Documente Academic
Documente Profesional
Documente Cultură
EXTERIOR FOOTING F2
DATA
DESCRIPTION Value Unit
Soil Bearing Capacity, qₐ* 120 kPa
Steel Strength, fy 276 Mpa
Concrete Strength, f'c 28 Mpa
Unit Weight of Soil Above the Footing, δs 15.2 kN/m³
Unit Weight of Concrete, δc 24 kN/m³
Dead Load, DL 528.43 kN
Live Load, LL 66 kN
Earthquake Load, EL 405.2 kN
Bending Moment, MEL 130.35 kN-m
Column Size 350 mm
Excavated Depth of Footing, h 1.8 m
Diameter of Main Bar, db 25 mm
Diameter of Column Bar, dc 25 mm
Steel Covering 75 mm
Factored Load, Pu 1105.316 kN
Beta Factor, ϕ 0.85
* See National Building Code of the Philippines, Table 7.04 -(A) for the value of qa
qe = 90 kPa
Dimension of Footing:
12 m²
3.46 m
Combined Axial Load and Bending:
P = PU = 999.63 kN
M= 130.35 kN-m
-64.49 kPa
-110.92 kPa
Check if the effective depth of footing is adequate for wide beam shear:
1.37 m
64.49
46.44
2.09 m
110.92
By Ratio and Proportion:
28.08 kPa
92.57 kPa
482.70 kN
>
SAFE
572.82 kN
486.90 kN
Steel Requirements:
1.56 m
64.49
46.44
1.91 m
110.92
273.91 kN-m
2.50 Mpa
Steel Ratio: 1
0.000923517
0.005072
0.037653
0.005072
3294.66 mm²
7 25
512.07 mm
414 mm
999.63 kN
2040.85 kN
3.46 3.46 12
9.90 > 2
612.5 mm²
25
Details:
1
0.5