96M11667 Accessories

■ Amplifier
Mounting bracket: 1 End unit: 2 Instruction Manual: 1
Supplied with LV-11SB (P) Supplied with LV-12SB (P)

Ultra-small Digital Laser Sensor

LV-S Series (Type B)


■ LV-S31 dedicated accessories ■ LV-S41/S41L dedicated accessories
Instruction Manual Mounting bracket: 1 Mounting bracket: 1
Plate nut: 1
M3 x 15 screw: 2
Adjustment screwdriver: 1

■ LV-S62 dedicated accessories


Reflector (R-6L): 1

■ Symbols
The following warning symbols are used to alert you to safety precautions and
to prevent human injury and/or damage to property when using this product.

Warning Failure to follow instructions may lead to injury.


■ LV-S61 dedicated accessories ■ LV-S63 dedicated accessories
Indicates warnings and restrictions that must be followed during Mounting bracket: 1 L-shaped mounting bracket: 1
Important
operations. Plate nut: 1 M4 nut: 3
M2 x 12 screw: 2 M4 x 30 screw: 3
Note Reflector (R-6): 1 Reflector (R-9): 1
Provides additional information on proper operations that can be easily mistaken.

Safety Information for LV-S series

• This product is just intended to detect the object(s). Do not use this
Warning product for the purpose to protect a human body or a part of human
body.
• This product is not intended for use as explosion-proof product. Do not
■ LV-S71/S72 dedicated accessories
use this product in hazardous location and/or potentially explosive Mounting bracket: 2 Nut: 4 Beam axis adjustment cap: 1
atmosphere.
Facing ring: 2
Washer: 2
Safety precautions on laser products

• Use of controls or adjustments or performance of procedures


Warning other than those specified herein may result in hazardous radia-
tion exposure. ø30
• This product employs a semiconductor laser for its light source.
• Follow the instructions mentioned in this manual. Otherwise, injury
to the human body (eyes and skin) may result. Identifying Part Names
Precautions on class 1 laser products
• Do not disassemble this product. Laser emission from this product Amplifier
is not automatically stopped when it is disassembled.
• Do not stare into the beam.
■ LV-12SB (P) (Expansion unit)

Sensor head LV-S31/S41/S41L/S61/S71/S72 LV-S62/S63

Wavelength 655 nm 660 nm

Output 290 μW
Connector protection

Extension connector

FDA(CDRH) Part 1040.10* Class 1 Laser Product


Channel selection switch

MODE button
Output indicator lamp
Output indicator lamp
(for control output 1)
(for control output 2)

Dust cover

IEC 60825-1 Class 1 Laser Product


(display settings)
Digital monitor

Manual button
Hold lock bar

cover
SET button

* The classification is implemented based on IEC60825-1 following the


requirements of Laser Notice No.50 of FDA (CDRH).

Safety Measures for the Laser


■ Laser emission stop input
The laser emission can be stopped by selecting the “Laser emission stop” signal ■ LV-11SB (P) (Main unit)
(20 ms or more) from the input functions and inputting it externally.
The emission stops while the signal is being input. The laser beam is emitted in 20 ms Sensor head
after the signal input is canceled. The control output functions according to the
■ LV-S31
received light intensity even while laser emission stop is input.
Operation indicator (red) Transmitting section
Note
When the power is turned on, even when the laser emission stop signal is
F
Receiving section
input, the laser is emitted for about 60 ms for self-diagnostic purpose. FAR indicator (red) J
N
F

JUST indicator (green) N

NEAR indicator (red)

Adjustment trimmer

E LV-S-IM 1
■ LV-S41
4 Install the end units on both ends of
■ LV-S41L the amplifier unit.
Receiving Transmitting
Fasten the screws on the top of the
section section end units (at two positions on both
end units) with the Philips screw-
Operation driver.
indicator
(red) Two end units are
Operation
supplied with an
indicator
expansion unit.
(red)
Receiving Transmitting section OP-26751
section
* The stickers on the right are provided. Attach
■ LV-S61 the sticker on the place near the amplifier unit.
Reflector (accessory)
Operation
indicator (red) ■ Removing the amplifier unit

Transmitting section,
1 Remove the end units.
Receiving section 2 Slide the expansion unit and remove it one by one.

• When installing additional expansion unit, be sure to use the DIN rail and the end units.
■ LV-S62 Important
• Turn off the power when installing or removing the unit.
Transmitting section, Reflector (accessory) • Do not remove the protective cover of the extension connector on the
Receiving section amplifier expansion unit that is added at the end.
• Do not remove the amplifier unit with all added units attached, from the DIN rail.
Spot selection switch
• Verify the operation ambient temperature after additional installation. (“Specifications” page 11)
• Do not use full calibration functions or stability output when the expansion unit of
Operation indicator
the LV-S Series is connected to a device with full calibration functions (such as
(red) FST or PS-T) via external input. Doing so may lead to product malfunctions.

■ LV-S63 Input/Output Circuit Schematic


Reflector (accessory)
Operation ■ Output circuit
indicator (red) LV-11SB/12SB (NPN output type)
Brown *
DC12-24V
Sensor main circuit

Overcurrent protection circuit


Black/white (control output 1/2)
Transmitting section,
Receiving section Load DC5-40V

■ LV-S71 ■ LV-S72 Blue *


0V
Operation indicator (red) Operation indicator (red)
* LV-11SB only
Transmitter Receiver Receiver
Transmitter LV-11SBP/12SBP (PNP output type)
Brown *
DC12-24V
Sensor main circuit

Overcurrent protection circuit

Black/white (control output 1/2)


Transmitting section Receiving section Load
Transmitting section Receiving section
Blue *
The operation indicator works in conjunction with the Output selected at the 0V

channel selection switch. (It does with Output 1 in area detection mode.) * LV-11SBP only
The power of the expansion unit LV-12SB (P) is supplied by the Extension connec-
Mounting the Amplifier Unit tor on the side of the main unit LV-11SB (P). The power wires (brown and blue) of
the main unit and those of the expansion unit are unified inside by the connector.
■ Mounting on a DIN rail ■ Input circuit
1) Align the claw at the bottom of the main body with the (3)
• Not to be used
DIN rail. While pushing the main body in the direction • Light emission stop input Select either one.
of the arrow 1, slant it in the direction of the arrow 2. • External calibration input (switched by the amplifier
(2) • Setting value bank selection input
2) To dismount the sensor, raise the main body • Received light intensity shift input function selection)
in the direction of the arrow 3 while pushing (1)
LV-11SB/12SB (NPN output type)
the main body in the direction of the arrow 1.
■ Installation using the mounting bracket (accessory) (LV-11SB/11SBP only)
DC3.3V
Sensor main circuit

Mount the amplifier unit using the supplied Pink (input)

mounting bracket as shown in the figure. PLC etc.


