Sunteți pe pagina 1din 64

Power and Gas

We power the world with innovative gas turbines

siemens.com  / gasturbinesII
Gas turbines from
4 to 400 MW
The Siemens gas turbine range has been designed and
tailored to help meet our ­customers‘ ­challenges in a
dynamic market environment.
Our models range from 4 to 400 MW, fulfilling the
requirements of a wide spectrum of applications in terms
of efficiency, ­reliability, flexi­bility, and environmental
compa­­ti­bility.
The products offer low lifecycle costs and an excellent
return on investment.

SGT5-8000H 400 MW
50 Hz

gas turbines
SGT5-4000F 307 MW

Heavy-duty
SGT5-2000E 187 MW
SGT6-8000H 296 MW
60 Hz SGT6-5000F 242 MW
SGT6-2000E 116 MW
Ind. Trent 60 53 to 66 / 54 to 62 MW

Industrial and aeroderivative


SGT-800 48 to 53 MW
SGT-750 38 / 39 MW
SGT-700 33 / 34 MW
Ind. RB211 27 to 32 / 28 to 34 MW
50 Hz
or SGT-600 24 / 25 MW

60 Hz SGT-500 19 / 19 MW
gas turbines

SGT-400 13 to 14 / 13 to 15 MW
SGT-300 8 / 8 MW
SGT-200 7 / 8 MW
SGT-100 5 / 6 MW
Ind. 501 4 to 6 MW
Siemens gas turbines overview
[Power generation in MW(e) / Mechanical drive in MW]

SGT-500
SGT-600
Industrial 501 [4 to 6 MW] Industrial RB211
Heavy-duty SGT-100 [5/6 MW] SGT-700
gas turbines

SGT-200 [7/8 MW] SGT-750


SGT-300 [8/8 MW] SGT-800
Industrial
gas turbines SGT-400 [13 to 14 /13 to 15 MW] Industrial Trent 60

50 Hz and 60 Hz
Aeroderivative
gas turbines

Gas turbines in the range of Gas turbines in the range of

0–15 MW 16–99 MW
SGT6-2000E [116 MW]

[19/19 MW] SGT6-5000F [242 MW]


60 Hz
[24/25 MW] SGT6-8000H [296 MW]

[27 to 32/ 28 to 34 MW]

[33 / 34 MW] SGT5-2000E [187 MW]

[38 / 39 MW] SGT5-4000F [307 MW]


50 Hz
[48 to 53 MW] SGT5-8000H [400 MW]

[53 to 66/ 54 to 62 MW]

Gas turbines in the range of General note:


All simple cycle and mechanical drive performance data in

100–400 MW
this document are gross values at ISO ambient conditions.
All combined cycle performance data in this ­document are
net values at ISO ambient ­conditions, assuming 50 mbar
condenser pressure.
Table of
contents
Siemens gas turbines are suitable for a wide range
of applications:
Power generation application for utilities, independent
power producers, oil and gas, and industrial users,
such as chemicals, pulp and paper, food and beverage,
sugar, automotive, metalworking, mining, cement,
wood processing, and textiles.
Mechanical drive applications for oil and gas, and
chemical industry.

Heavy-duty gas turbines.................................................................6

Industrial gas turbines..................................................................28

Aeroderivative gas turbines...........................................................48

References...................................................................................56

Performance data overview..........................................................58


Heavy-duty
gas turbines
Siemens heavy-duty gas turbines are robust and
flexible engines, designed for large ­simple or
combined cycle power plants. They are suitable
for peak, i­ nter­mediate, or base load duty, as well
as for cogeneration applications.
Customers benefit from our extensive ­vali­dation
and testing capabilites.
Our engines are proven in ­commercial ­operation
and provide outstanding efficiency.

SGT5-8000H...................................................................................8

SGT6-8000H.................................................................................10

SGT5-4000F..................................................................................14

SGT6-5000F.................................................................................18

SGT5-2000E.................................................................................22

SGT6-2000E.................................................................................24
SGT5-8000H
Heavy-duty gas turbine

The SGT5-8000H offers outstanding performance and high The turbine is the core component of highly efficient
flexibility. With a gross power output of 400 MW, it is the ­gas-fired power plants, designed for 600 MW in combined
world’s most powerful gas turbine in commercial operation cycle operation, and combined cycle efficiencies of more
today. than 60%.
With more than 180,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
availability.

References

Düsseldorf Lausward,
Germany
Turnkey combined cycle power plant
Power output: 595 MW(e) and up
to 300 MW(th)
Customer: Stadtwerke Düsseldorf AG
Scope: SCC5-8000H 1S with
1 x SGT5-8000H gas turbine
package

Bandirma II, Cengiz, Turkey


Combined cycle power plant
Power output: 583 MW
Customer: Cengiz Enerji Samsun
Scope: SCC5-8000H with
1 x SGT5-8000H gas turbine
package for power island installation

Düsseldorf Lausward, Germany

8
Power output: 400 MW

„„ Outstanding performance
„„ High flexibility, short start-up times
„„ Proven in commercial operations

The SGT5-8000H achieves a world-class ­efficiency of more than 60% in combined cycle operations High operational flexibility due to world
class fast cold start and hot restart capability

Simple cycle power generation Combined cycle power generation

Power output 400 MW Siemens combined


1 × 1 2 × 1
cycle power plant
Fuel Natural gas, LNG, distillate oil, Arabian Super
Light crude oil, kerosene, condensate; other Net plant power output 600 MW 1,200 MW
­fuels on request
Net plant efficiency > 60% > 60%
Frequency 50 Hz
Net heat rate < 6,000 kJ/kWh < 6,000 kJ/kWh
Gross efficiency 40.0% (< 5,687 Btu/kWh) (< 5,687 Btu/kWh)

Heat rate 8,999 kJ/kWh (8,530 Btu/kWh) Number of gas turbines 1 2

Turbine speed 3,000 rpm Pressure/reheat Triple/Yes Triple/Yes

Pressure ratio 19.2 : 1

Exhaust mass flow 869 kg/s (1,915 lb/s) Physical dimensions

Exhaust temperature 627 °C (1,161 °F) Approx. weight 445,000 kg (981,000 lb)

NOx emissions < 25 ppmvd at 15% O2 on fuel gas Length 12.6 m (41 ft)
(without water injection for NOX control),
Width 5.5 m (18 ft)
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control) Height 5.5 m (18 ft)

9
SGT6-8000H
Heavy-duty gas turbine

The SGT6-8000H offers outstanding performance and high cycle operation with combined cycle efficiencies of more
flexibility. The air-cooled turbine with a gross power output than 60%.
of 296 MW is designed for simple and fast combined cycle
integration and short start-up times. With more than 180,000 fired hours, the SGT-8000H series
provides mature technology with verified reliability and
The turbine is the core component of highly efficient availability.
­gas-fired power plants, designed for 440 MW in combined

References

Riviera Beach, Florida, USA


Supply of gas turbine packages
Power output: 3 × 274 MW
Customer: Florida Power & Light
Scope: 3 × SGT6-8000H gas
turbine packages

Andong, South Korea


Power block for combined cycle
power plant
Power output: 416 MW
Customer: Korea Southern
Power Co. Ltd.
Scope: SCC6-8000H 1S with
1 x SGT6-8000H gas turbine

Dangjin 3, South Korea

10
Power output: 296 MW

„„ Outstanding performance
„„ High flexibility, short start-up times
„„ Proven in commercial operations

The blade design provides high efficiency and Valves allow for controlled cooling air supply, The SGT6-8000H can be easily integrated in
is ­designed to ensure high reliability with low to cover the needs of different o
­ perating single-shaft or multi-shaft combined cycle
outage risk conditions plants

Simple cycle power generation Combined cycle power generation

Power output 296 MW Siemens


combined
Fuel Natural gas, LNG, distillate oil, Arabian Super 1 × 1 2 × 1 3 × 1
cycle power
Light crude oil, kerosene, condensate; other plant
­fuels on request
Net plant 440 MW 880 MW 1,320 MW
Frequency 60 Hz power output
Gross efficiency 40% Net plant > 60% > 60% > 60%
Heat rate 8,999 kJ/kWh (8,530 Btu/kWh) efficiency

Turbine speed 3,600 rpm Net heat rate < 6,000 kJ/kWh < 6,000 kJ/kWh < 6,000 kJ/kWh
(< 5,687 Btu/kWh) (< 5,687 Btu/kWh) (< 5,687 Btu/kWh)
Pressure ratio 19.5 : 1
Number of 1 2 3
Exhaust mass flow 640 kg/s (1,410 lb/s) gas turbines
Exhaust temperature 630 °C (1,166 °F) Pressure/ Triple/Yes Triple/Yes Triple/Yes
reheat
NOx emissions < 25 ppmvd at 15% O2 on fuel gas
(without water injection for NOX control),
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOX control)

Physical dimensions

Approx. weight 289,000 kg (637,000 lb)

Length 10.5 m (34 ft)

Width 4.3 m (14 ft)

Height 4.3 m (14 ft)

11
Turbine

High cycling capability due to


fully internally air cooled
SGT-8000H series: Key features turbine section
3D four stage turbine with
advanced ­materials and thermal
barrier coating

Rotor Shorter outages:


All turbine vanes and blades
Proven rotor design (Hirth serration, replace­able ­without rotor lift;
central tie rod, internal cooling vane 1, blade 1 and 4 replaceable
air ­passages): For world class fast without cover lift
(cold) start and hot restart
capability
Easy rotor destacking on-site: Disc 4
assembly with Hirth serration and
­central tie rod

Compressor
2
Four stages of fast acting variable-
pitch guide vanes (VGV) allowing
for improved part load efficiency 3 5
and high load transients
Evolutionary 3D blading
Rotating blades replaceable without
rotor destack or lift

Combustion

Advanced can annular


combustion system
Bearings More than 60% combined cycle
efficiency
Hydraulic Clearance Optimization
(HCO) for reduced clearance losses
Transient protection of clearances
for reduced degradation with
HCO active clearance control
Flexibility Performance Serviceability
SGT5-4000F
Heavy-duty gas turbine

The proven SGT5-4000F gas turbine has a robust design Today, around 340 turbines have been sold. The installed
with internal cooling air passages for trusted long-term fleet has accumulated an impressive fleet experience of
operation and fast start-up capability. The advanced annular 11.5 million equivalent operating hours, and a fleet
combustion chamber with individually replaceable heat ­reliability of 99.2%.
shields allows for easy and fast walk-in maintenance.
Hydraulic Clearance Optimization (HCO) reduces clearance
losses to increase the gas turbine efficiency and minimize
degradation at start-up and shut down.

