Systems Operation
320D, 321C, 323D, 324D, 325D, 328D, 330D, 345C, 365C, 385C, M325D and W345C
Excavators Monitoring System
Media Number -RENR8068-04 Publication Date -01/03/2006 Date Updated -29/03/2006

i02524789

Calibration Mode
SMCS - 7490

S/N - A3R1-UP

S/N - AWN1-UP

S/N - AYF1-UP

S/N - B6H1-UP

S/N - BZN1-UP

S/N - C3N1-UP

S/N - C4H1-UP

S/N - C7K1-UP

S/N - C8L1-UP

S/N - C9M1-UP

S/N - CJM1-UP

S/N - CJX1-UP

S/N - CPX1-UP

S/N - CWG1-UP

S/N - CXY1-UP

S/N - CYD1-UP

S/N - D3D1-UP
S/N - DBH1-UP

S/N - DFP1-UP

S/N - DHK1-UP

S/N - DKW1-UP

S/N - E4K1-UP

S/N - EAH1-UP

S/N - EBY1-UP

S/N - EDC1-UP

S/N - EDF1-UP

S/N - EJC1-UP

S/N - FFK1-UP

S/N - FXK1-UP

S/N - GBH1-UP

S/N - GBR1-UP

S/N - GGE1-UP

S/N - GPB1-UP

S/N - GTN1-UP

S/N - H3K1-UP

S/N - JAR1-UP

S/N - JGZ1-UP

S/N - JJG1-UP

S/N - JKR1-UP

S/N - JLP1-UP

S/N - JLS1-UP

S/N - KBA1-UP

S/N - KBE1-UP

S/N - KCR1-UP

S/N - KDG1-UP
S/N - L2K1-UP

S/N - LEM1-UP

S/N - LWR1-UP

S/N - M3M1-UP

S/N - MCH1-UP

S/N - MCL1-UP

S/N - MDC1-UP

S/N - MDE1-UP

S/N - MEY1-UP

S/N - MKR1-UP

S/N - MWP1-UP

S/N - NBD1-UP

S/N - PHX1-UP

S/N - PKE1-UP

S/N - R5K1-UP

S/N - RAS1-UP

S/N - RFN1-UP

S/N - RJK1-UP

S/N - SCR1-UP

S/N - SDC1-UP

S/N - SYM1-UP

S/N - T2S1-UP

S/N - T2Y1-UP

The "CALIBRATIONS" menu allows the user to perform calibrations


Illustration 1 g01152977
(8) Up key

(9) Right key

(10) Home key

(11) Main menu key

(12) Left key

(13) Down key

(14) Cancel key or back key

(15) OK key

The "CALIBRATIONS" menu option is entered by selecting "CALIBRATIONS" from the


"SERVICE" menu. Press the up key (8) or the down key (13) until "CALIBRATIONS" is
highlighted in order to select this option. Then press the "OK" key (15) .

Note: Refer to Systems Operation, "Service Mode" for instructions to get to the "SERVICE" menu.
Illustration 2 g01213605

The following is a list of calibrations that can be performed with the monitoring system.

Control Valves

z A1 Valve Extend

z A1 Valve Retract

z A2 Valve Extend

z A2 Valve Retract

z A3 Valve Extend

z A3 Valve Retract

Relief Valves

z Atch # 1 RLF Valve

z Atch # 2RLF Valve

PS Pres Valve

Flow Limit Valve


Lever/Pedal/Atch

z Mod L Thumbwheel

z Mod R Thumbwheel

z Left Atch Pedal

z Right Atch Pedal

Engine Speed

Fan Speed

Control Valves

Illustration 3 g01213089

Perform the following steps in order to calibrate the Control Valves:

1. Main Menu

2. Service

3. Enter the "SERVICE" password.


4. Calibrations

5. Control Valves

6. Select the desired control valve from the menu.

When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 1

Step
Operation

Connect the pressure gauge to the pressure tap corresponding to the selected valve. Then
1
press the "OK" key (15) in order to go to the next step.
2 Release all controls then press the "OK" key (15) in order to go to the next step.
Hold the thumbwheel in the forward position while pressing the "OK" key (15) in order to
3
go to the next step.
Hold the thumbwheel in the forward position while tuning the pressure to the target value.
Press the right key (9) or the left key (12) in order to increase or decrease the pressure
4
shown on the pressure gauge. When you finish tuning the pressure to the target value,
press the "OK" key (15) to go to the next step.
5 Repeat step 3.
6 Repeat step 4 for the new target value.
7 Repeat step 2.
8 End of the calibration.

