Sunteți pe pagina 1din 154

UTRACON STRUCTURAL SYSTEMS PVT LTD.

,
The Concourse, Unit # 104, 7-1-58. Green lands Road, Ameerpet, Hyderabad-500 038
Tel : +91-40-6684 6667 Fax : +91-40-6684 2349 Email : utraconindia@utracon.com, www. utracon.com

“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION


BUILDING WITH ADDITIONAL MGB LOAD TEST RIG &
ESTABILISHING SERVICE FACILITY AT HELICOPTER -MRO
DIVISION, HAL BENGALURU”.

PT DESIGN CALCULATIONS FOR POST-TENSIONED


SLABS

Designed By: S NAGENDRA

Checked By: N LOKESWHWARA REDDY

Approved By: SEELAM PRASAD

Date : 20-03-2019
CONTENTS
1) DESIGN BASIS REPORT

2) TYPICAL DESIGN REPORT FOR PT BEAMS

3) MANUAL CALCULATION FOR (MOMENT RESISTING CAPACITY &


STRESSES)
DESIGN BASIS REPORT
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

DESIGN BRIEF REPORT

Page 1 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

CONTENTS

 Introduction

 Project Description

 Construction Type

 Structural System

 Design Standards and Documents

 Design Loads
6.1 Self Weight
6.2 Super imposed Dead Load
6.3 Live Load
6.4 Wind Load
6.5 Seismic Load
6.6 Prestress Load
6.7 Load Combination

 Material Grade and Properties


7.1. Concrete
7.2. Un-tensioned steel.
7.3. Pre-Stressing Strand

 Design/Detailing Consideration

8.1 Fire Rating & Cover to Reinforcement

8.2 Span to Depth Ratio

8.3 Deflection

8.4 Stress Limits

8.5 Shear
8.5.1 Punching Shear
8.5.2 Oneway Shear

8.6 Detailing of Tendons and Un-tensioned Reinforcement

8.7 Analysis and Design Software

8.8 Stressing

8.9 Pour/Closure Strip

8.10 Design of Structure

 Philosophy for Pre-stress losses

 Form Work and Back Propping

Page 2 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

1. Introduction:

This Design Brief Report (DBR) outlines the basic criteria for the design and detailing of Post- tensioned
Slabs/PT Beams for Proposed Project.

2. Project Description:
The Proposed project consists of Levels of Floors

Content of this document.


This document presents the Post tensioned slabs/Beams design criteria for the project.

3. Construction Type:
Buildings will be constructed with Post Tensioned (PT) with Suggested options. The shuttering for the Layout
for each floor will be provided and the reinforcement and duct for post-tensioned tendons will be laid in
position. The slab will be pre-stressed on achieving the 75% of design strength (Once concrete strength attains
2
25N/mm ).The ducts will be anchored and grouted.

4. Structural System:
The structural system is as specified in the Structural GA drawings released by the Structural Consultant.

5. Design Standards and Documents

Structure shall be designed in accordance with the following standards

IS: 456-2000 Code of practice for plain and reinforced concrete.

IS: 1343-2012 Code of Practice for Pre-stressed Concrete

TR 43 Post Tensioned Concrete floors: Design Handbook

BS: 8110 Structural use of concrete. Code of practice for design and construction

ACI:318M-14 Building code requirements for structural concrete

6. Design Loads

The Post-Tensioned design is limited to the design of Post-Tensioned flat slabs for the self-weight of structural
elements plus the imposed gravity Loads as specified in the GA Drawings.

Page 3 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

6.1 Self Weight.

Self-weight is in accordance to the member size specified in the GA drawing considering the density of concrete
as 25 kN/m3.
Weights of some of the materials used in construction have been extracted from IS: 875 (Part- I) which are as
follows:
Reinforced Concrete 25 kN/m3
Reinforcement/ Structural steel 78.5 kN/m3

6.2 Super Imposed Dead Load & Live Load


As per Structural Drawing mentioned by consultant.

6.3 Wind Load/Seismic Load


It would be based on structural consultant advice.

6.4 Prestress Loads


Prestressing force (P) immediately after tensioning of tendons will be applied along the periphery of the slab or
in pour strip. The modified prestressing force, after allowing for losses due to creep and shrinkage and
relaxation of prestressing steel (P’), will be used for limit state of serviceability.

6.5 Load Combination

SW – Self weight

SDL-Superimposed Dead Load

LL-Live Load

EQ-Earth Quake

WL-Wind Load

P-Initial Prestress

P’-Final Prestress

6.5.1. Load Combinations for Limit State Method


1.5*(SW + SDL + LL) + 1.0*P’
6.5.2. Load Combination for Serviceability at Service

Page 4 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

1.0*(SW + SDL + LL)+1.0*P

6.5.3. Load Combination of Limit State of Serviceability at Transfer


1.0*SW + 1.0*P

7. Material Grade and Properties


Concrete
Minimum grade for structural concrete shall be of grade M35 for post tensioned slabs.

Un-Tensioned Steel

Conventional/Un-tensioned reinforcement bars, having the following minimum Yield Strength shall be used

Flexure - 500 N/mm2 (Fe500)

Shear - 415 N/mm2 (Fe415)


Prestressing Strand
System : USS Bonded Post tensioning System for Slab.
Type : As specified in the Structural DBR
: TYPE -3 as per IS: 1343 -2012
Properties : Uncoated stress relieved low relaxation seven ply
Strand as per IS 14268:1995 (Reaffirmed 1997)

Nominal Tensile Strength, fy : 1860 N/mm2


Young's Modulus : 1.95x10 5 N/mm2
Diameter : 0.5” (12.7 mm) & 0.6''(15.2mm)
Nominal Area : 98.7 mm2 &140 mm2
Specific Breaking Load : 183.7 kN & 260.7 kN
Jacking Force : Applied pre-stressing force for each Strand-0.75x183.7 = 137.775 kN
0.75x260.7 = 195.525 kN
Friction Parameters : µ = 0.2/rad
k = 0.0017/m
Serviceability Classification : As per (IS1343-2012)

8. Design/Detailing Consideration
8.1 Fire Resistance of Elements & Cover to the Reinforcement
All structures will be designed for two hour fire rating. The requirements for fire resistance will be met by
adopting the minimum structural dimensions and clear cover to reinforcement

Page 5 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

Minimum dimension of structural element and Nominal cover to reinforcements will be provided as given IS:
456-2000.
Cover to the reinforcement
Minimum clear cover to any reinforcement shall be provided based on the fire requirements and exposure
condition whichever is more.
Clear Cover to the reinforcement will be provided as per IS 456-2000

8.2 Deflection
Incremental deflection is limited to Span/350 or 20mm, whichever is less.

The total long term deflection of is limited to Span/250.

The total upward deflection (at Transfer) should not exceed span/300.

8.3 Stress Limit

Design will be carried out to meet the serviceability requirements as per Cl 24.2.1(c) of IS 1343:2012

Basic Design Stresses

At Service

Design Compressive Stress : 0.33 Fck & 0.4 Fck As per BS: 8110
Design Hypothetical Flexural Stress : As per Table 10 of IS: 1343-2012.

At Transfer
Design Compressive Stress : IS: 1343-2012.

Characteristic Concrete cube strength at 28 days : fck


Characteristic Concrete cube strength at transfer of prestress : fci

8.4 Shear Check


8.6.1 Punching Shear:
Punching shear check will be carried out for Flat Slab/Flat plate to satisfy ultimate state requirements
according to IS456:2000.
Shear reinforcement required if any, shall be provided in the detailed drawing.
Punching to be checked for one way slab if RCB width less than 50% of column width.

8.6.2 One way Shear:

Page 6 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

One way shear check will be carried out for One-way Slab as per IS 1343-2012.

8.5 Detailing of Tendon and Un-Tensioned Reinforcement

Tendon:
The spacing of distributed tendons shall not exceed 8 to 10 times the thickness of slab.
Minimum P/A value for PT slab = 0.7 to 0.9 N/mm2
Minimum P/A value for PTbeam = 1.2 N/mm2
Un-tensioned reinforcement:
Minimum Un-tensioned reinforcement of 0.12% of total cross sectional area will be provided in Post-tensioned
Slabs. (Reference IS 456-2000).
For roof slabs top mat of minimum 0.1% Gross C/A(unless temperature Analysis was not carried out).
For slabs ≥300mm minimum top mat shall be provide.
Ductile detailing to be followed as per the consultants Advice.
Top and Bottom reinforcing bars in the PT slab shall be extended into the surrounding RC area for minimum
1000mm or Ld, Whichever is maximum, wherever applicable.

8.6 Analysis and Design Software


The analysis will be based on Equivalent frame method and Finite Element Method.
The following software used for the Analysis,
RAPT
SAFE
ETABS
ADAPT
STAAD
.
8.7 Stressing
25% of total jacking force shall be applied as initial pre-stressing at concrete strength of 12.5 Mpa. The total
jacking force of 75% of characteristic tensile strength of strand is applied at concrete strength of 25 Mpa.

8.8 Pour/Closure Strips


Pour/Closure strips are appropriately so as to facilitate the planned pour sequence. The pour strip is designed as
RCC strip stitching pours on either side. Adequate un-tensioned (disconnected) reinforcement is provided in
pour strip to satisfy the ultimate moment condition. Formwork/shuttering have to be retained in the panel (where
pour strip is located) until the concrete in the pour strip achieves the required design strength.

Page 7 of 8
“PROPOSED BUILDING FOR IDS ROH RATE PRODUCTION BUILDING WITH
ADDITIONAL MGB LOAD TEST RIG & ESTABILISHING SERVICE FACILITY AT
HELICOPTER -MRO DIVISION, HAL BENGALURU”.

8.9 Design of Structure


The design of the PT members will be based on the Limit State Method as per IS: 456-2000 and IS: 1343-2012
respectively.

The design of PT slab/beam obtained will be vetted by the structural consultant. The additional reinforcement to
resist seismic loads/Temperature will be provided by the structural consultant if required.

9. Philosophy for Pre-stress losses


For post tensioned members, Loss due to Elastic Shortening, Relaxation of stresses in steel, Shrinkage of
concrete, Creep of concrete, Friction and Anchorage Slip are encountered and are accounted for. Long term
losses (Relaxation of stresses in steel, Shrinkage of concrete, Creep of concrete).

Breaking load of Strand- 183.7 kN/260.7kN

Applied pre-stressing force at site for each Strand-0.75xBreaking Load.

10. Form Work and Back Propping

Formwork shall remain in position until tendons have been fully stressed and the strand elongations results are
satisfactory. The design and erection of shuttering for Slab and the back-propping required for the lower floors,
shall be carried out by the Principal contractors confirming to relevant IS codes.

Page 8 of 8
PT BEAMS RAPT REPORT
ST
1 SLAB
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN REPORT\1PTB-1.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List External
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel External External Edge
Length Depth Width Width Edge Distance
Left Right Distance Left Right
mm mm mm mm mm mm
LE 375
1 13000 150 2400 2400 600 600
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 625 1200 1200 2110

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:50:32 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 22.8 2 375 22.8

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 15 2 375 15

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 2.2 2 375 2.2

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 10 2 375 10 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0

Load Combinations : Transfer Prestress


Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0
RAPT 6.2.2.2 20-03-2019 12:50:32 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Pre Existing
Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

kN/m 1 2
28 L1
21
14
7
0
0 13000mm

Load Case 2 : 2. Initial Dead Load

kN/m 1 2
28
21
14
7 P1
0
0 13000mm
28
21 L1
14
7
0
1 2

Load Case 3 : 3. Live Load

kN/m 1 2
28 P1
21
14
7
0
0 13000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 5 5 2 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 13750

Tendon 1 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 5
RAPT 6.2.2.2 20-03-2019 12:50:33 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Allowable Profiles
Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 263.4 263.4 40 263.4 263.4 417.5 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 625 471.7 471.7 54.2 471.7 471.7 417.5 100 112.39 97.4

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 86.1mm - 2 - 5/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 13375
Height mm 470 465 365 255 170 105 65 45 45 65 105 170 255 365 465 470

Critical Profile Points


Span 1 Locat mm -375 0 385.7 6500 12614.3 13000 13375
Height mm -164.8 -162.1 -185.9 -585 -185.9 -162.1 -164.8

Tendon 1 : - 2 - 5/12.7
mm
0
5

5
-200

-400

-600
470cl

470cl

1 2
465

365

255

170

105

105

170

255

365

465
65

45

45

65

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2
RAPT 6.2.2.2 20-03-2019 12:50:34 Page 5/13
Licensee: License No.: 10255062220211WPN5
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 13000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
RAPT 6.2.2.2 20-03-2019 12:50:34 Page 6/13
Licensee: License No.: 10255062220211WPN5

Crack Width Calculations List Code default


AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
5 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100

Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum


of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 90 0.4 2.7 0.2 0.002 2800
2 23 90 0.4 2.7 0.2 0.002 2800
3 23 90 0.4 2.7 0.2 0.002 2800
4 23 90 0.4 2.7 0.2 0.002 2800
5 23 90 0.4 2.7 0.2 0.002 2800
RAPT 6.2.2.2 20-03-2019 12:50:35 Page 7/13
Licensee: License No.: 10255062220211WPN5
Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 13000mm

Plan view

mm 1 2
-600

600

1200

1800
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:50:35 Page 8/13
Licensee: License No.: 10255062220211WPN5
Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 13000mm
Warnings
Input
No errors or warnings were found.

Output
Warning:SPAN Reinforcing Bar spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See Detailed
Reinforcement Design Comments.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 86.1mm - 2 - 5/12.7

kN 1 2
128

121

114

111
107

100
0 13000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 2 - 5/12.7

kN/m 1 2
500

400

300

200

100

0
0 -23.2 13000mm

Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -73.75 -67.74 -73.75 -67.74 129.88 115.52 136.71
Moment Below kNm -93.09 -85.51 -93.09 -85.51 163.94 145.81 172.56
Reaction kN 0 0 0 0 156.75 139.43 165
Elastic Rotation #.# 0 0 0 0 1.76e-4 1.56e-4 1.85e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Moment Above kNm 73.75 67.74 73.75 67.74 -129.88 -115.52 -136.71
Moment Below kNm 93.09 85.51 93.09 85.51 -163.94 -145.81 -172.56
Reaction kN 0 0 0 0 156.75 139.43 165
Elastic Rotation #.# 0 0 0 0 -1.76e-4 -1.56e-4 -1.85e-4
RAPT 6.2.2.2 20-03-2019 12:50:36 Page 9/13
Licensee: License No.: 10255062220211WPN5

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 314.38 314.38 300.37 505.44 300.37 505.44
Moment Below kNm 396.81 396.81 379.12 637.96 379.12 637.96
Reaction kN 461.18 461.18 444.27 691.77 444.27 691.77
Elastic Rotation #.# 4.25e-4 4.25e-4 4.98e-4 7.75e-4 4.98e-4 7.75e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -314.38 -314.38 -505.44 -300.37 -300.37 -505.44
Moment Below kNm -396.81 -396.81 -637.96 -379.12 -379.12 -637.96
Reaction kN 461.18 461.18 691.77 444.27 444.27 691.77
Elastic Rotation #.# -4.25e-4 -4.25e-4 -7.75e-4 -4.98e-4 -4.98e-4 -7.75e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

kNm 1 2
-1500
-1200 -912 -912
-900
-600
-300
0
300
600
900
1200 975
0 13000mm

Moment Moment 1 Moment 2

1 2
kN
800 616
600
400
200
0
-200
-400
-600
-800 -616
0 13000mm

Shear Shear 1 Shear 2

Flexural Design
Ultimate

1 2
mm2 1385 1401
1500
1200
900
600
300
0
-300
-600
471
0 13000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot
RAPT 6.2.2.2 20-03-2019 12:50:37 Page 10/13
Licensee: License No.: 10255062220211WPN5

1 2
kNm
-1200
-900
-600
-300
0
300
600
900
1200
0 13000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.304

