Sunteți pe pagina 1din 30

Uniformance®

Process Studio
Release 320.1
Software Change Notice
July 2014

UPSMEDX-SCN-320
Version 1.3
Copyright, Notices, and Trademarks
© Honeywell Inc. 1998 – 2014. All Rights Reserved.

US Patent #8261202.

While this information is presented in good faith and believed to be accurate, Honeywell disclaims
the implied warranties of merchantability and fitness for a particular purpose and makes no
express warranties except as may be stated in its written agreement with and for its customers.

In no event is Honeywell liable to anyone for any indirect, special or consequential damages. The
information and specifications in this document are subject to change without notice.

Honeywell, TotalPlant, Uniformance PHD, Experion, PlantScape and Business.FLEX are U.S.
registered trademarks of Honeywell Inc.

Other brand or product names are trademarks of their respective owners.

Release Information
Uniformance Process Studio
Document Revision: 1.3
Document Revision Date: July 2014
Document Number: UPSMEDX-SCN-320

Model Number: UPSMEDX-SCN-320

Honeywell Process Solutions


1860 W. Rose Garden Ln
Phoenix, Arizona 85027-2708 USA

ii  Uniformance Process Studio Release 320 Software Change Notice


Table of Contents

1. Read Me First ........................................................................................................5


1.1 Introduction ................................................................................................5
Uniformance Process Studio R320 .........................................................5
Document Purpose .................................................................................5
1.2 Important Notes .........................................................................................5
320.1 Release Notes ...............................................................................5
Installation ...............................................................................................6
Excel Companion ....................................................................................6
1.3 Customer Upgrade Guidance ....................................................................6

2. Uniformance Process Studio R320 Users, Supported Platforms and


Software .................................................................................................................7
2.1 Intended Users of this Release..................................................................7
2.2 Hardware and Operating System Requirements .......................................7
Hardware requirements...........................................................................7
Network requirements .............................................................................7
Operating system requirements ..............................................................7
Virtual Environments ...............................................................................8
2.3 Internet Explorer Compatibility ...................................................................8
2.4 Microsoft Office Compatibility ....................................................................8
2.5 Migrating to UPS320 ..................................................................................9
UPS R220 to R320 ..................................................................................9
2.6 Compatibility with other Honeywell Products .............................................9
Co-existence with Workcenter and Experion PKS ..................................9
Safeview Compatibility ..........................................................................11
GUS Compatibility .................................................................................11
PHD Server Compatibility......................................................................12
PHD Client Compatibility .......................................................................12
PHD Desktop Compatibility ...................................................................12
OPC HDA Server Compatibility .............................................................13
Tag Explorer Compatibility ....................................................................13
Uniformance Excel Companion Compatibility with Previous Versions..13
2.7 Localization, Language, and Locale Support ...........................................14
Localization ...........................................................................................14
Support for non-US English Operating System and Office Editions .....14

3. UPS Release 320 Functionality Changes .........................................................15


3.1 New Features in UPS Release 320 .........................................................15
Event Visualization ................................................................................15
Excel Companion ..................................................................................15

Uniformance Process Studio Release 320 Software Change Notice  iii


UPS Web Client .................................................................................... 15
Installation ............................................................................................. 15
Miscellaneous Usability and Aesthetic improvements .......................... 15
3.2 Functionality Removed or Not Supported ............................................... 15

4. UPS Licensing Overview ................................................................................... 16


Obtaining and Configuring UPS Licenses ............................................ 18
Commuting Licenses ............................................................................ 19
To commute a license: ......................................................................... 19
To return a commuted license: ............................................................. 19

5. Known Issues ..................................................................................................... 20


1-3GG668X........................................................................................... 20
1-29BXY5U ........................................................................................... 20
1-320IK4W ............................................................................................ 20
1-33XVCSB .......................................................................................... 20
1-POTT7S ............................................................................................ 20
1-Y3LZWV ............................................................................................ 21
1-3GBUH0J .......................................................................................... 21
1-WI9OC0............................................................................................. 21
1-Y3LZWV ............................................................................................ 21
1-Y3LZWV ............................................................................................ 22
161500 .................................................................................................. 22
1-3GJ69VI............................................................................................. 22
1-YJHELX ............................................................................................. 22
1-3FHCEOS.......................................................................................... 22
1-1FTJ3DX ........................................................................................... 23
1-3GG669X........................................................................................... 23
1-3GG7ND9 .......................................................................................... 23
1-3FSZQUT .......................................................................................... 23
1-3GG668X........................................................................................... 24
1-3FSZQUT .......................................................................................... 24
1-3G53I3J ............................................................................................. 24
1-3FXD2HX .......................................................................................... 24

6. Uniformance Process Studio Release 320 Media ........................................... 25

7. Problems Fixed in UPS R320 ............................................................................ 25

8. Enhancements implemented in UPS R320 ...................................................... 26

9. Problem Reporting ............................................................................................. 28

iv  Uniformance Process Studio Release 320 Software Change Notice


1. Read Me First

1.1 Introduction
Uniformance Process Studio R320
Uniformance Process Studio R320 includes new functionality for the product. Customers
are strongly encouraged to review the R320 Software Change Notice (this document)
prior to proceeding.

