Sunteți pe pagina 1din 6

Multilink  N

Truly universal

A strong bond provides support


and inspires confidence

h
roven wit
ally p
Clinic
Multilink N
®

Strong adhesion – long-lasting bond

Versatile application

Multilink N is characterized by its versatile application possibilities:


One product system covers a multitude of indications.

The universal luting composite system Multilink® N


is suitable for the adhesive cementation of metal,
metal-ceramic, all-ceramic and composite resin restorations.

Due to the fast and efficient self-curing mechanism, Multilink N is highly recommended in
cases where cementation with light-activated materials is not possible as a result of restricted
or hampered access to light (e.g. oxide ceramics, opaque glass-ceramics or alloys).

Proven products for a long-lasting bond


Quality restorations deserve the best possible placement. Quality cementation results are produced
with co-ordinated, scientifically proven products:

The universal cleaning paste Ivoclean Excellent adhesion between the luting com-
effectively cleans the bonding surfaces posite and the restoration is achieved with
of prosthetic restorations after intraoral the new bonding agent Monobond N. Only
try-in and thus creates optimum pre- one primer is necessary to establish a long-
requisites for the adhesive luting lasting bond to all-ceramic, metal, metal-
procedure. ceramic and composite resin restorations.

Clean the restoration with Ivoclean. Thoroughly rinse with water spray and dry Prime the bonding surface of the restoration
with oil-free air. with Monobond N.

Allow the material to react for 60 seconds. Disperse any remaining excess with a strong Apply Multilink N and seat the restoration.
stream of air.
Multilink N
®

Easy clean-up of excess material

Due to the advanced Easy Clean-Up formula Flexural strength | MPa


and the Quarter Technique, excess Multilink N
140 136
is now even easier to remove.
120
100 99
84
What makes Multilink N so special is that it
80
offers both, easy removal of excess and 60
consistently high flexural strength. 40
20
0
Multilink N RelyX U200* Panavia F2.0*
Source: C.A. Muñoz, University at Buffalo, USA, 2013

Quarter Technique
Depending on the curing light used, excess can
be light-activated in 1 to 3 seconds per quarter
surface (mesio-oral, disto-oral, mesio-buccal,
disto-buccal).

1st quarter surface

Within this time, the material acquires a gel-like


consistency, which makes it easy to remove with
a scaler. Multilink N impresses with excellent
properties.

2nd quarter surface

3rd quarter surface

4th quarter surface


Multilink N
®

Impresses with excellent properties

Strong adhesion and excellent properties

Strong adhesion – long-lasting bond


Shear bond strength | MPa | immediate | lc
30 The luting composite and self-etch adhesive
26 Dentin
25 (Multilink N-Primer) of the Multilink N-System
Enamel are specially co-ordinated. The self-etch
20
15 14 adhesive seals the dentin and ensures mar-
15
10 10 ginal integrity and high bond strength on
10 8
5 enamel and dentin, which is attained in only
0 ten minutes.
Multilink N RelyX U200* Panavia F2.0*
Source: C.A. Muñoz, University at Buffalo, USA, 2013

Water absorption | µg/mm3


0 Low water absorption
10 Water absorption has an adverse effect on
20
the volume, colour stability and translucency
of the material. If water is absorbed, the
30 27 26
bond between the matrix and filler is first
40 36 weakened and eventually, the stability of the
Multilink N RelyX U200* Panavia F2.0* material decreases because of the water
Source: NIOM, Helsinki, Finland, 2012 retained in it.

Water solubility | µg/mm3

0 Low water solubility


0
1 Water solubility causes the material
2 1,2 to leach out of the restoration
3 margins resulting in marginal leaks
4 3,5 (risk of secondary caries).
Multilink N RelyX U200* Panavia F2.0*
Source: NIOM, Helsinki, Finland, 2012

Radiopacity % Al
High radiopacity
400
Radiopacity facilitates oral diagnosis and
350
differential diagnosis of secondary caries
300
and marginal gaps. Only composite
200 160 materials having a radiopacity of at
110
100 least 200% Al can be reliably distin-
0 guished from the tooth structure.
Multilink N RelyX U200* Panavia F2.0*
Source: R&D Ivoclar Vivadent AG, Schaan,
Liechtenstein, 2012

*RelyX U200 and Panavia F2.0 are not registered trademarks of Ivoclar Vivadent.
Well-known voices
Multilink N is endorsed by distinguished professionals

The features of Multilink N that users appreciate the most:

“Strong and esthetic,


for long-lasting restorations.“
Dr Eduardo Mahn,
Chile

“Impressive chemistry, a varied range


of indications and easy application.“
Dr T.C. Phua,
Singapore

The way out of the cements maze


The Cementation Navigation System, a new multimedia application from Ivoclar Vivadent, offers
dentists practical orientation and guidance in the selection of the best luting material for each case.
CNS www.cementation-navigation.com
Fixed Prosthetics

Multilink® N forms a part of the “Fixed Prosthetics” product category. The products of this category cover the procedure
involved in the fabrication of fixed prosthetic restorations – from temporization to restoration care. The products are
optimally coordinated with each other and enable successful processing and application.

Systemp® IPS e.max® Programat® IPS e.max® Multilink® N Cervitec®

PREPARE RESTORE PROCESS FINISH PLACE MAINTAIN

THESE ARE FURTHER PRODUCTS OF THIS CATEGORY:

Programat ®
IPS e.max System ®

Press and ceramic furnaces for demanding all ceramic – all you need
requirements

Packed with proven technology and The comprehensive solution covering


advanced innovations all indications
• Outstanding press and firing results • Highly esthetic, high-strength materials for the
• Ideally coordinated with the ceramic materials press and CAD/CAM technique
of Ivoclar Vivadent • Unique lithium disilicate (LS ) and zirconium oxide (ZrO ) ceramics
2 2
• Easy operation for restorations ranging from thin veneers to long-span bridges
• Flexibility of cementation: adhesive, self-adhesive and conventional

Would you like to know more about the products of the “Fixed Prosthetics” category? Simply get in touch
with your contact person at Ivoclar Vivadent or visit www.ivoclarvivadent.com for more information.
Descriptions and data constitute no warranty of attributes
Printed in Germany © Ivoclar Vivadent AG

Ivoclar Vivadent AG
Bendererstr. 2
667196/e/2014-02-04

9494 Schaan
Liechtenstein
Tel. +423 235 35 35
Fax +423 235 33 60
www.ivoclarvivadent.com