Personas M Series

5886 Drive-Up
Site Preparation and Installation

B006-6328-F000
1204
NOTICE

This is a contractual document. It contains important warning and confers important legal rights and obligations. You
are advised to read it carefully.

It is the responsibility of the customer to assure that all installation preparations are complete and in compliance with
all specifications and requirements of NCR and all applicable national, state, or local codes, regulations and laws.

The product described in this book is a licensed product of NCR Corporation.

APTRA TM and PersonasTM are trademarks of NCR Corporation

It is the policy of NCR Corporation (NCR) to improve products as new technology, components, software, and firmware
become available. NCR, therefore, reserves the right to change specifications without prior notice.

All features, functions, and operations described herein may not be marketed by NCR in all parts of the world. In some
instances, photographs are of equipment prototypes. Therefore, before using this document, consult with your NCR
representative or NCR office for information that is applicable and current.

To maintain the quality of our publications, we need your comments on the accuracy, clarity, organization, and value
of this book.

Address correspondence to:

NCR Financial Solutions Group Ltd


Information Solutions
Kingsway West
Dundee,
Scotland
DD2 3XX

© 2001, 2002, 2003, 2004


By NCR Corporation
Dayton, Ohio U.S.A.
All Rights Reserved
Federal Communications
Commission (FCC) Radio Frequency
Interference Statement

Note: This equipment has been tested and found to comply with
the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause
harmful interference in which case the user will be required to
correct the interference at his own expense.

This digital apparatus does not exceed the Class A limits for radio
Canadian Class A Device noise emissions from digital apparatus set out in the Radio
Declaration Interference Regulations of the Canadian Department of
Communications.
Le présent appareil numérique n’émet pas de bruits
radioélectriques dépassant les limites applicables aux appareils
numériques de la classe A prescrites dans le Réglement sur le
brouillage radioélectrique édicté par le ministère des
Communications du Canada.

This equipment must be installed and used in strict accordance with


Information to User the manufacturer’s instructions. However, there is no guarantee
that interference to radio communications will not occur in a
particular commercial installation. If this equipment does cause
interference, which can be determined by turning the equipment off
and on, the user is encouraged to consult an NCR service
representative immediately.

Caution NCR Corporation is not responsible for any radio or television


interference caused by unauthorised modifications of this
equipment or the substitution or attachment of connecting cables
and equipment other than those specified by NCR. Such
unauthorized modifications, substitutions, or attachments may void
the user’s authority to operate the equipment. The correction of
interference caused by such unauthorized modifications,
substitutions, or attachments will be the responsibility of the user.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation iii
iv NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Revision Record

Revision Record

Date Page Description of Change

Aug 02 All New Publication for Personas 86 Drive-Up

Sept. 03 All Update to include Cash Acceptor and Cheque


Acceptor
Title change from Personas 86 to Personas M Series
5886

Sept. 03 All Revision B: update to include short sleeve

Feb. 03 All Revision C: update to remove disclaimer relating to


Cheque Acceptor, changes to severe environment
and short sleeve height requirements

July 04 Chap 1 Revision D: update for new dispenser slides

Sept. 04 Chaps 9 Revision E: update to include new statement printer


& 10 (type 2).

Dec. 04 Chap 1 Revision F: update to ‘Installation and Service


& Chap 9 Clearance’ section and for left-hand side envelope
depository

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation v
vi NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents

Contents

Preface .....................................................................................................xiii
Site Preparation ...............................................................................xiii
Installation .......................................................................................xiv
Overview..........................................................................................xiv
Customer Responsibilities .............................................................. xv
Product Identification.....................................................................xvi

Chapter 1
Physical Requirements

Package Dimensions ............................................................................. 1-1


Manoeuvring the ATM Into Position...........................................1-2
ATM Dimensions .................................................................................. 1-4
Standard Sleeve Before Collar has Been Fitted...........................1-5
Short Sleeve Before Collar has Been Fitted ................................. 1-6
Standard Collar ...............................................................................1-7
Standard Collar With Advert Light .............................................1-8
Severe Environment Fitted ............................................................ 1-9
Cheque Acceptor Fitted ............................................................... 1-10
Heights to Main Facia Items........................................................ 1-11
Ambient Lighting.......................................................................... 1-12
Installation and Service Clearances ..................................................1-13
Recommended Clearances...........................................................1-13
Minimum Clearances ................................................................... 1-17
Exterior Wall.................................................................................. 1-26
Service Access Panels.......................................................................... 1-28
Hole in the Wall ................................................................................... 1-29
Installation Categories.................................................................. 1-29
Installing Through a Glass Wall ................................................. 1-29
Replacing 5088 With Modifications to Hole in Wall ...................... 1-30
Dimensions for an ATM With Standard Sleeve .......................1-30
Dimensions for an ATM With Short Sleeve .............................. 1-31

NCR Personas M Series 5886 Site Preparation and Installation vii


Table of Contents

Plinth Requirements .....................................................................1-31


Replacing 5688 With no Modifications to the Hole in Wall ..........1-32
Dimensions for an ATM With Standard Sleeve .......................1-32
Dimensions for an ATM With Short Sleeve ..............................1-33
Plinth Requirements .....................................................................1-33
Installing Through a New Hole.........................................................1-34
Dimensions for an ATM With Standard Sleeve .......................1-34
Dimensions for an ATM With Short Sleeve ..............................1-35
Plinth Requirements .....................................................................1-35
Sealing the Hole in the Wall Against Cold and Water...................1-36
Requirements for the Floor ................................................................1-37
Support Plinth ...............................................................................1-37
Mandatory Modifications to Plinth or Floor ...................................1-40
Concrete Plinth ..............................................................................1-40
Adjustable Plinth...........................................................................1-40
ATM Installed Directly on to the Floor......................................1-40
Floor Loading ................................................................................1-42
Security Bolts .................................................................................1-42
Floor Covering...............................................................................1-42
Infill Panel Dimensions.......................................................................1-43
Infill Panel (5088) ..........................................................................1-43
Infill Panel (5688) ..........................................................................1-44
Internal Space Constraint for Fitting a Third Party Video
Camera ...............................................................................................1-45

Chapter 2
Electrical Requirements

Power Quality Distribution and Grounding Requirements ...........2-1


AC Power Requirements ...............................................................2-1
Input Voltage Setting......................................................................2-1
Power Consumption.......................................................................2-1
Power Cable .....................................................................................2-2
Grounding Requirements ..............................................................2-2
Transient Power Loss .....................................................................2-3
EMI Susceptibility ...........................................................................2-3
EMI Emission...................................................................................2-3
Communications Requirements ..........................................................2-4
High Order Communications Cable ............................................2-4
Remote Device Cables ....................................................................2-6

viii NCR Personas M Series 5886 Site Preparation and Installation


Table of Contents

Chapter 3
Environmental Requirements

Environmental Requirements.............................................................. 3-1


Temperature and Humidity .......................................................... 3-1
Barometric Pressure........................................................................3-2
Electromagnetic Compatibility (EMC) and Safety..................... 3-4
Acoustics ..........................................................................................3-4
Heat Dissipation.............................................................................. 3-4
Air Flow............................................................................................ 3-4
Temperature Rise ............................................................................ 3-4

Chapter 4
Decal Requirements

Decal Dimensions .................................................................................. 4-1


Card Orientation Window.............................................................4-2
Card Acceptance Decal .................................................................. 4-3
Clear Window .................................................................................4-3
Advert Light .................................................................................... 4-4
Entry/Exit Slot Decals.................................................................... 4-5

Chapter 5
Installation Accessories and Planning Check List

Installation Accessories ........................................................................5-1


Planning Check List .............................................................................. 5-2

Chapter 6
Installation Procedure

Introduction............................................................................................ 6-1
Installation Steps ............................................................................. 6-1
Site Preparation ...............................................................................6-1
Tools Required For ATM Installation .......................................... 6-1
Moving the ATM............................................................................. 6-2

NCR Personas M Series 5886 Site Preparation and Installation ix


Table of Contents

Chapter 7
Preparing the ATM For Installation

Removing the External Packaging From the ATM...........................7-1


Inspecting the ATM For Damage .................................................7-1
Installation Report Form ................................................................7-2
Opening the ATM..................................................................................7-3
How to Open the ATM ..................................................................7-3
How to Unlock and Lock the Standard Security Enclosure............7-5
Keylocks ...........................................................................................7-6
Combination Locks .........................................................................7-6
Combination Lock and Separate Keylock ...................................7-8
How to Unlock and Lock an Electronic Lock ..................................7-12
Unlocking .......................................................................................7-12
Locking ...........................................................................................7-13
Emergency Opening Procedure..................................................7-14
How to Unlock and Lock a Controlled Access Electronic Lock ...7-15
Controlled Access Electronic Lock (Type 1) .............................7-16
Controlled Access Electronic Lock (Type 2) .............................7-18
Removing the ATM From Its Pallet ..................................................7-24

Chapter 8
Installing the ATM – Physical Installation

Introduction............................................................................................8-1
Installation Categories....................................................................8-1
Connecting Cables ..........................................................................8-1
Fitting the Severe Environment Parts.................................................8-2
Dismantling the Severe Environment Parts ................................8-2
Removing the 80-Column Printer.................................................8-4
Removing the Side-Access Service Panel ....................................8-7
Fitting the Severe Environment Parts ........................................8-11
Sealing the ATM............................................................................8-17
Fitting a Cheque Acceptor Bin (If Configured)...............................8-22
Cheque Acceptor Bin With a Keylock........................................8-22
Cheque Acceptor Bin With a Sub-Lock .....................................8-24
Positioning the ATM ...........................................................................8-27
Fitting An Infill Panel..........................................................................8-28
Infill Panel (5088) ..........................................................................8-28
Infill Panel (5688) ..........................................................................8-29
Fitting the Collar ..................................................................................8-31

x NCR Personas M Series 5886 Site Preparation and Installation


Table of Contents

Fitting the Standard Collar With Facia Light............................ 8-31


Fitting the Standard Collar With Advert Light ........................ 8-36
Sealing the Collar and Bolting the ATM to the Plinth ................... 8-44

Chapter 9
Installing the ATM – Internal Packaging and Cables

Removing the Internal Packaging....................................................... 9-1


Module Locations .......................................................................... 9-2
Top-Box ............................................................................................ 9-3
Security Enclosure .......................................................................... 9-4
Operator Panel ................................................................................ 9-5
Currency Dispenser ........................................................................9-6
PC Core............................................................................................. 9-8
Magnetic Card Reader/Writer......................................................9-9
Receipt and Journal Printers ....................................................... 9-10
80 Column Printer Release Latch................................................ 9-11
Statement Printer .......................................................................... 9-12
Depository and Depository Bin ..................................................9-14
Cash Acceptor ...............................................................................9-16
Cheque Acceptor........................................................................... 9-17
Connecting Cables to the ATM ......................................................... 9-18
Power Cable................................................................................... 9-18
Connecting All Other Cables ...................................................... 9-21

Chapter 10
Configuring the ATM

Introduction.......................................................................................... 10-1
Currency Cassette Configuration...................................................... 10-2
Device Configuration.......................................................................... 10-3
Communications Configuration ....................................................... 10-4
Self-Service Support ..................................................................... 10-4
S4I .................................................................................................... 10-4
Currency Dispenser Configuration ..................................................10-5
Strapping ........................................................................................10-5
Currency Cassette Configuration...................................................... 10-6
40-Column Printer Configuration..................................................... 10-7
Thermal Receipt and Journal Printers........................................ 10-7
Basic Configuration ......................................................................10-8
Advanced Configuration and Calibration ................................10-8
Dot-Matrix Journal Printer ........................................................ 10-12

NCR Personas M Series 5886 Site Preparation and Installation xi


Table of Contents

80-Column Printer Configuration ...................................................10-13


Adjusting DIP Switch Settings ..................................................10-14
Adjusting Jumper JP1 (Type 2 Printer only) ...........................10-16
Adjusting Hopper Paper Guides ..............................................10-16
Adjusting the Contrast ...............................................................10-22
Capture Bin Threshold ...............................................................10-23
Envelope Dispenser...........................................................................10-24
Adjusting the Spacer Length .....................................................10-28

Chapter 11
Fitting Decals to the ATM

Fitting the Decals .................................................................................11-1


Advert Light ..................................................................................11-1
Card Orientation Window and Clear Window ........................11-1
Entry/Exit Decals..........................................................................11-2
Card Acceptance Decal ................................................................11-2

Appendix A
Transient and Power Protection

AC Power Line Transient Protection .................................................A-1


Data Line Transient Protection ...........................................................A-3
NCR Power Protection and Cabling Products .................................A-4
AC Power Line Transient Protection ..........................................A-4
Data Line Transient Protection ....................................................A-5
Uninterruptible Power Supplies ..................................................A-5
Contact Information ......................................................................A-7

Index
Index................................................................................................Index-1

User Feedback Form

xii NCR Personas M Series 5886 Site Preparation and Installation


Preface

Preface

Chapter 1 to Chapter 5 of this document contain the information


Site Preparation necessary for the preparation of a site conforming to NCR
specifications. It is very important that the site complies with the
requirements specified these chapters because, once the equipment
has been installed, deficiencies in site preparation or the problems
caused by these deficiencies are much more difficult to detect and
correct. Further, failure to comply with these requirements or to
take proper steps to protect equipment against risks identified in
this document may cause serious damage to the equipment and to
the customer’s business.
In addition to the need to comply with the requirements specified,
electrical wiring and mechanical systems must also comply with all
relevant codes, laws and regulations.
It is important that the site be prepared by a customer or his agent
who is fully conversant with the special requirements of electronic
equipment. The responsibility for ensuring that the site is prepared
in compliance with this document remains with the customer.
For information and guidance only, a list is provided, in general
terms, of those matters for which the customer is responsible. This
list is not intended to be comprehensive, and in no way modifies,
alters, or limits the responsibility of the customer for all aspects of
adequate site preparation.
NCR staff will be available to answer questions relating to the
contents of the chapters but, except where:
a the customer has been notified that a full or partial consultancy
service is available and/or that NCR will be willing to
undertake a preliminary or final site survey and
b the customer shall have entered into a formal contract with NCR
for provision of the same.
No comment, suggestion or advice offered or not offered about
preparation of the site nor any inspection of the site whether before
or after preparation is to be taken as approval of the location of the
site and equipment or of its preparation and NCR will not be liable
in respect of any comment, suggestion or advice given by its staff or
in respect of any failure to give advice.
Finally, only the customer can know the full extent of damage
which may be caused to his business by reason of failure of the
equipment which is to be installed. For this reason it is the
customer’s responsibility to ascertain the extent of any such possible
damage to his existing or planned business, and to effect full
insurance in respect of it.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation xiii
Preface

Chapter 6 to Chapter 11 are intended for NCR personnel or NCR


Installation customer personnel who are required to install an NCR 5886 Drive-
Up Automated Teller Machine (ATM).
The chapters describe how to move the ATM from its point of
delivery and install it in the required location.
The procedures are presented in six chapters with the following
contents:
● Chapter 6 lists the steps and tools required to install an ATM,
and details how to move the ATM to the installation site
● Chapter 7 describes how to unpack the ATM and remove it from
its pallet
● Chapter 8 describes the installation of the ATM through the hole
in the wall
● Chapter 9 describes how to remove the internal packaging and
how to connect cables
● Chapter 10 describes the configuration procedure
● Chapter 11 describes how to fit decals to the front of the ATM.
The procedures, from Chapter 6 to Chapter 10, must be followed in
sequence. The procedures in Chapter 11 can be carried out at any
time, before or after the installation of the ATM.

The NCR Personas M Series 5886 Drive-Up Automated Teller


Overview Machine (ATM) is a self-service ATM which may be installed
through any suitable exterior wall or kiosk, in the first drive-up
lane.
This publication is specific to Drive-Up. For the Walk-Up version,
refer to the publication ‘Personas M Series 5886 Site Prep Manual’
(B006-6191) or ‘Personas M Series 5886 Installation Manual’
(B006-6193).
The 5886 is available as:
● Walk-Up
● short sleeve (UL security enclosure only)
● standard sleeve.
● Drive-Up (UL security enclosure only)
● short sleeve
● standard sleeve.
The ATM is designed to provide a range of services such as:
● Cash withdrawals
● Statement printing
● Cheque book requests

xiv NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preface

● Account enquiries
● Transfers
● Envelope deposits
● Envelope dispensing
● Cheque Deposits
● Cash Deposits.

The customer must do or provide the following:


Customer Responsibilities
● When required by NCR, provide the NCR customer service
representative with appropriate drawings that indicate:
● Location of the equipment
● Site wiring (power and signal, paths and lengths)
● Location of other equipment capable of generating electrical
noise, electromagnetic interference, heat, etc.
● Make building alterations necessary to meet wiring and other
site requirements.
● Provide and install all communications cables, wall jacks,
special connectors, and associated hardware.
● Provide and install necessary power distribution boxes,
conduits, grounds, lightning protection, and associated
hardware.
● Make sure all applicable codes, regulations and laws (including,
but not limited to, electrical, building, safety, and health) are
met.
● Provide and install auxiliary power or other equipment as
required.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation xv


Preface

● Provide storage or service areas as required.


● Make sure the environmental requirements of the system/unit
are met.
● Provide floor coverings and environmental systems that limit or
control static electricity build-up and discharge.
● Install the product at a height which meets the accessibility
regulations of the relevant country.

The product is identified by a class type number, 5886, and a 4 digit


Product Identification model number which is printed on a label fixed inside the top
cabinet of the ATM and above the receipt printer. The first two
digits of the model number identify the major model (normally 01),
the next two digits identify the minor model (normally 01). The
serial number is unique to each ATM. The tracer number is used to
identify where the ATM was built. Please quote all of the serial and
tracer numbers, including the prefix, when making reference to the
ATM.

Model: XXXX
Class: 5886 Tracer: XX-XXXXX
NCR Global Soltutions Ltd.
Serial: XX-XXXXXXXX

Made in UK
Vac: 220 - 240 Hz: 50/60 A:6.3

U L
LISTED
649  LR 32207
Automated Teller Machine
24 Hour Service Level 1

Electromagnetic Compatibility
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

This apparatus does not exceed Class A limits for radio noise emissions set out in the Radio Interference
Regulations of Canada.

Le present appariel n’emet pas de bruits radioelectriques depassant les limites de la classe A prescrites
dans le Reglement sur le brouillage radioelectrique du Canada.

‘’Complies with FDA Radiation Performance Standards, 21 CFR Subchapter J’‘

xvi NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Physical Requirements

Chapter 1
Physical Requirements

Package Dimensions 1-1


Manoeuvring the ATM Into Position 1-2

ATM Dimensions 1-4


Standard Sleeve Before Collar has Been Fitted 1-5
Short Sleeve Before Collar has Been Fitted 1-6
Standard Collar 1-7
Standard Collar With Advert Light 1-8
Severe Environment Fitted 1-9
Cheque Acceptor Fitted 1-10
Heights to Main Facia Items 1-11
Topmost Viewable Facia Item 1-12
Ambient Lighting 1-12

Installation and Service Clearances 1-13


Recommended Clearances 1-13
Important Notice to Users 1-13
Standard Sleeve Recommended Clearances 1-14
Short Sleeve Recommended Clearances 1-15
Minimum Clearances 1-17
Important Notice to Users 1-17
Standard Sleeve Minimum Clearances (Envelope
Depository Module and/or Currency Dispenser) 1-18
Short Sleeve Minimum Clearances (Envelope
Depository Module and/or Currency Dispenser) 1-20
Standard Sleeve Minimum Clearance (Cheque Acceptor
(Type 2) and/or Cash Acceptor (UD-686), or Dual
Dispenser) 1-22
Exterior Wall 1-26
Standard Collar 1-26
Standard Collar With Advert Light 1-27

Service Access Panels 1-28

Hole in the Wall 1-29

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents
Physical Requirements

Installation Categories 1-29


Installing Through a Glass Wall 1-29

Replacing 5088 With Modifications to Hole in Wall 1-30


Dimensions for an ATM With Standard Sleeve 1-30
Dimensions for an ATM With Short Sleeve 1-31
Plinth Requirements 1-31

Replacing 5688 With no Modifications to the Hole in Wall 1-32


Dimensions for an ATM With Standard Sleeve 1-32
Dimensions for an ATM With Short Sleeve 1-33
Plinth Requirements 1-33

Installing Through a New Hole 1-34


Dimensions for an ATM With Standard Sleeve 1-34
Dimensions for an ATM With Short Sleeve 1-35
Plinth Requirements 1-35

Sealing the Hole in the Wall Against Cold and Water 1-36

Requirements for the Floor 1-37


Support Plinth 1-37
Standard Sleeve Installation 1-38
Short Sleeve Installation 1-39

Mandatory Modifications to Plinth or Floor 1-40


Concrete Plinth 1-40
Adjustable Plinth 1-40
ATM Installed Directly on to the Floor 1-40
Floor Loading 1-42
Security Bolts 1-42
Floor Covering 1-42

Infill Panel Dimensions 1-43


Infill Panel (5088) 1-43
Infill Panel (5688) 1-44

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents
Physical Requirements

Internal Space Constraint for Fitting a Third Party


Video Camera 1-45

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents
Physical Requirements

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
1

Package Dimensions

Package Dimensions 1

The dimensions of a packaged ATM are shown below.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-1
Physical Requirements
Package Dimensions

Ensure that doorways and corridors leading to your point of


Manoeuvring the ATM installation are wide enough to allow the package to pass through,
Into Position 1
or make arrangements to unpack the ATM in an area with sufficient
access and then move it to the installation site. Also ensure that any
corridors can support the weight of the ATM.
The following table shows the minimum dimensions for doorways,
corridors with right angle corners and the space required to rotate
an ATM on its axis.

Note 1: The dimensions assume the ATM is being moved using


equipment that does not extend beyond the base of the ATM or
packaging.

Note 2: A surrounding clearance of 6 mm (0.25 in.) has been


allowed in the figures.

1-2 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Package Dimensions

Unpackaged ATM Unpackaged ATM


Packaged ATM
(Standard Sleeve) (Short Sleeve)

A Doorway or 827 mm 827 mm 1007 mm


straight corridor (32.56 in.) (32.56 in.) (39.65 in.)
B Corridor with 1009 mm 969 mm 1221 mm
corner (39.72 in.) (38.15 in.) (48.07 in.)
C Rotation about 1455 mm 1363 mm 1754 mm
centre (57.28 in.) (53.66 in.) (69.06 in.)

A B

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-3
Physical Requirements
ATM Dimensions

ATM Dimensions 1

The following illustrations show dimensions for ATM’s configured


with UL security enclosures.

Note: Cables enter the ATM through the hole in the base of the
ATM security enclosure. The location of the hole is shown in the
illustration “Support Plinth” (see page 1-29).

1-4 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
ATM Dimensions

The dimensions in the illustration below show the ATM before a


Standard Sleeve Before collar has been fitted.
Collar has Been Fitted 1

55.0 mm
(2.17 in.)

600.0 mm
(23.62 in.)

160.0 mm 804.7 mm
(6.30 in.) (31.68 in.)

1185.7 mm
(46.68 in.)

4.8 mm
1257.0 mm (0.19 in.)
(49.49 in.) 1105.0 mm
(43.50 in.)

511.0 mm 515.6 mm
(20.12 in.) (20.30 in.)

815.0 mm 350.7 mm 835.0 mm


(32.09 in.) (13.81 in.) (32.87 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-5
Physical Requirements
ATM Dimensions

The dimensions in the illustration below show the ATM before a


Short Sleeve Before Collar collar has been fitted.
has Been Fitted 1

55.0 mm
(2.17 in.)

600.0 mm
(23.62 in.)

160.0 mm 804.7 mm
(6.30 in.) (31.68 in.)

1072.4 mm
(42.22 in.)

4.8 mm
1257.0 mm (0.19 in.)
(49.49 in.) 1105.0 mm
(43.50 in.)

511.0 mm 515.6 mm
(20.12 in.) (20.30 in.)

815.0 mm 237.4 mm 835.0 mm


(32.09 in.) (9.35 in.) (32.87 in.)

1-6 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
ATM Dimensions

The dimensions in the illustration below show a standard sleeve


Standard Collar 1

ATM with a standard collar fitted.

55.0 mm
(2.17 in.)

600.0 mm
(23.62 in.)

160.0 mm 804.7 mm
(6.30 in.) (31.68 in.)

322.7 mm
715.0 mm 37.5 mm (12.70 in.)
(28.15 in.) (1.48 in.) See Note

1257.0 mm
1175.3 mm
(49.49 in.)
(46.27 in.)

464.9 mm 511.0 mm
(18.30 in.) (20.12 in.)

815.0 mm 835.0 mm
(32.09 in.) (32.87 in.)

Note: For short sleeve terminals, this dimension is


209.4 mm (8.24 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-7
Physical Requirements
ATM Dimensions

The dimensions in the illustration below show a standard sleeve


Standard Collar With ATM with a standard collar with advert light fitted.
Advert Light 1

55.0 mm
(2.17 in.)

600.0 mm
(23.62 in.)

160.0 mm 804.7 mm
(6.30 in.) (31.68 in.)

715.0 mm
(28.15 in.) 37.5 mm 322.7 mm
(1.48 in.) (12.70 in.)
See Note

1338.3 mm 1257.0 mm
(52.69 in.) (49.49 in.)

464.9 mm 511.0 mm
(18.30 in.) (20.12 in.)

815.0 mm 835.0 mm
(32.09 in.) (32.87 in.)

Note: For short sleeve terminals, this dimension is


209.4 mm (8.24 in.)

1-8 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
ATM Dimensions

The dimensions in the illustration below show the ATM with severe
Severe Environment Fitted 1

environment fitted.

248.0 mm 188.1 mm 82.2 mm


(9.76 in.) (7.41 in.) (3.24 in.)

224.0 mm
(8.82 in.)

452.0 mm
(17.80 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-9
Physical Requirements
ATM Dimensions

The dimensions in the illustration below show the ATM with a


Cheque Acceptor Fitted 1

cheque bin when a cheque acceptor has been fitted.

134.0 mm
(5.28 in.)
Without Bin
285.5 mm 16.5 mm
(11.24 in.) (0.65 in.)

144.0 mm
(5.67 in.)

230.5 mm 15.0 mm
(9.07 in.) (0.59 in.)

92.5 mm
(3.64 in.)

224.3 mm
(8.83 in.)

540.6 mm
(21.28 in.)