References

Kirishi, Russia
Supply of gas turbine packages
Power output: 800 MW
Customer: OGK-2 JSC, a subsidiary of
Gazprom Energo Holding OOO/LLC
Scope: Repowering project with
2 × SGT5-4000F gas turbine packages

Shuweihat S2, Abu Dhabi


Turnkey combined cycle power plant
Power output: 1,500 MW
Customer: Suez Energy Middle East
Scope: 2 × SCC5-4000F 2 × 1 with
4 × SGT5-4000F gas turbine packages

Al Taweelah, United Arab Emirates

14
Power output: 307 MW

„„ Proven design, large fleet


experience
„„ Easy maintenance, high availability
„„ High operational flexibility

The SGT5-4000F is a well-proven 50 Hz gas turbine Easy plant integration: Proven package For combined cycle applications, the
with an outstanding reliability and availability concepts for early power generation in simple SGT5-4000F is offered in single-shaft or
cycle operation; fast project execution multi-shaft (2 ×1) arrangements

Simple cycle power generation Combined cycle power generation

Power output 307 MW Siemens combined


1S 2 × 1
cycle power plant
Fuel Natural gas, LNG, ethane, propane, distillate oil
(dual fuel option); other fuels on request Net plant power output 445 MW 890 MW

Frequency 50 Hz Net plant efficiency 58.7% 58.7%

Gross efficiency 40.0% Net heat rate 6,133 kJ/kWh 6,133 kJ/kWh
(5,812 Btu/kWh) (5,812 Btu/kWh)
Heat rate 9,001 kJ/kWh (8,532 Btu/kWh)
Number of gas 1 2
Turbine speed 3,000 rpm turbines
Pressure ratio 18.8 : 1 Pressure/reheat Triple/Yes Triple/Yes
Exhaust mass flow 723 kg/s (1,595 lb/s)

Exhaust temperature 579 °C (1,074 °F)


Physical dimensions
NOx emissions < 25 ppmvd at 15% O2 on fuel gas
(without water injection for NOX control), Approx. weight 312,000 kg (688,000 lb)
< 42 ppmvd at 15% O2 on fuel oil
Length 10.8 m (35 ft)
(with water injection for NOX control),
< 58 ppmvd at 15% O2 on fuel oil Width 5.2 m (17 ft)
(without water injection for NOX control)
Height 4.8 m (16 ft)

15
Combustion System

Low NOx burners, for dry operation


with gaseous & liquid fuels
SGT5-4000F: Key features Homogeneous outlet profile for
minimized mechanical and
thermal turbine stress
Rotor
Annular chamber with individually

Robust design with internal 4 replaceable heat shields for easy


and fast walk-in maintenance
cooling air passages for trusted
long term operation and fast
start-up capability
Easy de-stacking on-site due to
Hirth serration and central tie
rod 1 5

HCO
2 3
Improved performance
and minimized d ­ e­gradation by
active control of clearances at
start-up and shut down

Turbine

High cycling capability due to


fully air cooled hot gas path
without cooling air coolers
Four stages with film cooling
Compressor and thermal barrier coatings for
well balanced turbine load and
low lifecycle costs
Proven design
Rotating blades of all 15 stages
replaceable without rotor lift

Flexibility Performance Serviceability


SGT6-5000F
Heavy-duty gas turbine

The SGT6-5000F gas turbine offers economical power Today, around 370 turbines have been sold. The installed
generation with fast start-up for peak, intermediate, or fleet has accumulated more than 11 million equivalent
base l­oad duty. It achieves peak values for reliability and operating hours, with a fleet reliability of 99.2%.
continuous operation with highest performance values
in its class.

References

Ras Al-Khair, Saudi Arabia


Supply of gas turbine packages
Power output: 2,400 MW
Customer: Consortium comprising
Al Arrab Contracting Company,
Saudi Arabia and the Chinese Sep-
coII Electric Power Construction
Corporation
Scope: 12 × SGT6-5000F gas turbine
packages

Marsh Landing, USA


Power block for open cycle power
plant
Power output: 720 MW
Customer: NRG Energy
Scope: SCC6-5000F with 4 ×
SGT6-5000F gas turbine packages

La Caridad, Sonora, Mexico

18
Power output: 242 MW

„„ Highest power output for 60 Hz


F-class
„„ Fast start-up and load changing
capabilities
„„ Low emissions with NOx emissions of
< 9 ppm on gas and < 25 ppm on oil

The SGT6-5000F offers world class reliability and best in class ­emission values The SGT6-5000F is the first choice for reliable simple
or combined cycle operation in the 60 Hz market

Simple cycle power generation Combined cycle power generation

Power output 242 MW Siemens combined


1 × 1 2 × 1
cycle power plant
Fuel Natural gas, LNG, syngas, ethane, propane,
condensate, distillate oil, Arabian Super Light Net plant power output 360 MW 725 MW
crude oil, Arabian Extra Light crude oil, bio-
Net plant efficiency 58.1% 58.6%
diesel, alcohols, Jet-A oil, kerosene
Net heat rate 6,193 kJ/kWh 6,138 kJ/kWh
Frequency 60 Hz
(5,870 Btu/kWh) (5,817 Btu/kWh)
Gross efficiency 39.0%
Number of gas turbines 1 2
Heat rate 9,230 kJ/kWh (8,748 Btu/kWh)
Pressure/reheat Triple/Yes Triple/Yes
Turbine speed 3,600 rpm

Pressure ratio 18.9 : 1


Physical dimensions
Exhaust mass flow 576 kg/s (1,270 lb/s)
Approx. weight 219,000 kg (482,000 lb)
Exhaust temperature 600 °C (1,113 °F)
Length 10.1 m (33 ft)
NOx emissions < 9 ppmvd at 15% O2 on fuel gas
Width 4.0 m (13 ft)
(without water injection for NOx control),
< 25 ppmvd at 15% O2 on fuel oil Height 4.6 m (15 ft)
(with water injection for NOx control)
Combined cycle plant turn down in emissions compliance to 20% load.
Gas turbine turn down in emissions compliance
to 30% load. Fast start-up capable of generating
200 MW in 10 minutes from turning gear speed.
Gas turbine ramp rate up to 40 MW/min.

19
Turbine

Four stage turbine with


proven conventionally cast
SGT6-5000F: Key features turbine alloys
Low firing temperature for
long service intervals

Combustion

Fuel flexible and proven Ultra


Low NOx combustion system

Single digit emissions down to


30% load
4
3

Rotor

Single tie rod with Hirth


Compressor serrations for reliable torque
transmission
Variable guide vanes for part External rotor air cooler for
load efficiency and transient constant cooling air temperature
operation across the ­ambient range
Blades and vanes removable
without a rotor de-stack or lift

Flexibility Performance Serviceability


SGT5-2000E
Heavy-duty gas turbine

The SGT5-2000E gas turbine is a proven, robust engine for high viscosity. It provides low NOx emissions, even in the
the 50 Hz market which is used in simple cycle or combined part load range.
cycle processes with or without combined heat and power.
It is suitable for all load ranges, including peak load. Today, around 480 turbines have been sold (approx. 220
under license). Our installed fleet has accumulated more
The SGT5-2000E offers outstanding fuel flexibility. It can be than 17 million equivalent operating hours. The SGT-2000E
fired with low calorific gases or gases containing CO2, H2S series fleet´s overall best-in-class r­ eliability exceeds 99%.
and N2, as well as with crude oil and other liquid fuels with

References

Braemar 2, Australia
Power block for open cycle power
plant
Power output: 450 MW
Customer: ERM Power
Scope: 3 × SGT5-2000E gas turbine
packages

Geregu 2, Nigeria
Turnkey open cycle power plant
Power output: 434 MW
Customer: Niger Delta Power
Holding Company
Scope: 3 × SGT5-2000E gas turbine
packages

Az-Zour, Kuwait

22
Power output: 187 MW

„„ Best-in-class reliability
„„ High operational and fuel flexibility
„„ Easy maintenance

Best-in-class reliable technology; robust and flexible performance Service-friendly design and customer-focused maintenance intervals
help to keep life cycle costs down