Document Purpose
ATTENTION

This document contains information a customer needs for this Uniformance Process Studio
release, including last minute changes not included in the product documentation. The
document includes information the customer must read before installing the software. The
Known Issues section may include information on known defects and related information such
as risks, workarounds, and how to avoid the issue.

Note: Updates to this document may be available from the HPS Support Online site.

https://www.honeywellprocess.com/en-US/support/Pages/search-
results.aspx?k=Uniformance%20Process%20Studio

1.2 Important Notes


320.1 Release Notes
1. This release is referred to as Uniformance Process Studio R320. It can be used for
brand new installations, or to support a migration upgrade from Uniformance Process
Studio R220, R300 or R310.
2. Please consult the HPS Support Web Site or appropriate Honeywell sources (Product
Manager) or the latest information on other Honeywell applications (such as
Business.FLEX and Experion PKS for releases that are qualified with UPS R320).
3. The latest product documents will also be posted on Honeywell Process Solutions
(HPS) On-Line Support. Customers are urged to review the documents on HPS Support
on a regular basis.
4. Customers are urged to check HPS Support on a regular basis for program updates and
patches and to review the Patch Release Letters for fixes applicable to their site.
5. UPS documentation is installed with the product in pdf and compiled help (.chm)
format. The documentation is also available in pdf format in the Documentation
directory of the installation media. Adobe Acrobat reader is not provided on the DVD
and must be installed separately.

Uniformance Process Studio Release 320 Software Change Notice  5


1. Read Me First
1.3. Customer Upgrade Guidance

Installation
 If the UPS R320 media is copied onto a network share, the UPS R320 installer will
fail to run from a UNC path, but will run from a mapped network drive.

 HMIWeb graphics builder is not installed by default (i.e. not included in the
“Typical” installation. To install HMIWeb Graphics Builder, use the “Custom”
installation option.

 Command-line installation does not support installing UPS on a network or remote


location. Also, components deployed from the command line cannot be subsequently
managed using the interactive installer (in Control Panel Programs and Features)

 The UPS installer cannot install NET 3.5 SP1 on Windows 8 or Windows Server
2012. This must be done manually by adding this feature to Windows. You may need
the Operating System installation media to do this. Refer to the Microsoft website for
more information.

Excel Companion
 The installation of legacy Excel Companion versions – from PHD Desktop or older
versions of UPS) is not recommended. The BF240 or BF241 Excel companion
provides support for LIMs and Event data and should be used instead to complement
the UPS Excel Companion.

1.3 Customer Upgrade Guidance


ATTENTION

If you have installed a pre-release copy of UPS R320, you should manually
un-install it (Control Panel > Add/Remove Programs) before installing the
release version.

6  Uniformance Process Studio Release 320 Software Change Notice


2. Uniformance Process Studio R320 Users,
Supported Platforms and Software
2.1 Intended Users of this Release
All sites are encouraged to migrate to this release in order to take advantage of the new
features as well as defect fixes provided in this release.

2.2 Hardware and Operating System Requirements


Hardware requirements
The minimum system hardware requirements are those officially published by Microsoft
for the supported operating system and .Net Framework 4.0. Refer to the Microsoft
website for details.
Recommended minimum configuration (all operating systems)
Processor: 2.4 GHz or faster 32 bit or 64 bit
Memory: 2 GB RAM (32 bit) or 4 GB RAM (64 bit)

Improved performance may be achieved on systems with better configurations.

Network requirements
100 Mbps network speed or better is recommended.
Operating system requirements
The supported operating systems for Uniformance Process Studio include the United
States English language versions of the following:

Operating system Version Service pack


Windows 8.1 x86

Windows 8 x86

Windows Server 2012 x64

Windows 2008 R2 x64 SP2

Windows 2008 SP2 x64 SP2

Windows 7 Professional x86 SP1

Windows 7 Ultimate x86 SP1

Windows 7 Professional x64 SP1

Windows 7 Enterprise x64 SP1

*Note:
Uniformance Process Studio Release 320 Software Change Notice  7
2. Uniformance Process Studio R320 Users, Supported Platforms and Software
2.3. Internet Explorer Compatibility

 Windows XP, Windows Vista, and Windows Server 2003 are not supported
Users need to ensure the minimum hardware requirements are provided as per the
Operating System Recommendations.
Refer to Section 0, Localization, Language, and Locale Support for more information
on support for non-US English Microsoft Office versions.

