Sunteți pe pagina 1din 16

Sitarama Lift Irrigation Scheme-Pump House Super Structure-

Design Report (Package-V)

DESIGN OF PURLINS AND SIDE GIRTS FOR


SPAN-9 m
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design
Report (Package-V)

References/
DESIGN OF PURLIN-9.0M SPAN - EAVES END
Remarks

Length of Beam = 9m

Angle of Inclination with Hori. = 10

Purlin Spacing = 1.2 m

No of Sag Rods = 2

Max B.M coefficient for = 0.1


3 Span continuous Beam

Wind Load stress increasing factor = 1

Bending Moment co-efficient = 10


(8 for Simply Support, 10 for Patially Fixed)

Deflection coeffient = 3
(5 for Simply support, 3 for Partially fixed)

Deflection Factor(span / deflection ratio= 150

Yiled stress of steel = 250 N/mm2

Dead load calculation

Roofing Material = 20 Kg/m2

Others Wt = 25 Kg/m2

Total dead Load = 45 Kg/m2

Purlin self wt Per Metre = 30.6 kg/m

Dead load per meter = 84.6 kg/m

Live Load Calculation

Live load = 150 Kg/m2

Live load per meter = 180 kg/m


Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design
Report (Package-V)

Wind load Calculation


0.06(1.08x1.15x50)2

Wind pressure = 150 Kg/m 2


Refer Doc. NO
Cl No:
Max upward Wind Pr. co-eff. = 1.5 For wind Case:

Max downward Wind Pr. co-eff. = 0

Max upward Wind load = 270 Kg/m

Max downward Wind load = 0.0 Kg/m

Assume the section as = MC 250

Area of the section- Ax = 3900 mm2

Moment of Inertia Ixx = 38800000 mm4

Moment of Inertia Iyy = 2110000 mm4

Section Modulus Zxx = 307000 mm3

Section Modulus Zyy = 38500 mm3

Plastic Section Modulus Zxx = 354647 mm3

Plastic Section Modulus Zyy = 76790 mm3

rmin = 23.26 mm

Effective Length for Bending Compress 3.000 m


Distance between sag rods 9/3 =

Overall Depth of the Section D = 250 mm

Width of Flange B = 80 mm

Thick of Flange T = 14.1 mm

Thick of Web tw = 7.2 mm

Section Classification:
B/T = 5.68 Flange Classification PLASTIC
D/T = 34.73 Web Classifcation = SEMICOMPACT

Oveall Section Classificat= SEMICOMPACT


Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design
Report (Package-V)

Load Combination's
1) 1.5*(Dead Load +Live Load)
2) 1.2*(Dead Load +Live Load + Wind Load (downward))
3) 1.5*(Dead Load +Wind Load (upward))
1) Dead load + Live Load

Total downward load = 264.6 kg/m

Load on Major axis = 260.580 kg/m

Load on Minor axis = 45.947 kg/m

Factored Major Axis Bending Mo = 31.66 kN-m


1.5*260.6x9^2/10
Factored Minor Axis Bending Mo = 0.62 kN-m

2) Dead load + Live Load + Wind load (downward)

Dead load = 84.60 kg/m

Live Load = 180 kg/m

Wind Normal to Purlin = 0 kg/m

Load on Major axis = 260.58 kg/m

Load on Minor axis = 45.95 kg/m

Factored Major Axis Bending Mo = 25.33 kN-m

Factored Minor Axis Bending Mo = 0.50 kN-m


3) Dead load + Wind load (upward)
Dead load = 84.60 kg/m

Wind Normal to Purlin = 270 kg/m

Load on Major axis = -186.69 kg/m


84.6xCOS(10)-270.0
Load on Minor axis = 14.691 kg/m
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design
Report (Package-V)

Factored Major Axis Bending Mo = 22.68 kN-m

Factored Minor Axis Bending Mo = 0.20 kN-m

Design of Sag Rod

No of Bays having Sag ro = 12

Span of the purlin = 9m

Angle inclination of Roof = 10

One Span length of = 3.000 m


3 Span contineous Beam

Mid Support Reaction Co- = 1.25

Maximum force in Sag Rod

Due to DL+LL = 264.600 * 3.000 * Sin10 * 12 *1.25


= ### Kg
1.2M
Force coeffcient for Diag = 2
From Vertical 3.000M 3.000M

Force in Diagonal Rod = 2068 * sqrt(1.2^2 + 3.000^2) / 2 *1.2

= 2783.631 Kg
Factored Load = 4175.45 Kg
Sag Rod Dia = 16 mm

Stress in Rods = 207.670 N/mm2 O.K


Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report (Package-V)