Relief Valves
Illustration 4 g01213209

Perform the following steps in order to calibrate the Relief Valves:

1. Main Menu

2. Service

3. Enter the "SERVICE" password.

4. Calibrations

5. Relief Valves

6. Select the desired relief valve from the menu.

When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 2

Step
Operation

1 Connect the pressure gauge to the pressure tap corresponding to the selected valve. Then
press the "OK" key (15) in order to go to the next step.
Hold the thumbwheel in the forward position while pressing the "OK" key (15) in order to
2
go to the next step.
Hold the thumbwheel in the forward position while tuning the pressure to the target value.
Press the right key (9) or the left key (12) in order to increase or decrease the pressure
3
shown on the pressure gauge. When you finish tuning the pressure to the target value,
press the "OK" key (15) to go to the next step.
4 Repeat step 2.
5 Repeat step 3 for the new target value.
6 Release all controls then press the "OK" key (15) in order to go to the next step.
7 End of the calibration.

PS Pres Valve

Illustration 5 g01213258

Perform the following steps in order to calibrate the PS Pres Valve:

1. Main Menu

2. Service
3. Enter the "SERVICE" password.

4. Calibrations

5. PS Pres Valve

When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 3

Step
Operation

Connect the pressure gauge to the pump pressure tap. Then press the "OK" key (15) in
1
order to go to the next step.
Press the right key (9) or the left key (12) in order to increase or decrease the current
2 value. Tune the pressure to the target. When you finish adjusting then press the "OK" key
(15) to go to the next step.
3 Repeat step 2 for the new target value.
4 End of the calibration.

Flow Limit Valve


Illustration 6 g01213306

Perform the following steps in order to calibrate the Flow Limit Valve:

1. Main Menu

2. Service

3. Enter the "SERVICE" password.

4. Calibrations

5. Flow Limit Valve

6. Make the desired selection from the Flow Limit Valve screen.

When a blue number is displayed, perform the operation that corresponds with the step in table 2 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 4

Step
Operation

1 Connect the pressure gauge to the appropriate pressure tap. Then press the "OK" key (15)
in order to go to the next step.
Move stick to full in position then press the "OK" key (15) in order to go to the next step.
2

Hold stick in the full in position then press the "OK" key (15) in order to go to the next
3
step.
Hold the stick in the full in position while tuning the pressure to the target value. Press the
right key (9) or the left key (12) in order to increase or decrease the pressure shown on the
4
pressure gauge. When you finish tuning the pressure to the target value, press the "OK"
key (15) to go to the next step.
5 Repeat step 3.
6 Repeat step 4 for the new target value.
7 End of the calibration.

Lever/Pedal/Atch

Illustration 7 g01213413

Perform the following steps in order to calibrate the right and left thumbwheels:

1. Main Menu
2. Service

3. Enter the "SERVICE" password.

4. Calibrations

5. Lever/Pedal/Atch

6. Select the deisired thumbwheel from the Lever/Pedal/Atch screen.

When a blue number is displayed, perform the operation that corresponds with the step in table 5 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 5

Step
Operation

1 Press the "OK" key (15) in order to go to the next step.


2 Release all controls then press the "OK" key (15) in order to go to the next step.
Move the thumbwheel to the FORWARD position then the BACKWARD position.
3
Release the thumbwheel then press the "OK" key (15) in order to go to the next step.
4 Press the "OK" key (15) in order to go to the next step.
5 End of the calibration.

Engine Speed
Illustration 8 g01213420

Perform the following steps in order to calibrate the Engine Speed:

1. Main Menu

2. Service

3. Enter the "SERVICE" password.

4. Calibrations

5. Engine Speed

When a blue number is displayed, perform the operation that corresponds with the step in table 5 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 6

Step Operation
1 Press the "OK" key (15) in order to go to the next step.
2 Press the "OK" key (15).
3 -
4 -
5 -
6 -
7 -
8 -
9 -
10 -
11 End of the calibration.

Fan Speed

Illustration 9 g01213541

Perform the following steps in order to calibrate the Fan Speed:

1. Main Menu

2. Service

3. Enter the "SERVICE" password.


4. Calibrations

5. Fan Speed

When a blue number is displayed, perform the operation that corresponds with the step in table 7 for
the number that is displayed.

Note: It is possible for an error to occur when you are calibrating. If an error occurs during the
process of calibrating, restart the process of calibrating.

Table 7

Step
Operation

Connect the speed sensor to the fan. Then press the "OK" key (15) in order to go to the
1
next step.
Press the right key (9) or the left key (12) in order to increase or decrease the current
2 value. Tune the fan speed to the target. When you finish tuning the fan speed to the target
value, press the "OK" key (15).
3 Repeat step 2 for the new target value.
4 End of the calibration.