(Short-circuit current 1 mA max.) Blue *
0V

* LV-11SB only
LV-11SBP/12SBP (PNP output type)
DC12-24V
Mounting bracket M3 screw Brown *
Sensor main circuit

(OP-25431)
■ Connecting several amplifier units PLC etc.

Up to 16 expansion units LV-12SB can be installed to the main unit LV-11SB. Pink (input)
(Short-circuit
1 Remove the protection cover on the side of the
* LV-11SBP only
current 2 mA max.)

main unit.

2 Install the amplifier one by one on the DIN rail.

(2)

(1)
3 Engage the two claws of the expansion
unit with the recesses on the main unit
side until you hear a click sound.

2 E LV-S-IM
Connecting the Sensor Head and the Amplifier Unit LV-S41/S41L
Be sure to use the supplied mounting bracket.
■ How to connect the amplifier unit and the connector
1 Open the dust cover, and tilt the
1 Press the mounting bracket on the sensor head.
Be sure to hook the A portion of the mounting bracket on the B portion of
hold-lock lever.
the sensor head.

2 Raise the hook, and insert the


B

connector to the very end.

2 Install the sensor head on the flat surface with the


M3 screws as shown in the following figure.
3 Lower the hook and (The M3 screw is not an accessory.)
hook the part shown
in the figure, and
then raise the hold-
LV-S62
lock lever.
Mount the sensor head using either L-shaped mounting bracket (OP-84350),
rear mounting bracket (OP-84349), side mounting bracket (OP-84351) sold
Note separately.
When shortening the sensor head cable, follow the instructions given in the ■ L-shaped mounting bracket (sold separately: OP-84350)
“Sensor Head Connector Assembly Procedures” included with the sensor
Mounting bracket 1
head.
Plate nut 1
M3 x 7.3 screw 1
Mounting and Adjusting the Sensor Head
LV-S31
1 Insert the plate nut to the head.

■ Adjusting the trimmer (detection position)


The detection range can be selected as desired by adjusting the trimmer.
When detecting the target When detecting the target
from a long distance, turn the
trimmer clockwise to adjust.
from a short distance, turn the
trimmer counterclockwise to
2 Insert the protrusion on the amplifier for
F
J
F F
J
F
adjust. securing the bracket into the hole at the
N N N N
upper part of the bracket.
Limit the tight-
ening torque
up to 0.5Nm
■ Adjusting the center of detection

1 Place the workpiece at the position you


■ Rear mounting bracket (sold separately: OP-84349)
want to set as the center of detection. Mounting bracket 1
M3 x 18 screw 2
2 Turn the trimmer until JUST
indicator (2) illuminates in green.

When (1) illuminates, turn the


trimmer clockwise until (2)
Limit the tightening
illuminates.
torque up to 0.5Nm
(1) F F
When (2) illuminates, the
(2) J
• Adjusting the beam axis
N N
adjustment is complete.
(3)
(1) The beam axis angle can be adjusted horizontally by swinging the
When (3) illuminates, turn the
trimmer counterclockwise bracket to the left and right with screws (a), (b) and (c) loosened. In order
until (2) illuminates. to tighten the screws, be sure to tighten screw (b) first.
(a) (c)
Finer adjustment is possible by looking at the display on the amplifier (page 9). (a)
(c)
(b) (b)
■ Detecting a height difference
A stable detection is made possible by
adjusting the trimmer so that the middle
(2) The angle of the beam axis can be changed downward if the screw indi-
point of the height comes to the center of
cated by the arrow is tightened, and upward if loosened.
detection.
When you want to lower the beam axis. When you want to raise the beam axis.

Middle point

■ Movement directions of the workpiece

Movement
direction

Important Be sure to adjust the beam axis in the order of (1) and (2).
Detecting Detecting Detecting
object Movement object object Movement
direction
If the order is reversed, the screws in (1) may be damaged.
direction

E LV-S-IM 3
■ Side mounting bracket (sold separately: OP-84351) ■ Maximum sensitivity setting
Mounting bracket 1 Spot toggle Set the sensitivity without a workpiece in the case of the reflective type, and with
M3 x 18 screw 2 switch a workpiece in the case of the transmission type.
Reflective type 1 Press the SET button for three
seconds in the state as shown in
Limit the tightening the figure on the left.
With no workpiece
torque up to 0.5Nm
Note
When mounting the sensor head in the opposite direction as described previ-
ously, set the spot toggle switch before mounting. Transmission type
The indication flashes when the setting
• Adjusting the beam axis
is complete.
The angle of the beam axis can be changed upward if the screw indicated by
the arrow is tightened, and downward if loosened. With workpiece
When you want to raise the beam axis. When you want to lower the beam axis.

2 Release the SET button.


Note
In the transmission type, if the value for the maximum sensitivity setting is the same as
DSC, the device will not operate correctly, so do not use the same value.
■ Full-auto calibration (not available for the LV-S31)

LV-S71/S72
1 Let the workpiece pass while the SET
button is being pressed for three
Mount the sensor head such seconds. (The sensitivity is set
Fixing nut according to the received light intensity
that the letter “T” (on the
transmitter) or “R” (on the while the SET button is pressed.)
receiver) faces upward. The 2 The indication flashes when the
side where the operation indi- setting is complete.
cator illuminates should face
Beam axis Limit the tightening
upward. adjusting screw torque up to 1.2 Nm.

• Adjusting the beam axis 3 Release the SET button.


The angle of the beam axis can be changed downward if the screw indicated MAX
Received light intensity

by the arrow is tightened, and upward if loosened.


When you want to lower the beam axis When you want to raise the beam axis The value is set at the intermediate point
Setting value
between the MAX value and the MIN value
of the received light intensity measured
MIN while the SET button is pressed.
Time

Perform 2-point calibration if the setting cannot be configured as desired.