Member Section: MC 250


Status: PASS Ratio: 0.525 Critical Load Case: Critical Condition: Combined effects of yield

Design Input: Load Case DL+LL Location: 1 i.e. 9 m from start node
Section: D: 250 B: 80 tf: 14.1 tw: 7.2
Laterally Supported or Laterally Unsupported = LS ( LS = Laterally Supported, LUS = Laterally UnSupported ) Actual Length : 9
Fx: 0 Fy: 0 Fz: 0 kN Stiffners : no c/d = 1.5
Mx: 0 My: 0.62 Mz: 31.66 kN-m Maximum Effective 250 Cl: 3.8
L x: 9 L y: 3 Lz: 9 m Slenderness Ratio
K x: 1 K y: 1 Kz : 1 Yeild Stress of steel (fy) = 250 N/mm2
Cmx or CmLT: 0.9 Cmy: 0.9 Cmz: 0.9 Partial Safety Factor (gm0) = 1.1 Table 5.2
Section Properties: Unit: mm Y
A: 3900 Izz: 3.88E+07 Rzz: 99.743 14.1
Azz: 2256 Iyy: 2.11E+06 Ryy: 23.260
Ayy: 1596.96 250 Z
Zez: 307000 Zpz: 354646.632 Sz: 1.16 7.2
Zey: 38500 Zpy: 76789.991489 Sy: 1.99
weight: 30.6 kg/m 14.1
80
Slenderness Check: Unit: m
Parameters: Lzeff: 9 Lyeff: 3 Lxeff: 9
Lzeff/Rzz 90.23 O.K. Lyeff/Ryy 128.98 O.K. Cl: 3.8

Section Classification:
ε =( 250/fy)0.5 = 1.00
Flange Class: PLASTIC Web Class: SEMICOMPAC Section Class: SEMICOMPACT Table 3.1
Compression: Bending:
Minor, Y Major, Z Minor, Y Major, Z
Buckling Class c c Table 7.2 aLT = - 0.49
Imp Fac, a = 0.49 0.49 Table 7.1 fcr,b = - 90.11
KL / r = 128.98 90.23 λLT = - 1.67 Cl 8.2.2
f= 1.83 1.20 fLT = - 2.25
fcc = 121.63 248.51 Cl 7.1.2.1 cLT = - 0.27
λ = √(fy / fcc) = 1.434 1.003 fbd, N/mm2 = - 60.55
c= 0.34 0.54 Md, kN-m = 8.75 69.77 Cl 8.2
fcd, N/mm2 = 76.59 122.32
Pd, kN = 298.71 477.04 Cl 7.1.2

Shear:
Y Z kv = 5.35
Vcr , kN = 325.63 230.50 Cl 8.4.2.2 (a) Shear Buckling Design m = 0.3
Vp , kN = 325.63 230.50 Cl 8.4.1 Nominal Plastic Shear tcr,e = 821.82 l 8.4.2.2 (a)
Vd , kN = 296.02 209.55 Cl 8.4 lw = 0.42
V/Vd = 0.00 0.00 tb = 144.34
Mdv not required Mdv not required
Md without high shear force effect 8.750 69.773
Mfd = 10.255 60.476 Cl 9.2.2
b = (2V/Vd-1)2 = 1.00 1.00
Mdv, kN-m = 8.750 69.77 Mdv = Md - b(Md - Mfd) <= 1.2Zefy / gm0
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report (Package-V)

Combined Interaction:
Y Z Y Z
Nd ,kN = 886.4 886.4 Cl 9.3.1.1 n= 0.00 0.00
ny,nz = 0.00 0.00 Cl 9.3.2.1 a= 0.42 0.42 Cl 9.3.1.2
KLT = 1.000 1.000 Cl 9.3.2.1 Mnd, kN-m= 8.75 69.77
Ky,Kz = 1.00 1.00 Cl 9.3.2.2
Constants a1 a2
I Section 1.00 2 Table 9.1
α1 α2

