Sunteți pe pagina 1din 9

The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally

or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for
which it is specifically furnished or outside the extent of the agreed upon right of use.

REV.
DATE
28.10.2014
FR

STATUS
Pages modified under this Revision:
0814
Project N°

DOCUMENT REVISIONS
邱美媛

(name & visa)


WRITTEN BY
Unit

TYPE ESP MANUAL


B090

TECHNIP KT INDIA LIMITED


JBF PETROCHEMICALS LIMITED
MANGALORE PTA PLANT - OSBL
DCCQ

章乾龙
Document Code

(name & visa)


CHECKED BY
001
Serial N°
A
Rev.

郭潮勇

(name & visa)


APPROV./AUTHOR. BY
1/9
Page
Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 2/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

一、 概述 Overview

(1)用途:Purpose

静电除尘器是一种利用静电力作用把粉尘从烟气中分离出来的空气净化

设备。本设备主要用于火电、建材、化工、冶炼、轻工等行业的窑炉除尘除

雾、原材料及废品的回收。是保护环境、净化蓝天的理想设备。

The ESP is an air cleaning equipment which separate dust from

the flue gas by means of electrostatic force.The equipment is mainly

used for kiln and furnace dust removal, demisting, raw material and

waste recovery in thermal power, building material, chemical,

metallurgy, light industries, etc. It is the perfect equipment to

protect the environment and clean the blue sky.

(2)特点:feature

具有除尘性能优良、抗短路、可靠性好的特点。

Thanks to high dedusting capacity of the equipment, the abrasion of

induced draft fan is greatly reduced and its service life is prolonged.
which it is specifically furnished or outside the extent of the agreed upon right of use.

二、 技术特性参数

Main specification and technical parameter of equipment

产品名称: 静电除尘器

Name: Electrostatic precipitator (ESP)

型号: MT70-3

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 3/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

Type: MT70-3

(1)性能参数:technical parameter

处理烟气量:treoted flue gas volume 156000m3/h

入口烟气温度:fule gas temoerature 190℃

出口排放浓度:outlet dust concentration ≤50mg/Nm3

保证效率:de-dusting efficiency ≥99.5%

本体阻力:equipment resistance ≤300Pa

本体漏风率:casing air leakage rate <3%

(2)结构参数 Structure parameter

进口喇叭 Inlet nozzle 1 套 set

出口喇叭 Outlet nozzle 1 套 set

壳体 Casing 1 套 set

灰斗系统 Hopper 1 套 set

支座(固定支座 1 件、单向支座 4 件、双向支座 3 件)

Support (Fixed stand 1 pieces、One-way stand 4 pieces、

Two-way stand 3 pieces) 1 套 set


which it is specifically furnished or outside the extent of the agreed upon right of use.

阴极系统 Emitting system 1 套 set

阴极振打系统 DE rapping 1 套 set

阳极系统 Collecing system 1 套 set

阳极振打系统 CE rapping 1 套 set

钢支架 Steel supporting 1 套 set

楼梯走道 Stairway and platform 1 套 set

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 4/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

保温层 Insulatinglayer 1 套 set

高压进线 High votage system 3 套 set

高压电源 HV power supply(GGAj02-0.5A/72kV) 3 套 set

高压电源控制系统 HV control system 3 套 set

低压控制系统 LV control system 1 套 set

三、设备构造 Structure and feature of equipment

(1) 进口喇叭 Inlet nozzle


进 口 喇 叭是 烟道 与 工 作 室 ( 即 电 场 之 间 ) 的 过 渡 段 , 烟 气 经
过 进 口 喇 叭 要 完 成 由 原 烟 道 的小 流 通截面到工作室的大流通 截 面 的扩
散,并且达到在整个流通 截 面上气流分布的均匀 。为 实 现 上 述 功 能 ,进 口
喇叭内设有多层气流分布板。
The inlet nozzle is a transition zone between a flue duct and a chamber
(i.e. between electric fields). The flue gas passing through the inlet nozzle
accomplish its diffusion from the small flow section of the flue duct to the
large flow section of the chamber to achieve uniform gas flow distribution
over entire flow section. In order to realize the above-mentioned function,
the multiple-layer gas distribution screens are mounted in the inlet nozzle.
(2) 出口喇叭Outlet nozzle
出 口 喇 叭 是 已 经 净 化 过 的 烟 气由 工 作 室 到 烟 道 的 过 渡 段 ,
which it is specifically furnished or outside the extent of the agreed upon right of use.

为 提 高 收 尘 效 率 , 还 根 据 需 要 内 置 槽 形 板。
The outlet nozzle is a transition zone between a chamber and a flue
duct. In order to increase collection efficiency, built-in Channel plates shall be
installed in it as required.
(3) 壳体 Casing

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 5/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

壳体是电除尘器的重要组成部份,采用全部气密焊接结构,包括壳体侧

板、上下端板和内部管撑、顶板;侧板采用水平或自撑结构,顶部载荷,即主

要的载荷从顶梁通过顶板传至立柱,并沿立柱直接传至基础。

The casing is an important component of ESP, a fully airtight welded

structure and composed of casing side plate, upper and lower end plates,

internal pipe bracing and top plate.The side plate adopts a horizontal or self-

supporting structure, the top load, i.e. the main load transfers to the column

from the top beam through the top plate and directly to the foundation along

the column.

(4)灰斗 Hopper

粉尘捕集后汇集到底部锥形灰斗里,在约 30%~50%高度的部份(即斗

底)进行有效的加热以避免粉尘板结,并装有阻流板以防止气流从电场下部漏

出和膨灰。

After captured, dust is collected to the bottom pyramidal hopper.

Effective heating of section of about 30%~50% height hopper ( i.e.

hopper bottom) can prevent dust from hardening. And mount the baffle
which it is specifically furnished or outside the extent of the agreed upon right of use.

plate to prevent the gas flow and dust from leaking from the lower of

electric field.

(5)支座 Support bearing

为避免壳体热膨胀产生非规则载荷,在壳体立柱和钢支架之间配置支座,

这种支座滑动面采用摩擦系数极小的材料制成,可以沿任何水平方向滑动和旋

转而不产生较大的载荷。

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 6/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

In order to avoid the irregular load resulting from casing expansion

caused by heat, mount the support bearing between the casing column and

the steel support structure. Its sliding surface is made of material having very

small friction coefficient, and it can slide and revolve along any horizontal

direction without producing comparatively large load.

(6)阴极系统 DE system

阴极系统是电除尘器非常重要的部份,是电除尘器的心脏部件。阴极线

悬挂于框架之间,上部、中部和下部框架与吊梁牢固地连结在一起,整个框架

悬挂在 4 只绝缘套管上,绝缘套管安装在屋顶保温箱内,使烟气与外界隔离。

The DE system is a very important section and a key component of

ESP. The DE wire is hung between frames. The upper, intermediate and

lower frames are firmly joined up with the suspension beam. The entire frame

is hung from 4 insulation sleeves, which are mounted in the thermal insulation

box on roof to separate the gas flue from the environment.

(7)阴极振打 DE rapping

有效的振打来清除阴极系统上的积灰;振打是通过电磁锤完成的,振打
which it is specifically furnished or outside the extent of the agreed upon right of use.

锤安装在顶部保温箱上,根据振打制度依次撞击阴极吊梁和砧梁再传到框架以

及阴极线,采用这种方法可使锤子振打力有效地分布于全部框架和阴极线。振

打装置的运行采用 PLC 控制,对于荷电运行和防止二次飞扬, PLC 机可以编

制最佳振打方案。

effective rapping must be taken to remove the accumulated dust on the

DE system; the rapping is accomplished by electromagnetic hammers. The

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 7/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

rapping hammer is mounted on the top insulation box, according to the

rapping rule, it impacts the DE suspension beam and anvil beam in proper

order to transfer the rapping force to the frame and DE wire. By using this

way, the rapping force of hammer can be effectively distributed over all the

frames and wires. The operation of the rapping device is controlled by PLC,

and PLC can program the optimal rapping plan for charged operation and

prevention of re-entrainment.

(8)阳极系统 CE system

阳极系统是电除尘器另一个重要部件。采用一种称为 C480 型极板,这种

极板具有一种特别形状以达到圆满的电流分布和刚性,通过极板轮廓边缘设计

比传统极板进一步改进了刚度,消除了尖边角的放电火花。

The CE system is another important component. The MT type ESP

employs C480 type CE plate, which is 480mm wide, shaped by continuous

rolling and has high technological requirements. The plate has a special

shape to obtain perfect current distribution and rigidity. As compared with the

conventional CE plate, after adoption of its outline edge design the plate has
which it is specifically furnished or outside the extent of the agreed upon right of use.

the further improvement in rigidity, eliminates spark discharge at points.

(9)阳极振打 CE rapping

振打力通过振打砧梁和方钢有效地传到极板上。在电场内,颗粒较粗的

粉尘因自重原因在极板下部沉积,较细的粉尘仍在上部沉积;由于细微粉尘的

粘附力较大,因此,粉尘的清灰要求是振打力上部大下部小,而顶部振打的特

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 8/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

性就是振打力上大下小, 振打力的分布恰好符合这种清灰要求,而且是最佳

的。

In the electric field, the coarser dust particle deposits on the lower of CE

plates due to its dead weight, and the finer dust still deposits on the upper

due to its larger adhesion. Therefore, the cleaning requires large rapping

force at the upper and small rapping force at lower. The feature of top rapping

is just large rapping force at the upper and small rapping force at lower, and

the distribution of rapping force just conforms to the cleaning requirement and

is the best.

(10)钢支架 Steel support structure

钢支架由立柱、横撑和斜撑组成。

The steel support structure is composed of column, cross bracing and

diagonal bracing.

(11)高压进线、高压硅整流装置及其控制 High voltage silicon rectifying

device and its control

高压硅整流装置及其控制系统详见相关电气产品说明书。
which it is specifically furnished or outside the extent of the agreed upon right of use.

For further details of high voltage silicon rectifying device and its

control system see the manual for relative electrical products.

四、使用和维护 Use and maintenance of equipment

电除尘器设备属于大型户外综合性设备,正确的使用和维护以及有效的管

理对电除尘器的正常运行和延长其使用寿命非常重要。所以,要求每一个使用

和维护电除尘器的人员必须具有相当的文化素质,并经过专门的培训。应该建

TECHNIP KT INDIA LIMITED


Project N° Unit Document Code Serial N° Rev. Page
0814 B090 DCCQ 01 A 9/9

MANGALORE PTA PLANT - OSBL


JBF PETROCHEMICALS LIMITED
The present document or drawing is property of TECHNIP KT INDIA LIMITED and shall not, under any circumstances, be totally or partially, directly or indirectly, transferred, reproduced, copied, disclosed or used, without its prior written consent, for any purpose and in any way other than that for

立一个专门的管理机构负责电除尘器的使用和维护,建立一套严密的规章制度

有利于规范管理

The ESP belongs to large-size outdoor equipment, the correct use and

maintenance as well as effective management is very important for normal

operation and prolonged service life for ESP. Therefore, every person using

or maintaining ESP must have appropriate cultural level and be specially

trained. It is necessary to establish a special management mechanism to take

responsibility for use and maintenance of ESP and a set of meticulous rules

and regulations favorable for its normal management.