VD4G generator circuit breaker


Small footprint, full protection
for generator applications

Protect your assets


• Use a solution complitely in accordance
with latest global standard - IEC as well
as IEEE.
• Count on a generator circuit breaker
suitable for all highly demanding
conditions, including out-of-phase
condition and island mode
• Be safe thanks to a completely tested
solution for DC-component up to
130%, so no need to add any time delay
in the protection

Maximize your output


• Experience the easy installation/
integration of VD4G, thanks to its
equivalent interfaces and dimensions
like VD4
• Accelerate your projects with
outstanding technical support from
our field application engineering team
ABB offers its new vacuum
generator circuit breakers at 15 kV, Optimize your investment
• Choose ratings that fit your needs from
4000A, 50 kA in accordance to the 25/16 kA @ 15 kV to 50/50 kA @ 15 kV
new dual logo IEEE/IEC 62271-37-013 • Take advantage of using the same
compact switchgear setup like in
to satisfy your business needs in power distribution systems
power generation applications.

Technical characteristics
Standards IEEE/IEC 62271-37- 013
Circuit breaker VD4G-25 VD4G-40 VD4G-50
Rated voltage Ur kV 15 15 15
Rated normal current (40° C) Ir A 1250 1250 | 1600 | 2000 | 3150 | 4000 3150 | 4000
Rated frequency fr Hz 50 / 60 50 / 60 50 / 60
Withstand voltage at 50 Hz Ud
common value kV 38 38 38
Impulse withstand voltage Up
common value kV 95 95 95
Making current Ip kA 68.5 115 137
Rated system-source short-circuit breaking current
symmetrical short-circuit current Isc kA 25 40 50
DC component of the rated short circuit breaking current % 74 74 74
asymmetrical system source short-circuit current kA 36.5 58.5 73
Symmetrical short-circuit current Iscg Class G1 kA 16 25 50
DC component of generator-source short-circuit breaking
% 110 110 110
current Class G1
Symmetrical short-circuit current Iscg Class G2 kA 16 25 37
DC component of generator-source short-circuit breaking
% 130 130 130
current Class G2
Rated breaking current under out-of-phase conditions
symmetrical short-circuit current Isc kA 12.5 20 25
DC component of the rated short circuit breaking current % 74 74 74
rated operating sequence during short-circuit interruption CO-10 min-CO CO-10 min-CO CO-10 min-CO
Rated short-time withstand current Ik (3 s) kA 25 40 50 * (4s fixed version)
Dimensions
Pole center distance mm 150 210 | 210 | 210 / 275 | 275 | 275 275
Fixed mm 461 610 | 610 | 610 | 636 | 636 636 | 636
Height
Withdrawable mm 632 691 | 691 | 691 | 730 | 730 735 | 735
Fixed mm 424 459 | 459 | 459 | 459 | 459 459 | 459
Depth
Withdrawable mm 664 643 | 643 | 643 | 643 | 643 650 | 650
Fixed mm 450 600 | 600 | 600 / 750 | 750 | 750 750 | 750
Width
Withdrawable mm 503 681 | 681 | 681 / 853 | 853 | 853 851 | 851
Fixed kg 73 146 | 146 | 146 / 158 | 177 | 177 210 | 210
Weight
Withdrawable kg 116 190 | 190 |190 / 205 | 221 | 221 270 | 270
Opening time ms 33...60 33...60 <30
Operating times
Closing time ms 30...60 30...60 <55
48; 110-125; 220-250 V DC
Operating supply voltage
110-125; 220-250 V AC


For more information please contact:
1VCP000668 - Rev.B, it - Flyer VD4G - 2018.09 (gs)


More product information:
abb.com/mediumvoltage
Your contact center:
abb.com/contactcenters
More service information:
abb.com/service

Data and illustration are not binding. We reserve the right to make changes in
the course of technical development.

© Copyright 2018 ABB. All rights reserved.

S-ar putea să vă placă și