0.525
( MM ) ( MM )
y

ndy
+
z

ndz
¿1.0
For Plastic or Compact Sections
O.K Cl 9.3.1
Section Strength :
N +M y
+
M z
≤1. 0
For Semi-Compact Sections
N M
d dy M dz

Bending and Axial Compression:


Interaction Checks Axial Minor Bending Major Bending
P +k C M +k M
Check No. 1 0.000 0.064 0.454 0.518 O.K Cl 9.3.2.2
my y z
y LT ≤1 .0
P M M
dy dy dz

Check No. 2 0.000 0.038 0.408 0.447 P +0 . 6 k C M + k C M my y mz z


O.K Cl 9.3.2.2
y z ≤1 . 0
P dz M M dy dz

Checks Ratio Load Case


Slenderness 0.516 Cl: 3.8
Tension 0.000 Cl: 6.2
Compression 0.000 Cl 7.1.2
Shear Major 0.000 Cl 8.4
Shear Minor 0.000 Cl 8.4
Bending Major 0.454 Cl 8.2
Bending Minor 0.071 Cl 8.2
Combined effects of yield 0.525 Cl 9.3.1
Combined effects of buckling (Z) 0.447 Cl 9.3.2.2
Combined effects of buckling (Y) 0.518 Cl 9.3.2.2

Check for Deflection


Vertical Deflection = 17.22 mm L /150 =60.0 OK
3x260.6x0.01x(9x1000)^4/(384x200000x38800000)
Hor. Deflection = 0.69 mm
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report (Package-V)

Member Section: MC 250


Status: PASS Ratio: 0.516 Critical Load Case: Critical Condition: Slenderness
Design Input: Load Case DL+LL+WL Location: 1 i.e. 9 m from start node
Section: D: 250 B: 80 tf: 14.1 tw: 7.2
Laterally Supported or Laterally Unsupported = LS ( LS = Laterally Supported, LUS = Laterally UnSupported ) Actual Length : 9
Fx: 0 Fy: 0 Fz: 0 kN Stiffners : no c/d = 1.5
Mx: 0 My: 0.50 Mz: 25.33 kN-m Maximum Effective 250 Cl: 3.8
L x: 9 L y: 3 Lz: 9 m Slenderness Ratio
K x: 1 K y: 1 Kz : 1 Yeild Stress of steel (fy) = 250 N/mm2
Cmx or CmLT: 0.9 Cmy: 0.9 Cmz: 0.9 Partial Safety Factor (gm0) = 1.1 Table 5.2
Section Properties: Unit: mm Y
A: 3900 Izz: 3.88E+07 Rzz: 99.743 14.1
Azz: 2256 Iyy: 2.11E+06 Ryy: 23.260
Ayy: 1596.96 250 Z
Zez: 307000 Zpz: 354646.632 Sz: 1.16 7.2
Zey: 38500 Zpy: 76789.991489 Sy: 1.99
weight: 30.6 kg/m 14.1
80
Slenderness Check: Unit: m
Parameters: Lzeff: 9 Lyeff: 3 Lxeff: 9
Lzeff/Rzz 90.23 O.K. Lyeff/Ryy 128.98 O.K. Cl: 3.8

Section Classification:
ε =( 250/fy)0.5 = 1.00
Flange Class: PLASTIC Web Class: SEMICOMPAC Section Class: SEMICOMPACT Table 3.1
Compression: Bending:
Minor, Y Major, Z Minor, Y Major, Z
Buckling Class c c Table 7.2 aLT = - 0.49
Imp Fac, a = 0.49 0.49 Table 7.1 fcr,b = - 90.11
KL / r = 128.98 90.23 λLT = - 1.67 Cl 8.2.2
f= 1.83 1.20 fLT = - 2.25
fcc = 121.63 248.51 Cl 7.1.2.1 cLT = - 0.27
λ = √(fy / fcc) = 1.434 1.003 fbd, N/mm2 = - 60.55
c= 0.34 0.54 Md, kN-m = 8.75 69.77 Cl 8.2
fcd, N/mm2 = 76.59 122.32
Pd, kN = 298.71 477.04 Cl 7.1.2