Adjust the spot to be emitted at the
center on the receiver. ■ Zero datum calibration (not available for the LV-S31)
The adjustment is facilitated by 1 Press the SET button quickly without a
attaching the beam-axis adjustment workpiece being placed.
cap supplied with the sensor head to
the tip of the receiver. Once the
Beam axis
adjustment cap
2 Press the SET button for at least three
seconds. When the indication flashes,
adjustment is complete, remove the release the button.
beam-axis adjustment cap.
3 The calibration is complete when
" " is displayed. When " " is displayed, switch the
Setting Sensitivity
channel toggle switch to "2" and check the contents of the alarm.
■ 2-point calibration *The alarm contents are only displayed when "Auto" is selected for "ALrt",
1 Press the SET button once without a
1 2 the operation of control output 2 in "4. Detection mode selection". (For
workpiece being placed. information about the display, see "Toggling the display" on page 9.)
Transmission/retro-reflective types

Received light
2 Place a workpiece at the designated
intensity without
workpiece Blocked light
position, and quickly press the SET
button once again. Received light Setting value
intensity with
workpiece 0 Received light 0
(Blocked light) intensity without
workpiece
In the transmission or retro-reflective type, when zero datum calibration is performed
without a workpiece, the received light intensity without a workpiece is used as zero and
Received light intensity

2 The value set at the intermediate point the value indicates the amount of blocked light. The setting value is set automatically.
between the received light intensity
Setting value measured when the SET button is pressed Reflective type
1 for the first time and that measured when it
is pressed for the second time. Received light
Time intensity with
workpiece Entered light
* If the sensitivity difference does not have enough room, “++++” flashes after (Entered light)
the calibration is complete. The setting value is changed at this time, too. Received light Setting value
intensity without Received light
workpiece 0 0
intensity without
workpiece
In the reflective type, when zero datum calibration is performed without a
workpiece, the received light intensity without a workpiece is used as zero and the
value indicates the amount of entered light. The setting value is set automatically.

4 E LV-S-IM
Note 2 Short-circuiting the pink wire 20 ms or more as follows for each model is
• The zero datum calibration cannot be used when bank selection (bAnk) is equivalent to pressing the SET button.
set for the control input function. LV-11SB/12SB LV-11SBP/12SBP
Brown* Brown*
• The zero datum calibration can only be used with Output 1. +V +V
• When zero datum calibration is performed on models other than LV-S41/
S41L, the DSC function is turned on.
Blue* Pink
• When zero datum calibration is performed on LV-S41/S41L, the DSC func- 0V
tion is turned off. Pink Blue*
0V
• After zero datum calibration is performed, the minus sign will not be dis-
played. In situations when the minus sign is supposed to be displayed, the * LV-11SB/11SBP only
display stay as zero. * The maximum number of times of writing is one million.
* Input is not accepted while setting any mode (page 7).
■ Positioning calibration (not available for the LV-S31)
Fine-adjusting Sensitivity
1 Press the SET button quickly The setting value can be directly changed by pressing the manual button.
without a workpiece being placed.

2 Place a workpiece on the position


where you want to perform positioning.
Received light intensity

When “five-digit display” is set (page 7, No.11) for the number of dig-
Setting value 3 Press the SET button for at least its to be displayed for the received light intensity
three seconds. When the indication
flashes, release the button. 1 Press the manual button quickly once, and check that the setting value flashes.
Time 2 While the setting value is flashing, change the setting value with the
The sensitivity is set at the point where the value Manual button.
becomes ON exactly when a workpiece comes
to the point where you want to position it.

Note Note
• Output 2 for Bank A and Outputs 1 or 2 for Bank B can be used. When DSC and zero datum are activated, perform fine-adjustment without a
• When the control input function is set to bank select (bAnk), Output 1 on workpiece.
Bank A can be used.
Area Detection Mode
■ % calibration (not available for the LV-S31)
This mode is suited to detecting the received light intensity only of a certain range.
This is a calibration method that can set the setting value by percentage with
reference to the received light intensity at the time of sensitivity setting. For

Received light intensity


To set this mode, select the area
example, if the target value is set to –10P, the setting value is determined 10%
detection mode among the
lower than the received light intensity when the SET button is pressed. OFF
detection modes. (page 7, No. 4,
By regularly performing external calibration from the device such as a PLC,
or page 8 No. 5) Setting value 1
even a little sensitivity difference can be steadily detected. (Upper limit)
The display of the setting values ON
Note
of the upper and lower limits can Setting value 2
The % calibration function cannot be used when the DSC function is turned (Lower limit)
be switched with the channel
on or the zero datum calibration is being used. OFF
selection switch.
1 When selecting the sensitivity 1: Setting value upper limit
setting method (page 7, No. 5), 2: Setting value lower limit
select the % calibration, and set
the target value of calibration.
(The value can be set by 1%.) Keep the range of setting value 1 > setting value 2.
Nothing is detected when setting value 1 ≤ setting value 2.
2 Taking the desired light intensity as Output 2 cannot be used while the area detection mode is in use.
a reference (normally without a
workpiece), press the SET button. ■ Sensitivity setting method 1 (Normal sensitivity)

1 Place a workpiece on the upper


limit of the received light intensity
* While the % calibration is in use, other calibrations (sensitivity setting) can- that you want the sensor to detect,
and press the SET button once.
not be used.
* The setting value is calculated based on the intermediate value between
MAX. and MIN. of the received light intensity while the SET button is being 1: Upper limit
pressed. The conditions in acquiring the sampling value can be changed
using the procedure to set the special modes. 2: Lower limit
2 Place a workpiece on the lower limit
of the received light intensity that
■ Edge detection (not available for the LV-S31) you want the sensor to detect, and
Detects the change in the received light intensity during a given period of time. press the SET button once again.
In the detection mode (page 7, No. 4), select the following edge detection If the sensitivity difference does not have enough room, “+++” flashes after
mode and the detection time. the calibration is finished. The setting value is changed at this time, too.
Rising detection Detects the increase (rising edge) of ■ Sensitivity setting method 2 (when % calibration is selected)
the received light intensity
Falling detection Detects the decrease (falling edge) of
the received light intensity 1 Place a workpiece on the
designated position, and press the
Rising/falling Detects both the rising and falling
(both-edge) detection edges of the received light intensity. SET button once.

Sensitivity setting
The sensitivity is set to maximum when the SET button is pressed once.
(If the SET button is pressed and held for a while, changes in the light intensity dur-
Specify the setting values to the
ing that period are ignored.)
upper and lower limits of the time
Output status
when you press the SET button.
Setting Operation
L-ON Always OFF. Turns ON only when the light intensity changes. Example: When the setting value of the % calibration is set to 10P
D-ON Always ON. Turns OFF only when the light intensity changes.
The value that is the received light intensity when the SET button is pressed
plus 10% is set for the setting value 1, and minus 10% for the setting value 2.
■ External calibration ■ Bank function
1 Select the external calibration with the menu switch. Normally, up to two setting values can be set, but by using the bank function,
up to four setting values can be set.

E LV-S-IM 5
Note • When connected to LV-S41/S41L, the DSC function turns off when the zero datum
The zero datum calibration cannot be used when using the bank function. calibration is performed and operates while turned on when there is entered light.
■ Alarm output level (ALrt) setting
1 When selecting the control input function (page 7, No.8, or page 8, No. 7), Specify the operation for control output 2 when the DSC function is set to ON.
select the bank selection. Mode Operation
2 Normal bank A becomes bank B when the external input wire (pink wire) Auto Control output 2 acts as an alarm output.
is short-circuited. uSEr Control output 2 performs a usual operation.
LV-11SB/12SB LV-11SBP/12SBP ■ Alarm output level (rtio) setting
Brown* Brown* Specify the level at which to output an alarm when the received light intensity
+V +V
changes as moderately as the control output stays off (specifying the moder-
ate fluctuation alarm level).
Blue* Pink
0V DSC is not performed during a period when the received light intensity falls
Pink Blue* below the alarm level.
0V
Specified range: 0 to 100%
* LV-11SB/11SBP only 100%: The moderate fluctuation alarm is not output.
Set or change the bank B while the input signal is input. 50%: An alarm is output when the received light intensity changes from the
background state up to half the setting value.
Setting the Display Scaling (not available for the LV-S31) 0%: An alarm is output when the received light intensity gets any closer to
This is the function to adjust the received light intensity during operation to the the setting value from the background state.
“scaling target value”. Note
Note Normally use the setting at 50%. Smaller values can affect the response and
This function cannot be used when zero datum calibration is being used. prevent the alarm from becoming cleared.
Timing chart
Ex: When using a transmission or retro-reflective type

1 When setting a display scaling (page 7, No. 6), select to use the display Received light intensity

scaling, and set the target value. (The explanation here deals with the case rtio Received light intensity
Alarm level
where the target value is set to 2000.)
100%

2 During the normal display, press the SET button while pressing the MODE button. Setting value

Alarm state

Workpiece detection
(no alarm)
Output 1 (Control output)

The display changes as follows, and the target value (which is 2000) to be
set as a scale is displayed. Output 2 (Alarm output)

Shift Function
Forcibly synchronizes the received light intensity with the preset value (shift
↓ target value). (Adds and subtracts the received light intensity.)
The display scaling is performed. Regular synchronization inputs from a PLC or other device stabilizes the
detection of the target that has a little light intensity difference.
Note
The shift function cannot be used when the DSC function is turned on or the
The reference light intensity can be set in the following range in reference with
zero datum calibration is being used.
the currently received light intensity:
Power mode Minimum value Maximum value 1 When setting a shift function (page 7, No. 7, or page 8, No. 6), select to
HSP Approx. 1/20 times Approx. 16 times activate the shift function, and set the shift target value.
The error is indicated LV-11SB/12SB LV-11SBP/12SBP
FINE Approx. 1/40 times Approx. 8 times Brown* Brown*
when the value is out of +V +V
TURBO Approx. 1/80 times Approx. 4 times the range.
SUPER Approx. 1/160 times Approx. 2 times Blue* Pink
ULTRA Approx. 1/320 times Approx. 1 time 0V
Pink Blue*
0V
Special function
After an external calibration, the scaling can be externally performed by * LV-11SB/11SBP only
inputting the signal again in three seconds. * Whether or not to save the current display status changed by an external input
• In the case of the % calibration (example) can be selected in the special mode (See “How to set the special mode” on
%calibration Display scaling
page 9). The default is to “Save”.
Input ON It is recommended that you set “Do not save” when the external input is fre-
Input OFF quently performed. The maximum number of times of writing is one million.
Within 3
seconds
Hold Function
%calibration %calibration
This function holds the peak value and the bottom value of the received light
Input ON
intensity during operation.
Input OFF
3 seconds
At Hold mode selection (page 7, No.9), select the hold mode.
or more
Hold mode Operation
* Input is not accepted while setting any mode. (page 7)
Updates the peak and bottom values every time the current light
intensity exceeds or drops below the specified value.
DSC (Dynamic Stability Control) Displays the maximum and minimum peak values since the
DSC automatically corrects the setting value according to the changes in the power is turned on (total number).
received light intensity when there is no workpiece (output OFF). Displays the maximum and minimum bottom values since the
This function is effective when the light intensity difference is small when power is turned on (total number).
judging whether or not there is a workpiece. At Detection mode selection Displays the minimum peak value and the maximum bottom
(page 7, No.4), select " ".* value since the power is turned on (total number).
How to set the sensitivity is the same as in the normal mode.
Displays the maximum peak value and the minimum bottom
* The value is stored in memory even after the power is turned off.
value since the power is turned on (total number).
Note
• When connected to a sensor head other than LV-S31/S41/S41L, the DSC func-
tion turns on automatically when the zero datum calibration is performed and
operates while turned on when there is blocked light. When other calibrations are
performed in this state, the DSC function is turned off.

6 E LV-S-IM
How to Set up Each Mode (Models other than LV-S31)
Selecting the correction speed
The settings of Output 1 and 2 can be divided into common settings and indi- Press the or button to select.
vidual settings depending on the modes. Change the mode by using the The correction is made faster as
channel selection switch. To exit the mode setting while it is not completely the number becomes larger (1 to 3).
(Select 1 for normal cases.)
finished, press the MODE button for over 2 seconds. Refer to page 8 when MODE
Mode LEv1 LEv2 LEv3
using the LV-S31.
Correction 104.86s 1.64s 25.6ms
speed

MODE Selecting the operation for control output 2


Press for two seconds Press the or button to select.
or more • Uses normal operations for
1 Selecting output MODE
Output 1/2 individual setting control output 2.
• Uses alarm output for control
Press the or button to select.
MODE output 2.
• Turns ON while the light enters.
• Turns ON while the light is shielded.
Setting the range for alarm output level
Press the or button to select.
Set in the range between 0 and 100P.
2 Selecting the power mode (response time)
When zero datum
Output 1/2 common * Normally use the setting at 50%.
calibration are selected
Press the or button to select.
B
• HIGH SPEED:80 µs MODE C
• FINE:250s
• TURBO:500s 5 Selecting the sensitivity selecting method
When Output 2 is Output 1/2 common
• SUPER:2 ms set, Alarm output is MODE When % Press the or button to select.
• ULTRA:4 ms selected, and calibration
"Auto" is selected • Normal sensitivity setting
When the power mode is changed, redo the calibration. is selected
• % calibration
* Cannot be selected when LV-S62/S63 is being used.

Setting the target value of the %


C calibration
MODE Press the or button to select.
From –99% to +99% can be set.

End of the basic


menu display 6 Setting the display scaling
Output 1/2 common
MODE Press the or button to select.
When OFF When ON is
3 Selecting the Timer mode selected • Normal display
is selected
Output 1/2 individual setting • Display scaling
MODE Press the or button to select.
• Timer OFF Setting the display scaling target value
• OFF delay Press the or button to select.
When zero datum
When Timer When other • ON delay calibration or % or It can be set by the unit of 100.
OFF setting than • One-shot DSC
is selected Timer OFF calibration is selected
• ON delay, OFF delay *1
is selected
• ON delay, one-shot *1 B
7 Setting the shift function
Timer setting Output 1/2 common
Press the or button to select. MODE Press the or button to select.
When OFF When ON is
MODE
Can be set between 0.1 and 5000 ms. selected • Do not use shift
is selected
When *1 is selected, the ON delay • Use shift
timer is activated.
B Setting the shift target value
When selecting a timer mode,
a If other setting than *1 is selected → a Press the or button to select.
b If *1 is selected → b MODE It can be set by the unit of 1.

Timer setting 2
Sets an OFF delay (one-shot) time. 8 Selecting the control input function
OR Press the or button to select. Output 1/2 common
Can be set between 0.1 and Press the or button to select.
5000 ms. MODE
• Does not use the control input
MODE • External calibration
• Bank selection
When Output 1 is set • Laser emission stop
and zero datum A
calibration is selected (If the sensor head is “LV-S41/S41L” B )
9 Selecting the hold function
Output 1/2 common
4 Selecting the detection mode
Press the or button to select.
Output 1/2 individual setting*
• Updates the peak/bottom value every time that the
Press the or button to select. MODE
current light intensity is less than or more than the set value
• Normal (light intensity) mode
When Output 2 When a mode When a mode When a mode other • Displays the maximum and minimum peak values
• Area detection mode
is set. Normal or DSC is than Normal, DSC, since the power was turned on (total number)
Area detection selected. • Area detection mode
or Area detection • Displays the maximum and minimum bottom values
is selected. is selected • Detects the rising edge of the received light intensity.
since the power was turned on (total number)
• Detects the falling edge of the received light intensity.
MODE MODE • Displays the minimum peak value and the maximum
When zero When a mode DSC is • Detects both the rising and falling edges
bottom value since the power was turned on (total number).
datum calibration selected for Output 1 of the received light intensity
is selected for and a mode Normal is The % calibration function cannot be used when the • Displays the maximum peak value and the minimum bottom
Output 1 selected for Output 2 DSC function is turned on or the zero datum value since the power was turned on (total number).
calibration is being used.
The shift function cannot be used when the DSC
function is turned on or the zero datum calibration is
being used. 10 Selecting the display mode
Output 1/2 common
Selecting the derivation time Press the or button to select.
B C MODE
Press the or button to select. • Normal screen display mode
The time can be selected from 0.25/0.5/1/2.5/ • Full screen display mode
B 5/10/25/50/100 ms. (The available times vary
depending on the power mode.) When DSC mode,
A display scaling,
or zero datum 11 Selecting the number of digits of light intensity display
Output 1/2 common
Selecting the detection operation calibration are
Press the or button to select. MODE
selected Press the or button to select.
• L-on Mainly for reflective type • Four-digit display (the setting value is also displayed)
[light intensity with workpiece > • Five-digit display
light intensity without workpiece]
(The output is on when the light
enters) End program
• d-on Mainly for thrubeam type * When Area detection mode is selected in "4.Selecting the detection mode", "----" is displayed in
[light intensity with workpiece < the Output 2 setting and Output 2 cannot be selected.
light intensity without workpiece] If a mode other than the Normal/Dsct Area detection mode is selected for either Output 1 or 2, the
(The output is on when the light setting of item 5 or 6 or 7 cannot be selected for both Output 1 and 2.
is blocked.)

E LV-S-IM 7
How to Set up Each Mode (LV-S31)
The settings of Output 1 and 2 can be divided into common settings and indi-
vidual settings depending on the modes. Change the mode by using the
channel selection switch. To exit the mode setting while it is not completely
6 Setting the shift function
finished, press the MODE button for over 2 seconds. Output 1/2 common

When OFF MODE When Press the or button to select.


is selected ON is • Do not use shift.
selected • Use shift.
MODE
Press for two
seconds or more
1 Selecting output Setting the shift target value
Output 1/2 individual setting Press the or button to select.
Press the or button to select. MODE It can be set by the unit of 1.
MODE
• Turns on the output nearer to the sensor.
• Turns on the output farther to the sensor.
7 Selecting the control input function
2 Selecting the power mode Output 1/2 common
Output 1/2 common Press the or button to select.
MODE
Press the or button to select. • Does not use the control input
• Normal mode MODE • External calibration
• High-speed mode (response time 250 µs) • Bank selection
• Laser emission stop

When Std is selected When


3 Selecting the response time HSP is
Output 1/2 common selected 8 Setting the hysteresis mode
Press the or button to select. Output 1/2 common
Varies depending on the power mode. Press the or button to select.
MODE
SPEED Response time MODE
• Hysteresis: small
1 500µs • Hysteresis: large
2 2ms
3 8ms
4 32ms
When the power mode is HSP, the
response time is fixed to 250 µs.
(End Program)

* Output 2 cannot be used when the Area detection mode is selected.


If a mode other than the Normal/Area detection mode is selected for either Output 1 or 2, the
setting of item 5 or 6 cannot be selected for both Output 1 and 2.

End of the basic


menu display

How to set up special modes


4 Selecting the timer mode
Output 1/2 individual setting
■ When using a model other than LV-S31
MODE Press the or button to select.
• Timer OFF
• OFF delay
When Timer When other • ON delay MODE SET
OFF setting than
is selected Timer OFF • One-shot Press , , and for three seconds or more at the same time.
is selected • ON delay, OFF delay *1
• ON delay, One-shot *1
Selecting the Power saving function (Eco mode)
Press the or button to select.
Timer setting • Normal use
Press the or button to select. MODE
• Eco-half
MODE Can be set between 0.1 and 5000 ms.
• Eco-all
When *1 is selected, the ON delay timer is
activated.

Selecting the memory of value set by an


When selecting a timer mode, external input while using the shift function
a
If other setting than *1 is selected → a
If *1 is selected → b Press the or button to select.
b MODE
• Saves the value *1
Timer setting 2 • Does not save the value (clears data at power-off)
*1 Data can be saved up to one million times.
Sets an OFF delay (one-shot) time.
OR Press the or button to select.
Can be set between 0.1 and 5000 ms. Selecting the acquisition of the sampling
value* (received light intensity)
MODE Press the or button to select.
MODE • Use the average value from sampling
• Use the peak value from sampling
• Use the bottom value from sampling
5 Selecting the detection mode * Used during % calibration or display scaling.
Output 1/2 individual setting
Selecting the shift function input time
Press the or button to select.
MODE Press the or button to select.
• Normal detection mode MODE
• 5ms
• Area detection mode
• 20ms
The input time is fixed to 20 ms for all other functions.

Switching zero datum settings


Press the or button to select.
• Standard
• Hight-accuracy
* When Hi (High-accuracy) is selected, the width for the zero
datum setting value becomes smaller. During this state, be
especially aware of shocks and other causes of fluctuation.

(End Program)

8 E LV-S-IM
■ When using the LV-S31
When zero datum calibration is selected
MODE
Press
MODE SET
Press , , and for three seconds or more at the same time.
Current value after Current value after Output status Power mode
zero datum calibration zero datum calibration
Selecting the Power saving function (Eco mode) MODE MODE
Press the or button to select. Press Press
MODE • Normal use
• Eco-half
• Eco-all Flashes
Margin*1 Current value before alternately
zero datum calibration
Selecting the memory of value set by an
MODE
external input while using the shift function Peak value Bottom value
Press margin margin*3
Press the or button to select.
MODE
• Saves the value *1 MODE

• Does not save the value (clears data at power-off) Press


*1 Data can be saved up to one million times. Current value before Current value before
zero datum calibration zero datum calibration
MODE
Selecting the shift function input time Press MODE
Press the or button to select. Flashes
Press alternately
MODE
• 5ms
• 20ms
The input time is fixed to 20 ms for all other Bar display*2 Current value after Peak value before Bottom value before
zero datum calibration zero datum calibration zero datum calibration
functions.
*1 The received light intensity is displayed in percentage with reference to
(End Program) the setting value.
*2 Its stability is indicated between 85 to 115 %. The number is varied by
Toggling the Display the unit of 5 %.
*3 The peak- and bottom-hold values since the power-on are displayed.
■ When using a model other than LV-S31
The hold values can be reset by pressing the manual button.
• When "duAl" is selected for the number of digits of light intensity dis-
play and "Std" is selected for display mode • When "rE" is selected for the number of digits of light intensity display
When zero datum calibration is not selected MODE

MODE
Press
Press Flashes
Peak-hold value alternately
Current value
Setting value Current value Margin Current value
Bottom-hold value
When zero datum calibration is selected
MODE
Press ■ When using the LV-S31

Setting value Current value Margin Current value Setting value Current value
after zero datum before zero datum MODE
calibration calibration (1)
Press
When "Auto" is selected for the operation of control output 2 and (3) Peak value Bottom value
the channel setting is switched to "2" MODE
Press Flashes
When zero datum calibration is completed without errors
alternately
(The display shown to the left appears after " " is
displayed during zero datum calibration) Position display

(2) MODE
Press
When zero datum calibration is completed with errors
(The display shown to the left appears after " " is
displayed during zero datum calibration)
(1) Digital display (The position of the target from the center position
Alarm contents* [5000] is displayed in number.)
* The displayed number indicates the following type of alarm.
Outside of the detection range
For more information about remedies to errors, see "Error indication" on page 10.
1: Over DSC correction limit The workpiece is near the sensor with reference
2: DSC small fluctuation detection to the digital display range.

3: Invalid DSC EEPROM contents With 5000 being the middle, the value
4: Over fluctuation width during zero datum calibration increases as the distance from the sensor increases.
5: DSC speed limit alarm The workpiece is far from the sensor with reference to
the digital display range.
• When "duAl" is selected for the number of digits of light intensity dis-
play and "FuLL" is selected for display mode Outside of the detection range
When zero datum calibration is selected
MODE
Press (2) Position display (The position of the target with reference to the
center position is displayed.)
Setting value Current value Output status Power mode
MODE MODE
Outside of the detection range
Press Press

The number of bars increases as the distance from


the sensor increases, taking the state of "A" as the
Flashes
center.
alternately
When adjusting the center position with the trimmer
Margin*1 Current value Peak value Bottom value A on the sensor head, adjust it to the state of "A".
margin margin*3

MODE MODE
Press Press
Outside of the detection range

MODE
Press Flashes (3) The peak/bottom hold value since the power is turned on is displayed.
alternately
Pressing the Manual button can reset the hold value.
Bar display*2 Current value Peak value Bottom value*3

E LV-S-IM 9
Interference Protection Function Caution on a lustrous workpiece (LVS31)
The LV-S Series can prevent mutual interference by connecting amplifier units. If the workpiece is lustrous, the trimmer adjustment may not succeed or
detection may be unstable. In such a case, install the sensor slightly tilted.
■ When using a model other than LV-S31
Power mode HSP (HIGH SPEED) FINE/TURBO SUPER/ULTRA

Number of units required to Unavailable 2 units 4 units


prevent interference

■ When using the LV-S31


Power mode HSP (HIGH SPEED) STD

Number of units required to 2 units 4 units


prevent interference

Keylock
Error Indication
You can lock the operation buttons to prevent the settings from being
changed by careless operation of the buttons. The following indications on the LCD display show the error events. Correct
Setting operations for sensitivity or modes are disabled during keylock, but the problem using the following countermeasures.
the display can be switched. Error indication Cause Remedy
While pressing the
MODE button, press ErH Sensor head is not
connected.
• Check that the sensor head is
connected.
the or button for Head cable is broken. • Check that the head cable is
at least three seconds. not broken.
• Check the connection of the
head cable to the connector.
The indicator shows that key- • After checking these points,
lock is activated. turn on the power again.

• The same steps can be taken to deactivate keylock.


ErC Overcurrent flows through
the output wire.
• Check the load and reduce
the current to be within the
rated range.
Power-save (Eco Mode) • Check that the output wire
The numerical display disappears, and the current consumption is reduced. does not touch another wire or
If a key operation is performed during the Eco mode, the display returns to a frame.
normal. If no more key operation is performed for 4 seconds, the display
returns to the Eco mode. ErE Data write/read error

Data has been written in


• Perform initialization.

• If you need to write more data,


the EEPROM more than replace the amplifier unit.
Cautions on Installing the Reflector (LV-S61/S62/S63) one million times and can
no longer be updated.
Be sure to install the reflector so that it is vertical or horizontal against the sen-
sor unit.
The following table shows the alarms when "Auto" is selected for the operation
of control output "2"and channel setting is switched to "2". Refer to the follow-
ing table to remedy the alarms.
Display Alarm contents Remedy

Over DSC correction limit: Change the setup conditions or


Received light intensity replace the sensor, and secure
during OFF exceeds the the correct received light
DSC correction limit. intensity during OFF.

DSC small fluctuation Move the workpiece to the


detection: correct position.
There are fluctuations
within the range for the
If the reflector is installed diagonally against the sensor unit, the received light alarm output level (rtio).
intensity will decrease significantly.
Invalid DSC EEPROM Restart the power or initialize.
contents:
Failed to write data to
EEPROM.
Over fluctuation width during Take anti-vibration measures in
zero datum calibration: order to suppress fluctuations
The fluctuations of during calibration.
received light intensity
during calibration are too
large.

DSC speed limit alarm: • Move the workpiece to the


The received light intensity correct position.
fluctuated a large amount • Take anti-vibration measures
in a short period of time. in order to suppress
fluctuations in the received
light intensity.

10 E LV-S-IM
Specifications
■ Sensor head
Shearing machine Distance setting Reflective, side Straight beam,
Reflective type Area retro-reflective Transmission type
type type view type retro-reflective type
Model LV-S31 LV-S41 LV-S41L LV-S61 LV-S62 LV-S63 LV-S71 LV-S72
Visible light semiconductor laser Visible light semiconductor laser
Light source Visible light semiconductor laser Wavelength 655 nm Output 290 μW Wavelength 660 nm Wavelength 655 nm
Output 290 μW Output 290 μW
FDA (CDRH) Class 1 Laser Product
Part1040.10
IEC 60825-1 Class 1 Laser Product
ULTRA :
ULTRA : 500 mm ULTRA : 400 mm ULTRA : 2000 mm ULTRA : 30m
50 to 200 mm SUPER : 400 mm SUPER : 320 mm SUPER : 1500 mm 10m (5m) *1
SUPER : 25m
Detecting range (Adjustment TURBO : 300 mm TURBO : 240 mm TURBO :1000 mm SUPER : 8m (3.5m)*1 500 mm
range) FINE : 200 mm FINE : 160 mm FINE : 750 mm TURBO : 15m
HSP : 150 mm HSP : 120 mm HSP : 500 mm TURBO : 5m (2m)*1 FINE : 8m
FINE : 2.5m (0.7m)*1
Switch with two levels:
Approx. 2 x 10 mm / Approx. 8 x 12 mm Approx. ø6 mm
Spot diameter Approx. ø2 mm Approx. ø1.2 mm Approx. ø1.2 mm Approx. ø2.5 mm Approx. 2 x 2 (within 3.5 m Approx. ø1.2 mm (with 500 mm
(within 500 mm distance) distance)
distance)
Operation
indicator lamp
Red LED x 1 Operation indicator lamp
Beam axis Operation indicator lamp Red LED x 1
Indicator adjustment Red LED x 1 (one on each of the transmitter and
indicator lamp receiver)
Red LED x 2,
Green LED x 1
When spot 2 x 10 Opaque object of
mm is selected: ø1.0 mm
2 x 10mm, (detection distance 0
0.5-mm-thick to 100 mm)
transparent glass 8 x 12 mm,
0.5-mm-thick Opaque object of
Opaque object
Standard detecting 100 mm … blank (no AR coated)*2 Opaque object of ø0.8 mm
object 2 mm … blank paper of transparent
ø1.5 mm (detection distance
paper ø2.5 mm glass (no AR
When spot 2 x 2 mm 100 to 250 mm)
is selected: coated) *2 Opaque object of
2 x 2mm, ø0.8 mm
0.5-mm-thick opaque (detection distance
glass*2 250 to 500 mm)
Operating ambient 0 to +50 °C -10 to +50 °C (No freezing)
temperature (No freezing)
Operating ambient light Incandescent lamp : 10,000lx Sun light 20,000lx
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude in the X, Y, and Z directions, 2 hours respectively
Housing Glass reinforced resin
material Metallic section: SUS304
Display Resin section: Polyarylate
Polycarbonate Polyarylate Polycarbonate
section
Transmitter lens: Transmitter lens:
Norbomenic
Lens Norbornenic Norbornenic resin Norbornenic resin
resin Acrylic resin Acrylic resin
Material section resin Receiver lens: Receiver lens:
Polyarylate Polyarylate Glass
Cable PVC
Mounting SUS304
bracket
Reflector - - - Polycarbonate, Acrylic resin - -
(R-4, R-6L, R-9)
Weight Approx. 75 g Approx. 70 g Approx. 70 g Approx. 65 g Approx. 110 g Approx. 70 g
*1 When Spot 2 x 10 mm is selected (Values inside the parentheses ( ) indicate when Spot 2 x 2 mm is selected)
*2 When detecting a transparent glass object, install and set the LV-S63 so that the received light intensity without the glass object becomes 1000 or more.

