F.R.L.

MODULAR TYPE UAW Series Excellent Technology


Filter regulator Outstanding Products

UAW-Series UAW-Series

ONE
http://www.chanto.com.tw

ONE
Specific Product Precautions
How To Order

ONE
Installtion Maintenance

U AW 30 •3 D G 1 Warning Warning
1. EXCEPT as otherwise specified 6. INSTALL a filter/Regulator that 1. DEPRESSURIZE UNIT
Auto drain Pressure Filter by manufacturer, this product is has the same size inlet and BEFORE REMOVING GUARD
Thread type Filter regulator Body size Port size gauge element
specifically designed for outlet ports as the pipe line on AND/OR BOWL.
U RC(PT) 20 1 1/8" Differential Square 5mm compressed air service, and which in will be mounted. 2. If it is a plastic bowl unit, inspect
Nil pressure type Nil embedded 1
N NPT use with any other fluid(liquid or Avoid using fitting, couplings, daily to detect crazing, cracking,
30 2 1/4" Float type
G G D G Round 25mm gas )is a misapplication. For etc., that restrict the airflow. damage or other deterioration.
2
40 3 3/8" example, use with or injection of 7. INSTALL unit in as vertical Immediatedly replace any
40mm
50 4 1/2" 3 certain hazardous liquids or position. crazed, cracked, damaged or
6 3/4" *5m for size 20.30.40 gases in the system (such as 8. WHEN MOUNTING in a deteriorate bowl with a new
25m for size 20.30.40
alcohol or liquid petroleum combination unit with a plastic bowl and bowl guard.

Series
8 1" 40m for size 20.30.40.50
gas)could be harmful to the unit lubricator, always install unit 3. ●If unit has filter element, clean
or result in a combustible before the lubricator. periodically by removing from
condition or hazardous external 9. INSTALL with pressure filter, tapping on surface and
leakage, Before using with adjusting handle up. blowing off with air blowgun.
fluids other than air, or for non- 10. TO ADUST air pressure, turn ●If unit has soft cloth element,
Pressure Characteristics industrial applications, or for life adjustment knob/handle replace with a new one at least
support systems, consult clockwise to raise the every six months, or sooner if it
manufacturer for written regulated pressure and looks dirty or causes excessive
AW20 AW30 AW40 AW50 approval. Maximum pressure counterclockwise or lower the pressure drop 10 psig (0.7bar)
0.25 0.25 0.25 0.25
and temperature ratings for regulated pressure. or more at rated flow.
Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

Set poin t Set poin t Set poin t


Set point
plastic bowls are 150 psig (10.3 4. ●If unit is equipped with a

0.2 0.2 0.2 0.2


bar)and 125°F (52°C);and for manual petcock, drain bowl at
metal bowl 250 psig (17.2bar) least once per work shift.
and 150°F (66°C). ●If unit is equipped with a float in
0.15 0.15 0.15 0.15 2. INSTALL as close as possible the bowl, clean the bowl each
0 0 0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure MPa Inlet pressure MPa Inlet pressure MPa Inlet pressure MPa to point where air is being used. time the element is cleaned or
3. INSTALL unit with air flowing changed by turning the bowl
through the body in direction upside down and tapping onto
indicated by arrow. tabletop.Blow clean with
Flow Characteristics
4. INSTALL unit ahead of blowgun.
AW20 PT1/4"-5m AW30 PT3/8"-5m AW40 PT1/2"-5m AW50 PT1"-40m
0.6 0.6 0.6 0.6 equipment that required 5. If bowl seal is crazed, cracked or
0.5 0.5 0.5 0.5 regulated pressure. otherwise damaged or
Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

0.4 0.4 0.4 0.4 5. INSTALL unit ahead of deteriorated, replace with
0.3 0.3 0.3 0.3 equipment that requires filtered manufacturer's approved seal.
0.2 0.2 0.2 0.2 air. 6. On plastic bowl units reinstall
0.1 0.1 0.1 0.1 bowl guard before pressurizing.

