Figure 1 Click image to view larger ASME Section IX specifies the ranges of production welding positions.
They've been used since the first Section IX of the ASME "Boiler and Pressure Vessel Code"
emerged in 1941, and most likely before. They've been a mainstay of welding schools and
central to welder qualifying tests for generations. They use arbitrary numbers to indicate
position of the weld, from 1 (flat) to 4 (overhead). The G stands for groove, F for fillet. The
number 5 comes up when welding a pipe groove when the pipe axis is horizontal (5G), and 6
when the pipe axis is inclined at a 45-degree angle (6G).
But note: These are not production welding positions.
Instead, they're standardized testing positions. More precisely, they are discretely defined
positions of test coupons used when testing welders and sometimes procedures. Per welding
codes, each test position has a tolerance of ±15 degrees from the defined horizontal and
vertical planes and ±5 degrees from a defined inclined plane. Based on the position in which
the welder tested, Section IX provides table QW-461.9 that shows the welding position (flat,
vertical, overhead, or horizontal) for which the welder is qualified; other codes provide similar
tables.
The same goes for weld-test designations in ISO 6947, "Welds—Working Positions—
Definitions of Angles of Slope and Rotation." Its PA, PC, PF, PG, PE, and pipe PF
designations roughly correspond to 1G, 2G, 3G, 4G, and pipe 5G test positions used by U.S.
codes. (For pipe welding, the ISO code designates the 6G position as two separate tests, uphill
[HL045] and downhill [JL045].)
Regardless, these designations refer only to test welding positions, not to production welding
positions, which are contiguous and cover all possible orientations.
Admittedly, making the distinction between test and production positions isn't as much of an
issue now as it was before 1974, when ASME Section IX welding procedures also had to be
qualified for the positions in which they would be used. Nevertheless, the industry needs new
welders more than ever, and communicating welding basics has never been more important.
This article, therefore, serves two purposes. First, it clarifies the distinction between test and
production weld positions for groove welds in plate. Second, it gives illustrations that clarify the
myriad welding positions possible, positions any new welder or inspector needs to understand
when entering the field.
Figure 2 Click image to view larger The 1G test position allows the welder to perform welding with the
weld face rotated no more than 5 degrees. The plate may not tilt more than 15 degrees up or down
(horizontal plane).
Figure 5
Click image to view larger
For horizontal-position welding, the weld face rotation can be anywhere from the plate rotated
30 degrees from the flat plane and continues for another 70 degrees, to 110 degrees, just past
vertical (A). It can vary 15 degrees, up or down, along the weld's vertical axis (B and C).
Compare this with the flat position for a groove weld in plate, as described in ASME Section IX,
AWS D1.1, and other construction codes: The inclination can be 0 to 15 degrees, but the
rotation of the weld face is from 150 to 210 degrees. In other words, the plate can tilt side to
side up to 30 degrees and still be considered a flat weld (see Figure 3).
The same applies for the 2G test position (see Figure 4). Again, the test position varies only by
the amounts specified in the figure. It does not equate to but is instead a subset of the myriad
variations possible in the horizontal production welding position, which starts where the flat
position left off, and rotates around, shown in Figure 5.
Per code, the 4G test involves a weld in a horizontal plane with the weld metal deposited from
underneath. 4G is indeed an overhead position, but just one among many, as Figure 6shows.
The plate can rotate and incline by a significant amount and still be called overhead-position
welding. However, with all overhead groove welds, the root is on top and weld metal is fed from
underneath.
Vertical welding, per the code, has an inclination axis of 15 to 80 degrees, during which the
weld face may rotate from 80 to 280 degrees—or 200 degrees side to side. When the weld
inclination is between 80 and 90 degrees, the weld may rotate all the way around, 360
degrees, and still be called a vertical weld (see Figure 7).
Figure 7
Click image to view larger
A vertical-position weld can be inclined anywhere from 15 degrees off the horizontal plane to
vertical (A and B). From 15 to 80 degrees of inclination, the plate may be rotated anywhere
within a 200-degree range (C). Between 80 and 90 degrees of inclination the plate may be
positioned anywhere along the 360-degree axis of rotation (D).