Sunteți pe pagina 1din 1

GENERAL NOTES :-

1. All dimensions are feet inches,


unless other wise
specified.
2. Do not scale drawings,only
written dimensions shall be
followed.
3. Discrepancies noted shall be
brought to the notice of the
consultant priorto execution.
4. This drawing is based on
arch. drgs.
5. The drawing shall be read in
conjunction with other
structural and architectural

A B C D drawings
6. Clear cover to main
reinforcement shall be 50mm
in footings,40mm in columns.
36'-0" 7. The mix of concrete shall be
M-25 grade in foundation
26'-41" 7'-0" 1
2'-7 " and M-20 grade in column
2 2 8. Reinforcement shall be
fe -500D grade conforming to
4 "
1
2

4 "
is 1786.

1
2
2'-6" 3'-6" 9. Min lap length shall be

1 1 provided as per is-456-2000


10. Details should be done as per
3'-6"

sp-34.
C-1 CF-1 RAFT-1 C-3 C-6 11. Spacer bars:- shall be 20mm dia at

5'-9"
max.4'-0"(1200 mm) intervals
12.The period of curing should not be
less than 10 days for all the
concrete components such as column,
slabs, footings exposed to
hot and dry weather conditions.
12'-10 "

12'-10 "
1

1
2

2
4'-721" 9'-71"
13'-3"

13.For plastering and brick stone wall


2 footings the period of curing should
3'-1021" 7'-0" 2'-71" not be less than 7 days.
2 14.Minimum period before striking all
RCC work are as follows
Vertical form work to columns, walls,
RAFT-2 beams is 16-24 hours.
4'-71"

Soffit form work to slabs(props to be


2

re-fixed immediately after removal of


form work) is 3 days.
Soffit form work to beams (props to be

2 2 re-fixed immediately after removal of


form-work) is 7 days.
15.Props to slabs:
C-7 C-5 Spanning up to 4.5 m is 7 days
C-2
5'-10 "

5'-10 "
Spanning over 4.5 m is 14 days
5'-1021"
1

1
2

2
Props to beams and arches
Spanning up to 6 m is 14 days
Column size increased by 5%. Spanning over 6 m is 21 days
16.Site should be inspected by qualified

3 Reinforcement also increased 3


engineer.
12'-1021"

17. This building is designed for B+G+4


EXISTING STONE WALL
45'-0"

45'-0"
7'-0"

7'-0"
7'-0"

C-7
C-5
4 4
4'-71"
2

C-2
Does lift have RCC wall around?
1
3'-102" 7'-0" 2'-721"
FB-1(30"X30")

PROJECT TITLE:-
18'-6"

18'-1021"

18'-6"

1'-3" 1'-3" SHOWROOM OF


8'-421" 9'-721" MR. DEENDAYAL JI
ARCHITECT:-
AGGRAVASTU,
CF-2 ARCHITECT,ENGINEER,INTERIOR DESIGNORS
6,7 GOPALPURA BYE PASS JAIPUR-
4'-9"

STRUCTURAL CONSULTANT

FB-2(36"X36") HiDPl DESIGN GROUP


3'-6"

C-4 STRUCTURAL CONSULTANT


3'-0"

HORIZON INFRA DESIGNS PVT. LTD.


C-4 C-5 21-B, First Floor, Vasundhara
5 5 Colony Tonk Road, Jaipur - 302018
Phone No. 0141-2700862
4 "

41"

0141-2702594
1
2

1 Mobile No:-9799523888
26'-4 " 7'-0" 2'-71" E-mail:-ksdesigngroup@gmail.com
2 2
DESIGNED BY:- DEALT BY:-
36'-0"
ASHOK MUKESH

A B C D CHECKED BY:-

KAPIL SARAWAGI
DATE:- JOB. NO:- DRG. TITLE:-

FOUNDATION LAY
15-02-19 190222
OUT PLAN

DRG NO :-
S-01
REVISION:-(1) 21-02-19

PATH:- Server/PC-3/D/Autocad Files-2019/


Santosh Agarwal/Deendayal ji