Simple cycle power generation Combined cycle power generation

Power output 187 MW Siemens combined


1 × 1 2 × 1
cycle power plant
Fuel Natural gas, LNG, syngas, blast furnace gas,
biogas, ethane, propane, condensate, distillate Net plant power output 275 MW 551 MW
oil, heavy and crude oils, bio-diesel, alcohols,
Net plant efficiency 53.3% 53.3%
naphtha, kerosene
Net heat rate 6,755 kJ/kWh 6,755 kJ/kWh
Frequency 50 Hz
(6,403 Btu/kWh) (6,403 Btu/kWh)
Gross efficiency 36.2%
Number of gas turbines 1 2
Heat rate 9,945 kJ/kWh (9,427 Btu/kWh)
Pressure/reheat Dual/No Dual/No
Turbine speed 3,000 rpm

Pressure ratio 12.1 : 1

Exhaust mass flow 558 kg/s (1,230 lb/s) Physical dimensions

Exhaust temperature 536 °C (997 °F) Approx. weight 189,000 kg (417,000 lb)

NOX emissions < 25 ppmvd at 15% O2 on fuel gas Length 10.3 m (34 ft)
(without water injection for NOx control),
Width 4.0 m (13 ft)
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control) Height 4.0 m (13 ft)

23
SGT6-2000E
Heavy-duty gas turbine

The SGT6-2000E gas turbine is a proven, robust engine for fuels with high viscosity. It provides low NOx emissions,
the 60 Hz market which is used in simple cycle or combined even in the part load range.
cycle processes with or without combined heat and power
supply. It is suitable for all load ranges, including peak load. Today, around 110 turbines have been sold, resulting in
The SGT6-2000E offers outstanding fuel flexibility. a fleet experience of nearly 7 million equivalent operating
hours. The SGT-2000E series fleet´s overall best-in-class
It can be fired with low calorific gases or gases containing reliability constantly exceeds 99%.
CO2, H2S and N2, as well as with crude oil and other liquid

References

Hsinta, Taiwan
Combined cycle power plant
Power output: 2,200 MW
Customer: Taiwan Power Company
Scope: 5 × SCC6-2000E 3 × 1 with
15 × SGT6-2000E gas turbine
packages

Shoaiba, Saudi Arabia


Most powerful and efficient crude
oil plant in the world
Power output: 1,200 MW
Customer: Saudi Electricity Company
Scope: 2 × SCC6-2000E 5 × 1 with
10 × SGT6-2000E gas turbine
packages

Charles D. Lamb Energy Center, Oklahoma, USA

24
Power output: 116 MW

„„ Best-in-class reliability
„„ High operational and fuel flexibility
„„ Easy maintenance

Two accessible silo combustion chambers for easy Variable inlet guide vanes (IGV); all Excellent start-up and part load behavior,
maintenance; ceramic tiles can be replaced individually rotating blades replaceable without rotor at 30 MW/ min ramp rate
de-stack or lift

Simple cycle power generation Combined cycle power generation

Power output 116 MW Siemens combined


1 × 1 2 × 1
cycle power plant
Fuel Natural gas, LNG, syngas, blast furnace gas,
biogas, ethane, propane, condensate, distillate Net plant power output 171 MW 342 MW
oil, heavy and crude oils, bio-diesel, alcohols,
Net plant efficiency 51.3% 52.0%
naphtha, kerosene
Net heat rate 7,018 kJ/kWh 6,923 kJ/kWh
Frequency 60 Hz
(6,651 Btu/kWh) (6,561 Btu/kWh)
Gross efficiency 34.3%
Number of gas turbines 1 2
Heat rate 10,496 kJ/kWh (9,949 Btu/kWh)
Pressure/reheat Dual/No Dual/No
Turbine speed 3,600 rpm

Pressure ratio 12.1 : 1

Exhaust mass flow 367 kg/s (809 lb/s) Physical dimensions

Exhaust temperature 537 °C (999 °F) Approx. weight 108,000 kg (239,000 lb)

NOx emissions < 25 ppmvd at 15% O2 on fuel gas Length 9.1 m (30 ft)
(without water injection for NOx control),
Width 3.3 m (11 ft)
< 42 ppmvd at 15% O2 on fuel oil
(with water injection for NOx control) Height 3.3 m (11 ft )

25
Compressor

SGT-2000E series: Key features Emission-compliant operation down to


45% at constant exhaust temperature
Fast-acting variable inlet guide vanes
for grid frequency stabilization
All rotating blades replaceable without
rotor de-stack/lift

Combustion
1
Full fuel flexibility, ranging from heavy
fuel oil to low calorific gases
Axial Exhaust
Two easily accessible silo combustion
chambers for fast maintenance Cold end generator drive for
Lining with ceramic tiles which can be optimal flow pattern
replaced individually 4

5
Rotor and Bearings
2 3
Transient protection of clearances for
reduced degradation with Hydraulic
­Clearance Optimization (HCO) active
­clearance control
Light-weight, highly rigid design with
excellent start-up performance

Built disc-type rotor with radial Hirth


serrations and one central tie rod,
rotor de-stacking on-site

Turbine

Four stage turbine, blades and vanes


with Si3D design for enhanced
performance

Flexibility Performance Serviceability


27
Industrial
gas turbines
The industrial gas turbine models with their compact
and rugged design make them an ideal choice for
both i­ ndustrial power generation and mechanical
drive applications.
Their high steam-raising capabilities help achieve
overall plant efficiency of 80 percent or higher.
They are proven with more than 2,250 units sold at
small utilities, independent power producers, and in
the oil and gas industry.

SGT-800...........................................................................................30

SGT-750...........................................................................................32

SGT-700...........................................................................................34

SGT-600...........................................................................................36

SGT-500...........................................................................................38

SGT-400...........................................................................................40

SGT-300...........................................................................................42

SGT-200...........................................................................................44

SGT-100...........................................................................................46
SGT-800
Industrial gas turbine

The SGT-800 industrial gas turbine offers broad flexibility The SGT-800 combines a simple, robust design, for high
in fuels, operating conditions, maintenance concepts, reliability and easy maintenance, with high efficiency
package solutions, and ratings. and low emissions. With a proven, long-term record of
The excellent efficiency and steam-raising capability successful installations around the world, the SGT-800 is
make it outstanding in cogeneration and combined cycle an ­excellent choice for power generation for industrial
installa­tions. The SGT-800-based power plant, designed and oil and gas applications.
for flexible operation, is perfectly suited as grid support.

References

Amata Nakorn, Thailand


Combined cycle cogeneration
power plants
Customer: Amata B. Grimm
Power Limited (ABP)
Scope: 12 × SGT-800 gas turbines
and 9 × SST-400 steam turbines

Hassi R‘mel, Algeria


Combined cycle power plant
Customer: Abengoa
Scope: 2 × SGT-800 gas turbines
and 1 × SST-600 steam turbine

Two SGT-800 packages at Amata Nakorn, Chonburi, Thailand

30
Power generation:
47.5/50.5/53.0 MW(e)
„„ Proven reliability
„„ Flexible solution
„„ Excellent performance

SGT-800 core engine is available in three ratings with Classic package – easily transported and Single lift package – short installation and com-
standard options for hot and cold climates ­installed at site, easy on-site maintenance missioning time at site; U.S. adapted version

Physical dimensions
Simple cycle power generation
Classic package Single lift package
47.5 MW version 50.5 MW version 53.0 MW version
Approx. 290,000 kg 320,000 kg
Power output 47.5 MW(e) 50.5 MW(e) 53.0 MW(e) weight (617,300 lb) (705,500 lb)

Frequency 50/60 Hz 50/60 Hz 50/60 Hz Length 27.9 m (91 ft) 19.6 m (64 ft)

Gross efficiency 37.7% 38.3% 39.0% Width 7.3 m (24 ft) 4.7 m (15 ft)

Heat rate 9,547 kJ/kWh 9,389 kJ/kWh 9,231 kJ/kWh Height 15.1 m (49 ft) 15.3 m (50 ft)

Turbine speed 6,608 rpm 6,608 rpm 6,608 rpm

Pressure ratio 20.1 : 1 21.0 : 1 21.4 : 1

Exhaust gas flow 132.8 kg/s 134.2 kg/s 137.2 kg/s

Exhaust gas temperature 541 °C (1,007 °F) 553 °C (1,027 °F) 551 °C (1,024 °F)

NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

1 × 1 Combined cycle power plant

Net plant output 66.6 MW(e) 71.4 MW(e) 74.0 MW(e)

Net plant efficiency 53.8% 55.1% 55.6%

Net plant heat rate 6,693 kJ/kWh 6,530 kJ/kWh 6,475 kJ/kWh

Number of gas turbines 1 1 1

2 × 1 Combined cycle power plant


Note: Standard design; ISO ambient conditions. No intake or exhaust loss.
Net plant output 135.4 MW(e) 143.6 MW(e) 150.0 MW(e) Fuel: Natural gas. Options available for other gases within specification
and dual fuel with gas and Diesel no 2.
Net plant efficiency 54.7% 55.4% 56.2% The combined cycle plant SCC-800 is also available based on more than
two SGT-800. All combined cycle performance is based on 2 pressure,
Net plant heat rate 6,583 kJ/kWh 6,494 kJ/kWh 6,406 kJ/kWh no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 2 2 2 generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

31
SGT-750
Industrial gas turbine

With maximized uptime, top-class performance, and a low It combines a robust, reliable design with high efficiency
environmental footprint offering the customer high lifetime and low emissions.
profitability, the SGT-750 industrial gas turbine is a perfect
choice for the oil and gas industry as well as industrial The SGT-750 has a track record of proven and verified
power generation. results after years in operation and several references in
both power generation and mechanical drive applications
The modular and flexible engine enables onshore or ­offshore such as pipeline and liquefied natural gas (LNG).
applications, mechanical drive or heat and power.

