.2

4.5.4.3

4.5.4.4

4.5.4.5

4.5.4.6

4.5.5
4.5.6

4.5.7
Description of Item

Civil Works
Construction of Apron, Taxiway & Shoulder
Construction of crushed aggregate sub-base course in/cl transport of materials from approved quarry,
crushing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-154)
Construction of crushed aggregate base course in/cl transport of materials from approved quarry, crushing,
laying, compaction etc. as per design, drawing, specification of
relavant chapter and accepted by the Engineer. (FAA; P-209)
Supply and provide Bituminous material Prime coat. (FAA; P-602)
Supply and provide Bituminous material Tack coat (FAA; P-603)
Construction of asphalt concrete base course in/cl transport of aggregates, import of bitumen, mixing,
laying, compaction etc. as per design, drawing, specification of relavant
chapter and accepted by the Engineer. (FAA; P-403)
Construction of asphalt concrete surface/wearing course in/cl transport of aggregates, import of bitumen,
mixing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-401)

Construction of Lean Mix Concrete Composed of aggregates, Portland cement , water and approved additives on
a prepared sub-grade in conformity with the lines, grades in/c. using concrete pump machine as per design,
drawing, specification of relavant chapter and accepted by the Engineer. (FAA; P-306)

Construction of pavement quality concrete (PQC) slab composed of aggregates, Portland cement, water and
approved additive on L.M.C base in conformity with the lines, grades in/c. using concrete pump machine as
per design, drawing, specification of relavant chapter and accepted by the Engineer. (FAA; P-501)

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
or any where below cement concrete complete in all respect and
accepted by Engineer-in-charge.
S.F&F of dowel bar cage with 1/2" dia (60 grade) M.S rod to proper size including
painting with anticorrosive paint etc. as per design, drawing, specification of relavant chapter and accepted
by the Engineer.
Supplying fitting fixing 40 mm dia 510 mm long (Foreign made) Fusteel or equivalent brand Epoxy coated M.S
plain round dowel bar as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supply and laying 2 mm thick Geo-textile of approved quality and origin/manufacturer as per manufacturer’s
instructions approved and accepted by the Engineer. Before commencing laying of Geo-textile, the
Contractor must submit the method statement for carrying out this work including sample with evidence of
origin and compliance certificate from independent testing laboratory for approval.

Joint filling with joint sealing compound as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Construction of Road, Carpark & Foothpath
Construction of crushed aggregate sub-base course in/cl transport of materials from approved quarry,
crushing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-154)
Construction of crushed aggregate base course in/cl transport of materials from approved quarry, crushing,
laying, compaction etc. as per design, drawing, specification of
relavant chapter and accepted by the Engineer. (FAA; P-209)
Supply and provide Bituminous material Prime coat. (FAA; P-602)
Supply and provide Bituminous material Tack coat (FAA; P-603)
Construction of asphalt concrete base course in/cl transport of aggregates, import of bitumen, mixing,
laying, compaction etc. as per design, drawing, specification of relavant
chapter and accepted by the Engineer. (FAA; P-403)
Construction of asphalt concrete surface/wearing course in/cl transport of aggregates,
import of bitumen, mixing, laying, compaction etc. as per design, drawing, specification of relavant chapter and
accepted by the Engineer. (FAA; P-401)
Supplying and placing of 60 mm thick coloured uni-block for paving foot-path, major walk way, car
porch having compressive strength of 49 N/mm2 on compacted sand bed of 50 mm on stabilized soil base, and
filling all interstices with sand, cleaning etc. as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying, carrying, placing, providing of 100 mm thick concrete Kerb stone as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
Construction of Drainage System
Construction of crushed aggregate sub-base course in/cl. transport of materials from approved quarry,
crushing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-154)
Construction of aggregate base course in/cl transport of materials from approved quarry, crushing, laying,
compaction etc. as per design, drawing, specification of relavant chapter
and accepted by the Engineer. (FAA; P-209)

Construction of Lean Concrete Composed of aggregates, Portland cement, water and approved additives
on a prepared sub-grade in conformity with the lines, grades in/c. using concrete pump machine,
formwork etc. as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Reinforced cement concrete (Class 32) works using steel shutter with minimum cement content relates to mix
design having minimum f'cr = 40 Mpa, and satisfying a specified compressive strength f’c = 32 Mpa including
formwork etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication).

Supplying, carrying and fabrication of Grade 60 ribbed or deformed bar complying BDS ISO 6935-2:2006,
produced and marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 414
MPa but fy not exceeding 450 MPa and whatever is the yield strength within allowable limit as per BNBC/
ACI 318, the ratio of ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum
elongation after fracture and minimum total elongation at maximum force is 16% and 8% respectively. All
complete as per detailed description of the relevant specification and direction of the Engineer in charge.

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
or any where below cement concrete complete in all respect and
accepted by Engineer-in-charge.

Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:3) with fresh cement to concrete surface and finishing
the corners and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost of
water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
Engineer-in-charge. (Cement: CEM-II/A-M)
Surface Drain with CC (1:1.5:3) with ussed stone chips Construction of R.C.C Surface drain size (2m +1.61m X
o.98) earth excavation in trenches 150 mm sand filling single layer polythene laying & single layer Brick flat
soling and 0.30 m depth 1.61 m wide Bottom slab and 68 m hight 0.23m Thick side wall R.C.C (1:1.5:3)
with 1.5% Reinforcement with steel shutter and 150 mm dia P.V.C pipe 6.0 m lond 6.0 m interval as requipment
with 6 mm thick NCF Cement sand (FM.1.2) Plaster etc all complete approve and accepted drawing by the
Engineer in Charge.

Supply fitting fixing of Reinforced concrete pipe, perforted Pipe & PVC Pipe as per
relevent speciication , drawings and accepted by the Engineer.
a) Reinforced Concrete pipe- D1200 mm
b) Reinforced Concrete pipe- D1500 mm
c) Reinforced Concrete pipe- D2000 mm
d) Reinforced Concrete pipe- D 600 mm
e) PVC pipe- D 200mm
f) Perforated pipe- D150mm
g) PVC pipe- D 150mm
Lining of drain with one layer brick flat soling with first class/picked jhama bricks, filling the joints with cement
sand mortar including preparation of bed, compaction, leveling
etc. complete and accepted by the Engineer.
Water Supply and Sewerage System

Supplying, fitting and fixing different diameter best quality heavy type uPVC pipes (RFL/National/Hatim
or equivalent) and will be completed all uPVC fittings like tees, Y, cross-tee, reducer-Y, elbows, bends, Offset,
sockets, reducers, test opner or door socket, clean out cap and vent cowl with solvent cement clamping to
wall or hanging under ceiling or concealed properly at an interval of not more than 1200mm as in
drawing, groove cutting in brick work, R.C.C floor, making holes and mending good the damages including
supply and carriage of all materials, labour, tools, incidentals etc. complete as per drawing and direction of the
Consultant/PD. Product shall be as per BSTI approved manufacture standard or ASTM, BS/ISO/IS standard.

Supplying and laying uPVC underground pipe including fitting, fixing etc. all complete as per approved design,
drawing, relevant specification and accepted by the Engineer- in-
charge.
a). 150 mm dia, 6.2 mm thick
b). 200 mm dia, 7.7 mm thick
c). 250 mm dia, 9.6 mm thick
d). 300 mm dia, 12.1 mm thick
e). 350 mm dia, 12.1 mm thick
f). 400 mm dia, 12.1 mm thick
Supplying and laying 80 Schedule Pressure Pipe: all complete approved design, drawing,
relevent specification and accepted by the Engineer- in- charge.
a). 50 mm dia, wall thickness 3.9 mm to 4.5 mm
b). 65 mm dia, wall thickness 5.8 mm
c). 75 mm dia,wall thickness 6.8 mm
d). 80 mm dia,wall thickness 6.8 mm
e). 100 mm dia,wall thickness 6.8 mm
f). 150 mm dia,wall thickness 6.8 mm
Construction of masonry inspection pits inside measurement are given below, with 150 mm thick brick work in
cement mortar (1:4) with 100 mm thick R.C.C. top slab (1:2:4) with 1% reinforcement, (600mmx600mm) or
600mm dia water sealed R.C.C. Manholecover in/c. necessary earth work, side filling and one brick
flat soling, 75mm thick (1:3:6) base concrete for making invert channel and 12 mm thick (1:2) cement
plaster with neat finishing etc. all complete up to the given depth as per drawing, relevent specification
and direction of the Engineer-in-charge.

a). (900 x900 mm)


b) (1350 x 1350mm)
c) (1800 x1800)
b). (1200 x1200 mm)

Execution of boring through different strata for all-through 650x450x400 dia vertical
bore hole up to design depth interval. This is also includes sinking with drawing casting pipe and complete as per
specification & direction of Engineer.
a) From depth 000m- 31m
b) From depth 32-62m
c) From depth 62-92m
d) From depth 93-123m
e) From depth 124-163m
Supplying and Installation of 300 mm Dia MS Housing Pipe wall thickness 6 mm as per
specification & direction of Engineer.
Supplying and Installation of 150 mm Dia SS Filter, Slot opening 30/35 as per
specification & direction of Engineer.
Supplying and Installation of the following fittings and fixtures as per specification &
direction of Engineer.
a) 150 mm blank pipe wall thickness 4 mm
b) 200x150mm Dia MS Reducer
c) 150mm Dia bail Plug cop
d) 150mm Shocket
e) Tie rod 500mm -100mm Long (37mm dia MS rod)
f) Centralizer 150mm Dia made by 12.5 mm dia plain rod
g) Welding rod SS+MS

Supplying and Making pea gravel pack around tha tube well fixtures and bore hole with supply of approved
including sieving washing etc. complete as per standerd practice and extra amount required for extra depth bellow
the tube well fixtures as per specification & direction of Engineer.

Development by air compressor as per specification & direction of Engineer.


Development by submersible pump as per specification & direction of Engineer.
Supplying, Fitting and Fixing of Housing Pipe filter etc. as per specification & direction
of Engineer.
Supply of Submersible Pump Motor set Technical specification for submersible pump
motor set ( 85 HP)
Item :- Bore well Pump Motor Type Brand :- KSB
Pump type :- Submersible
Pump motor model :- BPN 374/4+NB 623 Head :- 120-130 M
Discharge capacity :- (150-180) m3/Hr.
Motor type :- Submersible, Water filled, Water lubricated & Rewind able. Impeller Material :- Bronze
Shaft protection Sleeve :- Bronze Bearing Bush :- Bronze
Pump Shaft :- Cr. Steel
Pump Stage Bowl :- Cast Iron.

Motor rating :- (75HP-85HP)/63KW. Current (Approx) :- (100-126 Amps). Speed :- 2850-3000 rpm.
Starting Method : - Star-Delta.
Power connection :- 3 Ph, 50 Hz, and 400 V (± 10%)
Cable size :- 2×3 Core, 25mm2 (03 double meter cable included with motor) Pump Delivery :- 6" dia flanged
type with internal NRV.
Pump motor outer dia :- 206 mm (Approximate) Pump+ Motor total length :- 2412 mm (Approximate). Pump
motor overall efficiency :- More than 75% Standardization :- ISO 9001.
Make/Origin :- KSB Pumps Ltd, Germany, UK, France or equivalent.

Supply & installation of sheet steel clad (16 SWG) dust vermin proof free standing floor mounting type 415 v,
50 Hz indoor type LT panel with necessary painting having comprising components 62 HP Star-Delta
auto Control Panel with all necessary protections Incoming circuit breaker of sufficient capacity,
Ammeter with ASS Volt meter with VSS, C/T of power current ratio & burden, Main Contactors,
Auxiliary Contactors, Indicating light for on, off, Trip indicator, O/L relay, Pneumatic timer, Pump guard for phase
failure /Dry run protection reverse phase sequence protection, Cable ties & lugs, Connectors etc.

Major Components:-
Bhartiya Cutler-Hammer, Telemechanique France, Siemens or equivalent etc.
Providing & fixing additional marine cable for submersible Pump Motor Set manufactured according
to DIN/NEMA/IEC/BS/VDE/JIS & ISO 9001 standard (Foreign
made) & as per sample accepted/approved by the Engineer.
i) 3C – 25 sq mm

Providing & fixing of following dia 3.78 meter (10'-0) long column pipe to be connected with submersible Pump
Motor Set made of steel column pipe (API-5L, grade-B) with all standard accessories including special flange
at both ends including anticorrosive painting etc. as per sample accepted/approved by the Engineer.

i) 200 mm (8") dia

Supply, installation, testing & commissioning of following 425B, 3-phase 50Hz, electronically
controlled, automatic voltage stabilizer/regulator locally assembled in metallic painted cabinet suitable for
input voltage range 300-460V, Output steeples continuous voltage 400V ± 3% correction speed 20V/Sec
(minimum) complete with phase failure and spike & surge-fluctuation voltage protection, auto shut off at high
& low voltage with auto reset system, overload & instantaneous short circuit protection by MCCB & relay,
transient suppression circuit, ON-OFF-TRIP indicators, voltmeter.

a) 250 KVA AVR


Assembled by AEG / MICRO / NAVANA / RAHIMAFROOZ or equivalent approved
by the Engineer-in-Charge.
Supply & installation
i) 150 mm dia gate valve-01 No.
ii) MS bass plate with lifting hook-01 No
iii) 150 mm dia rubber flexible-01 No.
iv) Pressure Gauge-01 No.
v) Mounting Clamp-01 No.
vi) 150 mm Flow meter-01 No.
vii) Short piece, Nipple, Nut-bolt, gasket, etc. -01 Lot
viii) Floor mat- 4 nos
Cost of installation & Commissioning of (75-85 HP) submersible pump, Motor.

Providing & laying of the following PVC insulated & sheathed cable (NYY)/ coloured ECC wire (BYA)
connecting at both ends, through PVC pipe & accessories in the following manner. All electrical contacts
shall be of brass/copper connected through connector or soldering ( no twisting shall be allowed) and cables
shall be manufactured and tested according to relevant IEC/BDS/BS/VDE standards and as per detailed
specification mentioned in Annexure-A. The work shall be carried out as per
direction/approval/acceptance of the Engineer .

In pucca floor through PVC pipe by cutting trench of necessary size and mending the
damages good by brick soling, 75 mm (1:2:4) CC work with neat cement finishing etc,
Cables manufactured by BBS/MEP/Poly Super sign/Fecto Industries
(Citizen)/Evana/Khawaja
(777 Energy Cable) or equivalent accepted/approved by the Engineer.
1C-4 × 120 sq mm (NYY/2XY) with 70 sq. mm (BYA) ECC wire through PVC pipe of
minimum inner dia 75 mm having wall thickness of 3 mm
In Pucca floor.

Earthling the electrical installation with 40mm (1.5") dia G.I pipe (Earth electrode) having 6.35mm dia
hole across the pipe at 305mm interval securedly bonded by soldering with 2 nos of No2 SWG HDBC earth
leads with its protection by 20 mm (3/4") dia G.I pipe up-to plinth level run at a depth of 609.6 mm ( 2ft) below
G.L up to main board to be earthed including necessary connecting copper sockets, bolts, nuts, etc.
complete for maintaining earth resistance within 1 ohm.

a) Depth of bottom of main electrode at 37338 mm ( 122.5 ft) from GL & length of per
set electrode 36576 mm ( 120 ft)

b) Construction of Earthling inspection pit inside measurement 600 mm × 600 mm with 250 mm thick brick in
cement morter (1:4) with 100 mm thick RCC topo slab (1:2:4) with 1% re-inforcement 450 mm dia water
sealed CI man-hole cover with locking arrangement including necessary earth works, site filling and one brick
flat soling 75 mm thick (1:3:6) base concrete for making inlet channel & 12mm thick (1:2) cement plaster with
neat finishing etc. all complete up to a depth of 75 meter.

c) Providing & fixing 25.4 mm (1") dia 457 mm (1.5 ft) long solid copper rod with sharp top end for arresting
lightning securely bonded with 6.6 mm thick 150 mm × 150 mm Copper baser plate to be recessed in wall
complete with nuts, bolts, C.C work etc.
d) Providing & drawing No-2 HDBC wire through 12.7 mm ( ½ ") dia G.I pipe including
fitting, fixing the G.I pipe in wall or column complete as required.

Providing & fixing of 18 SWG metal clad 500 volt 3 phase two way change-over switch of following capacity
complete with moving & fixed copper contacts, copper buses, brass nuts and bolts, 3mm thick ebonite sheet
separators insulators, operating handle etc. complete including necessary hammer painting on enclosure.

400 Amps. rating.


Supplying of 415V, 3 phase, 50Hz following capacity Control Circuit Breaker feeder unit as per following
specification with thermal over current & instantaneous electromagnetic short-circuit release
manufactured and tested as per NEMA/IEC/VDE/BS/JIS standards (adjustable type above 100A
rating) for sub-station
L.T panel.
Rated operating voltage: 220-690 V,
Rated insulation voltage 690 volt
Rated impulse withstand voltage 6 KV
Utilization Category: A or B
400A (35KA) TPMCCB
AEG / Dorman Smith /MEM /Siemens /Eaton/Schneider or equivalent
accepted/approved by the Engineer.

Miscellaneous Works
Marking

Painting different marking of Apron by spray machine with best quality rubberized synthetic high built
approved quality and brand runway marking paint mixed with best quality T-4 Thinner 20% of Paint, cleaning
and washing the surface with coir and wire brush & finishing the edges properly etc. all complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.

Yellow
Red
Blue
Black
White
Landscapping Work as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Road Signs

Stack Type Sign Board: Providing Supplying & fixing single sided Sign board of 4mm ACP with face fully
covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols
accordingly, fixed with the help of Very High Bond tape of 24mm wide and 2.3mm thick. The board shall
have a two leg support with necessary holes, nuts bolts & caps. The boards shall be fixed on two nos.
RCC foundations complete with all relevant specs confirming to detail drawing enclosed. Material should
be in compliance with Code of practise for Road signs according to BRTA (Detail as per enclosed
drawing). All complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Gantry Type over Head Sign: Fabrication Supplying & Erecting of Over Head Gantry structure made of steel
work in built up tubular (round, suare or rectangular hollow tubes etc. trusses etc.) including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer, welding and bolted with special
shaped washers etc. including necessary foundation work complete with centering/ shuttering etc. as per
approved drawing and to the satisfaction of engineer in charge. The whole gantry shall be painted with 2 Coat of
Epoxy paint of desired colour. Messages and graphics shall be plotter cut with overlay sheeting or HIGH
INTENSITY PRISMATIC GRADE Type IV fixed with Very High Bond tape of 24mm wide and 2.3mm thick and
rivets, fixed on to structure with the help of suitable expansion fastners. Material should be in compliance with
Code of practise for Road signs according to BRTA.(Detail as per enclosed drawing). All complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.
Map Type Sign Board: Providing Supplying & fixing single sided Sign board of 4mm ACP with face fully
covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols
accordingly, fixed with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board shall
have a two leg support with necessary holes, nuts bolts & caps. The boards shall be fixed on two nos.
RCC foundations with CC 1:2:4 laid with the help of shuttering complete with all relevant specs
confirming to detail drawing. Material should be in compliance with Code of practise for Road signs
according to BRTA. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer.

Flag Type Sign Board: Providing Supplying & fixing double sided cantilever Sign board of 4mm ACP
with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and
symbols accordingly, fixed with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board
shall have a single leg support with necessary holes, nuts bolts & caps. The boards shall be fixed on RCC
foundations complete with all relevant specs confirming to detail drawing . Material should be in compliance with
Code of practise for Road signs according to BRTA. all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Miscelleneous Sign: Making both side support of the sign board by 75 to 100mm MS pipe and making framing
with pipe, angle or flat bar as required face fully covered by RETRO REFLECTIVE MICRO PRISMATIC
Type IV Sheeting, and messages and symbols accordingly, fixed with the help of Very High Bond tape of
24mm wide and 2.3mm thick, compliance with Code of practise for Road signs according to BRTA. all complete
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Traffic Signs
Over head sign
Making of Sign board with steel member as per design and printed on 12 BWG sheet all complete as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Making both side support of the sign board by 200mm MS pipe and making a frame with 100, 75, 50 & 25mm
dia MS pipe with required bracing all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
Way wide sign
Making of Sign board with steel member as per design and printed on 12 BWG sheet all complete as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Making both side support of the sign board by 75 to 100mm MS pipe and making
framing with pipe, angle or flat bar as required all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Post type sign
Making of Sign board with steel member as per design and printed on 12 BWG sheet all complete as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Making a sign post of 75 to 100mm dia MS pipe all complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Toll Booth Rumble strips all complete as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
Providing painting at the top of the road surface as road marking in two coats with approved best
quality and colour of synthetic paint from authorized local agent of the manufacturer in a sealed container
having high water resistance, high bondability & flexibility, using specific brand thinner applied by
machine or others over a coat of priming, providing elapsing time for drying including surface cleaning from
dust, oil or dirt, smoothening, finishing necessary tools etc. all complete & approved and accepted by the
Engineer.

Exposed brick works (for exterior wall without outside plaster) with special quality sorted out first class
bricks, very carefully laid in cement sand (F.M. 1.2) mortar (1:4) in superstructure with uniform width and
depth of joints, true to vertical and horizontal lines including raking out joints, scaffolding, soaking the bricks
at least for 24 hours before use, washing and screening of sand, curing at least for 7 days and high class flush
pointing with cement sand (F.M. 1.2) mortar (1:1) including cost of water, electricity and other charges etc all
complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Sub-Total (Civil Works)


Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

Cum 28,650.00

Cum 53,580.00

Sqm 110500.00
Sqm 534000.00

Cum 23,010.00

Cum 10,190.00

Cum 17,800.00

Cum 44,100.00

Sqm 187350

Rm 56880.00

Each 64100.00

Sqm 190000.00

Rm 29040.00

Cum 14,700.00
Cum 13,950.00

Sqm 105000.00
Sqm 150000.00

Cum 8,650.00

Cum 5,550.00

Sqm 15000.00

Sqm 5500

Cum 2603.95

Cum 2603.95

Cum 959.00

Cum 10563.00

Ton 2350.99

Sqm 15177.00

Sqm 56280.00
Rm 2452.00

Rm 10.00
Rm 79.00
Rm 15.00
Rm 175.00
Rm 200.00
Rm 3276.00
Rm 1909.00

Sqm 8000.00

No 30.00 800.00 24,000.00

Rft 500.00
Rft 3900.00
Rft 4550.00
Rft 4610.00
Rft 1200.00
Rft 150.00

Rft 6911.00
Rft 200.00
Rft 200.00
Rft 6912.00
Rft 200.00
Rft 15000.00
No 345.00
No 10.00
No 1.00
No 3.00

Rm 124.00
Rm 124.00
Rm 120.00
Rm 120.00
Rm 156.00

Rm 560.00

Rm 240.00

Rm 240.00

Rm 24.00
Nos 4.00
Nos 4.00
Nos 72.00
Nos 84.00
Nos 28.00
Job 4.00

Rm 732.00

Job 4.00
Job 4.00

Rm 824.00

Set 4.00
Set 4.00

M 1000.00

No 112.00

No 4.00
lot 4.00
Job 4.00

M 120.00

Set 16.00

Set 16.00

Set 16.00

M 160.00

Job 2.00
No 4.00

sq.m 2616.00
sq.m 233.00
sq.m 181.00
sq.m 15.00
sq.m 447.00

Job 1.00

sq.m 42.00

120.00
sq.m 5.00

sq.m 4.00

sqm 4.50

sqm 6.00

Job 3.00

sqm 3.00

Job 2.00

sqm 8.00

Job 5.00

Job 8.00
Sqm 3150.00

Cum 176.00
Item No.

5
5.1

5.1.1

5.1.2
5.1.3

5.1.4

5.1.5

5.1.6
5.1.7

5.1.8

5.1.9

5.1.10
5.1.11

5.1.12

5.1.13

5.1.14

5.1.15

5.1.16

5.1.17

5.1.18
5.1.18

5.1.19

5.1.20

5.1.21

5.1.22

5.1.23

5.1.24

5.1.25

5.1.26

5.1.27
5.1.27

5.1.28

5.1.29

5.1.30

5.1.31

5.1.32

5.1.33
5.1.34

5.1.35

5.1.36
5.1.37
5.1.38
5.1.39
5.1.40
5.1.41
5.1.42
5.1.43
5.1.44
5.1.45
5.1.46
5.1.47
5.1.48
5.1.49
5.1.50
5.1.51
5.1.52

5.1.53

5.1.54
5.1.55

5.2
5.2.1
5.2.1.1
5.2.2

5.2.2.1
5.2.3

5.2.4

5.2.4.1

5.2.4.2

5.2.5
5.2.5.1
5.2.6

5.2.6.1

5.2.6.2

5.2.6.3

5.2.6.4

5.2.6.5

5.2.6.6

5.2.6.7
5.2.6.8

5.2.6.9

5.2.6.10

5.2.6.11

5.2.6.12

5.2.6.13

5.2.6.14

5.2.6.15
5.2.6.16

5.2.6.17

5.2.6.18

5.2.6.19

5.2.6.20

5.2.7

5.2.7.1
5.2.7.2

5.2.7.3

5.2.7.4

5.2.8

5.2.8.1
5.2.9

5.2.9.1
5.2.9.1.1

5.2.9.1.2

5.2.9.1.3

5.2.9.1.4

5.2.9.1.5

5.2.9.1.6
5.2.9.1.7

5.2.9.1.8

5.2.9.1.9

5.2.9.1.10

5.2.9.1.11

5.2.9.1.12

5.2.9.1.13

5.2.9.1.14

5.2.9.1.15

5.2.9.1.16

5.2.9.1.17

5.2.9.1.18

5.2.9.1.19

5.2.9.1.20

5.2.9.1.21

5.2.9.1.22

5.2.9.1.23

5.2.9.124

5.2.9.1.25

5.2.9.1.26

5.2.9.1.27

5.2.9.1.28

5.2.9.1.29

5.2.9.1.30

5.2.9.2
5.2.9.2.1
5.2.9.2.2

5.2.9.2.3

5.2.9.2.4

5.2.9.2.5

5.2.9.2.6

5.2.9.3
5.2.9.3.1

5.2.9.3.2

5.2.9.3.3

5.2.9.3.4

5.2.9.3.5

5.2.9.3.6

5.2.9.3.7

5.2.9.3.8

5.2.9.3.9

5.2.9.3.10

5.2.9.3.11

5.2.10

5.2.10.1

5.2.10.2

5.2.10.3

5.2.10.4
5.2.10.5

5.2.10.6

5.2.10.7

5.2.10.8

5.2.10.9

5.2.10.10

5.2.10.11

5.2.10.12

5.2.10.13

5.2.10.14

5.2.10.15

5.2.10.16

5.2.10.17

5.2.10.18

5.2.10.19

5.2.10.20

5.2.10.21
5.2.10.22

5.2.11

5.2.11.1

5.2.11.2

5.2.11.3

5.2.11.4

5.2.11.5

5.2.12

5.2.12.1

5.2.12.1.1
5.2.12.1.2
5.2.12.1.3
5.2.12.1.4
5.2.12.1.5
5.2.12.1.6
5.2.12.1.7
5.2.12.1.8
5.2.12.1.9
5.2.12.1.10
5.2.12.2

5.2.12.2.1
5.2.12.2.2
5.2.12.2.3
5.2.12.2.4
5.2.12.2.5
5.2.12.2.6
5.2.12.2.7
5.2.12.2.8
5.2.12.3
5.2.12.3.1
5.2.12.3.2
5.2.12.4
5.2.15.1
5.2.15.2
5.2.12.5
5.2.12.5.1
5.2.12.5.2
5.2.12.5.3
5.2.12.5.4
5.2.12.5.5
5.2.12.5.6
5.2.12.5.7
5.2.12.5.8
5.2.12.6
5.2.12.6.1
5.2.12.6.2
5.2.12.7
5.2.12.7.1
5.2.12.7.2
5.2.12.7.3
5.2.12.7.4
5.2.12.7.5
5.2.12.8
5.2.12.8.1
5.2.12.8.2
5.2.12.8.3
5.2.12.8.4
5.2.12.8.5
5.2.12.8.6
5.2.12.8.7
5.2.12.9
5.2.12.9.1
5.2.12.9.2
5.2.12.10
5.2.12.10.1
5.2.12.10.2
5.2.12.10.3
5.2.12.10.4
5.2.12.10.5
5.2.12.11
5.2.12.11.1
5.2.12.12
5.2.12.12.1
5.2.12.12.2
5.2.12.12.3
5.2.12.12.4
5.2.13

5.2.13.1
5.2.14
5.2.14.1
5.2.14.2
5.2.14.3
5.2.15

5.2.16

5.2.16.1
5.2.16.2
5.2.17

5.2.18

5.2.18.1
5.2.18.1.1
5.2.18.1.2
5.2.18.2
5.2.18.2.1
5.2.18.2.2
5.2.18.2.3
5.2.18.2.4
5.2.18.2.5
5.2.18.2.6
5.2.18.2.7
5.2.18.3

5.2.18.3.1
5.2.18.3.2
5.2.18.3.3
5.2.18.3.4
5.2.18.3.4
5.2.18.3.5
5.2.18.3.6
5.2.18.3.7
5.2.18.3.8
5.2.18.3.9
5.2.18.3.10
5.2.18.3.11
5.2.18.4

5.2.18.4.1
5.2.18.4.2
5.2.18.4.3
5.2.18.4.4
5.2.18.4.5
5.2.18.4.6
5.2.18.4.7
5.2.18.4.8
5.2.18.4.9
5.2.18.4.10
5.2.18.4.11
5.2.18.4.12
5.2.18.4.13
5.2.18.4.14
5.2.18.4.14
5.2.18

5.2.18.1
5.2.18.2
5.2.18.3
5.2.19

5.2.20

5.2.21

5.2.22

5.2.22.1
5.2.24

5.2.25
5.2.25.1
5.2.25.2
5.2.25.3
5.2.25.4
5.2.25.5
5.2.26

5.2.26.1
5.2.26.2
5.2.26.3
5.2.26.4
5.2.26.5
5.2.26.6
5.2.26.7
5.2.26.8
5.2.26.8
5.2.26.9
5.2.26.10
5.2.26.11
5.2.26.12
5.2.26.13
5.2.26.14
5.2.26.15
5.2.26.16
5.2.27

5.2.27.1
5.2.27.2
5.2.27.3
5.2.27.4
5.2.27.5
5.2.27.6
5.2.27.7
5.2.27.8
5.2.28
5.2.29
5.2.30
5.2.31

5.2.31.1
5.2.31.2
5.2.31.3
5.2.31.4
5.2.31.5
5.2.32

5.2.32.1
5.2.32.2
5.2.32.3
5.2.32.4
5.2.32.5
5.2.33
5.2.33.1
5.2.33.2
5.2.34

5.2.34.1
5.2.35

5.2.35.1
5.2.36

5.2.37

5.3
5.3.1
5.3.1.1

5.3.1.2

5.3.2

5.3.2.1

5.3.3
5.3.3.1

5.3.3.2

5.3.3.3

5.3.3.4

5.3.3.5

5.3.3.6

5.3.3.7

5.3.3.8

5.3.3.9

5.3.3.10
5.3.3.11

5.3.3.12

5.3.3.13

5.3.3.14

5.3.3.15

5.3.3.16

5.3.3.17

5.3.3.18
5.3.3.19

5.3.3.20

5.3.3.21

5.3.3.22

5.3.3.23

5.3.3.24

5.3.3.25

5.3.3.26

5.3.3.27
5.3.3.28

5.3.3.29

5.3.3.30

5.3.3.31

5.3.3.32
5.3.3.33

5.3.4

5.3.4.1
5.3.4.2

5.3.4.3

5.3.4.4

5.3.4.5

5.3.4.6

5.3.4.7

5.3.4.8

5.3.4.9
5.3.4.10
5.3.4.11

5.3.4.12

5.3.4.13

5.3.4.14

5.3.4.15

5.3.4.16

5.3.4.17

5.3.4.18
5.3.4.19
5.3.4.20
5.3.4.21

5.3.4.22
5.3.4.23
5.3.4.24
5.3.4.25
5.3.4.26
5.3.4.27
5.3.4.28

5.3.4.29

5.3.4.30
5.3.4.31
5.3.4.32
5.3.4.33
5.3.4.34
5.3.4.35
5.3.4.36
5.3.4.37

5.3.4.38

5.3.4.39

5.3.4.40
5.3.4.41
5.3.4.42

5.3.4.43

5.3.4.44
5.3.4.45
5.3.4.46
5.3.4.47
5.3.4.48
5.3.4.49
5.3.4.50

5.3.4.51

5.3.5

5.3.5.1
5.3.5.2

5.3.5.3

5.3.5.4
5.3.5.5

5.3.5.6

5.3.5.7

5.3.5.8

5.3.5.9

5.3.5.10
5.3.5.11

5.3.5.12

5.3.5.13

5.3.5.14

5.3.5.15

5.3.5.16

5.3.5.17

5.3.5.18

5.3.5.19

5.3.5.20

5.3.5.21

5.3.5.22

5.3.5.23

5.3.5.24

5.3.6

5.3.6.1

5.3.6.2

5.3.7

5.3.7.1
5.3.7.2

5.3.7.3

5.3.7.4

5.3.7.5

5.3.7.6

5.3.7.7

5.3.7.7

5.3.7.8

5.3.7.9
5.3.7.10

5.3.7.11

5.3.7.12

5.3.8

5.3.8.1
5.3.8.2
5.3.8.3
5.3.8.4

5.3.8.5

5.3.8.6
5.3.8.7
5.3.8.8

5.3.8.9

5.3.9
5.3.9.1
Description of Item

Electro-Mechanical Works
Airfield Ground Lighting ( AGL ) System

Supply, delivery, installation, testing and commissioning of the following LED lamp ( Minimum 30,000h
long life) with light fittings, c/w Frangible coupling : 2inch gas, Coten steel plate, Base mounting
plate : 2inch gas, electrical, Isolation transfomer, connector kit, etc i/c foundation works and likes for a
complete installation and as per ICAO Annex14, Vol 1, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

In addition to the LED lamp light fitting, the cost of the following sub-items shall include
all the associated works mentioned in this item
i) RWY Hligh Intensity Inset type Lights, 20W/2, 6.6A, pref. LED lamp, beams- white ,
white/yellow and 60W Isolation transfomer.
ii) TWY edge light elevated, 5W, 6.6A, pref. LED lamp, beams- blue and 15W Isolation
transfomer.
iii) TWY edge light Inset type Lights, 5W, 6.6A, pref. LED lamp, beams- blue and
15W Isolation transfomer.
iii) Inmtermidiate Holding Position Light (IHPL) Inset type Lights, 15W, 6.6A, pref.
LED lamp, beams- yellow and 30W Isolation transfomer.

Supply, delivery, installation, testing and commissioning of the following Airfield Signs having rotection level
IP45, Coat paint, Height of legend is 800mm, Polycarbonated front panel c/w aluminium housing, breakable
couplings, 150W+15W cold mirror LED lamps 30,000 h, serie power supply from 2.8 to 6.6 A works and likes
for a complete installation and as per Legend impormation - Annex 14, Vol.1, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

a) Sine size 32EA


i) 800mm x1,200mm, TR 200W
ii) 800mm x1,400mm, TR 200W
iii) 800mm x1,600mm, TR 200W
iv) 800mm x1,800mm, TR 200W
v) 800mm x2,000mm, TR 200W
vi) 800mm x2,200mm, TR 200W
vii) 800mm x2,400mm, TR 200W
viii) 800mm x2,600mm, TR 200W
ix) 800mm x2,800mm, TR 200W
x) Breakable Coupling 50mm
b) Foundation Work
i) Foundation W= 1,600mm
ii) Foundation W= 2,200mm
iii) Foundation W= 2,600mm
iv) Foundation W= 2,800mm
v) Foundation W= 3,000mm
vi) Foundation W= 3,200mm
vii) Foundation W= 3,800mm
viii) Foundation W= 4,000mm
ix) Foundation W= 4,400mm
x) Foundation W= 4,600mm
xi) Foundation W= 5,400mm
ACMS

Design, supply, installation, testing and commissioning of Airfield light Control & Monitoring System c/w
Equipment, Cable, Computer, Panel, ect, Control Cable for ACMS loof networks, F.O(Fibre optical)
Single mode 8C, O.F FDF, UPS/ 1Phase 230V, ALL IGBT, 20kVA, Backup 30min and as listed below,
but not limited to, comply with technical specification including all necessary drawings, diagrams and
supporting documents.

ACMS for CAT-I/Ⅱ Operation, Touch screen interface for ATCT and redundant PLC, located at the AGL
substion interconnected via a F.O network, Interface via Dual fieldbus with the CCRs, Neecessary I/O
for the connection of Aux, Equipment. Functionality: In the Control Tower south or Runway 11-29, ATCT
and Maintenance Workstation are Installed, Workstations are Installed, All workstations are connected by a fibre
optic loop, The functionality of the ACMS is control of lights on the Operator Workstations via control of the
monitoring/control units. Remote control and

monitoring, I/O Interface for CCR, Soft On/Off control, Brigtness control (5steps), Back indication of switched
controls/ selected brillinacy, Back indication of brilliancy error for each selected brilliancy, Indication of
shutdown due to over- current and work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning of the following Digital Type Constant Current
Regulator (CCR) comprising of Input power 230V, 50Hz Output Current 6.6A; Remote On/Off, brightness
step 1 to 7 selector; Plug-in high voltage cut out type to isolate the series circuit from the regulator
output c/w 7C-1.5sqmm 0.6/1.0KV XLPE/PVC Screened Control Cable, Required 0.6/1.0KV XLPE/PVC
Power Cable of respective size etc works and likes for a complete installation and as per ICAO Part5, Chapter
3, 3.2.1.4/5/6 and work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.

In addition to the CCR Unit, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) CCR 25 kW (by 1/C -35 Sqmm Power Cable)
ii) CCR 20 kW (by 1/C -35 Sqmm Power Cable)
iii) CCR 15 kW (by 1/C -25 Sqmm Power Cable)
iv) CCR 10 kW (by 1/C -16 Sqmm Power Cable)
v) CCR 7.5 kW (by 1/C -10 Sqmm Power Cable)
vi) CCR 4 kW (by 1/C -6 Sqmm Power Cable)

Supply, delivery, installation, testing and commissioning of Plug Cut Out Switch for the Digital Type Constant
Current Regulator (CCR) comprising of Serise cicrit 5kV 20A, Indoor Type; Withstands permanent 5 kV
A.C. circuit voltage etc works and likes for a complete installation and work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning of Series Plug Cut outs panel board for AGL Series
circuit; W2,000 x D450 XH1,1800 for COP (200mmx140mm), Door 3.2T, Front and Side 2.3T etc works and
likes for a complete installation and work should be done as per design, drawing, specification of relevant chapter
and accepted by the Engineer.

LT Distribution Board for CCR Station


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following LT Switchboards. It shall also include protection relays, surge arrestors, electrical & signal
cabling, cable support, terminations, mounting, labelling, associated accessories and building works necessary to
provide the complete system as specified and complying with relevant codes, work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.

i) ACB 600V, 800A-2EA(LV-1,2); 400V, 3HP-4W, 50Hz; Condenser bank 20,15,10kVA, Digital
Meter & etc. SPD 3PH 4W, 50kA Mode, CT, etc

ii) CTTS 600V, 4P 1000AF(LV-3); 400V, 3HP-4W, 50Hz; Condenser bank


20,15,10kVA, Digital Meter & etc. SPD 3PH 4W, 50kA Mode, CT, etc with Interconnection.

iii) LV Distribution Panel(LV-4~6), LV Panel Board for AGL Power Supply, 600V,
3HP-4W, 50Hz, Digital Meter, MAIN ACB 4P 600AF - 1EA, Brench MCB 2P 225AF -
4EA , 2P100AF-4EA, ZCT, PT, CT, ELD 10CCT & etc.
iv) LV Distribution Panel(LV-SVC), Condenser bank 10kVAR*3, Digital Meter & etc,
600V, 3HP-4W, 50Hz, Digital Meter, MAIN ACB 4P 100AF - 1EA.
v) LV Distribution Panel(LV-FIL), ACTIVE FILTER 70A.
vi) Battery and Battery chager(LV-R), Encolse Lead-acid Battery type, 12V 9cells, Back
up 30min, Digital Meter.

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following Engine Generator Set as a complete system as specified and complying with relevant codes,
work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

i) Emergency Generator (GEN-1,2); 3Phase 4Wire 400kW/500kVA, Diesel 415/240V, 50Hz, 1,500rpm; with
Control Panel 2EA, Auto(D.C)Starting, MAIN ACB 4P 1200AF - 1EA, ACB 800A-2EA, Fuel daily tank 490L
x2ea and steel pipe lines, etc. Outer fuel tank 3,000L x 1ea & foundation.

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following PAD mounted Transformer Set i/c MCCBs, SPD, Elbow connector and foundation works
etc. The guaranteed values of finished articles will conform to the tolerances specified in ANSI C57. 12. 00
and as a complete system as specified and complying with relevant codes, work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.

i) 11kV/400/230V, 3Ø 4W, 50Hz. 45kVA,Outdoor Loop Type


ii) 11kV/400/230V, 3Ø 4W, 50Hz. 30kVA,Outdoor Loop Type
i) 230V/400V/11KV, 3Ø 4W, 50Hz. 45kVA,Outdoor Loop Type
ii) 230V/400V/11KV, 3Ø 4W, 50Hz. 30kVA,Outdoor Loop Type

Supply, delivery, installation, testing and commissioning of the following type of Luminaires, including all
cabling works with required Fiber Optic Control Cable in/c accessories, termination, concealed GI conduit,
junction box complete with quick male & female connector, supporting brackets and necessary accessories and
link to respective lighting switches on External including Control Panel Board, Base Foundation etc for
each mast pole and 01 no power tool against 02 nos mast pole etc. and work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

Fixtures: LED Lamp not less than 400W x 3 and High Pressure Sodium 1kW with lamp
6x1000W & ballast.
Mast pole H=25M,(Up Down system)
Construction of Manhole & Pull Pit comprising of Hole Cover-iron, Excavation & Backfilling, Pulling-in
irons, Grounding rod,w/Clamp 18mmx2,400L-1EA, W/ Exothermic Connector, Tinned Bare copper
conductor, 16mm2-5M i/c related accessories and grounding material and work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.

i) TYPE-A(2.6M x 1.6M x 2.0M), Cable rack 6 arm (Manhole)


i) TYPE-B(1.6M x 1.3M x 1.1M), Cable rack 4 arm (Manhole)
i) TYPE-C(1.0M x 1.0M x 1.0M), Cable rack 2 arm (Pull Pit)

Duct Bank (Underground Ductbanks all in accordance) - work should be done as


per design, drawing, specification of relevant chapter and accepted by the Engineer.

Duct 20x100mm diameter(Type-EO1)


PVC 100mm X16, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
Concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 20x100mm diameter(Type-EO2)
PVC 100mm X18, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 18x100mm diameter(Type-EO3), Cross Part
PVC 100mm X16, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 16x100mm diameter(Type-EO4)
PVC 100mm X14, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 16x100mm diameter(Type-EO5), Cross Part
PVC 100mm X14, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 16x100mm diameter(Type-EO6)
PVC 100mm X12, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 16x100mm diameter(Type-EO7), Cross Part
PVC 100mm X12, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 12x100mm diameter(Type-EO8)
PVC 100mm X8, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 9x100mm diameter(Type-EO9)
PVC 100mm X7, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 8x100mm diameter(Type-E10)
PVC 100mm X7, PE 100mmX7(W/SCD25mmX5)X7
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 8x100mm diameter(Type-E11)
PVC 100mm X4, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 6x100mm diameter(Type-E12)
PVC 100mm X4, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 6x100mm diameter(Type-E13), Cross Part
PVC 100mm X4, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 4x100mm diameter(Type-E14)
PVC 100mm X3, PE 100mmX1(W/SCD25mmX5)X1
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 4x100mm diameter(Type-E15)
PVC 100mm X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 4x100mm diameter(Type-E16), Cross Part
PVC 100mm X3, PE 100mmX1(W/SCD25mmX5)X1
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 8x100mm diameter(Type-E17)
PVC 100mm X4, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Grounding & Counterpoise wire - work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
Duct Bank Section
i) Tinned copper BC 25Sqmm
ii) Earth Rod 18mm x2,400mm
iii) Bentonite 25kg/1Bag
AGL Section
i) Earthing wire Tinned copper BC16Sqmm
ii) Eatth Rod 18mm Sq x2,400mm
iii) Bentonite 25kg/1Bag
iv) Excavation & Backfilling
Grounding
Provision of earthing of equipment in the CCR hall along with testing point as per
drawing and as required.
AGL Lamp to lamp PE Pipes

Supply, delivery, installation of PE 54mm Pipe Conduit, PVC 54mm, Coupling, spacer, warning tape i/n concrete
210mpa, Excavation & Backfilling works and likes for a complete installation and work should be done as
per design, drawing, specification of relevant chapter and accepted by the Engineer.

Street Lighting

Supply, delivery, installation of Street lighting pole i/c lamp, auto control unit etc with waterproof type electric
shock protector(W/ELCB) and connecting material, conduit & foundation includes excavation & backfilling
works and work should be done as per design, drawing, specification of relevant chapter and accepted by the
Engineer.

i) Lighting ploe h=15m, steel 3.2t, HDG, LED lamp 400W x6


ii) Lighting ploe h=10m, 1arm, STS 304, LED lamp 150W x1
iii) Lighting ploe h=10m, 2arms, STS 304, LED lamp 150W x2
iv) Lighting ploe h=5m, STS 304, LED lamp 70W x2
v) Lighting Panel Board 6circuits, Stand Type & MCCB 4P 60A, ELCB 2P 20A-8,
Auto Control Unit, etc.
vi) Conduit FEP 65mm
vii) Conduit FEP 50mm
viii) Duct 4x100mm diameter(Type-E16), Cross Part
ix) Lighting 15M pole Foundation
x) Lighting 10M pole Foundation
xi) Lighting 5M pole Foundation
xii) Lighting Panel Board Foundation
CABLE WORKS

Supply, delivery, installation of the following cable and work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
AGL Cable

Supply, delivery, installation of 5 KV XLPE primary cable as described in technical specification 1C- 6 sqmm and
plug receptacle with connection kit on under ground/through PVC pipe/ pavement/duct and work should be done
as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Supply, delivery, installation of 600 KV 2 PNCT/PVC insulated, PVC sheathed cable 2C 4 sq mm including plug
and receptacle to connect fitting/transformer and work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

NORMAL CABLE
15KV XLPE/PVC, 1/C- 35Sqmm
0.6/1kV XLPE/PVC, 1/C- 185Sqmm
0.6/1kV XLPE/PVC, 1/C- 120Sqmm
0.6/1kV XLPE/PVC, 1/C- 50Sqmm
0.6/1kV XLPE/PVC, 1/C- 25Sqmm
0.6/1kV XLPE/PVC, 1/C- 35Sqmm
0.6/1kV XLPE/PVC, 1/C- 16Sqmm
0.6/1kV XLPE/PVC/CVVS, 10/C- 1.5Sqmm
0.6/1.0KV XLPE/PVC, 1/C- 35Sq-4L
0.6/1.0KV XLPE/PVC, 1/C- 16Sq-2L
0.6/1.0KV XLPE/PVC, 1/C- 10Sq-2L
0.6/1.0KV XLPE/PVC, 2/C- 4Sq
GV wire, 1/C- 70Sqmm
GV wire, 1/C- 95Sqmm
GV wire, 1/C- 6Sqmm
Ground Copper wire 16sq
Ground Copper wire 10sq
Control Cable
F/O single mode 8C
Accessories
MV Terminal kit
MV Direct access Suplacing kit

HVAC SYSTEM
WATER CHILLER UNIT :
WATER COOLED CENTRIFUGAL CHILLER

Supply, installation, testing and commissioning of High Efficiency Water Cooled Screw/Centrifugal type Chiller
with oil free magnatic bearing type of multiple semi hermetic screw/centrifugal compressor having capacity not
less than 1,407 KW (400 US RT) when 4,884 L/min (1290 US GPM) of condenser water entering at 32°C
(89.6°F) and leaving at 37°C (98.6°F).