0.303
0.45
0.36
0.27
0.18
0.09
0
-0.09

0.118
-0.18
-0.27
0 13000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

1 2
MPa MPa
-4 -2.83 -200
-2 -100
0 0
2 100
4 200
6 300
8 400
10 500
12 600
14 6.27 700
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits

Reversal Moment Condition

1 2
MPa MPa
-4 -2.83 -200
-2 -100
0 0
2 100
4 200
6 300
8 400
10 500
12 600
14 6.27 700
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.
RAPT 6.2.2.2 20-03-2019 12:50:37 Page 11/13
Licensee: License No.: 10255062220211WPN5
Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-0.6 -10
-0.3 -5
0 0
0.3 5
0.6 10
0
0.9 15
1.2 20
1.5 25
1.8 1.75 30
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

1 2
MPa MPa
-2 -1.22 -18
-1 -9
0 0
1 9
2 18
3 27
4 36
5 45
6 4.15 54
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

1 2
MPa MPa
-2 -1.22 -18
-1 -9
0 0
1 9
2 18
3 27
4 36
5 45
6 4.15 54
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 616.35 -912.46 406.73 509.3 1385.15 1080 1.84e5 1004.86 1004.86 2603.39 1.2 84 131.2 188.8 Minimum Steel
875 566.04 -616.86 338.01 433.9 400.23 1080 469.61 991.75 469.61 2217.76 1.2 84 131.2 188.8 Minimum Steel
1350 518.24 -359.34 278.08 351.8 98.45 1080 422.88 979.34 422.88 1798.24 1.2 84 131.2 188.8 Minimum Steel
1825 471.91 -135.15 223.49 282.8 0 1080 714.5 967.21 714.5 1445.63 1.2 84 131.2 188.8 Minimum Steel
2300 424.12 77.65 82.62 386.3 0 1080 463.77 955.65 463.77 1974.44 1.2 84 131.2 188.8 Minimum Steel
2775 376.32 267.76 126.31 425.7 0 1080 271.96 944.48 271.96 2175.71 1.2 84 131.2 188.8 Minimum Steel
3250 335.21 394.94 164.85 460.3 0 1080 294.11 933.51 294.11 2352.86 1.2 84 131.2 188.8 Minimum Steel
4333 226.24 698.97 233.25 521.7 0 1080 333.32 908.63 333.32 2666.54 1.2 84 131.2 188.8 Minimum Steel
5416 131.89 824.98 273.65 560.9 292.57 1080 358.38 882.21 358.38 2867.06 1.2 84 131.2 188.8 Minimum Steel
6500 47.01 828.11 286.63 570.2 470.76 1080 364.33 855.64 364.33 2914.65 1.2 84 131.2 188.8 Minimum Steel
7583 -131.79 825.12 272.36 560.9 292.9 1080 358.39 879.81 358.39 2867.16 1.2 84 131.2 188.8 Minimum Steel
8666 -226.14 699.19 230.71 521.7 0 1080 333.35 903.34 333.35 2666.77 1.2 84 131.2 188.8 Minimum Steel
9750 -335.21 394.94 160.95 460.3 0 1080 294.11 924.72 294.11 2352.86 1.2 84 131.2 188.8 Minimum Steel
RAPT 6.2.2.2 20-03-2019 12:50:38 Page 12/13
Licensee: License No.: 10255062220211WPN5

Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
10225 -376.32 267.76 121.84 425.7 0 1080 271.96 933.95 271.96 2175.71 1.2 84 131.2 188.8 Minimum Steel
10700 -424.12 77.65 77.58 386.3 0 1080 442.94 943.28 442.94 1974.44 1.2 84 131.2 188.8 Minimum Steel
11175 -471.91 -135.15 216.39 282.8 0 1080 695.9 952.88 695.9 1445.63 1.2 84 131.2 188.8 Minimum Steel
11650 -518.24 -359.34 270.26 354.8 114.58 1080 417.67 962.95 417.67 1813.37 1.2 84 131.2 188.8 Minimum Steel
12125 -566.04 -616.86 329.73 430.5 362.56 1080 463.32 973.75 463.32 2200.63 1.2 84 131.2 188.8 Minimum Steel
12625 -616.35 -912.46 398.48 509.6 1400.62 1080 1.88e5 986.24 986.24 2604.87 1.2 84 131.2 188.8 Minimum Steel

1 2
mm
180
160
140
120
100
80
60
40
20
131 *
0
0 13000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

1 2
kN
900
616
600
300
0
-300
-600
-616
-900
0 13000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

mm 1 2
0
-0.19
-8

-16

-24

-32 67844
0 13000mm

Short Term

mm 1 2
0

-8 -5.73

-16

-24

-32 2247
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:50:38 Page 13/13
Licensee: License No.: 10255062220211WPN5
Incremental

mm 1 2
0

-8
-8.45
-16

-24

-32 1523
0 13000mm

Total Long Term

mm 1 2
0

-8

-11.3
-16

-24

-32 1142
0 13000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 1ST SLAB Date         : 20‐03‐2019

Location  :  1PTB‐1


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 625 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 2110 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 10 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 10 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 987 mm
Effective depth of section with respect to 1st Layer tendon  = 571
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 571.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.044
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.095
xu  = 54.124
Moment resisting capacity of section by Tendons  = 876 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T20)
Ast  = 2
2286 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 600 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 485 kN‐m
Design Moment at critical section  = 975 kN‐m
Total Flexural capacity of section  = 1360 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 886500 mm2
Area of flange  = 316500
Area of web  = 570000
Y1  = 75
Y2  = 387.5
Depth of Neutral axis from top fiber yt  = 275.93
Depth of Neutral axis from bottom fiber yb  = 349.07
Moment of Inertia of T section Ixx  = 31183919734

Section modulas zt  = 1E+08
Section modulas zb  = 9E+07
Eccentricity e  = 295.1 mm

Available tendon force at service (1st Layer)  = 111 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 111.0 kN
Total effective force @ Service P  = 1110 kN
Moment due to self weight  = 186 kN‐m
Moment due to super imposed dead load  = 166 kN‐m
Moment due to Live load  = 196 kN‐m
Secondary Moment  = 153 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 701 kN‐m
Stress due to direct prestress  = P/A
 = 1.25
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 2.90
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 3.67
Stress due to Applied loads @ Top fiber  = M/Zt

 = 6.20
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 7.85

ƒt 2
Stress at extreme top fiber  = 4.56 N/mm
Stress at extreme bottom fiber ƒb  = ‐2.93 N/mm2
Negative sign indicates Tensile stress.
ND
2 SLAB
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN REPORT\2PTB-6.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 375
1 13000 150 3500 3500
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3500 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3500 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 700 1200 1200 3020

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:51:57 Page 2/14
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 -375 29.05 2 375 29.05

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 10 2 375 10

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 2.2 2 375 2.2

2. Initial Dead Load - Point


Load Reference Distance to Load Load Description
column Load from Length
reference
column
mm kN mm A
1 1 3230 120 450 FC
2 1 9620 120 450 FC

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 10 2 375 10 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0
RAPT 6.2.2.2 20-03-2019 12:51:58 Page 3/14
Licensee: License No.: 10255062220211WPN5
Load Combinations : Transfer Prestress
Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0

Load Combinations : Pre Existing


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

1 2
kN/m
40
30 L1
20
10
0
0 13000mm

Load Case 2 : 2. Initial Dead Load

1 2
kN/m kN
40 160
1 2
30 120
20 80
10 40
0 0
0 13000mm
40 160
30 120
20 80
10 P1 40
0 0
0 13000mm
40 160
30 120
20 80
L1
10 40
0 0
1 2

Load Case 3 : 3. Live Load

1 2
kN/m
40 P1
30
20
10
0
0 13000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 4 4 4 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 13750
RAPT 6.2.2.2 20-03-2019 12:51:58 Page 4/14
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Drape Locations
Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 4

Tendon 1 : - Allowable Profiles


Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 270 270 40 270 270 490.3 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 700 544.5 544.5 54.2 544.5 544.5 490.3 100 110.43 141.2

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 85.2mm - 4 - 4/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 13375
Height mm 545 535 420 295 195 120 70 45 45 70 120 195 295 420 535 545

Critical Profile Points


Span 1 Locat mm -375 0 448.6 6500 12551.4 13000 13375
Height mm -167 -164.3 -197 -660 -197 -164.3 -167

Tendon 1 : - 4 - 4/12.7
mm
0
4

-200

-400

-600
545cl

545cl

1 2
535

420

295

195

120

120

195

295

420

535
70

45

45

70

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
RAPT 6.2.2.2 20-03-2019 12:51:59 Page 5/14
Licensee: License No.: 10255062220211WPN5

Reinforcement Reinforcement Preferred Number


Use Type Bar Size of Legs
List List #
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2

Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 13000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
RAPT 6.2.2.2 20-03-2019 12:52:00 Page 6/14
Licensee: License No.: 10255062220211WPN5

Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
Crack Width Calculations List Code default
AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
4 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100
RAPT 6.2.2.2 20-03-2019 12:52:00 Page 7/14
Licensee: License No.: 10255062220211WPN5
Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum
of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 70 0.4 2.7 0.2 0.002 2800
2 23 70 0.4 2.7 0.2 0.002 2800
3 23 70 0.4 2.7 0.2 0.002 2800
4 23 70 0.4 2.7 0.2 0.002 2800

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 13000mm
RAPT 6.2.2.2 20-03-2019 12:52:01 Page 8/14
Licensee: License No.: 10255062220211WPN5
Plan view

1 2
mm
-1600

-800

800

1600
0 13000mm

Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 13000mm
Warnings
Input
No errors or warnings were found.

Output
No errors or warnings were found.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 85.2mm - 4 - 4/12.7

1 2
kN
126

117

108 109

99

90
0 13000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 4 - 4/12.7

kN/m 1 2
800

600

400

200

0
0 -43.4 13000mm
RAPT 6.2.2.2 20-03-2019 12:52:01 Page 9/14
Licensee: License No.: 10255062220211WPN5
Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -144.72 -132.37 -144.72 -132.37 160.71 215.02 193.62
Moment Below kNm -190.34 -174.1 -190.34 -174.1 211.38 282.81 254.66
Reaction kN 0 0 -0 -0 199.73 243.22 240.63
Elastic Rotation #.# 0 0 -1.32e-4 -1.21e-4 1.47e-4 1.97e-4 1.77e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Moment Above kNm 144.72 132.37 144.72 132.37 -160.71 -214.19 -193.62
Moment Below kNm 190.34 174.1 190.34 174.1 -211.38 -281.72 -254.66
Reaction kN 0 0 -0 -0 199.73 240.16 240.63
Elastic Rotation #.# 0 0 1.32e-4 1.21e-4 -1.47e-4 -1.96e-4 -1.77e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 436.98 436.98 431.23 721.65 431.23 721.65
Moment Below kNm 574.75 574.75 567.18 949.18 567.18 949.18
Reaction kN 683.58 683.58 664.43 1025.37 664.43 1025.37
Elastic Rotation #.# 4e-4 4e-4 5.15e-4 7.81e-4 5.15e-4 7.81e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -436.16 -436.16 -720.42 -429.99 -429.99 -720.42
Moment Below kNm -573.67 -573.67 -947.55 -565.56 -565.56 -947.55
Reaction kN 680.52 680.52 1020.77 659.84 659.84 1020.77
Elastic Rotation #.# -3.99e-4 -3.99e-4 -7.8e-4 -5.14e-4 -5.14e-4 -7.8e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

1 2
kNm
-2000
-1500 -1321 -1320
-1000
-500
0
500
1000
1500
2000 1507
0 13000mm

Moment Moment 1 Moment 2

1 2
kN
1200 933
900
600
300
0
-300
-600
-900
-1200 -929
0 13000mm

Shear Shear 1 Shear 2


RAPT 6.2.2.2 20-03-2019 12:52:02 Page 10/14
Licensee: License No.: 10255062220211WPN5
Flexural Design
Ultimate

1 2
mm2
1200 1032 1068
1000
800
600
400
200
0
-200
-400 0
0 13000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot

1 2
kNm
-1500
-1000
-500
0
500
1000
1500
2000
0 13000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.6
0.356

0.355
0.5
0.4
0.3
0.2
0.1
0
-0.1
0.104

-0.2
-0.3
-0.4
-0.5
0 13000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

1 2
MPa MPa
-4 -2.22 -80
-2 -40
0 0
2 40
4 80
6 120
8 160
10 200
12 6.54 240
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension
RAPT 6.2.2.2 20-03-2019 12:52:03 Page 11/14
Licensee: License No.: 10255062220211WPN5
Reversal Moment Condition

1 2
MPa MPa
-4 -2.22 -80
-2 -40
0 0
2 40
4 80
6 120
8 160
10 200
12 6.54 240
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-0.5 -0.23 -10
0 0
0.5 10
1 20
1.5 30
2 40
2.5 50
3 60
3.5 2.97 70
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Span 1
Design Comments:-
- Tension stress in concrete at transfer but within code limits. Consideration should be given to providing crack control reinforcement at the tension
face.BS 8110 cl.4.3.5.2

Permanent
Maximum Moment Condition

1 2
MPa MPa
-0.48
-0.8 -3
0 0
0.8 3
1.6 6
2.4 9
3.2 12
4 15
4.8 4.26 18
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension
RAPT 6.2.2.2 20-03-2019 12:52:03 Page 12/14
Licensee: License No.: 10255062220211WPN5
Reversal Moment Condition

1 2
MPa MPa
-0.48
-0.8 -3
0 0
0.8 3
1.6 6
2.4 9
3.2 12
4 15
4.8 4.26 18
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm
375 933.47 -1321.07 769.95 562.7 1032.04 1013.3 1.86e5 1194.3 1194.3 2698.7 1.12 89.6 139.8 201.2
935 864.8 -817.56 628.62 491.8 613.33 1013.3 805.94 1201.92 805.94 2358.8 1.12 89.6 139.8 201.2
1349 814.03 -470.04 532.45 383.5 0 1013.3 852.52 1183.91 852.52 1839.27 1.12 89.6 139.8 201.2
1763 765.44 -159.59 444.25 332.7 0 1013.3 1812.88 1166.7 1166.7 1595.6 1.12 89.6 139.8 201.2
2177 712.42 162.07 116.78 413.9 0 1013.3 530.22 1148.04 530.22 1984.81 1.22 82.5 128.7 185.2
2591 661.65 446.5 190.86 456.2 0 1013.3 353.83 1129.84 353.83 2187.67 1.87 53.8 84 120.9
3005 610.88 709.92 257.71 494.2 0 1013.3 311.97 1112.06 311.97 2370.12 1.68 60 93.7 134.8
3230 504.35 761.61 290.93 513.1 0 1013.3 307.59 1102.38 307.59 2460.73 1.12 89.6 139.8 201.2
3250 494.94 771.6 293.77 514.7 0 1013.3 308.56 1101.5 308.56 2468.49 1.12 89.6 139.8 201.2
3455 387.8 862.09 321.81 530.7 0 1013.3 318.16 1092.44 318.16 2545.3 1.12 89.6 139.8 201.2
4977 222.57 1212.65 472.24 617 0 1013.3 369.89 1024.01 369.89 2959.14 1.12 89.6 139.8 201.2
6500 71.12 1290.92 521.34 645.8 0 1013.3 387.15 955.08 387.15 3097.21 1.12 89.6 139.8 201.2
7947 -208.66 1235.86 473.83 619.8 0 1013.3 371.57 1015.65 371.57 2972.58 1.12 89.6 139.8 201.2
9395 -364.82 932.17 334.54 541.8 0 1013.3 324.79 1073.6 324.79 2598.34 1.12 89.6 139.8 201.2
9620 -482.41 836.86 304.6 525 0 1013.3 314.72 1082.21 314.72 2517.78 1.12 89.6 139.8 201.2
9750 -550.35 769.73 286.24 514.7 0 1013.3 308.56 1087.03 308.56 2468.49 1.3 77.3 120.6 173.6
9845 -587.9 788.53 272.32 506.9 0 1013.3 303.9 1090.49 303.9 2431.2 1.55 64.8 101.1 145.6
10289 -642.34 515.42 202.16 467.6 0 1013.3 333.41 1106.59 333.41 2242.66 1.83 55 85.8 123.4
10733 -696.79 218.13 123.66 423.4 0 1013.3 439.78 1122.9 439.78 2030.65 1.68 59.8 93.3 134.4
11177 -753.49 -119.4 415.96 325.7 0 1013.3 2209.63 1139.62 1139.62 1561.98 1.12 89.6 139.8 201.2
11621 -805.76 -449.15 509.68 379.7 0 1013.3 848.47 1156.98 848.47 1820.93 1.12 89.6 139.8 201.2
12065 -860.2 -819 612.55 486 524.42 1013.3 784.59 1175.22 784.59 2331 1.12 89.6 139.8 201.2
12625 -928.88 -1319.94 753.98 563.6 1067.98 1013.3 1.91e5 1168.16 1168.16 2703.02 1.12 89.6 139.8 201.2