Shear:
Y Z kv = 5.35
Vcr , kN = 325.63 230.50 Cl 8.4.2.2 (a) Shear Buckling Design m = 0.3
Vp , kN = 325.63 230.50 Cl 8.4.1 Nominal Plastic Shear tcr,e = 821.82 l 8.4.2.2 (a)
Vd , kN = 296.02 209.55 Cl 8.4 lw = 0.42
V/Vd = 0.00 0.00 tb = 144.34
Mdv not required Mdv not required
Md without high shear force effect 8.750 69.773
Mfd = 10.255 60.476 Cl 9.2.2
b = (2V/Vd-1)2 = 1.00 1.00
Mdv, kN-m = 8.750 69.77 Mdv = Md - b(Md - Mfd) <= 1.2Zefy / gm0
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report (Package-V)

Combined Interaction:
Y Z Y Z
Nd ,kN = 886.4 886.4 Cl 9.3.1.1 n= 0.00 0.00
ny,nz = 0.00 0.00 Cl 9.3.2.1 a= 0.42 0.42 Cl 9.3.1.2
KLT = 1.000 1.000 Cl 9.3.2.1 Mnd, kN-m= 8.75 69.77
Ky,Kz = 1.00 1.00 Cl 9.3.2.2
Constants a1 a2
I Section 1.00 2 Table 9.1
α1 α2

0.420
( MM ) ( MM )
y

ndy
+
z

ndz
¿1.0
For Plastic or Compact Sections
O.K Cl 9.3.1
Section Strength :
N +M y
+
M z
≤1. 0
For Semi-Compact Sections
N M
d dy M dz

Bending and Axial Compression:


Interaction Checks Axial Minor Bending Major Bending
P +k C M +k M
Check No. 1 0.000 0.051 0.363 0.414 O.K Cl 9.3.2.2
my y z
y LT ≤1 .0
P M M
dy dy dz

Check No. 2 0.000 0.031 0.327 0.357 P +0 . 6 k C M + k C M my y mz z


O.K Cl 9.3.2.2
y z ≤1 . 0
P dz M M dy dz

Checks Ratio Load Case


Slenderness 0.516 Cl: 3.8
Tension 0.000 Cl: 6.2
Compression 0.000 Cl 7.1.2
Shear Major 0.000 Cl 8.4
Shear Minor 0.000 Cl 8.4
Bending Major 0.363 Cl 8.2
Bending Minor 0.057 Cl 8.2
Combined effects of yield 0.420 Cl 9.3.1
Combined effects of buckling (Z) 0.357 Cl 9.3.2.2
Combined effects of buckling (Y) 0.414 Cl 9.3.2.2

Check for Deflection


Vertical Deflection = 17.22 mm L /150 =60.0 OK
3x260.6x0.01x(9x1000)^4/(384x200000x38800000)
Hor. Deflection = 0.69 mm
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report
(Package-V)

References/
DESIGN OF SIDE WALL GIRT - 9.0M SPAN - WINDWARD SIDE
Remarks

Length of Beam = 9m

Angle of Inclination with Hori. = 90

Grit Spacing = 1.2 m

No of Sag Rods = 2 3.6

Max B.M coefficient for = 0.125


3 Span continuous Beam

Bending Moment co-efficient = 10


(8 for Simply Supported, 10 for Patially Fixed)

Deflection coeffient = 3
(5 for Simply support, 3 for Partially fixed)

Deflection Factor(span / deflection rat= 180

Max B.M coefficient for Minor Axis = 0.125


3 Span continuous Beam
Yiled stress of steel = 250 N/mm2
Dead load calculation

Cladding Material = 6 Kg/m2

Others Wt = 1 Kg/m2

Total dead Load = 7 Kg/m2

Self wt of Grit = = 30.6 kg/m

Dead load per meter = 39 kg/m

Wind load Calculation

Wind pressure = 150 Kg/m2 Refer Doc. NO


Cl No:
Max upward Wind Pr. co-eff. = 0.9 0.9 For wind Case:

Max upward Wind load = 162 Kg/m


Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report
(Package-V)

Assume the section as = MC 250

Area of the section- Ax = 3900 mm2

Moment of Inertia Ixx = 38800000 mm4

Moment of Inertia Iyy = 2E+06 mm4

Section Modulus Zxx = 307000 mm3

Section Modulus Zyy = 38500 mm3

rmin = 23.26 mm

Plastic Section Modulus Zxx = 354647 mm3

Plastic Section Modulus Zyy = 76790 mm3

Overall Depth of the Section D = 250 mm

Width of Flange B = 80 mm

Thick of Flange T = 14.1 mm

Thick of Web tw = 7.2 mm


Section Classification:
B/T = 5.68 Flange Classification = PLASTIC
D/T = 34.73 Web Classifcation = SEMICOMPACT