The Chiller shall be shell and tube water cooled condenser, shell and tube flooded evaporator with insulation, flow
switches at chiller and condenser water pipe, vibration isolators, integral refrigerant piping and wiring, accessories
as required and called for, automatic and safety controls mounted in central console panel and all mounted on a
steel frame complete as per specifications.

Motor shall be suitable for 400±10%V, 50 Hz, 3 phase AC supply. Refrigerant used shall be Ozone friendly R-
134a as detailed in specifications. Chiller shall have electronic expansion valve, serial card for backnet, input
remote demand limit, touch visual display, etc. All components including compressor shall be from the same
The chilled water capacity shall be 4,4034 L/min (1066 US GPM) when entering at 12°C (53.6°F) and leaving at
30°C44.6°F. The full load efficiency at rated condition of the chiller shall not be more than 0.50 kW/RT.
AHRI/Eurovent Certified rating report must be submitted to prove both full load kW/RT.

The cooler and condenser shall have water side fouling factor of Evaporator 0.000102 hr- ft2-oF/Btu and
Condenser 0.000250 hr-ft2-oF/Btu. The water pressure drop in the cooler and condenser water shall not exceed 20
ft WG. Chiller shall be capable to have smooth operation at minimum load of 20%.

The unit shall be complete with microprocessor based control panel with graphic display panel and also c/w open
protocol which is compatible to any building management system. The capacity control shall be fully automatic
and based on chilled water outlet temperature. Vibration isolator shall be included with each unit.

Each machine shall be completed with integrated factory fitted inbuilt inverter for proper capacity control and to
reduce starting inrush current. Each unit shall be
assembled, wired, tested and factory charged. Details as per Technical Specification.
Capacity of Chiller : 1,407 KW (400 US RT)
COOLING TOWER :

Supply, installation, testing and commissioning of enclosed type, axial-flow induced draft cross flow rectangular
type cooling tower. It shall be completed with make-up water valve, float assembly, access door, motor, fan ( FAN
CAPACITY 15 KW TYPE OF FLOW AXIAL, eliminators, steel support, ladder etc. Cooling Tower details along
with accessories shall comply in accordance with specification including Immersion type temperature sensor and
other accessories The Cooling Tower having capacity of Cooling 1,920,000 KCAL/H(500 CRT) of water from
32°C (89.6°F) to 37°C (98.6°F) when
outside air wet bulb temperature is 24°C.The Cooling Tower shall be constructed of Fibre Glass Reinforced
Polyster (FRP) and galvanized Iron components. Drift loss shall not be more than 0.5% of water flow. The power
supply shall be 400V±10/3ph/50Hz. COOLING tower water flow rate 4,884 l/min (1290 US GPM) operation
weight 6250 kg.The cooling shall be CTI certified. Details as per Technical Specification.

Cooling Capacity : 4884 L/m (1290 US GPM)


FREE COOLING HEAT EXCHANGER
Supply and installation of free cooling plate type heat exchanger with standard
accessories as per following specification
Capacity: 1407 kW
Max. working prssure: 1000 kPa
CENTRIFUGAL PUMPS :

Supply, installation, testing and commissioning of end Suction, vertical discharge Centrifugal Pumps as per
following capacities and specifications. Each pump shall be complete with integrally coupled electrical motor of
appropriate capacity, flexible coupling, spacer unit, support base, mechanical seal, safety cover, spring isolator etc.
complete and all other standard components. Each pump shall be minimum 70% efficient and motor shall be
heavy duty type suitable to operate at 400C ambient temperature. The speed of the motor shall not exceed 1450
rpm. The supply power shall be 360v~440v/3ph/50Hz. Details as per Technical Specification.

Contractor will calculate the head loss calculation before place the order.
Chilled Water Pumps
Flow Capacity : 4034 L/min (1066 US GPM)
Total head: 47 Meter (150 ft.) PA
Condenser Water Pumps
Flow Capacity : 4884 L/m (1290 US GPM)
Total head: 19 Meter (150 ft.) PA
CHEMICAL DOSING UNIT :
Supply, installation, testing and commisioning of Chemical Dosing Unit (Pot Feeder) complete with necessary
chemicals for treatment of condenser water and chilled water in order to control growth of algae, bacteria,
biological componets and control of corrosion of pipe surfaces. Pot Feeder and chemicals for treatment of
condenser water and chilled water. Details as per Technical Specification.

Capacity 6500 US Gpm


AIR HANDLING UNIT (AHU)

Supply, installation, testing and commisioning of weather proof type, floor mounted, horizontal type, horizontal
discharge draw throw type Air Handling Unit. Each shall be constructed with 40mm thick insulated (Insulation
materials:PU) double skin panel with thermal barrier, outside power coated casing and shall be completed with
AIRFOIL type fan with external motor, variable frequency drive with pressure sensor, copper cooling coil with
aluminium fin, washable filter before coil, 85% cfficiency bag filter before coil, extended drain pan, vibration
isolator etc. Drain pan shall be constructed with stainless steel, tapered towards collection and shall be zero

AHU-1
Air flow Capacity : 50,600 m3/hr (29854 CFM)
Statics Pressure (S.P) : 1,144 PA
Entering Air Temparature : 27℃ DB & 20 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.5℃ WB
Chilled water flow rate : 1,151 LPM (304 US GPM)
AHU-2
Air flow Capacity : 50,400 m3/hr (29736 CFM)
Statics Pressure (S.P) : 1,078 PA
Entering Air Temparature : 27.5℃ DB & 20.3 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.4℃ WB
Chilled water flow rate : 1,221 LPM (323 US GPM)
AHU-3
Air flow Capacity : 41100 m3/hr (23838 CFM)
Statics Pressure (S.P) : 1,012 PA
Entering Air Temparature : 26.5℃ DB & 19.4 ℃ WB
Leavring Air Temparature : 13.6℃ DB &12.7℃ WB
Chilled water flow rate : 849 LPM
AHU-4
Air flow Capacity : 31000 m3/hr (17980 CFM)
Statics Pressure (S.P) : 1,012 PA
Entering Air Temparature : 26.5℃ DB & 19.4 ℃ WB
Leavring Air Temparature : 13.6℃ DB &12.7℃ WB
Chilled water flow rate : 849 LPM
AHU-5
Air flow Capacity : 32800 m3/hr (19024 CFM)
Statics Pressure (S.P) : 1,078 PA
Entering Air Temparature : 27.2℃ DB & 20.0 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.4℃ WB
Chilled water flow rate : 757 LPM
AHU-6
Air flow Capacity : 32700 m3/hr (18966CFM)
Statics Pressure (S.P) : 1,012 PA
Entering Air Temparature : 28.0℃ DB & 20.7 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 853 LPM
AHU-7
Air flow Capacity : 32700 m3/hr (18966CFM)
Statics Pressure (S.P) : 963 PA
Entering Air Temparature : 27.6℃ DB & 19.4 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.4℃ WB
Chilled water flow rate : 806 LPM
AHU-8
Air flow Capacity : 39700 m3/hr (23026CFM)
Statics Pressure (S.P) : 1,037 PA
Entering Air Temparature : 26.2.0℃ DB &19.1 ℃ WB
Leavring Air Temparature : 13.9℃ DB &12.9℃ WB
Chilled water flow rate : 738 LPM
AHU-9
Air flow Capacity : 35700 m3/hr (20706CFM)
Statics Pressure (S.P) : 1095 PA
Entering Air Temparature : 26.8℃ DB & 19.6 ℃ WB
Leavring Air Temparature : 13.9℃ DB &12.9℃ WB
Chilled water flow rate : 735 LPM
AHU-10
Air flow Capacity : 37700 m3/hr (21866CFM)
Statics Pressure (S.P) : 963 PA
Entering Air Temparature : 27.0℃ DB & 19.9 ℃ WB
Leavring Air Temparature : 13.6℃ DB &12.6℃ WB
Chilled water flow rate : 839 LPM
AHU-11
Air flow Capacity : 53200 m3/hr (30856CFM)
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 26.4℃ DB & 19.3 ℃ WB
Leavring Air Temparature : 13.8℃ DB &12.8℃ WB
Chilled water flow rate : 1051 LPM
AHU-12
Air flow Capacity : 38900 m3/hr (22562CFM)
Statics Pressure (S.P) : 1095 PA
Entering Air Temparature : 28.5℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 1078 LPM
AHU-13
Air flow Capacity : 34400 m3/hr (19952CFM)
Statics Pressure (S.P) : 979 PA
Entering Air Temparature : 28.5℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 953 LPM
AHU-14
Air flow Capacity : 31400 m3/hr (18021CFM)
Statics Pressure (S.P) : 979 PA
Entering Air Temparature : 28.2℃ DB & 20.9 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 845 LPM
AHU-15
Air flow Capacity : 5700 m3/hr (3306CFM)
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 28.5℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 158 LPM
AHU-16
Air flow Capacity : 6100 m3/hr (3538CFM)
Statics Pressure (S.P) : 930 PA
Entering Air Temparature : 28.4℃ DB & 21.4 ℃ WB
Leavring Air Temparature : 14.9℃ DB &13.7℃ WB
Chilled water flow rate : 155 LPM
AHU-17
Air flow Capacity : 2900 m3/hr (1682 CFM)
Statics Pressure (S.P) : 880 PA
Entering Air Temparature : 28.0℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 14.9℃ DB &13.4℃ WB
Chilled water flow rate : 72 LPM
AHU-18
Air flow Capacity : 11400 m3/hr (6612 CFM)
Statics Pressure (S.P) : 930 PA
Entering Air Temparature : 28.9℃ DB & 21.9 ℃ WB
Leavring Air Temparature : 14.9℃ DB &13.7℃ WB
Chilled water flow rate : 305 LPM
AHU-19
Air flow Capacity : 9000 m3/hr (5220CFM)
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 36.3℃ DB & 27.0 ℃ WB
Leavring Air Temparature : 19.8℃ DB &18.7℃ WB
Chilled water flow rate : 301 LPM
AHU-20
Air flow Capacity : 3500 m3/hr (2030CFM)
Statics Pressure (S.P) : 996 PA
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 36.3℃ DB & 27.0 ℃ WB
Leavring Air Temparature : 19.8℃ DB &18.7℃ WB
Chilled water flow rate : 117 LPM
CHILLED WATER FAN COIL UNIT (FCU)

Supply, installation, testing and commissioning of Ceiling Mounted concealed type Chilled Water Fan Coil Units
having cooling capacities as mentioned below. Each unit shall be complete with chilled water cooling coil,
centrifugal fan, fan motor, washable air filter, insulated return air chamber, insulated condensate tray etc. Each unit
also shall be complete with insulated enclosue, duct collar, hangers, vibration isolators, vent port built in inside the
unit. The fan shall have the capacity to handle required air against an external static pressure of the fan. The unit
shall have at lest 4 row coil depth and have the following capacities at chilled water entering the coil at 44.60F and
leaving the coil at 53.60F. FCU shall be controlled and monitor from BMS. Details as per Technical
Sepecification.

The unit shall operate when supplied with 200v~240v/50 hz/1ph power.
The Fan Coil Units shall have the capacity to cool air from 750F DB/650F WB and
leaving the coil at 550F DB / 540F WB.
FCU-01
Cooling Capacity : 5710 W / 1.5 TR
Air flow : 540 cfm
Chilled Water Flow Rate :3.6 US Gpm
External static pressure: 0.4 inch WG
FCU-02
Cooling Capacity : 4940 W / 1.6 TR
Air flow : 630
Chilled Water Flow Rate : 3.6 US Gpm
External static pressure: 0.4 inch WG
FCU-03
Cooling Capacity : 7,190 W / 2 TR
Air flow : 720 cfm
Chilled Water Flow Rate : 4.8 US Gpm
External static pressure: 0.4 inch WG
FCU-04
Cooling Capacity : 11,490 W / 3.25TR
Air flow:1080 cfm
Chilled Water Flow Rate :7.2 US Gpm
Variable Refrigerant Flow /Volume (VRF/VRV) System with Fan Coil Unit
VRF/VRV Condensing Units (Outdoor unit)

Variable Refrigerant Flow (VRF/VRV) units having following cooling capacities and other parameters as
mentioned below. Each unit shall have multiple Inverter type variable speed Compressors, DX Condenser with
Copper tube & Aluminum Fins.
Condenser Fan with Fan guard, Terminal board, over current protector, Voltage Transformer, Temperature sensor,
Pressure sensors, built in Oil separator & Accumulator etc, complete in all respect. The unit shall operate when
supplied with 400±10% V / 50hz
/ 3 Ph Electric power.

The supply includes all accessories to complete VRF mechanism including Voltage free
contact for connection with BMS.
Condenser air inlet temperature: 35 deg C
Refrigerant: R410A, Factory Charged
Compressor type: Inverter driven type
ESP of Outdoor unit Fan: 80 Pa
COP: 3.6 or higher
VRF Outdoor unit: Capacity : 62.0 kw
VRF/VRV Fan Coil Unit (Indoor Unit)
Evaporative units hoving cooling copacities as mentioned below. Each unit sholl complete with EXV, washable
filter , variable fan speed controller etc. Each unit shall
run with 50hz-1ph-220V power supply. Each unit shall have individual remote
Air entering to cooling coil: 27 0C DB / 19 0C WB
Type: Cassette Type ceiling hide away type
Wall mounted Networking Thermostat,
Refrigerant Branch Pipe Connector (RefNet or equivallent)
Ceiling Concealed Cassette Type Fan Coil Unit
4-Way Cassette Type
Cooling capacity : 8.3 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 10.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.8 kw
External static pressure : 0.40 inch WG
Cooling capacity : 9.9 kw
External static pressure : 0.40 inch WG
Cooling capacity : 11.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.5 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.7 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.4 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.5 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.9 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.3 kw
External static pressure : 0.40 inch WG
Cooling capacity :7.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :3.7 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :5.5 kw
External static pressure : 0.40 inch WG
Cooling capacity :4.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.4 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.1 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 12.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :6.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :3.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 2.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :7.0 kw
External static pressure : 0.40 inch WG
2-Way Cassette Type
Cooling capacity : 3.7 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.4 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.9 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.5 kw
External static pressure : 0.40 inch WG
Floor Stand Type Indoor unit
Cooling capacity : 7.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.1 kw
External static pressure : 0.40 inch WG
Cooling capacity : 10.1 kw
External static pressure : 0.40 inch WG
Cooling capacity : 8.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 11.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.0 kw
External static pressure : 0.40 inch WG
Cooling capacity :12.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :8.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :5.7 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.9 kw
External static pressure : 0.40 inch WG
VENTILATION FAN :

Supply and installation of cabinet type supply air/exhaust air fan complete with fan, fan motor, fan section,
supports, starters, switches, casing, air filter, mounting accessories and all other components complete in all
respect. Details as per Technical Specification.

SF-1
Flow Capacity : 25,400 m3/hr
External static pressure : 250 PA
SF-2
Flow Capacity : 25,300 m3/hr
External static pressure : 250 PA
EF-3
Flow Capacity : 14700 m3/hr
External static pressure : 300 PA
EF-4
Flow Capacity : 12100 m3/hr
External static pressure : 300 PA
EF-5
Flow Capacity : 10900 m3/hr
External static pressure : 300 PA
SF-6
Flow Capacity :10500 m3/hr
External static pressure : 250 PA
EF-7
Flow Capacity : 10000 m3/hr
External static pressure : 250 PA
EF-8
Flow Capacity : 8100 m3/hr
External static pressure : 300 PA
SF-9
Flow Capacity : 5400 m3/hr
External static pressure : 250 PA
EF-10
Flow Capacity : 3800 m3/hr
External static pressure : 250 PA
EF-11
Flow Capacity : 2600 m3/hr
External static pressure : 300 PA
EF-12
Flow Capacity : 2200 m3/hr
External static pressure : 250 PA
EF-13
Flow Capacity : 2150 m3/hr
External static pressure : 250 PA
SF-14
Flow Capacity : 2100 m3/hr
External static pressure : 250 PA
EF-15
Flow Capacity : 1900 m3/hr
External static pressure : 250 PA
EF-16
Flow Capacity : 1700 m3/hr
External static pressure : 250 PA
EF-17
Flow Capacity : 1500 m3/hr
External static pressure : 250 PA
EF-18
Flow Capacity : 1290 m3/hr
External static pressure : 250 PA
EF-19
Flow Capacity : 480 m3/hr
External static pressure : 30 PA
EF-20
Flow Capacity :600 m3/hr
External static pressure : 30 PA
EF-21
Flow Capacity : 400 m3/hr
External static pressure : 250 PA
EF-22
Flow Capacity :340m3/hr
External static pressure : 30 PA
Heat Recovery Ventilation:
Supply, installation and commissioning of heat recovery ventilation unit completed with cabinet, fresh air and
exhasut air centrifugal type forward curved fans, cross- flow type
heat recovery module, filters etc. as per following capacity.
Air flow Capacity :2400 m3/h
External static pressure : 1 inch WG
Air flow Capacity :2800 m3/h
External static pressure : 1 inch WG
Air flow Capacity :3400 m3/h
External static pressure : 1 inch WG
Air flow Capacity :3200 m3/h
External static pressure : 1 inch WG
Air flow Capacity :800 m3/h
External static pressure : 1 inch WG
Air flow Capacity :2900 m3/h
Chilled Water Valves & Accessories :
Supply, installaion, testing and commissionign of steel /cast iron Water Valves of different sizes for use in chilled
water and condenser water lines. The valves shall be
flanged type from size 2 inch dia.
Valves shall be threaded type below 2 inch dia. Valves shall be complete will with all
standard fittings and accessories. Details as per Technical Specification.
Y STRAINER :
Supply, installation, testing and commissioning of Y-Strainer. Details as per Technical
Specification.
250 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
FLEXIBLE PIPE CONNECTOR :
Supply, installation, testing and commissioning of Flexible Pipe Connector. Details as
per Technical Specification.
250 mm dia
100mm dia
80mm dia
65mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Globe Valve
250 mm dia
100 mm dia
Check Valve
250mm Dia
200mm dia
Butterfly Valve
250 mm dia
100mm dia
80mm dia
65mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Motorized Butterfly Valve
250mm dia
200mm dia
Gate Valve
250mm dia
200mm dia
150mm dia
100 mm dia
80 mm dia
Solenoid Valve
100mm dia
80mm dia
65mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Solenoid Valve
25 mm dia
20 mm dia
Ball Valve
50 mm dia
40 mm dia
32 mm dia
25 mm Dia
20 mm Dia
Automatic Air Vent
20 mm Dia
Drain Valve
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
Water Flow Balancing Valve :
Supply and installation of flow balancing valve complete with all accessories and components for balancing and
recording of rates of chilled water flow through pipes.
Details as per Technical Specification.
250 mm dia.
METERING DEVICES :
Supply, installation and testing of following Metering Devices. Details as per
Technical Specification.
Pressure Gauge (Size : 4" dia , Range 0 ~ 300 PSI)
Pipe thermometers (0 ~ 150o F)
Pipe thermosate (0 ~ 150o F)
WATER SOFTENER
Supply, installation, testing and commissioning of raw water softener as per detail
specification and instructions of Engineer-in-charge. Capacity : 240 Us Gpm
AIR SEPARATOR:
Supply and installation of Air Separator as per detail technical specification & as per
direction of Engineer- in-charge.
Capacity : 5000 Us gpm
Capacity : 7500 Us gpm
BUILDING MANAGEMENT SYSTEM (BMS) :

Supply and installation of Building Management and Control system suitable to control operation, monitoring
and management of the (HVAC) system, Electrical system, Fire Safty & Security system, Plumbing system, Lift
management system from a central location, log and retrieve data of the operation and failure status of the

The system shall be complete with sensors, transducers, transmitters, relays, direct digital controllers (DDC),
network units, computers, printers, cables, relevant hardware and software complete in all respect. BMS shall be
as per BACnet protocol. The supply power shall be 200v ~ 250v/1ph/50hz power. Details as per Technical

AIR TERMINALS :

Air terminals shall be constructed with extruded aluminum with powder coating finishing. Thickness shall
be not less than 18 SWG. Sizes mentioned are neck sizes.

SUPPLY & RETURN AIR TERMINALS :

Supply and installation of Ceiling Mounted Supply Air Diffuser made of extruded Aluminium having neck
size as per following. Details as per Technical Specification.

SYPPLY ROUND DIFFUSER:


Dia 300 mm
Dia 250 mm
RETURN SQUARE GRILL:
(450mm x 450mm )
(400mm x400mm)
(300mm x 300mm)
(500mm x 500mm)
(600mm x 600mm)
(800mm x 800mm)
(150mm x 150mm)
SUPPLY & RETURN AIR GRILLE :
Supply and installation of Ceiling Mounted/Wall Mounted Return/ Exhaust Air Grilles made of extruded
aluminium complete with neck damper having face size as per
following. Details as per Technical Specification.
(1200mmx150mm)
(1500mmX150mm)
(1800mmx 150mm)
(2400mm x 150mm)
(2100mm x 150mm)
(2700mm x 150mm)
(2800mm x 150mm)
(3000mm x 150mm)
(3000mm x 200mm)
(3600mm x150mm)
(900mm x 150mm)
(600mm x 150mm)
FRESH AIR/EXHAUST AIR LOUVER ;
Supply and installation of Wall Mounted Fresh Air/ Exhaust Air Louver made of
aluminum with powder coating. Size as per following. Details as per Technical
1400mm x 700mm)
(1000mm x500 mm)
(550 mm x 300 mm)
(800 mm x 450 mm)
(700 mm x350 mm)
(650 mm x350 mm)
(350 mm x 200 mm)
(950 mm x 500 mm)
(1100 mm x 550 mm)
(1050 mm x550 mm)
(600 mm x300 mm)
(400mm x200 mm)
(550mm x 250mm)
(450mm x 250mm)
(400mm x 200mm)
METAL DUCTING : (Machine Made)
Supply, installation and smoke testing of 120 gsm zinc coating, minimised spangle, JIS G3302 standards of
different sizes as per drawing and design including supply of all
materials and consumable. Details as per Technical Specification.
Ducts made of 20 SWG GP Sheets (1.0 mm)
Ducts made of 22 SWG GP Sheets (0.8 mm)
Ducts made of 24 SWG GP Sheets (0.6 mm)
DUCT INSULATION:

Supply and installation of 15 mm thick, 60 micron aluminium foil backed with self adhesive, class O nitrile rubber
insulation on outside surface of metal ducts including supply of all materials and consumable as per drawing and
detail technical specification. The density shall be 40 to 60 kg/m3 density.

DUCT LINING:
Supply and installation of Acoustic Duct Liner inside the duct according to drawing and
detail technical specification including supply of all materials and consumables.
15 mm thick open cell nitrile rubber acoustic lining with self adhesive having density 140
kg/m3
DUCT FLEXIBLE JOINT :
Duct connected with Fan Coil Units, Air Handling Units, Fans shall be done with Nylex or equivalent Flexible
connection. Width shall be 150 mm. Constructional details shall
have to be shown in Shop drawing.
FLEXIBLE ROUND DUCT :
Supply and installation of flexible round duct of density 16 kg/m3.
300mm
SPLITTER FIRE DAMPER :
Supply and installation of Splitter Fire Damper as per drawing including supply of all
materials and consumable. Details as per Technical Specification.
MANUAL VOLUME CONTROL DAMPER :
Supply and installation of Manual Volume Control Damper including supply of all
materials and consumable. Details as per Technical Specification.
250 mm dia
200 mm dia
275 mm dia
175 mm dia
150 mm dia
BLACK STEEL PRE-INSULATED PIPES :

Supply, installation, testing and commissioning of class C heavy black steel pipes with rigid polyurethane foam of
density 45 kg/m3 and galvanised steel spiral outside lockseamed of 0.5 to 0.6 mm thick for all the chilled water
piping system including cutting, edge preparation, welding etc. Pipe hanger/isolator boxes with spring isolators,
hanger rods, stell supports, anchors, all materials and consumable in this connection shall be supplied by the
contractor under this head. Details as per Technical Specification.

450 mm dia.
400 mm dia.
300 mm dia.
250 mm dia.
200 mm dia.
150 mm dia.
350 mm dia.
100 mm dia.
125 mm dia.
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
12 mm dia
Refrigerant Pipe & Accessories
Refrigerant Piping shall be medium grade (L) Copper piping with long bend, support,
hangers, other accessories.
Pipe shall be c/w Nitrile rubber insulation of min 19mm thick.
Ø 6.4mm, thicknes: 0.8 mm
Ø 9.5mm, thicknes: 0.8 mm
Ø 12.7mm, thicknes: 1 mm
Ø 15.9mm, thicknes: 1 mm
Ø 19.1mm, thicknes: 1 mm
Ø 22.2mm, thicknes: 1.2 mm
Ø 28.5mm, thicknes: 1.3 mm
Ø 34.9mm, thicknes: 1.5 mm
R-410a Refrigerant Gas Charge as per Calculation and Manufacturer
Nitrogen Flash and pressure test as per manufacturer recommendation.
Tray for VRF Refrigerant Pipe :

Supply, Fitting, Fixing of Tray System with all necessary hanger, support
,accessories and fittings, Fixing for commissioning of the equipment including all related works as follows
technical specification, drawing and time to time site instruction from Consultant / Owner/Engineer.
uPVC PIPES :
Supply, installation and testing of water grade uPVC pipes of the following sizes including supply and
installation of uPVC sockets, elbows, tees, traps, hangers, unions,
other consumable, etc. complete in all respect.
50 mm dia.
40 mm dia
32 mm dia.
20mm dia.
25mm dia.
CONDENSATE DRAIN PIPE INSULATION :
Supply and installation of nitrile rubber tube insulation of thickness 13 mm on all
condensate drain pipe lines including supply of all materials and consumable. Details as per Technical
Specification.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
20 mm dia.
Refinet :
Refinet for indoor suction
Refinet for indoor dicharge
EXPANSION TANK :

Supply and installation of closed type cylindrical expansion tank made of high quality PVC/Plastic. Tank having
connection for expansion pipe, feed water line, overflow line, drain line, appropriately rated make-up water pump,
safety valves and other accessories complete in all respect. The tank shall be installed 5 ft. above the top level of
chilled water piping. The tank shall be insulated with 25 mm thick insulation.

Capacity : 1000 gallons


MAKE-UP WATER TANK WITH FLOAT VALVE:

Supply and installation of high quality PVC/Plastic make-up water Tank along with adequately rated make-up
water pump, for make-up of water for cooling towers. The tank shall have connection for, feed water line,
overflow line, drain line etc. complete in all respect.

Capacity : 1500 gallons


Tagging, Identification and Painting
Tagging, identification and painting of Chillers, Pumps, AHUs, Fans, Pipings,
Cablings, etc. as per recommendation of the Consultant.
Testing, Commissioning and Balancing ( Chiller & VRF)

After proper installation and the system shall be tested, commissioned and balanced as per direction and
recommendation. Pipe work shall be tested at a test pressure of 10 Kg/CM2 for 24 hours without any link. Leak
testing shall be done for ductwork. Running each equipment independently shall do individual testing. System
charging with refrigerant if required shall be done as per manufacturer recommendation. All controls shall be
balanced properly.

After proper testing, commissioning and balancing the system shall run for seven days upto the satisfaction of the
owner. The contractor shall provide an operation and
maintenance training to the maintenance group deputed by the owner.

MECHANICAL EQUIPMENTS
ELEVATOR & ESCALATOR
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following Passenger lift (motor room-less type) complete with car, control panel, traction
machine (permanent magnet synchronous motor type), gearless, oil free, steel suspension ropes, safety
devices, guide rails, push buttons, with other necessary accessories etc. complete including counter weight
as required, suitable for installation & use in tropicalised country like Bangladesh (considering
ambient temperature from 00C to 460C and relative humidity from 40% to 98%) & as per detailed specifications
and standards as mentioned below herewith :

Brand & country of origin :


Fujitec (Japan), Hitachi (Japan), Kone (Finland), Mitsubishi (Japan), Otis (USA / Japan / France), Schindler
(Switzerland), Thyssenkrupp (Germany) or equivalent product; provided the lift manufacturing company
shall be a multinational one and shall have lift manufacturing capability for speed 10 m / sec
(minimum), also shall have lift manufacturing experience in their own factory for a period of not less than 60
years and the proposed brand of lift shall be manufactured and tested in FINLAND / FRANCE / GERMANY /
JAPAN / SWITZERLAND / UK / USA, complying all other detailed specifications stated in the item and
complete with provision of luminaries, lift car wall, floor & door finishes (as per the detail drawings &
equipment schedule), inclusive of necessary materials and supply, delivery, installation of CCTV cameras
inside all lifts, inclusive testing, commissioning and interface with PTB CCTV
System, c/w, Cable & GI conduit, etc in order to meet the functional intent of the system.

i) 24 persons (2000kg / 2100kg) Lift (Speed = 2.0 m/s)


ii) 17 Persons (1350Kg / 1400Kg) Lift up to 9th floor for Control Tower Building
(Speed = 2.5 m/s - 3.0 m/s)

Supply, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of Escalator complete with cladding finishes (as per the detail drawings & equipment schedule)
including all necessary cablings, conduits, trunking, labelling, devices, equipment, structural requirement in
order to meet the functional intent of the system.

i) Escalator size 11.0 m ~ 12.0 m


ii) Escalator size 15.0 m ~ 16.0 m
PASSENGER BOARDING BRIDGE

Boarding Bridges complete; from approved manufacturer; factory fabricated, factory finished, preasembled
in units, assembled and erected in position; including all associated electrical, lighting and control
systems, all anchor bolts, base plates, supports, fittings, painting, fixings and sealants including foundation
and civil works. Extended Lenght should be calculated from the following limit to dock all type of aircraft.

PBB Models (Glass wall Tunnel Type)


In addition to the Passenger Boarding Bridge, the cost of the following sub-items shall
include all the associated works mentioned in this item
a) Double Docking System
i) 3 tunnels, max 32 m ~ 35 m
ii) 2 tunnels, max 28 m ~ 29 m
b) Single Docking System
i) 2 tunnels, max 28 m ~ 29 m
Sub Total
BAGGAGE HANDLING SYSTEM
Arrival Baggage System (In-Bound Baggage)
Supply, delivery, installation, testing and commissioning of arrival baggage claim
carousel (flat type) c/w controls, electrical, cabling, conduits & trunkings and likes for a complete installation

In addition to the arrival baggage claim carousel, the cost of the following sub-items shall
include all the associated works mentioned in this item
i) 76 Meters, Flat Reclaim Carousel.
ii) 66 Meters, Flat Reclaim Carousel.
Supply, delivery & installation of arrival baggage conveyors (Breakdown Conveyor) c/w controls, photocells,
electrical, cabling, conduits & trunkings and likes for a complete
installation
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Horizontal Conveyor (2 Segments)
ii) Incline/Decline Conveyor (2 Segments)
iii) Queuing Conveyor (Min: 1.2 M in Length)
Supply, delivery & installation of 90 deg power curve c/w controls, photocells, electrical,
cabling, conduits & trunkings and likes for a complete installation
In addition to the power curves, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) 90 Degree Power Curve (3.628 Mtr Each)
Supply, delivery & installation of heavy duty stainless steel roller beds and likes for a
complete installation
In addition to the roller beds, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Roller Beds (3 Nos. & 2 meter in length each)
Supply, delivery, installation, testing and commissioning of Arrival X-ray Machine (Inline) for Custom
Screening-Standard Size Baggage c/w UPS, associated conveyors,
S.S roller belts, operator workstation and other necessary accessories.

Supply, delivery, installation, testing and commissioning of fire/security doors and draft curtains c/w controls,
photocells, electrical, cabling, conduits & trunkings, interfacing and coordination with various trades as
specified, audible and visual warning signages, certification and likes for a complete installation

Supply, delivery, installation, testing and commissioning of emergency stop buttons c/w controls, electrical,
cabling, conduits & trunkings, interfacing and coordination with various trades as specified, audible and
visual warning signages and likes for a complete installation

Supply and installation of the electrical control panels housing the motor controls, starters, control relays,
cabling works, cable supports and motor protection relays to control and interlock the various components
of the system for proper starting and stopping of the system.

Departure Baggage System (Out-Bound Baggage)

Supply, delivery & installation of Passengers Check-in Counter / Desk made of GRP with operators &
passengers display of weighing scale system and accessories, c/w controls, key switch, electrical, cabling,
conduits & trunkings, emergency stop and likes for a complete installation.

In addition to the Check in Counter / Desk, the cost of the following sub-items shall
include all the associated works mentioned in this item
i) Check-in Counter / Desk (36 Nos. included in item No. 5.3.4.22)
Supply, delivery & installation of 1.2m long and 600mm wide Scale Conveyors with load
cells and accessories, c/w controls, photocells, electrical, cabling, conduits & trunkings and likes for a complete
installation.
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Check-in Scale Conveyor

Supply, delivery & installation of 1.2m long and 600mm wide Induction Conveyors and
accessories, c/w controls, photocells, electrical, cabling, conduits & trunkings and likes for a complete installation

In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Check-in Induction Conveyor
Supply, delivery & installation of outbound take-away/collection conveyors at the check- in island c/w controls,
photocells, electrical, cabling, conduits & trunkings and likes for a
complete installation
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Take-away/collection Conveyor-1 (1/2 Segments)
ii) Take-away/collection Conveyor-2 (1/2 Segments)
iii) Take-away/collection Conveyor-3(1/2 Segments)

Supply, delivery & installation of departure baggage conveyors c/w controls, photocells, electrical, cabling,
conduits & trunkings and likes for a complete installation

In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Horizontal Conveyor (Min 12 segments)
ii) Queuing Conveyor (Min: 1.2 M in Length)
iii) Horizontal Conveyor (Min 4 segments) for OOG conveyor.
iv) Queuing Conveyor (Min: 1.2 M in Length) for OOG conveyor.
Supply, delivery & installation of Auto Wheel Diverters, c/w controls, photocells,
electrical, cabling, conduits & trunkings and likes for a complete installation
In addition to the auto wheel divertors, the cost of the following sub-items shall include
all the associated works mentioned in this item
i) Auto Wheel Diverters (Left and Right operation)
Supply, delivery & installation of departure baggage conveyors 2 & 3 interconnected conveyor c/w
controls, photocells, electrical, cabling, conduits & trunkings and likes for
a complete installation
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Horizontal Conveyor (Bidirectional Belt conveyor)
Supply, delivery & installation of 90 deg power curve c/w controls, photocells, electrical,
cabling, conduits & trunkings and likes for a complete installation
In addition to the power curves, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) 90 Degree Power Curve
Supply, delivery & installation of heavy duty stainless steel roller beds and likes for a
complete installation
In addition to the roller beds, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Roller Beds (3 Nos. 3 meter in length each and 3 Nos. 1 meter in length each and 4
Nos. 3 meter in length each for Cargo Scanning)

Supply, delivery, installation, testing and commissioning of fire/security doors/roller shutter and draft
curtains c/w controls, electrical, cabling, conduits & trunkings, interfacing and coordination with various
trades as specified,audible and visual warning signages, certification and likes for a complete installation
Supply, delivery & installation of 360 deg scanner (Automatic Tag Reader, ATR) c/w connection belts,
controls, photocells, electrical, cabling, conduits & trunkings and likes
for a complete installation
In addition to the 360 deg scanner, the cost of the following sub-items shall include all
the associated works mentioned in this item
i) 360 Degree Scanners

Supply, delivery, installation, testing and commissioning of ICAO & IATA Compliant ECAC-STD-3 In-line
Screening Machine with UPS, accessories and tracking system suitable for Level 1 and Level 2 security
screening of hold baggage (1800 Bags/Hr)

In addition to the scanners, the cost of the above item shall include 6 Staff Operated On- screen Resolution
(OSR) Work Stations for Level-1 rejected images complete with servers, controls, electrical power and
data cables., etc and all associated works mentioned in this item

i) L1-01
ii) L1-02
iii) L1-03 ( For Cargo Scanning)

Supply, delivery, installation, testing and commissioning of ICAO & IATA Compliant ECAC-STD-3 In-line
Screening Machine with UPS, accessories and tracking system suitable for Level 1 and Level 2 security
screening of hold baggage (1800 Bags/Hr)

In addition to the scanners, the cost of the above item shall include 6 Staff Operated On- screen Resolution
(OSR) Work Stations for Level-1 rejected images complete with servers, controls, electrical power and
data cables., etc and all associated works mentioned in this item and as per design, drawing, relavant
specification and accepted by the Engineer.

i) Dual view X-Ray Scanning Machine with UPS, STP and with necessory accessories
(Hold baggage screening)

Level-3 Staff Operated On-screen Resolution (OSR) Work Stations for the rejected images from Level-2 in
parallel to ETD System as redundancy provision complete with servers, controls, electrical power and data
cables., etc and all associated works mentioned in this item.

Supply, delivery, installation, testing and commissioning of ICAO & IATA Compliant Screening Machine for
Over-size Outbound Baggage (1000x1000 MM Tunnel Size Stand alone machine c/w UPS, associated
conveyors, S.S roller belts, operator work stations and other necessary accessories)

In addition to the scanners, the cost of the above item shall include 02 operator
workstations, servers, controls etc and all associated works mentioned in this item
Supply, delivery, installation, testing and commissioning of Explosive Trace Detection Device (ETD) with
accessories and tracking system suitable for Level 3 & 4 screening of
hold baggage
Supply, delivery, installation, testing and commissioning of Manual Encoding Equipment
with accessories and tracking system
In addition to MES, the cost of the above item shall include individual operator workstations, servers,
controls, hand held scanners, consoles, furnitures, lightings, power
point, tag printers etc and all associated works mentioned in this item

Supply, delivery, installation, testing and commissioning of emergency stop buttons c/w controls, electrical,
cabling, conduits & trunkings, interfacing and coordination with various trades as specified, audible and
visual warning signages and likes for a complete installation

Supply and installation of the electrical control panels housing the motor controls, starters, control relays,
cabling works, cable supports and motor protection relays to control and interlock the various components
of the system for proper starting and stopping of the system.
BHS Control System and Interfacing Work

Design, supply, installation, testing and commissioning of baggage control systems, Baggage Handling
System’s Virtual Local Area Network (VLAN-BHS), and equipments within and outside of the Baggage control
room., etc as listed below, but not limited to, comply with technical specification including all necessary
drawings, diagrams and supporting documents.

BHS central control system and consoles


BHS servers/racks/host/computers/gateways/ network/switches/modems
Telecommunication cablling and cable supports
PLC controllers, relays, auxillary accessories
Software Programming
Application softwares and associated licenses
User's workstations, laptops and printers
Maintenance Management Information System
Maintenance Diagnostic System
UPS (1 Hour Battery Backup)
Ground Handler Query Workstation
Equipment in Baggage Control Room
Workstations Outside the Baggage Control Room
Reporting Server Sub-system
Security and custom management computer system
Supply, installation, testing and commissioning of interfacing gateways, workstations, Hardware c/w
coordination, cabling, connections, consoles and Software programming
for the interfacing works with other airport systems.
Management Computer Sub-system
Interface to Airport Flight Information Display System
Interface to Airline Departure Control System
Interface to Airport Operations Database System
Interface to Baggage Information Display System
Interface to Common User Baggage Enterprise System
Interface to Ground Handler Query Workstation
Interface to Reporting Server Sub-system
Interface to Security and custom management computer system
Testing and Commissioning

Cost of testing and commissioning (which shall include all Airport Operation Readiness Trials) of the complete
Baggage Handling System installation including a minimum quantity of 3600 dummy baggages, all
necessary materials, equipment and labour, as required.

Miscellaneous

Design, fabrication, assembly, transportation, delivery, installation, and/or erection of the structural steel works
for the following Baggage Handling System (BHS) screening platforms and, manual encoding stations, as
per standard including all related items, appurtenances and shop coats or protective paint, complete in
every respect in strict accordance with standard Specification applicable drawings, and subject to the terms and
conditions of the Contract.

1 nos. of Manual Encoding Station Platform (including fire resistance of at least 2 hours)

4 nos. of Screening Machine Platforms

The Contractor shall supply and install maintenance power points along the length of the conveyor belt. The
work shall include but not limited to the provision of distribution boards, galvanized steel conduits,
earthings and proper mounting brackets.
To provide painting, labelling, tagging of BHS equipment as specified and likes for a
complete BHS installation
To provide audible and visual safety, warning and directional signages etc c/w controls, electrical, cabling,
conduits & trunkings, interfacing with various trades as specified and
likes for a complete BHS installation
To provide acoustic treatment to the BHS, including measurements and evaluation by
qualified person, to comply with the noise levels as specified.
To provide maintenance hoisting hook permanently beside all Security Screening Machines as specified all
& 2 sets of chain block and 2 sets of electrical and mechanical
tool for BHS for maintenance and repair.
To provide Threat Containment Vessel (TCV) c/w necessary accessories and conveyors
for connection to the BHS System as specified
CUTE SYSTEM

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the Common User Terminal Equipment System including all necessary cablings, termination and
accessories including wall, floor penetrations and re-sealed with approved fire stop material to the following :

CUTE Server with keyboard monitor, software, cabling and accessories


Fiber patch cord ( duplex) between core switches and fiber patch panel
High availability, load sharing, scalable Core Switches (Cisco 6500E equavalent) include ASA firewall
module and network management system module with accessories,
patch cables software and programming in comms room .
Interface with Airline Host Computer/Servers include programming, software, hardware
and accessories.
Interface with Local Departure Control System of Baggage Handling System include
programming, software, hardware and accessories.
Interface with Gate Management system (GMS) include programming, software,
hardware and accessories.
4 core Single Mode fiber optic link to airline host server (provision)
AOC
12 port managed Layer 2 edge switches (12 10/100 PoE port, 2 10/100/1000 PoE
ports and 2 dual purpose Gigabit SFP+ uplink ports), complete with all necessary interconnection and
accessories in AOC
Fiber patch cord (duplex) between fiber patch panel and edge switches
12 port UTP patch panel with accessories
UTP patch cord between edge switches and UTP patch panels
CAT 6 UTP cable between UTP patch panel and CUTE workstations with RJ45 face
plate (each less than 90m length)
CUTE monitoring and control workstation with software, cabling and accessories in
AOC/AFMCC room
Fibre optic converter in comms room & AOC room
8 core fiber optic link from fibre optic converter in Comms room to fibre optic converter
in AOC room (Provision)
Check-In Counter
48 port fiber patch panel with accessories
24 port stackable managed Layer 2 edge switches (24 10/100 PoE port, 2 10/100/1000 PoE
ports and 2 dual purpose Gigabit SFP+ uplink ports), complete with
all necessary interconnection and accessories.
Fiber patch cord (duplex) between fiber patch panel and edge switches
24 port UTP patch panel with accessories
UTP patch cord between edge switches and UTP patch panels
CAT 6 UTP cable between UTP patch panel and CUTE workstations with RJ45 face
plate (each less than 90m length)
CUTE workstation include software and programming and accessories
19" monitor
Baggage Tag Printer
Boarding Pass Printer
Bar Code Reader
Passport Reader (Magnetic Stripe/ Optical Character Recognition device)
general purpose/ document Printer
Self check-In Counter
CAT 6 UTP cable between UTP patch panel and CUSS workstations with RJ45 face
plate (each less than 90m length)
UTP patch cord between edge switches and UTP patch panels
CUSS workstation kiosk include software and programming and accessories
19" monitor
Baggage Tag Printer
Boarding Pass Printer
Bar Code Reader
Passport Reader (Magnetic Stripe/ Optical Character Recognition device)
Remote Management Module
Boarding Gate Counter
48 port fiber patch panel with accessories
12 port managed Layer 2 edge switches (12 10/100 PoE port, 2 10/100/1000 PoE ports and 2 dual
purpose Gigabit SFP+ uplink ports), complete with all necessary
interconnection and accessories.
Fiber patch cord (duplex) between fiber patch panel and edge switches
12 port UTP patch panel with accessories
UTP patch cord between edge switches and UTP patch panels
CAT 6 UTP cable between UTP patch panel and CUTE workstations with RJ45 Face
plate (each less than 90m length)
CUTE workstation include software and programming and accessories
19" monitor
Boarding Pass Reader
Boarding Pass Printer
Bar Code Reader
Passport Reader (Magnetic Stripe/ Optical Character Recognition device)
general purpose/ document Printer
Power point SSO including 2x 4mm2 1C PVC/PVC + 1C 4mm2 PVC E with cable support tapping from
nearest UDB located in Load Center (each csble length less than
80m)
GATE MANAGEMENT SYSTEM, FLIGHT CONTROL & AODB
Supply, installation, testing and commission with airport readiness trial of the following
equipment :
GMS and Flight Control Server with Redundancy
Supply, delivery and installation (which shall include all Airport Operation Readiness Trials) of the
following servers complete with necessary patching cards, racks and
standby UPS.

1 x database server in cluster configuration


(load balancing) – Xeon Quad Core processor @ 3 GHz - 4 GB RAM min. - 2 x Gigabit Ethernet adapter-
Redundant power supply – 2 x 500 GB hard disk - MS XP Professional operating system
1 x application server - Xeon Quad Core processor @ 3 GHz - 4 GB RAM min. - Gigabit Ethernet adapter - 2 x
500 GB hard disk - MS XP Professional operating system

Service console with 19" LCD monitor,


keyboard, mouse and KVM switch
3KVA 230V 50Hz Rack Mounted UPS for 2 hrs (min)
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
Workstations (apron control room-1nos, BHS control room -1no, AOC-1no, finance-1no,
comms equipment rooms -1no)

Supply, delivery and installation (which shall include all Airport Operation Readiness Trials) of the following
IBM PC compatible workstation complete with necessary patching cards, racks and standby UPS.

Workstation with Quad Core processor @ 2.4 GHz – 4 GB RAM – 500 GB hard disk –
Gigabit Ethernet adapter
21” LCD monitor
B/W laser printer
GMS Client license
1KVA 230V 50Hz UPS for 2 hrs (min)
Gate Management System (GMS) Software
Database software license
Application license
Customization of the GMS package
Finance module for billing

Interface and Link to the following systems:


- Airport Operation Database (AODB),
- Flight Control System (FCS),
- Building Management System (BMS)
- Common User Terminal Equipment (CUTE),
- Baggage Control System
- Flight Information Display System (FIDS)
- Airline Host Servers
- Master Clock

Application and Database software for Flight Control System (FCS)


Application and Database software for Airport Operation Database (AODB)

Supply, delivery and installation (which shall include all Airport Operation Readiness Trials) of the irport
Operation Database (AODB) enterprise servers (duty and hot standby) and software with programming
complete with necessary patching cards, racks and standby UPS.

Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) of high availability, load sharing layer 3 Core switches (equivalent to Cisco 6500E in duty and
hot standby), include ASA Firewall engine module, Network Mgt System complete with necessary
patching cords, cabling, accessories, RPS, racks and standby UPS.