Shear Comments

A
Minimum Steel
Minimum Steel
Minimum Steel
Minimum Steel

Minimum Steel
Minimum Steel
Minimum Steel
Minimum Steel
Minimum Steel
Minimum Steel
Minimum Steel
Minimum Steel

Minimum Steel
Minimum Steel
RAPT 6.2.2.2 20-03-2019 12:52:04 Page 13/14
Licensee: License No.: 10255062220211WPN5

Shear Comments

A
Minimum Steel
Minimum Steel

mm 1 2
200
180
160
140
120
100
80
60
40
20
84 *
0
0 13000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

1 2
kN
1600
1200 933
800
400
0
-400
-800
-1200 -929
-1600
0 13000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

1 2
mm
0
1.02

-7

-14

-21

-28 12699
0 13000mm

Short Term

1 2
mm
0

-7 -4.86

-14

-21

-28 2663
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:52:04 Page 14/14
Licensee: License No.: 10255062220211WPN5
Incremental

1 2
mm
0

-7
-7.28
-14

-21

-28 1778
0 13000mm

Total Long Term

1 2
mm
0

-7
-9.51
-14

-21

-28 1361
0 13000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 2ND SLAB Date         : 20‐03‐2019

Location  :  2PTB‐6


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 700 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 3020 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 16 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 16 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1579 mm
Effective depth of section with respect to 1st Layer tendon  = 646
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 646.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.043
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.094
xu  = 60.496
Moment resisting capacity of section by Tendons  = 1586 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T20)
Ast  = 2
2286 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 675 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 550 kN‐m
Design Moment at critical section  = 1507 kN‐m
Total Flexural capacity of section  = 2136 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 1E+06 mm2
Area of flange  = 453000
Area of web  = 660000
Y1  = 75
Y2  = 425
Depth of Neutral axis from top fiber yt  = 282.55
Depth of Neutral axis from bottom fiber yb  = 417.45
Moment of Inertia of T section Ixx  = 50393478774

Section modulas zt  = 2E+08
Section modulas zb  = 1E+08
Eccentricity e  = 363.5 mm

Available tendon force at service (1st Layer)  = 109 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 109.0 kN
Total effective force @ Service P  = 1744 kN
Moment due to self weight  = 240 kN‐m
Moment due to super imposed dead load  = 272 kN‐m
Moment due to Live load  = 289 kN‐m
Secondary Moment  = 306 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 1107 kN‐m
Stress due to direct prestress  = P/A
 = 1.57
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 3.55
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 5.25
Stress due to Applied loads @ Top fiber  = M/Zt

 = 6.21
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 9.17

ƒt 2
Stress at extreme top fiber  = 4.22 N/mm
Stress at extreme bottom fiber ƒb  = ‐2.35 N/mm2
Negative sign indicates Tensile stress.
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN REPORT\2PTB-8,10,12.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 375
1 14000 150 3500 3500
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3500 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3500 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 700 1200 1200 3160

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:52:43 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 -375 29.05 2 375 29.05

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 10 2 375 10

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 2.2 2 375 2.2

2. Initial Dead Load - Point


Load Reference Distance to Load Load Description
column Load from Length
reference
column
mm kN mm A
1 1 3860 120 600 SC2
2 1 7935 120 600 SC2

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 10 2 375 10 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0
RAPT 6.2.2.2 20-03-2019 12:52:43 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Transfer Prestress
Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0

Load Combinations : Pre Existing


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

1 2
kN/m
40
30 L1
20
10
0
0 14000mm

Load Case 2 : 2. Initial Dead Load

1 2
kN/m kN
40 160
1 2
30 120
20 80
10 40
0 0
0 14000mm
40 160
30 120
20 80
10 P1 40
0 0
0 14000mm
40 160
30 120
20 80
L1
10 40
0 0
1 2

Load Case 3 : 3. Live Load

1 2
kN/m
40 P1
30
20
10
0
0 14000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 5 5 4 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 14750
RAPT 6.2.2.2 20-03-2019 12:52:44 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Drape Locations
Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 5

Tendon 1 : - Allowable Profiles


Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 266.1 266.1 40 266.1 266.1 490.2 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 700 544.4 544.4 54.2 544.4 544.4 490.2 100 111.07 153

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 92.1mm - 4 - 5/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 14375
Height mm 545 535 430 310 215 135 85 50 40 50 85 135 215 310 430 535 545

Critical Profile Points


Span 1 Locat mm -375 0 417.8 7000 13582.2 14000 14375
Height mm -167.1 -164.4 -192.6 -660 -192.6 -164.4 -167.1

Tendon 1 : - 4 - 5/12.7
mm
0
5

-200

-400

-600
545cl

545cl

1 2
535

430

310

215

135

135

215

310

430

535
85

50

40

50

85

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
RAPT 6.2.2.2 20-03-2019 12:52:45 Page 5/13
Licensee: License No.: 10255062220211WPN5

Reinforcement Reinforcement Preferred Number


Use Type Bar Size of Legs
List List #
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2

Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 14000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
RAPT 6.2.2.2 20-03-2019 12:52:45 Page 6/13
Licensee: License No.: 10255062220211WPN5

Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
Crack Width Calculations List Code default
AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
5 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100
RAPT 6.2.2.2 20-03-2019 12:52:46 Page 7/13
Licensee: License No.: 10255062220211WPN5
Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum
of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 90 0.4 2.7 0.2 0.002 2800
2 23 90 0.4 2.7 0.2 0.002 2800
3 23 90 0.4 2.7 0.2 0.002 2800
4 23 90 0.4 2.7 0.2 0.002 2800
5 23 90 0.4 2.7 0.2 0.002 2800

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 14000mm
RAPT 6.2.2.2 20-03-2019 12:52:46 Page 8/13
Licensee: License No.: 10255062220211WPN5
Plan view

1 2
mm
-1600

-800

800

1600
0 14000mm

Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 14000mm
Warnings
Input
No errors or warnings were found.

Output
No errors or warnings were found.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 92.1mm - 4 - 5/12.7

1 2
kN
126

117

108 110

99

90
0 14000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 4 - 5/12.7

kN/m 1 2
1000

800

600

400

200

0
0 -46.5 14000mm
RAPT 6.2.2.2 20-03-2019 12:52:47 Page 9/13
Licensee: License No.: 10255062220211WPN5
Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -187.85 -171.04 -187.85 -171.04 187.37 278.57 225.72
Moment Below kNm -247.07 -224.96 -247.07 -224.96 246.44 366.4 296.89
Reaction kN -0 0 0 0 214.26 274.79 258.13
Elastic Rotation #.# 0 0 -1.72e-4 -1.56e-4 1.71e-4 2.55e-4 2.06e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Moment Above kNm 187.85 171.04 187.85 171.04 -187.37 -246.23 -225.72
Moment Below kNm 247.07 224.96 247.07 224.96 -246.44 -323.86 -296.89
Reaction kN 0 0 0 0 214.26 226.29 258.13
Elastic Rotation #.# 0 0 1.72e-4 1.56e-4 -1.71e-4 -2.25e-4 -2.06e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 520.62 520.62 527.87 866.45 527.87 866.45
Moment Below kNm 684.76 684.76 694.29 1139.63 694.29 1139.63
Reaction kN 747.17 747.17 733.57 1120.76 733.57 1120.76
Elastic Rotation #.# 4.76e-4 4.76e-4 6.39e-4 9.49e-4 6.39e-4 9.49e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -488.28 -488.28 -817.94 -479.35 -479.35 -817.94
Moment Below kNm -642.22 -642.22 -1075.81 -630.48 -630.48 -1075.81
Reaction kN 698.67 698.67 1048.01 660.82 660.82 1048.01
Elastic Rotation #.# -4.47e-4 -4.47e-4 -9.05e-4 -5.95e-4 -5.95e-4 -9.05e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

1 2
kNm
-2400
-1620 -1535
-1800
-1200
-600
0
600
1200
1800
2400 1939
0 14000mm

Moment Moment 1 Moment 2

1 2
kN
1200 1029
900
600
300
0
-300
-600
-900
-1200 -956
0 14000mm

Shear Shear 1 Shear 2


RAPT 6.2.2.2 20-03-2019 12:52:48 Page 10/13
Licensee: License No.: 10255062220211WPN5
Flexural Design
Ultimate

1 2
mm2
1831 1367
2000
1600
1200
800
400
0
-400
-800 0
0 14000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot

1 2
kNm
-1800
-1200
-600
0
600
1200
1800
2400
0 14000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.445

0.426
0.6
0.4
0.2
0
-0.2
0.125

-0.4

0 14000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

1 2
MPa MPa
-3.05
-4 -106.67
-2 -53.33
0 0
2 53.33
4 106.67
6 160
8 213.33
10 266.67
12 7.93 320
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension
RAPT 6.2.2.2 20-03-2019 12:52:48 Page 11/13
Licensee: License No.: 10255062220211WPN5
Reversal Moment Condition

1 2
MPa MPa
-3.05
-4 -106.67
-2 -53.33
0 0
2 53.33
4 106.67
6 160
8 213.33
10 266.67
12 7.93 320
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Transfer Prestress
Maximum Moment Condition

1 2
MPa -0.52 MPa
-0.7 -7
0 0
0.7 7
1.4 14
2.1 21
2.8 28
3.5 35
4.2 3.77 42
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Span 1
Design Comments:-
- Tension stress in concrete at transfer but within code limits. Consideration should be given to providing crack control reinforcement at the tension
face.BS 8110 cl.4.3.5.2

Permanent
Maximum Moment Condition

1 2
MPa MPa
-2 -1.11 -8
-1 -4
0 0
1 4
2 8
3 12
4 16
5 20
6 5.26 24
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension
RAPT 6.2.2.2 20-03-2019 12:52:49 Page 12/13
Licensee: License No.: 10255062220211WPN5
Reversal Moment Condition

1 2
MPa MPa
-2 -1.11 -8
-1 -4
0 0
1 4
2 8
3 12
4 16
5 20
6 5.26 24
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 1028.85 -1620.54 972.42 572.1 1830.81 960 2.1e5 1251.54 1251.54 2599.23 1.06 94.5 147.5 212.4 Minimum Steel
935 960.18 -1063.61 806.43 480.6 485.86 960 842.75 1238.1 842.75 2183.43 1.06 94.5 147.5 212.4 Minimum Steel
1448 897.27 -587.17 667.9 380.9 0 960 935.48 1213.87 935.48 1730.5 1.06 94.5 147.5 212.4 Minimum Steel
1961 377.46 166.91 57.98 376.7 0 960 223.33 1190.98 223.33 1711.56 1.13 88.7 138.5 199.3
2474 771.39 269 172.17 428.7 0 960 522.15 1167.11 522.15 1947.83 1.61 62.4 97.5 140.3
2987 708.48 648.59 274.26 475.1 0 960 375.87 1143.45 375.87 2158.75 1.94 51.9 80.9 116.5
3500 645.57 995.9 364.5 516 0 960 332.92 1120.38 332.92 2344.34 1.68 59.9 93.5 134.6
3560 638.21 1034.42 374.27 520.4 0 960 329.45 1117.71 329.45 2364.39 1.64 61.2 95.5 137.5
3860 524.32 1128.68 420.56 541.3 0 960 307.43 1104.18 307.43 2459.44 1.11 90.6 141.4 203.5
4160 397.53 1266.96 462.43 560.3 0 960 318.23 1090.23 318.23 2545.82 1.06 94.5 147.5 212.4 Minimum Steel
5580 246.39 1600.32 603.02 624.4 0 960 354.64 1022.75 354.64 2837.1 1.06 94.5 147.5 212.4 Minimum Steel
7000 110.26 1689.79 648.59 645.8 0 960 366.77 953.88 366.77 2934.19 1.06 94.5 147.5 212.4 Minimum Steel
7635 -82.05 1651.83 638.39 641.5 0 960 364.35 982.94 364.35 2914.77 1.06 94.5 147.5 212.4 Minimum Steel
7935 -204.17 1759.92 627.05 636.5 0 960 361.51 996.6 361.51 2892.09 1.06 94.5 147.5 212.4 Minimum Steel
8235 -330.96 1679.65 611.53 629.6 0 960 357.59 1010.21 357.59 2860.75 1.06 94.5 147.5 212.4 Minimum Steel
9367 -446.78 1355.71 512.67 586.4 0 960 333.05 1057.14 333.05 2664.41 1.06 94.5 147.5 212.4 Minimum Steel
10500 -572.83 853.62 354.26 516 0 960 336.1 1102.55 336.1 2344.34 1.27 79.1 123.5 177.8
11013 -635.73 543.62 263.21 475.1 0 960 384.79 1123.07 384.79 2158.75 1.46 68.7 107.3 154.4
11526 -701.01 184.35 160.21 428.7 0 960 617.07 1143.83 617.07 1947.83 1.06 94.5 147.5 212.4 Minimum Steel
12039 -763.92 -191.41 523.44 323.3 0 960 1784.77 1165.05 1165.05 1468.89 1.06 94.5 147.5 212.4 Minimum Steel
12552 -824.52 -580.18 648.99 380.9 0 960 859.5 1186.97 859.5 1730.5 1.06 94.5 147.5 212.4 Minimum Steel
13065 -887.43 -1019.3 787.5 473.7 376.67 960 803.26 1209.9 803.26 2152.11 1.06 94.5 147.5 212.4 Minimum Steel
13625 -956.1 -1535.49 953.14 564.2 1367.29 960 2e5 1222.19 1222.19 2563.35 1.06 94.5 147.5 212.4 Minimum Steel

mm 1 2
210
180
150
120
90
60
30
80.9 *
0
0 14000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12


RAPT 6.2.2.2 20-03-2019 12:52:49 Page 13/13
Licensee: License No.: 10255062220211WPN5

1 2
kN
1200 1029
800
400
0
-400
-800
-1200 -956
-1600
0 14000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

1 2
mm
0 1.78

-10

-20

-30
7855
0 14000mm

Short Term

1 2
mm
0

-10 -6.63

-20

-30
2103
0 14000mm

Incremental

1 2
mm
0

-10
-9.91
-20

-30
1407
0 14000mm

Total Long Term

1 2
mm
0

-10
-13.1
-20

-30
1066
0 14000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 2ND SLAB Date         : 20‐03‐2019

Location  :  2PTB‐8,10,12


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 700 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 3160 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 20 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 20 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1974 mm
Effective depth of section with respect to 1st Layer tendon  = 646
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 646.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.051
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.112
xu  = 72.36
Moment resisting capacity of section by Tendons  = 1967 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T20)
Ast  = 2
2286 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 675 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 550 kN‐m
Design Moment at critical section  = 2027 kN‐m
Total Flexural capacity of section  = 2517 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 1E+06 mm2
Area of flange  = 474000
Area of web  = 660000
Y1  = 75
Y2  = 425
Depth of Neutral axis from top fiber yt  = 278.7
Depth of Neutral axis from bottom fiber yb  = 421.3
Moment of Inertia of T section Ixx  = 51320694444

