Sunteți pe pagina 1din 7

Appendix I - Acceptance Criteria

1. ASME SECTION I, Paragraph PW-51, ASME SECTION VIII


DIVISION I, ASME B31.1, Paragraph 136.4.5, API 650

TABLE 1-1 - Maximum Discontinuity Size Allowed

ASME Sec. I; ASME Sec. VIII, Div. I, ASME Sec VIII Div. I,
Defect
ASME B31.1(Power Para. UW-51; API 650 Paragraph UW-52
Piping like Power plants)
Crack None None None
Lack Of Fusion None None None
Incomplete None None None
Penetration
Elongated 6.0 mm (¼") for t up to 6.0 mm (¼") for t up to 2/3 t where t is the thickness
Indications 19.0 mm (¾") inclusive; 19.0 mm (¾"); of the weld excluding
1/3t for t from 19.0 mm (¾") 1/3t for t from 19.0 mm (¾") allowed reinforcement
to 57.0 mm (2¼") inclusive; to 57.0 mm (2¼") inclusive;
19 mm (¾") for t over 19 mm (¾") for t over
57 mm (2¼") 57 mm (2¼")
Group Of aggregate length greater aggregate length greater The sum of the longest
Aligned than t in a length of 12t, than t in a length of 12t, dimensions of all such
Indications except when the distance except when the distance indications is < t in a length
between successive between successive of 6t & the longest
indications exceeds 6L indications exceeds 6L indications are separated by
where L is the longest where L is the longest 3L where L is the length of
indication in the group indication in the group the longest indication. The
maximum length of
acceptable indication shall
be 3/4". Any such indication
shorter than 1/4" shall be
acceptable for any plate
thickness.
Porosity & Refer to section 5.2 of this Refer to section 5.2 of this Round indications are not a
Rounded SAEP SAEP factor unless 100%
Indications examination is required.
Tungsten Refer to section 5.2 of this Refer to section 5.2 of this Rounded tungsten inclusions
SAEP. SAEP. are to be evaluated as
rounded indications per UW-
51. Elongated and aligned
tungsten inclusions are
unacceptable.
Root Concavity Unacceptable if the density
is greater than that of the
parent material.
Rounded Indications shall be judged against the standards set forth in ASME Section VIII - Division 1,
Appendix 4.

2. ASME B31.3 (Process Piping like Refineries, Fertilizers and Chemicals)

2.1 The type of weld joints and service conditions shall be considered
to determine the method of NDE required. Table 2-1 is to be used
with all notes and is included with this SAEP for radiographic film
interpretation..

2.2 Porosity - Refer to Table 1.1 of this appendix.


Table 2-2 - Acceptance Criteria for Table 2-1

Symbol Measure Acceptable Value Limits (Note 6)


A Extent of imperfection Zero (no evident imperfection)
B Depth of incomplete penetration  0.8 mm (1/32 in.) and  0.2Tw
Cumulative length of incomplete penetration  38 mm (1.5 in.) in any 150 mm (6 in.) weld length
C Depth of lack of fusion and incomplete  0.2Tw
penetration
Cumulative length of lack of fusion and  38 mm (1.5 in.) in any 150 mm (6 in.) weld length
incomplete penetration [Note (7)]
D Size and distribution of internal porosity See BPV Code, Section VIII, Division I, Appendix 4
E Size and distribution of internal porosity For Tw  6.4 mm (¼ in.), limit is same as D
For Tw > 6.4 mm (¼ in.), limit is 1.5 X D
F Slag inclusion or elongated indication
Individual length  Tw/3
Individual width  2.4 mm (3/32 in.) and  Tw/3
Cumulative length  Tw in any 12Tw weld length
G Slag inclusion or elongated indication
Individual length  2Tw
Individual width  3.2 mm (1/8 in.) and Tw/2
Cumulative length  4Tw in any 150 mm (6 in.) weld length
H Depth of undercut  0.8 mm (1/32 in.) and Tw/4
I Depth of undercut  1.6 mm (1/16 in.) and Tw/4 or 0.8 mm (1/32 in.)
J Surface roughness < 500 min. Ra per ASME B46.1
K Depth of root surface concavity Total joint thickness, incl. weld reinf.,  Tw
L Height of reinforcement or internal protrusion For Tw mm (in.) Height, mm (in.)
[Note (8)] in any plane through the weld shall  6.4 (¼)  1.6 (1/16)
be within limits of the applicable height value in > 6.4 (¼),  12.7 (½)  3.2 (1/8)
the tabulation at right. Weld metal shall merge > 12.7 (½),  25.4 (1)  4.0 (5/32)
smoothly into the component surfaces. > 25.4 (1)  4.8 (3/16)
M Height of reinforcement or internal protrusion Limit is 2L
[Note (8)] as describe in L
** Tungsten Inclusions To be evaluated as rounded indications. Elongated
or aligned tungsten inclusions are unacceptable.
Tw = Nominal wall thickness of the thinner of two components joined by a butt weld.