References

Kaltex Altamira, Mexico


Combined heat and power plant
Customer: Energia MK KF, S.A. de C.V.
Scope: 1 x SGT-750 gas turbine

Greifswald Wingas, Germany


Combined heat and power plant
Customer: Industriekraftwerk
Greifs­wald GmbH, Lubmin
Scope: 1 x SGT-750 gas turbine,
auto­mation & control for landfall
station

SGT-750 combined heat and power plant in Altamira, Mexico

32
Power generation: 38.1 MW(e)
Mechanical drive: 39.3 MW
„„ Maximized uptime
„„ High efficiency
„„ Low emissions

SGT-750 core engine with a free high-speed power Power generation package – O&G mechanical drive package for on- or
turbine also available as single lift offshore applications – also as single lift

Simple cycle power generation Mechanical drive applications

Power output 38.1 MW(e) 39.3 MW

Fuel Natural gas Natural gas

Frequency 50/60 Hz

Gross efficiency 40.2% 41.45%

Heat rate 8,953 kJ/kWh 8,685 kJ/kWh

Turbine speed 6,100 rpm 6,100 rpm

Pressure ratio 23.8 : 1 23.8 : 1

Exhaust gas flow ~ 113.8 kg/s ~ 113.8 kg/s

Exhaust temperature 458.1 °C (856.5 °F) 458.1 °C (856.5 °F)

NOx emissions < 15 ppmvd at 15% O2 on fuel gas (with DLE) <15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation Physical dimensions

Siemens combined SCC-750 1 × 1 SCC-750 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx. 175,000 kg (385,809 lb) 76,000 kg (167,551 lb)
Net power output 49.4 MW(e) 99.4 MW(e) weight

Net plant efficiency 52.1% 52.7% Length 20.3 m (66.6 ft) 12.3 m (40.35 ft)

Net heat rate 6,946 kJ/kWh 6,898 kJ/kWh Width 4.8 m (15.75 ft) 4.3 m (14.11 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 1 2 Height 4.1 m (13.45 ft) 4.1 m (13.45 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

33
SGT-700
Industrial gas turbine

Thanks to its wide fuel range capability and design features, The SGT-700 gas turbine is an evolution of the proven
the SGT-700 is a perfect choice for several onshore applications: ­SGT-600 and is specifically designed for higher power
Industrial power generation, oil and gas power ­generation, ­output. It offers easy on-site or off-site maintenance and
and mechanical drive applications. operates with a wide range of gaseous and liquid fuels
It performs well in combined cycle plants and combined heat on Dry Low Emission (DLE).
and power plants. More than 70 units have been sold with 1.2 million
equi­valent operating hours, and 78,000 equivalent
operating hours for the fleet-leading gas turbine.

References

Tianjin Bohai, China


Onshore simple cycle propane
­dehydrogenation (PDH) plant
Customer: Tianjin Bohai Chemical
Industry Group
Scope: 2 × SGT-700 gas turbines and
2 × axial flow compressors

Pinghu/Satellite Energy
450 KTA, China
Onshore simple cycle propane
­dehydrogenation (PDH) plant
Customer: Zhejiang Satellite Energy
Co., Ltd
Scope: 1 x SGT-700 gas turbine coupled
with 1 x 25 MW compressor

Three SGT-700 packages for mechanical drive

34
Power generation: 32.8 MW(e)
Mechanical drive: 33.7 MW
„„ Robust, reliable design
„„ High fuel flexibility
„„ Low emissions

Maintainable, reliable, and robust twin-shaft design for mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same

Simple cycle power generation Mechanical drive applications

Power output 32.8 MW(e) 33.7 MW

Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel

Frequency 50/60 Hz

Gross efficiency 37.2% 38.2%

Heat rate 9,675 kJ/kWh 9,424 kJ/kWh

Turbine speed 6,500 rpm 6,500 rpm

Pressure ratio 18.7 : 1 18.7 : 1

Exhaust gas flow 95 kg/s 95 kg/s

Exhaust temperature 533 °C (991 °F) 533 °C (991 °F )

NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation Physical dimensions

Siemens combined SCC-700 1 × 1 SCC-700 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 45.2 MW 91.6 MW weight 169,000 kg (372,581 lb) 63,000 kg (138,891 lb)

Net plant efficiency 52.3% 53.1% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft)

Net heat rate 6,876 kJ/kWh 6,778 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 1 2 Height 5.8 m (19.03 ft) 5.8 m (19.03 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

35
SGT-600
Industrial gas turbine

High reliability and availability in combination with good The industrial gas turbine combines a robust, reliable
fuel flexibility and third-generation DLE makes the SGT-600 design with high fuel flexibility and low emissions.
a perfect choice for several onshore applications:
Industrial power generation, oil and gas power generation, More than 330 units have been sold with over 9 million
and mechanical drive applications. Within the IPG applications, equi­valent operating hours, and 185,000 equivalent
the turbine performs well in combined heat and power ­ope­rating hours for the fleet-leading gas turbine.
plants and combined cycle plants.

References

Bahia Blanca, Argentina


Combined heat and power
Customer: Profertil S.A.
Scope: 1 x SGT-600 gas turbine,
STC-GV (80-6) compressor, generator,
NEM heat recovery steam generator

Tiszaújváros, Hungary
Combined cycle power plant
Customer: TVK Ltd
Scope: 1 x SGT-600 gas turbine and
1 x SST-700 steam turbine

SGT-600 installation for both ­mechanical drive and power generation

36
Power generation: 24.5 MW(e)
Mechanical drive: 25.3 MW
„„ Robust, reliable design
„„ High fuel flexibility
„„ Low emissions

Maintainable, reliable, and robust twin-shaft design for ­mechanical drive and For both power generation and mechanical drive package,
power generation the driver is the same

Simple cycle power generation Mechanical drive applications

Power output 24.5 MW(e) 25.3 MW

Fuel Natural gas, liquid fuel, dual fuel Natural gas, liquid fuel, dual fuel

Frequency 50/60 Hz

Gross efficiency 33.6% 34.6%

Heat rate 10,720 kJ/kWh 10,390 kJ/kWh

Turbine speed 7,700 rpm 7,700 rpm

Pressure ratio 14.0 : 1 14.0 : 1

Exhaust gas flow 81.3 kg/s 81.3 kg/s

Exhaust temperature 543 °C (1,009 °F) 543 °C (1,009 °F)

NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation Physical dimensions

Siemens combined SCC-600 1 × 1 SCC-600 2 × 1 Power generation package Mechanical drive package
cycle power plant
Approx.
Net power output 35.9 MW(e) 73.3 MW(e) weight 150,000 kg (330,693 lb) 59,000 kg (130,072 lb)

Net plant efficiency 49.9% 50.9% Length 18.8 m (61.68 ft) 11.7 m (38.38 ft)

Net heat rate 7,220 kJ/kWh 7,071 kJ/kWh Width 4.6 m (15.09 ft) 4.0 m (13.12 ft) Note: All combined cycle is based on 2 pressure, no reheat.
Dimensions exclude inlet filter housing and exhaust stack. For power
Number of gas turbines 1 2 Height 5.8 m (19.03 ft) 5.8 m (19.03 ft) generation, AC generator is included. For mechanical drive, driven
equipment is excluded.

37
SGT-500
Industrial gas turbine

Combining high overall efficiency and low maintenance burning heavy fuel oils (HFO), naphtha, and hydrogen
costs with long intervals between overhauls, the SGT-500 gases.
is positioned well for oil and gas power generation and
mechanical drive applications both onshore and offshore. More than 175 units have been sold with over 9 million
equivalent operating hours.
In addition to its proven, robust, and reliable design, the
SGT-500 has excellent fuel flexibility with the capability of

References

BUA Okpella cement plant,


Nigeria
Simple cycle power plant
Customer: BUA International Ltd.
Scope: 3 × SGT-500 gas turbines
High returns thanks to low
investment and operating costs,
excellent fuel flexibility, fuel
changeover on load

Two SGT-500 installations on an FPSO

38
Power generation: 19.1 MW(e)
Mechanical drive: 19.3 MW
„„ Fuel flexibility
„„ Proven design
„„ Easily maintained

SGT-500 core engine – proven and robust design SGT-500 offshore package – compact and
easily maintained

Simple cycle power generation Mechanical drive applications

Power output 19.1 MW(e) 19.3 MW

Fuel Natural gas, liquid, dual, HFO, crude oil Natural gas, liquid, dual, HFO, crude oil

Frequency 50/60 Hz

Gross efficiency 33.8% 34.5%

Heat rate 10,690 kJ/kWh 10,530 kJ/kWh

Turbine speed 3,600 rpm 3,450 rpm

Pressure ratio 13.0 : 1 13.0 : 1

Exhaust gas flow 97.9 kg/s 97.9 kg/s

Exhaust temperature 369 °C (697 °F) 369 °C (697 °F)

NOx emissions ≤ 42 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 42 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 210,000 kg (462,970 lb) 71,000 kg (176,000 lb)

Length 20.6 m (67.6 ft) 14.1 m (46 ft)

Width 4.0 m (13.1 ft) 4.0 m (13.1 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Height 3.96 m (13 ft) 3.96 m (13 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

39
SGT-400
Industrial gas turbine

The SGT-400 is a twin-shaft gas turbine available in two With over 25 years of operating experience, the SGT-400
­different power ratings for both power generation and is proven in both offshore and onshore applications.
mechanical drive applications. Over 300 units have been sold with approximately 3 million
The twin-shaft arrangement allows for commonality of hours operating experience.
parts in mixed-duty installations.
The gas turbine offers the highest efficiency in its power
class, incorporating the latest aerodynamic and combustion
technologies.

References

Municipal utilities, Erlangen,


Germany
Combined cycle cogeneration
Customer: Erlanger Stadtwerke
Scope: 1 x SGT-400 gas turbine and
1 x SST-300 steam turbine

Bulwer Island, Brisbane,


Australia
Combined cycle power generation
Customer: Alstrom
Scope: 2 × SGT-400 gas turbines

The SGT-400 is available as a factory-assembled package

40
Power generation: 12.9/14.3 MW(e)
Mechanical drive: 13.4/14.9 MW
„„ Latest aerodynamic and combustion
technology
„„ Suitable for all climates, onshore
and offshore
„„ High power-to-weight ratio

Twin-shaft design for both power generation and mechanical drive applications Compact power generation package design

Simple cycle power generation Mechanical drive applications

13 MW version 15 MW version 13 MW version 15 MW version

Power output 12.9 MW(e) 14.3 MW(e) 13.4 MW 14.9 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz 50/60 Hz

Gross efficiency 34.8% 35.4% 36.2% 36.8%

Heat rate 10,355 kJ/kWh 10,178 kJ/kWh 9,943 kJ/kWh 9,774 kJ/kWh

Turbine speed 9,500 rpm 9,500 rpm 9,500 rpm 9,500 rpm

Pressure ratio 16.8 : 1 18.9 : 1 16.8 : 1 18.9 : 1

Exhaust gas flow 39.4 kg/s 44.3 kg/s 39.4 kg/s 44.0 kg/s

Exhaust temperature 555 °C (1,031 °F) 540 °C (1,004 °F) 555 °C (1,031 °F) 540 °C (1,004 °F)

NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 83,824 kg (184,800 lb) 40,142 kg (88,500 lb)

Length 14.0 m (46 ft) 7.3 m (24 ft)

Width 3.1 m (10 ft) 3.1 m (10 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Height 4.3 m (14 ft) 4.3 m (14 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

41
SGT-300
Industrial gas turbine

The SGT-300 industrial gas turbine has a rugged industrial It operates on a wide range of gaseous and liquid fuels.
design that enables high efficiency, reliability, and The compact arrangement, on-site or off-site maintainability,
excellent emissions performance in a broad spectrum of and inherent reliability of the SGT-300 make it an ideal gas
applications for both power generation and mechanical turbine for the demanding oil and gas industry.
drive.
The gas turbine is a proven unit for all electrical power
­generation and cogeneration applications.

References

Over 140 units have been sold,


with more than 4.5 million equivalent
operating hours.

The SGT-300 twin-shaft version is used for mechanical drive

42
Power generation: 7.9 MW(e)
Mechanical drive: 8.2 MW
„„ Low maintenance requirements
„„ Low emissions
„„ Single-shaft version for power
generation, twin-shaft version for
mechancial drive applications

Twin-shaft design – evolutionary ­design focused on reliability SGT-300 gas turbine package design

Simple cycle power generation Mechanical drive applications

Power output 7.9 MW(e) 8.2 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz

Gross efficiency 30.6% 34.6%

Heat rate 11,773 kJ/kWh 10,400 kJ/kWh

Turbine speed 14,010 rpm 11,500 rpm

Pressure ratio 13.7 : 1 13.3 : 1

Exhaust gas flow 30.2 kg/s 29.0 kg/s

Exhaust temperature 542 °C (1,008 °F) 498 °C (924 °F)

NOx emissions ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 59,000 kg (130,073 lb) 32,000 kg (70,548 lb)

Length 11.8 m (38.55 ft) 6.9 m (22.64 ft)

Width 2.9 m (9.35 ft) 2.9 m (9.35 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Height 3.5 m (11.48 ft) 3.9 m (12.76 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

43
SGT-200
Industrial gas turbine

The rugged and compact SGT-200 gas turbine is available The SGT-200 gas turbine combines simple design with
as a single-shaft version for power generation, and as a state-of-the-art technology and is ideally suited for use,
twin-shaft turbine for mechanical drive. for example, as a compressor drive.
The gas turbine operates with various gaseous and liquid More than 430 units have been sold with more than
fuels. It provides high efficiency and an excellent power-to- 30 million equivalent operating hours.
weight ratio and is available as a factory-assembled package.

References

Mining industry, Jingdezhen,


China
Combined heat and power
Customer: Jingdezhen Coking Industry
Group Co. Ltd.
Scope: 2 × SGT-200 1S gas turbines
packaged by ZNGT
Reduced CO2 emissions, lower
operating and production costs

Rapid core engine exchange for minimized downtime

44
Power generation: 6.8 MW(e)
Mechanical drive: 7.7 MW

„„ Robust, reliable design


„„ Flexible fuel capability
„„ Single-shaft and twin-shaft
options available

SGT-200 industrial gas turbine Shop-tested and certified fluid system modules, fully wired
and with onskid controls

Simple cycle power generation Mechanical drive applications

Power output 6.8 MW(e) 7.7 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz

Gross efficiency 31.5% 33%

Heat rate 11,418 kJ/kWh 10,906 kJ/kWh

Turbine speed 11,053 rpm 10,950 rpm

Pressure ratio 12.2 : 1 12.3 : 1

Exhaust gas flow 29.3 kg/s 29.5 kg/s

Exhaust temperature 466 °C (871 °F) 493 °C (919 °F)

NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 15 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 56,245 kg (124,000 lb) 42,637 kg (94,000 lb)

Length 12.5 m (41 ft) 10.4 m (34 ft)

Width 2.4 m (8 ft) 2.4 m (8 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Height 3.4 m (11 ft) 3.4 m (11 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

45
SGT-100
Industrial gas turbine

The SGT-100 industrial gas turbine is a proven unit for The gas turbine has a rugged industrial design that enables
all electrical power generation and mechanical drive high efficiency and excellent emissions performance on a
applications. The compact arrangement, on-site or off-site wide range of gaseous and liquid fuels.
maintainability, and inherent reliability make it an ideal
gas turbine for the demanding oil and gas industry. More than 410 units have been sold with more than ­
24 million operating hours. The lead package has over
120,000 equivalent hours of operation.

References

Girvan, Scotland, UK
Combined heat and power
Customer: William Grant & Sons
distillery
Scope: 1 x SGT-100 gas turbine
­cogeneration package
Able to provide its production process
with steam and electricity, and also to
supply electricity for the region

The SGT-100 combines advanced technology with robust construction

46
Power generation: 5.1/5.4 MW(e)
Mechanical drive: 5.7 MW

„„ Robust and reliable product


„„ Wide range of gaseous and liquid fuels
„„ Single-shaft version for power
generation or twin-shaft version for
mechanical drive applications

Robust, reliable, maintainable single-shaft version for Common modular package design for Common modular package design for
power generation applications power generation ­mechanical drive applications

Simple cycle power generation Mechanical drive applications

5.1 MW version 5.4 MW version

Power output 5.1 MW(e) 5.4 MW(e) 5.7 MW

Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz 50/60 Hz

Gross efficiency 30.2% 31.0% 32.9%

Heat rate 11,914 kJ/kWh 11,613 kJ/kWh 10,948 kJ/kWh

Turbine speed 17,384 rpm 17,384 rpm 13,000 rpm

Pressure ratio 14.0 : 1 15.6 : 1 14.9 : 1

Exhaust gas flow 19.5 kg/s 20.6 kg/s 19.7 kg/s

Exhaust temperature 545 °C (1,013 °F) 531 °C (988 °F) 543 °C (1,009 °F)

NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE) ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package Mechanical drive package

Approx. weight 61,325 kg (135,198 lb) 47,227 kg (104,117 lb)

Length 11.0 m (36.09 ft) 6.1 m (20.01 ft)

Width 2.9 m (9.35 ft) 2.9 m (9.35 ft)


Note: Dimensions exclude inlet filter housing and exhaust stack.
Height 3.6 m (11.81 ft) 3.6 m (11.81 ft) For power generation, AC generator is included. For mechanical drive,
driven equipment is excluded.

47
Aeroderivative
gas turbines
Originally developed for use in aviation, aeroderivative
gas turbines are flexible, ­compact, and lightweight
designs that are ideally suited for power generation
and mechanical drives in the oil and gas industry.
Their high efficiency and fast start capabilities mean
that aeroderivative gas turbines also ­perform well in
decentralized power generation applications.
With a fleet of 2,500 installed units, ­millions of
operation hours in different environments have been
generated in ­numerous reference projects.

Industrial Trent 60............................................................................50

Industrial RB211...............................................................................52

Industrial 501...................................................................................54
Industrial Trent 60
Aeroderivative gas turbine

Designed for industrial use in power generation and speed conditions. It is available with Wet Low Emission
mechanical drive applications, the Industrial Trent 60 has (WLE) and DLE combustion systems.
established a new benchmark for power output, fuel
eco­nomy, and cost savings. The Industrial Trent 60 is proven in many different
environments including arctic, desert, tropical, and coastal
The gas turbine is highly flexible, offering high power and in different applications ranging from peaking to base load,
efficiency with minimal drop-off at part-load and reduced simple cycle, combined cycle, and mechanical drive.