Section modulas zt  = 2E+08
Section modulas zb  = 1E+08
Eccentricity e  = 367.3 mm

Available tendon force at service (1st Layer)  = 110 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 110.0 kN
Total effective force @ Service P  = 2200 kN
Moment due to self weight  = 276 kN‐m
Moment due to super imposed dead load  = 420 kN‐m
Moment due to Live load  = 332 kN‐m
Secondary Moment  = 396 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 1424 kN‐m
Stress due to direct prestress  = P/A
 = 1.94
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 4.39
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 6.63
Stress due to Applied loads @ Top fiber  = M/Zt

 = 7.73
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 11.69

ƒt 2
Stress at extreme top fiber  = 5.29 N/mm
Stress at extreme bottom fiber ƒb  = ‐3.12 N/mm2
Negative sign indicates Tensile stress.
RD
3 SLAB
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN REPORT\3PTB-1.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List External
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel External External Edge
Length Depth Width Width Edge Distance
Left Right Distance Left Right
mm mm mm mm mm mm
LE 375
1 13000 150 2400 2400 600 600
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 700 1200 1200 2110

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:53:22 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 -375 25.01 2 375 25.01

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 15 2 375 15

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 2.2 2 375 2.2

2. Initial Dead Load - Point


Load Reference Distance to Load Load Description
column Load from Length
reference
column
mm kN mm A
1 1 3230 120 450 SC1
2 1 9620 120 450 SC1

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 10 2 375 10 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0
RAPT 6.2.2.2 20-03-2019 12:53:23 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Transfer Prestress
Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0

Load Combinations : Pre Existing


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

1 2
kN/m
28 L1
21
14
7
0
0 13000mm

Load Case 2 : 2. Initial Dead Load

1 2
kN/m kN
28 1 2 140
21 105
14 70
7 35
0 0
0 13000mm
28 140
21 105
14 70
7 P1 35
0 0
0 13000mm
28 140
21 L1 105
14 70
7 35
0 0
1 2

Load Case 3 : 3. Live Load

1 2
kN/m
28 P1
21
14
7
0
0 13000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 4 4 3 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 13750
RAPT 6.2.2.2 20-03-2019 12:53:23 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Drape Locations
Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 4

Tendon 1 : - Allowable Profiles


Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 299 299 40 299 299 491.8 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 700 546 546 54.2 546 546 491.8 100 112.64 125.8

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 85.3mm - 3 - 4/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 13375
Height mm 545 535 425 295 195 120 70 45 45 70 120 195 295 425 535 545

Critical Profile Points


Span 1 Locat mm -375 0 449.9 6500 12550.1 13000 13375
Height mm -165.5 -162.8 -195.7 -660 -195.7 -162.8 -165.5

Tendon 1 : - 3 - 4/12.7
mm
0
4

-200

-400

-600
545cl

545cl

1 2
535

425

295

195

120

120

195

295

425

535
70

45

45

70

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
RAPT 6.2.2.2 20-03-2019 12:53:24 Page 5/13
Licensee: License No.: 10255062220211WPN5

Reinforcement Reinforcement Preferred Number


Use Type Bar Size of Legs
List List #
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2

Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 13000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
RAPT 6.2.2.2 20-03-2019 12:53:25 Page 6/13
Licensee: License No.: 10255062220211WPN5

Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
Crack Width Calculations List Code default
AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
4 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100
RAPT 6.2.2.2 20-03-2019 12:53:25 Page 7/13
Licensee: License No.: 10255062220211WPN5
Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum
of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 70 0.4 2.7 0.2 0.002 2800
2 23 70 0.4 2.7 0.2 0.002 2800
3 23 70 0.4 2.7 0.2 0.002 2800
4 23 70 0.4 2.7 0.2 0.002 2800

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 13000mm
RAPT 6.2.2.2 20-03-2019 12:53:26 Page 8/13
Licensee: License No.: 10255062220211WPN5
Plan view

mm 1 2
-600

600

1200

1800
0 13000mm

Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 13000mm
Warnings
Input
No errors or warnings were found.

Output
Warning:SPAN Reinforcing Bar spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See Detailed
Reinforcement Design Comments.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 85.3mm - 3 - 4/12.7

1 2
kN
124

118

112
110
106

100
0 13000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 3 - 4/12.7

kN/m 1 2
600

400

200

0
0 -32.9 13000mm
RAPT 6.2.2.2 20-03-2019 12:53:26 Page 9/13
Licensee: License No.: 10255062220211WPN5
Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -90.76 -83.61 -90.76 -83.61 136.38 226.04 130.89
Moment Below kNm -119.37 -109.97 -119.37 -109.97 179.38 297.31 172.16
Reaction kN 0 0 0 0 171.92 260.95 165
Elastic Rotation #.# 0 0 -1.1e-4 -1.01e-4 1.65e-4 2.73e-4 1.58e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Moment Above kNm 90.76 83.61 90.76 83.61 -136.38 -225.25 -130.89
Moment Below kNm 119.37 109.97 119.37 109.97 -179.38 -296.26 -172.16
Reaction kN 0 0 0 0 171.92 257.9 165
Elastic Rotation #.# 0 0 1.1e-4 1.01e-4 -1.65e-4 -2.72e-4 -1.58e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 409.71 409.71 460.03 656.37 460.03 656.37
Moment Below kNm 538.88 538.88 605.07 863.3 605.07 863.3
Reaction kN 597.87 597.87 649.31 896.81 649.31 896.81
Elastic Rotation #.# 4.95e-4 4.95e-4 6.56e-4 8.93e-4 6.56e-4 8.93e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -408.91 -408.91 -655.18 -458.84 -458.84 -655.18
Moment Below kNm -537.84 -537.84 -861.74 -603.5 -603.5 -861.74
Reaction kN 594.82 594.82 892.23 644.73 644.73 892.23
Elastic Rotation #.# -4.94e-4 -4.94e-4 -8.92e-4 -6.55e-4 -6.55e-4 -8.92e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

kNm 1 2
-2000
-1600 -1213 -1212
-1200
-800
-400
0
400
800
1200
1600 1265
0 13000mm

Moment Moment 1 Moment 2

1 2
kN
819
900
600
300
0
-300
-600
-900
-814
0 13000mm

Shear Shear 1 Shear 2


RAPT 6.2.2.2 20-03-2019 12:53:27 Page 10/13
Licensee: License No.: 10255062220211WPN5
Flexural Design
Ultimate

mm2 1 2
1800 1430 1458
1500
1200
900
600
300
0
-300
-600 344
0 13000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot

1 2
kNm
-1600
-1200
-800
-400
0
400
800
1200
1600
0 13000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.305

0.304
0.4
0.3
0.2
0.1
0
-0.1
0.12

-0.2
-0.3
-0.4
0 13000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

1 2
MPa MPa
-4 -2.7 -266.67
-2 -133.33
0 0
2 133.33
4 266.67
6 400
8 533.33
10 666.67
12 800
14 6.42 933.33
0 13000 mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits
RAPT 6.2.2.2 20-03-2019 12:53:28 Page 11/13
Licensee: License No.: 10255062220211WPN5
Reversal Moment Condition

1 2
MPa MPa
-4 -2.7 -266.67
-2 -133.33
0 0
2 133.33
4 266.67
6 400
8 533.33
10 666.67
12 800
14 6.42 933.33
0 13000 mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension Limits

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-3.2 -9.6
-2.4 -7.2
-1.6 -4.8
-0.8 -2.4
0 0 0
0.8 2.4
1.6 4.8
2.4 2.47 7.2
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

1 2
MPa MPa
-1.4
-2 -30
-1 -15
0 0
1 15
2 30
3 45
4 60
5 75
6 90
7 105
4.77
8 120
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

1 2
MPa MPa
-1.4
-2 -30
-1 -15
0 0
1 15
2 30
3 45
4 60
5 75
6 90
7 105
4.77
8 120
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension
RAPT 6.2.2.2 20-03-2019 12:53:28 Page 12/13
Licensee: License No.: 10255062220211WPN5
Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 818.92 -1212.79 561.56 580 1430.07 1060 2.03e5 1144.17 1144.17 2909.85 1.17 85.6 133.6 192.4 Minimum Steel
935 760.72 -770.5 453.79 479.1 310.59 1060 592.12 1149.23 592.12 2403.67 1.17 85.6 133.6 192.4 Minimum Steel
1349 717.69 -464.47 380.58 384.6 0 1060 578.09 1135.01 578.09 1929.38 1.17 85.6 133.6 192.4 Minimum Steel
1763 676.24 -187.89 313.51 333.6 0 1060 1004.14 1121.77 1004.14 1673.66 1.17 85.6 133.6 192.4 Minimum Steel
2177 633.21 83.17 94.87 413.1 0 1060 689.63 1107.55 689.63 2072.41 1.17 85.6 133.6 192.4 Minimum Steel
2591 588.55 346.82 151.08 455.5 0 1060 324.42 1093.9 324.42 2285.31 1.61 62.6 97.7 140.7
3005 547.15 571.84 201.87 493.7 0 1060 309.6 1080.7 309.6 2476.79 1.33 75.4 117.7 169.5
3230 439.95 640.07 227.12 512.7 0 1060 321.48 1073.54 321.48 2571.88 1.17 85.6 133.6 192.4 Minimum Steel
3250 430.59 648.78 229.28 514.3 0 1060 322.5 1072.89 322.5 2580.02 1.17 85.6 133.6 192.4 Minimum Steel
3455 327.29 726.46 250.62 530.3 0 1060 332.58 1066.17 332.58 2660.64 1.17 85.6 133.6 192.4 Minimum Steel
4977 183.91 1036.02 364.41 618.4 68.58 1060 387.8 1013.75 387.8 3102.39 1.17 85.6 133.6 192.4 Minimum Steel
6500 49.89 1113.13 401.16 645.4 344.43 1060 404.73 960.69 404.73 3237.82 1.17 85.6 133.6 192.4 Minimum Steel
7947 -171.44 1056.32 365.34 622 121.32 1060 390.05 1006.51 390.05 3120.37 1.17 85.6 133.6 192.4 Minimum Steel
9395 -307.12 787.64 260.08 541.4 0 1060 339.54 1050.7 339.54 2716.3 1.17 85.6 133.6 192.4 Minimum Steel
9620 -420.5 705.78 237.27 524.6 0 1060 328.97 1056.95 328.97 2631.75 1.17 85.6 133.6 192.4 Minimum Steel
9750 -486.01 646.86 223.29 514.3 0 1060 322.5 1060.44 322.5 2580.02 1.17 85.6 133.6 192.4 Minimum Steel
9845 -530.47 598.57 212.7 506.5 0 1060 317.61 1062.94 317.61 2540.89 1.17 85.6 133.6 192.4 Minimum Steel
10289 -571.5 407.04 159.33 467 0 1060 301.91 1074.6 301.91 2343.02 1.6 62.9 98.1 141.3
10733 -619.28 132.11 99.71 422.7 0 1060 489.32 1086.58 489.32 2120.52 1.17 85.6 133.6 192.4 Minimum Steel
11177 -665.42 -153.09 293.44 326.6 0 1060 1122.78 1099.1 1099.1 1638.37 1.17 85.6 133.6 192.4 Minimum Steel
11621 -709.99 -446.54 364.69 380.7 0 1060 573.18 1112.42 573.18 1910.13 1.17 85.6 133.6 192.4 Minimum Steel
12065 -756.14 -772.02 442.99 470 224.54 1060 572.9 1126.86 572.9 2357.76 1.17 85.6 133.6 192.4 Minimum Steel
12625 -814.34 -1211.75 550.83 580.5 1457.67 1060 2.08e5 1122.29 1122.29 2912.42 1.17 85.6 133.6 192.4 Minimum Steel

1 2
mm
180
160
140
120
100
80
60
40
20
97.7 *
0
0 13000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

kN 1 2
1600
1200 819
800
400
0
-400
-800
-1200 -814
-1600
0 13000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*
RAPT 6.2.2.2 20-03-2019 12:53:29 Page 13/13
Licensee: License No.: 10255062220211WPN5
Deflections
Live Load on All Spans
Transfer

1 2
mm
0
0.439

-9

-18

-27

29473
0 13000mm

Short Term

1 2
mm
0

-9 -5.68

-18

-27

2278
0 13000mm

Incremental

1 2
mm
0

-9
-8.33

-18

-27

1555
0 13000mm

Total Long Term

1 2
mm
0

-9
-11.8
-18

-27

1094
0 13000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 3RD SLAB Date         : 20‐03‐2019

Location  :  3PTB‐1


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 700 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 2110 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 12 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 12 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1185 mm
Effective depth of section with respect to 1st Layer tendon  = 646
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 646.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.046
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.101
xu  = 64.988
Moment resisting capacity of section by Tendons  = 1186 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T20)
Ast  = 2
2286 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 675 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 547 kN‐m
Design Moment at critical section  = 1265 kN‐m
Total Flexural capacity of section  = 1732 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 976500 mm2
Area of flange  = 316500
Area of web  = 660000
Y1  = 75
Y2  = 425
Depth of Neutral axis from top fiber yt  = 311.56
Depth of Neutral axis from bottom fiber yb  = 388.44
Moment of Inertia of T section Ixx  = 43435776210

Section modulas zt  = 1E+08
Section modulas zb  = 1E+08
Eccentricity e  = 334.4 mm

Available tendon force at service (1st Layer)  = 110 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 110.0 kN
Total effective force @ Service P  = 1320 kN
Moment due to self weight  = 211 kN‐m
Moment due to super imposed dead load  = 301 kN‐m
Moment due to Live load  = 202 kN‐m
Secondary Moment  = 194 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 908 kN‐m
Stress due to direct prestress  = P/A
 = 1.35
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 3.17
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 3.95
Stress due to Applied loads @ Top fiber  = M/Zt

 = 6.51
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 8.12

ƒt 2
Stress at extreme top fiber  = 4.70 N/mm
Stress at extreme bottom fiber ƒb  = ‐2.82 N/mm2
Negative sign indicates Tensile stress.
TH
4 SLAB
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN REPORT\4PTB-1-5.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 375
1 13000 150 3600 3600
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 625 1200 1200 3020

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:53:55 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 -375 27.21 2 375 27.21

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 10 2 375 10

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 2.2 2 375 2.2

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 10 2 375 10 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0

Load Combinations : Transfer Prestress


Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0
RAPT 6.2.2.2 20-03-2019 12:53:56 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Pre Existing
Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

1 2
kN/m
40
30 L1
20
10
0
0 13000mm

Load Case 2 : 2. Initial Dead Load

1 2
kN/m
40
30
20
10 P1
0
0 13000mm
40
30
20
L1
10
0
1 2

Load Case 3 : 3. Live Load

1 2
kN/m
40 P1
30
20
10
0
0 13000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 5 4 4 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 13750

Tendon 1 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 4
RAPT 6.2.2.2 20-03-2019 12:53:56 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Allowable Profiles
Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 236.5 236.5 40 236.5 236.5 416.5 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 625 470.7 470.7 54.2 470.7 470.7 416.5 100 110.28 127.8

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 86mm - 4 - 4/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 13375
Height mm 470 460 360 255 170 105 65 45 45 65 105 170 255 360 460 470

Critical Profile Points


Span 1 Locat mm -375 0 384.8 6500 12615.2 13000 13375
Height mm -165.8 -163.1 -186.8 -585 -186.8 -163.1 -165.8

Tendon 1 : - 4 - 4/12.7
mm
0
4

4
-200

-400

-600
470cl

470cl

1 2
460

360

255

170

105

105

170

255

360

460
65

45

45

65

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2
RAPT 6.2.2.2 20-03-2019 12:53:57 Page 5/13
Licensee: License No.: 10255062220211WPN5
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 13000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
RAPT 6.2.2.2 20-03-2019 12:53:58 Page 6/13
Licensee: License No.: 10255062220211WPN5

Crack Width Calculations List Code default


AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
5 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100

Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum


of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 90 0.4 2.7 0.2 0.002 2800
2 23 90 0.4 2.7 0.2 0.002 2800
3 23 90 0.4 2.7 0.2 0.002 2800
4 23 90 0.4 2.7 0.2 0.002 2800
5 23 90 0.4 2.7 0.2 0.002 2800
RAPT 6.2.2.2 20-03-2019 12:53:58 Page 7/13
Licensee: License No.: 10255062220211WPN5
Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 13000mm

Plan view

mm 1 2
-1800

-900

900

1800
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:53:59 Page 8/13
Licensee: License No.: 10255062220211WPN5
Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 13000mm
Warnings
Input
No errors or warnings were found.