Virtual Environments
UPS has not been tested in a Citrix environment, although there are no known
compatibility issues.
UPS can be used in VMWare server or Workstation virtual environments.

2.3 Internet Explorer Compatibility


UPS R320 has been qualified with IE9, 10, and 11.
If HMIWeb displays need to be called up directly in IE9 or later they must be modified to
ensure that the displays work correctly in these browser versions. These modifications are
required due to changes in recent versions of Internet Explorer. A migration tool is
provided on the UPS installation media to make the necessary simple modifications to
HMIWeb display files.
Note: this procedure is not necessary for displays that will only be called up directly in
UPS (using Graphics/Web Browser dashboard element), rather than opening them in
Internet Explorer.
The bulk migration tool does the following:
1. Adds a META tag to the top of the page to ensure that it runs in the correct
document mode when opened directly in Internet Explorer
2. Replaces the opacity property of page elements. They will then display with
100% opacity.
To use the bulk migration tool:
From the UPS DVD, run:
\Utilities\HMIWeb Graphic IE Compatibility
Tool\BulkDisplayIECompatibilityUpdateTool.exe

Specify the path where the display and shape files to update are located (use the browse
button to find the location if required)
Click start to migrate displays in the nominated folder and subfolders.

2.4 Microsoft Office Compatibility


Data can be exported from UPS to Excel with the R320 Excel Companion.
The supported Microsoft Office versions for this component include the North American
English 32 bit editions of the following:

8  Uniformance Process Studio Release 320 Software Change Notice


 Office 2013 with SP1
 Office 2010 with SP2
 Office 2007 with SP3
Note: 64 bit Office versions are not supported in UPS R320
Note: Office 2013 is supported with limitations. There are known issues with respect to
office 2013. Please refer to Section 5 Known Issues for details.
Refer to Section 0, Localization, Language, and Locale Support for more information
on support for non-US English Microsoft Office versions.

2.5 Migrating to UPS320


UPS R220 to R320
Upgrading from UPS 220 to 320 may take considerable time.
In some migrations from UPS 220, the Excel Companion may not be upgraded
automatically. In this case an error message (uniformance97.xla could not be found) will
appear when Excel it is run for the first time. To resolve this, please re install Excel
Companion R320. This will uninstall the legacy version and install Excel Companion
R320.

2.6 Compatibility with other Honeywell Products


Co-existence with Workcenter and Experion PKS
Several Honeywell products including Workcenter, Uniformance Process Studio,
Experion Station, and eServer use Honeywell’s HMIWeb components and these products
may require a local installation of HMIWeb on client computers. Incompatible versions
of HMIWeb cannot be installed on the same computer.
The Uniformance Process Studio HMIWeb graphics runtime and HMIWeb Display
Builder options use HMIWeb. UPS with either of these options can only be installed with
the versions of Experion Station, eServer, and Workcenter listed in the following table.

Uniformance Process Studio Release 320 Software Change Notice  9


2. Uniformance Process Studio R320 Users, Supported Platforms and Software
2.6. Compatibility with other Honeywell Products

Product Releases with compatible


versions of HMIWeb

Experion PKS Station R400, R410, R430


Experion PKS eServer Premium client
Experion PKS eServer standard access

Workcenter (release numbers refer to Business R230 and later1


FLEX releases)
1
Workcenter 230 (and later versions) and UPS R320 can be installed on the same client
computer and will run independently. In addition, UPS R320 can call up Workcenter 230
(onwards) graphics within the UPS client as well as displaying UPS graphics. This is in
addition to the normal use of Internet Explorer to display Workcenter graphics.

TIPS

It is possible to install UPS with older versions of these products provided


that you do not install the UPS HMIWeb components (i.e. the HMIWeb
Display Builder and Graphics runtime options). In most cases the UPS
installation package will detect an existing incompatible HMIWeb version and
deselect the UPS options automatically. Alternatively, this can be done using
the Custom installation option. See the UPS Installation Guide for more
information.

UPS R320 without the graphics runtime option installed can call up
Workcenter graphics but not UPS graphics.