■ Amplifier
Shearing machine type Main unit Expansion unit
NPN output LV-11SB LV-12SB
Model *1
PNP output LV-11SBP LV-12SBP
Sensor head LV-S Series (LV-S31 / S41 / S41L / S61 / S62 /S63 / S71 / S72)

HSP : 80 μs Only when using the LV-S31


FINE : 250 μs When the detection mode is HSP: Response time 250 μs
Response time *2 TURBO : 500 μs When the detection mode is STD
Speed 1 2 3 4
SUPER : 2 ms
ULTRA : 4 ms Response time 500μs 2ms 8ms 32ms

NPN (PNP) open collector x 2ch


Control output 40 VDC (30 V) max
100 mA max per output
Light emission stop input/external calibration input/Setting value bank selection input/received light intensity shift input
Control input
Input time (other than shift input) 20 ms fixed, (shift input) 5 ms/20 ms selectable
Power voltage *3 12-24 VDC, Ripple (P-P): 10% max, Class2
Rating Current Normal: 1.7 W max. (140 mA max. at 12 V, 70 mA max. at 24 V)
consumption Eco-all/Eco-half: 1.55 W max (130 mA max. at 12 V, 65 mA max. at 24 V)
Operating ambient
-10 to +50 °C (No freezing)
temperature *4
Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude in the X, Y, and Z directions, 2 hours respectively
Material Housing material: Polycarbonate
Weight (including
Approx. 80 g
cable)
*1 The model with B (BP) at the end of the name has additional functions such as zero datum function.
The LV-S62/S63 operates normally only with an amplifier unit that has B (BP) at the end of the model name.
The LV-S31/S61 operates normally only with an amplifier unit that has A (AP) or B (BP) at the end of the model name.
*2 The response time during Edge detection mode is the detection mode set on Page 7. Also, when one side of the output is used for Edge detection mode while HSP mode
is selected, the response time is 125 μs even when Normal detection or Area detection modes are selected. LV-S62/S63 does not handle HSP mode.
*3 When you connect eight or more amplifiers, limit the power voltage to 24 VDC ripple (P-P) 10 %.
*4 When several units are connected, the operating ambient temperature varies depending on the number of units to be connected. When connecting several units, be sure to
mount the units on the DIN rail (mounted on a metal plate), and keep the output current at 20 mA or less.
When 1 to 2 units are connected : -10°C to +50°C
When 3 to 10 units are connected : -10°C to +50°C
When 11 to 16 units are connected : -10°C to +45°C

E LV-S-IM 11
Default Mode Settings (Initialization) WARRANTIES AND DISCLAIMERS
(1) KEYENCE warrants the Products to be free of defects in materials and
Model LV-S41 (L)/S61/S62/S63/S71/S72 LV-S31 workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were
Control output L-on no
used merely to illustrate the general type and quality of the Products and
Operation mode ---- Std (standard) not to represent that the Products would necessarily conform to said
Power mode FinE ---- models or samples. Any Products found to be defective must be shipped
to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE
Response time ---- 4
for inspection and examination. Upon examination by KEYENCE,
END/FULL END END KEYENCE, at its sole option, will refund the purchase price of, or repair or
Timer mode toFF toFF replace at no charge any Products found to be defective. This warranty
does not apply to any defects resulting from any action of Buyer, including
Detection mode Std (standard) Std (standard)
but not limited to improper installation, improper interfacing, improper
Sensitivity setting method Std (standard) ---- repair, unauthorized modification, misapplication and mishandling, such
Display scaling oFF ---- as exposure to excessive current, heat, coldness, moisture, vibration or
outdoors air. Components which wear are not warranted.
Shift function oFF oFF
(2) KEYENCE is pleased to offer suggestions on the use of its various
Control input function oFF oFF Products. They are only suggestions, and it is Buyer's responsibility to
Hold function Std (standard) ---- ascertain the fitness of the Products for Buyer’s intended use. KEYENCE
will not be responsible for any damages that may result from the use of the
Hysteresis setting ---- LEV2
Products.
Display mode Std (standard) ---- (3) The Products and any samples ("Products/Samples") supplied to Buyer
Displayed digits of received light intensity duAl (four digits) ---- are not to be used internally in humans, for human transportation, as
safety devices or fail-safe systems, unless their written specifications
Power saving function oFF oFF
state otherwise. Should any Products/Samples be used in such a manner
Memory function YES (save) YES (save) or misused in any way, KEYENCE assumes no responsibility, and
Sampling value Std (average) ---- additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless
from any liability or damage whatsoever arising out of any misuse of the
Shift function input time 20 (ms) 20 (ms)
Products/Samples.
Zero datum Settig Std (standard) ---- (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
Setting value 1/2 50 5000 PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL
EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING,
WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY,
■ Resetting to the factory default settings FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT
1 While pressing the MODE button, press the left side of the Manual button OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
five times. “ ” is displayed. IN NO EVENT SHALL KEYENCE AND ITS A FFILIATED ENTITIES BE
LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT,
INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES
(INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING
FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF
INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF
PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
2 Press the Manual button, and select “ “. SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR
ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE
3 Press the MODE button or the SET button. OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE
The sensor returns to the default state. OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD
PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST
Tips on Correct Use BUYER. In some jurisdictions, some of the foregoing warranty disclaimers
or damage limitations may not apply.
• To extend the amplifier unit cable, use the cable with the nominal cross-
sectional area no less than 0.3 mm2, and with the length no more than 100
m. (Contact your nearest KEYENCE office when in the event of additional BUYER'S TRANSFER OBLIGATIONS:
installation.) If the Products/Samples purchased by Buyer are to be resold or delivered
• Separate the wiring of the sensor cable from the power line or the high volt- to a third party, Buyer must provide such third party with a copy of this
age line, since the use of these lines in the same pipe generates noise,
document, all specifications, manuals, catalogs, leaflets and written
which may cause malfunction or product breakdown.
information provided to Buyer pertaining to the Products/Samples.
• If you use a commercially available switching regulator, be sure to ground
the frame GND terminal and the GND terminal. E 1110-2
• Do not use the LV-S Series at a location where external light directly falls on
the light-receiving surface.
• When setting the sensitivity, the detection distance may vary depending on
the individual characteristics.
• If you wire the unit incorrectly, the LV-S Series may become hot, or the sen-
sitivity may change.
• Do not connect the sensor head connector to the amplifier unit more than
100 times.
• Displayed values may slightly change depending on the environment (tem-
perature shift, dust, etc.).

2011
11666E 1041-1 96M11667