Oveall Section Classifica = SEMICOMPACT

1) 1.5*(Dead Load +Wind Load)

Total downward load = 39.000 kg/m

Wind load per meter = 162 kg/m

Load on Major axis = ### kg/m

Load on Minor axis = 39.000 kg/m


Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report
(Package-V)

Factored Major Axis Be = 19.683 kN-m


1.5*162.0x9^2/10
Factored Minor Axis Be = 0.658 kN-m
1.5*39x(9/3)^2x0.125
Check for Deflection
Hor. Deflection = 10.701 mm l /180 =50.00 OK
3x162.0x0.01*(9x1000)^4/(384x200000x38,800,000)
Ver Deflection = 0.975 mm

Design of Sag Rod

No of Bays having Sag r = 15

Span of the Wall Girt = 9m

Angle inclination of Roof = 90

One Span length of = 3.000 m


3 Span continuous Beam

Mid Support Reaction Co = 1.25


From Steel Designer's Manual

Maximum force in Sag Rod


Due to DL+LL = 39.000 * Sin90 * 15 * 3.000 *1.25
= ### Kg 1.2M
Factored Load = 3290.6 Kg
Vertical sag Rod dia = 16 mm
3.00 3.000M
Stress in Rods = 163.66 N/mm 2
O.K

Force coeffeient for Dia = 2


From Vertical

Force in Diagonal Rod = 2194 * sqrt(1.2^2 + 3.000^2) / 2 *1.2


= ### Kg
Factored Load = 4430.1 Kg
diagonal Rod Dia = 16 mm

Stress in Rods = ### N/mm2 O.K


Member Section: MC 250
Status: PASS Ratio: 0.516 Critical Load Case: Critical Condition: Slenderness
Design Input: Load Case DL+WL Location: 1 i.e. 9 m from start node
Section: D: 250 B: 80 tf: 14.1 tw: 7.2
Laterally Supported or Laterally Unsupported = LS ( LS = Laterally Supported, LUS = Laterally UnSupported ) Actual Length : 9
Fx: 0 Fy: 0 Fz: 0 kN Stiffners : no c/d = 1.5
Mx: 0 My: 0.20 Mz: 22.68 kN-m Maximum Effective 250 Cl: 3.8
L x: 9 L y: 3 Lz: 9 m Slenderness Ratio
K x: 1 K y: 1 Kz : 1 Yeild Stress of steel (fy) = 250 N/mm2
Cmx or CmLT: 0.9 Cmy: 0.9 Cmz: 0.9 Partial Safety Factor (gm0) = 1.1 Table 5.2
Section Properties: Unit: mm Y
A: 3900 Izz: 3.88E+07 Rzz: 99.743 14.1
Azz: 2256 Iyy: 2.11E+06 Ryy: 23.260
Ayy: 1596.96 250 Z
Zez: 307000 Zpz: 354646.632 Sz: 1.16 7.2
Zey: 38500 Zpy: 76789.991489 Sy: 1.99
weight: 30.6 kg/m 14.1
80
Slenderness Check: Unit: m
Parameters: Lzeff: 9 Lyeff: 3 Lxeff: 9
Lzeff/Rzz 90.23 O.K. Lyeff/Ryy 128.98 O.K. Cl: 3.8

Section Classification:
ε =( 250/fy)0.5 = 1.00
Flange Class: PLASTIC Web Class: SEMICOMPAC Section Class: SEMICOMPACT Table 3.1
Compression: Bending:
Minor, Y Major, Z Minor, Y Major, Z
Buckling Class c c Table 7.2 aLT = - 0.49
Imp Fac, a = 0.49 0.49 Table 7.1 fcr,b = - 90.11
KL / r = 128.98 90.23 λLT = - 1.67 Cl 8.2.2
f= 1.83 1.20 fLT = - 2.25
fcc = 121.63 248.51 Cl 7.1.2.1 cLT = - 0.27
λ = √(fy / fcc) = 1.434 1.003 fbd, N/mm2 = - 60.55
c= 0.34 0.54 Md, kN-m = 8.75 69.77 Cl 8.2
fcd, N/mm2 = 76.59 122.32
Pd, kN = 298.71 477.04 Cl 7.1.2

