Sunteți pe pagina 1din 32

FSECU Downloading

FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• The following presentation contains step by step information


detailing how to download the G150 FSECU fault log
• In preparation for this activity perform the following in
accordance with the G150 AMM
• Prepare the aircraft for safe maintenance
• Connect external (ground) power
• Once the FSECU download .txt file has been obtained
(via this download procedure), please email the file to
techops.midcabin.data@gulfstream.com for analysis
assistance
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Equipment / Tools required to complete this task:


• Laptop computer with current EATON FSECU download application
installed. (available via mygulfstream.com link to EATON site)
• RS232 Interface cable (commonly available at Radio Shack (P/N 26-117B)
or equivalent)
• Small blade flat head screwdriver (longer stem as shown)
• Flashlight
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select both L & R Avionics overhead switches to “ON”


• Note: CABIN & GALLEY may be selected “ON” for interior lighting
functionality
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Pull the four FLAPS SLATS overhead circuit breakers shown


FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Locate and remove the FSECU access panel in the LAV closet
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Locate and remove the FSECU 232 com port dust cover by
removing the two small flat head screws
• Note: These fasteners are not captive to the cap, so care must be taken
so that they are not dropped
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Note the FSECU S/N listed on the EATON data plate shown
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Connect the male (shown) RS232 cable end to the FSECU 232 com
port
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Ensure that the EATON download software has not yet been
launched and connect the female (shown) RS232 cable end to the
Laptop 232 com port
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Launch EATON download software by selecting the Icon shown on


the Laptop Desktop
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “View Fault Data”


FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Verify Laptop com port selected matches Com port being utilized on
the Laptop. (most likely com1)
• Select “OK”
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “OK” (as the Flap Slat circuit breakers were pulled earlier
thereby removing FSECU power)
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Press and seat the four FLAPS SLATS overhead circuit breakers
shown
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• EATON software will auto display this next screen


• Enter the FSECU S/N noted earlier and select “OK”
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “R: Read 32767 Faults”


• Note: This download will take several minutes (status screen will
display download progress)
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “Change File Storage Location”


FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Highlight the destination folder on Laptop where FSECU download


is to be saved
• DO NOT enter a file name and simply select “Current Folder”
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “Save Faults To User Defined Folder”


FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Verify .txt download file exists in the Laptop folder destination


selected earlier
• Note: Auto assigned file name should be the FSECU S/N followed by a
date time stamp as shown above where the S/N, in this case, was 484
downloaded December 09, 2009 at 9:29am
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Open the .txt download file to verify content


FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “EXIT”
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select “EXIT”
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Pull the four FLAPS SLATS overhead circuit breakers shown


FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Disconnect the male RS232 cable end from the FSECU 232 com port
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Disconnect the female RS232 cable end from Laptop 232 com port
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Reinstall the FSECU 232 com port dust cover using the two small
flat head screws
• Note: These fasteners are not captive to the cap, so care must be taken
so that they are not dropped
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Press and seat the four FLAPS SLATS overhead circuit breakers
shown
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Select both L & R Avionics overhead switches to “OFF”


• Select CABIN & GALLEY overhead switches to “OFF”
• Disconnect external (ground) Power per AMM
FSECU Downloading Prepared by Lor Izzard and Robert Hadley

• Reminder:
• Please email the downloaded .txt file to
techops.midcabin.data@gulfstream.com for analysis
assistance