UPS can be used to create or edit Workcenter displays. When creating a


new Workcenter display in UPS, you may see the message “Cannot
communicate with Uniformance Process Studio or the Workcenter server”.
This is expected behavior. To avoid this message update the Workcenter
display template with the Workcenter server name. Alternatively, you can
ignore the message and update the Build time server setting in the Data
Sources property tab for the new display.

ATTENTION
UPS R320 must be installed after Workcenter if the two products are being
installed on the same computer.

To install a compatible version of Workcenter on a UPS system, you must re-


install UPS after installing Workcenter.

10  Uniformance Process Studio Release 320 Software Change Notice


Experion Compatibility
It is not recommended that UPS be installed on Experion Servers.
UPS is not intended for mission critical, on process environments. It should therefore not
be used on Console Stations, or Flex stations performing critical operator functions.

Experion Configuration Studio compatibility


When launching HMIWeb Display Builder from Configuration Studio on a system that
has UPS installed, Display Builder will be configured as the last version launched. For
example, if you have just used UPS Display Builder and then launch Display Builder
from Configuration Studio then you will see the UPS Builder rather than Experion
Display Builder. To then launch the Experion Builder, use the Start menu shortcut.

Safeview Compatibility
UPS can be installed on a supported Experion PKS Station version running Safeview.
However, UPS cannot be managed by Safeview.

ATTENTION
UPS cannot be managed by Safeview. Errors may occur in Safeview,
potentially causing Safeview to crash. Therefore Safeview should not be
used to manage UPS instances.

GUS Compatibility
UPS has been qualified with GUS R680 (TPS R421).

Uniformance Process Studio Release 320 Software Change Notice  11


2. Uniformance Process Studio R320 Users, Supported Platforms and Software
2.6. Compatibility with other Honeywell Products

PHD Server Compatibility


UPS R320 has been tested with PHD R300, PHD R310 and PHD R320 as a datasource.

PHD Server Release Minimum PHD Server Notes


patch level1

R320 Not critical for UPS Preferred PHD version for


use with UPS.

R310 Not critical for UPS Supports UPS Event


Visualization features.

R300 300.1.3

R215/R210 or earlier Not applicable Not supported


1
This column indicates the minimum patch level required or recommended.
Recommended practice to maintain PHD server at latest available patch level.

ATTENTION
Uniformance Process Studio must not be installed directly on a PHD Server
machine version 215 or earlier. The UPS installation package will attempt to
detect and prevent this situation.

Uniformance Process Studio can be installed directly on PHD Server R310


and R320 machines.

PHD Client Compatibility


UPS is deployed with PHD Client components 320.1.0.
Typically it is not necessary to update PHD Client components on a UPS machine when a
PHD Server patch is applied. This includes when the server patch includes an update to
PHD client components on the server.
UPS is tested with new PHD Server and client patches before they are released. Any
compatibility issues or special considerations will be detailed in an online update to this
document and where relevant the PHD patch release letter.

PHD Desktop Compatibility


Installation of the legacy PHD Desktop R215 package with UPS is not recommended.
Instead, a Visual PHD and Modtag package is available for UPS customers who need
these components of the PHD Desktop. See note below for details.

12  Uniformance Process Studio Release 320 Software Change Notice


ATTENTION
Visual PHD components and Modtag are not distributed with UPS. They are
available in a separate installation package which can be downloaded from
HPS Support Online. Refer to:

https://www.honeywellprocess.com/en-
US/support/_layouts/honeywell/hps/support-
product.aspx?PN=Uniformance%20Process%20Studio%20R300&column=R
eleases&k=Uniformance%20Process%20Studio

OPC HDA Server Compatibility


UPS R320 OPC data source has been qualified for use against the following OPC
Historical Data Access (HDA) servers:

Product Version

Experion PKS R410, R430

PHD R300, R310, R320

OSI PI 3.4.364.70

Note: UPS does not support connections to OPC Data Access (DA) servers.

Tag Explorer Compatibility


Uniformance Process Studio R320 now uses the UPS Tag Browser both in UPS and in
Excel Companion. This provides a common experience for deployment, usage, and
configuration across both applications.
Tag Explorer can be used with UPS R320 but users will need to manually create a
shortcut to the application to launch it. Tag Explorer is installed to:
<Installation drive>\ Program Files (x86)\Common Files\Honeywell\Uniformance
Note: Due to tightening of Windows security policies, drag and drop from Tag Explorer
to UPS Trend and/or Table may not be possible on some systems. A workaround may be
possible but will need to be considered carefully by each customer in light of potential
security concerns. Contact Support for more information.