Supply, delivery, installation, testing, commissioning (which shall include all Airport
Operation Readiness Trials) of signal converter, complete with necessary patching cords, cables and
accessories.
Supply, delivery, installation, testing, commissioning (which shall include all Airport
Operation Readiness Trials) of 4 core single mode fibre optic cables, complete with necessary cable
support, accessories and fiber patch panel.
CAT6 UTP distribution cables complete with cable support
Supply, delivery, installation, testing and commissioning (which shall include all Airport
Operation Readiness Trials) of 48 port fibre patch panels, complete with all necessary interconnection and
accessories in comms room
Supply, delivery, installation, testing and commissioning (which shall include all Airport
Operation Readiness Trials) of 4 port fibre patch panels, complete with all necessary interconnection and
accessories in comms room
Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Primary and Secondary
8 port RJ45 UTP Patch Panels including all necessary accessories
Hardware testing & commissioning including all airport operational trials
Hardware commissioning of all peripherals
GMS, FCS & AODB software commissioning including all airport operational trials
Software and Hardware Interconnects including cable support between servers,
distribution switches in Communication Equipment Room
Interconnects between workstations, signal converters and other peripherals
Interface with Airport Operation data base complete with cables, necessary hardware and
software data base.
Interface with Baggage Handling System complete with cables, necessary hardware and
software data base.
Interface with Flight Control Server System complete with cables, necessary hardware
and software data base.
Interface with Flight Information Display Server complete with cables, necessary
hardware and software data base.
Interface with Common User Terminal Equipment complete with cables, necessary
hardware and software data base.
Interface with Master Clock System complete with cables, necessary hardware and
software data base.

Power point SSO including 2x 4mm2 1C PVC/PVC + 1C 4mm2 PVC E with cable
support tapping from nearest UDB located in Load Center (each cable length less than 80m)

MAST LIGHTING SYSTEM

Supply, delivery, installation, testing and commissioning of the following type of Luminaires, including all
cabling works, termination, concealed GI conduit, junction box complete with quick male & female connector,
supporting brackets and necessary accessories and link to respective lighting switches on External including
Control Panel Board, Base Foundation etc for each mast pole and 01 no power tool against 02 nos mast pole etc.
all complete as per direction of the engineer.

Fixtures: LED Lamp not less than 300W x 10


Mast pole H=25M,(Up Down system)
Supply and installation of LT Cable for Mast pole:
a) 1C-4x16 mm2 NYY/2XY cable with BYA ECC wire through PVC pipe
CABLE SUPPORTTING SYSTEM
Supply, delivery, installation, testing and commissioning of the following cable tray and
trunking including all necessary suspension fixtures and accessories on Level 1
E1
i) POWER : 1x450x100mm Tray
ii) LIGHTING : 1x300mmx100 Trunking
iii) POWER : 1x300mmx100 Trunking
iv) CCTV : 1x300mmx100 Trunking
v) COMM : 3x300mmx100 Trunking
vi) FAS : 1x150mmx100 Trunking
vii) PA : 1x300mmx100 Trunking
E2
i) LIGHTING : 1x150mmx100 Trunking
ii) POWER : 1x150mmx100 Trunking
iii) CCTV : 1x150mmx100 Trunking
iv) COMM :1x150mmx100 Trunking
v) FAS : 1x150mmx100 Trunking
vi) PA : 1x300mmx100 Trunking
E6
i) ELECT : 6x700mm LADDERS
E7
i) ELECT : 2x600mm Tray
E8
i) ELECT : 2x300mm Tray
Supply, delivery, installation, testing and commissioning of the following cable tray and
trunking including all necessary accessories on Roof
G
i) ELECT : 1x300mmx100mm Trunking
Supply, delivery, installation, testing and commissioning of the following concrete
haunched UPVC pipe including all necessary accessories on the External
i) 1x110mm Dia concrete UPVC pipe
ii) 2x150mm Dia concrete UPVC pipe
iii) 4x150mm Dia concrete UPVC pipe
Underfloor Trunking
Supply, delivery, installation, testing and commissioning of the Underfloor Trunking
including wiring, fixing bracket, spike and necessary accessories on Level 1
Pre-galvanised 300mm 3-Compartment Flush Floor Trunking

300mm Junction Box c/w cover, 1 no Twin 13A powerpoints, 2 nos of RJ45 and/or RJ11

300mm Junction Box c/w cover, 1 no Twin 13A powerpoints


300mm Junction Box c/w cover

300mm Junction Box c/w cover, 25mm diameter G.I conduits linking from floor trunking junction box to ceiling
space for fire alarm detector/ bell/ FIDS/ CCTV/ speakers.

Concealed GI conduit pipe in column for speakers, linear beam detector, CCTV, FIDS,
clock, TV point
LIGHTNING PROTECTION SYSTEM
Supply, delivery, installation, testing and commissioning of the Lightning Protection System including all
necessary lightning tapes, saddles, associated casting works into
columns or building and accessories to the following :
Test Link c/w Box
Bimetallic Connector
25mm x 3.25mm HC soft annealed Cu tape (Test Link to rebar Ground Slab)
25mm x 3.25mm HC soft annealed Cu tape (Down Conductor)
25mm x 3.25mm HC soft annealed Cu tape including clamp and exothermic bond (Roof
Cu tape)
Exothermic Weld or other approved method
Bonding Roof to downconductor
Bonding downconductor from Test Link Box to Ground Slab
0.5 m high air terminal
Grounding Earth Rods including bonding, connection , accessories with resistance , 10
Ohms at each earthing point
AIRPORT SIGNAGE SYSTEM
Providing & fitting / fixing of foreign made Signage panel (Image Carrier) of light- transmitting organic
board or light box cloth rigid polyurethane foam premixed polyether polyol, i/c proper base & surface (with the
back laminated by light-resistant film) of cast vinyl graphic film (minimum 2 mil) with a clear, permanent,
pressure-sensitive adhesive and a synthetic liner that does not split if wet. The matte surface finish eliminates glare
and provides a uniform color in both reflected and transmitted light. The film is thermoformable. The
system will be completed with LED lamp, tube, professional ballast, minimum 2mm acrylic lamp panel,
minimum 5mm acrylic plate i/c wireway (For image carrier) and the following content (in both Bengali &
English) i/c direction, symbol, icon etc as necessary (in film) and as per International Standard by maintaining
proper color coding (i/c user requirement) and completed as per derection by the Engineer-in-Charge

i) For Terminal and other buildings area.


ii) For Town Side Area
iii) Airport Name Signage in Town Side and Air Side.
Sub Total (Electro-Mechanical Works)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

Set 8

Set 126

Set 1

Set 6

No 6
No 2
No 1
No 2
No 1
No 9
No 3
No 1
No 8
No 83

No 6
No 2
No 1
No 2
No 1
No 9
No 3
No 1
No 6
No 1
No 1
No 1

Set 4
Set 2
Set 5
Set 3
Set 3
Set 6

No 23

No 1
No 2

No 1

No 3

No 1

No 1

No 1

No 2

No 2
No 2
No 2
No 2

No 20
No 66
No 66
No 7

M 231

M 293

M 164

M 385

M 232

M 2402
M 837

M 119

M 770

M 179

M 242

M 514

M 61

M 287

M 987
M 61

M 96

M 8150
No 54
Bag 26

M 10512
No 70
Bag 39
m3 31

lot 1

M 7067

No 8
No 139
No 5
No 53

No 5

M 48
M 14400
M 630
No 8
No 144
No 53
No 6
M 70700

M 2000

M 33451
M 1088
M 3748
M 908
M 622
M 1403
M 2831
M 110
M 1,080
M 14,228
M 2,456
M 2,618
M 545
M 120
M 450
M 4,291
M 1,032

M 5,048

KIT 42
KIT 39
Set 4

Sets 4
Sets 4

Set 5

Set 5
Set 1

Nos. 1

Nos 1

1
1

1
1

Nos. 8
Nos. 25

Nos. 52

Nos. 20

Nos 13

Nos 2

Nos 2

Nos 2

Nos 4

Nos 2

Nos 5
Nos 2

Nos 1

Nos 1

Nos 2

Nos 2

Nos 1

Nos 5

Nos 1

Nos 1

Nos 2

Nos 1

Nos 2

Nos 3

Nos 1

Nos 2

Nos 2

Nos 3

Nos 2

Nos 3

Nos 2

Nos 1

Nos 1

Nos 1

Nos 1

Nos 2
Nos 1

Nos 3

Nos 5

Nos 2

Nos 1

Nos 2

Nos 1

Nos 1

Nos 1

Nos 4

Nos 4

Nos 2

Nos 4

Nos 1

Nos 1

Nos 2

Nos. 1

Nos. 2

Nos. 1

Nos. 1
Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 2

Nos. 1

Nos. 1

Nos. 2

Nos. 2

Nos. 2

Nos. 6

Nos 1

Nos. 2
Nos 1

Nos 2

Nos 1

Nos 2

Nos 5

Nos 1

Nos 3

Nos. 18
Nos. 1
Nos. 5
Nos. 15
Nos. 5
Nos. 5
Nos. 10
Nos. 5
Nos. 25
Nos. 90

Nos. 10
Nos. 16
Nos. 16
Nos. 4
Nos. 4
Nos. 4
Nos. 2
Nos. 2

Nos. 10
Nos. 4
Nos. 10
Nos. 10

Nos. 10
Nos. 16
Nos. 16
Nos. 4
Nos. 4
Nos. 4
Nos. 2
Nos. 2

Nos. 6
Nos. 2

Nos. 4
Nos. 16
Nos. 20
Nos. 6
Nos. 36

Nos. 16
Nos. 16
Nos. 4
Nos. 4
Nos. 4
Nos. 2
Nos. 2

Nos. 20
Nos. 85

Nos. 40
Nos. 2
Nos. 2
Nos. 3
Nos. 3

Nos. 50

Nos. 4
Nos. 24
Nos. 4
Nos. 3

Nos. 4
Nos. 40
Nos. 16
Nos. 4
Set 1

Set 1

Each 1
Each 1
Set 1

Nos. 1330
Nos. 405

Nos. 310
Nos. 100
Nos. 45
Nos. 75
Nos. 15
Nos. 65
Nos. 155

Nos. 46
Nos. 30
Nos. 34
Nos. 20
Nos. 30
Nos. 22
Nos. 2
Nos. 4
Nos. 56
Nos. 4
Nos. 40
Nos. 40

Nos. 5
Nos. 1
Nos. 2
Nos. 1
Nos. 1
Nos. 11
Nos. 5
Nos. 1
Nos. 1
Nos. 3
2
1
Nos. 5
Nos. 1
Nos. 4

Sq. ft. 100390


Sq. ft. 100390
Sq. ft. 139520
Sq. ft. 391340

Sq. ft. 120000

Nos. 365

Rft 350
Nos. 285
Nos. 140
Nos. 120
Nos. 85
Nos. 70
Nos. 50

Meter 480
Meter 2,800
Meter 50
Meter 600
Meter 3,900
Meter 200
Meter 40
Meter 220
Meter 300
Meter 40
Meter 110
Meter 190
Meter 120
Meter 265
Meter 320
Meter 450
Meter 40

Meter 1670
Meter 1270
Meter 1225
Meter 1025
Meter 625
Meter 650
Meter 1655
Meter 1025
Kg. 180
Lot 1
Lot 1
meter 70
meter 1,180
meter 260
meter 550
meter 1,752

meter 70
meter 1,180
meter 260
meter 550
meter 1,752

Nos 97
Nos 97

Nos. 1

Nos. 1
Job 1

Job 1
Nos. 8

Nos. 1

Nos. 3
Nos. 3

No 2
No 2

No 2
Set 2
Set 1

M 54
M 24
M 7.2

No 6

M 6

No 3

Set 6

lot 1

lot 1
Set 36

Set 36

M 24
M 18
M 24

M 90
M 13.2
M 20
M 2.4

No 5

M 1

No 6

M 24

Set 6
Set 3

No 1
No 1
No 1

No 1

Set 3

No 1

Set 3

Set 1

Lot 1

Lot 1
Lot 1

Lot 1

Lot 1

Lot 1

No 30
Lot 1

lots 1
nos 19

nos 2

lot 1

lot 1

lot 1

m 1,000

no 1

no 2
no 1
no 2

no 2

no 2

nos 2

m 1,500

nos 1

nos 3

nos 6
nos 3
nos 36
nos 36

nos 36
nos 36
nos 36
nos 36
nos 36
nos 36
nos 6

no 2

nos 2
no 2
no 2
no 2
no 2
no 2
no 2
no 2

no 1

no 2

no 4
no 2
nos 8

no 8

no 4
no 4
no 4
no 4
no 4
no 4
nos 4

lot 1
lot 1

lot 5

lot 1

lot 1
lot 1

lot 1

no 1

no 2

lot 1

lot 1
no 1

no 10

no 1

lot 1
lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

No 20

M 2000

M 100
M 100
M 50
M 60
M 100
M 50
M 50
M 100
M 100
M 50
M 100
M 50
M 60

M 20

M 100

M 100

M 100

M 100
M 100
M 150

M 200

Nos 20

Nos 32
Nos 75

Nos 65

Nos 100

No 40
No 40
M 2,000
M 2,000

M 4,000

No 40
No 40
No 100

No 100
Sqm 380
Sqm 200
Sqm 360
Item No.

6
o Navigational Aid System
onnection with Existing ILS/DME

6.1.1.1

6.1.1.2

6.1.1.3
6.1.1.4
6.1.1.5

6.1.1.6

Part 6.1: Radio Navigational Aid System


6.1.2 DVOR
6.1.2.1
6.1.2.2
6.1.2.3
6.1.2.4
6.1.2.5
6.1.2.6
6.1.2.7

6.1.2.8

6.1.2.9
6.1.2.10

o Navigational Aid System


6.1.3 Facilities for ATS Communication

6.1.3.1
6.1.3.2

6.1.3.3

6.1.3.4
6.1.3.5
6.1.3.6

6.1.3.7
6.1.3.8

6.1.3.9

6.1.3.10
6.1.3.11

6.1.3.12

6.1.3.13

6.1.3.14

6.1.3.15

6.1.3.16
6.1.3.17
6.1.3.18

6.1.3.19
6.1.3.19

6.1.3.20

6.1.3.21
6.1.3.22
6.1.3.23
6.1.3.22
6.1.3.23
6.1.3.24

6.1.3.25

6.1.3.26

6.1.3.27
6.1.3.28

g Communication Equipments
6.2.1

6.2.1.1
6.2.1.2

6.2.1.3
6.2.1.4

6.2.1.5

6.2.1.6

6.2.1.7

6.2.1.8

6.2.1.9
6.2.1.10

6.2.1.11

6.2.1.12

6.2.1.13
6.2.1.14

6.2.2

6.2.2.1

6.2.2.2

6.2.2.3

6.2.2.4

6.2.2.5

6.2.2.6
6.2.2.7
6.2.2.8
6.2.2.9

6.2.2.10

6.2.2.11

6.2.2.12

6.2.2.13

6.2.2.14

6.2.2.15

6.2.2.16

6.2.3

6.2.3.1
6.2.3.2
6.2.3.3
6.2.3.4
6.2.3.5

6.2.3.6
6.2.3.7
6.2.3.8
6.2.3.9

6.2.3.10
6.2.3.11
6.2.3.12

6.2.3.13
6.2.3.14

6.2.3.15
6.2.3.16
6.2.3.17
6.2.3.18
6.2.3.19
6.2.3.20
6.2.3.21
6.2.3.22
6.2.3.23
6.2.3.24
6.2.3.25
6.2.3.26
6.2.3.27
6.2.3.28
6.2.3.29

6.2.4

6.2.4.1
6.2.4.2
6.2.4.3

6.2.4.4

6.2.4.5
6.2.4.6
6.2.4.7
6.2.4.8
6.2.4.9
6.2.4.10
6.2.4.11
6.2.4.12

6.2.4.13

6.2.4.14

6.2.4.15

6.2.4.16

6.2.4.17

6.2.4.18
6.2.4.19
6.2.4.20
6.2.4.21

6.2.4.23
6.2.4.24
6.2.4.25
6.2.4.26
6.2.4.27
6.2.4.28
6.2.4.29

6.2.4.30

6.2.4.31

6.2.4.32

6.2.4.33

6.2.4.34

6.2.4.35
6.2.4.36
6.2.4.37
6.2.4.38

6.2.5

6.2.5.1
6.2.5.2
6.2.5.3

6.2.5.4
6.2.5.5
6.2.5.6
6.2.5.7
6.2.5.8

6.2.6

6.2.6.1

6.2.6.2
6.2.6.3

6.2.6.4

6.2.6.5

6.2.6.6

6.2.6.7

6.2.6.8

6.2.6.9

6.2.6.10

6.2.6.11

6.2.6.12

Part 6.3: Security Equipments


6.3.1

6.3.1.1

6.3.1.2
6.3.1.3
6.3.1.4

6.3.2

6.3.2.1
6.3.2.2

6.3.3

6.3.3.1
6.3.3.2
6.3.3.3
6.3.3.4

6.3.3.5

6.3.3.6
6.3.3.7
6.3.3.8
Description of Item

Communication & Security Equipments


avigational Aid System
nection with Existing ILS/DME

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments including all necessary accessories, power cable, required civil and
electro-mechanical works etc. as per design, drawing, relavant specification and accepted by the Engineer.

RCSU, 1Station, 1RSU included RMM


- RMT Status Unit
- RCSU System
Fiber Optic Transmitting Unit included Radio Link
- 11 Localizer (Integrated Equipment Room to LOC Shelter)
- 11 GP/DME (Integrated Equipment Room to GP/DME Shelter)
RCSU and RSU Installation include accessories
Final Tune, Test and Flight Check Ground Support
Remote Control Cable , each Fiber Optic 6C, only material
- 11 Localizer (Integrated Equipment Room to LOC Shelter), 3682m
- 11 GS/DME (Integrated Equipment Room to GS/DME Shelter), 2075m
Remote Control Cable Installation for ILS/DME

t 6.1: Radio Navigational Aid System


2 DVOR
Supply of Dual DVOR 100 watt with co-located DME with shelter, antenna,
counterpoise complete with air-conditioning, wiring etc (as per specification)
Supply of Dual DME (as per specification)
Supply of RMMU & RSU including remote control cable (fiber optic )
Supply of spare parts for DVOR
Supply of spare parts for DME
Supply of Test equipment
Installation, Testing & Commissioning
Necessary E/M works at site under supervision by the Engineer – in – charge of the
concern E/M Division of CAAB

Necessary Civil works at per Drawing and Design (by manufacturer) at site under
supervision by the Engineer – in – charge of concern Civil Division of CAAB
Radio Earthing for item no 1 to 2(as per drawing & instruction of Engineer – in – charge)

avigational Aid System


3 Facilities for ATS Communication

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments including all necessary accessories, power cable, required civil and
electro-mechanical works etc. as per design, drawing, relavant specification and accepted by the Engineer.

VHF RADIO
VHF TX RADIO
- VHF Transmitter(50W, single), 10Set
- VHF cavity filter, 5Set
- VHF isolator, 5Set
- Standard Rack
- Main/Standby Changeover Unit, 5Set
- Other sub-assemblies (Cable and Others)
VHF RX RADIO
- VHF Receiver, 10Set
- Standard Rack
- Main/Standby Changeover Unit, 5Set
- Other sub-assemblies
VHF ANT
- VHF TX ANT & Assembly, 5Set
- Lighting surge arrestor of VHF TX ANT, 5Set
- VHF RX ANT & Assembly, 5Set
- Lighting surge arrestor of VHF RX ANT, 5Set
UPS-10kVA (included BATT.) (int the TX Station) (Back up time: 60minutes)
Portable Type VHF/UHF Multi-CH Transceiver ((in the ATCT and IECR)
SPARE PARTS
- Transmitter (50w)
- Receiver
- VHF cavity filter(dual)
- VHF isolator
- VHF TX ANT (included lightining surge arrestor)
- VHF RX ANT (included lightining surge arrestor)
- Main/Standby Changeover Unit
- Cavity filter
Packing and Transportation (CIP)
VHF RADIO Installation
VCCS
STVS
- Central Equipment & Interfaces_TED(6+2SP), Radio(5), Phone(40)
- Controller Working Positions, 6POS (ATCT Room-4, IECR-1, TX Room-1)
- Voice Communication Management System
- Other sub-assemblies (Cable and Others) including IDF
Recorder/Replay, 50ch dual
Digital Clock System with GPS ANT, Master-1, Slave-4
AMHS
- Server (Integrated Equipment Control Room-1)
- AMHS Terminal (ATCT Room-1, Weather Obs. Room-1, AMHS/Comm Room-3)
- AMHS RCMS (IECR-1)
UPS (included BATT.)
- 10kVA, in the Control Tower Room, 1Set (Back up time: 60mnts min.)
- 20kVA, in the Integrated Equipment Control Room, 1Set (Back up time: 60mnts)
Spare Parts
Test Equipment and Tools
- Communicaton Service Monitor
- Attenuator
- RF Power level meter
- VSWR tester
- Line level meter
Technician's tool
Packing and Transportation (CIP)
Flight Check Ground Support
ATIS
Main System
- Voice Synthesis Control System
- Voice Synthesis Processing System
- Remote Control Management System
- ATIS Terminal (Control Tower Room-1)
- ATIS Display Monitor (Control Tower Room-1)
- ATIS RCMS (IECR-1)
- HUB
- Modem
- Surge Protector
- Printer
- Voice Program
- Control Equipment Prom
- MIC
- Accessories (included 19" Rack)
Spare Parts
- Voice Synthesis Control System
- Voice Synthesis Processing System
- Voice Program
Packing and Transportation (CIP)
ATIS Installation
Datal Cable , UTP CAT.5-25PrX4, only material
- Integrated Equipment Control Room to Control Tower Room, 45m
Data Cable Installation
Remote Control Cable , Fiber Optic 6C, only material
- TX Station (Integrated Equipment Control Room to TX Station), 2155m
Remote Control Cable Installation for TX Station
Cable Tray, Aluminium w300xh150xt2.0mm
- Integrated Equipment Control Room, 35m
- Control Tower Room, 7m
- Roof Floor in the ATCT, 60m
- TX Equipment Control Room, 10m
- Roof Floor in the Fire Station, 23m
Console (Wood+Steel), only material
- Control Tower Room (H1068xW2100xD960)X4sets
- Integrated Equipment Control Room (H710xW3600xD1000)X1set
- TX Equipment Room (H710xW2400xD1000)X1set
Console Installation
Existing Facilities Demolition
- Control Console, Recorder, ANT and Rack included accessories

ommunication Equipments
FLIGHT INFORMATION DISPLAY SYSTEM
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of FIDS system including all necessary accessories, power cable, required
civil and electro-mechanical works (if any) etc. as per design, drawing, relavant specification and accepted by the
Engineer.
FIDS server with all required sofrware in main and hot standby configuration including
network printer as attached specification.
Data input terminal (DIT) with all required softwate as per specification.
Monitor 42 inch LED/TFT arrivel display monitor with embedded controller and necessory accessories to
install at different arrival area (out side and different floor) of
terminal building as per specification.
Monitor 55 inch LED/TFT Departure display monitor with embedded controller and necessory accessories
to install at different departure area. of terminal building as per
specification.

Monitor 42 inch LED/TFT Departure display monitor with embedded controller and necessory accessories
to install at different departure area. of terminal building as per
specification.

Baggage belt display Monitor 42 inch LED/TFT with embedded controller and necessory accessories to install at
different baggage area. of terminal building as per specification..

Checking counter display Monitor 32 inch LED/TFT with embedded controller and necessory accessories
to install at different checking area. of terminal building as per
specification.

Stuff monitor 22 inch LED/TFT including controller with numeric key pad. Stuff monitor should be program to
display deperture arrival and metrological information in different
pages.
Maitenance terminal with all accessories and required software as per specification.
Supply of minimum 6 core fiber optic cable, cat-6 cable and other necessary accessories
to complete whole connectivity of the system (as required).
Supply of Data switch (8/16/24 port), media converter, Tx Rx and etc to complete whole
connectivity and run of the system (as required).
10 KVA UPS with necessary accesoories for back power of main system and all Display
unit for uninteruppted operation of the system.
System match Electric power cable (standard rating), Circuit breaker, electric switch,
extension board and etc to provide electric power for whole system to run.
Standard table and chair (wooden made) for DIT.
SUB TOTAL

PABX
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of PABX system including all necessary accessories, power cable, required
civil and electro-mechanical works (if any) etc. as per design, drawing, relavant specification and accepted by the
Engineer.

Supply of PABX Call Server with redundancy (N+1) as per attached specification. Configuration:
IP Extension: 50
Analogue Extension: 50. Analogue Trunk line : 20 nos. E1 (ISDN PRI): 01.
Unified Messaging 32 Port Mailbox. 50
Call details recording (CDR) & Call Billing Software.

Supply, installation and configuration of media Gateway, switch and other related
modules for all nodes/unit as per requirement to successfully complete the project on turn key basis.

Supply installation and configuration of Analogue subscriber card for 50 nos. Analogue
Extension (as per attached specification).
Supply, installation and configuration of Trunk card for 20 nos. (as per attached
specification).
Supply, installation and configuration of E1 (ISDN PRI) card (as per attached
specification).
Supply installation and configuration of PC Based operator console with necessary
accessories (as per attached specification ).
Supply of IP Telephone Set (as per attached specification).
Supply of Analogue Telephone Set (as per attached specification ).
Supply installation and configuration of O&M Terminal (PC) with all necessary
accessories including standard network printer (as per attached specification).
Supply , installation and configure of Voice logger system with all necessary accessories
for call recording (as per attached specification).
Supply and installation of MDF& IDF with required Krone steeper as per requirement to successfully complete
the project on turn key basis. (as per attached specification).
Supply and installation of Earthing system with all accessories for Server unit, PC base
operator console, and O&M Terminal (PC) (as per attached specification ).
Supply and Installation of Charging unit (1+1) and Backup power system with maintenance free
Battery for Server unit, PC base operator console, and O&M
Terminal (PC).
Supply and installation of 04 pair Cable for IP phone connection in house (Terminal Building) as per
attached specification with direction of Engineer in charge.
Supply and installation of drop wire (01 pair, 0.9 mm) cable for Analogue extension/ phone connection
outdoor of Terminal Building as per direction of Engineer in charge.

Supply of all other accessories and equipment base furniture to install , fitting fixing
and programming of whole system as per requirement to successfully complete the project (from user end
to Call server) on turn key basis.

SUB TOTAL

Two Way Communication System:

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Two Way Communication System system including all necessary
accessories, power cable, required civil and electro-mechanical works (if any) etc. as per design, drawing,
relavant specification and accepted by the Engineer.

VHF Repeater system


VHF Repeater system (main and standby configaration) including change-over unit and
necessary accessaries as per attached specification.
Separate Tx/Rx Antenna for VHF Reapeter System
Antenna feeder cable conectors including installation kits
Tx/Rx Antenna Mast 40 feet
3 KVA online UPS with necessary power cable (as required) as power backup for
Repeater System.
VHF Walkie-Talkie
VHF Walkie-Talkie set with antenna belt clip, min 2200 mAh Lithiam-Ion battery
charger with adapter
6-Pocket multi charger unit
Spare battery min 2200 mAh Lithiam-Ion
Programming kits with necessary software including programming PC Core-i7, 1 T
HDD, 8 GB RAM etc.
VHF Transceiver
VHF Transceiver including micophone and other accessories as per attached
specification
VHF Transceiver Antenna, feeder cable, conectors including installation kits
Programming kits with necessary software including user and maintenace maunal
VHF Receiver Pannel
VHF Receiver as per attached specification
VHF Receiver Antenna, feeder cable, conectors including installation kits
DATIS Recorder and replay Unit
Standard DATIS Recorder and replay Unit
VHF Transmeter for DATIS including antenna as per attached specifiation
Digital Conference System
Central Control System Unit as per attached specification
Chairman Unit with Gooseneck microphone and head phone as per attached specification
Delegate Unit with Gooseneck microphone and head phone as per attached specification
Wireless Hand Held Microphone with recured accessories
Mixer Power Amplifier
20W Column Speaker with Stand
Compatible rack for Central Control Unit, Amplifier, etc.
3 KVA Online UPS, Backup time: 15 minutes (Minimum) on full load.
PC based recording system with required recording software as per specificaton.
Necessary accessories: Power extension board, Cable, Cable Tie, channel pipes, etc.
Standard Computer chair & table
Multimedia Projector with Motorized screen
Laptop Core-i7, 1 T HDD, 12 GB RAM etc

PUBLIC ADDRESS SYSTEM

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Public Address system including all necessary accessories, power
cable, required civil and electro-mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

In Comm. Equipment room


Fully Digital Audio Matrix & Central Processor Network Controller
FM/AM tunner complete with interconnecting cables and power supply
Multi disc DVD player and PC based MP3 player (main/stand by config) complete with
interconnecting cables and power supply
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
In AOC Level 1
Control monitoring PC with configuration/ diagnostic & logging software (in AOC)
6 Watt ceiling recessed/ surfaced mounted speaker
20 Watt horn speaker
6 Watt box speaker
60 Watt line array speaker
Basic Call Station (1channel) complete with cabling and accessories
Standard Call Station (10 channels) complete with cabling and accessories
Master Call Station (60 channels) complete with cabling and accessories for AOC and
FCC
60 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
125 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
250 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt fail safe auto change over redundant power amplifier complete with line
supervision set, Network Controller, interconnecting cables and power supply
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
Ambient Noise Sensors with controller for all passenger access area
4 Core Fire Rated (FR) Fibre Optic Cable with accessories and termination
Wiring with 2C x 14 AWG standard Fire Rated copper flexible wire including 1" dia GI conduit for music system
complete in all respects as per drawings and specifications.
In AOC Level 2
6 Watt ceiling recessed/ surfaced mounted speaker
20 Watt horn speaker
6 Watt box speaker
60 Watt line array speaker
Basic Call Station (1channel) complete with cabling and accessories
Standard Call Station (10 channels) complete with cabling and accessories
Master Call Station (60 channels) complete with cabling and accessories for AOC and
FCC
60 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
125 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
250 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt fail safe auto change over redundant power amplifier complete with line
supervision set, Network Controller, interconnecting cables and power supply
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
Ambient Noise Sensors with controller for all passenger access area
4 Core Fire Rated (FR) Fibre Optic Cable with accessories and termination
Wiring with 2C x 14 AWG standard Fire Rated copper flexible wire including 1" dia GI conduit for music system
complete in all respects as per drawings and specifications.

CLOCK SYSTEM
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Clock system including all necessary accessories, power cable, required
civil and electro-mechanical works (if any) etc. as per design, drawing, relavant specification and accepted by the
Engineer.
Network Time Protocol Master clock system complete with software programming
(Duty and Standby)
Single sided digital clock
Design, supply, installation of all necessary accessories, supporting frames, C Channels, brackets for a complete
supporting system for clock in compliance with specification
Supply and installation of CAT 6 UTP cable from UTP Patch Panel located in ELV riser
to Clock point (The cable for each point should not exceed more than 90m.)
Signal Amplifiers for GPS signal on Roof
GPS antenna complete with lightning surge protection including bonding to earth
GPS receiver module with necessary interconnecting cables, cable support and rack
RG11 GPS antenna cables complete with cable support

STRUCTURE CABLING SYSTEM


Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of 2x24 core singlemode armoured fibre optic cable from fibre patch
panels in Comms room1 and Comm Rm 2
Supply, delivery, installation, testing and commissioning (which shall include all Airport
Operation Readiness Trials) of 2x24 port fibre patch panels, complete with all necessary interconnection
and accessories Comms Rm
Supply, delivery, installation, testing and commissioning of of Mass Cable Transit System (MCT) for
Telecommunication cables entry, inclusive of all associated accessories and building works necessary to
provide the complete system as specified and complying with relevant codes in the Terminal Building.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of 48 port stackable managed Layer 2 edge switches (48 10/100 PoE+ port, 2 10/100/1000 PoE ports
and 2 dual purpose Gigabit SFP+ uplink ports), complete with all necessary interconnection and accessories.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of 24 port stackable managed Layer 2 edge switches (24 10/100 PoE+ port, 2 10/100/1000 PoE ports
and 2 dual purpose Gigabit SFP+ uplink ports), complete with all necessary interconnection and accessories.

Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Primary and Secondary 48 port RJ45 Data/Voice UTP Patch Panels
including all necessary accessories
Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Primary and Secondary 24 port RJ45 Data/Voice UTP Patch Panels
including all necessary accessories
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Data Outlet (RJ45) including back box and all necessary
accessories as per drawings and specification

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Voice/ Tel Outlet (RJ45) including back box and all
necessary accessories as per drawings and specification

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of IP telephone set.
Data point consist of CAT 6 UTP Voice/Data cable and conduit from riser UTP patch
panel to Outlet point (each does not exceed 90m)
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of UTP patch cord
between edge switches and UTP patch panel (Data/ Voice Panel) in the riser
t 6.3: Security Equipments
Security Screening Equipment

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Security Screening system including all necessary accessories, power
cable, required civil and electro-mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Dual view X-Ray Scanning Machine with UPS, STP and necessory accessories (Cabine
baggage screening)
Dual view X-Ray Scanning Machine with UPS, STP and with necessory accessories (
Hold baggage screening)
Walk-Through Metal Detector with necessory accessories.
Hand Held Metal Detector

Under Vehicle Scanning System and Barrier Gate.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Under Vehicle Scanning System including all necessary accessories,
power cable, required civil and electro- mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Under Vehicle Scanning System (UVSS)


Barrier Gate with RFID Card Reader for Vehicle

CCTV Camera Survelliance System:

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of CCTV Camera Survelliance System including all necessary accessories,
power cable, required civil and electro- mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Minimum 16 channel NVR (Network video recorder) with 42 inch LED monitor as per
specification.
Fixed (out door and indoor) IP IR camera as per specification.
PTZ (out door and indoor) IP IR camera as per specification.
Workstation with computer table and Off line 600 VA UPS (Back up time 30 mintes) as
per specification.
Optical fiber cable (06 core, 12 core), data cable (cat06 ) to comple connectivity of all
cameras inside and outside of terminal building. (as required)
10 KVA online Central UPS with necessary power cable (as required) for power
connectivity to all cameras inside and out side of terminal building.
IP switch as required and Compitible with system
Standerd size rack for containing of NVR
with minitor 42 inch.
Sub-Total (Communication and Security System)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

LOT 1

LOT 1

LOT 1
LOT 1
m 5,757

JOB 1

SET 1
SET 1
SET 1
SET 1
LOT 1
LOT 1
JOB 1

JOB 1

JOB 1
JOB 1

LOT 1
LOT 1

LOT 1

SET 1
SET 2
LOT 1

LOT 1
LOT 1

LOT 1

LOT 1
LOT 1
LOT 1

SET 2

LOT 1
LOT 1

LOT 1
LOT 1
LOT 1

LOT 1
LOT 1

LOT 1
LOT 1
m 45

LOT 1
m 2,155

LOT 1
m 135

SET 6

SET 6
JOB 1
-

nos. 2
nos. 4

nos. 20
nos. 4

nos. 35

nos. 6

nos. 8

nos. 10

nos. 2
lot 1

lot 1

nos. 2

job 1
set 5

set 1

lot 1

lot 1

lot 1

job 1

no. 1
nos. 50
nos. 50
no. 1

no. 1

job 1

job 1

job 1

job 1

lot 1

job 1

nos. 2
nos. 4
set 4
nos. 4
nos. 1

nos. 50
nos. 4
nos. 25
set 1

set 4
set 4
set 4

nos. 4
set 4

nos. 2
nos. 2
nos. 2
nos. 2
nos. 30
nos. 2
nos. 1
nos. 2
nos. 1
nos. 1
nos. 1
lot 1
Set
set 1
nos. 1

Lot 1
No 1
No 1

No 2

No 1
Nos 100
Nos 20
Nos 10
Nos 15
Nos 2
Nos 2
Nos 1

Nos 2

Nos 2

Nos 5

Nos 4

Nos 16

Nos 1
Nos 30
m 500
m 800

Nos 80
Nos 15
Nos 10
Nos 4
Nos 4
Nos 2
Nos 2

Nos 5

Nos 5

Nos 5

Nos 24

Nos 16

Nos 8
Nos 30
m 500
m 800

nos 2
nos 20
nos 20

nos 20
nos 2
nos 2
nos 2
lot 1

lot 2

no 2
lot 1

no 4

no 8

no 4

no 8

nos 50

nos 50

nos 50

nos 100

nos 100

nos. 12

nos. 12
nos. 24
nos. 55

Set 2
Set 2

nos. 15
nos. 150
nos. 30
nos. 10

lot 1

lot 1
job 1
nos. 5
Item No.

7
7.1

7.1.1

7.1.2

7.1.3

7.1.4

7.1.5

7.1.6
7.1.7
7.1.8
7.1.9

7.1.10
7.1.11
7.1.12
7.1.13

7.1.14

7.1.15
7.1.16
7.1.17

7.1.18

7.1.19

7.1.20

7.1.21
7.2
7.3
Description of Item

Construction of Fuel Hydrant Pipe line


JET A-1 Hydrant System

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments for JET A-1 Hydrant System including all necessary accessories, power
cable, required civil and electro-mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Hydrant Pipeline Work with Internally Epoxy paint coated 40 Schedule Pipes (Seamless)
a) 10inch Diameter,Sch40 Seamless ASTEM A53 Gr.A Internal Epoxy Coated, External
Polyethlen lining
c) 6 inch Diameter, Sch 40 Seamless or API 5L Grade B Seamless PE COATED
d) 2 inch Diameter, PIPE, CS A106-B PE COATED SMLS BE B36.10M, S-80
Barred Tee /Reducer
a) Reducer Barred Tee (10 inch X 6 inch), TEE,CS 234 WPB SMLS BE
B16.9IMPACT TEST S-40 PE COATED
b) Barred Tee 10" x10" Equal Tee TEE,CS 234 WPB SMLS BE B16.9IMPACT TEST
S-40 S-40 PE COATED
c) Reducer (6 inch X 4 inch) Sch 40 x Sch 40 Seamless API 5L Grade B Seamless PE
COATED

Bends Sch 40
a) 10 inch Diameter 5D Bend Cold Bend 90 Deg ch 40 Seamless API 5L Grade B
Seamless PE COATED
b) 6 inch Diameter 5D Bend Cold Bend 90 Deg ch 40 Seamless API 5L Grade B
Seamless PE COATED
c) 6 inch Diameter 90 DEG ELL LR, CS A234-WPB-SMLS BE B16.9, S-40
Flanges:
a) 10 inch Diameter ND Flange: WNRF Class 150 A105 ANSI B16.5 for welding with
Pipe, Sch 40 Seamless or API 5L Grade B Seamless
b) 6 inch Diameter ND Flange: WNRF Class 150 A105 ANSI B16.5 for welding with
Pipe, Sch 40 Seamless or API 5L Grade B Seamless
c) 2 inch Diameter ND Flange: WNRF Class 150 A105 ANSI B16.5 for welding with
Pipe, Sch 40 Seamless or API 5L Grade B Seamless
Cast Steel Gate Valves:
a) 10 inch Diameter Gate Valve RF Class 150 ANSI B16.5
Emergency shut off stations
Aviation Grade Hose Couplings (2.5" dia)
Aviation Grade Hose Pipe with Couplings (2.5" dia, 20'-0" long)
Low point sump including valve (intermediate drain pit) Sampling unit for Vent or Drain
unit Including 20" pit and safety block valve
Hydrant Pit Valve #300 API 1584 3rd Edition Including 20"hydrant pit and safety block
valve
Distant Relay set
14" inch casing pipe Sch 40 Seamless or API 5L Grade B Seamless PE COATED
Providing pipe line coating/wrapping materials in/c. supplying of at as per standard
specification.

Providing cathodic protection including supply of materials for Cathodic Protection


works with Conductivity Survey and Test Result (3 Sets) as per standard Specification and Practice.

Line Cleaning & Drying PIG


a) 10 " Foam PIG
b) 6" Foam PIG
c) 10" Cup PIG
d) 6" Cup Pig
6" X 2" Weld-o-let,WELDOLET CS A105 BE/SW MSS-SP-97 IMPACT TEST S-40
X S-80
END CAP
6" End CAP,CS 234 WPB-SMLS BE B16.9M S-40
Blind Flange
a) 10" ND Blind Flanges : WNRF Class 150 A105 ANSI B16.5
Gasket: RF Class 150 for fitting in above Flanges
a) 10" GASKET 316 SS WND GRAPH FILL 316 SS 1/R CS O/R RF B16.20 CL150
4.5MM THK( 3.2 MM RING) SPR WND
Stud Bolt C/W 2HEX. Nuts A193 Gr. B7 /A194 Gr. 2H
a) 1 x 5 1/4"- Dia and LG should allow fitting in above 10" Valve & 10" Flange C/W
2HEX. Nuts A193 Gr. B7 /A194 Gr. 2H
Jet A1 Standard Turbine Flow Meter
Radiographic Testing of the whole hydrant system in/c. submission of report in 3 sets.
Testing, commissioning and obtaining a certificate from one of oil majors/preferable
Shell.
Sub-Total (Fuel Hydrant System)

Grand-Total
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

Meter 2100.00
Meter 1300.00
Meter 300.00

Nos. 40.00

Nos. 3.00

Nos. 26.00

Nos. 25.00

Nos. 25.00
Nos. 7.00

Nos. 20.00

Nos. 5.00

Nos. 8.00

Nos. 9.00
Nos. 3.00
Nos. 10.00
Nos. 10.00
Nos. 8.00

Nos. 30.00
Nos. 1.00
Meter 400.00
Job 1.00

Job 1.00

Nos. 18.00
Nos. 6.00
Nos. 6.00
Nos. 2.00
Nos. 12.00

Nos. 8.00

Nos. 1.00

Nos. 50.00

Nos. 648.00
Nos. 1.00
Job 1.00
Job 1.00
1 Preliminary and General Items 一般项 1 Preliminary and General Items 一般项
2 Land Development Works 土地开发 3.1 Foundation Works 房建基础(桩基)
3.1 Foundation Works 房建基础(桩基) 3.2 Super-structure Works 土建结构
3.2 Super-structure Works 土建结构
A. 航站楼及附属建筑物及临建的土建工程(含装修装 3.2.3 Steel Structure Works 钢结构
饰工程)
3.2.3 Steel Structure Works 钢结构 3.3 Finishing Works 饰面装修
3.3 Finishing Works 饰面装修 3.4 Furniture 家具
3.4 Furniture 家具 3.7.4 SEWAGE TREATMENT PLANT 污水处理厂
3.5 Fire Fighting System 消防系统 B. 飞行区场道(机坪、垂直联络道、快滑道及排水工 2 Land Development Works 土地开发
3.6 Plumbing and Sanitary Works 给排水 程)+各类停车场+各类道路工程 4 Civil Works
跑道及停机坪
3.7.1 Internal Electrification Works 内部电力系统(弱电) 3.5 Fire Fighting System 消防系统
3.7.2 Electrical Substation works 电站(强电) 3.6 Plumbing and Sanitary Works 给排水
ADDRESSABLE FIRE DETECTION &
3.7.3 火警系统 3.7.1 Internal Electrification Works 内部电力系统(弱电)
ALARM SYSTEM
3.7.4 SEWAGE TREATMENT PLANT 污水处理厂 3.7.2 Electrical Substation works 电站(强电)
ADDRESSABLE FIRE DETECTION & ALARM
4 Civil Works 跑道及停机坪 3.7.3 火警系统
C. 机电设备采购及安装工程(航站楼内及其他附属物 SYSTEM
5.1 Airfield Ground Lighting ( AGL ) System 助航灯光 5.2 HVAC SYSTEM 高压交流电系统
5.2 HVAC SYSTEM
的机电安装) 5.3.1 ELEVATOR & ESCALATOR
高压交流电系统 电梯及扶梯
5.3 MECHANICAL EQUIPMENTS 5.3.2 PASSENGER BOARDING BRIDGE 登机桥
5.3.1 ELEVATOR & ESCALATOR 电梯及扶梯 5.3.3 BAGGAGE HANDLING SYSTEM 行李系统
5.3.2 PASSENGER BOARDING BRIDGE 登机桥 5.3.5 GATE MANAGEMENT SYSTEM, FLIGHT 门禁系统
5.3.3 BAGGAGE HANDLING SYSTEM 行李系统 5.3.6 CONTROL
MAST LIGHTING& AODB SYSTEM 桅灯系统
5.3.4 CUTE SYSTEM 通讯终端设备系统 5.3.7 CABLE SUPPORTTING SYSTEM 电缆系统
5.3.5 GATE MANAGEMENT SYSTEM, FLIGHT 5.1 Airfield Ground Lighting ( AGL ) System
CONTROL & AODB 门禁系统 助航灯光
5.3.6 MAST LIGHTING SYSTEM 桅灯系统 5.3.4 CUTE SYSTEM 通讯终端设备系统
5.3.7 CABLE SUPPORTTING SYSTEM 电缆系统
D. 助航灯光及空管工程设备采购及安装(包含通信导 5.3.8 LIGHTNING PROTECTION SYSTEM 避雷系统
航航管气象)
5.3.8 LIGHTNING PROTECTION SYSTEM 5.3.9 AIRPORT SIGNAGE SYSTEM
避雷系统 机场标识系统
5.3.9 AIRPORT SIGNAGE SYSTEM 机场标识系统 6 Communication & Security Equipments 通讯及安检设备
6 Communication & Security Equipments 7 Construction of Fuel Hydrant Pipe line
E. 机坪供油工程
通讯及安检设备 燃油供应管线
7 Construction of Fuel Hydrant Pipe line
燃油供应管线
Expansion of Osmani International Airp

Item No.

1
1

1.1

1.2

1.3

1.4

N.B.: The Cost of all other items that are to be carried out under section: 7 and 8 of Tender document but no
of Work.
3
3.1
3.1.1

3.1.1.1

3.1.1.2
3.1.1.3

3.1.2

3.1.2.1

3.1.2.2

3.1.2.3

3.1.3

3.1.3.1

3.2
3.2.1

3.2.1.1

3.2.1.2

3.2.1.3
3.2.1.4

3.2.1.5

3.2.2

3.2.2.1
3.2.2.2

3.2.2.3

3.2.2.4

3.2.2.5

3.2.2.6

3.2.2.7

3.2.2.8

3.2.3

3.2.3.1
3.2.3.2

3.2.3.3

3.2.3.4

3.2.3.5

3.2.3.6

3.2.3.7

3.2.3.8

3.2.3.9

3.3

3.3.1

3.3.2
3.3.3

3.3.4

3.3.5

3.3.6

3.3.7

3.3.8

3.3.9

3.3.10

3.3.11

3.3.12

3.3.13
3.3.14

3.3.15

3.3.16

3.3.17

3.3.18

3.3.19

3.3.20

3.3.21

3.3.22
3.3.23

3.3.24

3.3.25

3.3.26

3.3.27

3.3.28

3.3.29

3.3.30

3.3.31

3.3.32
3.3.33

3.4
3.4.1

3.4.2

3.4.3

3.4.4

3.4.5

3.4.6

3.4.7

3.4.8

3.4.9

3.4.10

3.4.11

3.4.12

3.4.13

3.4.14

3.4.15

3.4.16
Expansion of Osmani International Airport, Sylhet

Description of Item

2
Preliminary and General Items

Provision for living accommodation (1200 sq.m) for the Employer, the Engineer and their staff in/cl
furnishings the accommodation, supply of house hold, equipment’s and utensils, maintenance of
accommodation, supply of furniture, fittings, fixtures, and consumable materials etc. all complete as per
detailed description of the relevant specification and direction of the Engineer in charge.

Providing of furniture and field office equipment and maintenance of field Office including furniture,
fixtures, Equipment and supply of consumables etc. all complete and as per instruction of the Engineer. And
provision for security and their maintenance etc. all complete as per detailed description of the relevant
specification and direction of the Engineer in charge.

Construction of Contractors site office (400 Sq.-m), Consultant site office (400 Sq.-m) and Field Laboratory
building (400 Sq.-m) including toilet, fittings, utilities, services and development of surrounding area,
providing of laboratory testing equipment’s, and provision of staffs for maintenance of laboratory building,
equipment and furniture with all supplies, consumables etc. all complete as per detailed description of the
relevant specification and direction of the Engineer in charge.

