Sunteți pe pagina 1din 3

14/5/2019 D5N XL, LGP TRACK-TYPE TRACTOR AGG00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3248 - 84) - Documentation

Previous Screen
Welcome: r464rincon
Product: TRACK-TYPE TRACTOR
Model: D5N TRACK-TYPE TRACTOR AGG01751
Configuration: D5N XL, LGP TRACK-TYPE TRACTOR AGG00001-UP
(MACHINE) POWERED BY 3126B Engine

Troubleshooting
561N, 572R Series II and 572R Pipelayers and D10R, D11R, D5M, D5N, D6M, D6N, D6R, D6R Series
II, D7R, D7R Series II and D8R Series II Track-Type Tractors Power Train Electronic Control
System
Media Number -SENR8367-20 Publication Date -01/09/2015 Date Updated -03/08/2016

i04894856

MID 113 - CID 1933 - FMI 05


SMCS - 5479-038-HR

MID 113 CID 1933 FMI 05

Conditions Which Generate This Code:

Illustration 1 g03037781
Schematic of the Left Blade Angle Solenoid

This diagnostic code is recorded when the current of the solenoid is below normal.

Note: Ensure that the diagnostic code for the solenoid is on hold and that the fault present indicator shows
"SERV CODE". This procedure can cause new diagnostic codes to be recorded. Ignore these created problems.
When the procedure is completed, clear the created problems.

Test Step 1. CHECK THE SOLENOID.


https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpa… 1/3
14/5/2019 D5N XL, LGP TRACK-TYPE TRACTOR AGG00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3248 - 84) - Documentation

A. Turn the key start switch to the ON position. Ensure that CID 1933 FMI 05 is on hold.

B. Disconnect the machine harness from the priority valve solenoid.

C. At the machine harness connector for the solenoid, place a jumper from contact 1 to contact 2.

D. Observe the status of the fault present indicator.

Expected Result:

"SERV CODE" is displayed and "SERV CODE" is NOT displayed as the jumper is installed and the jumper is
removed.

Results:

YES - The circuit is correct. The solenoid has failed. repeat this test step in order to verify that the
solenoid has failed.

Repair: Replace the solenoid.

STOP

NO - The diagnostic code remains. Proceed to test step 2.

Test Step 2. CHECK THE SIGNAL CIRCUIT FOR THE SOLENOID FOR AN OPEN.

A. Turn the key start switch to the OFF position.

B. Disconnect the J1 and J2 machine harness connectors from the ECM.

C. The jumper wire remains installed.

D. At machine harness connector J1 and J2, measure the resistance from contact 1 (F789-YL(Yellow)) to
contact 2 (K975-WH(White)).

Expected Result:

There should be less than 5.0 ohms resistance.

Results:

OK - The machine harness is correct. Proceed to test step 3.

NOT OK - There is an open circuit in the machine harness. The harness has failed.

Repair: The open is in wire F789-YL(Yellow) or in wire K975-WH(White) of the machine harness.
Repair the machine harness or replace the machine harness.

STOP

Test Step 3. DETERMINE IF THE DIAGNOSTIC CODE IS STILL ACTIVE.

A. Inspect the contacts and clean the contacts of the harness connectors.

B. Reconnect all harness connectors.

C. Turn the key start switch to the ON position.


https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpa… 2/3
14/5/2019 D5N XL, LGP TRACK-TYPE TRACTOR AGG00001-UP (MACHINE) POWERED BY 3126B Engine(SEBP3248 - 84) - Documentation

D. Enter service mode of the Caterpillar Monitoring System and clear all inactive diagnostic codes.

E. Operate the machine.

F. Stop the machine and place the parking brake switch in the OFF position.

G. Determine if the diagnostic code is present.

Expected Result:

The diagnostic code is present. "SERV CODE" is showing.

Results:

YES - The problem has not been corrected. The ECM has failed.

Repair: Exit this procedure and perform the diagnostic code procedure again. If the problem persists, the
ECM may have failed. Prior to replacing an ECM, always contact your dealership's Technical
Communicator for possible consultation with Caterpillar. This consultation may greatly reduce repair
time. See the Testing and Adjusting, "Electronic Control Module (ECM) - Replace".

STOP

NO - The diagnostic code is NOT present.

Repair: The problem does not exist at this time. The initial problem was probably caused by a poor
electrical connection or a short at one of the harness connectors that was disconnected and reconnected.
Resume normal machine operation.

STOP

Copyright 1993 - 2019 Caterpillar Inc. Tue May 14 2019 18:25:30 GMT-0500 (hora estándar de Colombia)
All Rights Reserved.
r464rincon
Private Network For SIS Licensees.

https://sisweb.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpa… 3/3

S-ar putea să vă placă și