Uniformance Excel Companion Compatibility with Previous Versions


Excel Workbooks created or saved using Uniformance Excel Companion R320 are not
backwards compatible with previous versions of Excel Companion. This is due to the
significant changes needed in Excel Companion for ease of installation, simplifying future
upgrades, and consistency of configuration and operation with UPS.
If you use any advanced function calls in VBA (such as UNIF_function_refresh) then you
will need to modify your code slightly to work with with Excel Companion R320. See the
section Migrating Advanced Functions in the Excel Companion User Guide for more
information.

Uniformance Process Studio Release 320 Software Change Notice  13


2. Uniformance Process Studio R320 Users, Supported Platforms and Software
2.7. Localization, Language, and Locale Support

2.7 Localization, Language, and Locale Support


Localization
UPS R320 supports localization. On a localized UPS system, language, date/time, and
numeric formats can automatically reflect the Locale settings of the logged-in user.
HMIWeb Display Builder also supports localization but is limited to one language per
system.
The localization procedure is documented in the Uniformance Process Studio
Localization Guide. Contact Support to request this document.

Support for non-US English Operating System and Office Editions


UPS R320 is qualified for use with US English editions of Microsoft Windows, and US
English editions of Microsoft Office.
For a list of non-US English Windows or Office editions that have been qualified by
Honeywell affiliates, refer to HPS Support Online.

14  Uniformance Process Studio Release 320 Software Change Notice


3. UPS Release 320 Functionality Changes
3.1 New Features in UPS Release 320
Event Visualization
 Events can now be retrieved directly into Excel Companion
 UPS Event search and filter capabilities have been improved
 Improved event synchronization between event trend and table

Excel Companion
 Can be deployed and configured silently
 Now shares UPS configuration. For example, data sources configured in UPS can be used
in Excel Companion
 Consistent behavior with UPS data retrieval
 Best fit support
 No dependence on Excel Addin paths – makes UPS and office upgrades easier
 Tag Explorer has been replaced with the UPS-style Tag Browser and can now share UPS
configuration and aggregate types (including BestFit)

UPS Web Client


 UPS Web Client is a minimal install of UPS R320 for users who need to call up HMIWeb
graphics directly in Internet Explorer but do not need the full capabilities of UPS. The
Web Client installation supports automated deployment by command line parameters.

Installation
 Automated deployment is now supported for all UPS components including Tag Browser
and Excel Companion

Miscellaneous Usability and Aesthetic improvements


 Numerous improvements have been made as the result of customer feedback. See Section
8 for a listing of key enhancements.

3.2 Functionality Removed or Not Supported


 PHD Releases earlier than R300 (e.g. R215) are not supported by UPS R320

Uniformance Process Studio Release 320 Software Change Notice  15


4. UPS Licensing Overview
3.2. Functionality Removed or Not Supported

4. UPS Licensing Overview


Uniformance Process Studio R320 now includes a license manager to allow licenses to be
shared between users.
A three-tier license structure is used. The license levels are Standard, Advanced, and
Developer.
The features provided in each license level are summarized in Table 1 - License Levels
and Features.

Table 1 - License Levels and Features

Component/function License level

Standard Advanced Developer

Dashboard   
Trending and Tabulating Data

Standard trend types   


 Multiple Y axis
 Single Y axis
 Strip Chart
 XY
 Histogram
 SPC
 MultiTrend (part of the new
Dashboard Functionality)
 Multi X Trend (integrated with the
UPS standard trend)
Table   
Analysis Plots   
Manual Input   
Displaying Event Data

Event Trend  
Event Table  
Accessing Data Sources

Connect to PHD datasource   


Browse PHD Tags

Connect to OPC datasource   


Browse OPC Tags   

16  Uniformance Process Studio Release 320 Software Change Notice


Component/function License level

Standard Advanced Developer

Connect to Event data source   


Exporting PHD Tag Data

Export PHD tag data to Excel Companion   


Working with Graphics and Web Pages

Open documents and web pages in UPS   


Graphic/Web Browser

View Workcenter graphics in UPS   


Graphic/Web Browser

View UPS Graphics or (migrated)   


Experion PKS graphics in UPS
Graphic/Web Browser (including on UPS
Web Client installations)

Create and Edit UPS Graphics in UPS   


HMIWeb Display Builder

Migrate Experion PKS Graphics to UPS   


Migrate Workcenter graphics to UPS   
(where required)

Process Trend Migrator   

Standard features are available in all UPS R320 installations and do not require
additional licensing.
Advanced and Developer features require a license which is obtained from a License
Server. If a license is available, the relevant features will be enabled in UPS. If no license
is available, the user will be notified and the licensed feature(s) will remain unavailable.
See the UPS Installation Guide for more information on UPS licensing.