Provide vehicles (in good running condition for 24 hours) on rental basis for the Employer, Engineer and
their staffs having Jeep 4 Nos @ 33 months each, 4 door Pick- up 1 No. @ 33 months each, and Microbus
(Noah/Voxy or equivalent type with auto door opening system)4 Nos @ 33 Months, each shall
include fuel, servicing, maintenance, driver, drivers wages, taxes, duties, registration, insurance etc.all complete
as per detailed description of the relevant specification and direction of the Engineer in charge. as applicable.

a) Jeep
b) Microbus
c) Pick-up
Sub-Total (Preliminary and General Items)

B.: The Cost of all other items that are to be carried out under section: 7 and 8 of Tender document but not included as
Work.
Building Works
Foundation Works
Pile Works

Construction of cast-in-situ pile by Auger Boring/ Rotary Drilling up to the required depth and diameter
with reinforced cement concrete of Class 25, carrying the spoils / mud accumulated during boring by
truck or any other means within Airport area, disposal and compaction, everything complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer. (Rate is excluding
the cost of reinforcement and its fabrication).

Breaking head of cast in situ bored Service pile/precast pile up to required length by any means and carrying the
dismantled materials by truck or any other means within Airport area including loading and unloading at both
ends, disposal and compaction as per specification of relavant chapter and accepted by the Engineer.
Conducting static load test as per ASTM D1143 or equivalent standard for the cast-in- situ/pre-cast pile providing
required scaffolding, bracing, jacks, pressure test gauge, loading unloading, Kentledge and other plants
and equipment including staging, mobilization, demobilization, hire charge, gunny bags, sand and filling
sacs/gunny bags for loading, record readings and preparation of results in standard forms and other
incidental charges as per standard practice and procedures including submission of load test report, furnishing all
graph and chart etc. complete in all respect as per specification of relavant chapter and accepted by the Engineer.

a) For 200 tonne load on test pile


b) For 150 tonne load for on Service pile
Pile Cap, short column and grade beam

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
below cement concrete, reinforced concrete slab etc. all complete as per detailed description of the relevant
specification and direction of the Engineer in charge.

Construction of Lean Concrete in foundation or in floor, Composed of aggregates, Portland cement, water
and approved additives in conformity with the lines, grades, etc. including cost of formwork all complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Reinforced cement concrete (Class 32) works using steel shutter with minimum cement content relates to mix
design having minimum f'cr = 40 Mpa, and satisfying a specified compressive strength f’c = 32 Mpa including
cost of formwork etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication).

a) Individual & Combind footing, Pile Cap, raft/mat.


b) In short column, lift wall, retaining wall etc.
c) In grade beam
Reinforcement

Supplying, carrying and fabrication of Grade 60 ribbed or deformed bar complying BDS ISO 6935-2:2006,
produced and marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 414
MPa but fy not exceeding 450 MPa and whatever is the yield strength within allowable limit as per BNBC/
ACI 318, the ratio of ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum
elongation after fracture and minimum total elongation at maximum force is 16% and 8% respectively. All
complete as per detailed description of the relevant specification and direction of the Engineer in charge.

Super-structure Works
RCC Floor Slab, Column, Beam etc.

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
below cement concrete, reinforced concrete slab etc. all complete as per detailed description of the relevant
specification and direction of the Engineer in charge.

Construction of Lean Concrete in foundation or in floor, Composed of aggregates, Portland cement, water
and approved additives in conformity with the lines, grades, etc. including cost of formwork all complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Reinforced cement concrete (Class 32) works using steel shutter with minimum cement content relates to mix
design having minimum f'cr = 40 Mpa, and satisfying a specified compressive strength f’c = 32 Mpa including
cost of formwork etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication).
a) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at
ground floor
b) In Column, Column Capital, Lift wall, Walls etc. at ground floor
c) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 1st
floor
d) In Column, Column Capital, Lift wall, Walls etc. at 1st floor
e) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 2nd
floor
f) In Column, Column Capital, Lift wall, Walls etc. at 2nd floor
g) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 3rd
floor
h) In Column, Column Capital, Lift wall, Walls etc. at 3rd floor
i) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 4th
floor
j) In Column, Column Capital, Lift wall, Walls etc. at 4th floor
k) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 5th
floor
l) In Column, Column Capital, Lift wall, Walls etc. at 5th floor
m) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 6th
floor
n) In Column, Column Capital, Lift wall, Walls etc. at 6th floor
o) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 7th
floor
p) In Column, Column Capital, Lift wall, Walls etc. at 7th floor
q) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 8th
floor
r) In Column, Column Capital, Lift wall, Walls etc. at 8th floor
s) In floor slab, stair case slab and steps, T-Beam, L-Beam, rectangular beam etc. at 9th
floor
t) In Column, Column Capital, Lift wall, Walls etc. at 9th floor

Cast-in-place fair-faced concrete works with f'cr=30 Mpa and f'c=25 Mpa at 28 days on standard cylinders by
using 75% of OPC and 25% of white cement conforming to BDS EN-197-1-CEM-I, 52.5N (52.5 MPa) / ASTM-C
150 Type – I, best quality Sylhet sand or coarse sand of equivalent F.M. 2.5, 20 mm down and well graded crushed
stone chips conforming to ASTM C-33 including cost of formwork etc. all complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer. (Rate is excluding the cost of reinforcement
and its fabrication).

For column, wall, beam, slab, drop wall, cornice etc. up to ground floor

Supplying, carrying and fabrication of Grade 60 ribbed or deformed bar complying BDS ISO 6935-2:2006,
produced and marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 414
MPa but fy not exceeding 450 MPa and whatever is the yield strength within allowable limit as per BNBC/
ACI 318, the ratio of ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum
elongation after fracture and minimum total elongation at maximum force is 16% and 8% respectively. All
complete as per detailed description of the relevant specification and direction of the Engineer in charge.

Brick wall, plaster works, patent stone, water proofing etc.

Brick works with first class bricks with cement sand (F.M. 1.2) mortar (1:4) in exterior walls including filling the
interstices with mortar, raking out joints, cleaning and socking the bricks at least for 24 hours before use and
washing of sand, necessary scaffolding, curing at least for 7 days etc. all complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

a) In ground floor
b) In 1st floor
c) In 2nd floor

Providing 125 mm thick brick work in superstructure (partition walls) with cement sand (F.M. 1.2) mortar
(1:4) with 10 hole machine made ceramic bricks of approved size having uniform colour, carefully laid in
cement mortar of uniform width & depth of joints, true to vertical and horizontal lines including racking out
joints, filling the interstices with same mortar, making bond with connected walls, cleaning, soaking brick at
least 24 hours and washing of sand, curing 7 days etc. all complete as per design, drawing, specification
of relavant chapter and accepted by the Engineer.

a) In ground floor
b) In 1st floor
c) In 2nd floor
Water-proofing membrane (Foreign made) on made up surface below the floor or below the horizontal surfaces
with temporary protective cover using polysterene/38 mm thick sand-cement mortar in 4:1 /or by equally
effective alternative all complete as per detailed description of the relevant specification and direction of the
Engineer.
Water-proofing membrane (Foreign made) on vertical or inclined wall /on plastered and
primed back-wall and concrete cast against membrane all complete as per detailed description of the
relevant specification and direction of the Engineer.

Minimum 12 mm thick cement sand (F.M. 1.2) plaster with neat cement finishing to plinth wall (1:4)
with cement up to 150 mm below ground level with neat cement finishing including washing of sand,
finishing the edges and corners and curing at least for 7 days, cost of water, electricity and other charges etc. all
complete as per detailed description of the relevant specification and direction of the Engineer.

Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:4) with fresh cement to ceiling
R.C.C. columns, beams, surface of stair case, sunshades, cornices, railings, drop wall, louvers, fins and
finishing the corners and edges including washing of sand cleaning the surface, scaffolding and curing at least
for 7 days, cost of water, electricity and other charges etc. all complete as per detailed description of the
relevant specification and direction of the Engineer.
(Cement: CEM-II/A-M)

38 mm thick artificial patent stone (1:1.5:3) flooring with cement, best quality coarse sand minimum F.M. 2.2
and 12 mm down well graded stone chips, laying the concrete in alternate panels, compacting and finishing the
top with neat cement and curing at least for 7 days in all floors including cost of water, electricity and other
charges etc. all complete as per detailed description of the relevant specification and direction of the
Engineer.

Water proofing work on roof top surface with 2 layer 2.5 mm STP felt, 50 mm stylo foam, 75 mm thick
screed concrete with 8 mm dia MS rod, joint filling with sutable compound etc. all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Steel Structure Works

Supply, fabrication and installation of foreign made hot-rolled sections (W, H, I-shape, Channel, angle etc.) for
columns, beams, rafters, bracings etc. conforming to BS EN 1993, BS EN 10025 or BS EN10210 Grade
S345 steel or ASTM 242/242M Grade 50 with minimum yield strength of 345N/mm2 (50 ksi), and Structural
hollow sections shall be of hot rolled sections complying with BS EN 10210 Grade 50 with minimum yield
strength of 345N/mm2 (50 ksi).including the cost of testing of plates, application of red/grey-oxide primer
etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.
Supply and installation of galvanized decking panel according to ASTM A653, with minimum yield
strength of 345 MPa, including all necessry accessories (sheeting screws with washers, sealants etc.), testing of
materials etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply and installation of foreign made GI purlin & girt of any size conforming to "ASTM A653" grade
45, with a minimum yield strength of 310 MPa, including the cost of testing of materials, all complete as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply and fixing of connection bolts of variable diameter with nut and washer according to "ASTM
A325 Type 1 or equivalent” with Fu =720 Mpa, including the cost of testing of bolts, all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing foreign made Colour Bonded Zinc Alum sheet as per specification, RC
Roofing with necessary Insulation, Flashing and Capping, fitted and fixed with all necessary including 'J'
hook purlin with screws, limpet washers and putty etc. all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supply, Fiiting fixing of Rigid Insulation (Polyurethane Foam) as per as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
Providing Intumescent Fireproofing Paint coat applying to structural steel truss member etc. all complete as per
design, drawing, specification of relavant chapter and accepted
by the Engineer.

S.F & F (Foreign made) Heat Reflected foil made with duble providers resistance to heat transfer and top &
bottom cover by pure Aluminium foil facing Airspace in/c fitting, fixing the same by 20 mesh 24 BWG wire
mesh etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Suppply, fitting & fixing of Oriented Strand Board (2ply) Foreign Made: Work Should be done as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Finishing Works

Engineered Granite stone flooring (Forign made) (Minimum 25 mm thick) of any size and approved quality,
texture (Mirror polished top surface) over designed thickness of cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the marble stone to desired size, grinding and
finishing the edges, setting in position in proper level filling the gaps with white cement and colouring
pigments including supplying all necessary equipments/materials and finishing the top by pumic stone and
necessary auxiliary materials and water, electricity and other charges complete in all respect as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
(Cement: CEM-II/A-M)

Engineered Granite stone flooring (Forign made) (Minimum 25 mm thick) of any size and approved quality,
texture (Mat polished top surface) over designed thickness of cement sand (F.M. 1.2) mortar (1:2)
including. placing cement slurry below the stone, cutting the marble stone to desired size, grinding and
finishing the edges, setting in position in proper level filling the gaps with white cement and colouring
pigments including supplying all necessary equipments/materials and finishing the top by pumic stone and
necessary auxiliary materials and water, electricity and other charges complete in all respect as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
(Cement: CEM-II/A-M)
Supply fitting fixing of Vinyl tiles (Forign made) of any size and approved quality in floor irrespective of
color & /or design, with quality acrylic dispersion glue, cement sand (F.M 1.2) mortar (1:4) base and raking out
the joints with cement including cutting and laying the tiles in proper way and finishing with care etc. all
complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply fitting fixing of Porcelain tiles (Forign made) of any size and approved quality in floor with irrespective
of color & /or design, with cement sand (F.M 1.2) mortar (1:4) base and raking out the joints with cement
including cutting and laying the tiles in proper way and finishing with care etc. all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supply fitting fixing of Ceramic wall tiles (Forign made) of any size and approved quality in floor with
irrespective of color & /or design, with cement sand (F.M 1.2) mortar (1:4) base and raking out the joints
with cement including cutting and laying the tiles in proper way and finishing with care etc. all complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of high quality Rubber Studded floor tiles (Forign made) of any size and approved
quality in floor, irrespective of color & /or design, with adhesives in full thickness of tiles, filler/tiles grout in/c
cutting, shaping, placing in proper level etc. all complete as per design, drawing, specification of relavant chapter
and accepted by the Engineer.

Construction of hardenered floor with stone chips, coarse sand, metal chips, cement etc. as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of 9 mm thick perforated gypsum board false ceiling, framing by
aluminium T-bar of natural anodized finish suspended in 600 mm x 600 mm grid from ceiling by 12 SWG double
ply wire, fixed to the ceiling by rowel plug, screws, hooks, nails etc., maintaining straight lines and desired
finished level at bottom face including vertical wooden strut as required, making holes in slabs or beams by
electric drill machine and mending good the damages, if any during execution of the work all complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of aluminium false ceiling (Hunter Douglas or equivalent) of any size, shape, color
and design suspended from the ceiling with necessary framing arrangement etc. all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of decorative false ceiling and walling for VIP hall, corridor and toilet area as per
design, drawing, specification of relavant chapter and accepted by
the Engineer.

Epoxy enamel paint of approved quality and colour delivered from authorized local agent of the
manufacturer in a sealed container; surface preparation including cleaning, drying, making free from dirt etc.
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Premium synthetic enamel paint of approved best quality and colour delivered from authorized local
agent of the manufacturer(Berger robbialac supergloss synthetic enamel/Elite lucky seven/ Asian apcolipe
premium paint or equivalent brand) in a sealed container, having high water resistance, high bondibility,
flexiblity property; using specified brand thinner applying to metallic or wooden surface by brass/roller/spray
in two coats over single coat anti-corrosive coating including cleaning, drying, making free from dirt, grease,
wax, removing all chalked and scaled materials, all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Providing weather coating of approved quality and colour delivered from authorized local agent of the
manufacturer in a sealed container; surface preparation including cleaning, drying, making free from dirt
etc. as per design, drawing, specification of relavant chapter and accepted by the Engineer.
Providing acrylic emulsion paint of approved quality and colour delivered from authorized local
agent of the manufacturer in a sealed container; surface preparation including cleaning, drying, making
free from dirt etc. as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of Foreign made heavy duty glass partition made of 10 mm low-E tempered glass +
12 mm air space + 5 mm clear tempered glass + 1.14 PVB + 5 mm clear tempered glass, fixed with heavy
duty aluminum section and all necessary accessories etc. all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing foreign made 10 mm thick clear tempered glass partition with heavy duty
stainless steel frame including all necessary arrangement and accessories as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Supplying, fitting and fixing 10 mm thick clear tempered glass partition with heavy duty aluminum frame
including all necessary arrangement and accessories as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing for aluminium curtain wall 200X150X6X9mm thik. I-Beam For Vertical
Frame. Supplying, Fabricating, Fitting and Fixing of 6mm+1.52PVB+5mm+12A+6mm
Double Low-E Teampared Laminated Insulated Glass. Powder Coated aluminum alloy profile, Materials
6063-T5. 2.5mm AP, adopted foreign brand for Capping the I- Beam Section. Later Embedding,
Galvanized Steel. Sealant: Weather Proof Silicon Sealant- Type S, Grade NS, Class 50 Use NT, A, G, M,
O. Minimum Joint Movement Capability ±50%.Structural Silicone Sealant- Type M, Use G and O. Elongation
300% all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing of foreign made heavy duty 12 mm thick clear tempered glass Automatic
sliding doors with sensor system as per design, drawing, specification
of relavant chapter and accepted by the Engineer.
Supplying, fitting and fixing foreign made 10 mm thick clear tempered single/double leaf glass door including all
accessories 2 set maintenance auto closed special quality 4 nos clamping device, 1 set locking device, top
hinge and handle etc. All complete as per design, drawing, specification of relavant chapter and accepted by
the Engineer.
Supplying, fitting and fixing foreign made double/single leaf Complete Door made of metal shutter &
metal frame including door lock and all accessories finished with Electro
powder coating as per approved design and accepted by the Engineer.

Supplying, fabrication and Installation of foreign made (Minimum 5 mm thick) Aluminium


composite panel (Alucobond/Alcopanel/Alpolic) with multiple color combination approved by the
Engineer as per US Architectural Aluminium Manufacturer's Association (AAMA) in column, beam and
wall surface providing heavy duty aluminum section including supply of necessary hardwares,
consumables, scaffolding etc fitted with necessary accessories like rivet, screw, rowel bolt etc. all complete
in all respect as per as per design, drawing, specification of relavant chapter and accepted by the Engineer.
Supplying fitting and fixing of aluminium fixed louver as per the U.S. Architectural Aluminium
Manufacturer‟s Association (AAMA) standard specification and BDS 1879:2014 having 1.2mm thick
wall frame (size 76.20 mm, 38.10 mm, 0.707 kg/m), 5 mm thick louver section (size 55.02 mm, 37.39 mm,
0.22 kg/m) and 2.50 mm thick louver outer section (size 39.67 mm, 15.06 mm, 0.265 kg/m) and inner
inclined aluminium louver section fixed with above mentioned frame and all aluminium members (total weight
7.992 kg) will be anodized to aluminium bronze/silver/ss/black colour with a coat not less than 15 micrones in
thickness or powder coated to any colour with a coat not less than 25 micrones in thickness and density of 4 mg
per square cm etc including all accessories, neoprene, sealant, nuts and bolts etc. complete in all respect as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
Powder coated to any colour.

Making of ACCESS Floor made of Anti static UPVC which will be fixed over SS Frame fitted and fixed
in floor.The raise of floor will be 200mm. All fitting and fixing as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying, fitting and fixing Aluminium door frames, windows, partitions and curtain wall including
distortion free glass (6 mm thick) of designed thickness of approved quality and shade including cost of
fitting fixing all necessary accessories etc. complete in all respect as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying, fitting and fixing 10 mm thick tempered glass railing with 62 mm dia 3 mm thick SS pipe for hand
rail, 62 mm x 50 mm x 3 mm vertical box fitted with concrete slab by 85 mm x 85 mm x 8 mm SS plate @ 600
mm c/c including all fittings, fixtures etc. all complete in all respect as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Providing decorative metal nosing to the nose of tread of stair including fitting and fixing all complete
as per design, drawing, specification of relavant chapter and accepted
by the Engineer.

Supplying, fitting and fixing of rolling shutter of any design and shape made of 24 SWG
G.P. sheet unit minimum 69 mm width having 10 mm and 12 mm dia circular folding at ends, rolled in machine,
locked together properly to form rolling shutter, top of the shutter to be fitted with circular spring box
made of 22 BWG sheet, containing best quality spring made etc. complete in all respect as per design,
drawing, specification of relavant chapter and accepted by the Engineer.

Construction of column guard with reinforced cement concrete and heavy duty MS angle, plate etc. all complete
as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying, fitting & fixing of Protector made of 62mm dia SS Pipe fittinng and fixing as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

Supplying, fitting and fixing 12 mm thick burma teak (BT) veneered board in walling with best quality and
well seasoned garjan wood frame of section 75 mm x 38 mm at 600 x 600 mm in grid, fitted and fixed to wall by
plugs, nails, screws etc. including treatment of inner surface with termite and damp proofing agent maintaining
leveled and finished exposed faces including. making holes in wall and mending good the damages, if any
during execution of the work, also including cost and carriage of all materials, electricity, accessories, labour for
installation, scaffolding, screws, nails etc. including french polishing by 3 coats over a coat of priming
etc. all complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Supply Fitting fixing of 18 mm thick foreign made SDF board partation wall and door provided with best quality
items towel, soket, bolt, screws, round lock etc.approved by as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
Supplying fitting and fixing fixed skylight with 50 mm thick double toughend / acrylic glass, Argon gas filled in
gap and laminated the inner glass panes for added safty, fitted in Aluminium frame and fixing in roof truss
with Neoprene gaskit, as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Furniture
Supply and placing of Foreign made 3 seater lounge chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supply and placing of Foreign made 2 seater lounge chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supplying and placing of foreign made international standard Tension queu Belt including post as per
design, drawing, specification of relavant chapter and accepted by
the Engineer.
Supplying and placing of foreign made international standard Immigration counter set (2 person per counter) as
per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying and placing of foreign made international standard custom and security desks as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

Supplying and placing of foreign made international standard Baggage Troley as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

Supplying, fitting, fixing and placing of foreign made best quality complete set of furniture for VIP
Lounges as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

Supplying and placing of Full Sectariate table as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supplying and placing of Half Sectariate table as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supplying and placing of staff table as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying and placing of Full Sectariate Revolving Chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supplying and placing of Half Sectariate Revolving Chair as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Supplying and placing of Staff Chair as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
Supplying and placing of Visitor's Chair as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying and placing of Book Shelf as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Supplying and placing of File Cabinet as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
rnational Airport, Sylhet (1st Phase)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5.00 6=5 7=4x5 8=7

Two Hundred And Eighty


month 33.00 12,000.00
Thousand

Two Hundred And Eighty


sum 1.00 50,000.00
Thousand

Two Hundred And Eighty


sum 1.00 280,000.00
Thousand

Two Hundred And Eighty


month 132.00 3,000.00 Thousand
Two Hundred And Eighty
month 132.00 2,600.00 Thousand
Two Hundred And Eighty
month 33.00 2,400.00 Thousand

document but not included as a pay item in BOQ shall be deemed to be included with the other items

Cum 26002.35 620.00

Cum 866.75 25.00


No 29.00 40,000.00
No 29.00 30,000.00

Sqm 5900.00 2.00

Cum 442.50 135.00

Cum 7237.50 189.75


Cum 6140.10 189.75
Cum 3950.00 189.75

Ton 6802.80 1,056.85

Sqm 43630.00 2.50

Cum 3272.25 189.75


Cum 16099.00 189.75
Cum 3908.00 189.75
Cum 860.00 189.75
Cum 1486.00 189.75
Cum 2160.00 189.75
Cum 1486.00 189.75
Cum 250.00 189.75
Cum 566.00 189.75
Cum 20.00 189.75
Cum 120.00 189.75
Cum 20.00 189.75
Cum 120.00 189.75
Cum 30.00 189.75
Cum 120.00 189.75
Cum 30.00 189.75
Cum 240.00 189.75
Cum 40.00 189.75
Cum 120.00 189.75
Cum 40.00 189.75
Cum 120.00 189.75

cum 95.00 178.25

Ton 4081.84 1,056.85

Cum 19239.00 13,924.65


Cum 2335.00
Cum 2555.00

Sqm 1776.00
Sqm 435.00
Sqm 526.00

Sqm 46960.00

Sqm 17319.00

Sqm 120675.00

Sqm 96979.00

Sqm 5829.00

Sqm 8247.00

kg 12485000.00 2,400.00
kg 538837.00

kg 431836.00

kg 1650348.00

Sqm 48080.00 220.00

Sqm 48080.00

Sqm 48080.00 20.00

Sqm 35840.00

Sqm 48080.00

Sqm 23105.00

Sqm 3780.00
Sqm 6997.00

Sqm 2472.00

Sqm 4608.00

Sqm 654.00

Cum 1546.00

Sqm 13723.00

Sqm 26500.00

Sqm 6255.00

Sqm 7760.00 74.63

Sqm 3420.00 89.55

Sqm 26570.00
Sqm 114200.00

Sqm 14645.00

Sqm 1372.00

Sqm 538.00

Sqm 701.00

Sqm 75.00

Sqm 344.00

Sqm 521.00

Sqm 19320.00
Sqm 3967.00

Sqm 481.00

Sqm 1897.00

Sqm 392.00

Rm 2091.00

Sqm 483.00

Nos. 110.00

Rm 9845.00

Sqm 1070.00

Sqm 1964.00
Sqm 3150.00

Set 800.00

Set 80.00

No 350.00

Set 24.00

Set 45.00

Set 600.00

Set 1.00

No. 25.00

No. 50.00

No. 95.00

No. 25.00

No. 50.00

No. 92.00

No. 188.00

No. 75.00

No. 150.00
620.0593408 175.22877

0.2826 3.5385704
29750
Item No.

2.1

2.2

2.3

2.4

2.5

2.6

2.7

2.8

2.9

2.10

4
4.1: Construction of Apron, Taxiway & Shoulder
4.1.1

4.1.2

4.1.3
4.1.4

4.1.5

4.1.6

4.1.7

4.1.8

4.1.9

4.1.10

4.1.11

4.1.12

4.1.13

4.2: Construction of Road, Carpark & Foothpath

4.2.1

4.2.2

4.2.3
4.2.4

4.2.5
4.2.6

4.2.7

4.2.8

4.3: Construction of Drainage System

4.3.1

4.3.2

4.3.3

4.3.4

4.3.5

4.3.6

4.3.7

4.3.8

4.3.9
4.3.9

4.3.8

4.4: Water Supply and Sewerage System

4.4.1

4.4.1

4.4.2

4.4.3
4.4.4

4.4.5

4.4.6

4.4.7

4.4.8

4.4.9
4.4.10

4..4.11

4.4.12
4.4.13

4.4.14

4.4.15

4.4.16

4.4.17

4.4.18

4.4.19
4.4.19

4.4.20

4.4.21

4.4.21

4.5
4.5.1
4.5.1.1
4.5.1.2
4.5.1.3
4.5.1.4
4.5.1.5

4.5.2

4.5.3

4.5.3.1

4.5.3.2

4.5.3.3

4.5.3.4
4.5.3.5

4.5.4

4.5.4.1

4.5.4.2

4.5.4.3

4.5.4.4

4.5.4.5

4.5.4.6

4.5.5

4.5.6

4.5.7
Description of Item

Land Development Works

Demolition of existing Asphalt Pavement of any thickness manually or mechanically, carrying the material
by track or any other means within Airport area including loading and unloading at both ends, disposal and
compaction as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Demolition of existing concrete Pavement of any thickness manually or mechanically, carrying the material
by track or any other means within Airport area including loading and unloading at both ends, disposal and
compactionas per design, drawing, specification of relavant chapter and accepted by the Engineer.

Demolition of existing interlocking block of any thickness manually or mechanically , carrying the material
by track or any other means within Airport area including loading and unloading at both ends, disposal and
compaction as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Demolition of existing brick wall of any thickness manually or mechanically, carrying the material by track or
any other means within Airport area including loading and unloading at both ends, disposal and compaction
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Earth work in excavation of any thickness in all kinds of soil for pavement or any other structure, carrying the
material by track or any other means within Airport area including loading and unloading at both ends,
disposal and compaction as per specification of relavant chapter and accepted by the Engineer.

Construction of Sand Compaction Pile of 200 mm dia. by tripod, hammer, winch machine, providing
temporary steel casing pipe of 200 mm dia of required length using coarse sand of F.M. not less than 2.5 with
proper compaction all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer.

Sand filling where required with suitable sand having minimum F.M. 1.5 with all lead and lift including
leveling, watering and compaction to achieve density not less than 98% in top 600 mm and 95% in rest of
the filling depth of maximum dry density as determined by the ASTM D-1557 by ramming each layer
up to finished level as per design, drawing, specification of relavant chapter and accepted by the
Engineer. Compacted thikness of each layer shall not be more than 150mm.

Lime treatment work for soil modification to achieve required strength to a specific level by constructing one or
more courses of a mixture of soil, lime, and water in accordance with the design, drawing, specification of relavant
chapter and accepted by the Engineer.

Seeding: This item shall consist of soil preparation, including fertile soil, seeding the areas in accordance
with the design, drawing, specification of relavant chapter and
accepted by the Engineer.
Sodding: This item shall consist of furnishing, hauling, including fertile soil and placing approved live sod on
prepared areas in accordance with the design, drawing,
specification of relavant chapter and accepted by the Engineer.
Sub-Total (Land Development Works)

Civil Works
Construction of Apron, Taxiway & Shoulder
Construction of crushed aggregate sub-base course in/cl transport of materials from approved quarry,
crushing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-154)
Construction of crushed aggregate base course in/cl transport of materials from approved quarry, crushing,
laying, compaction etc. as per design, drawing, specification of
relavant chapter and accepted by the Engineer. (FAA; P-209)
Supply and provide Bituminous material Prime coat. (FAA; P-602)
Supply and provide Bituminous material Tack coat (FAA; P-603)
Construction of asphalt concrete base course in/cl transport of aggregates, import of bitumen, mixing,
laying, compaction etc. as per design, drawing, specification of relavant
chapter and accepted by the Engineer. (FAA; P-403)
Construction of asphalt concrete surface/wearing course in/cl transport of aggregates, import of bitumen,
mixing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-401)

Construction of Lean Mix Concrete Composed of aggregates, Portland cement , water and approved additives on
a prepared sub-grade in conformity with the lines, grades in/c. using concrete pump machine as per design,
drawing, specification of relavant chapter and accepted by the Engineer. (FAA; P-306)

Construction of pavement quality concrete (PQC) slab composed of aggregates, Portland cement, water and
approved additive on L.M.C base in conformity with the lines, grades in/c. using concrete pump machine as
per design, drawing, specification of relavant chapter and accepted by the Engineer. (FAA; P-501)

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
or any where below cement concrete complete in all respect and
accepted by Engineer-in-charge.
S.F&F of dowel bar cage with 1/2" dia (60 grade) M.S rod to proper size including
painting with anticorrosive paint etc. as per design, drawing, specification of relavant chapter and accepted
by the Engineer.
Supplying fitting fixing 40 mm dia 510 mm long (Foreign made) Fusteel or equivalent brand Epoxy coated M.S
plain round dowel bar as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

Supply and laying 2 mm thick Geo-textile of approved quality and origin/manufacturer as per manufacturer’s
instructions approved and accepted by the Engineer. Before commencing laying of Geo-textile, the
Contractor must submit the method statement for carrying out this work including sample with evidence of
origin and compliance certificate from independent testing laboratory for approval.

Joint filling with joint sealing compound as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Construction of Road, Carpark & Foothpath
Construction of crushed aggregate sub-base course in/cl transport of materials from approved quarry,
crushing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-154)
Construction of crushed aggregate base course in/cl transport of materials from approved quarry, crushing,
laying, compaction etc. as per design, drawing, specification of
relavant chapter and accepted by the Engineer. (FAA; P-209)
Supply and provide Bituminous material Prime coat. (FAA; P-602)
Supply and provide Bituminous material Tack coat (FAA; P-603)
Construction of asphalt concrete base course in/cl transport of aggregates, import of bitumen, mixing,
laying, compaction etc. as per design, drawing, specification of relavant
chapter and accepted by the Engineer. (FAA; P-403)
Construction of asphalt concrete surface/wearing course in/cl transport of aggregates,
import of bitumen, mixing, laying, compaction etc. as per design, drawing, specification of relavant chapter and
accepted by the Engineer. (FAA; P-401)
Supplying and placing of 60 mm thick coloured uni-block for paving foot-path, major walk way, car
porch having compressive strength of 49 N/mm2 on compacted sand bed of 50 mm on stabilized soil base, and
filling all interstices with sand, cleaning etc. as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying, carrying, placing, providing of 100 mm thick concrete Kerb stone as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
Construction of Drainage System
Construction of crushed aggregate sub-base course in/cl. transport of materials from approved quarry,
crushing, laying, compaction etc. as per design, drawing, specification
of relavant chapter and accepted by the Engineer. (FAA; P-154)
Construction of aggregate base course in/cl transport of materials from approved quarry, crushing, laying,
compaction etc. as per design, drawing, specification of relavant chapter
and accepted by the Engineer. (FAA; P-209)

Construction of Lean Concrete Composed of aggregates, Portland cement, water and approved additives
on a prepared sub-grade in conformity with the lines, grades in/c. using concrete pump machine,
formwork etc. as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Reinforced cement concrete (Class 32) works using steel shutter with minimum cement content relates to mix
design having minimum f'cr = 40 Mpa, and satisfying a specified compressive strength f’c = 32 Mpa including
formwork etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer. (Rate is excluding the cost of reinforcement and its fabrication).

Supplying, carrying and fabrication of Grade 60 ribbed or deformed bar complying BDS ISO 6935-2:2006,
produced and marked according to Bangladesh standard, with minimum yield strength, fy (ReH)= 414
MPa but fy not exceeding 450 MPa and whatever is the yield strength within allowable limit as per BNBC/
ACI 318, the ratio of ultimate tensile strength fu to yield strength fy, shall be at least 1.25 and minimum
elongation after fracture and minimum total elongation at maximum force is 16% and 8% respectively. All
complete as per detailed description of the relevant specification and direction of the Engineer in charge.

Supplying and laying of single layer polythene sheet weighing one kilogram per 6.5 square meter in floor
or any where below cement concrete complete in all respect and
accepted by Engineer-in-charge.

Minimum 6 mm thick cement sand (F.M. 1.2) plaster (1:3) with fresh cement to concrete surface and finishing
the corners and edges including washing of sand, cleaning the surface, curing at least for 7 days, cost of
water, electricity, scaffolding and other charges etc. all complete in all respect as per drawing and accepted by the
Engineer-in-charge. (Cement: CEM-II/A-M)

Surface Drain with CC (1:1.5:3) with ussed stone chips Construction of R.C.C Surface drain size (2m +1.61m X
o.98) earth excavation in trenches 150 mm sand filling single layer polythene laying & single layer Brick flat
soling and 0.30 m depth 1.61 m wide Bottom slab and 68 m hight 0.23m Thick side wall R.C.C (1:1.5:3)
with 1.5% Reinforcement with steel shutter and 150 mm dia P.V.C pipe 6.0 m lond 6.0 m interval as requipment
with 6 mm thick NCF Cement sand (FM.1.2) Plaster etc all complete approve and accepted drawing by the
Engineer in Charge.

Supply fitting fixing of Reinforced concrete pipe, perforted Pipe & PVC Pipe as per
relevent speciication , drawings and accepted by the Engineer.
a) Reinforced Concrete pipe- D1200 mm
b) Reinforced Concrete pipe- D1500 mm
c) Reinforced Concrete pipe- D2000 mm
d) Reinforced Concrete pipe- D 600 mm
e) PVC pipe- D 200mm
f) Perforated pipe- D150mm
g) PVC pipe- D 150mm
Lining of drain with one layer brick flat soling with first class/picked jhama bricks, filling the joints with cement
sand mortar including preparation of bed, compaction, leveling
etc. complete and accepted by the Engineer.
Water Supply and Sewerage System

Supplying, fitting and fixing different diameter best quality heavy type uPVC pipes (RFL/National/Hatim
or equivalent) and will be completed all uPVC fittings like tees, Y, cross-tee, reducer-Y, elbows, bends, Offset,
sockets, reducers, test opner or door socket, clean out cap and vent cowl with solvent cement clamping to
wall or hanging under ceiling or concealed properly at an interval of not more than 1200mm as in
drawing, groove cutting in brick work, R.C.C floor, making holes and mending good the damages including
supply and carriage of all materials, labour, tools, incidentals etc. complete as per drawing and direction of the
Consultant/PD. Product shall be as per BSTI approved manufacture standard or ASTM, BS/ISO/IS standard.

Supplying and laying uPVC underground pipe including fitting, fixing etc. all complete as per approved design,
drawing, relevant specification and accepted by the Engineer- in-
charge.
a). 150 mm dia, 6.2 mm thick
b). 200 mm dia, 7.7 mm thick
c). 250 mm dia, 9.6 mm thick
d). 300 mm dia, 12.1 mm thick
e). 350 mm dia, 12.1 mm thick
f). 400 mm dia, 12.1 mm thick
Supplying and laying 80 Schedule Pressure Pipe: all complete approved design, drawing,
relevent specification and accepted by the Engineer- in- charge.
a). 50 mm dia, wall thickness 3.9 mm to 4.5 mm
b). 65 mm dia, wall thickness 5.8 mm
c). 75 mm dia,wall thickness 6.8 mm
d). 80 mm dia,wall thickness 6.8 mm
e). 100 mm dia,wall thickness 6.8 mm
f). 150 mm dia,wall thickness 6.8 mm

Construction of masonry inspection pits inside measurement are given below, with 150 mm thick brick work in
cement mortar (1:4) with 100 mm thick R.C.C. top slab (1:2:4) with 1% reinforcement, (600mmx600mm) or
600mm dia water sealed R.C.C. Manholecover in/c. necessary earth work, side filling and one brick
flat soling, 75mm thick (1:3:6) base concrete for making invert channel and 12 mm thick (1:2) cement
plaster with neat finishing etc. all complete up to the given depth as per drawing, relevent specification
and direction of the Engineer-in-charge.

a). (900 x900 mm)


b) (1350 x 1350mm)
c) (1800 x1800)
b). (1200 x1200 mm)
Execution of boring through different strata for all-through 650x450x400 dia vertical
bore hole up to design depth interval. This is also includes sinking with drawing casting pipe and complete as per
specification & direction of Engineer.
a) From depth 000m- 31m
b) From depth 32-62m
c) From depth 62-92m
d) From depth 93-123m
e) From depth 124-163m
Supplying and Installation of 300 mm Dia MS Housing Pipe wall thickness 6 mm as per
specification & direction of Engineer.
Supplying and Installation of 150 mm Dia SS Filter, Slot opening 30/35 as per
specification & direction of Engineer.
Supplying and Installation of the following fittings and fixtures as per specification &
direction of Engineer.
a) 150 mm blank pipe wall thickness 4 mm
b) 200x150mm Dia MS Reducer
c) 150mm Dia bail Plug cop
d) 150mm Shocket
e) Tie rod 500mm -100mm Long (37mm dia MS rod)
f) Centralizer 150mm Dia made by 12.5 mm dia plain rod
g) Welding rod SS+MS

Supplying and Making pea gravel pack around tha tube well fixtures and bore hole with supply of approved
including sieving washing etc. complete as per standerd practice and extra amount required for extra depth bellow
the tube well fixtures as per specification & direction of Engineer.

Development by air compressor as per specification & direction of Engineer.


Development by submersible pump as per specification & direction of Engineer.
Supplying, Fitting and Fixing of Housing Pipe filter etc. as per specification & direction
of Engineer.
Supply of Submersible Pump Motor set Technical specification for submersible pump
motor set ( 85 HP)

Item :- Bore well Pump Motor Type Brand :- KSB


Pump type :- Submersible
Pump motor model :- BPN 374/4+NB 623 Head :- 120-130 M
Discharge capacity :- (150-180) m3/Hr.
Motor type :- Submersible, Water filled, Water lubricated & Rewind able. Impeller Material :- Bronze
Shaft protection Sleeve :- Bronze Bearing Bush :- Bronze
Pump Shaft :- Cr. Steel
Pump Stage Bowl :- Cast Iron.

Motor rating :- (75HP-85HP)/63KW. Current (Approx) :- (100-126 Amps). Speed :- 2850-3000 rpm.
Starting Method : - Star-Delta.
Power connection :- 3 Ph, 50 Hz, and 400 V (± 10%)
Cable size :- 2×3 Core, 25mm2 (03 double meter cable included with motor) Pump Delivery :- 6" dia flanged
type with internal NRV.
Pump motor outer dia :- 206 mm (Approximate) Pump+ Motor total length :- 2412 mm (Approximate). Pump
motor overall efficiency :- More than 75% Standardization :- ISO 9001.
Make/Origin :- KSB Pumps Ltd, Germany, UK, France or equivalent.
Supply & installation of sheet steel clad (16 SWG) dust vermin proof free standing floor mounting type 415 v,
50 Hz indoor type LT panel with necessary painting having comprising components 62 HP Star-Delta
auto Control Panel with all necessary protections Incoming circuit breaker of sufficient capacity,
Ammeter with ASS Volt meter with VSS, C/T of power current ratio & burden, Main Contactors,
Auxiliary Contactors, Indicating light for on, off, Trip indicator, O/L relay, Pneumatic timer, Pump guard for phase
failure /Dry run protection reverse phase sequence protection, Cable ties & lugs, Connectors etc.

Major Components:-
Bhartiya Cutler-Hammer, Telemechanique France, Siemens or equivalent etc.
Providing & fixing additional marine cable for submersible Pump Motor Set manufactured according
to DIN/NEMA/IEC/BS/VDE/JIS & ISO 9001 standard (Foreign
made) & as per sample accepted/approved by the Engineer.
i) 3C – 25 sq mm

Providing & fixing of following dia 3.78 meter (10'-0) long column pipe to be connected with submersible Pump
Motor Set made of steel column pipe (API-5L, grade-B) with all standard accessories including special flange
at both ends including anticorrosive painting etc. as per sample accepted/approved by the Engineer.

i) 200 mm (8") dia

Supply, installation, testing & commissioning of following 425B, 3-phase 50Hz, electronically
controlled, automatic voltage stabilizer/regulator locally assembled in metallic painted cabinet suitable for
input voltage range 300-460V, Output steeples continuous voltage 400V ± 3% correction speed 20V/Sec
(minimum) complete with phase failure and spike & surge-fluctuation voltage protection, auto shut off at high
& low voltage with auto reset system, overload & instantaneous short circuit protection by MCCB & relay,
transient suppression circuit, ON-OFF-TRIP indicators, voltmeter.

a) 250 KVA AVR


Assembled by AEG / MICRO / NAVANA / RAHIMAFROOZ or equivalent approved
by the Engineer-in-Charge.
Supply & installation
i) 150 mm dia gate valve-01 No.
ii) MS bass plate with lifting hook-01 No
iii) 150 mm dia rubber flexible-01 No.
iv) Pressure Gauge-01 No.
v) Mounting Clamp-01 No.
vi) 150 mm Flow meter-01 No.
vii) Short piece, Nipple, Nut-bolt, gasket, etc. -01 Lot
viii) Floor mat- 4 nos
Cost of installation & Commissioning of (75-85 HP) submersible pump, Motor.

Providing & laying of the following PVC insulated & sheathed cable (NYY)/ coloured ECC wire (BYA)
connecting at both ends, through PVC pipe & accessories in the following manner. All electrical contacts
shall be of brass/copper connected through connector or soldering ( no twisting shall be allowed) and cables
shall be manufactured and tested according to relevant IEC/BDS/BS/VDE standards and as per detailed
specification mentioned in Annexure-A. The work shall be carried out as per
direction/approval/acceptance of the Engineer .

In pucca floor through PVC pipe by cutting trench of necessary size and mending the
damages good by brick soling, 75 mm (1:2:4) CC work with neat cement finishing etc,
Cables manufactured by BBS/MEP/Poly Super sign/Fecto Industries
(Citizen)/Evana/Khawaja
(777 Energy Cable) or equivalent accepted/approved by the Engineer.
1C-4 × 120 sq mm (NYY/2XY) with 70 sq. mm (BYA) ECC wire through PVC pipe of
minimum inner dia 75 mm having wall thickness of 3 mm
In Pucca floor.

Earthling the electrical installation with 40mm (1.5") dia G.I pipe (Earth electrode) having 6.35mm dia
hole across the pipe at 305mm interval securedly bonded by soldering with 2 nos of No2 SWG HDBC earth
leads with its protection by 20 mm (3/4") dia G.I pipe up-to plinth level run at a depth of 609.6 mm ( 2ft) below
G.L up to main board to be earthed including necessary connecting copper sockets, bolts, nuts, etc.
complete for maintaining earth resistance within 1 ohm.

a) Depth of bottom of main electrode at 37338 mm ( 122.5 ft) from GL & length of per
set electrode 36576 mm ( 120 ft)

b) Construction of Earthling inspection pit inside measurement 600 mm × 600 mm with 250 mm thick brick in
cement morter (1:4) with 100 mm thick RCC topo slab (1:2:4) with 1% re-inforcement 450 mm dia water
sealed CI man-hole cover with locking arrangement including necessary earth works, site filling and one brick
flat soling 75 mm thick (1:3:6) base concrete for making inlet channel & 12mm thick (1:2) cement plaster with
neat finishing etc. all complete up to a depth of 75 meter.

c) Providing & fixing 25.4 mm (1") dia 457 mm (1.5 ft) long solid copper rod with sharp top end for arresting
lightning securely bonded with 6.6 mm thick 150 mm × 150 mm Copper baser plate to be recessed in wall
complete with nuts, bolts, C.C work etc.
d) Providing & drawing No-2 HDBC wire through 12.7 mm ( ½ ") dia G.I pipe including
fitting, fixing the G.I pipe in wall or column complete as required.

Providing & fixing of 18 SWG metal clad 500 volt 3 phase two way change-over switch of following capacity
complete with moving & fixed copper contacts, copper buses, brass nuts and bolts, 3mm thick ebonite sheet
separators insulators, operating handle etc. complete including necessary hammer painting on enclosure.

400 Amps. rating.


Supplying of 415V, 3 phase, 50Hz following capacity Control Circuit Breaker feeder unit as per following
specification with thermal over current & instantaneous electromagnetic short-circuit release
manufactured and tested as per NEMA/IEC/VDE/BS/JIS standards (adjustable type above 100A
rating) for sub-station
L.T panel.
Rated operating voltage: 220-690 V,
Rated insulation voltage 690 volt
Rated impulse withstand voltage 6 KV
Utilization Category: A or B
400A (35KA) TPMCCB
AEG / Dorman Smith /MEM /Siemens /Eaton/Schneider or equivalent
accepted/approved by the Engineer.

Miscellaneous Works
Marking

Painting different marking of Apron by spray machine with best quality rubberized synthetic high built
approved quality and brand runway marking paint mixed with best quality T-4 Thinner 20% of Paint, cleaning
and washing the surface with coir and wire brush & finishing the edges properly etc. all complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.
Yellow
Red
Blue
Black
White
Landscapping Work as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Road Signs

Stack Type Sign Board: Providing Supplying & fixing single sided Sign board of 4mm ACP with face fully
covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols
accordingly, fixed with the help of Very High Bond tape of 24mm wide and 2.3mm thick. The board shall
have a two leg support with necessary holes, nuts bolts & caps. The boards shall be fixed on two nos.
RCC foundations complete with all relevant specs confirming to detail drawing enclosed. Material should
be in compliance with Code of practise for Road signs according to BRTA (Detail as per enclosed
drawing). All complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Gantry Type over Head Sign: Fabrication Supplying & Erecting of Over Head Gantry structure made of steel
work in built up tubular (round, suare or rectangular hollow tubes etc. trusses etc.) including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer, welding and bolted with special
shaped washers etc. including necessary foundation work complete with centering/ shuttering etc. as per
approved drawing and to the satisfaction of engineer in charge. The whole gantry shall be painted with 2 Coat of
Epoxy paint of desired colour. Messages and graphics shall be plotter cut with overlay sheeting or HIGH
INTENSITY PRISMATIC GRADE Type IV fixed with Very High Bond tape of 24mm wide and 2.3mm thick and
rivets, fixed on to structure with the help of suitable expansion fastners. Material should be in compliance with
Code of practise for Road signs according to BRTA.(Detail as per enclosed drawing). All complete as
per design, drawing, specification of relavant chapter and accepted by the Engineer.

Map Type Sign Board: Providing Supplying & fixing single sided Sign board of 4mm ACP with face fully
covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and symbols
accordingly, fixed with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board shall
have a two leg support with necessary holes, nuts bolts & caps. The boards shall be fixed on two nos.
RCC foundations with CC 1:2:4 laid with the help of shuttering complete with all relevant specs
confirming to detail drawing. Material should be in compliance with Code of practise for Road signs
according to BRTA. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer.

