Documente Academic
Documente Profesional
Documente Cultură
RE 5200CT
RE-5200CT
(Configuration Tool)
Operating Manual
1|Page
RE-5200CT Operating Manual
PREFACE
This operating manual gives the complete guidelines about the RE-5200CT [Addressable
configuration Tool].
2|Page
RE-5200CT Operating Manual
Table of Contents
INTRODUCTION ..................................................................................................................... 5
Installation.................................................................................................................................. 5
Installation Prerequisites ........................................................................................................ 5
Hardware Prerequisites ....................................................................................................... 5
Connection Methods ........................................................................................................... 6
Additional Software Prerequisites ...................................................................................... 6
RE-5200CT Configuration Tool Installations ........................................................................ 6
To install RE-5200CT (Addressable configuration Tool) .................................................. 6
Uninstalling RE-5200CT Applications .................................................................................... 15
To uninstall RE-5200CT Configuration tool and its components........................................ 15
Programming Operations ......................................................................................................... 15
Using windows on the project .......................................................................................... 15
Login window ...................................................................................................................... 15
Using commands on the menu bar Project Window: ........................................................... 16
File Menu ............................................................................................................................. 17
Creating a new project ...................................................................................................... 18
Opening an existing project .............................................................................................. 18
Password Change .............................................................................................................. 19
Main Window .......................................................................................................................... 20
Add Panel ............................................................................................................................. 20
Project Panel Options ........................................................................................................... 21
Panel Configuration ................................................................................................................. 21
System .................................................................................................................................. 22
Settings ............................................................................................................................. 22
Relay Output ..................................................................................................................... 22
Night Mode ....................................................................................................................... 23
Loop Card ............................................................................................................................. 24
Step1: Select the Loop card On the Loop Card Tab. ........................................................ 24
Step2: Set Loop Card Status and Style ............................................................................. 24
Step3: Read a LoopCard data from a Panel. ..................................................................... 24
Step4: Add a devices to a panel ........................................................................................ 25
Step5: Update a Data to a Panel ....................................................................................... 26
3|Page
RE-5200CT Operating Manual
4|Page
RE-5200CT Operating Manual
INTRODUCTION
This user manual intends to guide the RE-5200CT operations. This tool is based on
the USB. This RE-5200CT tool is used to configure and Backup the configuration
data of the Addressable Panel. User operating Instructions are provided in this
manual.
GENERAL:
RE-5200CT tool is based on the COM port. All Information from the Addressable
panel is configured via COM Port. The Configuration Information from the
Addressable Panels is received & Send by the RE-5200CT tool.
Installation
This installation provides information about the installation of Configuration tool.
Installation Prerequisites
RE-5200CT Configuration Tool requires the following to properly interface with and
configure an Addressable Fire Alarm System.
Hardware Prerequisites
5|Page
RE-5200CT Operating Manual
Connection Methods
Configuration Tool has a one click installer that searches for and if needed, will install
the following applications.
6|Page
RE-5200CT Operating Manual
2. Click Next
3. Click Install
7|Page
RE-5200CT Operating Manual
8|Page
RE-5200CT Operating Manual
Installing Dfuse
9|Page
RE-5200CT Operating Manual
10 | P a g e
RE-5200CT Operating Manual
ATTENTION:
The user installing Configuration tool must have Administrator rights.
Windows 7 and 8 Users.
If you receive Program Compatibility Issue click Run Program.
3. After installing the additional required applications, the Configuration tool setup
screen will appear. Click Next.
11 | P a g e
RE-5200CT Operating Manual
4. To install this Folder Click Next, To install to a different folder Click Browse
12 | P a g e
RE-5200CT Operating Manual
13 | P a g e
RE-5200CT Operating Manual
7. Click Next.
14 | P a g e
RE-5200CT Operating Manual
Configuration tool component uninstallation occurs from each application and uninstalls the
applications.
1. From Windows select Start > Control Panel. Double-click Add or Remove Programs.
The Add or Remove Programs dialog box appears.
2. Choose the RE-5200CT application and select Remove. The uninstallation takes a few
seconds.
Note: Uninstall does not remove Prerequisites components. You must manually
Uninstall those components.
Programming Operations
In particular, we created a page that listed the contents of the current directory.
Anyone could visit this page, but only authenticated users could view the files’
contents and only authorized user could delete the files.
15 | P a g e
RE-5200CT Operating Manual
This section describes the projects of the Configuration Tool, its include Menu Bar.
Main Window
This section describes the Main window of the Configuration Tool, including Menu
Bar, Tabs, and Tree panels.
16 | P a g e
RE-5200CT Operating Manual
File: The file menu provides commands for creating, opening project. (Shortcut = Alt, F)
About: Displays the version number and copyright notice (Shortcut = Alt, A)
File Menu
The file menu provides commands for creating, opening project. To use the file menu
commands,
Click file on the menu bar, and then select the command.
17 | P a g e
RE-5200CT Operating Manual
Use the New command on the file menu to create a new project.
The New Menu is used to create a new Project for particular sites.
The user should be enter all the Necessary information and click the save button.
Opening a project loads the project configuration information into the configuration utility
and starts an editing session.
If there is more than one, select the correct version number, and then click OK. Use the
description in the Description box to help you identify the project.
18 | P a g e
RE-5200CT Operating Manual
Password Change
Password change updates the password for the user in the Soft Connect.
The boxes found on the Password window are described below.
User Name: Specifies the existing user name.
Old Password: Specifies the existing password.
New Password: Specifies the new password.
Confirm Password: Specifies the new password a second time, for confirmation.
19 | P a g e
RE-5200CT Operating Manual
Main Window
Main Window contains Menus and Tree view to represent the Panel.
