Documente Academic
Documente Profesional
Documente Cultură
Revision: R1
TeamWork Glass Solutions Pvt Ltd,Bangalore proposes to install semi unitised glazing using extruded
aluminum profile system for Cochin Airport Project at Calicut. This structural design report is
prepared to evaluate structural performance of the structural glazing semi unitised system and its
components and to ensure the total stability of the entire system using the provisions of cited
references codes and generally accepted industry practice.
The following is a summary of the properties of materials, structural performance and serviceability
requirements for the Aluminum and Glass system.
Grade A4-70
0.2% Proof stress = 450Mpa
Tensile strength (As per SCI P291 section 5.2.2) = 700Mpa
Shear strength = 311Mpa
Tensile strength (As per BS 8118-1:1991 section 6.4.1) = 450Mpa
Limiting stress = 540Mpa
Structural Analysis is done utilizing profiles of extruded Aluminum sections and 6mm+1.52mm+6mm thick
Laminated glass for panel of 1x5.95 sqm and a Design wind pressure of 1.5 Kpa.
This load is considered based on the specification document provided. Dead load of the ACP panel
and the frame is considered as a self-load
The maximum permissible deflection of the Aluminum Vertical members is taken as Span /175 or 19 mm
for Transom L/300 or 3mm mm and the vertical dead load deflection for transom is span/300 or 3mm
whichever is less as per tender document, and the permissible glass deflection is taken
as Span/90 or 19mm for SGU and for DGU span/90 or 19 mm, As per specification document.
Glass panels are designed to resist the applicable wind forces and to ensure deflection within
tolerable limits. Glass Panels are designed assuming simply supported on all four edges.
Vertical members are designed to resist entire wind load on the module and are analyzed as a
Continuous supported beam of overall length of 5495 mm. The loading on the vertical member is taken as
rectangular loading & on the Horizontal member as Triangular loading.
Airport Project
Calicult Date: 11 Nov 2017
Double Glazed Insulating Glass (IG) with Monolithic Glass lites of equal (symmetric) or Different (Asymmetric)
Glass type and thickeness Simply Supported Continuously along Four Sides
Design Load (q): 1.5 kN/sq.m SAFE for short Duration load
Deflection: 7 mm
(if the value falls outside the chart then proceed to alternate proceduture to calculate deflection as
mentioned below.)
2
Max.Glass Deflection (w): t * exp (r0 + r1 * x + r2 * x )
r0 = 0.553-3.83(a/b)+1.11(a/b)^2-0.0969(a/b)^3 = -2.99226
r1 = -2.29+5.83(a/b)-2.17(a/b)^2+0.2067(a/b)^3 = 2.251454
r2 = 1.485-1.908(a/b)+0.815(a/b)^2-0.0822(a/b)^3 = 0.180051
x = In{In[q(ab)^2/Et4]} = 1.269413
w = 7.012236 mm
Stability calculations for the structural sealant for the unitized system panel of size 1.0m x 1.475m
The verifications of the sealant are carried out according to the indications in order to verify the minimum
sealant joint thickness and minimum stress in sealant.
Minimum Silicon Bite Reqd = Hmc = 0.5 x Shortspan length in mm X Wind load in Kpa / Sealany Strength in Mpa
Hmc = (0.5X1000X1.5)/138 = 5.43 mm
Seleant bite provided for the glazing is 6 mm, which is > 5.43 mm
Stability calculation for the Following Aluminum member for the structural glazing system.