Uniformance Process Studio Release 320 Software Change Notice  17


4. UPS Licensing Overview
3.2. Functionality Removed or Not Supported

Obtaining and Configuring UPS Licenses


The steps to configure UPS licenses are detailed in the UPS Installation Guide. A
summary is as follows:
1. Decide on how many Advanced and Developer licenses you need, based on the
expected maximum number of concurrent users of each license type
2. Order the licenses through your Honeywell Account Manager
3. The Account Manager will submit the license order to the Order Administrator
by e-mail (hpssoftwareorders@honeywell.com)
4. The Order Administrator will reply with a Software License Certificate that
includes an Order Reference (normally in the format SW-nn-nnnnn ).
5. Using the GenHostID.exe utility described in the installation guide, generate a
license.hostid file for your network License Server.
6. Important: Rename the license.hostid file generated in step 5 to include the SW
reference number from your Software License Certificate, plus the name of the
computer to be licensed. Preferred format is:
<SW Reference #>_<ComputerName>.hostID

Example: SW-12-12345_mypcname.hostid
7. Email the .hostid file generated in step 6 to the Order Administrator
(hpssoftwareorders@honeywell.com). You must quote the Order Reference
(SW- number) from the Software License Certificate in the subject line or
body of your email. If you do not have the Order Reference number you must
quote the System Name (Mnnnnn), which is also provided on the Software
License Certificate.
8. The Order Administrator will reply with a .ulmlicense file. Install the.ulmlicense
file on your License Server to activate your UPS licenses.
9. Run the ULM configuration wizard on any UPS clients which will obtain their
license from the License Server and configure the name of the License Server to
connect to. This step is not necessary if you specified the name of the license
server when you installed UPS.

TIPS
 Licenses are locked to the computer on which the .hostid file was
generated. The .hostid file contains a unique identifier for the computer
and this information is embedded in the .ulmlicense file.

 To move a license from one license server to another you will need to
generate a new .hostid file and request a new license from the Order
Administrator.

 The Network license server uses TCP port 5712. You may need to open
this port on your network to permit access to the license server.

 If you know the host name or IP address of the license server at the time

18  Uniformance Process Studio Release 320 Software Change Notice


you install UPS, you can specify it at installation time to avoid the need
to configure it after installation.

Commuting Licenses
Commuting a license reserves it exclusively for your UPS client computer for a
nominated period of time. A commuted license is unavailable to other UPS client
computers until the license has been returned or the commute period expires.
Commuting a license is useful in circumstances such as the following:

 Assigning a semi-permanent license to a high-priority user. Commuting the license


guarantees that the user will be able to obtain a license when they need it.

 Obtaining a license for “offline” use – for example to allow a user to build UPS
graphics at home when not connected to the company network/servers. However, this
scenario has limited practical value because a connection to a server is needed for
some aspects of display building, including testing.
Once you are finished with the commuted license you should return it so that it is
available to other users. When returning a license, your UPS client must be able to
communicate with the License Server over your network.

To commute a license:
1. Launch UPS and obtain the type of license that you want to commute.
2. Launch the ULM Commute Wizard from All Programs > Honeywell
3. On the Current Licenses tab, select the license you obtained in Step 1.
4. Next to the Commute Selected Licenses button , enter the number of days that you
want to commute the license for.
5. Click Commute Selected Licenses. The license has now been reserved for exclusive
use for the nominated number of days, or until you return it.

To return a commuted license:


1. Launch the ULM Commute Wizard from All Programs > Honeywell
2. Click on the Commuted Licenses tab.
3. Select the license that you want to return from the list.
4. Click Return selected licenses.

Uniformance Process Studio Release 320 Software Change Notice  19


5. Known Issues
3.2. Functionality Removed or Not Supported

5. Known Issues

1-3GG668X

Function Common Desktop Framework

Issue On Win8 & Win2012,Red-Cross is seen for Ribbon Bar & UPS flickers when there
is RDP session change.

Description Logging back into a Win8 remote session, with UPS open causes flickering

Workaround Close and reopen UPS between remote desktop sessions

1-29BXY5U
Function Excel Companion

Issue In Excel 2013, copy and pasting formula in a new sheet not supported.

Description A formula query cannot be copied and pasted into a new Excel 2013 sheet.

Workaround Copy the text of the formula rather than the cell containing the formula itself

1-320IK4W
Function Excel Companion

Issue Editing a formula in Excel 2013, does not refresh the data automatically

Description After editing a cell and pressing the ENTER key, data gets refreshed
automatically. Data gets removed from the sheet in Excel 2013

Workaround Edit query directly in standard dialog.

