Order form MiCOM P345
Ready-to-use configuration
Vx Auxiliary Rating
24 - 32Vdc 9
48 - 110Vdc 2
110 - 250Vdc, 100 - 240Vac 3
In/Vn Rating
In = 1/5A, Vn = 100 - 120Vac 1
In = 1/5A, Vn = 380 - 480Vac 2
Hardware Options
Standard - Nothing 1
IRIG-B Only 2
2nd Rear Comms port 7
2nd Rear Comms port + IRIG-B 8
Redundant Ethernet RSTP, 2 multi-mode ST fibre ports + IRIG-B (modulated) J
Redundant Ethernet RSTP, 2 multi-mode ST fibre ports + IRIG-B (un-modulated) K
Redundant Ethernet (100Mbit/s) PRP or HSR and Dual IP, 2 LC ports + 1 RJ45 port + Modulated/Un-modulated IRIG-B Q
Redundant Ethernet (100Mbit/s) PRP or HSR and Dual IP, 3 RJ45 ports + Modulated/Un-modulated IRIG-B R
Ethernet (100Mbit/s), 1 RJ45 port + Modulated/Un-modulated IRIG-B S
Mounting Option
Flush Mounting M
Rack Mounting N
Software Issue **
Customisation
Default 8
Customer 9
05/14/2019
Order form configurator MiCOM P345
Ready-to-use configuration
1-4 5 6 7 8 9 10 11 12-13 14 15
36
Vx Aux Rating
24 - 32Vdc
48 - 110Vdc
3
110 - 250Vdc, 100 - 240Vac
In/Vn Rating
In = 1/5A, Vn = 100-120Vac 1
Hardware Options
Standard - None
IRIG-B Only
2nd Rear Comms 2
IRIG-B & 2nd Rear Comms
Redundant Ethernet RSTP, 2 multi-mode ST fibre ports + IRIG-B (modulated)
Redundant Ethernet RSTP, 2 multi-mode ST fibre ports + IRIG-B (un-modulated)
Product Specific Options
80TE Case, No Option (24 Opto Inputs + 24 Relay Outputs)
80TE Case, 24 Opto Inputs + 24 Relay Outputs + RTD
80TE Case, 24 Opto Inputs + 24 Relay Outputs + CLIO
80TE Case, 32 Opto Inputs + 24 Relay Outputs
80TE Case, 24 Opto Inputs + 32 Relay Outputs
80TE Case, 24 Opto Inputs + 24 Relay Outputs + RTD + CLIO
80TE Case, 32 Opto Inputs + 24 Relay Outputs + RTD
80TE Case, 24 Opto Inputs + 32 Relay Outputs + RTD
E
80TE Case, 32 Opto Inputs + 16 Relay Outputs + RTD + CLIO
80TE Case, 16 Opto Inputs + 32 Relay Outputs + RTD + CLIO
80TE Case, 24 Opto Inputs + 16 Relay Outputs + 4 High Break Outputs
80TE Case, 24 Opto Inputs + 16 Relay Outputs + 4 High Break Outputs + RTD
80TE Case, 24 Opto Inputs + 16 Relay Outputs + 4 High Break Outputs + CLIO
80TE Case, 24 Opto Inputs + 16 Relay Outputs + 4 High Break Outputs + RTD + CLIO
80TE Case, 16 Opto Inputs + 16 Relay Outputs + 8 High Break Outputs
Protocol/Communications Options
80TE Case, 16 Opto Inputs + 16 Relay Outputs + 8 High Break Outputs + RTD
80TE Case, 16 Opto Inputs + 16 Relay Outputs + 8 High Break
K-Bus Outputs + CLIO
80TE Case, 16 Opto Inputs + 16 Relay Outputs + 8 High Break
Modbus Outputs + RTD + CLIO 2
IEC870
DNP3.0
Mounting Option
Panel Mounting M
Rack Mounting
Language
Multilingual - English, French, German, Spanish
Multilingual - English, French, German, Russian
0
Chinese, English or French via HMI, with English or French only via Communications port
Customisation
Default 8
Customer
Accessories: ORDERED and PACKED SEPARATELY from relays
20 Hz Generator
05/14/2019
Master Text
P345312E2M0368K
Generator Protection with 100% stator earth fault via low frequency injection
Vx Aux Rating :
110 - 250Vdc, 100 - 240Vac
In / Vn Rating :
In = 1/5A, Vn = 100-120Vac
Hardware Options :
IRIG-B Only
Product Specific :
Size 16 Case, 24 Opto Inputs + 32 Relay Outputs
Protocol Options :
Modbus
Mounting :
Panel Mounting
Languages :
Multilingual - English, French, German, Spanish
Software :
36
Setting Files :
Default
ATEX II (2) G
K
K double digit in same row
5
6
7
8
9
10
11
12
13
14
15
16
17
K 18
0
0
0
0
0
0
0
0
0
0
0
0