STAT: 200 Input files E:\Johan\00256PLCP3.

SLC and
E:\Johan\00256PLCP3.txt
STAT: 201 Output file C:\00256PLCP3.l5k
STAT: 202 Translation started lunes, abril 15, 2019 09:44:13
INFO: 18 FileType: .SLC Input Line: 1 The PROGRAM HEADER section was
processed.
Reason: The translation tool processed the PROGRAM HEADER to
determine the tool type that was used to generate the input file. Tool
types could be one of - 6200(Enhanced PLC-5), 6200(Classic PLC-5) or
APS(Slc).
INFO: 6 FileType: .SLC Input Line: 4 The RACK statement was ignored.
Reason: The translation tool does not translate RACK statements
encountered in APS processor memory files.
STAT: 299 Unknown construct IOCARD : File: E:\Johan\00256PLCP3.SLC;
skipping Input at Line: 7
STAT: 299 Unknown construct IOCARD : File: E:\Johan\00256PLCP3.SLC;
skipping Input at Line: 8
STAT: 299 Unknown construct IOCARD : File: E:\Johan\00256PLCP3.SLC;
skipping Input at Line: 9
STAT: 299 Unknown construct IOCARD : File: E:\Johan\00256PLCP3.SLC;
skipping Input at Line: 10
STAT: 299 Unknown construct IOCARD : File: E:\Johan\00256PLCP3.SLC;
skipping Input at Line: 11
STAT: 299 Unknown construct IOCARD : File: E:\Johan\00256PLCP3.SLC;
skipping Input at Line: 12
INFO: 20 FileType: .SLC Input Line: 15 The PROJECT section was
processed.

QUES: PCE001
QUES: 103 .SLC Input Line: 25 Output Line: 806 Warning: The S file
reference is not equivalent to the status file.
Reason: A status file reference was encountered. Status file
references on the RSLogix 5000 may not be the same as on the Legacy
system from which this file originated.
INFO: 23 FileType: .SLC Input Line: 25 The Source and Destination file
type of the COP instruction do not match.
Reason: The COP instruction has differing file types for source and
destination.

QUES: PCE002
QUES: 110 .SLC Input Line: 136 Output Line: 880 The address references
a timer's Accumulator (ACC) field. The translation needs to be
validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE003
QUES: 103 .SLC Input Line: 203 Output Line: 927 Warning: The S file
reference is not equivalent to the status file.
Reason: A status file reference was encountered. Status file
references on the RSLogix 5000 may not be the same as on the Legacy
system from which this file originated.
INFO: 22 FileType: .SLC Input Line: 21 The LADDER section was
processed.
QUES: PCE004
QUES: 110 .SLC Input Line: 282 Output Line: 982 The address references
a timer's Accumulator (ACC) field. The translation needs to be
validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE005
QUES: 111 .SLC Input Line: 303 Output Line: 992 The address references
a timer's Preset (PRE) field. The translation needs to be validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE006
QUES: 110 .SLC Input Line: 307 Output Line: 996 The address references
a timer's Accumulator (ACC) field. The translation needs to be
validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE007
QUES: 111 .SLC Input Line: 307 Output Line: 996 The address references
a timer's Preset (PRE) field. The translation needs to be validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE008
QUES: 103 .SLC Input Line: 321 Output Line: 1018 Warning: The S file
reference is not equivalent to the status file.
Reason: A status file reference was encountered. Status file
references on the RSLogix 5000 may not be the same as on the Legacy
system from which this file originated.
QUES: PCE009
QUES: 111 .SLC Input Line: 421 Output Line: 1097 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE010
QUES: 110 .SLC Input Line: 421 Output Line: 1097 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE011
QUES: 111 .SLC Input Line: 425 Output Line: 1102 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE012
QUES: 110 .SLC Input Line: 425 Output Line: 1102 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE013
QUES: 111 .SLC Input Line: 466 Output Line: 1128 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE014
QUES: 103 .SLC Input Line: 494 Output Line: 1152 Warning: The S file
reference is not equivalent to the status file.
Reason: A status file reference was encountered. Status file
references on the RSLogix 5000 may not be the same as on the Legacy
system from which this file originated.
QUES: PCE015
QUES: 111 .SLC Input Line: 496 Output Line: 1155 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE016
QUES: 110 .SLC Input Line: 496 Output Line: 1155 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE017
QUES: 111 .SLC Input Line: 506 Output Line: 1160 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE018
QUES: 110 .SLC Input Line: 506 Output Line: 1160 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE019
QUES: 111 .SLC Input Line: 594 Output Line: 1192 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE020
QUES: 111 .SLC Input Line: 596 Output Line: 1194 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
INFO: 22 FileType: .SLC Input Line: 205 The LADDER section was
processed.
INFO: 22 FileType: .SLC Input Line: 664 The LADDER section was
processed.
QUES: PCE021
QUES: 110 .SLC Input Line: 739 Output Line: 1334 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE022
QUES: 111 .SLC Input Line: 759 Output Line: 1345 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE023
QUES: 110 .SLC Input Line: 759 Output Line: 1345 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
QUES: PCE024
QUES: 111 .SLC Input Line: 761 Output Line: 1349 The address
references a timer's Preset (PRE) field. The translation needs to be
validated.
Reason: The address references the PRE field of a Timer. The address
has been translated but may not be correct
QUES: PCE025
QUES: 110 .SLC Input Line: 761 Output Line: 1349 The address
references a timer's Accumulator (ACC) field. The translation needs
to be validated.
Reason: The address references the ACC field of a Timer. The address
has been translated but may not be correct
INFO: 22 FileType: .SLC Input Line: 731 The LADDER section was
processed.
INFO: 21 FileType: .SLC Input Line: 832 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 835 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 838 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 842 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 846 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 849 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 852 The DATA section was
processed.
INFO: 21 FileType: .SLC Input Line: 857 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 876 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 876 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 880 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 880 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 943 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 943 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 956 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 956 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 964 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 964 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 971 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 971 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 977 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 977 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 980 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 980 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 985 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 985 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 991 The Data Table's dimension was
increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 991 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 1002 The Data Table's dimension
was increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 1002 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 1009 The Data Table's dimension
was increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 1009 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 1017 The Data Table's dimension
was increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 1017 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 1025 The Data Table's dimension
was increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 1025 The DATA section was
processed.
INFO: 26 FileType: .SLC Input Line: 1047 The Data Table's dimension
was increased to accomodate the initialization values encountered.
Reason: The data table has more data than can be accomodated; The
translation tool increased the dimension of the table so as not to
lose any of the initial values encountered.
INFO: 21 FileType: .SLC Input Line: 1047 The DATA section was
processed.
INFO: 10 FileType: .SLC Input Line: 1069 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
INFO: 10 FileType: .SLC Input Line: 1074 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
INFO: 10 FileType: .SLC Input Line: 1079 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
INFO: 10 FileType: .SLC Input Line: 1095 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
INFO: 10 FileType: .SLC Input Line: 1103 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
INFO: 10 FileType: .SLC Input Line: 1108 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
INFO: 10 FileType: .SLC Input Line: 1113 The FORCE statement was
ignored.
Reason: The translation tool does not translate FORCE tables
encountered in processor memory files.
STAT: 203 Translation completed lunes, abril 15, 2019 09:44:13