Output
No errors or warnings were found.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 86mm - 4 - 4/12.7

1 2
kN
126

117

108 109

99

90
0 13000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 4 - 4/12.7

1 2

kN/m
600

400

200

0
0 -36.5 13000mm

Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -138.33 -125.56 -138.33 -125.56 154.5 101.74 204.38
Moment Below kNm -174.6 -158.48 -174.6 -158.48 195.01 128.41 257.97
Reaction kN 0 0 -0 -0 187.09 123.2 247.5
Elastic Rotation #.# 0 0 -1.67e-4 -1.51e-4 1.86e-4 1.23e-4 2.46e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Moment Above kNm 138.33 125.56 138.33 125.56 -154.5 -101.74 -204.38
Moment Below kNm 174.6 158.48 174.6 158.48 -195.01 -128.41 -257.97
Reaction kN 0 0 -0 -0 187.09 123.2 247.5
Elastic Rotation #.# 0 0 1.67e-4 1.51e-4 -1.86e-4 -1.23e-4 -2.46e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0
RAPT 6.2.2.2 20-03-2019 12:53:59 Page 9/13
Licensee: License No.: 10255062220211WPN5

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 335.06 335.06 258.79 565.36 258.79 565.36
Moment Below kNm 422.91 422.91 326.65 713.6 326.65 713.6
Reaction kN 557.79 557.79 465.44 836.69 465.44 836.69
Elastic Rotation #.# 4.04e-4 4.04e-4 4.63e-4 8.33e-4 4.63e-4 8.33e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -335.06 -335.06 -565.36 -258.79 -258.79 -565.36
Moment Below kNm -422.91 -422.91 -713.6 -326.65 -326.65 -713.6
Reaction kN 557.79 557.79 836.69 465.44 465.44 836.69
Elastic Rotation #.# -4.04e-4 -4.04e-4 -8.33e-4 -4.63e-4 -4.63e-4 -8.33e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

1 2
kNm
-1600
-1200 -999 -999
-800
-400
0
400
800
1200
1600 1283
0 13000mm

Moment Moment 1 Moment 2

1 2
kN
900 745
600
300
0
-300
-600
-900 -745
0 13000mm

Shear Shear 1 Shear 2

Flexural Design
Ultimate

1 2
mm2
600 512 505
500
400
300
200
100
0
-100
-200 0
0 13000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot
RAPT 6.2.2.2 20-03-2019 12:54:00 Page 10/13
Licensee: License No.: 10255062220211WPN5

1 2
kNm
-1200
-800
-400
0
400
800
1200
1600
0 13000mm

Capacity Minimum Ultimate Design Initial Final

1 2

0.379
0.6
0.38

0.4
0.2
0

0.117
-0.2
-0.4

0 13000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

MPa 1 2 MPa
-4 -2.19 -60
-2 -30
0 0
2 30
4 60
6 90
8 120
6.4
10 150
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

Reversal Moment Condition

MPa 1 2 MPa
-4 -2.19 -60
-2 -30
0 0
2 30
4 60
6 90
8 120
6.4
10 150
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.
RAPT 6.2.2.2 20-03-2019 12:54:01 Page 11/13
Licensee: License No.: 10255062220211WPN5
Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-4 -12
-3 -9
-2 -6
-1 -3
0 0 0
1 3
2 6
3 3.01 9
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

MPa 1 2 MPa
-0.5 0 -3
0 0
0.5 3
1 6
1.5 9
2 12
2.5 15
3 18
3.5 21
4 3.44 24
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

MPa 1 2 MPa
-0.5 0 -3
0 0
0.5 3
1 6
1.5 9
2 12
2.5 15
3 18
3.5 21
4 3.44 24
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 745.49 -999.7 661.02 470.1 461.35 960 1.41e5 1050.15 1050.15 2136.06 1.06 94.5 147.5 212.4 Minimum Steel
875 684.64 -642.17 553.66 425.9 512.24 960 699.12 1031.44 699.12 1935.02 1.06 94.5 147.5 212.4 Minimum Steel
1350 626.83 -330.69 459.63 330.9 0 960 801.15 1012.87 801.15 1503.6 1.06 94.5 147.5 212.4 Minimum Steel
1825 571.24 -62.85 373.76 282.2 0 960 2815.2 994.26 994.26 1282.36 1.06 94.5 147.5 211.7 Minimum Steel
2300 511.14 210 124.91 386.7 0 960 354.38 976.06 354.38 1757.17 1.12 89.6 139.8 201.2
2775 453.33 439.06 193.57 426 0 960 277.45 958.13 277.45 1935.63 1.14 87.9 137.2 197.5
3250 407.91 566.83 254.05 460.6 0 960 270.1 940.34 270.1 2092.69 1.06 94.5 147.5 212.4 Minimum Steel
4333 276.1 937.22 361.15 521.8 0 960 296.35 899.91 296.35 2370.81 1.06 94.5 147.5 212.4 Minimum Steel
5416 166.29 1074.46 425.17 558.5 0 960 317.21 859.25 317.21 2537.72 1.06 94.5 147.5 212.4 Minimum Steel
6500 70.67 1061.68 445.93 570.8 0 960 324.18 818.19 324.18 2593.43 1.06 94.5 147.5 212.4 Minimum Steel
7583 -166.16 1074.62 423.29 558.6 0 960 317.23 856.42 317.23 2537.82 1.06 94.5 147.5 212.4 Minimum Steel
8666 -275.98 937.5 357.38 521.8 0 960 296.38 893.36 296.38 2371.01 1.06 94.5 147.5 212.4 Minimum Steel
9750 -407.91 566.83 248.27 460.6 0 960 268.29 929.16 268.29 2092.69 1.06 94.5 147.5 212.4 Minimum Steel
RAPT 6.2.2.2 20-03-2019 12:54:01 Page 12/13
Licensee: License No.: 10255062220211WPN5

Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
10225 -453.33 439.06 186.95 426 0 960 273.7 944.61 273.7 1935.63 1.17 86.1 134.4 193.4
10700 -511.14 210 117.44 386.7 0 960 341.7 960.03 341.7 1757.17 1.21 82.9 129.3 186.2
11175 -571.24 -62.85 361.22 282.2 0 960 2725.82 975.54 975.54 1282.36 1.06 94.5 147.5 211.7 Minimum Steel
11650 -626.83 -330.69 445.81 330.9 0 960 782.27 991.28 782.27 1503.6 1.06 94.5 147.5 212.4 Minimum Steel
12125 -684.64 -642.17 538.96 420.3 424.17 960 682.8 1007.44 682.8 1909.44 1.06 94.5 147.5 212.4 Minimum Steel
12625 -745.49 -999.7 646.36 471.9 504.7 960 1.46e5 1025.15 1025.15 2143.98 1.06 94.5 147.5 212.4 Minimum Steel

mm 1 2
210
180
150
120
90
60
30
129 *
0
0 13000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

1 2
kN
1200
745
800
400
0
-400
-800
-745
-1200
0 13000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

1 2
mm
0
0.998

-7

-14

-21
12899
0 13000mm

Short Term

1 2
mm
0

-7 -5.15

-14

-21
2501
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:54:02 Page 13/13
Licensee: License No.: 10255062220211WPN5
Incremental

1 2
mm
0

-7
-7.79
-14

-21
1653
0 13000mm

Total Long Term

1 2
mm
0

-7
-9.16
-14

-21
1405
0 13000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 4TH SLAB Date         : 20‐03‐2019

Location  :  4PTB:1‐5


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 625 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 3020 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 16 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 16 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1579 mm
Effective depth of section with respect to 1st Layer tendon  = 571
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 571.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.049
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.106
xu  = 60.571
Moment resisting capacity of section by Tendons  = 1394 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T20)
Ast  = 2
2286 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 600 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 488 kN‐m
Design Moment at critical section  = 1283 kN‐m
Total Flexural capacity of section  = 1882 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 1E+06 mm2
Area of flange  = 453000
Area of web  = 570000
Y1  = 75
Y2  = 387.5
Depth of Neutral axis from top fiber yt  = 249.12
Depth of Neutral axis from bottom fiber yb  = 375.88
Moment of Inertia of T section Ixx  = 36215458211

Section modulas zt  = 1E+08
Section modulas zb  = 1E+08
Eccentricity e  = 321.9 mm

Available tendon force at service (1st Layer)  = 109 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 109.0 kN
Total effective force @ Service P  = 1744 kN
Moment due to self weight  = 223 kN‐m
Moment due to super imposed dead load  = 147 kN‐m
Moment due to Live load  = 296 kN‐m
Secondary Moment  = 284 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 950 kN‐m
Stress due to direct prestress  = P/A
 = 1.70
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 3.86
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 5.83
Stress due to Applied loads @ Top fiber  = M/Zt

 = 6.53
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 9.86

ƒt 2
Stress at extreme top fiber  = 4.38 N/mm
Stress at extreme bottom fiber ƒb  = ‐2.33 N/mm2
Negative sign indicates Tensile stress.
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN
REPORT\4PTB-10,12,14,16,18,19.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 375
1 14000 150 3600 3600
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3600 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 650 1200 1200 3160

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:54:35 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 -375 27.95 2 375 27.95

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 10 2 375 10

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 2.2 2 375 2.2

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 10 2 375 10 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0

Load Combinations : Transfer Prestress


Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0
RAPT 6.2.2.2 20-03-2019 12:54:36 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Pre Existing
Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

1 2
kN/m
40
30 L1
20
10
0
0 14000mm

Load Case 2 : 2. Initial Dead Load

1 2
kN/m
40
30
20
10 P1
0
0 14000mm
40
30
20
L1
10
0
1 2

Load Case 3 : 3. Live Load

1 2
kN/m
40 P1
30
20
10
0
0 14000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 5 5 3.6 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 14750

Tendon 1 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 5
RAPT 6.2.2.2 20-03-2019 12:54:37 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Allowable Profiles
Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 244 244 40 244 244 441 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 650 495.2 495.2 54.2 495.2 495.2 441 100 110.95 128.6

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 92.7mm - 3.6 - 5/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 14375
Height mm 495 485 390 280 195 125 80 50 40 50 80 125 195 280 390 485 495

Critical Profile Points


Span 1 Locat mm -375 0 378.4 7000 13621.6 14000 14375
Height mm -166.3 -163.6 -186.4 -610 -186.4 -163.6 -166.3

Tendon 1 : - 3.6 - 5/12.7


mm
0
5

5
-200

-400

-600
495cl

495cl

1 2
485

390

280

195

125

125

195

280

390

485
80

50

40

50

80

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2
RAPT 6.2.2.2 20-03-2019 12:54:37 Page 5/13
Licensee: License No.: 10255062220211WPN5
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 14000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
RAPT 6.2.2.2 20-03-2019 12:54:38 Page 6/13
Licensee: License No.: 10255062220211WPN5

Crack Width Calculations List Code default


AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
5 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100

Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum


of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 90 0.4 2.7 0.2 0.002 2800
2 23 90 0.4 2.7 0.2 0.002 2800
3 23 90 0.4 2.7 0.2 0.002 2800
4 23 90 0.4 2.7 0.2 0.002 2800
5 23 90 0.4 2.7 0.2 0.002 2800
RAPT 6.2.2.2 20-03-2019 12:54:38 Page 7/13
Licensee: License No.: 10255062220211WPN5
Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 14000mm

Plan view

mm 1 2
-1800

-900

900

1800
0 14000mm
RAPT 6.2.2.2 20-03-2019 12:54:39 Page 8/13
Licensee: License No.: 10255062220211WPN5
Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 14000mm
Warnings
Input
No errors or warnings were found.

Output
No errors or warnings were found.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 92.7mm - 3.6 - 5/12.7

1 2
kN
126

117

108 110

99

90
0 14000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 3.6 - 5/12.7

1 2
kN/m
800

600

400

200

0
0 -37.5 14000mm

Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -163.15 -147.84 -163.15 -147.84 182.27 116.87 234.78
Moment Below kNm -208.69 -189.11 -208.69 -189.11 233.15 149.49 300.31
Reaction kN 0 0 -0 -0 206.12 132.16 265.5
Elastic Rotation #.# 0 0 -1.9e-4 -1.72e-4 2.13e-4 1.36e-4 2.74e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live Load
Transfer Service Transfer Service Weight Dead
Load
Moment Above kNm 163.15 147.84 163.15 147.84 -182.27 -116.87 -234.78
Moment Below kNm 208.69 189.11 208.69 189.11 -233.15 -149.49 -300.31
Reaction kN 0 0 -0 -0 206.12 132.16 265.5
Elastic Rotation #.# 0 0 1.9e-4 1.72e-4 -2.13e-4 -1.36e-4 -2.74e-4
Elastic Axial Shortening mm 0 0 0 0 0 0 0
RAPT 6.2.2.2 20-03-2019 12:54:40 Page 9/13
Licensee: License No.: 10255062220211WPN5

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 386.07 386.07 300.87 653.03 300.87 653.03
Moment Below kNm 493.84 493.84 384.85 835.32 384.85 835.32
Reaction kN 603.78 603.78 507.43 905.68 507.43 905.68
Elastic Rotation #.# 4.5e-4 4.5e-4 5.23e-4 9.34e-4 5.23e-4 9.34e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -386.07 -386.07 -653.03 -300.87 -300.87 -653.03
Moment Below kNm -493.84 -493.84 -835.32 -384.85 -384.85 -835.32
Reaction kN 603.78 603.78 905.68 507.43 507.43 905.68
Elastic Rotation #.# -4.5e-4 -4.5e-4 -9.34e-4 -5.23e-4 -5.23e-4 -9.34e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

kNm 1 2
-2000
-1500 -1183 -1183
-1000
-500
0
500
1000
1500
2000 1512
0 14000mm

Moment Moment 1 Moment 2

kN 1 2
1200
814
900
600
300
0
-300
-600
-900
-814
-1200
0 14000mm

Shear Shear 1 Shear 2

Flexural Design
Ultimate

1 2
mm2
687 731
800
600
400
200
0
-200
0
0 14000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot
RAPT 6.2.2.2 20-03-2019 12:54:40 Page 10/13
Licensee: License No.: 10255062220211WPN5

1 2
kNm
-1600
-1200
-800
-400
0
400
800
1200
1600
2000
0 14000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.406

0.404
0.6
0.4
0.2
0
-0.2

0.121
-0.4

0 14000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

MPa 1 2 MPa
-4 -2.3 -40
-2 -20
0 0
2 20
4 40
6 60
8 80
10 6.84 100
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

Reversal Moment Condition

MPa 1 2 MPa
-4 -2.3 -40
-2 -20
0 0
2 20
4 40
6 60
8 80
10 6.84 100
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Limits Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.
RAPT 6.2.2.2 20-03-2019 12:54:41 Page 11/13
Licensee: License No.: 10255062220211WPN5
Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-4 -12
-3 -9
-2 -6
-1 -3
0 0 0
1 3
2 6
3 9
3.24
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

1 2
MPa MPa
-5 -5
-4 -4
-3 -3
-2 -2
-1 -1
0 0 0
1 1
2 2
3 3
4 3.67 4
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