0 0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000 0 2000 4000 6000 8000
Flow rate L/min (ANR ) Flow rate L/min (ANR ) Flow rate L/min (ANR ) Flow rate L/min (ANR )

1 06.03 1 06.04
F.R.L.
MODULAR TYPE UAW Series Excellent Technology
Filter regulator Outstanding Products

UAW-Series UAW-Series

ONE
http://www.chanto.com.tw

ONE
Specific Product Precautions
How To Order

ONE
Installtion Maintenance

U AW 30 •3 D G 1 Warning Warning
1. EXCEPT as otherwise specified 6. INSTALL a filter/Regulator that 1. DEPRESSURIZE UNIT
Auto drain Pressure Filter by manufacturer, this product is has the same size inlet and BEFORE REMOVING GUARD
Thread type Filter regulator Body size Port size gauge element
specifically designed for outlet ports as the pipe line on AND/OR BOWL.
U RC(PT) 20 1 1/8" Differential Square 5mm compressed air service, and which in will be mounted. 2. If it is a plastic bowl unit, inspect
Nil pressure type Nil embedded 1
N NPT use with any other fluid(liquid or Avoid using fitting, couplings, daily to detect crazing, cracking,
30 2 1/4" Float type
G G D G Round 25mm gas )is a misapplication. For etc., that restrict the airflow. damage or other deterioration.
2
40 3 3/8" example, use with or injection of 7. INSTALL unit in as vertical Immediatedly replace any
40mm
50 4 1/2" 3 certain hazardous liquids or position. crazed, cracked, damaged or
6 3/4" *5m for size 20.30.40 gases in the system (such as 8. WHEN MOUNTING in a deteriorate bowl with a new
25m for size 20.30.40
alcohol or liquid petroleum combination unit with a plastic bowl and bowl guard.

Series
8 1" 40m for size 20.30.40.50
gas)could be harmful to the unit lubricator, always install unit 3. ●If unit has filter element, clean
or result in a combustible before the lubricator. periodically by removing from
condition or hazardous external 9. INSTALL with pressure filter, tapping on surface and
leakage, Before using with adjusting handle up. blowing off with air blowgun.
fluids other than air, or for non- 10. TO ADUST air pressure, turn ●If unit has soft cloth element,
Pressure Characteristics industrial applications, or for life adjustment knob/handle replace with a new one at least
support systems, consult clockwise to raise the every six months, or sooner if it
manufacturer for written regulated pressure and looks dirty or causes excessive
AW20 AW30 AW40 AW50 approval. Maximum pressure counterclockwise or lower the pressure drop 10 psig (0.7bar)
0.25 0.25 0.25 0.25
and temperature ratings for regulated pressure. or more at rated flow.
Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

Set poin t Set poin t Set poin t


Set point
plastic bowls are 150 psig (10.3 4. ●If unit is equipped with a

0.2 0.2 0.2 0.2


bar)and 125°F (52°C);and for manual petcock, drain bowl at
metal bowl 250 psig (17.2bar) least once per work shift.
and 150°F (66°C). ●If unit is equipped with a float in
0.15 0.15 0.15 0.15 2. INSTALL as close as possible the bowl, clean the bowl each
0 0 0 0
0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1
Inlet pressure MPa Inlet pressure MPa Inlet pressure MPa Inlet pressure MPa to point where air is being used. time the element is cleaned or
3. INSTALL unit with air flowing changed by turning the bowl
through the body in direction upside down and tapping onto
indicated by arrow. tabletop.Blow clean with
Flow Characteristics
4. INSTALL unit ahead of blowgun.
AW20 PT1/4"-5m AW30 PT3/8"-5m AW40 PT1/2"-5m AW50 PT1"-40m
0.6 0.6 0.6 0.6 equipment that required 5. If bowl seal is crazed, cracked or
0.5 0.5 0.5 0.5 regulated pressure. otherwise damaged or
Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

Outlet pressure MPa

0.4 0.4 0.4 0.4 5. INSTALL unit ahead of deteriorated, replace with
0.3 0.3 0.3 0.3 equipment that requires filtered manufacturer's approved seal.
0.2 0.2 0.2 0.2 air. 6. On plastic bowl units reinstall
0.1 0.1 0.1 0.1 bowl guard before pressurizing.

0 0 0 0
0 200 400 600 800 0 500 1000 1500 0 1000 2000 3000 0 2000 4000 6000 8000
Flow rate L/min (ANR ) Flow rate L/min (ANR ) Flow rate L/min (ANR ) Flow rate L/min (ANR )