1-33XVCSB
Function Excel Companion

Issue Quick Chart shows floating point values as zero on German Win7 & Excel 2013.

Description Quick Chart does not currently handle culture specific floating point values in
Windows 7 and Excel 2013.

Workaround This is a MS Excel issue – continue to monitor MS future updates

1-POTT7S
Function Excel Companion

Issue Export to Excel Companion doesn't work when Polish date and number formats
are selected

20  Uniformance Process Studio Release 320 Software Change Notice


Description UPS trend export to Excel does not work when the Regional settings are Polish.

The following error is displayed:

"Old format or invalid type library. (Exception from HRESULT:0x80028018


(TYPE_E_INVDATAREAD))."

Workaround Install the Multilingual User Interface Pack for the relevant Office version.

1-Y3LZWV

Function Event Trend

Issue Event Trend ignores the Event Table filter when GroupBy option is changed.

Description The combination of changing the group by option and having filtering already on
results in event trend not filtering items from the view.

Workaround Turn off filtering

1-3GBUH0J

Function Event Trend and Event Table

Issue Inconcistency in the number of events dispayed after zoming the event trend.

Description After zooming, the number of events in the trend and table don’t match up.

Workaround None

1-WI9OC0

Function Event Trend and Event Table

Issue Events cant be seen for Event Table/Event Trend under relative time from NOW-
1M to NOW.

Description Changing the time period, pops up a “No events returned” warning.

Workaround Right click and refresh the application

1-Y3LZWV

Function Graphics

Issue Opacity in graphics does not work in IE9

Description The opacity property that is created by the display builder is not supported in IE9
and later. Graphics with this opacity levels below 99, will not appear in IE9,
regardless of the document mode the page is loaded in.

Uniformance Process Studio Release 320 Software Change Notice  21


5. Known Issues
3.2. Functionality Removed or Not Supported

Workaround Use the provided migration tool for bulk migration of existing graphics to replace
the opacity property in existing display files.

See Section 2.3 Internet Explorer for details

1-Y3LZWV

Function Graphics

Issue Shortcut Keys are not properly functioning under graphics

Description CTRL + N, CTRL + E, CTRL + D does not work in graphics

Workaround None

161500
Function Installation

Issue Uninstalling UPS, breaks the Workcenter HMI Web Display Builder Functionality.

Description After loading the display builder, a server communication error message appears
Further interaction with the display builder crashes.

Workaround Re-install Workcenter client

1-3GJ69VI
Function Installation

Issue Launching UPS 320.1, when Safeview is configured, everytime Installer


configures EPKS 430..

Description Every time UPS 320.1 is launched, Installer will prompt a message to ' Configure
EPKS 430 '.

Workaround Launch standalone UPS

1-YJHELX
Function Navigation

Issue Newly created item in navigation stays in edit mode

Description After creating a new navigation item, the keyboard focus can’t be escaped by
hitting the Enter key.

Workaround Once in this state, select any other item in the workspace, hit F2 twice (once to
enter edit mode, once to exit edit mode).

1-3FHCEOS

Function Process Trend Migration

Issue In Trend Migration,Raw Values are not getting migrated.Agreegate will be Bestfit
after migration.

22  Uniformance Process Studio Release 320 Software Change Notice


Description After migration, the value of the aggregate will be changed from RAW to BESTFIT

Workaround Update aggregates manually

1-1FTJ3DX

Function Table

Issue Cannot retrieve data for a CHAR tag

Description Attempting to retrieve data for a CHAR tag on a data table fails with “tag not
enabled for specified function.

Workaround “BestFit” aggregate is not supported for non-numeric tags. Change the aggregate
to allow for retrieval

1-3GG669X

Function Excel Companion

Issue Timestamps returned by Excel Companion are always returned as floating point
numbers, instead of dates in Excel 2010

Description This is due to an anomaly in Excel 2010. Users have reported that this issue is
fixed in Service Pack 2 for Excel 2010.

Workaround Install Service Pack 2 of Excel 2010 or manually specify timestamp format for the
column

1-3GG7ND9

Function Trend

Issue Difficult to read large numbers on statistics popup on trend

Description When displaying values with large numbers of significant figures in the hairline
legend, the value is truncated

Workaround None

1-3FSZQUT

Function Trend

Issue Cannot display integer values for enumerated tags

Description When an enumerated tag is added to the trend, display enumerated value option
is enabled by default and user cannot uncheck the option (to display the ordinal
values instead)

Workaround None

Uniformance Process Studio Release 320 Software Change Notice  23


5. Known Issues
3.2. Functionality Removed or Not Supported

1-3GG668X

Function Trend

Issue When the datasource is changed for a trend, the datasource name in the trend
legend is not updated

Description If you change the datasource for a trend – for example by dragging and dropping a
datasource from the workspace – the datasource names in the legend are not
updated.

