Product: EXCAVATOR
Model: 330D L EXCAVATOR B6H
Configuration: 330D L Excavator B6H00001-UP (MACHINE) POWERED BY
C9 Engine
Systems Operation
320D, 321C, 323D, 324D, 325D, 328D, 330D, 345C, 365C, 385C, M325D and W345C
Excavators Monitoring System
Media Number -RENR8068-04 Publication Date -01/03/2006 Date Updated -29/03/2006
i02524789
Calibration Mode
SMCS - 7490
S/N - A3R1-UP
S/N - AWN1-UP
S/N - AYF1-UP
S/N - B6H1-UP
S/N - BZN1-UP
S/N - C3N1-UP
S/N - C4H1-UP
S/N - C7K1-UP
S/N - C8L1-UP
S/N - C9M1-UP
S/N - CJM1-UP
S/N - CJX1-UP
S/N - CPX1-UP
S/N - CWG1-UP
S/N - CXY1-UP
S/N - CYD1-UP
S/N - D3D1-UP
S/N - DBH1-UP
S/N - DFP1-UP
S/N - DHK1-UP
S/N - DKW1-UP
S/N - E4K1-UP
S/N - EAH1-UP
S/N - EBY1-UP
S/N - EDC1-UP
S/N - EDF1-UP
S/N - EJC1-UP
S/N - FFK1-UP
S/N - FXK1-UP
S/N - GBH1-UP
S/N - GBR1-UP
S/N - GGE1-UP
S/N - GPB1-UP
S/N - GTN1-UP
S/N - H3K1-UP
S/N - JAR1-UP
S/N - JGZ1-UP
S/N - JJG1-UP
S/N - JKR1-UP
S/N - JLP1-UP
S/N - JLS1-UP
S/N - KBA1-UP
S/N - KBE1-UP
S/N - KCR1-UP
S/N - KDG1-UP
S/N - L2K1-UP
S/N - LEM1-UP
S/N - LWR1-UP
S/N - M3M1-UP
S/N - MCH1-UP
S/N - MCL1-UP
S/N - MDC1-UP
S/N - MDE1-UP
S/N - MEY1-UP
S/N - MKR1-UP
S/N - MWP1-UP
S/N - NBD1-UP
S/N - PHX1-UP
S/N - PKE1-UP
S/N - R5K1-UP
S/N - RAS1-UP
S/N - RFN1-UP
S/N - RJK1-UP
S/N - SCR1-UP
S/N - SDC1-UP
S/N - SYM1-UP
S/N - T2S1-UP
S/N - T2Y1-UP
(15) OK key
Note: Refer to Systems Operation, "Service Mode" for instructions to get to the "SERVICE" menu.
Illustration 2 g01213605
The following is a list of calibrations that can be performed with the monitoring system.
Control Valves
z A1 Valve Extend
z A1 Valve Retract
z A2 Valve Extend
z A2 Valve Retract
z A3 Valve Extend
z A3 Valve Retract
Relief Valves
PS Pres Valve
z Mod L Thumbwheel
z Mod R Thumbwheel
Engine Speed
Fan Speed
Control Valves
Illustration 3 g01213089
1. Main Menu
2. Service
5. Control Valves
When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 1
Step
Operation
Connect the pressure gauge to the pressure tap corresponding to the selected valve. Then
1
press the "OK" key (15) in order to go to the next step.
2 Release all controls then press the "OK" key (15) in order to go to the next step.
Hold the thumbwheel in the forward position while pressing the "OK" key (15) in order to
3
go to the next step.
Hold the thumbwheel in the forward position while tuning the pressure to the target value.
Press the right key (9) or the left key (12) in order to increase or decrease the pressure
4
shown on the pressure gauge. When you finish tuning the pressure to the target value,
press the "OK" key (15) to go to the next step.
5 Repeat step 3.
6 Repeat step 4 for the new target value.
7 Repeat step 2.
8 End of the calibration.
Relief Valves
Illustration 4 g01213209
1. Main Menu
2. Service
4. Calibrations
5. Relief Valves
When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 2
Step
Operation
1 Connect the pressure gauge to the pressure tap corresponding to the selected valve. Then
press the "OK" key (15) in order to go to the next step.
Hold the thumbwheel in the forward position while pressing the "OK" key (15) in order to
2
go to the next step.
Hold the thumbwheel in the forward position while tuning the pressure to the target value.
Press the right key (9) or the left key (12) in order to increase or decrease the pressure
3
shown on the pressure gauge. When you finish tuning the pressure to the target value,
press the "OK" key (15) to go to the next step.
4 Repeat step 2.
5 Repeat step 3 for the new target value.
6 Release all controls then press the "OK" key (15) in order to go to the next step.
7 End of the calibration.
PS Pres Valve
Illustration 5 g01213258
1. Main Menu
2. Service
3. Enter the "SERVICE" password.
4. Calibrations
5. PS Pres Valve
When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 3
Step
Operation
Connect the pressure gauge to the pump pressure tap. Then press the "OK" key (15) in
1
order to go to the next step.
Press the right key (9) or the left key (12) in order to increase or decrease the current
2 value. Tune the pressure to the target. When you finish adjusting then press the "OK" key
(15) to go to the next step.
3 Repeat step 2 for the new target value.
4 End of the calibration.
Perform the following steps in order to calibrate the Flow Limit Valve:
1. Main Menu
2. Service
4. Calibrations
6. Make the desired selection from the Flow Limit Valve screen.
When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 4
Step
Operation
1 Connect the pressure gauge to the appropriate pressure tap. Then press the "OK" key (15)
in order to go to the next step.
Move stick to full in position then press the "OK" key (15) in order to go to the next step.
2
Hold stick in the full in position then press the "OK" key (15) in order to go to the next
3
step.
Hold the stick in the full in position while tuning the pressure to the target value. Press the
right key (9) or the left key (12) in order to increase or decrease the pressure shown on the
4
pressure gauge. When you finish tuning the pressure to the target value, press the "OK"
key (15) to go to the next step.
5 Repeat step 3.
6 Repeat step 4 for the new target value.
7 End of the calibration.
Lever/Pedal/Atch
Illustration 7 g01213413
Perform the following steps in order to calibrate the right and left thumbwheels:
1. Main Menu
2. Service
4. Calibrations
5. Lever/Pedal/Atch
When a blue number is displayed, perform the operation that corresponds with the step in table 5 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 5
Step
Operation
Engine Speed
Illustration 8 g01213420
1. Main Menu
2. Service
4. Calibrations
5. Engine Speed
When a blue number is displayed, perform the operation that corresponds with the step in table 5 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 6
Step Operation
1 Press the "OK" key (15) in order to go to the next step.
2 Press the "OK" key (15).
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 End of the calibration.
Fan Speed
Illustration 9 g01213541
1. Main Menu
2. Service
5. Fan Speed
When a blue number is displayed, perform the operation that corresponds with the step in table 7 for
the number that is displayed.
Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.
Table 7
Step
Operation
Connect the speed sensor to the fan. Then press the "OK" key (15) in order to go to the
1
next step.
Press the right key (9) or the left key (12) in order to increase or decrease the current
2 value. Tune the fan speed to the target. When you finish tuning the fan speed to the target
value, press the "OK" key (15).
3 Repeat step 2 for the new target value.
4 End of the calibration.
Copyright 1993 - 2007 Caterpillar Inc. Mon Mar 5 14:08:34 EST 2007