Sunteți pe pagina 1din 1

A B C D E F 4 G H I J K L M N O P Q

S-0006

REFER TO DRG. S-0007


FOR RETAINING WALL RITEK WALL
600 2400
FOOTING STEP DETAIL EXTENDS 10m
PAST GRID Q

550 550

9
SF1 RW1 RW1 RW1

W1
SF1 SF1
5 MAX. 1200 DEEP

KCJ

KCJ

KCJ
ELECTRICAL TRENCH

KCJ
S-0008 W1 W1 W1
8 RITEK WALLS TO TRENCH. REFER

KCJ
TO DETAILS ON S-0008 TYPICAL.
1
7
S-0006 MAX. 1200 DEEP
ELECTRICAL TRENCH S-0008

4
4
2

9
C0

3
2
1

C1
C0

C0

C0

C0

C0

C0

C0
C0

C1

C1

C1
C1
PF3
7
4
6
C6

S-0008 PF1 PF2 PF1


PF3 PF3 PF4 PF3 PF4 PF4 PF4 PF4 PF4 PF4 PF4
RW2

GREASE TRAP

1000
6
RW1

W1

KCJ
S-0008
1000

KCJ

KCJ

KCJ

2000
200
600 DIA. CFA WALL

KCJ

ET1
6
ST1
SL

C1
C1
AB
RW2

8
W1 1000
S-0008 4800

PF3 PF3

1000

1000

1000

2
1
3

4
0

0
C1

C3
1

C3
C8

C2

C2

C2

C2

C2

C2

C2

C2

C2

C3
C2
KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ KCJ
6
RAMP UP

W1
ET1

KCJ
C1

C1

PF2 PF2 PF1

KCJ
2

KCJ
PF3 PF3

KCJ
KCJ

6
1
8

C4
S-0008

C4
C3
RW2

1200

7
3

4
4

3
5

C4

C4
C3

750

C4

C4

C4

C4
C3

C3

C3
C8

C3

7
KCJ

C3
5 S-0006
1200

RAFT 1
3 PF1
RW

PF5

W1

W1
PF5 PF5 PF5

W1
PF1 PF3

SHEAR WALL 1
S-0008
2

8
C4

KCJ

KCJ

KCJ
750 750

KCJ
1000

LIFT
2 PF5 ST6

PIT
ST2 ST3
S-0006
1 1000

2
4
0

9
C5

C6

C6
1
C5

C5

C5

C5

C5

C5
C5
9
C4

S-0008
4 2 1000

1200
RW2 S-0007

750

1000
1250

1250
PF2 RAFT 5

1
PF3 PF3 PF3 PF3

3
PF3 PF3

C6
C5
C5
PF1 RAFT 3
60 750 1000 750 1200 1200
0
DIA RAFT 2 RAFT 4 1000 RAFT 6
3 CF
A BOTTOM OF RAMP
WA TEMPORARY RETAINING WALLS

KCJ
LL DRAIN PIT DRAINAGE SUMPS IN TO BE DEMOLISHED IN STAGE 3
KCJ

KCJ
LIFT PIT. REFER ARCH.

KCJ

KCJ
6 FOR LOCATIONS

S-0007
2
ET1
1
600 DIA. CFA WALL 600 DIA. CFA WALL
3
S-0006
ALL GRADES AND REFER TO DRG. S-0007
FALLS TO ARCHITECTS FOR TYPICAL SUMP PIT
DETAILS DETAIL
NOTE: PILE WALL
EXTENDS 10m
PAST GRIDLINE Q