Shear:
Y Z kv = 5.35
Vcr , kN = 325.63 230.50 Cl 8.4.2.2 (a) Shear Buckling Design m = 0.3
Vp , kN = 325.63 230.50 Cl 8.4.1 Nominal Plastic Shear tcr,e = 821.82 l 8.4.2.2 (a)
Vd , kN = 296.02 209.55 Cl 8.4 lw = 0.42
V/Vd = 0.00 0.00 tb = 144.34
Mdv not required Mdv not required
Md without high shear force effect 8.750 69.773
Mfd = 10.255 60.476 Cl 9.2.2
b = (2V/Vd-1)2 = 1.00 1.00
Mdv, kN-m = 8.750 69.77 Mdv = Md - b(Md - Mfd) <= 1.2Zefy / gm0
Combined Interaction:
Y Z Y Z
Nd ,kN = 886.4 886.4 Cl 9.3.1.1 n= 0.00 0.00
ny,nz = 0.00 0.00 Cl 9.3.2.1 a= 0.42 0.42 Cl 9.3.1.2
KLT = 1.000 1.000 Cl 9.3.2.1 Mnd, kN-m= 8.75 69.77
Ky,Kz = 1.00 1.00 Cl 9.3.2.2
Constants a1 a2
I Section 1.00 2 Table 9.1
M M
α1 α2

0.348
( )( )
M
y

ndy
+
M
z

ndz
¿1.0
For Plastic or Compact Sections
O.K Cl 9.3.1
Section Strength :
N +M y
+
M z
≤1. 0
For Semi-Compact Sections
N M
d dy M dz

Bending and Axial Compression:


Interaction Checks Axial Minor Bending Major Bending
P +k C M +k M
Check No. 1 0.000 0.020 0.325 0.345 O.K Cl 9.3.2.2
my y z
y LT ≤1 .0
P M M
dy dy dz

Check No. 2 0.000 0.012 0.293 0.305 P +0 . 6 k C M + k C M my y mz z


O.K Cl 9.3.2.2
y z ≤1 . 0
P dz M M dy dz

Checks Ratio Load Case


Slenderness 0.516 Cl: 3.8
Tension 0.000 Cl: 6.2
Compression 0.000 Cl 7.1.2
Shear Major 0.000 Cl 8.4
Shear Minor 0.000 Cl 8.4
Bending Major 0.325 Cl 8.2
Bending Minor 0.023 Cl 8.2
Combined effects of yield 0.348 Cl 9.3.1
Combined effects of buckling (Z) 0.305 Cl 9.3.2.2
Combined effects of buckling (Y) 0.345 Cl 9.3.2.2

Check for Deflection


Vertical Deflection = 12.34 mm L /150 =60.0 OK
3x-186.7x0.01x(9x1000)^4/(384x200000x38800000)
Hor. Deflection = 0.221 mm
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report (Package-V)

Member Section: MC 250


Status: PASS Ratio: 0.516 Critical Load Case: Critical Condition: Slenderness
Design Input: Load Case DL+WL Location: 1 i.e. 9 m from start node
Section: D: 250 B: 80 tf: 14.1 tw: 7.2
Laterally Supported or Laterally Unsupported = LS ( LS = Laterally Supported, LUS = Laterally UnSupported ) Actual Length : 9
Fx: 0 Fy: 0 Fz: 0 kN Stiffners : no c/d = 1.5
Mx: 0 My: 0.66 Mz: 19.68 kN-m Maximum Effective 250 Cl: 3.8
L x: 9 L y: 3 Lz: 9 m Slenderness Ratio
K x: 1 K y: 1 Kz : 1 Yeild Stress of steel (fy) = 250 N/mm2
Cmx or CmLT: 0.9 Cmy: 0.9 Cmz: 0.9 Partial Safety Factor (gm0) = 1.1 Table 5.2
Section Properties: Unit: mm Y
A: 3900 Izz: 3.88E+07 Rzz: 99.743 14.1
Azz: 2256 Iyy: 2.11E+06 Ryy: 23.260
Ayy: 1596.96 250 Z
Zez: 307000 Zpz: 354646.632 Sz: 1.16 7.2
Zey: 38500 Zpy: 76789.991489 Sy: 1.99
weight: 30.6 kg/m 14.1
80
Slenderness Check: Unit: m
Parameters: Lzeff: 9 Lyeff: 3 Lxeff: 9
Lzeff/Rzz 90.23 O.K. Lyeff/Ryy 128.98 O.K. Cl: 3.8