Flag Type Sign Board: Providing Supplying & fixing double sided cantilever Sign board of 4mm ACP
with face fully covered by RETRO REFLECTIVE MICRO PRISMATIC Type IV Sheeting, and messages and
symbols accordingly, fixed with the help of Very High Bond tape of 24mm wide and 2.3mm thick. .The board
shall have a single leg support with necessary holes, nuts bolts & caps. The boards shall be fixed on RCC
foundations complete with all relevant specs confirming to detail drawing . Material should be in compliance with
Code of practise for Road signs according to BRTA. all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Miscelleneous Sign: Making both side support of the sign board by 75 to 100mm MS pipe and making framing
with pipe, angle or flat bar as required face fully covered by RETRO REFLECTIVE MICRO PRISMATIC
Type IV Sheeting, and messages and symbols accordingly, fixed with the help of Very High Bond tape of
24mm wide and 2.3mm thick, compliance with Code of practise for Road signs according to BRTA. all complete
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Traffic Signs
Over head sign
Making of Sign board with steel member as per design and printed on 12 BWG sheet all complete as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Making both side support of the sign board by 200mm MS pipe and making a frame with 100, 75, 50 & 25mm
dia MS pipe with required bracing all complete as per design,
drawing, specification of relavant chapter and accepted by the Engineer.
Way wide sign
Making of Sign board with steel member as per design and printed on 12 BWG sheet all complete as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Making both side support of the sign board by 75 to 100mm MS pipe and making
framing with pipe, angle or flat bar as required all complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Post type sign
Making of Sign board with steel member as per design and printed on 12 BWG sheet all complete as per design,
drawing, specification of relavant chapter and accepted by the
Engineer.
Making a sign post of 75 to 100mm dia MS pipe all complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Toll Booth Rumble strips all complete as per design, drawing, specification of relavant
chapter and accepted by the Engineer.

Providing painting at the top of the road surface as road marking in two coats with approved best
quality and colour of synthetic paint from authorized local agent of the manufacturer in a sealed container
having high water resistance, high bondability & flexibility, using specific brand thinner applied by
machine or others over a coat of priming, providing elapsing time for drying including surface cleaning from
dust, oil or dirt, smoothening, finishing necessary tools etc. all complete & approved and accepted by the
Engineer.

Exposed brick works (for exterior wall without outside plaster) with special quality sorted out first class
bricks, very carefully laid in cement sand (F.M. 1.2) mortar (1:4) in superstructure with uniform width and
depth of joints, true to vertical and horizontal lines including raking out joints, scaffolding, soaking the bricks
at least for 24 hours before use, washing and screening of sand, curing at least for 7 days and high class flush
pointing with cement sand (F.M. 1.2) mortar (1:1) including cost of water, electricity and other charges etc all
complete as per design, drawing, specification of relavant chapter and accepted by the Engineer.

Sub-Total (Civil Works)


Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

cum 5380.30

cum 3655.00

cum 51.10

cum 1608.20

cum 838984.00

Rm 150000.00

cum 576266.50

cum 31702.00

Sqm 342089.00

Sqm 160718.00
Cum 28,650.00

Cum 53,580.00

Sqm 110500.00
Sqm 534000.00

Cum 23,010.00

Cum 10,190.00

Cum 17,800.00

Cum 44,100.00

Sqm 187350

Rm 56880.00

Each 64100.00

Sqm 190000.00

Rm 29040.00

Cum 14,700.00

Cum 13,950.00

Sqm 105000.00
Sqm 150000.00

Cum 8,650.00
Cum 5,550.00

Sqm 15000.00

Sqm 5500

Cum 2603.95

Cum 2603.95

Cum 959.00

Cum 10563.00

Ton 2350.99

Sqm 15177.00

Sqm 56280.00

Rm 2452.00
Rm 10.00
Rm 79.00
Rm 15.00
Rm 175.00
Rm 200.00
Rm 3276.00
Rm 1909.00

Sqm 8000.00

No 30.00 800.00 24,000.00

Rft 500.00
Rft 3900.00
Rft 4550.00
Rft 4610.00
Rft 1200.00
Rft 150.00

Rft 6911.00
Rft 200.00
Rft 200.00
Rft 6912.00
Rft 200.00
Rft 15000.00

No 345.00
No 10.00
No 1.00
No 3.00
Rm 124.00
Rm 124.00
Rm 120.00
Rm 120.00
Rm 156.00

Rm 560.00

Rm 240.00

Rm 240.00

Rm 24.00
Nos 4.00
Nos 4.00
Nos 72.00
Nos 84.00
Nos 28.00
Job 4.00

Rm 732.00

Job 4.00
Job 4.00

Rm 824.00

Set 4.00
Set 4.00

M 1000.00

No 112.00

No 4.00

lot 4.00
Job 4.00
M 120.00

Set 16.00

Set 16.00

Set 16.00

M 160.00

Job 2.00

No 4.00
sq.m 2616.00
sq.m 233.00
sq.m 181.00
sq.m 15.00
sq.m 447.00

Job 1.00

sq.m 42.00

120.00

sq.m 5.00

sq.m 4.00
sqm 4.50

sqm 6.00

Job 3.00

sqm 3.00

Job 2.00

sqm 8.00

Job 5.00

Job 8.00

Sqm 3150.00

Cum 176.00
Item No.

3.5
3.5.1

3.5.1.1

a
b
c
d
e
f
g
h
i
j
k

3.5.1.2

a
b
c
d

3.5.1.3

a
b

3.5.1.4

3.5.1.5

a
b
c
3.5.1.6

3.5.1.7

a
b

3.5.1.8

3.5.1.9

3.5.2

3.5.2.1

c
3.5.2.2

3.6
3.6.1

3.6.1.1

3.6.1.2

3.6.1.3

3.6.2

3.6.3

3.6.4

3.6.5

3.6.6

3.6.7
3.6.8

3.6.9

3.6.10

3.6.11

3.6.12

3.6.13

3.6.14

3.6.15
3.6.16

3.6.17

3.6.18

3.6.19
3.6.20

3.6.21

3.6.22

3.6.23

3.6.24
3.6.25

3.6.26

3.6.27
3.6.28

3.6.29

3.7.1

3.7.1.1

a
b
c
d
e
f
g
h

3.7.1.2

3.7.1.3

3.7.1.4

a
b
c
d
e
f
3.7.1.5
3.7.1.6

3.7.1.7

3.7.1.8

a
b
c
d
e
f
g
h
i
j

3.7.1.9

3.7.1.9.1
a
b
c
3.7.1.9.2
a
b
c
3.7.1.9.3
a
b
c
3.7.1.10

3.7.1.11
3.7.1.12
3.7.1.13
3.7.1.14
3.7.1.15
a
b
c
3.7.1.16

3.7.1.17
3.7.1.18
3.7.1.19

3.7.1.20

3.7.1.21

3.7.1.22

d
e

3.7.2
3.7.2.1

3.7.2.1.1

3.7.2.1.2

3.7.2.1.3

3.7.2.1.4

3.7.2.1.5
3.7.2.1.6

3.7.2.2

3.7.2.2.1

3.7.2.2.2

3.7.2.2.3
3.7.2.2.4

3.7.2.2.5

3.7.2.2.6

3.7.2.3

3.7.2.3.1
3.7.2.3.2

3.7.2.3.3

3.7.2.3.4

3.7.2.3.5

3.7.2.5

3.7.2.6

3.7.2.6.1
3.7.2.6.2

3.7.2.6.3
3.7.2.6.4

3.7.2.6.5

3.7.2.7
3.7.2.7.1

3.7.2.7.2
3.7.2.7.3

3.7.2.7.4

3.7.2.8

3.7.2.8.1

3.7.2.8.2
3.7.2.8.3
3.7.2.8.4

3.7.2.8.5
3.7.2.8.6
3.7.2.8.7

a
b
c
d
e
f
3.7.2.9
a
b
c
d
e
f
g
j
i
j
k
l
m
n
3.7.2.10
a
b
c
d
e
f
g
j
3.7.2.11

3.7.2.11.1

3.7.2.11.2

3.7.2.11.3

3.7.2.11.4

3.7.2.11.5

3.7.2.11.6
3.7.2.11.7
3.7.2.11.8

3.7.3
3.7.3.1
3.7.3.2

3.7.3.3

3.7.3.4

3.7.3.5

3.7.3.6

3.7.3.7
3.7.3.8

3.7.3.9

3.7.3.10

3.7.3.11

3.7.3.12

3.7.3.13
3.7.4

3.7.4.1

3.7.4.2

3.7.4.3
3.7.4.4

3.7.4.5

3.7.4.6

3.7.4.7

3.7.4.8

3.7.4.9
3.7.4.10

3.7.4.11

3.7.4.12

3.7.4.13

3.7.4.14

3.7.4.15

3.7.4.16

3.7.4.17
3.7.4.18

3.7.4.19

3.7.5

3.7.5.1
3.7.5.2

3.7.5.2.1

3.7.5.2.2

3.7.5.2.3

3.7.5.3

3.7.5.4
3.7.5.5

3.7.5.6

3.7.5.7

3.7.5.8

3.7.5.9
3.7.5.10

3.7.5.11

3.7.6
3.7.6.1

5.2
5.2.1
5.2.1.1
5.2.2

5.2.2.1
5.2.3

5.2.4

5.2.4.1

5.2.4.2
5.2.5

5.2.5.1
5.2.6

5.2.6.1

5.2.6.2

5.2.6.3

5.2.6.4

5.2.6.5
5.2.6.6

5.2.6.7

5.2.6.8

5.2.6.9

5.2.6.10

5.2.6.11

5.2.6.12

5.2.6.13
5.2.6.14

5.2.6.15

5.2.6.16

5.2.6.17

5.2.6.18

5.2.6.19

5.2.6.20

5.2.7
5.2.7.1

5.2.7.2

5.2.7.3

5.2.7.4

5.2.8

5.2.8.1
5.2.9

5.2.9.1
5.2.9.1.1

5.2.9.1.2

5.2.9.1.3

5.2.9.1.4

5.2.9.1.5

5.2.9.1.6

5.2.9.1.7

5.2.9.1.8

5.2.9.1.9

5.2.9.1.10

5.2.9.1.11

5.2.9.1.12

5.2.9.1.13

5.2.9.1.14

5.2.9.1.15

5.2.9.1.16

5.2.9.1.17

5.2.9.1.18

5.2.9.1.19
5.2.9.1.20

5.2.9.1.21

5.2.9.1.22

5.2.9.1.23

5.2.9.124

5.2.9.1.25

5.2.9.1.26

5.2.9.1.27

5.2.9.1.28

5.2.9.1.29

5.2.9.1.30

5.2.9.2
5.2.9.2.1

5.2.9.2.2

5.2.9.2.3

5.2.9.2.4

5.2.9.2.5

5.2.9.2.6

5.2.9.3
5.2.9.3.1

5.2.9.3.2

5.2.9.3.3

5.2.9.3.4

5.2.9.3.5

5.2.9.3.6
5.2.9.3.7

5.2.9.3.8

5.2.9.3.9

5.2.9.3.10

5.2.9.3.11

5.2.10

5.2.10.1

5.2.10.2

5.2.10.3

5.2.10.4

5.2.10.5

5.2.10.6

5.2.10.7

5.2.10.8

5.2.10.9

5.2.10.10

5.2.10.11
5.2.10.12

5.2.10.13

5.2.10.14

5.2.10.15

5.2.10.16

5.2.10.17

5.2.10.18

5.2.10.19

5.2.10.20

5.2.10.21

5.2.10.22

5.2.11

5.2.11.1

5.2.11.2

5.2.11.3

5.2.11.4

5.2.11.5
5.2.12

5.2.12.1

5.2.12.1.1
5.2.12.1.2
5.2.12.1.3
5.2.12.1.4
5.2.12.1.5
5.2.12.1.6
5.2.12.1.7
5.2.12.1.8
5.2.12.1.9
5.2.12.1.10
5.2.12.2

5.2.12.2.1
5.2.12.2.2
5.2.12.2.3
5.2.12.2.4
5.2.12.2.5
5.2.12.2.6
5.2.12.2.7
5.2.12.2.8
5.2.12.3
5.2.12.3.1
5.2.12.3.2
5.2.12.4
5.2.15.1
5.2.15.2
5.2.12.5
5.2.12.5.1
5.2.12.5.2
5.2.12.5.3
5.2.12.5.4
5.2.12.5.5
5.2.12.5.6
5.2.12.5.7
5.2.12.5.8
5.2.12.6
5.2.12.6.1
5.2.12.6.2
5.2.12.7
5.2.12.7.1
5.2.12.7.2
5.2.12.7.3
5.2.12.7.4
5.2.12.7.5
5.2.12.8
5.2.12.8.1
5.2.12.8.2
5.2.12.8.3
5.2.12.8.4
5.2.12.8.5
5.2.12.8.6
5.2.12.8.7
5.2.12.9
5.2.12.9.1
5.2.12.9.2
5.2.12.10
5.2.12.10.1
5.2.12.10.2
5.2.12.10.3
5.2.12.10.4
5.2.12.10.5
5.2.12.11
5.2.12.11.1
5.2.12.12
5.2.12.12.1
5.2.12.12.2
5.2.12.12.3
5.2.12.12.4
5.2.13

5.2.13.1
5.2.14

5.2.14.1
5.2.14.2
5.2.14.3
5.2.15

5.2.16

5.2.16.1
5.2.16.2
5.2.17

5.2.18

5.2.18.1
5.2.18.1.1
5.2.18.1.2
5.2.18.2
5.2.18.2.1
5.2.18.2.2
5.2.18.2.3
5.2.18.2.4
5.2.18.2.5
5.2.18.2.6
5.2.18.2.7
5.2.18.3

5.2.18.3.1
5.2.18.3.2
5.2.18.3.3
5.2.18.3.4
5.2.18.3.4
5.2.18.3.5
5.2.18.3.6
5.2.18.3.7
5.2.18.3.8
5.2.18.3.9
5.2.18.3.10
5.2.18.3.11
5.2.18.4
5.2.18.4.1
5.2.18.4.2
5.2.18.4.3
5.2.18.4.4
5.2.18.4.5
5.2.18.4.6
5.2.18.4.7
5.2.18.4.8
5.2.18.4.9
5.2.18.4.10
5.2.18.4.11
5.2.18.4.12
5.2.18.4.13
5.2.18.4.14
5.2.18.4.14
5.2.18

5.2.18.1
5.2.18.2
5.2.18.3
5.2.19

5.2.20

5.2.21

5.2.22

5.2.22.1
5.2.24

5.2.25

5.2.25.1
5.2.25.2
5.2.25.3
5.2.25.4
5.2.25.5
5.2.26

5.2.26.1
5.2.26.2
5.2.26.3
5.2.26.4
5.2.26.5
5.2.26.6
5.2.26.7
5.2.26.8
5.2.26.8
5.2.26.9
5.2.26.10
5.2.26.11
5.2.26.12
5.2.26.13
5.2.26.14
5.2.26.15
5.2.26.16
5.2.27

5.2.27.1
5.2.27.2
5.2.27.3
5.2.27.4
5.2.27.5
5.2.27.6
5.2.27.7
5.2.27.8
5.2.28
5.2.29
5.2.30

5.2.31
5.2.31.1
5.2.31.2
5.2.31.3
5.2.31.4
5.2.31.5
5.2.32

5.2.32.1
5.2.32.2
5.2.32.3
5.2.32.4
5.2.32.5
5.2.33
5.2.33.1
5.2.33.2
5.2.34

5.2.34.1
5.2.35

5.2.35.1
5.2.36

5.2.37

5.3
5.3.1

5.3.1.1

5.3.1.2

5.3.2

5.3.2.1
5.3.3

5.3.3.1

5.3.3.2

5.3.3.3

5.3.3.4

5.3.3.5

5.3.3.6

5.3.3.7

5.3.3.8

5.3.3.9
5.3.3.10

5.3.3.11

5.3.3.12

5.3.3.13

5.3.3.14

5.3.3.15

5.3.3.16
5.3.3.17

5.3.3.18

5.3.3.19

5.3.3.20

5.3.3.21

5.3.3.22

5.3.3.23
5.3.3.24

5.3.3.25

5.3.3.26

5.3.3.27

5.3.3.28

5.3.3.29
5.3.3.30

5.3.3.31

5.3.3.32

5.3.3.33

5.3.5

5.3.5.1
5.3.5.2

5.3.5.3

5.3.5.4
5.3.5.5

5.3.5.6

5.3.5.7

5.3.5.8

5.3.5.9

5.3.5.10

5.3.5.11
5.3.5.12

5.3.5.13

5.3.5.14

5.3.5.15

5.3.5.16

5.3.5.17

5.3.5.18

5.3.5.19

5.3.5.20

5.3.5.21

5.3.5.22

5.3.5.23

5.3.5.24

5.3.6

5.3.6.1

5.3.6.2

5.3.7

5.3.7.1
5.3.7.2

5.3.7.3

5.3.7.4

5.3.7.5

5.3.7.6

5.3.7.7

5.3.7.7

5.3.7.8

5.3.7.9
5.3.7.10

5.3.7.11

5.3.7.12
Description of Item

Fire Fighting System


Fire Hydrant and Sprinkler

Supply, delivery, installation, testing and commissioning of all MS pipes (ASTM 53 SCH-40 wet steel or
BS1387 Class B) of various size for Sprinkler system. The works shall include all fittings, joints, tap off,
flexible joints, necessary support, fixing, brackets, hanger, vibration isolators, base plates, civil work etc. as per
design, drawing, specification of relavant chapter and accepted by the Engineer.

DN 25mm pipe
DN 32mm pipe
DN 40mm pipe
DN 50mm pipe
DN 65mm pipe
DN 80mm pipe
DN 100 mm pipe
DN 150 mm pipe
DN 200 mm pipe
DN 250 mm pipe
DN 300 mm pipe
Supply, delivery, installation, testing and commissioning sprinkler heads complete with dropper pipes, heat shield,
sprinkler guards, where required etc. as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Upright 8.0 ( Standard )
Upright 5.6 ( Standard )
Upright 5.6 ( Quick Response )
Pendent 5.6 ( Standard )

Supply, delivery, installation, testing and commissioning sprinkler zone control valves (motorized butterfly
valve), each sprinkler control valve shall consist of stop valves, alarm valves, drain and test valves,
automatic air release valve, non-return valve, leather belt and lock, isolation valves c/w fire rated cable, MS
conduit etc to respective fire alarm panel etc. as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

DN 150mm
DN 100mm

Supply, delivery, installation, testing and commissioning sprinkler Alarm Check Valves assembly, motorized
butterfly valve, check valve, pressure gauges, alarm motor and gong c/w pipe, valve connection to drain, leather
belt and lock, fire rated cable, GI conduit etc to respective fire alarm panel etc as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

DN 200mm

Supply, install and commission fire stand pipe and hose system including DN 65 hose connection valve with
DN 40 adapter, DN 65 Pressure Reducing Valve, complete in all respects as per design, drawing, specification
of relavant chapter and accepted by the Engineer.

Hose Station Connection


DN 40 mm Drain Valves c/w end cap
DN 25mm automatic air release valve
Supply, delivery, installation, testing and commissioning, from fire department connection point to fire
stand pipe and hose system header inclusive of check valve, fittings, connection and fixing as specified
and location shown in drawings. The work shall include all necessary supports, brackets, fittings, elbows,
bends, tees, junctions, etc; as per design, drawing, specification of relavant chapter and accepted by the Engineer.

4-way Fire department connection complete with check valve, metal cabinet, ball drip
drain
DN 150mm fire department connection pipe c/w fire rating box if
necessary

Supply, delivery, installation, testing and commissioning of flow switches c/w fire rated cable, GI conduit etc to
respective fire alarm panel, complete with all necessary accessories as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

DN 200 mm
DN 150 mm

Supply, delivery, installation, testing and commissioning, of Pillar Hydrant including hose box at outer
premises. The work shall include all necessary supports, brackets, fittings, elbows, bends, tees, junctions, etc;
and providing all necessary accessories as per design, drawing, specification of relavant chapter and accepted by
the Engineer.

DN 65mm, 2-Way
Supply, deliver, prepare and application of paint for entired installed fire hydrant & sprinkler system
including subsystem and accessories as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
For Fire Pump Room

Supply, delivery, installation, testing and commissioning of Horizontal Split Case Centrifugal Fire Pump
Electric and Engine driven & Jockey Pump complete with motors, engine, foot valves, isolation vale, strainer,
flexible connection, air pressure vessel, pressure gauge sensors, pressure switches, vortex plate, electrical
cabling, control panel and all necessary accessories as per design, drawing, specification of relavant chapter
and accepted by the Engineer.

Electrical Motor Driven Main Fire Pump


Pump Type : Horizontal Split Case Centrifugal
Rated Flow: 1250 US GPM
Head : 130 M
RPM: 2900
Certification of Pump : UL Listed, FM Approved
Certification of Motor : UL Listed, FM Approved
Certification of Control Panel : UL Listed, FM Approved
Diesel Engine Driven Main Fire Pump
Pump Type : Horizontal Split Case Centrifugal
Rated Flow: 1250 US GPM
Head : 130 M
RPM: 2900
Certification of Pump : UL Listed, FM Approved
Certification of Engine : UL Listed, FM Approved
Certification of Control Panel : UL Listed, FM Approved
Electrical Motor Driven Jockey Pump
Pump Type : Vertical Multistage
Rated Flow: 50 US GPM
Head : 140 M
RPM: 2900
Certification of Control Panel : UL Listed, FM Approved

The system accessories and manufacturer's parts of the system or system components (including hardware
and software) which are not listed above, but required to form a complete functional system which meet the
design and operational intent complying with codes and standards. The contractor shall propose and itemize here
with unit cost or per lot.

Plumbing and Sanitary Works


Commode
Supplying, fitting and fixing foreign made VIP quality Smart Commode with automatic heating, drying, eleaning,
sensor-flush system including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Supplying, fitting and fixing foreign made best & approved quality with automatic sensor
flush system including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain closed coupled
Commode ‘P’ or ‘S’ type with low down/flush tank and flush valve including all internal fittings as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
Super quality: TOTO, American Standard, Duravit, Japanese or European origin or Equivalent of
approximate size (695mm x 412mmx 880mm) with flush tank.

Free Standing Built -In Sensor Urinal:


Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain Free Standing
Built -In Sensor Urinal including all internal fittings as per
design, drawing, specification of relavant chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(445mm x 355mm x 330mm)
Wall Hung Flash Valve Urinal:
Supplying, fitting and fixing foreign made approved quality white glazed porcelain Wall Hung Flash Valve
Urinal including all internal fittings as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(610mm x 375mm x 85mm)
Hand Wash Basin with Full or Half Pedastal:
Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain Hand Wash
Basin with Full or Half Pedastal including all internal fittings as per design, drawing, specification of relavant
chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(525mm x 415mm x 860mm)
Under Counter Square Basin:
Supplying, fitting and fixing foreign made best & approved quality white glazed
porcelain Under Counter Square Basin including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
TOTO, Duravit or Equivalent / Japanese or European Origin of approximate size
(530mmx430mmx220mm)
Stainless Steel Sink with Sink Tray:
Supplying, fitting and fixing foreign made best & approved quality Stainless Steel Sink with Sink Tray
including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.
Stainless Steel Sink with Sink Tray (Size 450mm x 1050mm)
100% SS304 coating.
Soap Dispenser :
Supplying, fitting and fixing foreign made best & approved quality Soap Dispenser including all internal
fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
JVD, Teka or Equivalant of approximate size (200-220mm x 100-120mm)
Toilet Paper Holder with Cover :
Supplying, fitting and fixing foreign made best & approved quality Toilet Paper Holder
with Cover including all internal fittings as per design, drawing, specification of relavant chapter and accepted by
the Engineer.
Toto, Grohe, American Standard or Equivalent
Glass Mirror:
Supplying, fitting and fixing foreign made best & approved quality Glass Mirror including all internal
fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Rolled Hand Tissue dispenser and Automatic Hand Drier
a) Supplying, fitting and fixing foreign made best & approved quality stainless steel Rolled Hand Tissue
dispenser as per design, drawing, specification of relavant chapter
and accepted by the Engineer.

b) Supplying, fitting and fixing foreign made best & approved quality Automatic Hand
Drier as per design, drawing, specification of relavant chapter and accepted by the Engineer.
Basin Mixture:
Supplying, fitting and fixing foreign made best & approved quality Basin Mixture
including all internal fittings as per design, drawing, specification of relavant chapter and accepted by the
Engineer.
Toto, Grohe, Hans Grohe or Equivalnet
Push shower and Bib Cock :
Supplying, fitting and fixing foreign made best & approved quality Push shower and Bib
Cock including all internal fittings as per design, drawing, specification of relavant chapter and accepted by
the Engineer.
a). 12 mm C.P Push Shower
b). 12 mm C.P Bib cock
Angle Stop Cock:

Supplying, fitting and fixing foreign made best & approved quality Angle Stop Cock
including all internal fittings as per design, drawing, specification of relavant chapter and accepted by the
Engineer.

a). 12 mm dia stop cock (Special quality)


Grating:
Supplying, fitting and fixing best quality grating in traps or in drains and where necessary including making holes
in walls and floors and mending good the damages and supply and carriage of all materials, labour, tools,
incidentals, etc. all complete as per design, drawing, specification of relavant chapter and accepted by the
Engineer.
a) 125 mm dia Brass/ 304 SS Coated gratings
b) 100 mm x 100 mm size SS Quoted grating with hinged cover 100% Brass/ SS 304
coating
c) 50 mm dia SS Quoted gratings
u-PVC Floor Traps:
Supplying, fitting and fixing the following type floor traps (Siphon or P -trap) for floor drain including making
holes in walls and floors and mending good the damages including supply and carriage of all materials,
labour, tools, incidentals, etc. all complete as per design, drawing, specification of relavant chapter and accepted
by the Engineer.
a). uPVC floor trap 110 mm dia.
b). uPVC floor trap 50 mm dia.
uPVC Pipe & Fitting:

Supplying, fitting and fixing different diameter best quality heavy type uPVC pipes (RFL/National/Hatim
or equivalent) and will be completed all uPVC fittings like tees, Y, cross-tee, reducer-Y, elbows, bends, Offset,
sockets, reducers, test opner or door socket, clean out cap and vent cowl with solvent cement clamping to
wall or hanging under ceiling or concealed properly at an interval of not more than 1200mm as in
drawing, groove cutting in brick work, R.C.C floor, making holes and mending good the damages including
supply and carriage of all materials, labour, tools, incidentals etc. complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

uPVC Pipes :
a). 32 mm dia, 1.6 mm thick
b). 40 mm dia, 1.9 mm thick
c). 50 mm dia, 2.4 mm thick
d).100 mm dia, 4.5 mm thick
e). 110 mm dia, 4.2 mm thick
f). 160 mm dia, 6.2 mm thick
g). 200 mm dia, 7.7 mm thick
h). 250 mm dia, 9.6 mm thick
i). 315 mm dia, 12.1 mm thick
CPVC Pipe & Fitting:

Supplying, fitting and fixing different diameter best quality CPVC Pipe of 10.5 kg/cm2 tested pressure for water
supply as per BSTI approved manufacturer standards or ASTM/BS/ISO/IS standards and fixed in position
with all CPVCfitting such as sockets, bends, elbows, tees, reducing tees, reducing sockets, reducing elbows,
union, plug with all other related accessories and cutting groove / trenches where necessary and filling the same
with earth duly rammed and fixing in walls with holden bats and making holes in floor and walls and supply
and carriage of all materials, labour, tools, incidentals etc. complete as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

a). 12 mm dia, wall thickness 2.8 mm to 3.3 mm


b). 20 mm dia, wall thickness 2.9 mm to 3.4 mm
c). 25 mm dia, wall thickness 3.4 mm to 4.0 mm
d). 32 mm dia, wall thickness 3.6 mm to 4.2 mm
e). 40 mm dia, wall thickness 3.7 mm to 4.3 mm
f). 50 mm dia, wall thickness 3.9 mm to 4.5 mm
g). 65 mm dia, wall thickness 5.8 mm
h). 75 mm dia,wall thickness 6.8 mm
Ball Valve:

Supplying, fitting and fixing best quality CPVC Body gate valve of 12 kg/cm2 tested pressure, including
supply and carriage of all materials, labor, tools, incidentals etc. complete as per design, drawing,
specification of relavant chapter and accepted by the Engineer.

a). 20 mm dia
b). 25 mm dia
c). 32 mm dia
d). 40 mm dia
e). 50 mm dia
f). 65 mm dia
g). 75 mm dia
Pressure Reducing Valve:
Supplying, fitting and fixing pilot operated gate and diaphragm type pressure reducing valves Germany/ Italy/ or
equivalent complete with inlet and outlet service on riser lines to reduce pressure from 30 psi to 7 psi (2.11-0.49
kg/cm2) including making water tight joints of the valves and fitting by using proper sealing compound, supply of
all labour, tools, incidentals, etc. all complete as per design, drawing, specification of relavant chapter and
accepted by the Engineer.

a). 25 mm dia
b). 32 mm dia
c). 40 mm dia
d). 50 mm dia
e). 65 mm dia
Foot Valve with Strainer
Supplying, fitting and fixing best quality float valve with strainer shall be made of cast
iron flange end type complete with companion flanges, gasket, nuts, bolts etc. as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
a). 50 mm dia.
Non-Return Valve / Check Valve :

Supplying, fitting and fixing best quality gun metal non-return valve including supply and carriage of all
materials, labor, tools, incidentals etc. complete as per design, drawing, specification of relavant chapter and
accepted by the Engineer. Product shall be standard quality or approved equivalent. Contractor shall produce
model of product with manufacture certificate or equivalent guide line.

b) 50 mm dia. brass non-return


Inspection Pit:

Construction of masonry inspection pits inside measurement are given below, with 150 mm thick brick work in
cement mortar (1:4) with 100 mm thick R.C.C. top slab (1:2:4) with 1% reinforcement, 450mm dia water
sealed R.C.C. M.H. cover in/c. necessary earth work, side filling and one brick flat soling, 75mm thick (1:3:6)
base concrete for making invert channel and 12 mm thick (1:2) cement plaster with neat finishing etc. all complete
as per design, drawing, specification of relavant chapter and accepted by the Engineer.

a). (600 x 600 mm)


c) (1800 x 1800mm)
Construction of septic tank with walls of brick work in cement mortar (1:6) having a lining of minimum
125 mm R.C.C cast against the walls as per design, drawing,
specification of relavant chapter and accepted by the Engineer.
Construction of Water Meter Pit as per design, drawing, specification of relavant chapter
and accepted by the Engineer.
Sensor Wall Hung Toilet: (Handicap Type)
Supplying, fitting and fixing foreign made best & approved quality white glazed porcelain closed coupled
Sensor Wall Hung (Handicap Type) Commode ‘P’ or ‘S’ type with low down/flush tank and flush valve
including all internal fittings as per design, drawing, specification of relavant chapter and accepted by the
Engineer.
TOTO, Duravit or Equivalent / Japanese or Europian Origin of approximate size
(525mm x 415mm x 860mm)
Wall Hung Lavatory: (Handicap Type)
Supplying, fitting and fixing foreign made best & approved quality Wall Hung Lavatory:
(Handicap Type) including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
Toto. Duravit or Equivalent / Japanese or European Origin of approximate size
(530mmx430mmx220mm)
Piller Cock: (Handicap Type)
Supplying, fitting and fixing foreign made best & approved quality Piller Cock: (Handicap Type)
including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

TOTO, Grohe, Hans Grohel or Equivalent / Japanese or European Origin of approximate


size (530mmx430mmx220mm)

Supplying, fitting and fixing foreign made best & approved quality Grab Bar Flip Type (Handicap Type)
including all internal fittings as per design, drawing, specification of
relavant chapter and accepted by the Engineer.

TOTO, Grohe, Hans Grohel or Equivalent / Japanese or European Origin.


Grab Bar "L" Shape
Supplying, fitting and fixing foreign made best & approved quality Grab Bar "L" Shape
(Handicap Type) including all internal fittings as per design, drawing, specification of relavant chapter and
accepted by the Engineer.
TOTO. Grohe, Hans Grohel or Equivalent / Japanese or European Origin of approximate
size (w:700×d:700mm(120mm away from the wall))

Internal Electrification Works

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following lighting switches, including all necessary cable, termination, concealed GI conduit and
accessories as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

1-Way, 1 gang, lighting switch


1-Way, multi gang, lighting switch
2-Way, 1 gang, lighting switch
2-Way, multi gang, lighting switch
1-Way, 1 gang, metal clad, lighting switch
1-Way, multi gang, metal clad, lighting switch
2-Way, 1 gang, metal clad, lighting switch
2-Way, multi gang, metal clad, lighting switch
Lighting switch wiring point consist of 2x2.5sqmm PVC E and conduit. (Each point does
not exceed 20m), work should be done as per design, drawing, specification of relevant chapter and accepted by
the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the motion detector for toilets, including all necessary cable, termination, concealed GI conduit and
accessories as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following switch socket outlet (S/S/O), including all necessary cable, termination, concealed GI
conduit and accessories as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

1x16A recess mounted universal s/s/o


2x16A recess mounted universal s/s/o
1x16A metal clad recess mounted s/s/o
2x16A metal clad recess mounted s/s/o
1x16A universal s/s/o mounted in underfloor trunking junction box
2x16A universal s/s/o mounted in underfloor trunking junction box (provision)
Wiring point consist of 2x4sqmm PVC + 4sqmm PVC E (Each point does not exceed
70m)
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the hand dryer, including all necessary cables, termination, concealed GI conduit and accessories on
Ground Floor, work should be done as per design, drawing, specification of relevant chapter and accepted by the
Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the invalid toilet warning system, including all necessary buzzer, strobe light, cable, termination,
concealed GI conduit and accessories on Ground Floor, work should be done as per design, drawing, specification
of relevant chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following isolator, including all necessary cable, termination, cable supporting and accessories where
required, work should be done as per design, drawing, specification of relevant chapter and accepted by the
Engineer.
20A DP Isolator
63A DP Isolator
100A DP Isolator
20A 4P Isolator
32A 4P Isolator
40A 4P Isolator
63A 4P Isolator
80A 4P Isolator
100A 4P Isolator
20A DP Switch

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the termination block, including all necessary cable, termination, cable supporting and accessories as
specified and complying with relevant codes, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

16A switch socket outlet universal type duplex for FIDS (UPS)
i. Column mounted or Wall mounted
ii. Ceiling mounted (metal clad)
iii. Floor mounted
16A switch socket outlet universal type duplex for CCTV (UPS)
i. Columned mounted(WP)
ii. Column mounted and wall mounted
iii. Ceiling mounted (metal clad)
16A switch socket outlet universal type duplex for Card Access System (UPS)
i. Column mounted or Wall mounted
ii. Ceiling mounted (metal clad)
iii. Floor mounted
16A switch socket outlet universal type duplex for Security Scanning
Equipment (Floor mounted)
16A metal clad switch socket outlet universal type duplex for maintenance of Escalator
pit (floor mounted) (Emergency)
16A switch socket outlet universal type duplex for Clock System (UPS)
i. Column mounted and wall mounted
16A switch socket outlet universal type duplex for Master Antenna TV System
(Column mounted & Wall
16A switch socket outlet universal type duplex for Signage (Emergency)
i. Floor mounted
ii.Wall mounted
ii. Ceiling mounted (metal clad)
16A metal clad switch socket outlet universal type duplex for Auto sliding doors
(Ceiling Mounted) (UPS)
16A metal clad switch socket outlet universal type duplex for Auto sliding doors
(Floor Mounted) (UPS)
16A switch socket outlet universal type duplex for Water Cooler (Normal)
16A switch socket outlet universal type duplex for Public Telephone (Normal)
Supply and installation of hand dryer complete with 16A metal clad switch socket outlet universal type, work
should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Supply and installation of single socket outlet complete with cabling tapping from emergency source for twin head
20watt emergency battery pack floodlights, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

INTERNAL LIHTING

Supply, delivery, installation, testing and commissioning of the following type of Luminaires, including all cabling
works, termination, ceiling roses in ceiling space, concealed GI conduit, junction box complete with quick male &
female connector, supporting brackets and necessary accessories and link to respective lighting switches as
specified and complying with relevant codes, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

20W LED Frameless Line Light


Frameless panel having L 1195mm*W 295mm *H16mm with PMMA diffuser light guide acrylic plate with fire-
proof function.
Ceiling LED luminaires with hidden aluminum frame in high value design. Ceiling mounting or pendant
mounting, Stainless rope with length adjustable.
Lumen output:110lm/w, CRI(Ra)> 80.
Life time should be more than 50,000 hrs. Color temperature:3000k- 6500K; Operating Voltage: 85~265V,
Power factor=0.95

20W Down Light


Recessed LED downlight. . IP54 (IP20 from above). Body: Pressure die cast aluminum housing with full diffused
recessed mounted LED.Complete with 6500K LED.
Total power: 20 W
Luminaire luminous flux:2200 lm Lumen output:114-127 lm/W Operating Voltage: 85- 265 VAC
CRI:80;CCT:6500K
Life time:30,000-35,000 Hours

2'x2' Panel light 48W


Recessed LED Panel Light . IP54 (IP20 from above) 41 W fully diffused recessed mounted LED luminaire
(595X595mm)
with Extruded aluminum housing. Total Power : 41W,
Luminaire luminous flux: 4500 lm Operating Voltage: 85-265 VAC Efficacy:110-127 Lm/W
CRI: 80, CCt:6500K
Life time: 40,000-50,000 Hours PF:0.95

28W Down Light


A recessed LED downlight. . IP54 (IP20 from above). Body: Pressure die cast aluminum housing with full
diffused recessed mounted LED. Suitable for mounting in ceiling thicknesses of 1-40mm in a Ø136 mm cut-out.
Complete with 6500K LED.
Total power: 28W
Luminaire luminous flux: 3130 lm Lumen output:114-127 lm/W Operating Voltage: 85- 265 VAC
CRI:80;CCT:6500K
Life time: 40,000-50,000 Hours PF:0.95
i) 150W High Bay
ii) 150W High Bay
2x20W LED Tube Light (40W) Water Proof T8 Tube Light Fixture Housing material ABS+PS. Suitable 2x20
W T8 Tubelight .
Lumen output:110-127lm/W Operating Voltage: 85-265 VAC CRI:80;CCT:6500K Life time: 40,000-50,000 Hours
PF:0.95
EXIT LED c/w 2 hours battery pack backup, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.
Wiring point consist of 2x2.5sqmm PVC + 2.5sqmm PVC E and conduit (Each point does not exceed 10m), work
should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

Electrical Substation works


SUBSTATION
Supply, delivery, installation, testing and commissioning of DROP OUT FUSE for Main incoming Feeder in
Utility Station, work should be done as per design, drawing, specification of relevant chapter and accepted
by the Engineer.:
Rated Voltage(Nominal) : 12KV
Number of Phase 3
System frequency : 50Hz

Supply, delivery, installation, testing and commissioning of LIGHTNING ARRESTER for Main incoming
Feeder in Utility Station, work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.:
Rated Voltage(Nominal) : 12KV
Number of Phase 3
System frequency : 50Hz

Supply, delivery, installation, testing and commissioning of HT Cabling between HT Switchgear in Utility
Station and HT Switchgear in PTB Building and control tower, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

4 sets of 3x185mmsq 1C CU/XLPE/AWA/PVC 11KV power distribution cable in underground cable duct
linking from HT panel in Main 11KV Utility Station to HT panel in the PTB building and control tower. It shall
also include pilot cable, cable support, terminations, mounting, labelling, associated accessories and building
works necessary to provide the complete system as specified and complying with relevant codes.

HT (11KV) SWITCHGEAR (VCB) FOR INCOMING FEEDER(MAIN):


Supply, delivery, installation, testing and commissioning of (MAIN HT SW/BD) 12KV Incoming Feeder Air
Insulated Switchgears c/w Vacuum Circuit Breaker, protection relays including all Airport Operation
Readiness Trials. It shall also include BMS interfacing modules, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the complete
system as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

HT (11KV) SWITCHGEAR (VCB)FOR OUTGOING FEEDER:


Supply, delivery, installation, testing and commissioning of (MAIN HT SW/BD) 12KV Incoming Feeder Air
Insulated Switchgears c/w Vacuum Circuit Breaker, protection relays including all Airport Operation
Readiness Trials. It shall also include BMS interfacing modules, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the complete
system as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
HT (11KV) SWITCHGEAR (VCB)FOR INCOMING:
(UTILITY STATION TO PTB BUILDING, UTILITY STATION TO CONTROL TOWER AND AGL TO
CONTROL TOWER)
Supply, delivery, installation, testing and commissioning of (MAIN HT SW) 12KV Incoming Feeder Air
Insulated Switchgears c/w Vacuum Circuit Breaker, protection relays including all Airport Operation
Readiness Trials. It shall also include BMS interfacing modules, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the complete
system as specified and complying with relevant codes, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

TRANSFORMER

2000kVA THREE PHASE DRY TYPE TRANSFORMER(PTB)


Supply, delivery, installation, testing and commissioning of dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV
& 0.24 KV indoor type distribution transformer of DYN11 vector group having percentage impedance 4-
6.5%, basic impulse insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer,
complete with two windings of high conductivity copper, earthing terminals, temperature sensor with
thermometer, thermostat controlled blower fan (if required), lifting lugs, data plate etc. complete as required with
maximum 600C temperature rise and suitable for operation at
400 C ambient temperature manufactured & tested or equivalent approved by the Engineering-in-Charge in
accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

2500kVA THREE PHASE DRY TYPE TRANSFORMER(UTILITY STATION)


Supply & installation of Following type dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV & 0.24 KV indoor
type distribution transformer of DYN11 vector group having percentage impedance 4-6.5%, basic impulse
insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer, complete with two
windings of high conductivity copper, earthing terminals, temperature sensor with thermometer, thermostat
controlled blower fan (if required), lifting lugs, data plate etc. complete as required with maximum 600C
temperature rise and suitable for operation at 400 C ambient temperature manufactured & tested and approved
by the Engineering-in-Charge in accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done
as per design, drawing, specification of relevant chapter and accepted by the Engineer.

2000kVA THREE PHASE DRY TYPE TRANSFORMER(UTILITY STATION)(STEP UP)


Supply, delivery, installation, testing and commissioning of dry type cast resin 3-phase, 50Hz, 0.415 KV/11KV
indoor type distribution transformer having percentage impedance 4-6.5%, basic impulse insulation level 75
KV, HV & LV bushings, manual 5 position standard tap changer, complete with two windings of high conductivity
copper, earthing terminals, temperature sensor with thermometer, thermostat controlled blower fan (if
required), lifting lugs, data plate etc. complete as required with maximum 600C temperature rise and suitable for
operation at 400 C ambient temperature manufactured & tested and approved by the Engineering-in-Charge in
accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
500kVA THREE PHASE DRY TYPE TRANSFORMER(CONTROL TOWER)
Supply & installation of Following type dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV & 0.24 KV indoor
type distribution transformer of DYN11 vector group having percentage impedance 4-6.5%, basic impulse
insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer, complete with two
windings of high conductivity copper, earthing terminals, temperature sensor with thermometer, thermostat
controlled blower fan (if required), lifting lugs, data plate etc. complete as required with maximum 600C
temperature rise and suitable for operation at 400 C ambient temperature manufactured & tested by Trafo-Union
(Germany) /Trihal (France)/ Alstom (EU)/Thesar (Italy) or equivalent approved by the Engineering-in-Charge in
accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

315kVA THREE PHASE DRY TYPE TRANSFORMER (CONTROL TOWER)


Supply & installation of Following type dry type cast resin 3-phase, 50Hz, 11KV/0.415 KV & 0.24 KV indoor
type distribution transformer having percentage impedance 4- 6.5%, basic impulse insulation level 75 KV,
HV & LV bushings, manual 5 position standard tap changer, complete with two windings of high conductivity
copper, earthing terminals, temperature sensor with thermometer, thermostat controlled blower fan (if
required), lifting lugs, data plate etc. complete as required with maximum 600C temperature rise and
suitable for operation at 400 C ambient temperature manufactured & tested by Trafo-Union (Germany) /Trihal
(France)/ Alstom (EU)/Thesar (Italy) or equivalent approved by the Engineering-in-Charge in accordance
with NEMA / IEC / VDE / BS / JIS standards, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

315kVA THREE PHASE DRY TYPE TRANSFORMER STEP UP (CONTROL TOWER)


Supply, delivery, installation, testing and commissioning of dry type cast resin 3-phase, 50Hz, 0.415KV/11KV
indoor type distribution transformer of DYN11 vector group having percentage impedance 4-6.5%, basic
impulse insulation level 75 KV, HV & LV bushings, manual 5 position standard tap changer, complete with two
windings of high conductivity copper, earthing terminals, temperature sensor with thermometer, thermostat
controlled blower fan (if required), lifting lugs, data plate etc. complete as required with maximum 600C
temperature rise and suitable for operation at 400 C ambient temperature manufactured & tested and approved
by the Engineering-in-Charge in accordance with NEMA / IEC / VDE / BS / JIS standards, work should be done
as per design, drawing, specification of relevant chapter and accepted by the Engineer.

GENERATORS

Supply, delivery, installation, testing and commissioning of 1600 KVA 400 / 230 V, 3-phase, 50 Hz. air/water
cooled, floor mounted, indoor type following continuous capacity (Prime Power) electric generating set
suitable for tropicalized country complete with four stroke, 1500 rpm, diesel engine with all standard accessories,
viz. 12/24 volt DC battery & auto battery charger with ammeter, radiator assembly, oil & fuel pump, auto
speed governor, air cleaner, fuel & oil tank, fuel level & oil pressure gauge, RPM & hour meter, exhaust silencer,
vibration isolator, mounting steel base frame etc including a safety & protection device viz. auto shut off with
indicators for overload, over & under voltage high temperature, low oil pressure, over speed, low fuel level etc.
coupled with brush less, self excited alternator having control panel with auto voltage regulator, voltmeter
& ammeter with selector switch, frequency meter and work should be done as per design, drawing, specification
of relevant chapter and accepted by the Engineer.
Supply, delivery, installation, testing and commissioning of 1000 KVA 400 / 230 V, 3-phase, 50 Hz. air/water
cooled, floor mounted, indoor type following continuous capacity (Prime Power) electric generating set
suitable for tropicalized country complete with four stroke, 1500 rpm, diesel engine with all standard accessories,
viz. 12/24 volt DC battery & auto battery charger with ammeter, radiator assembly, oil & fuel pump, auto
speed governor, air cleaner, fuel & oil tank, fuel level & oil pressure gauge, RPM & hour meter, exhaust silencer,
vibration isolator, mounting steel base frame etc including a safety & protection device viz. auto shut off with
indicators for overload, over & under voltage high temperature, low oil pressure, over speed, low fuel level etc.
coupled with brush less, self excited alternator having control panel with auto voltage regulator, voltmeter
& ammeter with selector switch, frequency meter and work should be done as per design, drawing, specification
of relevant chapter and accepted by the Engineer.

TP MCCB of required rating for overload & instantaneous short circuit release , auto start & auto change
over to load within 10 sec during normal power failure and auto stop & auto change over to normal supply within
5 minutes after restoration of normal power supply, indicator for 3 Phase ON-OFF - Trip etc including
maintenance tools, 3 sets of detailed technical catalogues & maintenance manual. Manufactured, assembeled
and tested in accordance with NEMA / IEC / VDE / JIS standards, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

The generating set shall be assembled & tested in USA/Japan/EU countries. The major components like
engine,alternator, ATS, canopy shall also be manufactured and tested in USA/ Japan/ EU Countries &
accepted/approved by the Engineer and work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the cabling works with 1C-300 sqmm, NYY/XLPE cable from the standby generating set to control
panel as specified and work should be done as per design, drawing, specification of relevant chapter and accepted
by the Engineer.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the 20,000 litres underground fuel storage tank of capacity as specified c/w level indicators, fuel
pipes, vent pipes, reinforcement concrete pit, maintenance manhole and all necessary safety and control devices as
specified and work should be done as per design, drawing, specification of relevant chapter and accepted
by the Engineer.