Add Panel
Site Name
Project Name
Step1: Right Click the Project name and Select the Add Panel Option in the popup Menu.
Step2: Select the edit Menu and Click the Add Panel Option.
20 | P a g e
RE-5200CT Operating Manual
Panel Configuration
21 | P a g e
RE-5200CT Operating Manual
System
It’s contains a 5 sub tabs are Settings, Relay Output’s, Remote Input’s, Advanced.
Settings
Relay Output
22 | P a g e
RE-5200CT Operating Manual
Night Mode
23 | P a g e
RE-5200CT Operating Manual
Loop Card
Note:
Depends upon the Panel Option, Panel Belongs to Loop Sounder or without Loop Sounder
option Based on this option the Device count and Device type differ in LoopCard Option.
With Loop Sounder Max 159 Devices to Configure the Loop Sounder has 128 to 159
addresses.
Status Style
Enable Class A
Disable Class B
1. Do the Step 1.
2. Click Edit button to Enabling the LoopCard information’s.
3. Press the Read Device button it’s automatically read selected LoopCard
Device information from the Panel.
24 | P a g e
RE-5200CT Operating Manual
1. Do the Step 1.
2. Click Edit button to Enabling the LoopCard information’s.
3. There are two ways to add a devices
1. Double Click the cell to add a device. Once you select a device it automatically adds
Default Device information.
2. First select a Cells with help of mouse and select a device name and Click add
click Add devices Button to add a device. For add a multiple address with
same devices using Shift or control key to select address do the same.
25 | P a g e
RE-5200CT Operating Manual
1. Do the Step 1.
2. Click Edit button to Enabling the LoopCard information’s.
3. Do the Step 3 to add a Device.
4. Then click an update button to update Device information to a Panel.
1. Do the Step 1.
2. Click Edit button to Enabling the LoopCard information’s.
3. Do the Step 3 to add a Device.
4. To delete a devices First select device address using mouse click for multiple
select uses Shift /control key then press a Delete button.
5. Then Click the update button its update a panel.
6. To delete all the devices click Delete all button its delete all the Devices from
the checked LoopCard.
7. Then Click the update button, its update to the panel.
1. Do the Step 1.
2. Click Edit button to Enabling the LoopCard information’s.
3. Select the Device to filter, then click the Filter button
26 | P a g e
RE-5200CT Operating Manual
Grouping
Group tab Contains three sub tabs are Zone Grouping, Logic Input and Output
Grouping, View. Groupings are based on the Group number.
Grouping:
Zone Grouping
27 | P a g e
RE-5200CT Operating Manual
9. Then click the update button to update the selected group information to the
panel or if the application in the disconnected mode its saves the information.
10. Do the step 2 for the entire zone grouping.
11. Configured this zone grouping in offline mode once panel connected to the
application then click the update all button to update the entire zone grouping
information to the panel.
28 | P a g e
RE-5200CT Operating Manual
4. Select the Logic number and output number for a corresponding Logic for
a Grouping.
5. Select the Loop Number to add Devices for Both the Grouping.
6. It’s shown all the Input devices and output devices in the Input Devices
List and Output List.
7. While clicking the input devices in the input device list, it’s added and
shown in the Logic grouped device list.
8. While clicking the output devices in the output device list, it’s added and
shown in the output grouped device list.
9. Select the Active count for a Logic Input Group and Output activated for,
Delay seconds, and Status of the Output group.
10. Then click the update button to update the selected group information to
the panel or if the application in the disconnected mode its saves the
information.
11. Do the step 2 for the entire grouping.
12. Configured this grouping in offline mode once panel connected to the
application then click the update all button to update the entire grouping
information to the panel.
Step3: Read a Logic Input & output grouping data from a Panel.
29 | P a g e
RE-5200CT Operating Manual
View
View tab is used for to view the entire configured group Combination and print the
necessary information.
View should show the zone group number with devices and their options.
30 | P a g e
RE-5200CT Operating Manual
31 | P a g e
RE-5200CT Operating Manual
Features
Features contain 5 types of features.
By select a Checkbox for enable status and Enter the Minutes or Seconds for the
corresponding Features. Then click an update button to update a panel.
Event History
32 | P a g e
RE-5200CT Operating Manual
33 | P a g e
RE-5200CT Operating Manual
Report
34 | P a g e
RE-5200CT Operating Manual
Other Features:
Program
Import
By selecting import Option, it‘s open a Open file Dialog Box, User select a
Corresponding file path to Import Data.
35 | P a g e
RE-5200CT Operating Manual
To import a data file should be in the format of Excel (.Xls) file. The File Content in
the format attached to this manual (Excel file).
Sample Excel Sheet Displayed and Given to this Manual. User should add necessary
Device information for corresponding Address and import it.
Make sure the import Excel Sheet format is same as the Export (.Xls) file
Format.
Export
By Selecting Export option lets you to select a Location for save a file. User should
select a Path to save a file. Default File name should be your Panel name.
Export file in the format of Excel sheet (.Xls).its contains all the Panel Configuration
information.
Edit
Edit Menu has a three sub menus are full mode, Add Panel, Panel option.
36 | P a g e
RE-5200CT Operating Manual
Full Mode
Add Panel
Is used to add a new Panel under this Project .Each Project accept only 16 Panels.
Panel Option
Panel Option is used to configure the panel operation as With Loop sounder or with-out Loop
Sounder.
37 | P a g e
RE-5200CT Operating Manual
Communication
Communication Menu contains connects and Disconnect option it’s used to connect a
panel and Disconnect from a panel.
Note:
Once connect the Software to the panel avoid using the panel manually.
After finished the configuration, disconnect the application and Restart the
Panel.
Exit
Exit Menu is used to Exit an application.
38 | P a g e