Section Classification:
ε =( 250/fy)0.5 = 1.00
Flange Class: PLASTIC Web Class: SEMICOMPAC Section Class: SEMICOMPACT Table 3.1
Compression: Bending:
Minor, Y Major, Z Minor, Y Major, Z
Buckling Class c c Table 7.2 aLT = - 0.49
Imp Fac, a = 0.49 0.49 Table 7.1 fcr,b = - 90.11
KL / r = 128.98 90.23 λLT = - 1.67 Cl 8.2.2
f= 1.83 1.20 fLT = - 2.25
fcc = 121.63 248.51 Cl 7.1.2.1 cLT = - 0.27
λ = √(fy / fcc) = 1.434 1.003 fbd, N/mm2 = - 60.55
c= 0.34 0.54 Md, kN-m = 8.75 69.77 Cl 8.2
fcd, N/mm2 = 76.59 122.32
Pd, kN = 298.71 477.04 Cl 7.1.2

Shear:
Y Z kv = 5.35
Vcr , kN = 325.63 230.50 Cl 8.4.2.2 (a) Shear Buckling Design m = 0.3
Vp , kN = 325.63 230.50 Cl 8.4.1 Nominal Plastic Shear tcr,e = 821.82 l 8.4.2.2 (a)
Vd , kN = 296.02 209.55 Cl 8.4 lw = 0.42
V/Vd = 0.00 0.00 tb = 144.34
Mdv not required Mdv not required
Md without high shear force effect 8.750 69.773
Mfd = 10.255 60.476 Cl 9.2.2
b = (2V/Vd-1)2 = 1.00 1.00
Mdv, kN-m = 8.750 69.77 Mdv = Md - b(Md - Mfd) <= 1.2Zefy / gm0
Sitarama Lift Irrigation Scheme-Pump House Super Structure-Design Report (Package-V)

Combined Interaction:
Y Z Y Z
Nd ,kN = 886.4 886.4 Cl 9.3.1.1 n= 0.00 0.00
ny,nz = 0.00 0.00 Cl 9.3.2.1 a= 0.42 0.42 Cl 9.3.1.2
KLT = 1.000 1.000 Cl 9.3.2.1 Mnd, kN-m= 8.75 69.77
Ky,Kz = 1.00 1.00 Cl 9.3.2.2
Constants a1 a2
I Section 1.00 2 Table 9.1
α1 α2

0.357
( MM ) ( MM )
y

ndy
+
z

ndz
¿1.0
For Plastic or Compact Sections
O.K Cl 9.3.1
Section Strength :
N +M y
+
M z
≤1. 0
For Semi-Compact Sections
N M
d dy M dz

Bending and Axial Compression:


Interaction Checks Axial Minor Bending Major Bending
P +k C M +k M
Check No. 1 0.000 0.068 0.282 0.350 O.K Cl 9.3.2.2
my y z
y LT ≤1 .0
P M M
dy dy dz

Check No. 2 0.000 0.041 0.254 0.295 P +0 . 6 k C M + k C M my y mz z


O.K Cl 9.3.2.2
y z ≤1 . 0
P dz M M dy dz

Checks Ratio Load Case


Slenderness 0.516 Cl: 3.8
Tension 0.000 Cl: 6.2
Compression 0.000 Cl 7.1.2
Shear Major 0.000 Cl 8.4
Shear Minor 0.000 Cl 8.4
Bending Major 0.282 Cl 8.2
Bending Minor 0.075 Cl 8.2
Combined effects of yield 0.357 Cl 9.3.1
Combined effects of buckling (Z) 0.295 Cl 9.3.2.2
Combined effects of buckling (Y) 0.350 Cl 9.3.2.2

Check for Deflection


Horizontal Deflection 10.71 mm L /9 =50.0 OK
3x162.0x0.01x(9x1000)^4/(384x200000x38800000)
Vertical Deflection 0.585 mm