* Mullion
* Transom
* MS Bracket
* Anchors
Airport Project
Calicult Date: 11 Nov 2017
Fig - 2
Airport Project
Calicult Date: 11 Nov 2017
Actual bending stress in profile = Bending Moment / Provided section modulus = B.M/Zxx
2
= 62.84 N/mm
Actual Bending Stress < Permissible Bending Stress
2
62.84 < 96 N/mm SAFE
The Eulers critical stress for buckling of the member in the direction of the applied bending moment,
2
Pe = *E/(l/r)2
2
= 3.142^2x65500/119.86^2= 45.03 N/mm
Check for combined Bending and Axial Compression: Refer Clause 7.5.2, IS 8147
1.33/85+62.84/96(1-(1.33/45.03) 1
0.690 < 1 SAFE
Fig - 3
Actual Shear Stress in Screw = Resultant Force / no. of shear x no. of screw x Net area = (RF/no. x n x An)
2
= 41.50 N/mm
Actual shear stress in screw < Permissible Shear Stress of Screw (Pss) SAFE
300
55 190 55
125
141
230
85
230
Applied Loads:
Reference for
Loads
Airport Project
Calicut Date: 11 Nov 2017
Steel Design:
Airport Project
Calicut Date: 29 Nov 2017
300
55 190 55
150
100
40
500
230
230
Applied Loads:
Reference for
Loads
Airport Project
Calicut Date: 29 Nov 2017
Steel Design:
Airport Project
Calicut Date: 29 Nov 2017
Details of the top Bracket -1 (Consider 122x61x4.5 mm box to which two ear plates are welded)
e1 = 85 mm
e2 = 35 mm
d2 = 125 mm
t = 8 mm
b= 100 mm
125
85
230
2
Shear Strength of the bolt : Psb = (0.48*Fub) = 336 N/mm
2
Psb = (0.69*Fyb) = 310.5 N/mm
2
Gross area of the bolt Ag = 78.5 mm
2
Shear area of the bolt As = 58.88 mm
Shear Capacity of the Bolt = Min.Psb x As = 18280.6875 N
Actual Shear per bolt = 6109.17 N SAFE
No of Interfaces Ni = 2
2
Allowable Bearing Stress for Aluminum Pb = 139 N/mm
Thickness of Aluminum profile ts = 4 mm
Dia of Bolt hole d0 = 11.5 mm
Bearing Stregth of Connecting part Fb = NiXPbXtsXd0
= 12788 N
> 6109.17 N SAFE
Details of the top Bracket-2 (Consider 122x61x4.5 mm box to which two ear plates are welded)
e1 = 85 mm
e2 = 35 mm
d2 = 125 mm
85 t = 8 mm
230 b= 100 mm
Dead Load = 0 N
Wind Load = 12916 N
Factored Dead load (DL x1.5) = 0 N
Factored Wind load (WL x1.5) = 19374 N
Consider 2 Nos of steel bracket plates of size 100x230x8 thick of length of 100 mm
= 91349.9342 N
Resultant shear on each plate = 9687.00 N SAFE
= 205512.336 N
Maximum Tension On each Plate = 9687 N SAFE
No of Interfaces Ni = 2
2
Allowable Bearing Stress for Aluminum Pb = 139 N/mm
Thickness of Aluminum profile ts = 4 mm
Dia of Bolt hole d0 = 11.5 mm
Bearing Stregth of Connecting part Fb = NiXPbXtsXd0
= 12788 N
> 9687.00 N SAFE
Weld Stress due to Axial force f =P/t*l1 = 0.00 N/mm2 (on extreme face)
Weld Stress in Shear q=(V/t*l2) = 23.06 N/mm2
Combined Stress: (f2+3q2) = 39.95 N/mm2
Permissible stree in wels = fu/ 3* mw = 159 N/mm2 SAFE
Airport Project
Calicut Date: 29 Nov 2017
125 e1 = 75 mm
117
8 4
e2 = 35 mm
50 d2 = 125 mm
t = 8 mm
b= 100 mm
232
Dead Load = 0 N
Wind Load = 3831 N
Factored Dead load (DL x1.5) = 0 N
Factored Wind load (WL x1.5) = 5746.5 N
Consider 2 Nos of steel bracket plates of size 95x125x8 thick of length of 100 mm
= 91349.9342 N
Resultant shear on each plate = 2873.25 N SAFE
= 205512.336 N
Maximum Tension On each Plate = 2873.25 N SAFE
No of Interfaces Ni = 2
2
Allowable Bearing Stress for Aluminum Pb = 139 N/mm
Thickness of Aluminum profile ts = 4 mm
Dia of Bolt hole d0 = 11.5 mm
Bearing Stregth of Connecting part Fb = NiXPbXtsXd0
= 12788 N
> 2873.25 N SAFE
Design Anchors
Following Pages Contains the Design of Anchors for Top and Bottom Brackets
www.hilti.in Profis Anchor 2.7.3
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 15-11-2017
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HSA-R2 M16 hnom3
Effective embedment depth: hef = 120 mm, hnom = 132 mm
Material: A2
Evaluation Service Report: ETA 11/0374
Issued I Valid: 08-08-2016 | -
Proof: Design method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Anchor plate: lx x ly x t = 300 mm x 180 mm x 12 mm; (Recommended plate thickness: not calculated
Profile: Rectangular hollow; (L x W x T) = 122 mm x 61 mm x 5 mm