Supply, delivery and installation of reinforced concrete re-fuelling pit c/w chequer plate cover, work should be
done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.
Supply, delivery, installation, testing and commissioning 250 KVA AVR for Fire
Fighting Building and work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.
LT Distribution Board

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following LT Switchboards. It shall also include protection relays, surge arrestors, electrical & signal
cabling, cable support, terminations, mounting, labelling, associated accessories and building works necessary to
provide the complete system as specified and complying with relevant codes, work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.
LT-4000A(Type tested assembly):
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor mounting type
completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard drawn electrolytic copper bus bars
(TPN+50%E) placed on porcelain insulator. Including cable color coding, cable lugs, Cable gland, nut, bolts and
washer and modern locks.The board is designed and constructed in accordance with BNBC-2014 & IEEE
Electrical wiring.And shall have type test certificate of switchgear from reputable international laboratory
(KEMA, ASTA OR ASIFA shall be submitted at the time of technical submission.
The switchgear shall include the following components: INCOMING:
2 No. 4000A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 4 Nos. Current transformer,
ratio 4000/5A with suitable accuracy and burden.
4 Nos. Ammeter scaled 0-4000A.
2 No. Voltmeter scaled 0-600V with selector switch. 4 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No. 3200A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 1 No. 1000A 35KA, 415V,
50Hz, TP ACB with Necessary controlling & protection option. 1 No. 800A 35KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip.
4No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 250A 25KA, 415V, 50Hz, TP
MCCB with thermal over load & magnetic trip. 1 No. 160A 25KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 1 set of control MCB.

LT-3200A(Type tested assembly):


Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor mounting type
completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard drawn electrolytic copper bus bars
(TPN+50%E) placed on porcelain insulator. Including cable color coding, cable lugs, Cable gland, nut, bolts and
washer and modern locks.The board is designed and constructed in accordance with BNBC-2014 & IEEE
Electrical wiring.
The switchgear shall include the following components: INCOMING:
2 No.3200A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 4 Nos. Current transformer,
ratio 3200/5A with suitable accuracy and burden.
4 Nos. Ammeter scaled 0-3200A.
2 No. Voltmeter scaled 0-600V with selector switch. 4 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1No. 3200A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 1 No. 2000A 35KA, 415V,
50Hz, TP ACB with Necessary controlling & protection option. 2 No.1000A 35KA, 415V, 50Hz,TP ACB with
Necessary controlling & protection option. 1No.800A 35KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip.
1No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 1No.400A 35KA, 415V, 50Hz, TP
MCCB with thermal over load & magnetic trip. 5 No. 250A 25KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 1 No. 125A 25KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 1 set of control
MCB.
LT-1600A(TTA):
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding, cable
lugs, Cable gland, nut, bolts and washer and modern locks.The board is designed and constructed in accordance
with BNBC-2014 & IEEE Electrical wiring.And shall have type test certificate of switchgear from
reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of technical
submission.
The switchgear shall include the following components: INCOMING:
2 No.1600A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option.
1 No.1000A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option.
6 Nos. Current transformer, ratio 1600/5A with suitable accuracy and burden. 6 Nos. Ammeter scaled 0-1600A.
3 No. Voltmeter scaled 0-600V with selector switch. 6 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1 No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 7 No. 250A 25KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 1 No. 160A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 1 set of control MCB.

LT-800A(TTA):
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 8000A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding, cable
lugs, Cable gland, nut, bolts and washer and modern locks.The board is designed and constructed in accordance
with BNBC-2014 & IEEE Electrical wiring.And shall have type test certificate of switchgear from
reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of technical
submission.
The switchgear shall include the following components: INCOMING:
2No.800A 65KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option. 4 Nos. Current
transformer, ratio 1600/5A with suitable accuracy and burden.
4Nos. Ammeter scaled 0-1600A.
2 No. Voltmeter scaled 0-600V with selector switch. 4 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1 No.630A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 250A 25KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 2 No. 160A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 4 No. 100A 25KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 1 set of control MCB.

PFI Plant
1500KVAR PFI Plant

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

1200KVAR PFI Plant


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

380 KVAR PFI Plant

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

190 KVAR PFI Plant

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Automatic PFI Plant. It shall also include PFC relays, electrical & signal cabling, cable support,
terminations, mounting, labelling, associated accessories and building works necessary to provide the
complete system as specified and complying with relevant codes, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

Distribution Boards
Distribution Boards (PTB)-MDB-800A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 800A)(Type tested assembly) . It shall also
include protection relays, electrical & signal cabling, cable support, terminations, mounting, labelling,
associated accessories and building works necessary to provide the complete system as specified and
complying with relevant codes, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 800A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.The board is designed and constructed in
accordance with BNBC-2014 & IEEE Electrical wiring.And shall have type test certificate of switchgear
from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of technical
submission.
INCOMING:
1 No. 800A 50KA, 415V, 50Hz, TP ACB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 800/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-800A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
8No.250A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4 No. 200A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 160A 35KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 2 No. 100A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 1 set of control MCB.

MAIN DISTRIBUTION BOARD-630A


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 630A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 630A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1 No. 630A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 630/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-630A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1No.250A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
1No. 160A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 100A 35KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 2 No. 63A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip.
2 No. 32A 25KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 1 set of control MCB.

MAIN DISTRIBUTION BOARD-400A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 400A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1 No. 400A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 400/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-400A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No.100A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4No. 63A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 40A 25KA, 415V, 50Hz,
TP MCCB with thermal over load & magnetic trip. 5 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over
load & magnetic trip.
5 No. 20A 16KA, 415V, 50Hz,DP MCB with thermal over load & magnetic trip. 1 set of control MCB.

MAIN DISTRIBUTION BOARD-250A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 250A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1 No. 250A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 250/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-250A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
1No.100A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4No. 63A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 40A 25KA, 415V, 50Hz,
TP MCCB with thermal over load & magnetic trip. 5 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over
load & magnetic trip.
5 No. 20A 16KA, 415V, 50Hz,DP MCB with thermal over load & magnetic trip. 1 set of control MCB.

FLOOR DISTRIBUTION BOARD-250A


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 250A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.
The switchgear shall include the following components: INCOMING:
1 No. 250A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
2Nos. Current transformer, ratio 250/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-250A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No.200A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
2No. 100A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 63A 25KA, 415V,
50Hz, TP MCCB with thermal over load & magnetic trip. 4 No. 50A 25KA, 415V, 50Hz, TP MCCB with
thermal over load & magnetic trip. 4 No. 32A 16KA, 415V, 50Hz, TP MCCB with thermal over load &
magnetic trip. 4 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over load & magnetic trip.
2 No. 32A 16KA, 415V, 50Hz,DP RCBO
1 set of control MCB.

FLOOR DISTRIBUTION BOARD-100A-160A

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following MAIN Distribution Switchboards( RAT 160A)(TTA) . It shall also include protection
relays, electrical & signal cabling, cable support, terminations, mounting, labelling, associated accessories
and building works necessary to provide the complete system as specified and complying with relevant
codes, work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.
Made of 16 SWG sheet steel clad with powder coated, dust and vermin proof, free standing, floor
mounting type completely factory assembled 415 V, 50Hz, LT Switchgear panel having 400A hard
drawn electrolytic copper bus bars (TPN+50%E) placed on porcelain insulator. Including cable color coding,
cable lugs, Cable gland, nut, bolts and washer and modern locks.And shall have type test certificate of
switchgear from reputable international laboratory (KEMA, ASTA OR ASIFA shall be submitted at the time of
technical submission.
The switchgear shall include the following components: INCOMING:
1No. 160A 50KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
3Nos. Current transformer, ratio 160/5A with suitable accuracy and burden. 3 Nos. Ammeter scaled 0-160A.
3 No. Voltmeter scaled 0-600V with selector switch. 3 Nos. Phase indication lamp R / Y / B.
1 set of control MCB. OUTGOING:
2No.63A 40KA, 415V, 50Hz, TP MCCB with Necessary controlling & protection option.
4No. 40A 35KA, 415V, 50Hz, TP MCCB with thermal over load & magnetic trip. 8 No. 32A 16KA, 415V, 50Hz,
TP MCCB with thermal over load & magnetic trip. 4 No. 32A 16KA, 415V, 50Hz, DP MCB with thermal over
load & magnetic trip. 1 set of control MCB.

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for the
following Sub Distribution Switchboards(Type tested assembly)
. It shall also include protection relays, electrical & signal cabling, cable support, terminations, mounting,
labelling, associated accessories and building works necessary to provide the complete system as specified in
drawing and complying with relevant codes, work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

DB-Type-01(As per Drawing)


DB-Type-02(As per Drawing)
DB-Type-03(As per Drawing)
DB-Type-04(As per Drawing)
DB-Type-05(As per Drawing)
DB-Type-06(As per Drawing)
CABLE FOR DISTRIBUTION SYSTEM (work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.)
5X4x1C-500 sq. mm (XLPE) with 3x1C-300 sq. mm (BYA) ECC
7X4x1C-500 sq. mm (XLPE) with 3x1C-300 sq. mm (BYA) ECC
5X4x1C-400 sq. mm (XLPE) with 3x1C-240 sq. mm (BYA) ECC
4x4x1C-500 sq. mm (XLPE) with 2x1C-300 sq. mm (BYA) ECC
4x1C-400 sq. mm (XLPE) with 1C-240 sq. mm (BYA) ECC
2X4x1C-300 sq. mm (XLPE) with 1C-300 sq. mm (BYA) ECC
4x 1C-300 sq. mm (XLPE) with 1C-150 sq. mm (BYA) ECC
4x1C-120 sq. mm (XLPE) with 1C-70 sq. mm (BYA) ECC
4x1C-95 sq. mm (XLPE) with 1C-50 sq. mm (BYA) ECC
4x1C-70 sq. mm (XLPE) with 1C-35 sq. mm (BYA) ECC
4 x 1C-50 sq. mm (XLPE) with 1C-25 sq. mm (BYA) ECC
4x 1C-35 sq. mm (XLPE) with 1C-16 sq. mm (BYA) ECC
4x 1C-25 sq. mm (XLPE) with 1C-16 sq. mm (BYA) ECC
4x1C-16 sq. mm (XLPE) with 1C-16 sq. mm (BYA) ECC
Cable Support (work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.)
300mmx100mm cable trunking
150mmx100mm cable trunking
75mmX50mm cable trunking
6x700mm Cable Lader
450mmx100mm cable Tray
2x600mm Cable Tray
2x300mm Cable Tray
150mm Dia PVC Pipe
UPS

Supply, delivery, installation, testing and commissioning of the following unit of complete IGBT
uninterruptiable power supply system c/w all necessary control and mimic panels including all Airport
Operation Readiness Trials. It shall also include internal static bypass circuitry, isolation transformer at the
output, earthing, BMS interfacing modules, electrical & signal cabling, cable support, terminations, mounting,
labelling, associated accessories and building works necessary to provide the complete system as specified
and complying with relevant codes, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

UPS-U1 (120kVA)

Supply, delivery, installation, testing, commissioning, including all Airport Operation Readiness Trials for the
following Sub Distribution Switchboards in Main Terminal. It shall also include protection relays, BMS
interfacing modules, electrical & signal cabling, cable support, terminations, mounting, labelling,
associated accessories and building works necessary to provide the complete system as specified and
complying with relevant codes, work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

EDB-UPS

Supply, delivery, installation, testing, commissioning, including all Airport Operation Readiness Trials for
the following Distribution Boards in Main Terminal. It shall also include protection relays, BMS
interfacing modules, electrical & signal cabling, cable support, terminations, mounting, labelling,
associated accessories and building works necessary to provide the complete system as specified and
complying with relevant codes, work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.

DB TYPE : 07
DB TYPE : 08
2 x 25sqmm 1C FR + 16sqmm 1C PVC E

ADDRESSABLE FIRE DETECTION & ALARM SYSTEM


Addressable Fire Alarm Control Panel (FACP)

Supply and installation of Microprocessor based Fire Alarm Control Panel (FACP) which shall be capable to
handle at least 127 devices (Up to 127 Detector & Modules, plus 127 analog sounder
bases, for a total of 254 points possible per loop) per loop.

The FACP shall provide the following features:


4 No of Loop SLC
4 No of NAC Ckt.
Large 8-line x 40-character LCD display (320 char.)
Minimum loop length 1.6km
Built-in Alarm, Trouble and Supervisory relays.
Soft address function
History File
Easy to add/remove devices
Automatic day/night sensitivity adjustment
Status LEDs to easily identify system status
Auto-learn feature, Fire Drill test function, Walk Test function
Capable to networking with other FACP and Repeater Panel
Built-in in battery charger
Battery capacity: as per battery calculation (shall be done by Vendor)
Approvals: UL Listed, FM approved.
Addressable Fire Alarm Repeater Panel (FARP)
Supply & installation of addressable type repeater panel for mimicking Main Fire Alarm
Control Panel data.
The FARP shall provide the following features:
320 character liquid crystal display (8 line x 40 character)

LED indicators for Fire, Supervisory Alarm, Pre- Alarm, Fire Output Active, Power On, On Test, Panel Sounder
Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System
Trouble & NAC Trouble

Capable to networking with FACP


Approvals: UL Listed, FM approved.
External Power Supply
Supply and installation of External power supply unit with all other accessories from the same Manufacturer of
FACP. It shall be used for providing power to Notification
appliances.
The Power Supply shall provide the following features:
6 No of NAC Ckt.
Capacity: To power up to 10 Horn & Strobe per NAC Ckt.
Quadrasync provides panel wide synchronization of the same or multiple brands
Configurable output circuits (DIP switch sets options for each circuit)
Built-in in battery charger
Supports 7 - 55AH batteries
Approvals: UL Listed, FM approved.
Addressable Manual Call Point (MCP)
Supply and installation of addressable type manual call point like single action/double pull station complete
with back box and all other accessories and consumables.

The MCP shall provide the following features:


Bi-colored status LED indicates Standby and Alarm conditions
Address is programmable in EEPROM
Approvals: UL Listed, FM approved.
Addressable Optical Smoke Detector (SD)
Supply and installation of Microprocessor based addressable Optical Smoke Detector.
The SD shall provide the following features:
Detector sensitivity must be programmed in the control panel software
Sensitivity must be continuously monitored and reported to the panel.
Two built-in power/alarm LEDs
Non-directional smoke chamber
Approvals: UL Listed, FM approved.
Addressable Heat Detector (HD)
Supply and installation of Microprocessor based addressable Fixed temperature & rate of
rise thermal detector.
The HD shall provide the following features:
Rate of Rise temperature threshold = 15°F/Min
Adjustable threshold temperature = 135°F - 190°F
Detector sensitivity must be programmed in the control panel software.
Two built-in power/alarm LEDs
Approvals: UL Listed, FM approved.
Addressable Duct Detector (DD)
Supply and installation of Microprocessor based addressable Duct detector.
The DD shall provide the following features:
Detects and limits the spread of smoke throughout building HVAC ducts
No screens or filters to clean
Approvals: UL Listed, FM approved.
Conventional Electronic Strobe with Sounder
Supply and installation of conventional Electronic Strobe with Sounder for Visible &
Audible application which shall have field-selectable candela & volume settings
The Strobe with Sounder shall provide the following features:
Switch Selection for High or Low dBA
Switch Selection for 2400Hz or Mechanical Tone
Min. Sounder Output: 81dBA @ 10ft
Min. Candela Output: 15cd
Approvals: UL Listed, FM approved.
Addressable Input Module

Supply & Installation of Addressable input Module which shall be used in the field wiring to connect the to
additional devices (i.e. Fire Pump, Fire Pump Panel, Control Valves, Sprinkler Zone Control Valves, Duct
Detector, etc... ) with the Addressable FACP interfaces to make the system convenient as when as required.

The Input Module shall provide the following features:


The module shall be suitable for double address to the FACP on receiving both alarm &
fault signal form any electrical/electro mechanical.
Can be programmed to monitor Normally Open (NO) or Normally Closed (NC) contacts
Approvals: UL Listed, FM approved.
Addressable Output Module
Supply & Installation of Addressable type relay output module which shall be used in fire alarm system to
integrate with lift control systems, exhaust fan panel, fire door, HVAC, Escalator, Conveyer Belt, Access Control
Door, PA System, etc.
The Output Module shall provide the following features:
Provides two independently configurable Form C contacts per address
Programming is highly flexible providing 16 priority
states plus zoning capability
Approvals: UL Listed, FM approved.
Short Circuit Isolator (SCI)
Supply & Installation of Short Circuit Isolator
The SCI shall provide the following features:
Can be placed at any location on SLC loop
Checks the line for short circuit at power up. If the line is normal, the relay will be returned on. If a line short is
detected, the relay remains open
Approvals: UL Listed, FM approved.
Cabling & Conduit Works
Supply & installation of PVC insulated PVC sheathed copper conductor single / multicore FP (fire proof) cable
complete with PVC conduit or GI pipe. Conduit works
shall be complete with Bends, Tees, Junction box, etc.
i) 2x1.5mm2 (FR)+1.5AL (Foil) FP-200 c/w 20mm pVC conduit
ii) 2x2.5mm2 (FR)+1.5AL (Foil) FP-200 c/w 20mm pVC conduit
Fire Monitoring/SCADA System

Supply & Installation of Fire Monitoring System to represent fire device status in a graphical interface.
- Extensive logging of events and operations
- User friendly installation and configuration
- Monitoring Station(Desktop Computer) (including required interfacing devices & Software)
SEWAGE TREATMENT PLANT

Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant (STP) capacity 350
m3/day. The plant proposed shall be a common pump room in near of STP. The plant is proposed to be
installed in the ground accessible for future maintenance.

Nature of effluent-Domestic Sewage( Toilet: Black & Grey Water) from each tiolet of
individual building use to STP
Daily average flow : 350 m3/day
Nature of effluent - Sewage
Influent Characteristics
pH - 7.5 - 8.5
BOD5 - upto 200-250 Mg/L
S. Solids - 200- 400 Mg/L
COD - upto 400-500 Mg/L
Oil & Grease - 30 Mg / L
Effluent discharge standard after treatment
pH - 6.5 - 8.5
BOD - Less than 10 mg/L
TSS - Less than 10 mg/L
COD - Less than 75 mg/L
Oil & Grease - < 2 Mg / L
Residual Chlorine- Less than 10 mg/L
Colifrom- Less than 100 counts/100 ml (desired nil)
Sewage treatment plant shall include the following items
a). Screen Chamber / Oil and Grease Chamber
b). Equalization / Collection Tank
c). Aeration TANK
d). Secondary Settling tank
e).Treated Effluent Tank
f). Sludge Holding Tank
g). Filtration through MGF (Multigrade Filter) & ACF (Activated Carbon Fibres)
h). Air Blowers, Pumps & equipment
i). Piping, valves etc
j).Electrical Panel & Cabling
k).Common plant room adjacent to STP.
l). All piping, valves & level indicator/controller etc. within plant room.

Supply, installation, testing & commissioning of one nunber Stainless Steel Perforated Screen with suitable
lifting arrangement mechanically (size 600mm wide x 1000mm high approx) Barsizing will be 40mm x 6mm &
Bar spacing should be min 15mm

Supply, installation, testing & commissioning of electronic type level indicator and controller for automatic
operation of the system with high/low level alarm complete with
auxillary NO/NC (Normally Open/Normally Closed) Contacts

Supply, installation, testing & commissioning of non clogging type pumps, having CI casing & SS shaft,
bronze impeller complete with all accessories, motor of required capacity. Delivery header with isolation
valve/NRV etc, pressure gauge on delivery line with isolation cock level controller with wiring to
control the level of sump automatically. Pump shall have following duty :
i) Submersible Sump Pumps for equilisation tank/Sewage lifting pump (2Nos.-1working
& one standby) :-
Flow rate (each) = 20 m3 / hr
Head = 10-15 Meter
ii) Submersible Solid handling Pumps (2 Nos.- 1 working + 1 standby)
Flow rate (each) = 4 m3/hr
Head = 5-10 Mts

iii) Sludge Recirculation Pumps (2Nos.-1working & one standby) :-


Flow rate (each) = 4 m3 / hr
Head = 5-10 Mtr
Air diffusion system shall include the following:

Twin type rotary air blowers (1working & 1 standby) capable of delivering 200 m3/hr (each) or required
capacity of free air at 0.55kg/cm2 driven through “V” belt or directly coupled through flexible coupling to a TEFC
("Totally Enclosed, Fan Cooled") motor of suitable HP Suitable for 415±10% volts, 3 phase, 50 cycles a/c supply

Air piping shall comprise of pipes droppers/laterals with MS (epoxy coated) Header complete with all
fittings such as tees, crosses, plugs, sockets, elbows, reducers, supports
& clamps, puddle flanges etc cutting chases & making good.
Non clog type air dispersion system capable of handling 3-5 cfm or required capacity of air with oxygen transfer
efficiency of 3-4% per/meter water depth. Air dispersion grid
shall be assembled in modular form so that they can be replaced / repaired
Fine bubble diffusers required Nos
i) For Equalization / Collection Tank -1 Nos.
ii) For Sludge Holding Tank - 1 No.
iii) Aeration Tank- 1Nos.
Air dispersion system shal lbe provided for Equalisation Tank, Sludge holding Tank and
Aeration Tank.
Providing and fixing all piping (as described below) and isolation control valves form
making thes ystem complete.
SS 304 : Submerged air piping
MS Epoxy : Air piping
PVC piping: Pumped effluent & tank over flow pipe line
Supply, installation, testing and commissioning of circular floating type media to be
installed in Aeration Tank (1Nos.) and PVC tube deck settling media to be installed in Secondary Settling Tank
along with suitable sludge removal arrangement.

Supplying, installing, testing & commissioning of filter feed water pumps CI Body, SS shaft, bronze Impeller
with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery
line. Isolation valve, stainer at suction. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c
supply

Capacity : 15 m3/hr.
Head : 15-20 meter
No. of Pumps (1 working + 1 standby)
Operation of pump shall be based on level controller proposed to be installed in tank as per site location. The
contractor to ascertain the Head required for pumps as per site
conditions and provide accordingly
Supplying, installing, testing and commissioning of FRP vessel filter with frontal piping
and associated valves and accessories. Filter shall be suitable for minimum working pressure of 5kg/cm2
and shall include media, standard fittings like pressure.
i) Multigrade pressure sand filter media
Flow rate : 15 cum/hr
Filteration velocity : 12 cum/hr/sqm
Filter Diameter : 1000 mm.
ii) Activated Carbon Filter
Flow Rate : 15 cum/hr
Filteration velocity : 12 cum/hr/sqm
Filter Diameter : 1000 mm
Contractor may be asked to alter the number of filters and pumps subject to any revision
to meet the desired capacities.

Supply, installation, testing & commissioning of water softening plant (FRP)for making up of water for cooling
tower and toilet flushing comprising of multiport valve with brine ejection and plastic piping complete with brine
tank with fitting & brine fitting filtering media and complete charge of cation exchange resine as given below
(incoming hardnes 350 PPM).

Water Flow : 15 m3/hr for 8 hr.


(Incomming Hardness 350mg/lit (Approx))
Working Pressure 3.0 Kg/Cum
Outgoing hardness less than 50 ppm
Water Softening plant as described above

Supply, installation, testing and commissioning of Filter Press of plate size 16"x16" plate with screw feed pumps
for required capacityas/requirment (1Working+1Standby), with interconnecting piping and poly dosing system
all complete.

Supply, installation, testing & commissioning of Booster pump with CI Body, SS shaft, Bronze Impeller with
mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line.
Isolation valve, stainer at suction. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c supply

i) For reuse for toilet Flashing


Capacity : 35 m3/hr.
Head : 80 meter
No. of Pumps (4 working + 1 standby)
ii) For Cooling Tower
Capacity : 5 M3/hr.
Head : 45 M
No. of Pumps (1 working + 1 standby)
Providing & fixing bypass line with arrangement of valve from equilization tank, tank to
out side sewer manhole/ for tanker connection.
Supply, installation, testing & commissioning of pH Meter, Electronic megnetic flow
meter in inlet & outlet of filtration system complete in all respect.
Supply, installation, testing and commissioning of Energy Meter for electrical panel of
STP complete in all respect.

Supply, installation, testing & commissioning of Dosing System. Horizontal centrifugal with PP/PVC impeller,
200 lph@6m head. Capacity 0-12 LPH, HDPE tank 500 ltrs.
Magnetic flow meter

Providing & fixing on line full bore type Magnetic flow meter with preamplifier & microprocessor based
electronic flow meter mounted in plumbing plant room electrical control panel with the following features.
Monitoring the total flow, Flow rate, etc. Including electrical wiring from preamplifier to microprocessor based
flow meter.
Complete with all type of Plumbing & Electrical connections, accessories, wiring, conduits & supports complete
with all respect. The signal from read out shall be 4-20 m.amps to be received as BAS.

a) Suitable for flow rate of sewage feed pump to SBR tank


ELECTRICAL INSTALLATION FOR STP

Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre
fully compartmentalised fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top
as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per
specifications with 2 coats of redoxide primer and final approved shade of powder coated paint. 2 Nos. earthing
terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. Lifting hooks shall also be provided in
case of large panels. Approval shall be taken for each panel before fabrication. Quoted rates shall be inclusive
of cables(in accordance to specification) with earthing from panel to each motor / equipment.

a. All MCCBs/MCBs shall be of 15KA breaking capacity and suitable for motor duty
application.
b. All motor starters shall be provided with Automatic level controller
c. DOL starters shall be used for motors below 10 HP and Star-Delta Starters for other
motors .
d. Provision shall be made for providing potential free contacts to all pumps starters
MCC for all STP equipments/pumps as described in sub head II

Water Treatment Plant

Contractor must include all items that are necessary and essential to provide a complete working plant to the
satisfaction of consultant/engineer in charge. No extra payabe later. Any deficiency/improvement in this offer
(specs/boq) must be brought to the knowledge of the consultant/engineer in charge, now-before offering the boq
given hereafter is only for the purpose assessing the overall costing of the project and will be used for arriving at
the payment schedule to the contractor for actual and approved work done. All Quoted Equipments and Pumps are
inclusive of all taxes.Design, Engineering, and providing all equipment /machinary at site, installation and
commissioning of equipments/ electricals/ piping exclusive of all types of taxes and duties.

Raw Water Treatment Plant


Supply, fitting, fixing of water treatment plant including below items/components
Raw Water Feed Pump :

Supplying, installing, testing & commissioning of filter feed water pumps CI Body, SS shaft, bronze Impeller
with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery
line. Isolation valve, stainer at suction.

System component and specification: vertical multi-stage centrifugal pump complete


with accessories, motor insulation class f (2 duty, 2 standby)
Operation of pump shall be based on level controller proposed to be installed in tank as
per site location. The contractor to ascertain the Head required for pumps as per site conditions and
provide accordingly
Each pump capacity = 41 m3/hr. & Head, H=15-40 m

Control function and control devices : Floatless switch control at raw water tank
- low level alarm
- low level stop raw water feed pumps
- low level start deep well pump
- high level stop deep well pump
- high level alarm

Supplying, installing, testing and commissioning of FRP vessel filter with frontal piping and
associated valves and accessories. Filter shall be suitable for minimum working
pressure of 5kg/cm2 and shall include media, standard fittings like pressure.

Iron Remover Filter (IRF-01 & IRF-02)

System component and specification: pressure sand filter with multiport vavle, automatic
air relief valve ,pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller

Multigrad Pressure Sand Filter (MF-01 & MF-02)

System component and specification: pressure sand filter with multiport vavle, automatic
air relief valve ,pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller

Activated Carbon Filter (ACF-01 & ACF-02)

System component and specification: activated carbon filter with multiport valves,
automatic air relief valve, pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller
Water Softening Plant

Supply, installation, testing & commissioning of water softening plant (FRP) for making up of water for toilet
washing and other purpose comprising of multiport valve with brine ejection and plastic piping complete with
brine tank with fitting & brine fitting, filtering media and complete charge of cation exchange resine.
Automatically operated by plc controller

Each pump capacity, Q = 41 m3/hr. & Head, H=40 m


Working Pressure 3.0 Kg/Cum
Automatically operated by plc controller
Cartige Filter

Cartige Filter (CF-01 & AC-02)

System component and specification: activated carbon filter with multiport valves,
automatic air relief valve, pressure gauge, drain valve and necessary connections
Each pump capacity, Q = 41 m3/hr. & Head, H=40 m
Automatically operated by plc controller
Chemical Storage Tank (CST- 01)
System component and specification: polyethylene tank with cover, level indicator, drain
connection and accessories for metering pump installation
Volume = 200 Liters
Chlorine Storage Tank (CST- 02)
System component and specification: polyethylene tank with cover, level indicator, drain
connection and accessories for metering pump installation
Volume = 200 Liters

Chemical Feed Pump for CST-01 (CFP - 01)

System component and specification: diaphragm metering pump adjustable stroke type, non- corrosive casing
complete with foot valve, injection check valve and accessories

Each Pump Capacity = 10 L / h & H = 6.5 Bar and V/Ø/Hz: 220/1/50

Automatically operated by flow switches


Chlorine Feed Pump for CST-02
(CFP - 01)

System component and specification: diaphragm metering pump adjustable stroke type, non- corrosive casing
complete with foot valve, injection check valve and accessories

Each Pump Capacity = 10 L / h & H = 6.5 Bar

V/Ø/Hz: 220/1/50
Automatically operated by flow switches
Chemical Mixer for Chemical and Chlorine Storage Tank (MX - 01 & MX - 02)
System component and specification: stainless steel shaft and impeller completed motor
insulation class f
Capacity for 200 Liters HDPE Tank
RPM: 1600
V/Ø/Hz: 220/1/50
Manually Operated
Cold Water Booster Pump Set
Package constant pressure booster pump consists of 2 pumps sized for 50% and 50%
of the total system flow rate, complete with diaphragm pressure tank, regulating valve, control devices and control
panel from manufacturer
(1 set duty, 1 set standby)

Each Pump Capcity: 20 m3/hr. x 4 nos in set Head = 78 m


Diaphragm Tank Volume > 400 L
Control details: floatless sensor control at each water tank
- very low level alarm
- low level stop booster pumps (cwbp-01, 02)
- low level stop soft water feed pumps (sffp-01, 02)
- high level stop raw water feed pumps(rwfp-01,02)
- very high level alarm Booster pump set
- automatic operation by discharge pipe pressure sensor & control system
- remote outputs to bas for on/off/fault status
- lead pump shall be alternated periodically by the control system

Hot Water Feed Pump :

Supplying, installing, testing & commissioning of hot water centrifugal pumps, CI Body, SS shaft, bronze
Impeller with mechanical seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on
delivery line. Isolation valve, stainer at suction.

System component and specification: vertical multi-stage centrifugal pump complete


with accessories, motor insulation class f (2 duty, 2 standby)
a).Hot water Heating pump = 100 liter/min. & Head, H=5 meter
b). Hot water Circulating pump = 225 liter/min. & Head, H= 11 meter
c). Hot water Heating pump(FS) =80 liter/min. & Head, H=5 meter
b).Hot water Circulating pump(FS) =25 liter/min. & Head, H= 5 meter
DEEP TUBE WELL WITH ALL FITTING AND FIXTURE INCLUDING PUMP
ELECTRICAL CABLE WORKS
Electrical works shall be complete with supply and installation of all cables, conduit,
distribution board etc. as per direction of the Engineer.

PDB DEPOSIT WORK


PDB. Deposit work for Extension of Duel 11K.V. Express Feader line from PDB Sub-
station to Airport Side.
Sub-Total (Building Works)

HVAC SYSTEM
WATER CHILLER UNIT :
WATER COOLED CENTRIFUGAL CHILLER

Supply, installation, testing and commissioning of High Efficiency Water Cooled Screw/Centrifugal type Chiller
with oil free magnatic bearing type of multiple semi hermetic screw/centrifugal compressor having capacity not
less than 1,407 KW (400 US RT) when 4,884 L/min (1290 US GPM) of condenser water entering at 32°C
(89.6°F) and leaving at 37°C (98.6°F).

The Chiller shall be shell and tube water cooled condenser, shell and tube flooded evaporator with insulation, flow
switches at chiller and condenser water pipe, vibration isolators, integral refrigerant piping and wiring, accessories
as required and called for, automatic and safety controls mounted in central console panel and all mounted on a
steel frame complete as per specifications.

Motor shall be suitable for 400±10%V, 50 Hz, 3 phase AC supply. Refrigerant used shall be Ozone friendly R-
134a as detailed in specifications. Chiller shall have electronic expansion valve, serial card for backnet, input
remote demand limit, touch visual display, etc. All components including compressor shall be from the same
The chilled water capacity shall be 4,4034 L/min (1066 US GPM) when entering at 12°C (53.6°F) and leaving at
30°C44.6°F. The full load efficiency at rated condition of the chiller shall not be more than 0.50 kW/RT.
AHRI/Eurovent Certified rating report must be submitted to prove both full load kW/RT.

The cooler and condenser shall have water side fouling factor of Evaporator 0.000102 hr- ft2-oF/Btu and
Condenser 0.000250 hr-ft2-oF/Btu. The water pressure drop in the cooler and condenser water shall not exceed 20
ft WG. Chiller shall be capable to have smooth operation at minimum load of 20%.

The unit shall be complete with microprocessor based control panel with graphic display panel and also c/w open
protocol which is compatible to any building management system. The capacity control shall be fully automatic
and based on chilled water outlet temperature. Vibration isolator shall be included with each unit.

Each machine shall be completed with integrated factory fitted inbuilt inverter for proper capacity control and to
reduce starting inrush current. Each unit shall be
assembled, wired, tested and factory charged. Details as per Technical Specification.
Capacity of Chiller : 1,407 KW (400 US RT)
COOLING TOWER :

Supply, installation, testing and commissioning of enclosed type, axial-flow induced draft cross flow rectangular
type cooling tower. It shall be completed with make-up water valve, float assembly, access door, motor, fan ( FAN
CAPACITY 15 KW TYPE OF FLOW AXIAL, eliminators, steel support, ladder etc. Cooling Tower details along
with accessories shall comply in accordance with specification including Immersion type temperature sensor and
other accessories The Cooling Tower having capacity of Cooling 1,920,000 KCAL/H(500 CRT) of water from
32°C (89.6°F) to 37°C (98.6°F) when
outside air wet bulb temperature is 24°C.The Cooling Tower shall be constructed of Fibre Glass Reinforced
Polyster (FRP) and galvanized Iron components. Drift loss shall not be more than 0.5% of water flow. The power
supply shall be 400V±10/3ph/50Hz. COOLING tower water flow rate 4,884 l/min (1290 US GPM) operation
weight 6250 kg.The cooling shall be CTI certified. Details as per Technical Specification.

Cooling Capacity : 4884 L/m (1290 US GPM)


FREE COOLING HEAT EXCHANGER
Supply and installation of free cooling plate type heat exchanger with standard
accessories as per following specification
Capacity: 1407 kW
Max. working prssure: 1000 kPa
CENTRIFUGAL PUMPS :

Supply, installation, testing and commissioning of end Suction, vertical discharge Centrifugal Pumps as per
following capacities and specifications. Each pump shall be complete with integrally coupled electrical motor of
appropriate capacity, flexible coupling, spacer unit, support base, mechanical seal, safety cover, spring isolator etc.
complete and all other standard components. Each pump shall be minimum 70% efficient and motor shall be
heavy duty type suitable to operate at 400C ambient temperature. The speed of the motor shall not exceed 1450
rpm. The supply power shall be 360v~440v/3ph/50Hz. Details as per Technical Specification.

Contractor will calculate the head loss calculation before place the order.
Chilled Water Pumps
Flow Capacity : 4034 L/min (1066 US GPM)
Total head: 47 Meter (150 ft.) PA
Condenser Water Pumps
Flow Capacity : 4884 L/m (1290 US GPM)
Total head: 19 Meter (150 ft.) PA
CHEMICAL DOSING UNIT :

Supply, installation, testing and commisioning of Chemical Dosing Unit (Pot Feeder) complete with necessary
chemicals for treatment of condenser water and chilled water in order to control growth of algae, bacteria,
biological componets and control of corrosion of pipe surfaces. Pot Feeder and chemicals for treatment of
condenser water and chilled water. Details as per Technical Specification.

Capacity 6500 US Gpm


AIR HANDLING UNIT (AHU)

Supply, installation, testing and commisioning of weather proof type, floor mounted, horizontal type, horizontal
discharge draw throw type Air Handling Unit. Each shall be constructed with 40mm thick insulated (Insulation
materials:PU) double skin panel with thermal barrier, outside power coated casing and shall be completed with
AIRFOIL type fan with external motor, variable frequency drive with pressure sensor, copper cooling coil with
aluminium fin, washable filter before coil, 85% cfficiency bag filter before coil, extended drain pan, vibration
isolator etc. Drain pan shall be constructed with stainless steel, tapered towards collection and shall be zero

AHU-1
Air flow Capacity : 50,600 m3/hr (29854 CFM)
Statics Pressure (S.P) : 1,144 PA
Entering Air Temparature : 27℃ DB & 20 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.5℃ WB
Chilled water flow rate : 1,151 LPM (304 US GPM)
AHU-2
Air flow Capacity : 50,400 m3/hr (29736 CFM)
Statics Pressure (S.P) : 1,078 PA
Entering Air Temparature : 27.5℃ DB & 20.3 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.4℃ WB
Chilled water flow rate : 1,221 LPM (323 US GPM)
AHU-3
Air flow Capacity : 41100 m3/hr (23838 CFM)
Statics Pressure (S.P) : 1,012 PA
Entering Air Temparature : 26.5℃ DB & 19.4 ℃ WB
Leavring Air Temparature : 13.6℃ DB &12.7℃ WB
Chilled water flow rate : 849 LPM
AHU-4
Air flow Capacity : 31000 m3/hr (17980 CFM)
Statics Pressure (S.P) : 1,012 PA
Entering Air Temparature : 26.5℃ DB & 19.4 ℃ WB
Leavring Air Temparature : 13.6℃ DB &12.7℃ WB
Chilled water flow rate : 849 LPM
AHU-5
Air flow Capacity : 32800 m3/hr (19024 CFM)
Statics Pressure (S.P) : 1,078 PA
Entering Air Temparature : 27.2℃ DB & 20.0 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.4℃ WB
Chilled water flow rate : 757 LPM
AHU-6
Air flow Capacity : 32700 m3/hr (18966CFM)
Statics Pressure (S.P) : 1,012 PA
Entering Air Temparature : 28.0℃ DB & 20.7 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 853 LPM
AHU-7
Air flow Capacity : 32700 m3/hr (18966CFM)
Statics Pressure (S.P) : 963 PA
Entering Air Temparature : 27.6℃ DB & 19.4 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.4℃ WB
Chilled water flow rate : 806 LPM
AHU-8
Air flow Capacity : 39700 m3/hr (23026CFM)
Statics Pressure (S.P) : 1,037 PA
Entering Air Temparature : 26.2.0℃ DB &19.1 ℃ WB
Leavring Air Temparature : 13.9℃ DB &12.9℃ WB
Chilled water flow rate : 738 LPM
AHU-9
Air flow Capacity : 35700 m3/hr (20706CFM)
Statics Pressure (S.P) : 1095 PA
Entering Air Temparature : 26.8℃ DB & 19.6 ℃ WB
Leavring Air Temparature : 13.9℃ DB &12.9℃ WB
Chilled water flow rate : 735 LPM
AHU-10
Air flow Capacity : 37700 m3/hr (21866CFM)
Statics Pressure (S.P) : 963 PA
Entering Air Temparature : 27.0℃ DB & 19.9 ℃ WB
Leavring Air Temparature : 13.6℃ DB &12.6℃ WB
Chilled water flow rate : 839 LPM
AHU-11
Air flow Capacity : 53200 m3/hr (30856CFM)
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 26.4℃ DB & 19.3 ℃ WB
Leavring Air Temparature : 13.8℃ DB &12.8℃ WB
Chilled water flow rate : 1051 LPM
AHU-12
Air flow Capacity : 38900 m3/hr (22562CFM)
Statics Pressure (S.P) : 1095 PA
Entering Air Temparature : 28.5℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 1078 LPM
AHU-13
Air flow Capacity : 34400 m3/hr (19952CFM)
Statics Pressure (S.P) : 979 PA
Entering Air Temparature : 28.5℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 953 LPM
AHU-14
Air flow Capacity : 31400 m3/hr (18021CFM)
Statics Pressure (S.P) : 979 PA
Entering Air Temparature : 28.2℃ DB & 20.9 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 845 LPM
AHU-15
Air flow Capacity : 5700 m3/hr (3306CFM)
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 28.5℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 13.5℃ DB &12.3℃ WB
Chilled water flow rate : 158 LPM
AHU-16
Air flow Capacity : 6100 m3/hr (3538CFM)
Statics Pressure (S.P) : 930 PA
Entering Air Temparature : 28.4℃ DB & 21.4 ℃ WB
Leavring Air Temparature : 14.9℃ DB &13.7℃ WB
Chilled water flow rate : 155 LPM
AHU-17
Air flow Capacity : 2900 m3/hr (1682 CFM)
Statics Pressure (S.P) : 880 PA
Entering Air Temparature : 28.0℃ DB & 21.1 ℃ WB
Leavring Air Temparature : 14.9℃ DB &13.4℃ WB
Chilled water flow rate : 72 LPM
AHU-18
Air flow Capacity : 11400 m3/hr (6612 CFM)
Statics Pressure (S.P) : 930 PA
Entering Air Temparature : 28.9℃ DB & 21.9 ℃ WB
Leavring Air Temparature : 14.9℃ DB &13.7℃ WB
Chilled water flow rate : 305 LPM
AHU-19
Air flow Capacity : 9000 m3/hr (5220CFM)
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 36.3℃ DB & 27.0 ℃ WB
Leavring Air Temparature : 19.8℃ DB &18.7℃ WB
Chilled water flow rate : 301 LPM
AHU-20
Air flow Capacity : 3500 m3/hr (2030CFM)
Statics Pressure (S.P) : 996 PA
Statics Pressure (S.P) : 996 PA
Entering Air Temparature : 36.3℃ DB & 27.0 ℃ WB
Leavring Air Temparature : 19.8℃ DB &18.7℃ WB
Chilled water flow rate : 117 LPM
CHILLED WATER FAN COIL UNIT (FCU)
Supply, installation, testing and commissioning of Ceiling Mounted concealed type Chilled Water Fan Coil Units
having cooling capacities as mentioned below. Each unit shall be complete with chilled water cooling coil,
centrifugal fan, fan motor, washable air filter, insulated return air chamber, insulated condensate tray etc. Each unit
also shall be complete with insulated enclosue, duct collar, hangers, vibration isolators, vent port built in inside the
unit. The fan shall have the capacity to handle required air against an external static pressure of the fan. The unit
shall have at lest 4 row coil depth and have the following capacities at chilled water entering the coil at 44.60F and
leaving the coil at 53.60F. FCU shall be controlled and monitor from BMS. Details as per Technical
Sepecification.

The unit shall operate when supplied with 200v~240v/50 hz/1ph power.
The Fan Coil Units shall have the capacity to cool air from 750F DB/650F WB and
leaving the coil at 550F DB / 540F WB.
FCU-01
Cooling Capacity : 5710 W / 1.5 TR
Air flow : 540 cfm
Chilled Water Flow Rate :3.6 US Gpm
External static pressure: 0.4 inch WG
FCU-02
Cooling Capacity : 4940 W / 1.6 TR
Air flow : 630
Chilled Water Flow Rate : 3.6 US Gpm
External static pressure: 0.4 inch WG
FCU-03
Cooling Capacity : 7,190 W / 2 TR
Air flow : 720 cfm
Chilled Water Flow Rate : 4.8 US Gpm
External static pressure: 0.4 inch WG
FCU-04
Cooling Capacity : 11,490 W / 3.25TR
Air flow:1080 cfm
Chilled Water Flow Rate :7.2 US Gpm
Variable Refrigerant Flow /Volume (VRF/VRV) System with Fan Coil Unit
VRF/VRV Condensing Units (Outdoor unit)

Variable Refrigerant Flow (VRF/VRV) units having following cooling capacities and other parameters as
mentioned below. Each unit shall have multiple Inverter type variable speed Compressors, DX Condenser with
Copper tube & Aluminum Fins.
Condenser Fan with Fan guard, Terminal board, over current protector, Voltage Transformer, Temperature sensor,
Pressure sensors, built in Oil separator & Accumulator etc, complete in all respect. The unit shall operate when
supplied with 400±10% V / 50hz
/ 3 Ph Electric power.

The supply includes all accessories to complete VRF mechanism including Voltage free
contact for connection with BMS.
Condenser air inlet temperature: 35 deg C
Refrigerant: R410A, Factory Charged
Compressor type: Inverter driven type
ESP of Outdoor unit Fan: 80 Pa
COP: 3.6 or higher
VRF Outdoor unit: Capacity : 62.0 kw
VRF/VRV Fan Coil Unit (Indoor Unit)
Evaporative units hoving cooling copacities as mentioned below. Each unit sholl complete with EXV, washable
filter , variable fan speed controller etc. Each unit shall
run with 50hz-1ph-220V power supply. Each unit shall have individual remote
Air entering to cooling coil: 27 0C DB / 19 0C WB
Type: Cassette Type ceiling hide away type
Wall mounted Networking Thermostat,
Refrigerant Branch Pipe Connector (RefNet or equivallent)
Ceiling Concealed Cassette Type Fan Coil Unit
4-Way Cassette Type
Cooling capacity : 8.3 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 10.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.8 kw
External static pressure : 0.40 inch WG
Cooling capacity : 9.9 kw
External static pressure : 0.40 inch WG
Cooling capacity : 11.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.5 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.7 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.4 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 7.5 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.9 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.3 kw
External static pressure : 0.40 inch WG
Cooling capacity :7.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :3.7 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 6.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :5.5 kw
External static pressure : 0.40 inch WG
Cooling capacity :4.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.4 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.1 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 12.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :6.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :3.2 kw
External static pressure : 0.40 inch WG
Cooling capacity : 5.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 2.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :7.0 kw
External static pressure : 0.40 inch WG
2-Way Cassette Type
Cooling capacity : 3.7 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.4 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.9 kw
External static pressure : 0.40 inch WG
Cooling capacity : 3.5 kw
External static pressure : 0.40 inch WG
Floor Stand Type Indoor unit
Cooling capacity : 7.6 kw
External static pressure : 0.40 inch WG
Cooling capacity : 4.1 kw
External static pressure : 0.40 inch WG
Cooling capacity : 10.1 kw
External static pressure : 0.40 inch WG
Cooling capacity : 8.0 kw
External static pressure : 0.40 inch WG
Cooling capacity : 11.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.0 kw
External static pressure : 0.40 inch WG
Cooling capacity :12.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.6 kw
External static pressure : 0.40 inch WG
Cooling capacity :8.2 kw
External static pressure : 0.40 inch WG
Cooling capacity :5.7 kw
External static pressure : 0.40 inch WG
Cooling capacity :10.9 kw
External static pressure : 0.40 inch WG
VENTILATION FAN :

Supply and installation of cabinet type supply air/exhaust air fan complete with fan, fan motor, fan section,
supports, starters, switches, casing, air filter, mounting accessories and all other components complete in all
respect. Details as per Technical Specification.