Notes:
(1) Criteria given are for required examination. More stringent criteria may be specified in the engineering design. See
also paragraphs. 341.5 and 341.5.3 of ASME/ANSI B31.3
(2) Longitudinal groove weld includes straight and spiral seam. Criteria are not intended to apply to welds made in
accordance with a standard listed in Table A-I or Table 326.1 of ASME B31.1.
(3) Fillet weld includes socket and seal welds, and attachment for slip-on flanges and branch reinforcement.
(4) Branch connection weld includes pressure containing welds in branches and fabricated laps.
(5) These imperfections are evaluated only for welds 5 mm (3/16 in.) in nominal thickness.
(6) Where two limiting values are separated by "and", the lesser of the values determines acceptance. Where two sets
of values are separated by "or", the larger value is acceptable.
(7) Tightly butted unfused root faces are unacceptable.
(8) For groove welds, height is the lesser of the measurements made from the surfaces of the adjacent components.
For fillet welds, height is measured from the theoretical throat, Fig. 328.5.2A, of ASME/ANSI B31.3 internal
protrusion does not apply.
3. API-1104(Cross country Pipe Lines), ASME/ANSI B31.4,
ASME/ANSI B31.8

Table 3-1 is applicable in determining the size and type of discontinuities


when viewing radiographs for final acceptance in accordance with API-
1104, ASME/ANSI B31.4, Paragraph 434.8.5, and ASME/ANSI B31.8.

Table 3-1 - Acceptance Criteria for API 1104

Indication/Defect Unacceptable if any of the following conditions exist:


Inadequate Penetration (IP) 1. Length of an individual indication of IP exceeds 25.4 mm (1.0").
(without high-low) 2. The aggregate length of indications of IP in any continuous 304.8 mm (12")
length of weld exceeds 25.4 mm (1.0").
3. The aggregate length of indications of IP exceeds 8% of the weld length in any
weld less than 304.8 mm (12") in length.
Inadequate Penetration due to 1. Length of an individual indication of IPD exceeds 50.8 mm (2.0").
High-Low (IPD) 2. The aggregate length of indications of IP in any continuous 304.8 mm (12")
length of weld exceeds 76.2 mm (3.0").
Incomplete Fusion (IF) 1. Length of an individual indication of IF exceeds 25.4 mm (1.0").
2. The aggregate length of indications of IF in any continuous 304.8 mm (12")
length of weld exceeds 25.4 mm (1.0").
3. The aggregate length of indications of IF exceeds 8% of the weld length in any
weld less than 304.8 mm (12") in length.
Incomplete Fusion due to Cold 1. Length of an individual indication of IFD exceeds 50.8 mm (2.0").
Lap (IFD) 2. The aggregate length of indications of IFD in any continuous 304.8 mm (12")
length of weld exceeds 50.8 mm (2.0").
3. The aggregate length of indications of IFD exceeds 8% of the weld length.
Internal Concavity (IC) Any length of IC is acceptable provided the density of the radiographic image of the
IC does not exceed that of the thinnest adjacent base metal. For areas that exceed
the density of the thinnest adjacent base metal, the criteria for burn through are
applicable.
Burn-Through (BT) Pipe OD  2-3/8" Pipe OD < 2-3/8"
1. Maximum dimension exceeds 6.35 1. Maximum dimension exceeds 6.35
mm (¼") and the density of the BT's mm (¼") and the density of the BT's
image exceeds that of the thinnest image exceeds that of the thinnest
adjacent base metal adjacent base metal
2. Maximum dimension exceeds the 2. Maximum dimension exceeds the
thinner of nominal wall thicknesses thinner of nominal wall thicknesses
joined, and the density of the BT's joined, and the density of the BT's
image exceeds that of the thinnest image exceeds that of the thinnest
adjacent base metal adjacent base metal
3. Sum of maximum dimensions of 3. More than one BT of any size is
separate BTs whose image density present and the density of more than
exceeds that of the thinnest adjacent one of the images exceeds that of
base metal exceeds 12.7 mm (½") in the thinnest adjacent base metal.
304.8 mm (12") of weld or the total
weld length, whichever is less.
Table 3-1 - Acceptance Criteria for API 1104 (Cont'd)

Indication/Defect Unacceptable if any of the following conditions exist:


Slag Inclusions Pipe OD 2-3/8" Pipe OD < 2-3/8"
Elongated (ESI) Unacceptable if: Unacceptable if:
Isolated (ISI) 1. ESI length > 2" 1. ESI > 3 X nominal WT of the thinner
Note: ESI indications separated 2. ESI width > 1/16" thickness joined.
by approx. width of root bead 3. Sum of the lengths of ISI > 1/2" in 2. ESI width > 1/16"
(wagon tracks) to be 12" of weld. 3. Sum of ISI lengths > 2 X nominal
considered as a single 4. Width of ISI > 1/8" WT of thinner thickness joined and
indication unless the width of 5. > 4 ISI with maximum width of 1/8" ISI width > 1/2 nominal WT of
either > 1/32". In that event, in any 12" of weld. thinner thickness joined.
they shall be considered as 6. Sum of the lengths of ESI & ISI > 4. Aggregate length of ESI & ISI > 8%
separate indications. 8% of weld length. of weld length.

