Documente Academic
Documente Profesional
Documente Cultură
Hiley's Formula for Set Calculation of R.C. Driven Pile (For Guidance Only)
Efficiency factor, f = W + ( P x N2 )
W + P
2
= 3 + ( 1.02 x 0.45 )
3+ 1.02
= 3.207
4.02
f= 0.798
Ultimate Resistance, R = W x H x f
R
Using factor of safety, R = 2 times working load of pile
= 90 tonnes
S + C/2 = W x H x f
R
S + 26/2 = 3 x 600 x 0.798
90
S + 13 = 1435.8
90
S + 13 = 15.953
S = 15.953 - 13
S = 2.953 mm
Set / 10 Blows = 30 mm