1 2
MPa MPa
-5 -5
-4 -4
-3 -3
-2 -2
-1 -1
0 0 0
1 1
2 2
3 3
4 3.67 4
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 3 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 2.13MPa.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 813.64 -1183.53 790.75 500.5 686.64 984 1.61e5 1144.93 1144.93 2330.93 1.09 92.2 143.9 207.2 Minimum Steel
895 749.78 -777.04 666.72 445.9 513.11 984 760.7 1124.99 760.7 2076.52 1.09 92.2 143.9 207.2 Minimum Steel
1416 685.8 -403.07 553.13 349.7 0 984 865.6 1105.78 865.6 1628.69 1.09 92.2 143.9 207.2 Minimum Steel
1937 624.24 -81.44 449.16 297.2 0 984 2859.61 1085.75 1085.75 1383.86 1.09 92.2 143.9 207.2 Minimum Steel
2458 557.77 245 143.98 400.3 0 984 381.47 1065.29 381.47 1864.13 1.22 82.4 128.6 185.2
2979 493.79 518.93 227.39 442.6 0 984 300.6 1045.14 300.6 2061.04 1.21 83.2 129.8 186.8
3500 443.2 673.34 300.71 479.7 0 984 292.88 1025.17 292.88 2234 1.09 92.2 143.9 207.2 Minimum Steel
4666 300.01 1106.63 428.02 544.2 0 984 316.78 980.61 316.78 2534.25 1.09 92.2 143.9 207.2 Minimum Steel
5832 180.54 1267.68 504.15 582.9 0 984 339.31 935.74 339.31 2714.48 1.09 92.2 143.9 207.2 Minimum Steel
7000 76.22 1253.42 528.86 595.8 0 984 346.84 890.35 346.84 2774.69 1.09 92.2 143.9 207.2 Minimum Steel
8166 -180.29 1268.04 501.97 582.9 0 984 339.34 932.51 339.34 2714.68 1.09 92.2 143.9 207.2 Minimum Steel
9332 -299.76 1107.23 423.66 544.3 0 984 316.83 973.2 316.83 2534.66 1.09 92.2 143.9 207.2 Minimum Steel
10500 -443.2 673.34 293.9 479.7 0 984 290.74 1012.6 290.74 2234 1.09 92.2 143.9 207.2 Minimum Steel
RAPT 6.2.2.2 20-03-2019 12:54:41 Page 12/13
Licensee: License No.: 10255062220211WPN5

Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
11021 -493.79 518.93 219.56 442.6 0 984 296.32 1029.9 296.32 2061.04 1.24 81.4 127 182.8
11542 -557.77 245 135.14 400.3 0 984 367.2 1047.16 367.2 1864.13 1.32 76.3 119 171.3
12063 -624.24 -81.44 434.04 297.2 0 984 2768.73 1064.55 1064.55 1383.86 1.09 92.2 143.9 207.2 Minimum Steel
12584 -685.8 -403.07 537.09 349.7 0 984 845.87 1082.23 845.87 1628.69 1.09 92.2 143.9 207.2 Minimum Steel
13105 -749.78 -777.04 650.71 439.9 414.6 984 743.61 1100.43 743.61 2048.65 1.09 92.2 143.9 207.2 Minimum Steel
13625 -813.64 -1183.53 774.78 501.9 731.46 984 1.66e5 1119.38 1119.38 2337.46 1.09 92.2 143.9 207.2 Minimum Steel

1 2
mm
200
180
160
140
120
100
80
60
40
20
119 *
0
0 14000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

kN 1 2
1600
1200 814
800
400
0
-400
-800
-1200 -814
-1600
0 14000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

1 2
mm
0
1.21

-9

-18

-27
11500
0 14000mm

Short Term

1 2
mm
0

-9 -6.09

-18

-27
2282
0 14000mm
RAPT 6.2.2.2 20-03-2019 12:54:42 Page 13/13
Licensee: License No.: 10255062220211WPN5
Incremental

1 2
mm
0

-9
-9.21
-18

-27
1509
0 14000mm

Total Long Term

1 2
mm
0

-9
-10.8
-18

-27
1284
0 14000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 4TH SLAB Date         : 20‐03‐2019

Location  :  4PTB:10,12,14,16,18,19


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 650 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 3160 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 18 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 18 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1777 mm
Effective depth of section with respect to 1st Layer tendon  = 596
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 596.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.050
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.109
xu  = 65.138
Moment resisting capacity of section by Tendons  = 1635 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T20)
Ast  = 2
2286 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 625 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 509 kN‐m
Design Moment at critical section  = 1512 kN‐m
Total Flexural capacity of section  = 2144 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 1E+06 mm2
Area of flange  = 474000
Area of web  = 600000
Y1  = 75
Y2  = 400
Depth of Neutral axis from top fiber yt  = 256.56
Depth of Neutral axis from bottom fiber yb  = 393.44
Moment of Inertia of T section Ixx  = 41358722067

Section modulas zt  = 2E+08
Section modulas zb  = 1E+08
Eccentricity e  = 339.4 mm

Available tendon force at service (1st Layer)  = 110 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 110.0 kN
Total effective force @ Service P  = 1980 kN
Moment due to self weight  = 267 kN‐m
Moment due to super imposed dead load  = 171 kN‐m
Moment due to Live load  = 344 kN‐m
Secondary Moment  = 337 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 1119 kN‐m
Stress due to direct prestress  = P/A
 = 1.84
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 4.17
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 6.39
Stress due to Applied loads @ Top fiber  = M/Zt

 = 6.94
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 10.64

ƒt 2
Stress at extreme top fiber  = 4.62 N/mm
Stress at extreme bottom fiber ƒb  = ‐2.41 N/mm2
Negative sign indicates Tensile stress.
TH
5 SLAB
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN REPORT\5PTB-1-10.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 375
1 13000 150 3800 3800
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3800 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3800 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 600 1200 1200 3020

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:55:46 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load at Right End Right end of Load at Description
Reference load from left end reference load from right
Column reference column reference end
column column
mm kN/m mm kN/m A
1 1 -375 27.21 2 375 27.21

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 10 2 375 10

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 3.4 2 375 3.4

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 1.5 2 375 1.5 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0

Load Combinations : Transfer Prestress


Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0
RAPT 6.2.2.2 20-03-2019 12:55:47 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Pre Existing
Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

kN/m 1 2
32 L1
24
16
8
0
0 13000mm

Load Case 2 : 2. Initial Dead Load

kN/m 1 2
32
24
16 P1
8
0
0 13000mm
32
24
16 L1
8
0
1 2

Load Case 3 : 3. Live Load

kN/m 1 2
32
24
16
8 P1
0
0 13000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 5 3 4 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 13750

Tendon 1 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 3
RAPT 6.2.2.2 20-03-2019 12:55:47 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Allowable Profiles
Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 225.6 225.6 40 225.6 225.6 392 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 600 446.2 446.2 54.2 446.2 446.2 392 100 110.24 90.2

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 86.4mm - 4 - 3/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 13375
Height mm 445 435 340 240 160 100 60 40 40 60 100 160 240 340 435 445

Critical Profile Points


Span 1 Locat mm -375 0 363.7 6500 12636.3 13000 13375
Height mm -165.3 -162.6 -183.6 -560 -183.6 -162.6 -165.3

Tendon 1 : - 4 - 3/12.7
mm
0
3

3
-200

-400

-600
445cl

445cl

1 2
435

340

240

160

100

100

160

240

340

435
60

40

40

60

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2
RAPT 6.2.2.2 20-03-2019 12:55:48 Page 5/13
Licensee: License No.: 10255062220211WPN5
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600
0 13000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
RAPT 6.2.2.2 20-03-2019 12:55:49 Page 6/13
Licensee: License No.: 10255062220211WPN5

Crack Width Calculations List Code default


AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
5 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100

Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum


of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 90 0.4 2.7 0.2 0.002 2800
2 23 90 0.4 2.7 0.2 0.002 2800
3 23 90 0.4 2.7 0.2 0.002 2800
4 23 90 0.4 2.7 0.2 0.002 2800
5 23 90 0.4 2.7 0.2 0.002 2800
RAPT 6.2.2.2 20-03-2019 12:55:49 Page 7/13
Licensee: License No.: 10255062220211WPN5
Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600
0 13000mm

Plan view

mm 1 2
-1800

-900

900

1800
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:55:50 Page 8/13
Licensee: License No.: 10255062220211WPN5
Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 13000mm
Warnings
Input
No errors or warnings were found.

Output
No errors or warnings were found.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 86.4mm - 4 - 3/12.7

1 2
kN
128

121

114

111
107

100
0 13000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 4 - 3/12.7

1 2

kN/m
500

400

300

200

100

0
0 -26 13000mm

Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -102.24 -93.44 -102.24 -93.44 156.23 131.58 32.72
Moment Below kNm -127.39 -116.42 -127.39 -116.42 194.65 163.94 40.77
Reaction kN 0 0 0 0 187.09 157.57 39.19
Elastic Rotation #.# 0 0 -1.31e-4 -1.2e-4 2.01e-4 1.69e-4 0
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live


Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm 102.24 93.44 102.24 93.44 -156.23 -131.58 -32.72
Moment Below kNm 127.39 116.42 127.39 116.42 -194.65 -163.94 -40.77
Reaction kN 0 0 -0 -0 187.09 157.57 39.19
Elastic Rotation #.# 0 0 1.31e-4 1.2e-4 -2.01e-4 -1.69e-4 0
Elastic Axial Shortening mm 0 0 0 0 0 0 0
RAPT 6.2.2.2 20-03-2019 12:55:50 Page 9/13
Licensee: License No.: 10255062220211WPN5

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 227.09 227.09 243.46 387.36 243.46 387.36
Moment Below kNm 282.95 282.95 303.33 482.63 303.33 482.63
Reaction kN 383.85 383.85 403.45 575.78 403.45 575.78
Elastic Rotation #.# 2.92e-4 2.92e-4 4.33e-4 6.18e-4 4.33e-4 6.18e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -227.09 -227.09 -387.36 -243.46 -243.46 -387.36
Moment Below kNm -282.95 -282.95 -482.63 -303.33 -303.33 -482.63
Reaction kN 383.85 383.85 575.78 403.45 403.45 575.78
Elastic Rotation #.# -2.92e-4 -2.92e-4 -6.18e-4 -4.33e-4 -4.33e-4 -6.18e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

kNm 1 2
-1200
-900 -678 -678
-600
-300
0
300
600
900
893
1200
0 13000mm

Moment Moment 1 Moment 2

1 2
kN
600 513
400
200
0
-200
-400
-600 -513
0 13000mm

Shear Shear 1 Shear 2

Flexural Design
Ultimate

1 2
mm2
548 454
600
500
400
300
200
100
0
-100
-200 0
0 13000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot
RAPT 6.2.2.2 20-03-2019 12:55:51 Page 10/13
Licensee: License No.: 10255062220211WPN5

1 2
kNm
-900
-600
-300
0
300
600
900
1200
0 13000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.325

0.319
0.5
0.4
0.3
0.2
0.1
0
-0.1

0.092
-0.2
-0.3
0 13000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

1 2
MPa MPa
-1.49
-2 -20
-1 -10
0 0
1 10
2 20
3 30
4 40
5 50
6 60
4.77
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

1 2
MPa MPa
-1.49
-2 -20
-1 -10
0 0
1 10
2 20
3 30
4 40
5 50
6 60
4.77
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 2 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 0.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.
RAPT 6.2.2.2 20-03-2019 12:55:51 Page 11/13
Licensee: License No.: 10255062220211WPN5
Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-1.2 -1.2
-0.8 -0.8
-0.4 -0.4
0 0
0.4 0.4
0.8 0.8
1.2 0 1.2
1.6 1.7 1.6
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

1 2
MPa MPa
-1.8 -1.1 -12
-0.9 -6
0 0
0.9 6
1.8 12
2.7 18
3.6 24
4.5 30
5.4 4.26 36
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

1 2
MPa MPa
-1.8 -1.1 -12
-0.9 -6
0 0
0.9 6
1.8 12
2.7 18
3.6 24
4.5 30
5.4 4.26 36
0 13000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 2 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 0.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 512.98 -677.67 473.93 455.4 547.55 960 1.32e5 905.52 905.52 2069.02 1.06 94.5 147.5 212.4 Minimum Steel
855 472.78 -441.09 399.84 366.1 0 960 493.41 891.63 493.41 1663.19 1.06 94.5 147.5 212.4 Minimum Steel
1334 432.66 -224.23 331.67 315.4 0 960 604.75 877.53 604.75 1432.93 1.06 94.5 147.5 212.4 Minimum Steel
1813 392.89 -29.11 269.88 269.2 0 960 3000.69 864.19 864.19 1223.07 1.06 94.5 147.5 201.9 Minimum Steel
2292 352.78 149.48 89.04 372.5 0 960 267.53 851.35 267.53 1692.48 1.06 94.5 147.5 212.4 Minimum Steel
2771 312.66 308.85 138.51 409.7 0 960 232.69 838.84 232.69 1861.53 1.06 94.5 147.5 212.4 Minimum Steel
3250 274.13 439.47 182.1 442.4 0 960 251.27 826.49 251.27 2010.17 1.06 94.5 147.5 212.4 Minimum Steel
4333 183.43 687.24 258.74 499.8 0 960 283.88 798.59 283.88 2271.03 1.06 94.5 147.5 212.4 Minimum Steel
5416 96.2 822.54 304.25 534.3 0 960 303.45 769.49 303.45 2427.59 1.06 94.5 147.5 212.4 Minimum Steel
6500 -11.16 858.45 318.85 545.8 0 960 309.98 739.95 309.98 2479.84 1.06 94.5 147.5 212.4 Minimum Steel
7583 -96.12 822.64 302.93 534.3 0 960 303.46 767.36 303.46 2427.69 1.06 94.5 147.5 212.4 Minimum Steel
8666 -183.35 687.42 256.16 499.9 0 960 283.9 793.79 283.9 2271.23 1.06 94.5 147.5 212.4 Minimum Steel
9750 -274.13 439.47 178.14 442.4 0 960 251.27 818.38 251.27 2010.17 1.06 94.5 147.5 212.4 Minimum Steel
RAPT 6.2.2.2 20-03-2019 12:55:52 Page 12/13
Licensee: License No.: 10255062220211WPN5

Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
10229 -312.66 308.85 133.96 409.7 0 960 232.69 829.05 232.69 1861.53 1.06 94.5 147.5 212.4 Minimum Steel
10708 -352.78 149.48 83.9 372.5 0 960 259.08 839.75 259.08 1692.48 1.06 94.5 147.5 212.4 Minimum Steel
11187 -392.89 -29.11 261.19 269.2 0 960 2908.09 850.66 850.66 1223.07 1.06 94.5 147.5 201.9 Minimum Steel
11666 -432.66 -224.23 322.09 315.4 0 960 591.42 861.96 591.42 1432.93 1.06 94.5 147.5 212.4 Minimum Steel
12145 -472.78 -441.09 389.37 366.1 0 960 486.82 873.9 486.82 1663.19 1.06 94.5 147.5 212.4 Minimum Steel
12625 -512.98 -677.67 463.31 451.2 453.63 960 1.31e5 886.81 886.81 2049.84 1.06 94.5 147.5 212.4 Minimum Steel

mm 1 2
210
180
150
120
90
60
30
148 *
0
0 13000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

1 2
kN
1200
900
513
600
300
0
-300
-600
-513
-900
-1200
0 13000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

mm 1 2
0
-0.274
-6

-12

-18

-24
46961
0 13000mm

Short Term

mm 1 2
0

-6 -3.84

-12

-18

-24
3342
0 13000mm
RAPT 6.2.2.2 20-03-2019 12:55:53 Page 13/13
Licensee: License No.: 10255062220211WPN5
Incremental

mm 1 2
0

-6
-6.09
-12

-18

-24
2111
0 13000mm

Total Long Term

mm 1 2
0

-6

-12 -9.26

-18

-24
1387
0 13000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 5TH SLAB Date         : 20‐03‐2019

