eq. spaces
Special Case (out of plane) (Use C values for k=0)
Results:
(Note: AISC Alternate Method 2 is not used for P=Pv)
L= 8.000 in. L = vertical weld length
kL = 4.000 in. kL = spacing of vertical welds
aL = 6.000 in. aL = dist. from Pv to C.G.
a= 0.750 a = (aL)/L 2
k= 0.500 k = (kL)/L
C1 = 1.0 C1 = 1.0 for E70XX electrode
C= 0.712 (interpolated from Table XIX, page 4-75)
P= 22.00 kips P = SQRT(Pv^2+Ph^2)
Angle θ = 0.000 deg. θ = 90-(ATAN(Pv/Ph))
Co = N.A. Co = C (from AISC Table XIX, page 4-75)
C(max) = N.A. C(max) = 0.928*(2)
A= N.A. A = C(max)/Co >= 1.0
Ca/Co = N.A. Ca/Co = A/(SINθ+A*COSθ) >= 1.0
Ca = N.A. Ca = (Ca/Co)*Co
D(req'd) = 3.862 1/16's D(req'd) = P/(C*C1*L)
L(req'd) = 7.725 in. L(req'd) = P/(C*C1*D)
Weld is adequate!
D(req'd) = 3.862 <= 4 (1/16's)
L(req'd) = 7.725 <= 8 in.
1 of 1 4/9/2019 1:50 PM