References

Bayonne, New Jersey, USA


Gas-fired power plant
Customer: Hess and ArcLight JV
Scope: 8 × Industrial Trent 60 WLE
ISI units

Dolphin Gas Project, Qatar


Customer: Dolphin Energy Limited
Scope: 9 × Industrial Trent 60 gas
­turbines and 9 × Dresser-Rand
DATUM centrifugal compressors

Three Industrial Trent 60 units for power generation

50
Power generation: 53.1 – 66.0 MW(e)
Mechanical drive: 54.2 – 61.8 MW
„„ Most powerful gas turbine in its class
„„ Flexible with high cyclic life,
fast starts
„„ Modular package design for quick
in­stallation and maintenance

The Industrial Trent 60 can cold-start to full power in under 10 minutes Industrial Trent 60 package for power generation
and also has high cyclic life

Simple cycle power generation Physical dimensions

50 Hz DLE 50 Hz DLE 60 Hz DLE 60 Hz DLE 50 Hz WLE 60 Hz WLE Power generation Mechanical drive
with ISI with ISI with ISI with ISI package package

Power output 53.1 MW(e) 63.5 MW(e) 54.0 MW(e) 61.8 MW(e) 66.0 MW(e) 65.7 MW(e) Approx. 208,000 kg 105,000 kg
weight (458,561 lb) (231,485 lb)
Fuel Natural gas only; other fuels on request Natural gas, liquid fuel, dual fuel;
other fuels on request Length 29.6 m (97 ft) 12.0 m (39.4 ft)

Frequency 50 Hz 50 Hz 60 Hz 60 Hz 50 Hz 60 Hz Width 4.6 m (15 ft) 4.7 m (15.4 ft)

Gross efficiency 42.4% 43.2% 42.5% 43.4% 41.5% 41.1% Height 18.9 m (62 ft) 5.0 m (16.4 ft)

Heat rate 8,488 kJ/kWh 8,322 kJ/kWh 8,465 kJ/kWh 8,300 kJ/kWh 8,669 kJ/kWh 8,760 kJ/kWh

Turbine speed 3,000 rpm 3,000 rpm 3,600 rpm 3,600 rpm 3,000 rpm 3,600 rpm

Pressure ratio 33.3 : 1 37.9 : 1 33.6 : 1 36.2 : 1 39.0 : 1 38.0 : 1

Exhaust gas flow 155 kg/s 177 kg/s 158 kg/s 168 kg/s 180 kg/s 172 kg/s

Exhaust temperature 433 °C (811 °F) 416 °C (781 °F) 431 °C (808 °F) 421 °C (790 °F) 416 °C (781 °F) 426 °C (799 °F)

NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with WLE and DLE)

Combined cycle power generation

DLE 50 Hz DLE 50 Hz WLE 50 Hz DLE 60 Hz DLE 60 Hz WLE 60 Hz


with ISI with ISI with ISI with ISI

Net power output 65.3 MW(e) 77.7 MW(e) 82.9 MW(e) 66.4 MW(e) 77.5 MW(e) 80.3 MW(e)
Note: Industrial Trent 60 WLE – water injected. ISI – Inlet Spray
Net plant efficiency 53.6% 53.4% 51.2% 53.5% 53.5% 50.7% Intercooling (wet compression water to the compressor).
All combined cycle performance is based on 2 pressure, no reheat.
Net heat rate 6,718 kJ/kWh 6,736 kJ/kWh 7,022 kJ/kWh 6,725 kJ/kWh 6,727 kJ/kWh 7,093 kJ/kWh For power generation, AC generator is included, dimensions include inlet
filter housing, exclude exhaust stack. For mechanical drive, driven equip-
Pressure/reheat Dual/No Dual/No Dual/No Dual/No Dual/No Dual/No ment is excluded, dimensions exclude inlet filter housing and exhaust
stack.

51
Industrial RB211
Aeroderivative gas turbine

With class-leading reliability and availability, the Industrial downtime and cost. Both conventional and DLE combustion
RB211 is a proven, dependable choice in power generation systems are available, including dual fuel capability.
and mechanical drive applications. It is qualified to meet
the stringent standards of the oil and gas industry in both In its 40-year evolution, the Industrial RB211 has
onshore and offshore service. accumulated over 36 million equivalent operating hours,
with over 750 units sold.
The aeroderivative gas generator is highly tolerant of
transient excursions and challenging mission cycles, and
can be easily exchanged at site, reducing maintenance

References

Lula (Tupi) and Guará


­oilfields, offshore Brazil
Power generation in eight offshore
oil and gas FPSO vessels
Customer: Petrobras
Scope: 32 × Industrial RB211-GT62
generating sets

West East Pipeline, China


Gas pipeline compression station
Customer: Petro China
Scope: 30 × Industrial RB211 gas
­turbines driving centrifugal pipeline
compressors

Two Industrial RB211 packages on an FPSO vessel

52
Power generation: 27.2 – 32.5 MW(e)
Mechanical drive: 27.9 – 33.8 MW

„„ Proven track record in the O&G market


„„ Several variants to meet different
power needs
„„ Lightweight, compact, modular package
design to maximize power density

The Industrial RB211 is a two-spool gas generator aerodynamically Modular package design to meet specifications of a wide range of
coupled to a free power turbine applications

Simple cycle power generation Physical dimensions

G62 DLE GT62 DLE GT61 DLE GT30 50Hz GT30 60Hz Power generation Mechanical drive
package package
Power output 27.2 MW(e) 29.8 MW(e) 32.1 MW(e) 32.5 MW(e) 31.5 MW(e)
Approx. 150,000 kg 99,000 kg
Fuel Natural gas, liquid fuel, dual fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load weight (330,693 lb) (218,257 lb)
Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50 Hz 60 Hz Length 16.0 m (52.49 ft) 9.2 m (30.2 ft)
Gross efficiency 36.4% 37.5% 39.3% 37.7% 36.4% Width 3.3 m (10.83 ft) 4 m (13.1 ft)
Heat rate 9,904 kJ / kWh 9,589 kJ / kWh 9,159 kJ / kWh 9,549 kJ / kWh 9,901 kJ / kWh Height 5.4 m (17.72 ft) 5 m (16.4 ft)
Turbine speed 4,800 rpm 4,800 rpm 4,850 rpm 3,600 rpm 3,000 rpm

Pressure ratio 20.6 : 1 21.7 : 1 21.6 : 1 22.7 : 1 22.9 : 1

Exhaust gas flow 91.0 kg/s 95.0 kg/s 94.0 kg/s 98.5 kg/s 99.8 kg/s

Exhaust temperature 501 °C (934 °F) 503 °C (937 °F) 510 °C (950 °F) 508 °C (946 °F) 512 °C (953 °F)

NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE)

Combined cycle power generation

G62 GT62 DLE GT61 DLE

Net power output 37.7 MW(e) 39.8 MW(e) 42.6 MW(e)

Net plant efficiency 50.2% 51.4% 52.8%


Note: All combined cycle is based on 2 pressure, no reheat.
Net heat rate 7,175 kJ/kWh 7,005 kJ/kWh 6,820 kJ/kWh For power generation, AC generator is included, dimensions exclude
inlet filter housing and exhaust stack.
Pressure/reheat Dual/No Dual/No Dual/No For mechanical drive, driven equipment is excluded, dimensions
exclude inlet filter housing and exhaust stack.

53
Industrial 501
Aeroderivative gas turbine

Based on proven aeroderivative design, the Industrial 501 fuel, steam, and water injection. DLE technology is also
delivers high efficiency and outstanding reliability for available.
power generation applications like cogeneration, offshore
platforms, and emergency power. The gas turbine offers The Industrial 501 has accumulated over 110 million
rugged, easy-to-maintain performance due to features such hours of operation with more than 500 customers in
as auxiliary equipment. 53 countries.

The gas turbine engine is designed to operate on a wide


variety of fuels. The fuel system operations include dual

References

Grampian, Scotland
Combined heat and power plant
Customer: National Health Service,
Foresterhill Health Campus
Scope: 1 x Industrial 501-K gas turbine

Power station at Mitchelstown, Ireland

54
Power generation: 3.9 – 6.4 MW(e)

„„ More than 1,600 gas turbines supplied


„„ Full power available within 60 seconds
„„ High electrical and cycle efficiency

Industrial 501 on a test stand at Siemens facility in Mount Power Generation with the Industrial 501
­Vernon, Ohio, USA

Simple cycle power generation

Industrial 501-KB5S Industrial 501-KB7S Industrial 501-KH5

Power output 3.9 MW(e) 5.2 MW(e) 6.4 MW(e)

Fuel Natural gas, liquid fuel, duel fuel; other fuels on request; automatic changeover from primary to secondary fuel at any load

Frequency 50/60 Hz 50 / 60 Hz 50/60 Hz

Gross efficiency 29.0% 31.5% 40.1%

Heat rate 12,393 kJ/kWh 11,445 kJ/kWh 8,971 kJ/kWh

Turbine speed 14,200 rpm 14,600 rpm 14,600 rpm

Pressure ratio 10.3 : 1 13.9 : 1 12.5 : 1

Exhaust gas flow 15.4 kg/s 21.1 kg/s 18.4 kg/s

Exhaust temperature 560 °C (1,040 °F) 498 °C (928 °F) 530 °C (986 °F)

NOx emissions ≤ 25 ppmvd at 15% O2 on fuel gas (with DLE)

Physical dimensions

Power generation package

Approx. weight 35,000 kg (85,980 lb)

Length 9 m (29.5 ft)

Width 2.7 m (8.9 ft)


Note: Industrial 501-KH5 with case steam injection (2.73 kg/s)
Height 3.1 m (10.2 ft) Dimensions exclude inlet filter housing and exhaust stack.
For power generation, AC generator is included.