SF-1
Flow Capacity : 25,400 m3/hr
External static pressure : 250 PA
SF-2
Flow Capacity : 25,300 m3/hr
External static pressure : 250 PA
EF-3
Flow Capacity : 14700 m3/hr
External static pressure : 300 PA
EF-4
Flow Capacity : 12100 m3/hr
External static pressure : 300 PA
EF-5
Flow Capacity : 10900 m3/hr
External static pressure : 300 PA
SF-6
Flow Capacity :10500 m3/hr
External static pressure : 250 PA
EF-7
Flow Capacity : 10000 m3/hr
External static pressure : 250 PA
EF-8
Flow Capacity : 8100 m3/hr
External static pressure : 300 PA
SF-9
Flow Capacity : 5400 m3/hr
External static pressure : 250 PA
EF-10
Flow Capacity : 3800 m3/hr
External static pressure : 250 PA
EF-11
Flow Capacity : 2600 m3/hr
External static pressure : 300 PA
EF-12
Flow Capacity : 2200 m3/hr
External static pressure : 250 PA
EF-13
Flow Capacity : 2150 m3/hr
External static pressure : 250 PA
SF-14
Flow Capacity : 2100 m3/hr
External static pressure : 250 PA
EF-15
Flow Capacity : 1900 m3/hr
External static pressure : 250 PA
EF-16
Flow Capacity : 1700 m3/hr
External static pressure : 250 PA
EF-17
Flow Capacity : 1500 m3/hr
External static pressure : 250 PA
EF-18
Flow Capacity : 1290 m3/hr
External static pressure : 250 PA
EF-19
Flow Capacity : 480 m3/hr
External static pressure : 30 PA
EF-20
Flow Capacity :600 m3/hr
External static pressure : 30 PA
EF-21
Flow Capacity : 400 m3/hr
External static pressure : 250 PA
EF-22
Flow Capacity :340m3/hr
External static pressure : 30 PA
Heat Recovery Ventilation:
Supply, installation and commissioning of heat recovery ventilation unit completed with cabinet, fresh air and
exhasut air centrifugal type forward curved fans, cross- flow type
heat recovery module, filters etc. as per following capacity.
Air flow Capacity :2400 m3/h
External static pressure : 1 inch WG
Air flow Capacity :2800 m3/h
External static pressure : 1 inch WG
Air flow Capacity :3400 m3/h
External static pressure : 1 inch WG
Air flow Capacity :3200 m3/h
External static pressure : 1 inch WG
Air flow Capacity :800 m3/h
External static pressure : 1 inch WG
Air flow Capacity :2900 m3/h
Chilled Water Valves & Accessories :
Supply, installaion, testing and commissionign of steel /cast iron Water Valves of different sizes for use in chilled
water and condenser water lines. The valves shall be
flanged type from size 2 inch dia.
Valves shall be threaded type below 2 inch dia. Valves shall be complete will with all
standard fittings and accessories. Details as per Technical Specification.
Y STRAINER :
Supply, installation, testing and commissioning of Y-Strainer. Details as per Technical
Specification.
250 mm dia
150 mm dia
100 mm dia
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
FLEXIBLE PIPE CONNECTOR :
Supply, installation, testing and commissioning of Flexible Pipe Connector. Details as
per Technical Specification.
250 mm dia
100mm dia
80mm dia
65mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Globe Valve
250 mm dia
100 mm dia
Check Valve
250mm Dia
200mm dia
Butterfly Valve
250 mm dia
100mm dia
80mm dia
65mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Motorized Butterfly Valve
250mm dia
200mm dia
Gate Valve
250mm dia
200mm dia
150mm dia
100 mm dia
80 mm dia
Solenoid Valve
100mm dia
80mm dia
65mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Solenoid Valve
25 mm dia
20 mm dia
Ball Valve
50 mm dia
40 mm dia
32 mm dia
25 mm Dia
20 mm Dia
Automatic Air Vent
20 mm Dia
Drain Valve
80 mm Dia
65 mm Dia
50 mm Dia
40 mm Dia
Water Flow Balancing Valve :
Supply and installation of flow balancing valve complete with all accessories and components for balancing and
recording of rates of chilled water flow through pipes.
Details as per Technical Specification.
250 mm dia.
METERING DEVICES :
Supply, installation and testing of following Metering Devices. Details as per
Technical Specification.
Pressure Gauge (Size : 4" dia , Range 0 ~ 300 PSI)
Pipe thermometers (0 ~ 150o F)
Pipe thermosate (0 ~ 150o F)
WATER SOFTENER
Supply, installation, testing and commissioning of raw water softener as per detail
specification and instructions of Engineer-in-charge. Capacity : 240 Us Gpm
AIR SEPARATOR:
Supply and installation of Air Separator as per detail technical specification & as per
direction of Engineer- in-charge.
Capacity : 5000 Us gpm
Capacity : 7500 Us gpm
BUILDING MANAGEMENT SYSTEM (BMS) :

Supply and installation of Building Management and Control system suitable to control operation, monitoring
and management of the (HVAC) system, Electrical system, Fire Safty & Security system, Plumbing system, Lift
management system from a central location, log and retrieve data of the operation and failure status of the

The system shall be complete with sensors, transducers, transmitters, relays, direct digital controllers (DDC),
network units, computers, printers, cables, relevant hardware and software complete in all respect. BMS shall be
as per BACnet protocol. The supply power shall be 200v ~ 250v/1ph/50hz power. Details as per Technical

AIR TERMINALS :

Air terminals shall be constructed with extruded aluminum with powder coating finishing. Thickness shall
be not less than 18 SWG. Sizes mentioned are neck sizes.

SUPPLY & RETURN AIR TERMINALS :

Supply and installation of Ceiling Mounted Supply Air Diffuser made of extruded Aluminium having neck
size as per following. Details as per Technical Specification.

SYPPLY ROUND DIFFUSER:


Dia 300 mm
Dia 250 mm
RETURN SQUARE GRILL:
(450mm x 450mm )
(400mm x400mm)
(300mm x 300mm)
(500mm x 500mm)
(600mm x 600mm)
(800mm x 800mm)
(150mm x 150mm)
SUPPLY & RETURN AIR GRILLE :
Supply and installation of Ceiling Mounted/Wall Mounted Return/ Exhaust Air Grilles made of extruded
aluminium complete with neck damper having face size as per
following. Details as per Technical Specification.
(1200mmx150mm)
(1500mmX150mm)
(1800mmx 150mm)
(2400mm x 150mm)
(2100mm x 150mm)
(2700mm x 150mm)
(2800mm x 150mm)
(3000mm x 150mm)
(3000mm x 200mm)
(3600mm x150mm)
(900mm x 150mm)
(600mm x 150mm)
FRESH AIR/EXHAUST AIR LOUVER ;
Supply and installation of Wall Mounted Fresh Air/ Exhaust Air Louver made of
aluminum with powder coating. Size as per following. Details as per Technical
1400mm x 700mm)
(1000mm x500 mm)
(550 mm x 300 mm)
(800 mm x 450 mm)
(700 mm x350 mm)
(650 mm x350 mm)
(350 mm x 200 mm)
(950 mm x 500 mm)
(1100 mm x 550 mm)
(1050 mm x550 mm)
(600 mm x300 mm)
(400mm x200 mm)
(550mm x 250mm)
(450mm x 250mm)
(400mm x 200mm)
METAL DUCTING : (Machine Made)
Supply, installation and smoke testing of 120 gsm zinc coating, minimised spangle, JIS G3302 standards of
different sizes as per drawing and design including supply of all
materials and consumable. Details as per Technical Specification.
Ducts made of 20 SWG GP Sheets (1.0 mm)
Ducts made of 22 SWG GP Sheets (0.8 mm)
Ducts made of 24 SWG GP Sheets (0.6 mm)
DUCT INSULATION:

Supply and installation of 15 mm thick, 60 micron aluminium foil backed with self adhesive, class O nitrile rubber
insulation on outside surface of metal ducts including supply of all materials and consumable as per drawing and
detail technical specification. The density shall be 40 to 60 kg/m3 density.

DUCT LINING:
Supply and installation of Acoustic Duct Liner inside the duct according to drawing and
detail technical specification including supply of all materials and consumables.
15 mm thick open cell nitrile rubber acoustic lining with self adhesive having density 140
kg/m3
DUCT FLEXIBLE JOINT :
Duct connected with Fan Coil Units, Air Handling Units, Fans shall be done with Nylex or equivalent Flexible
connection. Width shall be 150 mm. Constructional details shall
have to be shown in Shop drawing.
FLEXIBLE ROUND DUCT :
Supply and installation of flexible round duct of density 16 kg/m3.
300mm
SPLITTER FIRE DAMPER :
Supply and installation of Splitter Fire Damper as per drawing including supply of all
materials and consumable. Details as per Technical Specification.
MANUAL VOLUME CONTROL DAMPER :
Supply and installation of Manual Volume Control Damper including supply of all
materials and consumable. Details as per Technical Specification.
250 mm dia
200 mm dia
275 mm dia
175 mm dia
150 mm dia
BLACK STEEL PRE-INSULATED PIPES :

Supply, installation, testing and commissioning of class C heavy black steel pipes with rigid polyurethane foam of
density 45 kg/m3 and galvanised steel spiral outside lockseamed of 0.5 to 0.6 mm thick for all the chilled water
piping system including cutting, edge preparation, welding etc. Pipe hanger/isolator boxes with spring isolators,
hanger rods, stell supports, anchors, all materials and consumable in this connection shall be supplied by the
contractor under this head. Details as per Technical Specification.

450 mm dia.
400 mm dia.
300 mm dia.
250 mm dia.
200 mm dia.
150 mm dia.
350 mm dia.
100 mm dia.
125 mm dia.
80 mm dia
65 mm dia
50 mm dia
40 mm dia
32 mm dia
25 mm dia
20 mm dia
12 mm dia
Refrigerant Pipe & Accessories
Refrigerant Piping shall be medium grade (L) Copper piping with long bend, support,
hangers, other accessories.
Pipe shall be c/w Nitrile rubber insulation of min 19mm thick.
Ø 6.4mm, thicknes: 0.8 mm
Ø 9.5mm, thicknes: 0.8 mm
Ø 12.7mm, thicknes: 1 mm
Ø 15.9mm, thicknes: 1 mm
Ø 19.1mm, thicknes: 1 mm
Ø 22.2mm, thicknes: 1.2 mm
Ø 28.5mm, thicknes: 1.3 mm
Ø 34.9mm, thicknes: 1.5 mm
R-410a Refrigerant Gas Charge as per Calculation and Manufacturer
Nitrogen Flash and pressure test as per manufacturer recommendation.
Tray for VRF Refrigerant Pipe :

Supply, Fitting, Fixing of Tray System with all necessary hanger, support
,accessories and fittings, Fixing for commissioning of the equipment including all related works as follows
technical specification, drawing and time to time site instruction from Consultant / Owner/Engineer.

uPVC PIPES :
Supply, installation and testing of water grade uPVC pipes of the following sizes including supply and
installation of uPVC sockets, elbows, tees, traps, hangers, unions,
other consumable, etc. complete in all respect.
50 mm dia.
40 mm dia
32 mm dia.
20mm dia.
25mm dia.
CONDENSATE DRAIN PIPE INSULATION :
Supply and installation of nitrile rubber tube insulation of thickness 13 mm on all
condensate drain pipe lines including supply of all materials and consumable. Details as per Technical
Specification.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
20 mm dia.
Refinet :
Refinet for indoor suction
Refinet for indoor dicharge
EXPANSION TANK :

Supply and installation of closed type cylindrical expansion tank made of high quality PVC/Plastic. Tank having
connection for expansion pipe, feed water line, overflow line, drain line, appropriately rated make-up water pump,
safety valves and other accessories complete in all respect. The tank shall be installed 5 ft. above the top level of
chilled water piping. The tank shall be insulated with 25 mm thick insulation.

Capacity : 1000 gallons


MAKE-UP WATER TANK WITH FLOAT VALVE:

Supply and installation of high quality PVC/Plastic make-up water Tank along with adequately rated make-up
water pump, for make-up of water for cooling towers. The tank shall have connection for, feed water line,
overflow line, drain line etc. complete in all respect.

Capacity : 1500 gallons


Tagging, Identification and Painting
Tagging, identification and painting of Chillers, Pumps, AHUs, Fans, Pipings,
Cablings, etc. as per recommendation of the Consultant.
Testing, Commissioning and Balancing ( Chiller & VRF)

After proper installation and the system shall be tested, commissioned and balanced as per direction and
recommendation. Pipe work shall be tested at a test pressure of 10 Kg/CM2 for 24 hours without any link. Leak
testing shall be done for ductwork. Running each equipment independently shall do individual testing. System
charging with refrigerant if required shall be done as per manufacturer recommendation. All controls shall be
balanced properly.

After proper testing, commissioning and balancing the system shall run for seven days upto the satisfaction of the
owner. The contractor shall provide an operation and
maintenance training to the maintenance group deputed by the owner.

MECHANICAL EQUIPMENTS
ELEVATOR & ESCALATOR

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following Passenger lift (motor room-less type) complete with car, control panel, traction
machine (permanent magnet synchronous motor type), gearless, oil free, steel suspension ropes, safety
devices, guide rails, push buttons, with other necessary accessories etc. complete including counter weight
as required, suitable for installation & use in tropicalised country like Bangladesh (considering
ambient temperature from 00C to 460C and relative humidity from 40% to 98%) & as per detailed specifications
and standards as mentioned below herewith :

Brand & country of origin :


Fujitec (Japan), Hitachi (Japan), Kone (Finland), Mitsubishi (Japan), Otis (USA / Japan / France), Schindler
(Switzerland), Thyssenkrupp (Germany) or equivalent product; provided the lift manufacturing company
shall be a multinational one and shall have lift manufacturing capability for speed 10 m / sec
(minimum), also shall have lift manufacturing experience in their own factory for a period of not less than 60
years and the proposed brand of lift shall be manufactured and tested in FINLAND / FRANCE / GERMANY /
JAPAN / SWITZERLAND / UK / USA, complying all other detailed specifications stated in the item and
complete with provision of luminaries, lift car wall, floor & door finishes (as per the detail drawings &
equipment schedule), inclusive of necessary materials and supply, delivery, installation of CCTV cameras
inside all lifts, inclusive testing, commissioning and interface with PTB CCTV
System, c/w, Cable & GI conduit, etc in order to meet the functional intent of the system.

i) 24 persons (2000kg / 2100kg) Lift (Speed = 2.0 m/s)


ii) 17 Persons (1350Kg / 1400Kg) Lift up to 9th floor for Control Tower Building
(Speed = 2.5 m/s - 3.0 m/s)

Supply, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of Escalator complete with cladding finishes (as per the detail drawings & equipment schedule)
including all necessary cablings, conduits, trunking, labelling, devices, equipment, structural requirement in
order to meet the functional intent of the system.

i) Escalator size 11.0 m ~ 12.0 m


ii) Escalator size 15.0 m ~ 16.0 m
PASSENGER BOARDING BRIDGE

Boarding Bridges complete; from approved manufacturer; factory fabricated, factory finished, preasembled
in units, assembled and erected in position; including all associated electrical, lighting and control
systems, all anchor bolts, base plates, supports, fittings, painting, fixings and sealants including foundation
and civil works. Extended Lenght should be calculated from the following limit to dock all type of aircraft.

PBB Models (Glass wall Tunnel Type)


In addition to the Passenger Boarding Bridge, the cost of the following sub-items shall
include all the associated works mentioned in this item
a) Double Docking System
i) 3 tunnels, max 32 m ~ 35 m
ii) 2 tunnels, max 28 m ~ 29 m
b) Single Docking System
i) 2 tunnels, max 28 m ~ 29 m
Sub Total
BAGGAGE HANDLING SYSTEM
Arrival Baggage System (In-Bound Baggage)

Supply, delivery, installation, testing and commissioning of arrival baggage claim


carousel (flat type) c/w controls, electrical, cabling, conduits & trunkings and likes for a complete installation

In addition to the arrival baggage claim carousel, the cost of the following sub-items shall
include all the associated works mentioned in this item
i) 76 Meters, Flat Reclaim Carousel.
ii) 66 Meters, Flat Reclaim Carousel.
Supply, delivery & installation of arrival baggage conveyors (Breakdown Conveyor) c/w controls, photocells,
electrical, cabling, conduits & trunkings and likes for a complete
installation
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Horizontal Conveyor (2 Segments)
ii) Incline/Decline Conveyor (2 Segments)
iii) Queuing Conveyor (Min: 1.2 M in Length)
Supply, delivery & installation of 90 deg power curve c/w controls, photocells, electrical,
cabling, conduits & trunkings and likes for a complete installation
In addition to the power curves, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) 90 Degree Power Curve (3.628 Mtr Each)
Supply, delivery & installation of heavy duty stainless steel roller beds and likes for a
complete installation
In addition to the roller beds, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Roller Beds (3 Nos. & 2 meter in length each)
Supply, delivery, installation, testing and commissioning of Arrival X-ray Machine (Inline) for Custom
Screening-Standard Size Baggage c/w UPS, associated conveyors,
S.S roller belts, operator workstation and other necessary accessories.

Supply, delivery, installation, testing and commissioning of fire/security doors and draft curtains c/w controls,
photocells, electrical, cabling, conduits & trunkings, interfacing and coordination with various trades as
specified, audible and visual warning signages, certification and likes for a complete installation

Supply, delivery, installation, testing and commissioning of emergency stop buttons c/w controls, electrical,
cabling, conduits & trunkings, interfacing and coordination with various trades as specified, audible and
visual warning signages and likes for a complete installation

Supply and installation of the electrical control panels housing the motor controls, starters, control relays,
cabling works, cable supports and motor protection relays to control and interlock the various components
of the system for proper starting and stopping of the system.

Departure Baggage System (Out-Bound Baggage)

Supply, delivery & installation of Passengers Check-in Counter / Desk made of GRP with operators &
passengers display of weighing scale system and accessories, c/w controls, key switch, electrical, cabling,
conduits & trunkings, emergency stop and likes for a complete installation.
In addition to the Check in Counter / Desk, the cost of the following sub-items shall
include all the associated works mentioned in this item
i) Check-in Counter / Desk (36 Nos. included in item No. 5.3.4.22)
Supply, delivery & installation of 1.2m long and 600mm wide Scale Conveyors with load
cells and accessories, c/w controls, photocells, electrical, cabling, conduits & trunkings and likes for a complete
installation.
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Check-in Scale Conveyor

Supply, delivery & installation of 1.2m long and 600mm wide Induction Conveyors and
accessories, c/w controls, photocells, electrical, cabling, conduits & trunkings and likes for a complete installation

In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Check-in Induction Conveyor
Supply, delivery & installation of outbound take-away/collection conveyors at the check- in island c/w controls,
photocells, electrical, cabling, conduits & trunkings and likes for a
complete installation
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Take-away/collection Conveyor-1 (1/2 Segments)
ii) Take-away/collection Conveyor-2 (1/2 Segments)
iii) Take-away/collection Conveyor-3(1/2 Segments)

Supply, delivery & installation of departure baggage conveyors c/w controls, photocells, electrical, cabling,
conduits & trunkings and likes for a complete installation

In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Horizontal Conveyor (Min 12 segments)
ii) Queuing Conveyor (Min: 1.2 M in Length)
iii) Horizontal Conveyor (Min 4 segments) for OOG conveyor.
iv) Queuing Conveyor (Min: 1.2 M in Length) for OOG conveyor.
Supply, delivery & installation of Auto Wheel Diverters, c/w controls, photocells,
electrical, cabling, conduits & trunkings and likes for a complete installation
In addition to the auto wheel divertors, the cost of the following sub-items shall include
all the associated works mentioned in this item
i) Auto Wheel Diverters (Left and Right operation)
Supply, delivery & installation of departure baggage conveyors 2 & 3 interconnected conveyor c/w
controls, photocells, electrical, cabling, conduits & trunkings and likes for
a complete installation
In addition to the conveyors, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Horizontal Conveyor (Bidirectional Belt conveyor)
Supply, delivery & installation of 90 deg power curve c/w controls, photocells, electrical,
cabling, conduits & trunkings and likes for a complete installation
In addition to the power curves, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) 90 Degree Power Curve
Supply, delivery & installation of heavy duty stainless steel roller beds and likes for a
complete installation
In addition to the roller beds, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) Roller Beds (3 Nos. 3 meter in length each and 3 Nos. 1 meter in length each and 4
Nos. 3 meter in length each for Cargo Scanning)

Supply, delivery, installation, testing and commissioning of fire/security doors/roller shutter and draft
curtains c/w controls, electrical, cabling, conduits & trunkings, interfacing and coordination with various
trades as specified,audible and visual warning signages, certification and likes for a complete installation

Supply, delivery & installation of 360 deg scanner (Automatic Tag Reader, ATR) c/w connection belts,
controls, photocells, electrical, cabling, conduits & trunkings and likes
for a complete installation
In addition to the 360 deg scanner, the cost of the following sub-items shall include all
the associated works mentioned in this item
i) 360 Degree Scanners

Supply, delivery, installation, testing and commissioning of ICAO & IATA Compliant ECAC-STD-3 In-line
Screening Machine with UPS, accessories and tracking system suitable for Level 1 and Level 2 security
screening of hold baggage (1800 Bags/Hr)

In addition to the scanners, the cost of the above item shall include 6 Staff Operated On- screen Resolution
(OSR) Work Stations for Level-1 rejected images complete with servers, controls, electrical power and
data cables., etc and all associated works mentioned in this item

i) L1-01
ii) L1-02
iii) L1-03 ( For Cargo Scanning)

Supply, delivery, installation, testing and commissioning of ICAO & IATA Compliant ECAC-STD-3 In-line
Screening Machine with UPS, accessories and tracking system suitable for Level 1 and Level 2 security
screening of hold baggage (1800 Bags/Hr)

In addition to the scanners, the cost of the above item shall include 6 Staff Operated On- screen Resolution
(OSR) Work Stations for Level-1 rejected images complete with servers, controls, electrical power and
data cables., etc and all associated works mentioned in this item and as per design, drawing, relavant
specification and accepted by the Engineer.

i) Dual view X-Ray Scanning Machine with UPS, STP and with necessory accessories
(Hold baggage screening)

Level-3 Staff Operated On-screen Resolution (OSR) Work Stations for the rejected images from Level-2 in
parallel to ETD System as redundancy provision complete with servers, controls, electrical power and data
cables., etc and all associated works mentioned in this item.

Supply, delivery, installation, testing and commissioning of ICAO & IATA Compliant Screening Machine for
Over-size Outbound Baggage (1000x1000 MM Tunnel Size Stand alone machine c/w UPS, associated
conveyors, S.S roller belts, operator work stations and other necessary accessories)

In addition to the scanners, the cost of the above item shall include 02 operator
workstations, servers, controls etc and all associated works mentioned in this item
Supply, delivery, installation, testing and commissioning of Explosive Trace Detection Device (ETD) with
accessories and tracking system suitable for Level 3 & 4 screening of
hold baggage
Supply, delivery, installation, testing and commissioning of Manual Encoding Equipment
with accessories and tracking system
In addition to MES, the cost of the above item shall include individual operator workstations, servers,
controls, hand held scanners, consoles, furnitures, lightings, power
point, tag printers etc and all associated works mentioned in this item

Supply, delivery, installation, testing and commissioning of emergency stop buttons c/w controls, electrical,
cabling, conduits & trunkings, interfacing and coordination with various trades as specified, audible and
visual warning signages and likes for a complete installation

Supply and installation of the electrical control panels housing the motor controls, starters, control relays,
cabling works, cable supports and motor protection relays to control and interlock the various components
of the system for proper starting and stopping of the system.

BHS Control System and Interfacing Work

Design, supply, installation, testing and commissioning of baggage control systems, Baggage Handling
System’s Virtual Local Area Network (VLAN-BHS), and equipments within and outside of the Baggage control
room., etc as listed below, but not limited to, comply with technical specification including all necessary
drawings, diagrams and supporting documents.

BHS central control system and consoles


BHS servers/racks/host/computers/gateways/ network/switches/modems
Telecommunication cablling and cable supports
PLC controllers, relays, auxillary accessories
Software Programming
Application softwares and associated licenses
User's workstations, laptops and printers
Maintenance Management Information System
Maintenance Diagnostic System
UPS (1 Hour Battery Backup)
Ground Handler Query Workstation
Equipment in Baggage Control Room
Workstations Outside the Baggage Control Room
Reporting Server Sub-system
Security and custom management computer system
Supply, installation, testing and commissioning of interfacing gateways, workstations, Hardware c/w
coordination, cabling, connections, consoles and Software programming
for the interfacing works with other airport systems.
Management Computer Sub-system
Interface to Airport Flight Information Display System
Interface to Airline Departure Control System
Interface to Airport Operations Database System
Interface to Baggage Information Display System
Interface to Common User Baggage Enterprise System
Interface to Ground Handler Query Workstation
Interface to Reporting Server Sub-system
Interface to Security and custom management computer system
Testing and Commissioning

Cost of testing and commissioning (which shall include all Airport Operation Readiness Trials) of the complete
Baggage Handling System installation including a minimum quantity of 3600 dummy baggages, all
necessary materials, equipment and labour, as required.

Miscellaneous

Design, fabrication, assembly, transportation, delivery, installation, and/or erection of the structural steel works
for the following Baggage Handling System (BHS) screening platforms and, manual encoding stations, as
per standard including all related items, appurtenances and shop coats or protective paint, complete in
every respect in strict accordance with standard Specification applicable drawings, and subject to the terms and
conditions of the Contract.

1 nos. of Manual Encoding Station Platform (including fire resistance of at least 2 hours)

4 nos. of Screening Machine Platforms

The Contractor shall supply and install maintenance power points along the length of the conveyor belt. The
work shall include but not limited to the provision of distribution boards, galvanized steel conduits,
earthings and proper mounting brackets.

To provide painting, labelling, tagging of BHS equipment as specified and likes for a
complete BHS installation
To provide audible and visual safety, warning and directional signages etc c/w controls, electrical, cabling,
conduits & trunkings, interfacing with various trades as specified and
likes for a complete BHS installation
To provide acoustic treatment to the BHS, including measurements and evaluation by
qualified person, to comply with the noise levels as specified.
To provide maintenance hoisting hook permanently beside all Security Screening Machines as specified all
& 2 sets of chain block and 2 sets of electrical and mechanical
tool for BHS for maintenance and repair.
To provide Threat Containment Vessel (TCV) c/w necessary accessories and conveyors
for connection to the BHS System as specified

GATE MANAGEMENT SYSTEM, FLIGHT CONTROL & AODB


Supply, installation, testing and commission with airport readiness trial of the following
equipment :
GMS and Flight Control Server with Redundancy
Supply, delivery and installation (which shall include all Airport Operation Readiness Trials) of the
following servers complete with necessary patching cards, racks and
standby UPS.

1 x database server in cluster configuration


(load balancing) – Xeon Quad Core processor @ 3 GHz - 4 GB RAM min. - 2 x Gigabit Ethernet adapter-
Redundant power supply – 2 x 500 GB hard disk - MS XP Professional operating system

1 x application server - Xeon Quad Core processor @ 3 GHz - 4 GB RAM min. - Gigabit Ethernet adapter - 2 x
500 GB hard disk - MS XP Professional operating system

Service console with 19" LCD monitor,


keyboard, mouse and KVM switch
3KVA 230V 50Hz Rack Mounted UPS for 2 hrs (min)
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
Workstations (apron control room-1nos, BHS control room -1no, AOC-1no, finance-1no,
comms equipment rooms -1no)

Supply, delivery and installation (which shall include all Airport Operation Readiness Trials) of the following
IBM PC compatible workstation complete with necessary patching cards, racks and standby UPS.

Workstation with Quad Core processor @ 2.4 GHz – 4 GB RAM – 500 GB hard disk –
Gigabit Ethernet adapter
21” LCD monitor
B/W laser printer
GMS Client license
1KVA 230V 50Hz UPS for 2 hrs (min)
Gate Management System (GMS) Software
Database software license
Application license
Customization of the GMS package
Finance module for billing

Interface and Link to the following systems:


- Airport Operation Database (AODB),
- Flight Control System (FCS),
- Building Management System (BMS)
- Common User Terminal Equipment (CUTE),
- Baggage Control System
- Flight Information Display System (FIDS)
- Airline Host Servers
- Master Clock

Application and Database software for Flight Control System (FCS)


Application and Database software for Airport Operation Database (AODB)

Supply, delivery and installation (which shall include all Airport Operation Readiness Trials) of the irport
Operation Database (AODB) enterprise servers (duty and hot standby) and software with programming
complete with necessary patching cards, racks and standby UPS.

Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) of high availability, load sharing layer 3 Core switches (equivalent to Cisco 6500E in duty and
hot standby), include ASA Firewall engine module, Network Mgt System complete with necessary
patching cords, cabling, accessories, RPS, racks and standby UPS.

Supply, delivery, installation, testing, commissioning (which shall include all Airport
Operation Readiness Trials) of signal converter, complete with necessary patching cords, cables and
accessories.
Supply, delivery, installation, testing, commissioning (which shall include all Airport
Operation Readiness Trials) of 4 core single mode fibre optic cables, complete with necessary cable
support, accessories and fiber patch panel.
CAT6 UTP distribution cables complete with cable support
Supply, delivery, installation, testing and commissioning (which shall include all Airport
Operation Readiness Trials) of 48 port fibre patch panels, complete with all necessary interconnection and
accessories in comms room
Supply, delivery, installation, testing and commissioning (which shall include all Airport
Operation Readiness Trials) of 4 port fibre patch panels, complete with all necessary interconnection and
accessories in comms room
Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Primary and Secondary
8 port RJ45 UTP Patch Panels including all necessary accessories
Hardware testing & commissioning including all airport operational trials
Hardware commissioning of all peripherals
GMS, FCS & AODB software commissioning including all airport operational trials
Software and Hardware Interconnects including cable support between servers,
distribution switches in Communication Equipment Room
Interconnects between workstations, signal converters and other peripherals
Interface with Airport Operation data base complete with cables, necessary hardware and
software data base.
Interface with Baggage Handling System complete with cables, necessary hardware and
software data base.
Interface with Flight Control Server System complete with cables, necessary hardware
and software data base.
Interface with Flight Information Display Server complete with cables, necessary
hardware and software data base.
Interface with Common User Terminal Equipment complete with cables, necessary
hardware and software data base.
Interface with Master Clock System complete with cables, necessary hardware and
software data base.

Power point SSO including 2x 4mm2 1C PVC/PVC + 1C 4mm2 PVC E with cable
support tapping from nearest UDB located in Load Center (each cable length less than 80m)

MAST LIGHTING SYSTEM

Supply, delivery, installation, testing and commissioning of the following type of Luminaires, including all
cabling works, termination, concealed GI conduit, junction box complete with quick male & female connector,
supporting brackets and necessary accessories and link to respective lighting switches on External including
Control Panel Board, Base Foundation etc for each mast pole and 01 no power tool against 02 nos mast pole etc.
all complete as per direction of the engineer.

Fixtures: LED Lamp not less than 300W x 10


Mast pole H=25M,(Up Down system)
Supply and installation of LT Cable for Mast pole:
a) 1C-4x16 mm2 NYY/2XY cable with BYA ECC wire through PVC pipe
CABLE SUPPORTTING SYSTEM
Supply, delivery, installation, testing and commissioning of the following cable tray and
trunking including all necessary suspension fixtures and accessories on Level 1
E1
i) POWER : 1x450x100mm Tray
ii) LIGHTING : 1x300mmx100 Trunking
iii) POWER : 1x300mmx100 Trunking
iv) CCTV : 1x300mmx100 Trunking
v) COMM : 3x300mmx100 Trunking
vi) FAS : 1x150mmx100 Trunking
vii) PA : 1x300mmx100 Trunking
E2
i) LIGHTING : 1x150mmx100 Trunking
ii) POWER : 1x150mmx100 Trunking
iii) CCTV : 1x150mmx100 Trunking
iv) COMM :1x150mmx100 Trunking
v) FAS : 1x150mmx100 Trunking
vi) PA : 1x300mmx100 Trunking
E6
i) ELECT : 6x700mm LADDERS
E7
i) ELECT : 2x600mm Tray
E8
i) ELECT : 2x300mm Tray
Supply, delivery, installation, testing and commissioning of the following cable tray and
trunking including all necessary accessories on Roof
G
i) ELECT : 1x300mmx100mm Trunking
Supply, delivery, installation, testing and commissioning of the following concrete
haunched UPVC pipe including all necessary accessories on the External
i) 1x110mm Dia concrete UPVC pipe
ii) 2x150mm Dia concrete UPVC pipe
iii) 4x150mm Dia concrete UPVC pipe
Underfloor Trunking
Supply, delivery, installation, testing and commissioning of the Underfloor Trunking
including wiring, fixing bracket, spike and necessary accessories on Level 1
Pre-galvanised 300mm 3-Compartment Flush Floor Trunking

300mm Junction Box c/w cover, 1 no Twin 13A powerpoints, 2 nos of RJ45 and/or RJ11

300mm Junction Box c/w cover, 1 no Twin 13A powerpoints


300mm Junction Box c/w cover

300mm Junction Box c/w cover, 25mm diameter G.I conduits linking from floor trunking junction box to ceiling
space for fire alarm detector/ bell/ FIDS/ CCTV/ speakers.

Concealed GI conduit pipe in column for speakers, linear beam detector, CCTV, FIDS,
clock, TV point
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

M 60,750.00
M 1,870.00
M 5,201.00
M 2,640.00
M 2,655.00
M 4,280.00
M 2,335.00
M 2,160.00
M 2,890.00
M 840.00
M 840.00

Nos. 3,045.00
Nos. 5,550.00
Nos. 1,470.00
Nos. 1,910.00

Nos. 44.00
Nos. 19.00

Nos. 2.00

Nos. 106.00
Nos. 106.00
Nos. 14.00
Nos. 7.00

M 330.00

Nos. 9.00
Nos. 7.00

Nos. 45.00

Job 4.00

Nos. 1.00

Nos. 1.00

Nos. 1.00
Lot 1.00

No 12.00

No 186.00

No 82.00

No 72.00

No 70.00

No 62.00

No 222.00

No 10.00
No 279.00

No 260.00

Sqm 238.00

No 175.00

No 175.00

No 246.00

No 255.00
No 40.00

No 750.00

No 433.00
No 22.00
No 49.00

No 433.00
No 58.00
Rft 2,500.00
Rft 340.00
Rft 2,450.00
Rft 5,805.00
Rft 740.00
Rft 11,000.00
Rft 4,620.00
Rft 1,210.00
Rft 120.00

Rft 11,900.00
Rft 4,250.00
Rft 460.00
Rft 280.00
Rft 390.00
Rft 610.00
Rft 515.00
Rft 175.00

No 117.00
No 39.00
No 31.00
No 34.00
No 36.00
No 18.00
No 10.00
No 10.00
No 34.00
No 53.00
No 45.00
No 23.00

No 9.00

No 16.00

No 430.00
No 22.00

No 11.00

No 22.00

No 20.00

No 20.00
No 20.00

No 20.00

No 20.00

No 300
No 240
No 150
No 720
No 40
No 430
No 360
No 325

No 4080

No 70

No 1030
No 1032
No 310
No 310
No 80
No 90
No 2852
No 35

No 35

No 270
No 120
No 60
No 160
No 92
No 120
No 60
no 40
No 60
No 30

No 125
No 90
No 50

No 530
No 515
No 517

No 727
No 425
No 450
No 165

No 165

No 260
No 220

No 655
No 340
No 340
No 40

No 25
No 125
No 250

No 50

No 266

No 6124

No 1775

No 1063

No 1244

No 12
No 71
No 431

No 337

No 11057

NOS 2

NOS 2

M 7200

NOS 2

NOS 7
NOS 5

NOS 3

NOS 2

NOS 1
NOS 1

NOS 1

NOS 1

2
set 2

m 1600

Job 3

No 3

No 2
set 1

set 4
set 2

set 2

no 1
no 2

no 1

no 1

no 5
E

no 10

E
no 4

no 4
E

no 26

E
no 135

no 30
no 50
no 10
no 45
no 30
no 25

m 150
m 100
m 115
m 150
m 1050
m 2020
m 500
m 5000
m 4260
m 305
m 4,000
m 2900
m 3250
m 1,760

m 2,000
m 1,600
m 1,200
m 1,000
m 1,900
m 2,000
m 1,800
m 600

No 2

No 2

No 3
No 6
m 4,030
No 16

No 1

No 16

No 622

No 3622

No 189
No 158

No 675

No 206

No 145

No 298

M 124500
M 77800

Lot 1
Set 2

Set 2
Set 2

Set 2

Set 2

Set 2

Lot 1

Lot 1

Job 1

Job 1

Set 1
Set 1

Set 1

Set 1

Set 1

Set 2

Set 1

Set 1

Set 1

No. 1

Each 2
No 1

Job 1

Set 2
Set 2

Set 2

Set 2

Set 2

Set 2
Nos. 1

Nos. 2

Nos. 2

Nos. 2

Set 2
Job 1

Job 1

LS
Set 4

Sets 4
Sets 4

Set 5
Set 5

Set 1

Nos. 1

Nos 1

1
1

1
1

1
Nos. 8

Nos. 25

Nos. 52

Nos. 20

Nos 13
Nos 2

Nos 2

Nos 2

Nos 4

Nos 2

Nos 5

Nos 2

Nos 1

Nos 1

Nos 2

Nos 2

Nos 1

Nos 5

Nos 1

Nos 1

Nos 2

Nos 1

Nos 2

Nos 3
Nos 1

Nos 2

Nos 2

Nos 3

Nos 2

Nos 3

Nos 2

Nos 1

Nos 1

Nos 1

Nos 1

Nos 2

Nos 1

Nos 3

Nos 5

Nos 2

Nos 1

Nos 2

Nos 1

Nos 1

Nos 1

Nos 4

Nos 4
Nos 2

Nos 4

Nos 1

Nos 1

Nos 2

Nos. 1

Nos. 2

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1

Nos. 1
Nos. 1

Nos. 2

Nos. 1

Nos. 1

Nos. 2

Nos. 2

Nos. 2

Nos. 6

Nos 1

Nos. 2

Nos 1

Nos 2

Nos 1

Nos 2

Nos 5

Nos 1

Nos 3
Nos. 18
Nos. 1
Nos. 5
Nos. 15
Nos. 5
Nos. 5
Nos. 10
Nos. 5
Nos. 25
Nos. 90

Nos. 10
Nos. 16
Nos. 16
Nos. 4
Nos. 4
Nos. 4
Nos. 2
Nos. 2

Nos. 10
Nos. 4

Nos. 10
Nos. 10

Nos. 10
Nos. 16
Nos. 16
Nos. 4
Nos. 4
Nos. 4
Nos. 2
Nos. 2

Nos. 6
Nos. 2
Nos. 4
Nos. 16
Nos. 20
Nos. 6
Nos. 36

Nos. 16
Nos. 16
Nos. 4
Nos. 4
Nos. 4
Nos. 2
Nos. 2

Nos. 20
Nos. 85

Nos. 40
Nos. 2
Nos. 2
Nos. 3
Nos. 3

Nos. 50

Nos. 4
Nos. 24
Nos. 4
Nos. 3

Nos. 4

Nos. 40
Nos. 16
Nos. 4
Set 1

Set 1

Each 1
Each 1
Set 1

Nos. 1330
Nos. 405

Nos. 310
Nos. 100
Nos. 45
Nos. 75
Nos. 15
Nos. 65
Nos. 155

Nos. 46
Nos. 30
Nos. 34
Nos. 20
Nos. 30
Nos. 22
Nos. 2
Nos. 4
Nos. 56
Nos. 4
Nos. 40
Nos. 40
Nos. 5
Nos. 1
Nos. 2
Nos. 1
Nos. 1
Nos. 11
Nos. 5
Nos. 1
Nos. 1
Nos. 3
2
1
Nos. 5
Nos. 1
Nos. 4

Sq. ft. 100390


Sq. ft. 100390
Sq. ft. 139520
Sq. ft. 391340

Sq. ft. 120000

Nos. 365

Rft 350
Nos. 285

Nos. 140
Nos. 120
Nos. 85
Nos. 70
Nos. 50

Meter 480
Meter 2,800
Meter 50
Meter 600
Meter 3,900
Meter 200
Meter 40
Meter 220
Meter 300
Meter 40
Meter 110
Meter 190
Meter 120
Meter 265
Meter 320
Meter 450
Meter 40

Meter 1670
Meter 1270
Meter 1225
Meter 1025
Meter 625
Meter 650
Meter 1655
Meter 1025
Kg. 180
Lot 1
Lot 1
meter 70
meter 1,180
meter 260
meter 550
meter 1,752

meter 70
meter 1,180
meter 260
meter 550
meter 1,752

Nos 97
Nos 97

Nos. 1

Nos. 1
Job 1

Job 1
Nos. 8

Nos. 1

Nos. 3
Nos. 3

No 2
No 2

No 2
Set 2
Set 1

M 54
M 24
M 7.2

No 6

M 6

No 3

Set 6

lot 1

lot 1
Set 36

Set 36

M 24
M 18
M 24

M 90
M 13.2
M 20
M 2.4

No 5

M 1

No 6
M 24

Set 6

Set 3

No 1
No 1
No 1

No 1

Set 3

No 1
Set 3

Set 1

Lot 1

Lot 1

Lot 1

Lot 1
Lot 1

Lot 1

No 30

Lot 1
lot 1

lot 5

lot 1

lot 1
lot 1

lot 1

no 1

no 2

lot 1

lot 1

no 1
no 10

no 1

lot 1
lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

lot 1

No 20

M 2000

M 100
M 100
M 50
M 60
M 100
M 50
M 50

M 100
M 100
M 50
M 100
M 50
M 60

M 20

M 100

M 100

M 100

M 100
M 100
M 150

M 200

Nos 20

Nos 32
Nos 75

Nos 65

Nos 100
Item No.

5
5.1

5.1.1

5.1.2
5.1.3

5.1.4

5.1.5

5.1.6
5.1.7

5.1.8

5.1.9

5.1.10
5.1.11

5.1.12

5.1.13

5.1.14

5.1.15

5.1.16

5.1.17

5.1.18
5.1.18

5.1.19

5.1.20

5.1.21

5.1.22

5.1.23

5.1.24

5.1.25

5.1.26

5.1.27
5.1.27

5.1.28

5.1.29

5.1.30

5.1.31

5.1.32

5.1.33
5.1.34

5.1.35

5.1.36
5.1.37
5.1.38
5.1.39
5.1.40
5.1.41
5.1.42
5.1.43
5.1.44
5.1.45
5.1.46
5.1.47
5.1.48
5.1.49
5.1.50
5.1.51
5.1.52

5.1.53

5.1.54
5.1.55

5.3.4

5.3.4.1
5.3.4.2

5.3.4.3

5.3.4.4

5.3.4.5

5.3.4.6

5.3.4.7
5.3.4.8

5.3.4.9
5.3.4.10
5.3.4.11

5.3.4.12

5.3.4.13

5.3.4.14

5.3.4.15

5.3.4.16

5.3.4.17

5.3.4.18
5.3.4.19
5.3.4.20

5.3.4.21

5.3.4.22
5.3.4.23
5.3.4.24
5.3.4.25
5.3.4.26
5.3.4.27
5.3.4.28

5.3.4.29

5.3.4.30
5.3.4.31
5.3.4.32
5.3.4.33
5.3.4.34
5.3.4.35
5.3.4.36
5.3.4.37

5.3.4.38

5.3.4.39

5.3.4.40
5.3.4.41
5.3.4.42

5.3.4.43

5.3.4.44
5.3.4.45
5.3.4.46
5.3.4.47
5.3.4.48
5.3.4.49
5.3.4.50

5.3.4.51

5.3.8

5.3.8.1
5.3.8.2
5.3.8.3
5.3.8.4

5.3.8.5

5.3.8.6
5.3.8.7
5.3.8.8

5.3.8.9

5.3.9

5.3.9.1

6
o Navigational Aid System
onnection with Existing ILS/DME

6.1.1.1
6.1.1.2

6.1.1.3
6.1.1.4
6.1.1.5

6.1.1.6

Part 6.1: Radio Navigational Aid System


6.1.2 DVOR
6.1.2.1
6.1.2.2
6.1.2.3
6.1.2.4
6.1.2.5
6.1.2.6
6.1.2.7

6.1.2.8

6.1.2.9
6.1.2.10

o Navigational Aid System


6.1.3 Facilities for ATS Communication

6.1.3.1

6.1.3.2

6.1.3.3

6.1.3.4
6.1.3.5
6.1.3.6
6.1.3.7
6.1.3.8

6.1.3.9

6.1.3.10
6.1.3.11

6.1.3.12

6.1.3.13

6.1.3.14

6.1.3.15

6.1.3.16
6.1.3.17
6.1.3.18

6.1.3.19

6.1.3.20

6.1.3.21
6.1.3.22
6.1.3.23
6.1.3.22
6.1.3.23
6.1.3.24

6.1.3.25

6.1.3.26

6.1.3.27
6.1.3.28

g Communication Equipments
6.2.1

6.2.1.1
6.2.1.2

6.2.1.3

6.2.1.4

6.2.1.5

6.2.1.6

6.2.1.7

6.2.1.8

6.2.1.9
6.2.1.10

6.2.1.11

6.2.1.12

6.2.1.13
6.2.1.14
6.2.2

6.2.2.1

6.2.2.2

6.2.2.3

6.2.2.4

6.2.2.5

6.2.2.6
6.2.2.7
6.2.2.8
6.2.2.9

6.2.2.10

6.2.2.11

6.2.2.12

6.2.2.13

6.2.2.14

6.2.2.15

6.2.2.16

6.2.3

6.2.3.1
6.2.3.2
6.2.3.3
6.2.3.4
6.2.3.5

6.2.3.6
6.2.3.7
6.2.3.8
6.2.3.9

6.2.3.10
6.2.3.11
6.2.3.12

6.2.3.13
6.2.3.14

6.2.3.15
6.2.3.16

6.2.3.17
6.2.3.18
6.2.3.19
6.2.3.20
6.2.3.21
6.2.3.22
6.2.3.23
6.2.3.24
6.2.3.25
6.2.3.26
6.2.3.27
6.2.3.28
6.2.3.29

6.2.4

6.2.4.1
6.2.4.2
6.2.4.3

6.2.4.4

6.2.4.5
6.2.4.6
6.2.4.7
6.2.4.8
6.2.4.9
6.2.4.10
6.2.4.11
6.2.4.12

6.2.4.13

6.2.4.14

6.2.4.15

6.2.4.16

6.2.4.17

6.2.4.18
6.2.4.19
6.2.4.20
6.2.4.21

6.2.4.23
6.2.4.24
6.2.4.25
6.2.4.26
6.2.4.27
6.2.4.28
6.2.4.29

6.2.4.30

6.2.4.31

6.2.4.32

6.2.4.33

6.2.4.34

6.2.4.35
6.2.4.36
6.2.4.37
6.2.4.38

6.2.5

6.2.5.1
6.2.5.2
6.2.5.3

6.2.5.4
6.2.5.5
6.2.5.6
6.2.5.7
6.2.5.8

6.2.6

6.2.6.1

6.2.6.2

6.2.6.3

6.2.6.4

6.2.6.5

6.2.6.6

6.2.6.7

6.2.6.8

6.2.6.9

6.2.6.10

6.2.6.11

6.2.6.12

Part 6.3: Security Equipments


6.3.1

6.3.1.1

6.3.1.2
6.3.1.3
6.3.1.4
6.3.2

6.3.2.1
6.3.2.2

6.3.3

6.3.3.1
6.3.3.2
6.3.3.3
6.3.3.4

6.3.3.5

6.3.3.6
6.3.3.7
6.3.3.8
Description of Item

Electro-Mechanical Works
Airfield Ground Lighting ( AGL ) System

Supply, delivery, installation, testing and commissioning of the following LED lamp ( Minimum 30,000h
long life) with light fittings, c/w Frangible coupling : 2inch gas, Coten steel plate, Base mounting
plate : 2inch gas, electrical, Isolation transfomer, connector kit, etc i/c foundation works and likes for a
complete installation and as per ICAO Annex14, Vol 1, work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.

