Operation Principle of the HTSR Type Three Lobes Roots Blower……1
Two、Fan installation requirement……………………………….1
Three, Piping requirements…………………………………………….1
0
Four、 Before starting the attention of …………………….1
Five、Job description ………………………………………………….3
Six、 Daily maintenance and repair of fan
Seven、 Safety valve instructions……………………………… 4
Eight、The cause of the fan fault exclusion measures ………5
Nine 、After sales service and repair……………………………7
1
Piping requirements
1, fan pipe should be tight, not leak, in the appropriate
position of the stent.
2, piping material should be able to withstand the exhaust
temperature and wind pressure (as far as possible the use of steel
tubes).
3, the pipeline must be clean, free of foreign matter, to prevent
the entry of debris.
4, the pipeline to install a check valve to prevent the wind
caused by the reverse flow into the fan.
Note: check valve should be installed in horizontal pipe.
5, multi typhoon machine parallel operation of the occasion, each
branch pipe should be set to set the gate valve (one of the
typhoon machine maintenance, can cut off the pipeline).
6, the pipeline should be equipped with emptying valve, to prevent
the wind turbine with load starting, the wind turbine should be
no-load start and then close the exhaust valve with load
operation.
7, a water cooling system, cooling water inlet valve to configure
the.
Before starting the attention of fans
1、 Check the anchor bolt connection is strong.
2、removal of welding slag and other foreign bodies.
3、Valve must be placed in full state, or the wind machine
overload operation, the wind turbine damage.
4 - Filling gear oil. When leaving the factory, the oil is not
filled in the oil tank, please fill up the gear oil. In the
shutdown state, in addition to the central oil window can not add,
otherwise it will lead to oil spill.
5、filling bearing grease, available oil added to oil from the
gland of the oil drain hole overflow so far (wind machine factory
was added to grease).
6 - Check the tightness of the narrow V belt and the belt pulley.
The pulley is available is a partial. The tightness of the belt
can be adjusted under the table. When used for a period of time
After the belt will become
loose, this time to re adjust.
电机 鼓风机
钢板尺 皮带轮
皮带轮
2
风机型号 W(kg) δ(mm)
7、In the process of
transportation and field Fan
installation, the direct coupling
fans may cause the relative model
displacement of the two coupling. HTSR-40 1-1.5 3.5
Before operation, the coupling
must be checked and found, so as HTSR-50 1-2 4
not to affect the normal
operation of the fan. HTSR-65 1-1.7 4.5
8 、 Check whether the power HTSR-80 1.5-2.5 4.5
supply voltage and frequency are
in compliance with the HTSR-100 2-3 5.5
requirements of label marking.
HTSR- 1.5-3 6.5
9、Check pulley. In the face 125A
of the belt pulley, the belt
pulley is rotated in an anti HTSR- 3.5-5 7
clockwise direction. 150A
10、Before starting with the
hand to turn the belt, if no HTSR-175 3.5-5 7
abnormal, you can start the fan.
11 、 High pressure water- HTSR-200 4-5.5 8
cooled fan startup, first open HTSR-250 4-5.5 8
the switch of cooling water;
shutdown, the first turn the fan HTSR-300 4-5.5 8
after the disruption of water
HTSR-350 4-5.5 8
supply, at temperatures below - 1
DEG C, shutdown to drain, frozen tank
Job description
1、Due to the viscosity of the lubricating oil in the initial
operation, the noise and the current may be too high, and then
disappear after 10 ~ 20 minutes.
2、The gas flow rate can be adjusted by changing the overflow
pipe after changing the speed of the fan.
3、The fan should work in the calibration of the pressure
plate. When the fan works, the pressure gauge to switch in the
closed state, for determination of pressure, it will switch to
open and close it again after the test.
3
4、The same type of noise are
外壳
different, because of differences in
the different position of fan and 滤芯框
noise.
5、Fan in the use of the
process, should pay attention to
check the filter element of the
filter is blocked. After the
blockage will increase the motor
power, and even damage the motor. So it should be cleaned in time.
6、When the fan pressure is greater than 58.8kpa, the increase
of water cooling system user. The cooling water is less than or
equal to 25 DEG C, pressure 196-294kpa, flow 8-13L/min. With
cooling system fan and ordinary fan shape, only the main and
auxiliary fuel tank increased water interface, according to the
requirements of import water can be connected.
六、风机的日常保养和检修
electric current ▲
Below motor nameplate value
The nameplate value is
Voltage ▲
less than 10%
4
2 weeks to add a three
Check bearing grease ▲
months to replace once
Replace V belt ▲
▲
Replace bearing
Note: at first, the gear oil must be replaced after one month.
1 Gear oil: N220 load industrial gear oil
Viscosity: mm2/S (40): 198-242 flash point (not less than 200 DEG
C):
(2) Butter (lubricating oil): ZL-3H synthetic lithium base
grease
八、 故障排除
fault reason measures
Hand can be
Motor damage Repair or replace the motor
Do not inverted
turn
Hands can not Rotor block Open repair
turn
turn Containing impurities Open repair
Abnormal sound or
Slip, V belt too tight or
机 vibration
too loose Adjust the belt tension
Fan
Belt pulley To adjust the belt pulley
Belt pulley and belt
Aligning belt cover
cover friction
6
Strengthen the strength of
Foundation strength is
the foundation
not enough
Through the muffler and
Pipe resonance
bracket elimination
Exhaust pressure rise See * Note
Exhaust pressure
See * Note
suddenly rises
7
The valve is broken or
twisted in the opposite Change or reverse direction
direction
Correct connection or
Switch or line maintenance
connection is bad
Hand can be Not even a single line Check for repair or
Do inverted
electric or a fuse replacement
not
machinery Improve power supply
turn
Abnormal power supply facilities
overheated 40℃
Fan engine room
turn temperature rise more Increase ventilation
than
40 C
Improve power supply
Abnormal power supply
Speed is too low facilities
overload Adjust the air pressure
8
② Improper use of the company, the company designated
professional maintenance personnel to repair, or to repair the
failure of the machine itself.
③ Fault caused by natural disasters.
④ Failure caused by maintenance and maintenance not in
accordance with the specification.
⑤ Use the non company designated standard parts caused by
failure.
⑥ Replacement of wearing parts.
⑦ Does not belong to the design or manufacture.
model
Manufacturing
number
Shaft
power
speed
pressure
date of
production
Customer name