Base material: uncracked concrete, C30/37, fc,cube = 37.00 N/mm2; h = 200 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 15-11-2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 15-11-2017
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 15-11-2017
E-Mail:
7 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 15-11-2017
E-Mail:
8 Installation data
Anchor plate, steel: - Anchor type and diameter: HSA-R2 M16 hnom3
Profile: Rectangular hollow; 122 x 61 x 5 mm Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 16 mm
Plate thickness (input): 12 mm Hole depth in the base material: 140 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 180 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
150 150
3 4
1 2
55 190 55
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HSA-R2 M16 hnom1
Effective embedment depth: hef = 65 mm, hnom = 77 mm
Material: A2
Evaluation Service Report: ETA 11/0374
Issued I Valid: 08-08-2016 | -
Proof: Design method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Anchor plate: lx x ly x t = 300 mm x 180 mm x 12 mm; (Recommended plate thickness: not calculated
Profile: Rectangular hollow; (L x W x T) = 122 mm x 61 mm x 5 mm
Base material: uncracked concrete, C30/37, fc,cube = 37.00 N/mm2; h = 200 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
7 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
8 Installation data
Anchor plate, steel: - Anchor type and diameter: HSA-R2 M16 hnom1
Profile: Rectangular hollow; 122 x 61 x 5 mm Installation torque: 0.080 kNm
Hole diameter in the fixture: df = 18 mm Hole diameter in the base material: 16 mm
Plate thickness (input): 12 mm Hole depth in the base material: 85 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 140 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
150 150
30
3 4
90
120 x
90
1 2
30
55 190 55
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HSA-R M10 hnom1
Effective embedment depth: hef = 40 mm, hnom = 50 mm
Material: A4
Evaluation Service Report: ETA 11/0374
Issued I Valid: 08-08-2016 | -
Proof: Design method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0 mm (no stand-off); t = 8 mm
Anchor plate: lx x ly x t = 100 mm x 180 mm x 8 mm; (Recommended plate thickness: not calculated
Profile: Double flat bar; (L x W x T) = 100 mm x 50 mm x 2 mm
Base material: uncracked concrete, C30/37, fc,cube = 37.00 N/mm2; h = 200 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
6 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
7 Installation data
Anchor plate, steel: - Anchor type and diameter: HSA-R M10 hnom1
Profile: Double flat bar; 100 x 50 x 2 mm Installation torque: 0.025 kNm
Hole diameter in the fixture: df = 12 mm Hole diameter in the base material: 10 mm
Plate thickness (input): 8 mm Hole depth in the base material: 58 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 100 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
50 50
30
2
90
120
x
90
1
30
50 50
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HSA-R M10 hnom1
Effective embedment depth: hef = 40 mm, hnom = 50 mm
Material: A4
Evaluation Service Report: ETA 11/0374
Issued I Valid: 08-08-2016 | -
Proof: Design method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0 mm (no stand-off); t = 8 mm
Anchor plate: lx x ly x t = 250 mm x 100 mm x 8 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: uncracked concrete, C25/30, fc,cube = 30.00 N/mm2; h = 300 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
6 Warnings
The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility!
Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.7.3
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 29-11-2017
E-Mail:
7 Installation data
Anchor plate, steel: - Anchor type and diameter: HSA-R M10 hnom1
Profile: no profile Installation torque: 0.025 kNm
Hole diameter in the fixture: df = 12 mm Hole diameter in the base material: 10 mm
Plate thickness (input): 8 mm Hole depth in the base material: 58 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 100 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
125 125
50
50
1 2 x
50
50
50 150 50
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan