Sunteți pe pagina 1din 5

CREATE THE PROJECT

1. FILE>>>NEW (NAME: CASTRO VALLEY) (DESCRIPTION: CASTRO VALLEY URBAN STUDY)


2. DEFAULT UNIT SYSTEM: U.S. CUSTOMARY >>> CREATE
______________________________________________________________________________
3. TOOLS>>>PROGRAM SETTINGS>>>DEFAULTS>>> LOSS: INITIAL AND CONSTANT>>>
TRANSFORM: SNYDER UNIT HYDROGRAPH >>> BASEFLOW: RECESSION >>> ROUTING:
MUSKINGUM >>> LOSS/GAIN: NONE >>> PRECIPITATION: GAGE WEIGHTS >>>
EVAPOTRANSPIRATION: NONE >>> SNOWMELT: NONE >>> OK

INPUT DATA

1. *COMPONENTS>>>TIME-SERIES DATA MANAGER>>>DATA TYPE: PRECIPITATION


GAGES>>>NEW>>>(NAME: FIRE DEPT) (DESCRIPTION:CASTRO VALLEY FIRE
DEPARTMENT)>>>CREATE – CLOSE
2. TIME-SERIES GAGE>>>DATA SOURCE: SINGLE RECORD HEC-DSS
3. TIME-WINDOW>>>START DATE:06JUL2018 >>>START TIME: 03:10>>>END DATE:
06JUL2018>>>END TIME: 09:50>>> TABLE>>> GRAPH
______________________________________________________________________________

4. *COMPONENTS>>>TIME-SERIES DATA MANAGER>>>DATA TYPE: DISCHARGE


GAGES>>>NEW>>>(NAME: OUTLET) (DESCRIPTION:CASTRO VALLEY OUTLET GAGE)>>>CREATE
– CLOSE
5. TIME-SERIES GAGE>>>DATA SOURCE: SINGLE RECORD HEC-DSS
6. TIME-WINDOW>>>START DATE:06JUL2018 >>>START TIME: 03:00>>>END DATE:
06JUL2018>>>END TIME: 13:00>>> TABLE>>> GRAPH
______________________________________________________________________________
7. *COMPONENTS>>>PAIRED DATA MANAGER>>>DATA TYPE: STORAGE-DISCHARGE
FUNCTIONS>>>NEW>>>(NAME: TABLE 1) (DESCRIPTION:REACH-2)>>>CREATE – CLOSE
8. PAIRED DATA>>>DATA SOURCE: MANUAL ENTRY>>>UNITS: AC-FT:CFS>>>TABLE>>>>>
CREATE THE BASIN MODEL

1. *COMPONENTS>>>BASIN MODEL MANAGER>>> NEW (NAME: CASTRO 1) (DESCRIPTION:


EXISTING CONDITIONS)>>>CREATE – CLOSE

CREATE THE ELEMENT NETWORK

2. BASIN MODELS>>>HELP>>>INSTALL SAMPLE PROJECTS>>>CASTRO_VALLEY


3. VIEW>>>BACKGROUND MAPS>>>ADD>>>CASTRO>>>MAPS>>>*.map>>>select

4. SUBBASIN ICONS
5. REACH ELEMENTS
6. JUNCTION ELEMENTS
7. CONNECT ELEMENTS

ENTER ELEMENT DATA

1. PARAMETERS>>>SUBBASIN AREA>>>SHOW ELEMENTS>>>ALL….APPLY

2. PARAMETERS>>>LOSS>>>INITIAL AND CONSTANT>>> SHOW ELEMENTS>>>ALL….APPLY

3. PARAMETERS>>>TRANSFORM>>>SNYDER UNIT>>> SHOW ELEMENTS>>>ALL….APPLY


4. PARAMETERS>>>BASEFLOW>>>RECSESSION>>> SHOW ELEMENTS>>>ALL>>>DPA….APPLY

5. RENAME JUNCTION ELEMENTS>>>EAST BRANCH>>>OUTLET>>>WEST BRANCH


6. REACH-1 (MUSKINGUM TO MODIFIED PULS)
CREATE THE METEOROLOGIC MODEL

1. *COMPONENTS>>>METEOROLOGIC MODEL MANAGER>>> NEW (NAME: GAGE WTS)


(DESCRIPTION: THIESSEN WEIGHTS, 10-MIN DATA)>>>CREATE – CLOSE

2. BASINS TAB>>>YES
3. PRECIPITATION GAGES>>>TOTAL STROM GAGES
46…. SO ON

DEFINE CONTROL SPECIFICATIONS

1. *COMPONENTS>>>CONTROL SPECIFICATIONS MANAGER>>> NEW (NAME: CASTRO 1)


(DESCRIPTION: EXISTING CONDITIONS)>>>CREATE – CLOSE
2. COMPUTE>>>CREATE COMPUTE>>>SIMULATION RUN

S-ar putea să vă placă și