Location  :  5PTB: 1 ‐ 10


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 600 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 3020 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 12 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 12 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1185 mm
Effective depth of section with respect to 1st Layer tendon  = 546
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 546.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.038
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.083
xu  = 45.311
Moment resisting capacity of section by Tendons  = 1010 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T16)
Ast  = 2
2060 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 575 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 422 kN‐m
Design Moment at critical section  = 893 kN‐m
Total Flexural capacity of section  = 1432 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 993000 mm2
Area of flange  = 453000
Area of web  = 540000
Y1  = 75
Y2  = 375
Depth of Neutral axis from top fiber yt  = 238.14
Depth of Neutral axis from bottom fiber yb  = 361.86
Moment of Inertia of T section Ixx  = 32132871979

Section modulas zt  = 1E+08
Section modulas zb  = 9E+07
Eccentricity e  = 307.9 mm

Available tendon force at service (1st Layer)  = 111 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 111.0 kN
Total effective force @ Service P  = 1332 kN
Moment due to self weight  = 222 kN‐m
Moment due to super imposed dead load  = 187 kN‐m
Moment due to Live load  = 46.5 kN‐m
Secondary Moment  = 210 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 665.5 kN‐m
Stress due to direct prestress  = P/A
 = 1.34
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 3.04
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 4.62
Stress due to Applied loads @ Top fiber  = M/Zt

 = 4.93
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 7.49

ƒt 2
Stress at extreme top fiber  = 3.23 N/mm
Stress at extreme bottom fiber ƒb  = ‐1.54 N/mm2
Negative sign indicates Tensile stress.
\\radhika\Radhika Share\FROM Nagendra\FOR PT(HAL TESTRIG)\DESIGNS\DESIGN
REPORT\5PTB-11,12,13,15,17,19,20.rpf

RAPT - Version: 6.2.2.2


Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2010 PCDC Pty. Ltd. All Rights Reserved

Licensee
Utracon Structural Systems Pvt Ltd
31 Besant Avenue
Adyar, Chennai - 600020
Tamilnadu India
10255062220211WPN5

Input
General
Design Code List India - BS 8110*SAVED*
Material List India - USSI default Indian Material*SAVED*
Reinforcement Type List Bonded Post-Tensioned
Member Type List Beam
Panel Type List Internal
Strip Type List One way - Nominal Width
Column Stiffness List Equivalent Column
Concrete - Spanning Members List 35MPa
Concrete - Columns List 35MPa
Top Reinforcement Cover mm 65
Bottom Reinforcement Cover mm 50
Self Weight Definition List Program Calculated
Pattern Live Load Y/N
Earthquake Design List None
Moment Redistribution % 0
Design Surface Levels List Extreme Surfaces

Span
Span Span Slab Panel Panel
Length Depth Width Width
Left Right
mm mm mm mm
LE 375
1 14000 180 3800 3800
RE 375

Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column Punching
Grid Type Height Width Length Height Width Length Column below Base Column frame Shortening Shear
Reference Above Above Above below below below spacing deepest below Stiffness at this Restrained Check
section column required
A List mm mm mm mm mm mm mm mm Y/N % Y/N Y/N Y/N
1 1 Column 4000 600 750 4000 600 750 3800 0 N 100 Y Y N
2 2 Column 4000 600 750 4000 600 750 3800 0 N 100 Y Y N

Beams
Beam Beam Beam Beam Effective
Number Depth Width Width Flange
at Width
Slab
mm mm mm mm
1 650 1200 1200 3160

Load Cases
Load Load Type Load Definition Live Load Description
Case Deflection
Case
List List Y/N A
1 Self Weight Applied Loads
2 Initial Dead Load Applied Loads
3 Live Load Applied Loads Y
RAPT 6.2.2.2 20-03-2019 12:56:35 Page 2/13
Licensee: License No.: 10255062220211WPN5
1. Self Weight - Line
Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 30.6 2 375 30.6

2. Initial Dead Load - Line


Load Left End Left end of Load Right End Right end of Load Description
Reference load from at left reference load from at right
Column reference end column reference end
column column
mm kN/m mm kN/m A
1 1 -375 10 2 375 10

2. Initial Dead Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Description
reference load from left end reference load from right
column reference column reference end
column column
mm kN/m2 mm kN/m2 A
1 1 -375 3.4 2 375 3.4

3. Live Load - Panel


Load Left End Left end of Load at Right End Right end of Load at Live Load Description
reference load from left end reference load from right reduction
column reference column reference end
column column
mm kN/m2 mm kN/m2 #.# A
1 1 -375 1.5 2 375 1.5 1

Load Combinations : Ultimate


Load Description Prestress Prestress 1. Self 2. Initial 3.
Combination Secondary Secondary Weight Dead Live
Adverse Beneficial Load Load
A #.# #.# #.# #.# #.#
1 Live Load 1 1 1.5 1.5 1.5
2 Live Load 1 1 1 1 1.5
3 Dead Load 1 1 1.5 1.5 0

Load Combinations : Short Term Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 1

Load Combinations : Permanent Service


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Live Load 1 1 1 0.25

Load Combinations : Deflection


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Short Term - Deflection 1 1 1 1
2 Permanent - Deflection 1 1 1 0.25
3 Initial - Deflection 1 1 1 0

Load Combinations : Transfer Prestress


Load Description Transfer 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Transfer 1 1 0 0
RAPT 6.2.2.2 20-03-2019 12:56:36 Page 3/13
Licensee: License No.: 10255062220211WPN5
Load Combinations : Pre Existing
Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Pre Existing 1 1 0 0

Load Combinations : Construction


Load Description Long-term 1. Self 2. Initial 3.
Combination Prestress Weight Dead Live
Load Load
A #.# #.# #.# #.#
1 Construction 1 1 0 0

Load Case 1 : 1. Self Weight

kN/m 1 2
36 L1
27
18
9
0
0 14000mm

Load Case 2 : 2. Initial Dead Load

kN/m 1 2
36
27
18 P1
9
0
0 14000mm
36
27
18 L1
9
0
1 2

Load Case 3 : 3. Live Load

kN/m 1 2
36
27
18
9 P1
0
0 14000mm
Prestress
Tendon Normal or Steel Steel Prestress
Prestress Number Number Spacing Top Bottom Left Distance to Left
upside down Type Diameter Type Anchorage of of of Cover Cover Anchorage left Anchorage
profiles Size Strands Tendons tendons to to Duct Reference anchorage Type
Duct Column from column
List List List List List List #.# mm mm mm mm List
1 Strand 12.7mm MonoStrand 4 4 4 50 40 1 -375

Tendon Right Distance to Right Stacked tendons, Tendon


Anchorage Right Anchorage No effect on Length
Reference Anchorage from Type effective shear
Column Column width
mm List List mm
1 3 0 Individual 14750

Tendon 1 : - Drape Locations


Span Tendon Length of Left End Length of Right End Reverse Number of Extra Tendon Number of
Profile Type Straight Straight Curve strands angle Profile strands
Section/Start of Section/End of Radius from right change Point full length
Drape Section in Drape Section in terminating in this Spacing of tendon
Span Span in span span in span
List mm mm mm # #.# mm #
1 0 0 2800 0 0 1000 4
RAPT 6.2.2.2 20-03-2019 12:56:36 Page 4/13
Licensee: License No.: 10255062220211WPN5
Tendon 1 : - Allowable Profiles
Span Tendon Cover Tendon Cover Tendon Cover to Tendon Cover Tendon Cover Available Relative
to centreline at to duct at left duct at low point to duct at right to duct at right Parabola Minimum
left end of span end of Parabola of parabola end of Parabola end of span Drape Tendon
Ratio
mm mm mm mm mm mm #.#
1 239.2 239.2 40 239.2 239.2 445.8 1

Tendon 1 : - Adopted Profiles


Span Profile Profile Profile Profile Profile Profile Adopted Percentage of Prestress Balanced
Height height at height at Height at height at height at Parabolic available Force Uniform
Datum left end left end of midpoint of right end of right end Drape parabolic drape Load
of span parabola parabola parabola of span adopted
mm mm mm mm mm mm mm % kN %
1 650 500 500 54.2 500 500 445.8 100 111.39 106

Tendon 1 : - Details
Reverse Curve at Left Anchorage Y/N N
Reverse Curve at Right Anchorage Y/N N
Percentage Jacking Force % 75

Tendon 1 : - Jacking Sequence


Stage Proportion of Stressing Concrete
Jacking force Time in Strength
applied at this days
stage
% #.# MPa
25 0.677 9
75 5.088 25
0 0 0
0 0 0

Tendon 1 : - Gross Extension: 92.7mm - 4 - 4/12.7


Profile Heights
Span 1 Locat mm -375 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000 14375
Height mm 500 490 390 285 195 130 80 50 40 50 80 130 195 285 390 490 500

Critical Profile Points


Span 1 Locat mm -375 0 382.2 7000 13617.8 14000 14375
Height mm -161.5 -158.8 -182.1 -610 -182.1 -158.8 -161.5

Tendon 1 : - 4 - 4/12.7
mm
0
4

4
-200

-400

-600
500cl

500cl

1 2
490

390

285

195

130

130

195

285

390

490
80

50

40

50

80

Reinforcement
Reinforcement Reinforcement Preferred Number
Use Type Bar Size of Legs
List List #
Flexural Bar Y 500MPa
Flexural Mesh A 460MPa
Shear Option 1 Y 415MPa 8 2
Shear Option 2 Y 415MPa 10 2
Shear Option 3 Y 415MPa 12 2
Punching Shear Y 415MPa 10 2
RAPT 6.2.2.2 20-03-2019 12:56:37 Page 5/13
Licensee: License No.: 10255062220211WPN5
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar Bar Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement into End into Internal
Support Support
mm mm #.# #.# #.# Y/N Y/N
Support Reinforcement 300 60 0 N N
Span Reinforcement 300 60 0 0 N N

Design Zones : Top


Layer Steel Left End Distance to Bar stagger Top Cover Right End Distance to Bar stagger Top Cover Maximum Minimum Preferred Minimum
Number type Reference left end of length at left at left end Reference right end of length at at Right Bar Size Bar Size bar size Number of
Column bar end Column bar right end end Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 65 2 375 0 65 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Design Zones : Bottom


Layer Steel Left End Distance to Bar stagger Bottom Right End Distance to Bar stagger Bottom Maximum Minimum Preferred Minimum
Number type Reference left end of length at left Cover at left Reference right end of length at Cover at Bar Size Bar Size bar size Number of
Column bar end end Column bar right end Right End Bars
List mm mm mm mm mm mm List List List #
1 Bar 1 -375 0 50 2 375 0 50 12 10 12 0

Layer Maximum Minimum % in


Number Spacing of Steel area as Flange
Bars %
mm % %
1 0 0 0

Reinforcement Design Zones

1 2
mm
0

-200

-400

-600

0 14000mm
Design Data
Capacity Reduction factor (phi) for Flexure #.# 1
Capacity Reduction factor (phi) for Shear #.# 1
Material Factor for Concrete in Flexure #.# 1.5
Material Factor for Concrete in Shear #.# 1.5
Material Factor for Reinforcement #.# 1.15
Maximum Ratio of Neutral Axis Depth for Ductility #.# 0.5
Ductility Check at Left End Column Y/N Y
Ductility Check at Right End Column Y/N Y
Minimum Reinforcement Strength Limit - #.## x M* #.# 1.33
Flexural Critical Section - Consider Transverse Beams Y/N Y
Flexural Critical Section - Distance from centre of Support #.# -1
Beam Left Sideface Cover (Internal) mm 25
Beam Right Sideface cover mm 40
Prestress Minimum Reinforcement Basis List Program Default
Shear Enhancement at Supports Y/N Y
Ast Value in Shear Calculations List Calculated
AS3600 Shear Fitment Hooks Located at List Top of Fitment
Moment Diagram Offset For Flexure Calculations List Code Default
Limit Reinforcement Strain Y/N N
Beam Shear Critical Section Location List Code Critical Section

Maximum Service Stress Change - Prestressed Sections MPa 200


Maximum Service Stress Change - Reinforced Sections MPa 0
Relative Humidity % 50
Average Temperature C. 20
Prestress Losses Calculations based on List Program Default
RAPT 6.2.2.2 20-03-2019 12:56:38 Page 6/13
Licensee: License No.: 10255062220211WPN5

Crack Width Calculations List Code default


AS3600 Shrinkage and Temperature Reinforcement List Moderate
Degree of Restraint in Primary Direction % 0
Degree of Restraint in Secondary Direction % 0
Concrete Strength Gain Rate List N

Concrete Tensile Strength for Deflection Calculations- #.## x (Fc)n #.# -1


Maximum Value of Ieff/Igross for Deflection Calculations #.# 0.7
Total Deflection Warning Limit - Maximum Span/Deflection #.# 250
Total Deflection Warning Limit - Maximum Deflection mm 20
Incremental Deflection Warning Limit - Maximum Span/Deflection #.# 500
Incremental Deflection Warning Limit - Maximum Deflection mm 20
Time of Loading in days #.# 28
Age Adjustment Factor #.# 0.84
Concrete Strength at Time of Loading MPa 35
Loaded Period in years #.# 30
Tension stiffening Approach List Modified Concrete Tensile Modulus Method

Live Load Pattern Factor #.#


Pattern Live Load for Ultimate Strength Y/N
Pattern Live Load for Crack Control Y/N
Pattern Live Load For Deflections Y/N
Pattern Live Load for Deflection Permanent Load Combination Y/N

Material Properties
Concrete
Description 35MPa
Characteristic Compressive Strength 35
Mean Compressive Strength 41.72
Lower Characteristic Tensile Strength 2.96
Upper Characteristic Tensile Strength 4.75
Concrete Weight 2500
Design Concrete Modulus 33071.9
Mean Concrete Modulus 36107.5
Ultimate Concrete Modulus 15633.3
Basic Shrinkage Strain 385
Basic Creep Factor 3.4
Concrete Strain Limit 0.004

Prestress Strand
Diameter Area Breaking 0.2% 1% Breaking Design Elastic Plastic Basic Weight Material Material Material Material Capacity
Load Proof Stress Strain Strain Modulus Modulus Relaxation Factor Factor Capacity Reduction Factor
Stress Limit Flexure Shear Reduction - Shear
Factor - Flexure
12.7 98.71 183.7 85 82 0.06 90 1.95e5 2200 2.5 0.77 -1 -1 -1 -1

Include as Set as Description


Flexural default
Reinforcement
for Shear
Y Y ASTM A 416/A 416M-96 - 12.7mm dia 1860 N/mm2

Bonded Monostrand
Anchorage Description Transfer Anchor Draw-in Maximum Set as
Size Concrete Friction Jacking default
Strength Force
4 25 0 6 75 N

Live Deformed Nominal Full


End Strand Dead Swaged Dead Swaged
End End Dead End
Ineffective Length mm 100 100 100 100
Force at Start of Transition % 100 50 50 100
Transition Length mm 0 600 600 0
Force at End of Transition % 100 100 100 100

Number Duct Duct Duct Wall Centroid Duct Wobble - Minimum


of depth Width Thickness Distance Friction Unintentional Reverse
Cables Friction - K Curve Radius
# mm mm mm mm #.# 1/m mm
1 23 70 0.4 2.7 0.2 0.002 2800
2 23 70 0.4 2.7 0.2 0.002 2800
3 23 70 0.4 2.7 0.2 0.002 2800
4 23 70 0.4 2.7 0.2 0.002 2800
RAPT 6.2.2.2 20-03-2019 12:56:38 Page 7/13
Licensee: License No.: 10255062220211WPN5
Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 415 2e5 N 0.05 448.2 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.257e5 9.86 12000

Reinforcement Bar
Designation Type Yield Elastic Ductility Peak Peak Design Material Material Material Material Capacity Include as Description
Stress Modulus Strain Stress Strain Factor Factor Capacity Reduction Factor Flexural
Limit Flexure Shear Reduction - Shear Reinforcement
Factor - Flexure for Shear
Y Deformed 500 2e5 N 0.05 540 90 -1 -1 -1 -1 Y

Nominal Bar Bar Bar Bar Stock


Bar Size Diameter Area Inertia Weight Length
A mm mm2 mm4 kg/m mm
1 1 1.5 1 0.1 12000
8 8 50.3 201.14 0.4 12000
10 10 78.5 491.07 0.62 12000
12 12 113 1017.87 0.89 12000
16 16 201.1 3218.29 1.58 12000
20 20 314.2 7857.14 2.47 12000
22 22 380.1 11503.6 2.98 12000
25 25 490.9 19182.5 3.85 12000
32 32 804.2 51492.6 6.31 12000
40 40 1256.6 1.26e5 9.86 12000

Elevation view

1 2
mm
0

-200

-400

-600

0 14000mm

Plan view

mm 1 2
-1800

-900

900

1800
0 14000mm
RAPT 6.2.2.2 20-03-2019 12:56:39 Page 8/13
Licensee: License No.: 10255062220211WPN5
Full Elevation View

mm 1 2
4000

2000

-2000

-4000
0 14000mm
Warnings
Input
No errors or warnings were found.