Workaround Save and reopen the trend to display the correct datasource.

1-3FSZQUT

Function Trend

Issue User cannot fetch Integer data for Enumerated tags.

Description When you add an enumerated tag to Trend application, it enables (checks) the
enumeration by default and user can not uncheck the enumeration.

Workaround None

1-3G53I3J

Function Trend

Issue Time control and legend data entry issues when undocked.

Description User is unable to type in an undocked legend or time control.

Workaround Dock control before typing

1-3FXD2HX

Function Trend

Issue By right clicking on a chart, selecting Items Edit -> Aggregate, does not update
the legend.

Description Legend does not refresh after changing aggregate from right click menu

Workaround Save the trend application to the workspace after changing the aggregate.

Re-opening the trend from workspace will reflect the correct aggregates in the
legend.

24  Uniformance Process Studio Release 320 Software Change Notice


6. Uniformance Process Studio Release 320 Media
The following table lists the media for Uniformance Process Studio Release 320.

Label Media Product


Uniformance Process Studio DVD  Uniformance Process Studio R320
Release 320.1  Universal License Manager Server Components
51155922

Uniformance Process Studio Release 320 Software Change Notice  25


7. Problems Fixed in UPS R320
The following customer defects reported in earlier versions of UPS have been resolved in Uniformance
Process Studio R320:
Function ID Description

Framework 1-2NDVR87 UPS Crashes, if.dvw file from workspace clicked multiple times

Migration 1-2IXCPU After migration, the file location for excel companion is changed.

Navigation 1-QYT9SZ Workspaces disappear over time.

Trend 1-34N7HBL Strip Chart leaks memory when auto – refreshes

Trend 1-3AWUNVP Step” view in Legend is not persistent when a data refresh

Trend 1-38L9JE7 Modifying visibility, does not update the chart dynamically.

Trend 1-3ENQIUG PHD - UPS - fonction d'impression : fenêtre noire au lieu du

Uniformance Process Studio Release 320 Software Change Notice  25


8 Enhancements implemented in UPS R320

8. Enhancements implemented in UPS R320


The following customer-requested enhancements have been implemented as part of the
UPS R320 release.

Function ID Description
Events n/a Event selection

Events n/a Event tooltips

Events n/a Event search

Events n/a Event filtering

Events n/a Event ribbon improvements

Events 1-10BLX0K Need better method to pull Events when DB on


Untrusted Server

Excel Companion n/a Event data retrieval added

Event Table 162737 Event Table should have option to Freeze Column

Installation 176487 Support multiple license servers

Installation 161955 Provide a Web Client installation option for UPS

Installation 129001 Automated installation support for Excel Companion

Installation 1-UIKK0Q UPS Silent Install

Navigation 178809 Improvements needed for Add Existing Workspace and


Import workspace functionalities

Trend 178698 Unable to get the timestamp in UPS trends

Trend 162386 Inline chart is generally hard to view

Trend 1-JZVNJF Change font because the text is so small

Trend 162359 Tighter synchronization of legend and trend needed

Trend 1-WKNOYX Yrange not configurable on Single Y Axis chart

Trend 1-KS0IFU Y – axis change scale

Trend 1-OPNO8D Adjusting the Y range on single Y-Axis Trend

Trend 1-QO1F03 Y-Range is not available in Single Y-axis trend

Trend 1-AU6DXT Add ability to rearrange columns in trend legend

Trend 1-QMS9AL Not able to change the order of the traces

Trend 1-868VFS Trace Legend Order

Trend 1-LT3J7H UPS trends to default to tag range instead of auto-scale

Trend 1-C18IAB Customer requests bulk changes of Y ranges for all


items in a multi-trend

Trend 1-7IB2GS Impossible to change the Y-range from Auto to Tag

26  Uniformance Process Studio Release 320 Software Change Notice


Function ID Description
Trend 1-PRC66A Resetting ranges on a Trend is cumbersome

Trend 149662 Hard to quickly determine which trace corresponds to


which tag when there are numerous traces

Workspaces 174230 Workspace link icons to use associated extension icons

Uniformance Process Studio Release 320 Software Change Notice  27


9. Problem Reporting
ATTENTION
If you have questions regarding this release, please call the appropriate TAC
centre or Support organization for your region.

Honeywell
Process Solutions
1860 W Rose Garden Ln
Phoenix, AZ 85027-2708
USA