5.4 m 7.2 m 7.2 m 5.4 m

5.7 m
2.85 m

l2 = 6.45 m

3.6 m
7.2 m
ln = 6.75 m ln = 4.95 m

All beams and


columns are
7.2 m 450 mm.

2
1. The slab shown supports a superimposed dead load of 1.2 kN/m2 and a live load of 2.9 kN/m2. The slab extends 100 mm past the
exterior face of the column to support an exterior wall that weighs 1.78 kN/m of length of wall. The storey-to-storey height is 2.85 m.
Use 28 MPa concrete and Grade-420 reinforcement.
a) Select slab thickness.
b) Use the direct-design method to compute moments, and then design the reinforcement for column and middle strips running
north and south along column line 2.
c) Use the direct-design method to compute moments, and then design the reinforcement for column and middle strips running
east and west along column line A.

300 mm 5.4 m 5.4 m


300 mm

6m

All columns are 400 mm

6m

3
4
A singly reinforced concrete beam with a width of 250 mm is subjected to an ultimate moment of 270 KN/m. Find the beam depth and area of
steel, then calculate As,max and Mu,max. Use f’c = 30 MPa and fy = 400 MPa.

5
A singly reinforced concrete beam is subjected to an ultimate moment of 330 KN/m. Find the beam depth and area of steel. The material properties
are f’c = 25 MPa and fy = 280 MPa.

6
The doubly reinforced section shown in figure is subjected to a bending moment of a factored value of 200 KN-m. d’ = 50 mm, f’c = 27 MPa, and
fy = 280 MPa. Design the beam depth.

7
The figure shows a T-section that is subjected to an ultimate moment of a value of 220 KN-m. Calculate the required depth and area of steel.
The material properties are f’c = 28 MPa, and fy = 415 MPa.

8
The figure shows a T-section that is subjected to an ultimate moment of a value of 280 KN-m. Calculate the required depth and area of steel.
Use f’c = 28 MPa and fy = 420 MPa.

9
Compute the depth for the T-section shown if it is subjected to an ultimate moment of 380 KN-m. Use f’c = 21 MPa and fy = 400 MPa.

10
For the neutral axis position given in the figure below, calculate the required are of steel and the ultimate moment. Use f’c = 28 MPa and fy = 420
MPa.

11
The figure below shows a plan and two sectional elevations of a reinforced concrete structure. It is required to calculate the loads acting on the
simple beam B1. Live load = 2 KN/m2, Flooring = 1.5 KN/m2, and own weight of brick wall = 4.5 KN/m2. Assume the thickness of the slab is 150
mm.

12
It is required to design the continuous beam shown. The characteristics compressive strength of concrete f’c = 28 MPa. The yield strength of the
longitudinal steel fy = 400 MPa and for the stirrups fy = 280 MPa. The applied unfactored dead load and live loads on all spans are 40 KN/m and
15 KN/m, respectively. These loads can be used for designing the beam for bending as well as for shear. Assume also that the spacing between
the beams on plan is 4.0 m.

13
Design a solid slab spanning between beams, as shown below. In addition to self-weight, the slab carries a characteristic dead load of 1.0 KPa
and an imposed load of 0.5 KPa.

14