In addition to the LED lamp light fitting, the cost of the following sub-items shall include
all the associated works mentioned in this item
i) RWY Hligh Intensity Inset type Lights, 20W/2, 6.6A, pref. LED lamp, beams- white ,
white/yellow and 60W Isolation transfomer.
ii) TWY edge light elevated, 5W, 6.6A, pref. LED lamp, beams- blue and 15W Isolation
transfomer.
iii) TWY edge light Inset type Lights, 5W, 6.6A, pref. LED lamp, beams- blue and
15W Isolation transfomer.
iii) Inmtermidiate Holding Position Light (IHPL) Inset type Lights, 15W, 6.6A, pref.
LED lamp, beams- yellow and 30W Isolation transfomer.

Supply, delivery, installation, testing and commissioning of the following Airfield Signs having rotection level
IP45, Coat paint, Height of legend is 800mm, Polycarbonated front panel c/w aluminium housing, breakable
couplings, 150W+15W cold mirror LED lamps 30,000 h, serie power supply from 2.8 to 6.6 A works and likes
for a complete installation and as per Legend impormation - Annex 14, Vol.1, work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

a) Sine size 32EA


i) 800mm x1,200mm, TR 200W
ii) 800mm x1,400mm, TR 200W
iii) 800mm x1,600mm, TR 200W
iv) 800mm x1,800mm, TR 200W
v) 800mm x2,000mm, TR 200W
vi) 800mm x2,200mm, TR 200W
vii) 800mm x2,400mm, TR 200W
viii) 800mm x2,600mm, TR 200W
ix) 800mm x2,800mm, TR 200W
x) Breakable Coupling 50mm
b) Foundation Work
i) Foundation W= 1,600mm
ii) Foundation W= 2,200mm
iii) Foundation W= 2,600mm
iv) Foundation W= 2,800mm
v) Foundation W= 3,000mm
vi) Foundation W= 3,200mm
vii) Foundation W= 3,800mm
viii) Foundation W= 4,000mm
ix) Foundation W= 4,400mm
x) Foundation W= 4,600mm
xi) Foundation W= 5,400mm
ACMS

Design, supply, installation, testing and commissioning of Airfield light Control & Monitoring System c/w
Equipment, Cable, Computer, Panel, ect, Control Cable for ACMS loof networks, F.O(Fibre optical)
Single mode 8C, O.F FDF, UPS/ 1Phase 230V, ALL IGBT, 20kVA, Backup 30min and as listed below,
but not limited to, comply with technical specification including all necessary drawings, diagrams and
supporting documents.

ACMS for CAT-I/Ⅱ Operation, Touch screen interface for ATCT and redundant PLC, located at the AGL
substion interconnected via a F.O network, Interface via Dual fieldbus with the CCRs, Neecessary I/O
for the connection of Aux, Equipment. Functionality: In the Control Tower south or Runway 11-29, ATCT
and Maintenance Workstation are Installed, Workstations are Installed, All workstations are connected by a fibre
optic loop, The functionality of the ACMS is control of lights on the Operator Workstations via control of the
monitoring/control units. Remote control and

monitoring, I/O Interface for CCR, Soft On/Off control, Brigtness control (5steps), Back indication of switched
controls/ selected brillinacy, Back indication of brilliancy error for each selected brilliancy, Indication of
shutdown due to over- current and work should be done as per design, drawing, specification of relevant
chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning of the following Digital Type Constant Current
Regulator (CCR) comprising of Input power 230V, 50Hz Output Current 6.6A; Remote On/Off, brightness
step 1 to 7 selector; Plug-in high voltage cut out type to isolate the series circuit from the regulator
output c/w 7C-1.5sqmm 0.6/1.0KV XLPE/PVC Screened Control Cable, Required 0.6/1.0KV XLPE/PVC
Power Cable of respective size etc works and likes for a complete installation and as per ICAO Part5, Chapter
3, 3.2.1.4/5/6 and work should be done as per design, drawing, specification of relevant chapter and
accepted by the Engineer.

In addition to the CCR Unit, the cost of the following sub-items shall include all the
associated works mentioned in this item
i) CCR 25 kW (by 1/C -35 Sqmm Power Cable)
ii) CCR 20 kW (by 1/C -35 Sqmm Power Cable)
iii) CCR 15 kW (by 1/C -25 Sqmm Power Cable)
iv) CCR 10 kW (by 1/C -16 Sqmm Power Cable)
v) CCR 7.5 kW (by 1/C -10 Sqmm Power Cable)
vi) CCR 4 kW (by 1/C -6 Sqmm Power Cable)

Supply, delivery, installation, testing and commissioning of Plug Cut Out Switch for the Digital Type Constant
Current Regulator (CCR) comprising of Serise cicrit 5kV 20A, Indoor Type; Withstands permanent 5 kV
A.C. circuit voltage etc works and likes for a complete installation and work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

Supply, delivery, installation, testing and commissioning of Series Plug Cut outs panel board for AGL Series
circuit; W2,000 x D450 XH1,1800 for COP (200mmx140mm), Door 3.2T, Front and Side 2.3T etc works and
likes for a complete installation and work should be done as per design, drawing, specification of relevant chapter
and accepted by the Engineer.

LT Distribution Board for CCR Station


Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following LT Switchboards. It shall also include protection relays, surge arrestors, electrical & signal
cabling, cable support, terminations, mounting, labelling, associated accessories and building works necessary to
provide the complete system as specified and complying with relevant codes, work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.

i) ACB 600V, 800A-2EA(LV-1,2); 400V, 3HP-4W, 50Hz; Condenser bank 20,15,10kVA, Digital
Meter & etc. SPD 3PH 4W, 50kA Mode, CT, etc

ii) CTTS 600V, 4P 1000AF(LV-3); 400V, 3HP-4W, 50Hz; Condenser bank


20,15,10kVA, Digital Meter & etc. SPD 3PH 4W, 50kA Mode, CT, etc with Interconnection.

iii) LV Distribution Panel(LV-4~6), LV Panel Board for AGL Power Supply, 600V,
3HP-4W, 50Hz, Digital Meter, MAIN ACB 4P 600AF - 1EA, Brench MCB 2P 225AF -
4EA , 2P100AF-4EA, ZCT, PT, CT, ELD 10CCT & etc.
iv) LV Distribution Panel(LV-SVC), Condenser bank 10kVAR*3, Digital Meter & etc,
600V, 3HP-4W, 50Hz, Digital Meter, MAIN ACB 4P 100AF - 1EA.
v) LV Distribution Panel(LV-FIL), ACTIVE FILTER 70A.
vi) Battery and Battery chager(LV-R), Encolse Lead-acid Battery type, 12V 9cells, Back
up 30min, Digital Meter.

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following Engine Generator Set as a complete system as specified and complying with relevant codes,
work should be done as per design, drawing, specification of relevant chapter and accepted by the Engineer.

i) Emergency Generator (GEN-1,2); 3Phase 4Wire 400kW/500kVA, Diesel 415/240V, 50Hz, 1,500rpm; with
Control Panel 2EA, Auto(D.C)Starting, MAIN ACB 4P 1200AF - 1EA, ACB 800A-2EA, Fuel daily tank 490L
x2ea and steel pipe lines, etc. Outer fuel tank 3,000L x 1ea & foundation.

Supply, delivery, installation, testing and commissioning, including all Airport Operation Readiness Trials for
the following PAD mounted Transformer Set i/c MCCBs, SPD, Elbow connector and foundation works
etc. The guaranteed values of finished articles will conform to the tolerances specified in ANSI C57. 12. 00
and as a complete system as specified and complying with relevant codes, work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.

i) 11kV/400/230V, 3Ø 4W, 50Hz. 45kVA,Outdoor Loop Type


ii) 11kV/400/230V, 3Ø 4W, 50Hz. 30kVA,Outdoor Loop Type
i) 230V/400V/11KV, 3Ø 4W, 50Hz. 45kVA,Outdoor Loop Type
ii) 230V/400V/11KV, 3Ø 4W, 50Hz. 30kVA,Outdoor Loop Type

Supply, delivery, installation, testing and commissioning of the following type of Luminaires, including all
cabling works with required Fiber Optic Control Cable in/c accessories, termination, concealed GI conduit,
junction box complete with quick male & female connector, supporting brackets and necessary accessories and
link to respective lighting switches on External including Control Panel Board, Base Foundation etc for
each mast pole and 01 no power tool against 02 nos mast pole etc. and work should be done as per design,
drawing, specification of relevant chapter and accepted by the Engineer.

Fixtures: LED Lamp not less than 400W x 3 and High Pressure Sodium 1kW with lamp
6x1000W & ballast.
Mast pole H=25M,(Up Down system)
Construction of Manhole & Pull Pit comprising of Hole Cover-iron, Excavation & Backfilling, Pulling-in
irons, Grounding rod,w/Clamp 18mmx2,400L-1EA, W/ Exothermic Connector, Tinned Bare copper
conductor, 16mm2-5M i/c related accessories and grounding material and work should be done as per
design, drawing, specification of relevant chapter and accepted by the Engineer.

i) TYPE-A(2.6M x 1.6M x 2.0M), Cable rack 6 arm (Manhole)


i) TYPE-B(1.6M x 1.3M x 1.1M), Cable rack 4 arm (Manhole)
i) TYPE-C(1.0M x 1.0M x 1.0M), Cable rack 2 arm (Pull Pit)

Duct Bank (Underground Ductbanks all in accordance) - work should be done as


per design, drawing, specification of relevant chapter and accepted by the Engineer.

Duct 20x100mm diameter(Type-EO1)


PVC 100mm X16, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
Concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 20x100mm diameter(Type-EO2)
PVC 100mm X18, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 18x100mm diameter(Type-EO3), Cross Part
PVC 100mm X16, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 16x100mm diameter(Type-EO4)
PVC 100mm X14, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 16x100mm diameter(Type-EO5), Cross Part
PVC 100mm X14, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 16x100mm diameter(Type-EO6)
PVC 100mm X12, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 16x100mm diameter(Type-EO7), Cross Part
PVC 100mm X12, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 12x100mm diameter(Type-EO8)
PVC 100mm X8, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 9x100mm diameter(Type-EO9)
PVC 100mm X7, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 8x100mm diameter(Type-E10)
PVC 100mm X7, PE 100mmX7(W/SCD25mmX5)X7
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 8x100mm diameter(Type-E11)
PVC 100mm X4, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 6x100mm diameter(Type-E12)
PVC 100mm X4, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 6x100mm diameter(Type-E13), Cross Part
PVC 100mm X4, PE 100mmX2(W/SCD25mmX5)X2
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, Rebar, etc
Duct 4x100mm diameter(Type-E14)
PVC 100mm X3, PE 100mmX1(W/SCD25mmX5)X1
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 4x100mm diameter(Type-E15)
PVC 100mm X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 4x100mm diameter(Type-E16), Cross Part
PVC 100mm X3, PE 100mmX1(W/SCD25mmX5)X1
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Duct 8x100mm diameter(Type-E17)
PVC 100mm X4, PE 100mmX4(W/SCD25mmX5)X4
PE Conduit. PVC 100mm, Coupling, spacer, warning tape
concrete 210mpa, Excavation & Backfilling
Form work (6 Time), Removable Compound
P.P Rofe 4mm, Duct marker, etc
Grounding & Counterpoise wire - work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
Duct Bank Section
i) Tinned copper BC 25Sqmm
ii) Earth Rod 18mm x2,400mm
iii) Bentonite 25kg/1Bag
AGL Section
i) Earthing wire Tinned copper BC16Sqmm
ii) Eatth Rod 18mm Sq x2,400mm
iii) Bentonite 25kg/1Bag
iv) Excavation & Backfilling
Grounding
Provision of earthing of equipment in the CCR hall along with testing point as per
drawing and as required.
AGL Lamp to lamp PE Pipes

Supply, delivery, installation of PE 54mm Pipe Conduit, PVC 54mm, Coupling, spacer, warning tape i/n concrete
210mpa, Excavation & Backfilling works and likes for a complete installation and work should be done as
per design, drawing, specification of relevant chapter and accepted by the Engineer.

Street Lighting

Supply, delivery, installation of Street lighting pole i/c lamp, auto control unit etc with waterproof type electric
shock protector(W/ELCB) and connecting material, conduit & foundation includes excavation & backfilling
works and work should be done as per design, drawing, specification of relevant chapter and accepted by the
Engineer.

i) Lighting ploe h=15m, steel 3.2t, HDG, LED lamp 400W x6


ii) Lighting ploe h=10m, 1arm, STS 304, LED lamp 150W x1
iii) Lighting ploe h=10m, 2arms, STS 304, LED lamp 150W x2
iv) Lighting ploe h=5m, STS 304, LED lamp 70W x2
v) Lighting Panel Board 6circuits, Stand Type & MCCB 4P 60A, ELCB 2P 20A-8,
Auto Control Unit, etc.
vi) Conduit FEP 65mm
vii) Conduit FEP 50mm
viii) Duct 4x100mm diameter(Type-E16), Cross Part
ix) Lighting 15M pole Foundation
x) Lighting 10M pole Foundation
xi) Lighting 5M pole Foundation
xii) Lighting Panel Board Foundation
CABLE WORKS

Supply, delivery, installation of the following cable and work should be done as per design, drawing,
specification of relevant chapter and accepted by the Engineer.
AGL Cable

Supply, delivery, installation of 5 KV XLPE primary cable as described in technical specification 1C- 6 sqmm and
plug receptacle with connection kit on under ground/through PVC pipe/ pavement/duct and work should be done
as per design, drawing, specification of relevant chapter and accepted by the Engineer.

Supply, delivery, installation of 600 KV 2 PNCT/PVC insulated, PVC sheathed cable 2C 4 sq mm including plug
and receptacle to connect fitting/transformer and work should be done as per design, drawing, specification of
relevant chapter and accepted by the Engineer.

NORMAL CABLE
15KV XLPE/PVC, 1/C- 35Sqmm
0.6/1kV XLPE/PVC, 1/C- 185Sqmm
0.6/1kV XLPE/PVC, 1/C- 120Sqmm
0.6/1kV XLPE/PVC, 1/C- 50Sqmm
0.6/1kV XLPE/PVC, 1/C- 25Sqmm
0.6/1kV XLPE/PVC, 1/C- 35Sqmm
0.6/1kV XLPE/PVC, 1/C- 16Sqmm
0.6/1kV XLPE/PVC/CVVS, 10/C- 1.5Sqmm
0.6/1.0KV XLPE/PVC, 1/C- 35Sq-4L
0.6/1.0KV XLPE/PVC, 1/C- 16Sq-2L
0.6/1.0KV XLPE/PVC, 1/C- 10Sq-2L
0.6/1.0KV XLPE/PVC, 2/C- 4Sq
GV wire, 1/C- 70Sqmm
GV wire, 1/C- 95Sqmm
GV wire, 1/C- 6Sqmm
Ground Copper wire 16sq
Ground Copper wire 10sq
Control Cable
F/O single mode 8C
Accessories
MV Terminal kit
MV Direct access Suplacing kit

CUTE SYSTEM

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the Common User Terminal Equipment System including all necessary cablings, termination and
accessories including wall, floor penetrations and re-sealed with approved fire stop material to the following :

CUTE Server with keyboard monitor, software, cabling and accessories


Fiber patch cord ( duplex) between core switches and fiber patch panel
High availability, load sharing, scalable Core Switches (Cisco 6500E equavalent) include ASA firewall
module and network management system module with accessories,
patch cables software and programming in comms room .
Interface with Airline Host Computer/Servers include programming, software, hardware
and accessories.
Interface with Local Departure Control System of Baggage Handling System include
programming, software, hardware and accessories.
Interface with Gate Management system (GMS) include programming, software,
hardware and accessories.
4 core Single Mode fiber optic link to airline host server (provision)
AOC
12 port managed Layer 2 edge switches (12 10/100 PoE port, 2 10/100/1000 PoE
ports and 2 dual purpose Gigabit SFP+ uplink ports), complete with all necessary interconnection and
accessories in AOC
Fiber patch cord (duplex) between fiber patch panel and edge switches
12 port UTP patch panel with accessories
UTP patch cord between edge switches and UTP patch panels
CAT 6 UTP cable between UTP patch panel and CUTE workstations with RJ45 face
plate (each less than 90m length)
CUTE monitoring and control workstation with software, cabling and accessories in
AOC/AFMCC room
Fibre optic converter in comms room & AOC room
8 core fiber optic link from fibre optic converter in Comms room to fibre optic converter
in AOC room (Provision)
Check-In Counter
48 port fiber patch panel with accessories
24 port stackable managed Layer 2 edge switches (24 10/100 PoE port, 2 10/100/1000 PoE
ports and 2 dual purpose Gigabit SFP+ uplink ports), complete with
all necessary interconnection and accessories.
Fiber patch cord (duplex) between fiber patch panel and edge switches
24 port UTP patch panel with accessories
UTP patch cord between edge switches and UTP patch panels
CAT 6 UTP cable between UTP patch panel and CUTE workstations with RJ45 face
plate (each less than 90m length)
CUTE workstation include software and programming and accessories
19" monitor
Baggage Tag Printer
Boarding Pass Printer
Bar Code Reader
Passport Reader (Magnetic Stripe/ Optical Character Recognition device)
general purpose/ document Printer
Self check-In Counter
CAT 6 UTP cable between UTP patch panel and CUSS workstations with RJ45 face
plate (each less than 90m length)
UTP patch cord between edge switches and UTP patch panels
CUSS workstation kiosk include software and programming and accessories
19" monitor
Baggage Tag Printer
Boarding Pass Printer
Bar Code Reader
Passport Reader (Magnetic Stripe/ Optical Character Recognition device)
Remote Management Module
Boarding Gate Counter
48 port fiber patch panel with accessories
12 port managed Layer 2 edge switches (12 10/100 PoE port, 2 10/100/1000 PoE ports and 2 dual
purpose Gigabit SFP+ uplink ports), complete with all necessary
interconnection and accessories.
Fiber patch cord (duplex) between fiber patch panel and edge switches
12 port UTP patch panel with accessories
UTP patch cord between edge switches and UTP patch panels
CAT 6 UTP cable between UTP patch panel and CUTE workstations with RJ45 Face
plate (each less than 90m length)
CUTE workstation include software and programming and accessories
19" monitor
Boarding Pass Reader
Boarding Pass Printer
Bar Code Reader
Passport Reader (Magnetic Stripe/ Optical Character Recognition device)
general purpose/ document Printer
Power point SSO including 2x 4mm2 1C PVC/PVC + 1C 4mm2 PVC E with cable support tapping from
nearest UDB located in Load Center (each csble length less than
80m)

LIGHTNING PROTECTION SYSTEM


Supply, delivery, installation, testing and commissioning of the Lightning Protection System including all
necessary lightning tapes, saddles, associated casting works into
columns or building and accessories to the following :
Test Link c/w Box
Bimetallic Connector
25mm x 3.25mm HC soft annealed Cu tape (Test Link to rebar Ground Slab)
25mm x 3.25mm HC soft annealed Cu tape (Down Conductor)
25mm x 3.25mm HC soft annealed Cu tape including clamp and exothermic bond (Roof
Cu tape)
Exothermic Weld or other approved method
Bonding Roof to downconductor
Bonding downconductor from Test Link Box to Ground Slab
0.5 m high air terminal
Grounding Earth Rods including bonding, connection , accessories with resistance , 10
Ohms at each earthing point
AIRPORT SIGNAGE SYSTEM

Providing & fitting / fixing of foreign made Signage panel (Image Carrier) of light- transmitting organic
board or light box cloth rigid polyurethane foam premixed polyether polyol, i/c proper base & surface (with the
back laminated by light-resistant film) of cast vinyl graphic film (minimum 2 mil) with a clear, permanent,
pressure-sensitive adhesive and a synthetic liner that does not split if wet. The matte surface finish eliminates glare
and provides a uniform color in both reflected and transmitted light. The film is thermoformable. The
system will be completed with LED lamp, tube, professional ballast, minimum 2mm acrylic lamp panel,
minimum 5mm acrylic plate i/c wireway (For image carrier) and the following content (in both Bengali &
English) i/c direction, symbol, icon etc as necessary (in film) and as per International Standard by maintaining
proper color coding (i/c user requirement) and completed as per derection by the Engineer-in-Charge

i) For Terminal and other buildings area.


ii) For Town Side Area
iii) Airport Name Signage in Town Side and Air Side.

Communication & Security Equipments


avigational Aid System
nection with Existing ILS/DME

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments including all necessary accessories, power cable, required civil and
electro-mechanical works etc. as per design, drawing, relavant specification and accepted by the Engineer.

RCSU, 1Station, 1RSU included RMM


- RMT Status Unit
- RCSU System
Fiber Optic Transmitting Unit included Radio Link
- 11 Localizer (Integrated Equipment Room to LOC Shelter)
- 11 GP/DME (Integrated Equipment Room to GP/DME Shelter)
RCSU and RSU Installation include accessories
Final Tune, Test and Flight Check Ground Support
Remote Control Cable , each Fiber Optic 6C, only material
- 11 Localizer (Integrated Equipment Room to LOC Shelter), 3682m
- 11 GS/DME (Integrated Equipment Room to GS/DME Shelter), 2075m
Remote Control Cable Installation for ILS/DME

t 6.1: Radio Navigational Aid System


2 DVOR
Supply of Dual DVOR 100 watt with co-located DME with shelter, antenna,
counterpoise complete with air-conditioning, wiring etc (as per specification)
Supply of Dual DME (as per specification)
Supply of RMMU & RSU including remote control cable (fiber optic )
Supply of spare parts for DVOR
Supply of spare parts for DME
Supply of Test equipment
Installation, Testing & Commissioning
Necessary E/M works at site under supervision by the Engineer – in – charge of the
concern E/M Division of CAAB

Necessary Civil works at per Drawing and Design (by manufacturer) at site under
supervision by the Engineer – in – charge of concern Civil Division of CAAB
Radio Earthing for item no 1 to 2(as per drawing & instruction of Engineer – in – charge)

avigational Aid System


3 Facilities for ATS Communication

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments including all necessary accessories, power cable, required civil and
electro-mechanical works etc. as per design, drawing, relavant specification and accepted by the Engineer.

VHF RADIO
VHF TX RADIO
- VHF Transmitter(50W, single), 10Set
- VHF cavity filter, 5Set
- VHF isolator, 5Set
- Standard Rack
- Main/Standby Changeover Unit, 5Set
- Other sub-assemblies (Cable and Others)
VHF RX RADIO
- VHF Receiver, 10Set
- Standard Rack
- Main/Standby Changeover Unit, 5Set
- Other sub-assemblies
VHF ANT
- VHF TX ANT & Assembly, 5Set
- Lighting surge arrestor of VHF TX ANT, 5Set
- VHF RX ANT & Assembly, 5Set
- Lighting surge arrestor of VHF RX ANT, 5Set
UPS-10kVA (included BATT.) (int the TX Station) (Back up time: 60minutes)
Portable Type VHF/UHF Multi-CH Transceiver ((in the ATCT and IECR)
SPARE PARTS
- Transmitter (50w)
- Receiver
- VHF cavity filter(dual)
- VHF isolator
- VHF TX ANT (included lightining surge arrestor)
- VHF RX ANT (included lightining surge arrestor)
- Main/Standby Changeover Unit
- Cavity filter
Packing and Transportation (CIP)
VHF RADIO Installation
VCCS
STVS
- Central Equipment & Interfaces_TED(6+2SP), Radio(5), Phone(40)
- Controller Working Positions, 6POS (ATCT Room-4, IECR-1, TX Room-1)
- Voice Communication Management System
- Other sub-assemblies (Cable and Others) including IDF
Recorder/Replay, 50ch dual
Digital Clock System with GPS ANT, Master-1, Slave-4
AMHS
- Server (Integrated Equipment Control Room-1)
- AMHS Terminal (ATCT Room-1, Weather Obs. Room-1, AMHS/Comm Room-3)
- AMHS RCMS (IECR-1)
UPS (included BATT.)
- 10kVA, in the Control Tower Room, 1Set (Back up time: 60mnts min.)
- 20kVA, in the Integrated Equipment Control Room, 1Set (Back up time: 60mnts)
Spare Parts
Test Equipment and Tools
- Communicaton Service Monitor
- Attenuator
- RF Power level meter
- VSWR tester
- Line level meter
Technician's tool
Packing and Transportation (CIP)
Flight Check Ground Support
ATIS
Main System
- Voice Synthesis Control System
- Voice Synthesis Processing System
- Remote Control Management System
- ATIS Terminal (Control Tower Room-1)
- ATIS Display Monitor (Control Tower Room-1)
- ATIS RCMS (IECR-1)
- HUB
- Modem
- Surge Protector
- Printer
- Voice Program
- Control Equipment Prom
- MIC
- Accessories (included 19" Rack)
Spare Parts
- Voice Synthesis Control System
- Voice Synthesis Processing System
- Voice Program
Packing and Transportation (CIP)
ATIS Installation
Datal Cable , UTP CAT.5-25PrX4, only material
- Integrated Equipment Control Room to Control Tower Room, 45m
Data Cable Installation
Remote Control Cable , Fiber Optic 6C, only material
- TX Station (Integrated Equipment Control Room to TX Station), 2155m
Remote Control Cable Installation for TX Station
Cable Tray, Aluminium w300xh150xt2.0mm
- Integrated Equipment Control Room, 35m
- Control Tower Room, 7m
- Roof Floor in the ATCT, 60m
- TX Equipment Control Room, 10m
- Roof Floor in the Fire Station, 23m
Console (Wood+Steel), only material
- Control Tower Room (H1068xW2100xD960)X4sets
- Integrated Equipment Control Room (H710xW3600xD1000)X1set
- TX Equipment Room (H710xW2400xD1000)X1set
Console Installation
Existing Facilities Demolition
- Control Console, Recorder, ANT and Rack included accessories

ommunication Equipments
FLIGHT INFORMATION DISPLAY SYSTEM
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of FIDS system including all necessary accessories, power cable, required
civil and electro-mechanical works (if any) etc. as per design, drawing, relavant specification and accepted by the
Engineer.
FIDS server with all required sofrware in main and hot standby configuration including
network printer as attached specification.
Data input terminal (DIT) with all required softwate as per specification.
Monitor 42 inch LED/TFT arrivel display monitor with embedded controller and necessory accessories to
install at different arrival area (out side and different floor) of
terminal building as per specification.

Monitor 55 inch LED/TFT Departure display monitor with embedded controller and necessory accessories
to install at different departure area. of terminal building as per
specification.

Monitor 42 inch LED/TFT Departure display monitor with embedded controller and necessory accessories
to install at different departure area. of terminal building as per
specification.

Baggage belt display Monitor 42 inch LED/TFT with embedded controller and necessory accessories to install at
different baggage area. of terminal building as per specification..

Checking counter display Monitor 32 inch LED/TFT with embedded controller and necessory accessories
to install at different checking area. of terminal building as per
specification.

Stuff monitor 22 inch LED/TFT including controller with numeric key pad. Stuff monitor should be program to
display deperture arrival and metrological information in different
pages.
Maitenance terminal with all accessories and required software as per specification.
Supply of minimum 6 core fiber optic cable, cat-6 cable and other necessary accessories
to complete whole connectivity of the system (as required).
Supply of Data switch (8/16/24 port), media converter, Tx Rx and etc to complete whole
connectivity and run of the system (as required).
10 KVA UPS with necessary accesoories for back power of main system and all Display
unit for uninteruppted operation of the system.
System match Electric power cable (standard rating), Circuit breaker, electric switch,
extension board and etc to provide electric power for whole system to run.
Standard table and chair (wooden made) for DIT.
SUB TOTAL
PABX
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of PABX system including all necessary accessories, power cable, required
civil and electro-mechanical works (if any) etc. as per design, drawing, relavant specification and accepted by the
Engineer.

Supply of PABX Call Server with redundancy (N+1) as per attached specification. Configuration:
IP Extension: 50
Analogue Extension: 50. Analogue Trunk line : 20 nos. E1 (ISDN PRI): 01.
Unified Messaging 32 Port Mailbox. 50
Call details recording (CDR) & Call Billing Software.

Supply, installation and configuration of media Gateway, switch and other related
modules for all nodes/unit as per requirement to successfully complete the project on turn key basis.

Supply installation and configuration of Analogue subscriber card for 50 nos. Analogue
Extension (as per attached specification).
Supply, installation and configuration of Trunk card for 20 nos. (as per attached
specification).
Supply, installation and configuration of E1 (ISDN PRI) card (as per attached
specification).
Supply installation and configuration of PC Based operator console with necessary
accessories (as per attached specification ).
Supply of IP Telephone Set (as per attached specification).
Supply of Analogue Telephone Set (as per attached specification ).
Supply installation and configuration of O&M Terminal (PC) with all necessary
accessories including standard network printer (as per attached specification).
Supply , installation and configure of Voice logger system with all necessary accessories
for call recording (as per attached specification).
Supply and installation of MDF& IDF with required Krone steeper as per requirement to successfully complete
the project on turn key basis. (as per attached specification).
Supply and installation of Earthing system with all accessories for Server unit, PC base
operator console, and O&M Terminal (PC) (as per attached specification ).
Supply and Installation of Charging unit (1+1) and Backup power system with maintenance free
Battery for Server unit, PC base operator console, and O&M
Terminal (PC).
Supply and installation of 04 pair Cable for IP phone connection in house (Terminal Building) as per
attached specification with direction of Engineer in charge.
Supply and installation of drop wire (01 pair, 0.9 mm) cable for Analogue extension/ phone connection
outdoor of Terminal Building as per direction of Engineer in charge.

Supply of all other accessories and equipment base furniture to install , fitting fixing
and programming of whole system as per requirement to successfully complete the project (from user end
to Call server) on turn key basis.

SUB TOTAL

Two Way Communication System:

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Two Way Communication System system including all necessary
accessories, power cable, required civil and electro-mechanical works (if any) etc. as per design, drawing,
relavant specification and accepted by the Engineer.

VHF Repeater system


VHF Repeater system (main and standby configaration) including change-over unit and
necessary accessaries as per attached specification.
Separate Tx/Rx Antenna for VHF Reapeter System
Antenna feeder cable conectors including installation kits
Tx/Rx Antenna Mast 40 feet
3 KVA online UPS with necessary power cable (as required) as power backup for
Repeater System.
VHF Walkie-Talkie
VHF Walkie-Talkie set with antenna belt clip, min 2200 mAh Lithiam-Ion battery
charger with adapter
6-Pocket multi charger unit
Spare battery min 2200 mAh Lithiam-Ion
Programming kits with necessary software including programming PC Core-i7, 1 T
HDD, 8 GB RAM etc.
VHF Transceiver
VHF Transceiver including micophone and other accessories as per attached
specification
VHF Transceiver Antenna, feeder cable, conectors including installation kits
Programming kits with necessary software including user and maintenace maunal
VHF Receiver Pannel
VHF Receiver as per attached specification
VHF Receiver Antenna, feeder cable, conectors including installation kits
DATIS Recorder and replay Unit
Standard DATIS Recorder and replay Unit
VHF Transmeter for DATIS including antenna as per attached specifiation
Digital Conference System
Central Control System Unit as per attached specification
Chairman Unit with Gooseneck microphone and head phone as per attached specification
Delegate Unit with Gooseneck microphone and head phone as per attached specification
Wireless Hand Held Microphone with recured accessories
Mixer Power Amplifier
20W Column Speaker with Stand
Compatible rack for Central Control Unit, Amplifier, etc.
3 KVA Online UPS, Backup time: 15 minutes (Minimum) on full load.
PC based recording system with required recording software as per specificaton.
Necessary accessories: Power extension board, Cable, Cable Tie, channel pipes, etc.
Standard Computer chair & table
Multimedia Projector with Motorized screen
Laptop Core-i7, 1 T HDD, 12 GB RAM etc

PUBLIC ADDRESS SYSTEM

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Public Address system including all necessary accessories, power
cable, required civil and electro-mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

In Comm. Equipment room


Fully Digital Audio Matrix & Central Processor Network Controller
FM/AM tunner complete with interconnecting cables and power supply
Multi disc DVD player and PC based MP3 player (main/stand by config) complete with
interconnecting cables and power supply
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
In AOC Level 1
Control monitoring PC with configuration/ diagnostic & logging software (in AOC)
6 Watt ceiling recessed/ surfaced mounted speaker
20 Watt horn speaker
6 Watt box speaker
60 Watt line array speaker
Basic Call Station (1channel) complete with cabling and accessories
Standard Call Station (10 channels) complete with cabling and accessories
Master Call Station (60 channels) complete with cabling and accessories for AOC and
FCC
60 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
125 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
250 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt fail safe auto change over redundant power amplifier complete with line
supervision set, Network Controller, interconnecting cables and power supply
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
Ambient Noise Sensors with controller for all passenger access area
4 Core Fire Rated (FR) Fibre Optic Cable with accessories and termination
Wiring with 2C x 14 AWG standard Fire Rated copper flexible wire including 1" dia GI conduit for music system
complete in all respects as per drawings and specifications.
In AOC Level 2
6 Watt ceiling recessed/ surfaced mounted speaker
20 Watt horn speaker
6 Watt box speaker
60 Watt line array speaker
Basic Call Station (1channel) complete with cabling and accessories
Standard Call Station (10 channels) complete with cabling and accessories
Master Call Station (60 channels) complete with cabling and accessories for AOC and
FCC
60 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
125 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
250 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt power amplifier complete with line supervision set, Network Controller,
interconnecting cables and power supply
500 Watt fail safe auto change over redundant power amplifier complete with line
supervision set, Network Controller, interconnecting cables and power supply
19" 42U equipment rack complete with power supply, ventilation fans and cable
management system.
Ambient Noise Sensors with controller for all passenger access area
4 Core Fire Rated (FR) Fibre Optic Cable with accessories and termination
Wiring with 2C x 14 AWG standard Fire Rated copper flexible wire including 1" dia GI conduit for music system
complete in all respects as per drawings and specifications.

CLOCK SYSTEM
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Clock system including all necessary accessories, power cable, required
civil and electro-mechanical works (if any) etc. as per design, drawing, relavant specification and accepted by the
Engineer.
Network Time Protocol Master clock system complete with software programming
(Duty and Standby)
Single sided digital clock
Design, supply, installation of all necessary accessories, supporting frames, C Channels, brackets for a complete
supporting system for clock in compliance with specification
Supply and installation of CAT 6 UTP cable from UTP Patch Panel located in ELV riser
to Clock point (The cable for each point should not exceed more than 90m.)
Signal Amplifiers for GPS signal on Roof
GPS antenna complete with lightning surge protection including bonding to earth
GPS receiver module with necessary interconnecting cables, cable support and rack
RG11 GPS antenna cables complete with cable support

STRUCTURE CABLING SYSTEM


Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of 2x24 core singlemode armoured fibre optic cable from fibre patch
panels in Comms room1 and Comm Rm 2
Supply, delivery, installation, testing and commissioning (which shall include all Airport
Operation Readiness Trials) of 2x24 port fibre patch panels, complete with all necessary interconnection
and accessories Comms Rm

Supply, delivery, installation, testing and commissioning of of Mass Cable Transit System (MCT) for
Telecommunication cables entry, inclusive of all associated accessories and building works necessary to
provide the complete system as specified and complying with relevant codes in the Terminal Building.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of 48 port stackable managed Layer 2 edge switches (48 10/100 PoE+ port, 2 10/100/1000 PoE ports
and 2 dual purpose Gigabit SFP+ uplink ports), complete with all necessary interconnection and accessories.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of 24 port stackable managed Layer 2 edge switches (24 10/100 PoE+ port, 2 10/100/1000 PoE ports
and 2 dual purpose Gigabit SFP+ uplink ports), complete with all necessary interconnection and accessories.

Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Primary and Secondary 48 port RJ45 Data/Voice UTP Patch Panels
including all necessary accessories
Supply, delivery, installation, testing, commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Primary and Secondary 24 port RJ45 Data/Voice UTP Patch Panels
including all necessary accessories
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Data Outlet (RJ45) including back box and all necessary
accessories as per drawings and specification

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of Voice/ Tel Outlet (RJ45) including back box and all
necessary accessories as per drawings and specification

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of IP telephone set.
Data point consist of CAT 6 UTP Voice/Data cable and conduit from riser UTP patch
panel to Outlet point (each does not exceed 90m)
Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) and defects liability maintenance of UTP patch cord
between edge switches and UTP patch panel (Data/ Voice Panel) in the riser
t 6.3: Security Equipments
Security Screening Equipment

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Security Screening system including all necessary accessories, power
cable, required civil and electro-mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Dual view X-Ray Scanning Machine with UPS, STP and necessory accessories (Cabine
baggage screening)
Dual view X-Ray Scanning Machine with UPS, STP and with necessory accessories (
Hold baggage screening)
Walk-Through Metal Detector with necessory accessories.
Hand Held Metal Detector
Under Vehicle Scanning System and Barrier Gate.

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of Under Vehicle Scanning System including all necessary accessories,
power cable, required civil and electro- mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Under Vehicle Scanning System (UVSS)


Barrier Gate with RFID Card Reader for Vehicle

CCTV Camera Survelliance System:

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments of CCTV Camera Survelliance System including all necessary accessories,
power cable, required civil and electro- mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Minimum 16 channel NVR (Network video recorder) with 42 inch LED monitor as per
specification.
Fixed (out door and indoor) IP IR camera as per specification.
PTZ (out door and indoor) IP IR camera as per specification.
Workstation with computer table and Off line 600 VA UPS (Back up time 30 mintes) as
per specification.
Optical fiber cable (06 core, 12 core), data cable (cat06 ) to comple connectivity of all
cameras inside and outside of terminal building. (as required)
10 KVA online Central UPS with necessary power cable (as required) for power
connectivity to all cameras inside and out side of terminal building.
IP switch as required and Compitible with system
Standerd size rack for containing of NVR
with minitor 42 inch.
Sub-Total (Communication and Security System)
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

Set 8

Set 126

Set 1

Set 6

No 6
No 2
No 1
No 2
No 1
No 9
No 3
No 1
No 8
No 83

No 6
No 2
No 1
No 2
No 1
No 9
No 3
No 1
No 6
No 1
No 1
No 1

Set 4
Set 2
Set 5
Set 3
Set 3
Set 6

No 23

No 1
No 2

No 1

No 3

No 1

No 1

No 1

No 2

No 2
No 2
No 2
No 2

No 20
No 66
No 66
No 7

M 231

M 293

M 164

M 385

M 232

M 2402
M 837

M 119

M 770

M 179

M 242

M 514

M 61

M 287

M 987
M 61

M 96

M 8150
No 54
Bag 26

M 10512
No 70
Bag 39
m3 31

lot 1

M 7067

No 8
No 139
No 5
No 53

No 5

M 48
M 14400
M 630
No 8
No 144
No 53
No 6
M 70700

M 2000

M 33451
M 1088
M 3748
M 908
M 622
M 1403
M 2831
M 110
M 1,080
M 14,228
M 2,456
M 2,618
M 545
M 120
M 450
M 4,291
M 1,032

M 5,048

KIT 42
KIT 39

lots 1
nos 19

nos 2

lot 1

lot 1

lot 1

m 1,000
no 1

no 2
no 1
no 2

no 2

no 2

nos 2

m 1,500

nos 1

nos 3

nos 6
nos 3
nos 36

nos 36

nos 36
nos 36
nos 36
nos 36
nos 36
nos 36
nos 6

no 2

nos 2
no 2
no 2
no 2
no 2
no 2
no 2
no 2

no 1

no 2

no 4
no 2
nos 8

no 8

no 4
no 4
no 4
no 4
no 4
no 4
nos 4

lot 1

No 40
No 40
M 2,000
M 2,000

M 4,000

No 40
No 40
No 100

No 100

Sqm 380
Sqm 200
Sqm 360

LOT 1
LOT 1

LOT 1
LOT 1
m 5,757

JOB 1

SET 1
SET 1
SET 1
SET 1
LOT 1
LOT 1
JOB 1

JOB 1

JOB 1
JOB 1

LOT 1

LOT 1

LOT 1

SET 1
SET 2
LOT 1
LOT 1
LOT 1

LOT 1

LOT 1
LOT 1
LOT 1

SET 2

LOT 1
LOT 1

LOT 1
LOT 1
LOT 1

LOT 1

LOT 1

LOT 1
LOT 1
m 45

LOT 1
m 2,155

LOT 1
m 135

SET 6

SET 6
JOB 1
-

nos. 2
nos. 4

nos. 20

nos. 4

nos. 35

nos. 6

nos. 8

nos. 10

nos. 2
lot 1

lot 1

nos. 2

job 1
set 5
set 1

lot 1

lot 1

lot 1

job 1

no. 1
nos. 50
nos. 50
no. 1

no. 1

job 1

job 1

job 1

job 1

lot 1

job 1

nos. 2
nos. 4
set 4
nos. 4
nos. 1

nos. 50
nos. 4
nos. 25
set 1

set 4
set 4
set 4

nos. 4
set 4

nos. 2
nos. 2

nos. 2
nos. 2
nos. 30
nos. 2
nos. 1
nos. 2
nos. 1
nos. 1
nos. 1
lot 1
Set
set 1
nos. 1

Lot 1
No 1
No 1

No 2

No 1
Nos 100
Nos 20
Nos 10
Nos 15
Nos 2
Nos 2
Nos 1

Nos 2

Nos 2

Nos 5

Nos 4

Nos 16

Nos 1
Nos 30
m 500
m 800

Nos 80
Nos 15
Nos 10
Nos 4
Nos 4
Nos 2
Nos 2

Nos 5

Nos 5

Nos 5

Nos 24

Nos 16

Nos 8
Nos 30
m 500
m 800

nos 2
nos 20
nos 20

nos 20
nos 2
nos 2
nos 2
lot 1

lot 2

no 2

lot 1

no 4

no 8

no 4

no 8

nos 50

nos 50

nos 50

nos 100

nos 100

nos. 12

nos. 12
nos. 24
nos. 55
Set 2
Set 2

nos. 15
nos. 150
nos. 30
nos. 10

lot 1

lot 1
job 1
nos. 5
Item No.

7
7.1

7.1.1

7.1.2

7.1.3

7.1.4

7.1.5

7.1.6
7.1.7
7.1.8
7.1.9

7.1.10
7.1.11
7.1.12
7.1.13

7.1.14

7.1.15
7.1.16
7.1.17

7.1.18

7.1.19

7.1.20

7.1.21
7.2
7.3
Description of Item

Construction of Fuel Hydrant Pipe line


JET A-1 Hydrant System

Supply, delivery, installation, testing and commissioning (which shall include all Airport Operation Readiness
Trials) of the following equipments for JET A-1 Hydrant System including all necessary accessories, power
cable, required civil and electro-mechanical works (if any) etc. as per design, drawing, relavant
specification and accepted by the Engineer.

Hydrant Pipeline Work with Internally Epoxy paint coated 40 Schedule Pipes (Seamless)
a) 10inch Diameter,Sch40 Seamless ASTEM A53 Gr.A Internal Epoxy Coated, External
Polyethlen lining
c) 6 inch Diameter, Sch 40 Seamless or API 5L Grade B Seamless PE COATED
d) 2 inch Diameter, PIPE, CS A106-B PE COATED SMLS BE B36.10M, S-80
Barred Tee /Reducer
a) Reducer Barred Tee (10 inch X 6 inch), TEE,CS 234 WPB SMLS BE
B16.9IMPACT TEST S-40 PE COATED
b) Barred Tee 10" x10" Equal Tee TEE,CS 234 WPB SMLS BE B16.9IMPACT TEST
S-40 S-40 PE COATED
c) Reducer (6 inch X 4 inch) Sch 40 x Sch 40 Seamless API 5L Grade B Seamless PE
COATED

Bends Sch 40
a) 10 inch Diameter 5D Bend Cold Bend 90 Deg ch 40 Seamless API 5L Grade B
Seamless PE COATED
b) 6 inch Diameter 5D Bend Cold Bend 90 Deg ch 40 Seamless API 5L Grade B
Seamless PE COATED
c) 6 inch Diameter 90 DEG ELL LR, CS A234-WPB-SMLS BE B16.9, S-40
Flanges:
a) 10 inch Diameter ND Flange: WNRF Class 150 A105 ANSI B16.5 for welding with
Pipe, Sch 40 Seamless or API 5L Grade B Seamless
b) 6 inch Diameter ND Flange: WNRF Class 150 A105 ANSI B16.5 for welding with
Pipe, Sch 40 Seamless or API 5L Grade B Seamless
c) 2 inch Diameter ND Flange: WNRF Class 150 A105 ANSI B16.5 for welding with
Pipe, Sch 40 Seamless or API 5L Grade B Seamless
Cast Steel Gate Valves:
a) 10 inch Diameter Gate Valve RF Class 150 ANSI B16.5
Emergency shut off stations
Aviation Grade Hose Couplings (2.5" dia)
Aviation Grade Hose Pipe with Couplings (2.5" dia, 20'-0" long)
Low point sump including valve (intermediate drain pit) Sampling unit for Vent or Drain
unit Including 20" pit and safety block valve
Hydrant Pit Valve #300 API 1584 3rd Edition Including 20"hydrant pit and safety block
valve
Distant Relay set
14" inch casing pipe Sch 40 Seamless or API 5L Grade B Seamless PE COATED
Providing pipe line coating/wrapping materials in/c. supplying of at as per standard
specification.

Providing cathodic protection including supply of materials for Cathodic Protection


works with Conductivity Survey and Test Result (3 Sets) as per standard Specification and Practice.

Line Cleaning & Drying PIG


a) 10 " Foam PIG
b) 6" Foam PIG
c) 10" Cup PIG
d) 6" Cup Pig
6" X 2" Weld-o-let,WELDOLET CS A105 BE/SW MSS-SP-97 IMPACT TEST S-40
X S-80
END CAP
6" End CAP,CS 234 WPB-SMLS BE B16.9M S-40
Blind Flange
a) 10" ND Blind Flanges : WNRF Class 150 A105 ANSI B16.5
Gasket: RF Class 150 for fitting in above Flanges
a) 10" GASKET 316 SS WND GRAPH FILL 316 SS 1/R CS O/R RF B16.20 CL150
4.5MM THK( 3.2 MM RING) SPR WND
Stud Bolt C/W 2HEX. Nuts A193 Gr. B7 /A194 Gr. 2H
a) 1 x 5 1/4"- Dia and LG should allow fitting in above 10" Valve & 10" Flange C/W
2HEX. Nuts A193 Gr. B7 /A194 Gr. 2H
Jet A1 Standard Turbine Flow Meter
Radiographic Testing of the whole hydrant system in/c. submission of report in 3 sets.
Testing, commissioning and obtaining a certificate from one of oil majors/preferable
Shell.
Sub-Total (Fuel Hydrant System)

Grand-Total
Unit Rate (Tk.) Amount (Tk.)
Unit Quantity
In figures In Words In figures In Words
3 4 5 6=5 7=4x5 8=7

Meter 2100.00
Meter 1300.00
Meter 300.00

Nos. 40.00

Nos. 3.00

Nos. 26.00

Nos. 25.00

Nos. 25.00
Nos. 7.00

Nos. 20.00

Nos. 5.00

Nos. 8.00

Nos. 9.00
Nos. 3.00
Nos. 10.00
Nos. 10.00
Nos. 8.00

Nos. 30.00
Nos. 1.00
Meter 400.00
Job 1.00

Job 1.00

Nos. 18.00
Nos. 6.00
Nos. 6.00
Nos. 2.00
Nos. 12.00

Nos. 8.00

Nos. 1.00

Nos. 50.00

Nos. 648.00
Nos. 1.00
Job 1.00
Job 1.00
280,000.00

Two Hundred And Eighty Thousand


PLEASE DO NOT WRITE ANY THING IN THIS SHEET;

- - 0.00 0.00
ET;

2.00 80.00 0.00


Two Eighty
Two Hundred And Eighty Thousand
0.00 0.00

S-ar putea să vă placă și