Output
Warning:SUPPORT Reinforcing Bar Spacing There have been problems in determining a bar size to satisfy the design spacing requirements. See
Detailed Reinforcement Design Comments.

Prestress
Tendon Forces
Tendon 1 : - Gross Extension: 92.7mm - 4 - 4/12.7

1 2
kN
128

121

114

111
107

100
0 14000mm

Transfer Service Average

Tendon Actions
Forces from Tendon Profiles - Tendon 1 - 4 - 4/12.7

kN/m 1 2
800

600

400

200

0
0 -33.9 14000mm

Bending Moments
Load Cases
Column Actions
Col No. 1 Secondary Secondary Prestress Prestress Self Initial Live
Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm -146.59 -133.78 -146.59 -133.78 198.59 148.77 37
Moment Below kNm -187.52 -171.12 -187.52 -171.12 254.03 190.29 47.32
Reaction kN 0 0 0 0 225.65 169.04 42.04
Elastic Rotation #.# 0 0 -1.76e-4 -1.61e-4 2.38e-4 1.79e-4 0
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live


Transfer Service Transfer Service Weight Dead Load
Load
Moment Above kNm 146.59 133.78 146.59 133.78 -198.59 -148.77 -37
Moment Below kNm 187.52 171.12 187.52 171.12 -254.03 -190.29 -47.32
Reaction kN 0 0 0 0 225.65 169.04 42.04
Elastic Rotation #.# 0 0 1.76e-4 1.61e-4 -2.38e-4 -1.79e-4 0
RAPT 6.2.2.2 20-03-2019 12:56:39 Page 9/13
Licensee: License No.: 10255062220211WPN5

Col No. 2 Secondary Secondary Prestress Prestress Self Initial Live


Transfer Service Transfer Service Weight Dead Load
Load
Elastic Axial Shortening mm 0 0 0 0 0 0 0

Load Combinations
Column Actions
Col No. 1 Service Service Ultimate Ultimate Ultimate Ultimate
(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm 250.58 250.58 269.08 442.76 269.08 442.76
Moment Below kNm 320.53 320.53 344.19 566.35 344.19 566.35
Reaction kN 436.72 436.72 457.74 655.09 457.74 655.09
Elastic Rotation #.# 3.01e-4 3.01e-4 4.84e-4 6.92e-4 4.84e-4 6.92e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Col No. 2 Service Service Ultimate Ultimate Ultimate Ultimate


(Reversal) Flexure Flexure Shear Shear
(Reversal) (Reversal)
Moment Above kNm -250.58 -250.58 -442.76 -269.08 -269.08 -442.76
Moment Below kNm -320.53 -320.53 -566.35 -344.19 -344.19 -566.35
Reaction kN 436.72 436.72 655.09 457.74 457.74 655.09
Elastic Rotation #.# -3.01e-4 -3.01e-4 -6.92e-4 -4.84e-4 -4.84e-4 -6.92e-4
Elastic Axial Shortening mm 0 0 0 0 0 0

Ultimate Flexure

1 2
kNm
-1200
-788 -788
-800
-400
0
400
800
1200
1161
0 14000mm

Moment Moment 1 Moment 2

1 2
kN
800 588
600
400
200
0
-200
-400
-600
-800 -588
0 14000mm

Shear Shear 1 Shear 2

Flexural Design
Ultimate

1 2
mm2
300 223 256
250
200
150
100
50
0
-50
-100 0
0 14000mm

Reinforcement Top Total Bottom Total Top Ultimate Bottom Ultimate Min Top Min Bot
RAPT 6.2.2.2 20-03-2019 12:56:40 Page 10/13
Licensee: License No.: 10255062220211WPN5

1 2
kNm
-1200
-800
-400
0
400
800
1200
1600
0 14000mm

Capacity Minimum Ultimate Design Initial Final

1 2
0.354

0.353
0.5
0.4
0.3
0.2
0.1
0
-0.1

0.107
-0.2
-0.3
-0.4
0 14000mm

Neutral Axis Depth Initial Final

Service
Maximum Moment Condition

MPa 1 2 MPa
-1.8 -0.9 -6
-0.9 -3
0 0
0.9 3
1.8 6
2.7 9
3.6 12
4.5 15
4.32
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

MPa 1 2 MPa
-1.8 -0.9 -6
-0.9 -3
0 0
0.9 3
1.8 6
2.7 9
3.6 12
4.5 15
4.32
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 2 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 0.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.
RAPT 6.2.2.2 20-03-2019 12:56:41 Page 11/13
Licensee: License No.: 10255062220211WPN5
Transfer Prestress
Maximum Moment Condition

1 2
MPa MPa
-1.8 -15
-1.2 -10
-0.6 -5
0 0
0.6 0 5
1.2 10
1.8 15
2.4 2.37 20
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Reinforcement Tension

Permanent
Maximum Moment Condition

1 2
MPa -0.52 MPa
-0.7 -3
0 0
0.7 3
1.4 6
2.1 9
2.8 12
3.5 15
4.2 3.82 18
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Reversal Moment Condition

1 2
MPa -0.52 MPa
-0.7 -3
0 0
0.7 3
1.4 6
2.1 9
2.8 12
3.5 15
4.2 3.82 18
0 14000mm

Gross Stress Top Gross Stress Bottom Cracked Compression Axial Prestress Reinforcement Tension

Span 1
Design Comments:-
- SERVICE - CLASS 2 member to BS8110 cl.4.3.4.3(b,c) as Tensile Stress in Concrete > 0.
RAPT has carried out a cracked section analysis to determine steel stresses and will have added reinforcement if necessary to limit reinforcement stresses
and crack widths in accordance with BS8110 Part 2 cl.3.6 but allowing no tension in the concrete.

Shear Design
Beam
Span 1
Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
375 588.48 -788.47 704.84 487.8 223.27 1013.3 1.41e5 1099.93 1099.93 2339.64 1.12 89.6 139.8 201.2 Minimum Steel
895 542.29 -494.48 592.28 411.5 0 1013.3 708.13 1081.48 708.13 1973.49 1.12 89.6 139.8 201.2 Minimum Steel
1416 496.01 -224 489.3 353.1 0 1013.3 977.73 1063.93 977.73 1693.5 1.12 89.6 139.8 201.2 Minimum Steel
1937 450.12 19.3 35.92 350.1 0 1013.3 780.76 1045.9 780.76 1678.88 1.12 89.6 139.8 201.2 Minimum Steel
2458 403.84 241.76 120.58 398 0 1013.3 277.76 1027.48 277.76 1908.95 1.12 89.6 139.8 201.2 Minimum Steel
2979 357.57 440.11 196.18 440.8 0 1013.3 264.26 1009.42 264.26 2114.06 1.12 89.6 139.8 201.2 Minimum Steel
3500 313.03 603 262.67 478.4 0 1013.3 286.78 991.53 286.78 2294.21 1.12 89.6 139.8 201.2 Minimum Steel
4666 209.46 907.61 378.18 543.6 0 1013.3 325.87 951.59 325.87 2606.96 1.12 89.6 139.8 201.2 Minimum Steel
5832 109.65 1074.68 447.31 582.7 0 1013.3 349.34 911.18 349.34 2794.69 1.12 89.6 139.8 201.2 Minimum Steel
7000 -12.1 861.81 469.8 595.8 0 1013.3 357.18 870.09 357.18 2857.41 1.12 89.6 139.8 201.2 Minimum Steel
8166 -109.47 1074.89 445.46 582.8 0 1013.3 349.36 908.26 349.36 2794.91 1.12 89.6 139.8 201.2 Minimum Steel
9332 -209.28 908.03 374.47 543.7 0 1013.3 325.92 944.88 325.92 2607.39 1.12 89.6 139.8 201.2 Minimum Steel
10500 -313.03 603 256.86 478.4 0 1013.3 286.78 980.15 286.78 2294.21 1.12 89.6 139.8 201.2 Minimum Steel
RAPT 6.2.2.2 20-03-2019 12:56:41 Page 12/13
Licensee: License No.: 10255062220211WPN5

Locat V* Mv* Mdec d Ast bv phi Vuc phi Vut phi Vu Phi Vumax Asv/s Spacing of Sets Shear Comments
2 legs 2 legs 2 legs
Y8 Y10 Y12
mm kN kNm kNm mm mm2 mm kN kN kN kN mm2/mm mm mm mm A
11021 -357.57 440.11 189.51 440.8 0 1013.3 264.26 995.61 264.26 2114.06 1.12 89.6 139.8 201.2 Minimum Steel
11542 -403.84 241.76 113.04 398 0 1013.3 269.18 1011.06 269.18 1908.95 1.12 89.6 139.8 201.2 Minimum Steel
12063 -450.12 19.3 27.52 350.1 0 1013.3 625.57 1026.69 625.57 1678.88 1.12 89.6 139.8 201.2 Minimum Steel
12584 -496.01 -224 475.27 353.1 0 1013.3 954.67 1042.69 954.67 1693.5 1.12 89.6 139.8 201.2 Minimum Steel
13105 -542.29 -494.48 578.29 411.5 0 1013.3 698.99 1059.33 698.99 1973.49 1.12 89.6 139.8 201.2 Minimum Steel
13625 -588.48 -788.47 690.88 489.4 255.65 1013.3 1.46e5 1076.89 1076.89 2347.35 1.12 89.6 139.8 201.2 Minimum Steel

mm 1 2
200
180
160
140
120
100
80
60
40
20
140 *
0
0 14000mm

Reinforcement Requirement 2 legs Y8 2 legs Y10* 2 legs Y12

1 2
kN
1200
800 588
400
0
-400
-800 -588
-1200

0 14000mm

Capacity .5 * Conc Capacity Conc Capacity Min Capacity Max Allowable Applied V*

Deflections
Live Load on All Spans
Transfer

1 2
mm
0
0.278
-6

-12

-18

-24
50045
0 14000mm

Short Term

1 2
mm
0

-6 -3.68

-12

-18

-24
3772
0 14000mm
RAPT 6.2.2.2 20-03-2019 12:56:42 Page 13/13
Licensee: License No.: 10255062220211WPN5
Incremental

1 2
mm
0

-6
-5.9
-12

-18

-24
2354
0 14000mm

Total Long Term

1 2
mm
0

-6

-12 -8.88

-18

-24
1566
0 14000mm
DESIGN OF POST TENSIONED SLAB
Project  : HAL TESTRIG BLOCK Designer : NAGENDRA
Floor  : 5TH SLAB Date         : 20‐03‐2019

Location  :  5 PTB 11,12,13,15,17,19,20


Calculation of Moment Resisting Capacity
According to IS:1343 ‐ 1980 the Moment of Resistance of a section due to tendons can be 
calculated as follows.
                     M =  ƒpu Ap (d ‐ 0.42 xu)

Where,
M  ‐  Moment Resisting Capacity of section
ƒpu  ‐  Ultimate Tensile stress in Tendon
Ap  ‐  Area of prestressing steel

d  ‐  Effective depth of section
xu  ‐  Depth of neutral axis

Design Data:
2
Grade of concrete ƒck  = 35 N/mm
2
Grade of steel ƒy  = 415 N/mm
2
Grade of prestressing strand ƒp  = 1860 N/mm
Depth of beam D  = 650 mm
Web width bw  = 1200 mm
Depth of slab Df  = 150 mm
Effective flange width bf  = 3160 mm
Dia of strand used  = 12.7 mm
Tendon Arrangement
First Layer Duct  ‐  5S , Total Number of strands  = 16 nos.
Second Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Third Layer Duct  ‐  5S , Total Number of strands  = 0 nos.
Fourth Layer Duct  ‐  20S , Total Number of strands  = 0 nos.
Total Number of strands  = 16 nos.
Clear cover from soffit of tendon to soffit of slab (1st Layer)  = 40 mm
Clear cover from soffit of tendon to soffit of slab (2nd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (3rd Layer)  = 0 mm
Clear cover from soffit of tendon to soffit of slab (4th Layer)  = 0 mm
Ap 2
Area of prestressing steel  = 1579 mm
Effective depth of section with respect to 1st Layer tendon  = 596
Effective depth of section with respect to 2nd Layer tendon  = 0
Effective depth of section with respect to 3rd Layer tendon  = 0
Effective depth of section with respect to 4th Layer tendon  = 0
Effective depth (d)  = 596.0 mm
Effective reinforcement ratio (Ap * ƒp / (b * d * ƒck)  = 0.045
From Table ‐11 of code
Stress in Tendon as a proportion of the design strength
ƒpu / (0.87 * ƒp)  = 1.00
ƒpu  = 1618.2
Ratio of the depth of Neutral Axis to that of the centroid of the tendon in the tension zone
xu / d  = 0.097
xu  = 57.837
Moment resisting capacity of section by Tendons  = 1461 kN‐m
Reinforcement Provided  = 4T20+2T16+ADD'L(2T16)
Ast  = 2
2060 mm
Cover to Main Reinforcement  = 25 mm
Effective depth to reinforcement  = 625 mm
Moment resisting capacity of section by rebar  = 87 * ƒy * Ast * d *
 (1‐((Ast * ƒy)/(ƒck * b * d * )))

 = 459 kN‐m
Design Moment at critical section  = 1161 kN‐m
Total Flexural capacity of section  = 1920 kN‐m
Calculation of stress @ Service:‐
Area of Gross cross section A  = 1E+06 mm2
Area of flange  = 474000
Area of web  = 600000
Y1  = 75
Y2  = 400
Depth of Neutral axis from top fiber yt  = 256.56
Depth of Neutral axis from bottom fiber yb  = 393.44
Moment of Inertia of T section Ixx  = 41358722067

Section modulas zt  = 2E+08
Section modulas zb  = 1E+08
Eccentricity e  = 339.4 mm

Available tendon force at service (1st Layer)  = 111 kN
Available tendon force at service (2nd Layer)  = 0 kN
Available tendon force at service (3rd Layer)  = 0 kN
Available tendon force at service (4th Layer)  = 0 kN
Effective force per strand  = 111.0 kN
Total effective force @ Service P  = 1776 kN
Moment due to self weight  = 295 kN‐m
Moment due to super imposed dead load  = 221 kN‐m
Moment due to Live load  = 54.9 kN‐m
Secondary Moment  = 305 kN‐m
Moment due to Earthquake load  = 0 kN‐m
Combination for Limit state of serviceability  = 1.0 (DL + LL + PT)
Service Moment  = 875.9 kN‐m
Stress due to direct prestress  = P/A
 = 1.65
Stress due to tendon eccentricity @ Top fiber  = Pe/zt

 = 3.74
Stress due to tendon eccentricity @ Bottom fiber  = Pe/zb

 = 5.73
Stress due to Applied loads @ Top fiber  = M/Zt

 = 5.43
Stress due to Applied loads @ Bottom fiber  = M/Zb

 = 8.33

ƒt 2
Stress at extreme top fiber  = 3.35 N/mm
Stress at extreme bottom fiber ƒb  = ‐0.94 N/mm2
Negative sign indicates Tensile stress.

S-ar putea să vă placă și