55
Heavy-duty
gas turbines

Aeroderivative
gas turbines

Industrial
gas turbines
References

Siemens gas turbines are operating in more


than 60 countries.
We provide proven technology with more
than 6,750 installed heavy-duty, industrial,
and aeroderivative gas turbines.
Performance data overview
Mechanical drive applications (metric units)

Power output Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature

SGT-750 39.3 MW 41.5% 8,685 kJ / kWh 6,100 rpm 23.8 : 1 113.8 kg/s 458° C

SGT-700 33.7 MW 38.2% 9,424 kJ / kWh 6,500 rpm 18.7 : 1 95.0 kg/s 533° C

SGT-600 25.3 MW 34.6% 10,390 kJ / kWh 7,700 rpm 14.0 : 1 81.3 kg/s 543° C

SGT-500 19.3 MW 34.5% 10,530 kJ / kWh 3,450 rpm 13.0 : 1 97.9 kg/s 369° C

SGT-400 (15 MW) 14.9 MW 36.8% 9,774 kJ / kWh 9,500 rpm 18.9 : 1 44.0 kg/s 540° C

SGT-400 (13 MW) 13.4 MW 36.2% 9,943 kJ / kWh 9,500 rpm 16.8 : 1 39.4 kg/s 555° C

SGT-300 8.2 MW 34.6% 10,400 kJ / kWh 11,500 rpm 13.3 : 1 29.0 kg/s 498° C

SGT-200 7.7 MW 33.0% 10,906 kJ / kWh 10,950 rpm 12.3 : 1 29.5 kg/s 493° C

SGT-100 5.7 MW 32.9% 10,948 kJ / kWh 13,000 rpm 14.9 : 1 19.7 kg/s 543° C

Industrial Trent 60 DLE 54.2 MW 43.6% 8,256 kJ / kWh 3,400 rpm 34.3 : 1 154.4 kg/s 440° C

Industrial Trent 60 WLE 61.8 MW 41.9% 8,592 kJ / kWh 3,400 rpm 36.1 : 1 164.2 kg/s 422° C

Industrial RB211 G62 DLE 27.9 MW 37.3% 9,649 kJ / kWh 4,800 rpm 20.6 : 1 91.3 kg/s 501° C

Industrial RB211 G62 Non-DLE 29.1 MW 37.8% 9,542 kJ / kWh 4,800 rpm 21.3 : 1 93.4 kg/s 500° C

Industrial RB211 GT62 DLE 30.6 MW 38.6% 9,342 kJ / kWh 4,800 rpm 21.7 : 1 95.4 kg/s 503° C

Industrial RB211 GT62 Non-DLE 30.9 MW 38.6% 9,338 kJ / kWh 4,800 rpm 22.0 : 1 96.1 kg/s 501° C

Industrial RB211 GT61 DLE 33.0 MW 40.4% 8,923 kJ / kWh 4,850 rpm 21.6 : 1 93.8 kg/s 510° C

Industrial RB211 GT61 Non-DLE 33.8 MW 40.4% 8,913 kJ / kWh 4,850 rpm 22.1 : 1 95.0 kg/s 510° C

58

58
Mechanical drive applications (imperial units)

Power output Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature

SGT-750 39.3 MW 41.5% 8,232 Btu/kWh 6,100 rpm 23.8 : 1 250.9 lb/s 857° F

SGT-700 33.7 MW 38.2% 8,932 Btu/kWh 6,500 rpm 18.7 : 1 209.0 lb/s 991° F

SGT-600 25.3 MW 34.6% 9,848 Btu/kWh 7,700 rpm 14.0 : 1 179.0 lb/s 1,009° F

SGT-500 19.3 MW 34.5% 9,981 Btu/kWh 3,450 rpm 13.0 : 1 215.9 lb/s 697° F

SGT-400 (15 MW) 14.9 MW 36.8% 9,264 Btu/kWh 9,500 rpm 18.9 : 1 97.7 lb/s 1,004° F

SGT-400 (13 MW) 13.4 MW 36.2% 9,424 Btu/kWh 9,500 rpm 16.8 : 1 86.8 lb/s 1,031° F

SGT-300 8.2 MW 34.6% 9,857 Btu/kWh 11,500 rpm 13.3 : 1 63.9 lb/s 924° F

SGT-200 7.7 MW 33.0% 10,337 Btu/kWh 10,950 rpm 12.3 : 1 65.0 lb/s 919° F

SGT-100 5.7 MW 32.9% 10,377 Btu/kWh 13,000 rpm 14.9 : 1 43.4 lb/s 1,009° F

Industrial Trent 60 DLE 54.2 MW 43.6% 7,825 Btu/kWh 3,400 rpm 34.3 : 1 340.4 lb/s 824° F

Industrial Trent 60 WLE 61.8 MW 41.9% 8,144 Btu/kWh 3,400 rpm 36.1 : 1 362.0 lb/s 792° F

Industrial RB211 G62 DLE 27.9 MW 37.3% 9,145 Btu/kWh 4,800 rpm 20.6 : 1 201.3 lb/s 934° F

Industrial RB211 G62 Non-DLE 29.1 MW 37.8% 9,044 Btu/kWh 4,800 rpm 21.3 : 1 205.9 lb/s 932° F

Industrial RB211 GT62 DLE 30.6 MW 38.6% 8,855 Btu/kWh 4,800 rpm 21.7 : 1 210.3 lb/s 937° F

Industrial RB211 GT62 Non-DLE 30.9 MW 38.6% 8,851 Btu/kWh 4,800 rpm 22.0 : 1 211.9 lb/s 934° F

Industrial RB211 GT61 DLE 33.0 MW 40.4% 8,457 Btu/kWh 4,850 rpm 21.6 : 1 206.8 lb/s 950° F

Industrial RB211 GT61 Non-DLE 33.8 MW 40.4% 8,448 Btu/kWh 4,850 rpm 22.1 : 1 209.4 lb/s 950° F

59

59
Simple cycle power generation (metric units)

Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature

SGT5-8000H 400 MW 50 Hz 40.0% 8,999 kJ/kWh 3,000 rpm 19.2 : 1 869.0 kg/s 627° C

SGT6-8000H 296 MW 60 Hz 40.0% 8,999 kJ/kWh 3,600 rpm 19.5 : 1 640.0 kg/s 630° C

SGT5-4000F 307 MW 50 Hz 40.0% 9,001 kJ/kWh 3,000 rpm 18.8 : 1 723.0 kg/s 579° C

SGT6-5000F 242 MW 60 Hz 39.0% 9,230 kJ/kWh 3,600 rpm 18.9 : 1 576.0 kg/s 600° C

SGT5-2000E 187 MW 50 Hz 36.2% 9,945 kJ/kWh 3,000 rpm 12.1 : 1 558.0 kg/s 536° C

SGT6-2000E 116 MW 60 Hz 34.3% 10,496 kJ/kWh 3,600 rpm 12.1 : 1 367.0 kg/s 537° C

SGT-800 (53.0 MW) 53.0 MW(e) 50/60 Hz 39.0% 9,231 kJ/kWh 6,608 rpm 21.4 : 1 137.2 kg/s 551 °C

SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 9,389 kJ/kWh 6,608 rpm 21.0 : 1 134.2 kg/s 553 °C

SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,547 kJ/kWh 6,608 rpm 20.1 : 1 132.8 kg/s 541° C

SGT-750 38.1 MW(e) 50/60 Hz 40.2% 8,953 kJ/kWh 6,100 rpm 23.8 : 1 113.8 kg/s 458° C

SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,675 kJ/kWh 6,500 rpm 18.7 : 1 95.0 kg/s 533° C

SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,720 kJ/kWh 7,700 rpm 14.0 : 1 81.3 kg/s 543° C

SGT-500 19.1 MW(e) 50/60 Hz 33.8% 10,690 kJ/kWh 3,600 rpm 13.0 : 1 97.9 kg/s 369° C

SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 10.178 kJ/kWh 9,500 rpm 18.9 : 1 44.3 kg/s 540° C

SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 10.355 kJ/kWh 9,500 rpm 16.8 : 1 39.4 kg/s 555° C

SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,773 kJ/kWh 14,010 rpm 13.7 : 1 30.2 kg/s 542° C

SGT-200 6.8 MW(e) 50/60 Hz 31.5% 11,418 kJ/kWh 11,053 rpm 12.2 : 1 29.3 kg/s 466° C

SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,613 kJ/kWh 17,384 rpm 15.6 : 1 20.6 kg/s 531° C

SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,914 kJ/kWh 17,384 rpm 14.0 : 1 19.5 kg/s 545° C

Industrial Trent 60 DLE 53.1 MW(e) 50 Hz 42.4% 8,488 kJ/kWh 3,000 rpm 33.3 : 1 155.0 kg/s 433° C

Industrial Trent 60 DLE with ISI 63.5 MW(e) 50 Hz 43.2% 8,322 kJ/kWh 3,000 rpm 37.9 : 1 177.0 kg/s 416° C