Porosity - individual / Scattered Unacceptable if:


(P) 1. Size of individual pore > 1/8"
Note: Size based on maximum 2. Size of individual pore > 25% of thinner WT joined
dimensions 3. Distribution of Porosity exceeds API 1104 Porosity Charts.
Porosity - Cluster (CP) Unacceptable if:
1. CP dia. > ½"
2. Aggregate length of CP > ½" in any continuous 12" of weld
3. An individual pore within a cluster > 1/16" in size.
Porosity - Hollow-Bead (HB) Unacceptable if:
1. Length of individual HB > 1/2"
2. Sum of HB lengths > 2" in any continuous 12" of weld
3. Individual HB > 1/4" separated by < 2 "
4. Sum of HB lengths > 8% weld length.
Cracks (C) Any size or location of cracks are unacceptable except for shallow crater or star
cracks. Shallow crater or star crack length > 5/32" is unacceptable.
Undercutting Unacceptable if:
Adjacent to cover pass (EU) 1. Any combination EU & IU length > 2" in any continuous 12" of weld.
Adjacent to root pass (IU) 2. Sum of EU & IU lengths in any combination > 1/6 of weld length.
Tungsten Inclusions Individual tungsten inclusions are be evaluated as rounded indications (Porosity).
Elongated or aligned tungsten inclusions are unacceptable.
Accumulation of Discontinuities Unacceptable if:
Excluding IPD, EU & IU 1. Sum lengths of indications > 2" in any continuous 12" of weld.
2. Sum lengths of indication > 8% of weld length.
Pipe / Fitting Discontinuities Arc burns, long seam discontinuities and other discontinuities in the pipe or fittings
detected by RT shall be recordable.
4. AWS D1.1

Radiographic acceptance criteria for AWS D1.1 is different for


statically Loaded and Dynamically Loaded structures. This SAEP
covers only statically loaded structures. For Dynamically loaded
structures, refer to the appropriate sections of AWS DI.I. If there is doubt
as to the designation of statically or dynamically loaded, refer to the
project engineer for determination. The radiographic film interpreter
should confirm the loading classification prior to preceding the
interpretation of film. Rejection criteria for statically loaded structures are
provided below. Note that to determine the allowable and rejectable size
of discontinuities, the use of both the tables and charts are required.

4.1 Statically Loaded Structures

Table 4-1 (AWS DI.I Paragraph 8.15.3.2) and figure 4-1 together
establish the rejection criteria for radiographic indications of
statically loaded structures. Discontinuities exceeding the
following limitations shall be unacceptable. (E = weld size; T =
material thickness)

Table 4-1 - Rejection Criteria for Statically Loaded Structures, AWS D1.1 Para
8.15.3.2

Indication Rejection Criteria


Cracks None permitted
Elongated Discontinuities > maximum size of chart 4-1
Clearance between discontinuities < minimum clearance allowance of fig 4-1
Rounded Discontinuities > E/3 or > 1/4" for T  2"
> E/3 or > 3/8" for T > 2"
Minimum clearance between a rounded discontinuity > 3/32" to an
acceptable rounded or elongated discontinuity or to an edge or end of
an intersection shall be three (3) times the larger discontinuity.
Isolated Discontinuity, ie. a cluster Sum of greatest dimension > maximum size of a single discontinuity
of rounded indications permitted in Fig. 4-1
Minimum clearance to another cluster or elongated discontinuity or to
an edge or end of an intersecting shall be three (3) times the larger
discontinuity.
Sum of Individual Discontinuities shall not exceed 2E/3 or 3/8" which ever is less in 1" of weld.
each being < 3/32 "
In-Line Discontinuities Sum > E in any length of 6E. Where length of weld is < 6E,
permissible sum shall be proportionately less.
Tungsten Inclusions Individual tungsten inclusions are be evaluated as rounded
indications (Porosity). Elongated or aligned tungsten inclusions are
unacceptable.
Figure 4-1 Weld Quality Requirements for Elongated Discontinuities as
Determined by Radiography for Statically Loaded Structures
(see AWS D1.1 Paragraph 6.15.3.2)

S-ar putea să vă placă și