Documente Academic
Documente Profesional
Documente Cultură
.
Wire Reinforcing Institute
“Fabric half buried in the subgrade, has little
value”
“It is impossible to “hook” fabric uniformly to
the desired location after the concrete has been
placed”
Suggested Support Spacing
Control joint
Control joint spacing, L
L/2 Longitudinal
Steel Area, As
IS
Potential crack
Concrete Weight
FLW
As =
2 fs
As = cross-sectional area of steel
F = subgrade friction coefficient
L = distance between joints
W = weight of concrete
fs = reinforcing allowable stress (psi)
ACI 360R – 10
Recommended Control
Joint Spacing for
Unreinforced Concrete
(Less than %As = 0.5%)
ACI 360R - 10
3.2—Slab types
3.2.1 Unreinforced concrete slab
Temperature/
Reinforced for Structural
Shrinkage Crack Width Control
Multifilaments or Monofilaments:
Separate single fibers, round, smooth, straight.
-Nylon
-Polyester
-Polypropylene
Fibrillated:
Joined fibers, grooved angular, 3D
-Polypropylene
Multifilament
Residential Slabs-On-Grade
Thousands of Successful
Residential Applications
Worldwide Since 1982
Monofilament Fibers
Inhibit Plastic Shrinkage and
Settlement Cracking
Fibrillated Polypropylene
Inhibit Early Age Shrinkage Cracking
Reduce Settlement Cracking
Increases Impact Resistance
Increases Shatter Resistance
Reduces Water Migration
Increases Abrasion Resistance
Reduces Rate of Corrosion
Increases Rebar Bond to Concrete
Measurable Residual Strength
Alternate System to Welded Wire Fabric
2 – 4’’ of high strength fiber
reinforced
concrete is placed over prepared,
distressed asphalt.
polymeric fibers.”
Concrete Reinforcement Spectrum
# 3 Rebar 18” OCEW
Temperature/
Reinforced for Structural
Shrinkage Crack Width Control
Provides Factors of Safety: on the basis of the location of the load with respect to the edges
of the slab. “Interior – Free Edge – Corner” Factors of Safety
C 09 Documents:
C 1399, “Test Method for Obtaining Average
Residual-Strength of Fiber Reinforced
Concrete”
Fiber Basics
Load
ASTM C 1399
Average Residual Strength, ARS
N With steel plate
lbs [(A+B+C+D) / 4] x
ARS = -------------------------
b d2
A B C D
Design Program
SFRC
Steel Fibers
Steel Fibers
Restricts Joint Width
Always Positioned
Correctly
”
16
Unprotected
sawn joints armored joint High dosage
of steel fibers
MACROSYNTHETIC & BLENDS
ACI 360R 10: Chapter 11 –
Fiber-Reinforced Concrete Slabs-on-
Ground
2.2 Million
Square Feet
Macro-Micro Syn
Macro Synthetic
Steel-Synthetic
Monofilament
Fibrillated
Steel Fiber
Long-term Performance
Early Age Performance
Crack Prevention Crack Containment
Steel + Synthetic Blend
Steel Fibers
+ Microsynthetic Fibers
= Blended System
ASTM C-1018 Flexural Toughness
(Steel: 20 lbs/yd3, Micro-Fiber: 1.5 lbs/yd3)
20
18 2" Xorex Steel Fibre
16 2" Xorex Steel Fibre + Fibermesh
14
Load (kN)
12
10
8
6
4
2
0
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
Deflection (mm)
Bering Truck Plant
Macro – Micro Blend
The all-synthetic macro
blend
Recognized By ACI
360R-06 Design of
Slabs-on-Ground
Macro & Micro-Synthetic Blend @ 7.5 PCY
Replaced WD-9 WWF Sheets
Composite Metal Decking
Fiber Reinforced
Concrete
Concrete
for the
Future