Industrial Trent 60 DLE 54.0 MW(e) 60 Hz 42.5% 8,465 kJ/kWh 3,600 rpm 33.6 : 1 158.0 kg/s 431° C

Industrial Trent 60 DLE with ISI 61.8 MW(e) 60 Hz 43.4% 8,300 kJ/kWh 3,600 rpm 36.2 : 1 168.0 kg/s 421° C

Industrial Trent 60 WLE with ISI 66.0 MW(e) 50 Hz 41.5% 8,669 kJ/kWh 3,000 rpm 39.0 : 1 180.0 kg/s 416° C

Industrial Trent 60 WLE with ISI 65.7 MW(e) 60 Hz 41.1% 8,760 kJ/kWh 3,600 rpm 38.0 : 1 172.0 kg/s 426° C

Industrial RB211 G62 DLE 27.2 MW(e) 50/60 Hz 36.4% 9,904 kJ/kWh 4,800 rpm 20.6 : 1 91.0 kg/s 501° C

Industrial RB211 GT62 DLE 29.8 MW(e) 50/60 Hz 37.5% 9,589 kJ/kWh 4,800 rpm 21.7 : 1 95.0 kg/s 503° C
60
Industrial RB211 GT61 DLE 32.1 MW(e) 50/60 Hz 39.3% 9,159 kJ/kWh 4,850 rpm 21.6 : 1 94.0 kg/s 510° C

Industrial RB211 GT30 50 Hz 32.5 MW(e) 50 Hz 37.7% 9,549 kJ/kWh 3,000 rpm 22.7 : 1 98.5 kg/s 508° C

Industrial RB211 GT30 60 Hz 31.5 MW(e) 60 Hz 36.4% 9,901 kJ/kWh 3,600 rpm 22.9 : 1 99.8 kg/s 512° C

Industrial 501 (6.4 MW) 6.4 MW(e) 50/60 Hz 40.1% 8,971 kJ/kWh 14,600 rpm 12.5 : 1 18.4 kg/s 530 °C

Industrial 501 (5.2 MW) 5.2 MW(e) 50/60 Hz 31.5% 11,445 kJ/kWh 14,600 rpm 13.9 : 1 21.1 kg/s 498 °C

Industrial 501 (3.9 MW) 3.9 MW(e) 50/60 Hz 29.0% 12,393 kJ/kWh 14,200 rpm 10.3 : 1 15.4 kg/s 560° C

60
Simple cycle power generation (imperial units)

Power output Frequency Gross efficiency Heat rate Turbine speed Pressure ratio Exhaust mass flow Exhaust temperature

SGT5-8000H 400 MW 50 Hz 40.0% 8,530 Btu/kWh 3,000 rpm 19.2 : 1 1,915.0 lb/s 1,161° F

SGT6-8000H 296 MW 60 Hz 40.0% 8,530 Btu/kWh 3,600 rpm 19.5 : 1 1,410.0 lb/s 1,166° F

SGT5-4000F 307 MW 50 Hz 40.0% 8,532 Btu/kWh 3,000 rpm 18.8 : 1 1,595.0 lb/s 1,074° F

SGT6-5000F 242 MW 60 Hz 39.0% 8,748 Btu/kWh 3,600 rpm 18.9 : 1 1,270.0 lb/s 1,113° F

SGT5-2000E 187 MW 50 Hz 36.2% 9,427 Btu/kWh 3,000 rpm 12.1 : 1 1,230.0 lb/s 997° F

SGT6-2000E 116 MW 60 Hz 34.3% 9,949 Btu/kWh 3,600 rpm 12.1 : 1 809.0 lb/s 999° F

SGT-800 (53.0 MW) 53.0 MW(e) 50/60 Hz 39.0% 8,749 Btu/kWh 6,608 rpm 21.4 : 1 302.5 lb/s 1,024° F

SGT-800 (50.5 MW) 50.5 MW(e) 50/60 Hz 38.3% 8,899 Btu/kWh 6,608 rpm 21.0 : 1 295.8 lb/s 1,027° F

SGT-800 (47.5 MW) 47.5 MW(e) 50/60 Hz 37.7% 9,048 Btu/kWh 6,608 rpm 20.1 : 1 292.8 lb/s 1,007° F

SGT-750 38.1 MW(e) 50/60 Hz 40.2% 8,486 Btu/kWh 6,100 rpm 23.8 : 1 250.9 lb/s 856.5° F

SGT-700 32.8 MW(e) 50/60 Hz 37.2% 9,170 Btu/kWh 6,500 rpm 18.7 : 1 209.0 lb/s 991° F

SGT-600 24.5 MW(e) 50/60 Hz 33.6% 10,161 Btu/kWh 7,700 rpm 14.0 : 1 179.0 lb/s 1,009° F

SGT-500 19.1 MW(e) 50/60 Hz 33.8% 10,132 Btu/kWh 3,600 rpm 13.0 : 1 215.9 lb/s 697° F

SGT-400 (15 MW) 14.3 MW(e) 50/60 Hz 35.4% 9,647 Btu/kWh 9,500 rpm 18.9 : 1 97.7 lb/s 1,004° F

SGT-400 (13 MW) 12.9 MW(e) 50/60 Hz 34.8% 9,815 Btu/kWh 9,500 rpm 16.8 : 1 86.8 lb/s 1,031° F

SGT-300 7.9 MW(e) 50/60 Hz 30.6% 11,158 Btu/kWh 14,010 rpm 13.7 : 1 66.6 lb/s 1,008° F

SGT-200 6.8 MW(e) 50/60 Hz 31.5% 10,822 Btu/kWh 11,053 rpm 12.2 : 1 64.5 lb/s 871° F

SGT-100 (5.4 MW) 5.4 MW(e) 50/60 Hz 31.0% 11,007 Btu/kWh 17,384 rpm 15.6 : 1 45.4 lb/s 988° F

SGT-100 (5.1 MW) 5.1 MW(e) 50/60 Hz 30.2% 11,292 Btu/kWh 17,384 rpm 14.0 : 1 43.1 lb/s 1,013° F

Industrial Trent 60 DLE 53.1 MW(e) 50 Hz 42.4% 8,045 Btu/kWh 3,000 rpm 33.3 : 1 342.0 lb/s 811° F

Industrial Trent 60 DLE with ISI 63.5 MW(e) 50 Hz 43.2% 7,888 Btu/kWh 3,000 rpm 37.9 : 1 390.0 lb/s 781° F

Industrial Trent 60 DLE 54.0 MW(e) 60 Hz 42.5% 8,023 Btu/kWh 3,600 rpm 33.6 : 1 348.0 lb/s 808° F

Industrial Trent 60 DLE with ISI 61.8 MW(e) 60 Hz 43.4% 7,867 Btu/kWh 3,600 rpm 36.2 : 1 370.0 lb/s 790° F

Industrial Trent 60 WLE with ISI 66.0 MW(e) 50 Hz 41.5% 8,217 Btu/kWh 3,000 rpm 39.0 : 1 397.0 lb/s 781° F

Industrial Trent 60 WLE with ISI 65.7 MW(e) 60 Hz 41.1% 8,303 Btu/kWh 3,600 rpm 38.0 : 1 379.0 lb/s 799° F

Industrial RB211 G62 DLE 27.2 MW(e) 50/60 Hz 36.4% 9,387 Btu/kWh 4,800 rpm 20.6 : 1 200.6 lb/s 934° F

Industrial RB211 GT62 DLE 29.8 MW(e) 50/60 Hz 37.5% 9,089 Btu/kWh 4,800 rpm 21.7 : 1 209.4 lb/s 937° F
61
Industrial RB211 GT61 DLE 32.1 MW(e) 50/60 Hz 39.3% 8,681 Btu/kWh 4,850 rpm 21.6 : 1 207.2 lb/s 950° F

Industrial RB211 GT30 50 Hz 32.5 MW(e) 50 Hz 37.7% 9,051 Btu/kWh 3,000 rpm 22.7 : 1 217.2 lb/s 946° F

Industrial RB211 GT30 60 Hz 31.5 MW(e) 60 Hz 36.4% 9,384 Btu/kWh 3,600 rpm 22.9 : 1 220.0 lb/s 953° F

Industrial 501 (6.4 MW) 6.4 MW(e) 50/60 Hz 40.1% 8,503 Btu/kWh 14,600 rpm 12.5 : 1 40.6 lb/s 986° F

Industrial 501 (5.2 MW) 5.2 MW(e) 50/60 Hz 31.5% 10,848 Btu/kWh 14,600 rpm 13.9 : 1 46.5 lb/s 928° F

Industrial 501 (3.9 MW) 3.9 MW(e) 50/60 Hz 29.0% 11,746 Btu/kWh 14,200 rpm 10.3 : 1 34.0 lb/s 1,040° F

61
Published by
Siemens Energy, Inc.

Power and Gas Division


4400 Alafaya Trail
Orlando, FL 32826-2399, USA

For more information, please contact


our Customer Support Center.
Phone: +49 180 524 70 00
Fax: +49 180 524 24 71
(Charges depending on provider)
E–mail: support.energy@siemens.com

Article-No. PGDG-B10006-00-4AUS
Printed in Germany
Dispo 34806 BR 11152.0

Subject to changes and errors. The information given in


this document only contains general descriptions and/or
performance features which may not always specifically
reflect those described, or which may undergo modification
in the course of further development of the products. The
requested performance features are binding only when
they are expressly agreed upon in the concluded contract.

S-ar putea să vă placă și