BASEMENT - GENERAL ARRANGEMENT PLAN


SCALE: 1 : 100
NOTES:
• FOR GENERAL NOTES REFER TO DRAWING S-0002, S0003
• FOR TYPICAL SLAB ON GROUND DETAILS REFER TO DRAWING S-0007
• 100 MINIMUM SLAB ON GROUND UNO
• SLAB TO BE POURED ON 50 MINIMUM COMPACTED SAND UNO
• SLABS TO BE POURED ON AN APPROVED DAMP PROOF MEMBRANE
• REINFORCE SLABS WITH SL72 MESH TOP THROUGHOUT
• FOR EXTRA REINFORCEMENT AROUND COLUMNS REFER TO STANDARD
DETAILS
• CONCRETE STRENGTH TO BE f'c = 32MPa
• PROVIDE 1N12 TRIMMER (1000 LONG) TO UNDERSIDE OF MESH AT ALL RE-
ENTRANT CORNERS UNO
• PROVIDE 10 JOINTEX OR APPROVED EQUIVALENT BETWEEN COLUMNS,
WALLS AND SLABS. TYPICAL
• ALL GRADES AND FALLS TO ARCHITECTS DETAILS
• REFER ARCHITECT'S DRAWINGS FOR LOCATIONS OF HOBS, SPOON DRAINS
AND KERBS
• REFER TO ARCHITECT'S AND HYDRAULIC ENGINEERS DRAWINGS FOR
LOCATION OF HYDRAULIC PITS, PERIMETER DRAINS AND SERVICES
INFORMATION
• REFER TO DRG. S-0161 FOR COLUMN SCHEDULE AND DETAILS
• REFER TO DRG. S-0165, S-0166 FOR CORE WALL ELEVATIONS
• REFER TO DRG. S-0167 FOR SHEAR WALL ELEVATIONS

LEGEND:
KCJ
DENOTES KEYED CONTROL JOINT REFER TO DRG. S-0007 FOR DETAILS

ET1
DENOTES EDGE THICKENING REFER TO DRG. S-0007 FOR DETAILS

PAD FOOTING SCHEDULE RAFT SCHEDULE WALL SCHEDULE


MARK WIDTH LENGTH THICKNESS B1 B2 T1 T2 MARK THICKNESS COMMENTS MARK THICKNESS TYPE REMARKS
PF1 2100 2100 550 12N20 12N20 RAFT 1 1000 REFER TO DRG. S-0010 FOR DETAILS RW1 200 RITEK REFER TO DRG. S-0006
PF2 2400 2400 625 10N24 10N24 RAFT 2 1000 REFER TO DRG. S-0010 FOR DETAILS RW2 200 RITEK N12-200 EW RETAINING FACE,
PF3 2700 2700 800 10N28 10N28 RAFT 3 800 REFER TO DRG. S-0011 FOR DETAILS N12-300 EW NON-RETAINING FACE
PF4 3000 3000 900 13N28 13N28 RAFT 4 1000 REFER TO DRG. S-0010 FOR DETAILS W1 200 RITEK N12-300 EW EACH FACE
PF5 6000 3000 900 10N28 10N28 20N16-300 11N24-300 RAFT 5 800 REFER TO DRG. S-0010 FOR DETAILS
PF8 1750 1750 400 7N16 7N16 RAFT 6 1000 REFER TO DRG. S-0011 FOR DETAILS

RETAINING WALL FOOTING SCHEDULE


REINFORCEMENT
MARK DEPTH WIDTH
B1 B2 T1 T2
RW1 400 1500 N12-300 N12-300 N16-300 N12-300
RW2 300 1200 N12-300 N12-300 N12-200 N12-300

CLIENT PROJECT STATUS TITLE


F 16.02.2015 ISSUED FOR TENDER RDM
E 03.02.2015 ISSUED FOR INFORMATION RDM ISSUED FOR TENDER BASEMENT GENERAL
D 19.01.2015 ISSUED FOR INFORMATION RDM ST. IVES CARINE
C 23.12.2014 ISSUED FOR INFORMATION RDM DRAWN DESIGNED CHECKED APPROVED
ARRANGEMENT PLAN
B
A
28.11.2014
14.11.2014
ISSUED
ISSUED
FOR
FOR
INFORMATION
INFORMATION
RDM
RDM
RETIREMENT VILLAGE CA LCH BG RDM
DATUM GRID SCALE PROJECT No. DRAWING No. REV.
REV DATE DESCIPTION RVD REV DATE DESCIPTION RVD
REVISIONS REVISIONS As indicated AT A0 SIZE P14065 S-0005 F
© BG&E Pty Limited