1-10 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
ATM Dimensions

The following table gives the heights and depths to the main facia
Heights to Main Facia items, located on the 5886 Drive-Up facia. All the height dimensions
Items 1
are calculated from road level and are based on the ATM being
installed at the optimum height, given in the “Hole In The Wall”
section later in this chapter.

Height Depth
Item
(from Road Level) (from front of Collar)
A Statement 1317.7 mm (51.88 in.) 151.0 mm (5.94 in.)
B Display 1171.7 mm (46.13 in.) 150.5 mm (5.93 in.)
C 2nd Functional Display Key 1123.0 mm (44.21 in.) 120.0 mm (4.72 in.)
D 1st Functional Display Key 1090 mm (42.91 in.) 115.0 mm (4.53 in.)
E Cash Exits 1 & 2 1023.6 mm (40.30 in.) 116.0 mm (4.57 in.)
F No. 5 Key 930.0 mm (36.61 in.) 15.0 mm (0.59 in.)
G Speaker 1363.5 mm (53.68 in.) 178.0 mm (7.01 in.)
H Receipt 1294.5 mm (50.96 in.) 157.0 mm (6.18 in.)
I Card Reader, Motorised 1207.8 mm (47.55 in.) 138.0 mm (5.43 in.)
J Card Reader, Dip 1207.0 mm (47.52 in.) 87.0 mm (3.43 in.)
K Camera Window 1211.0 mm (47.68 in.) 130.0 mm (5.12 in.)
L Audio Jack Plug 1108.4 mm (43.64 in.) 105.0 mm (4.13 in.)
M Envelope/Cheque/Cash deposit 1017.5 mm (40.06 in.) 116.0 mm (4.57 in.)

G
A
H

I, J
B
K

D L

E
M, E

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-11
Physical Requirements
ATM Dimensions

Topmost Viewable Facia Item 1

The following illustration shows the projected angle from the front
of the standard collar to the topmost viewable facia item.

45
Statement

If the ATM is fitted with a video camera it is strongly recommended


Ambient Lighting 1

that there is a minimum of 200 LUX lighting at floor level within the
area illustrated below. This lighting level conforms to:
● Australian Standard for Automatic Teller Machines (1990)
● Lighting for Automated Teller Machines as prepared by
Illuminating Engineering Society of North America (1997).

1000 mm
(39.4 in.)

1500 mm
(59.1 in.)

Note: A minimum of 200 LUX is recommended for task lighting.

1-12 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Installation and Service Clearances 1

The following illustrations show the recommended areas required


Recommended Clearances 1

for installing and servicing the ATM.

Note: If the ATM is replacing a 5088 installation, the building or


kiosk may need rework or replacement, as the clearance area is
predominantly to the rear of the ATM.

Important Notice to Users 1

If it is likely that the ATM might be fitted with other new modules
as they become available, you should use the recommended
clearances.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-13
Physical Requirements
Installation and Service Clearances

Standard Sleeve Recommended Clearances 1

1000 mm
(39.4 in.)

461 mm
(18.1 in.) 900 mm
(35.4 in.)

Currency Dispenser
1737 mm
(68.4 in.)
Currency Dispenser

120
461 mm
(18.1 in.)

2123 mm
(83.6 in.)

1745 mm
(68.7 in.)
Recommended
Clearance

See
Note 1

Plinth

Note 1: The height of the plinth depends upon the difference in


height between road level and the interior floor. If there is no
difference, as the illustration shows, the plinth must have a height of
325 mm (12.8 in.).

Note 2: If your ATM is configured with a cheque acceptor, it is


recommended that the cheque acceptor bin is removed from the
security enclosure door before opening the enclosure.

1-14 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Short Sleeve Recommended Clearances 1

1000 mm
(39.4 in.)

786 mm
461 mm
(30.9 in.)
(18.1 in.)
Minimum
See Note 1

Currency Dispenser
1737 mm
(68.4 in.)
Currency Dispenser

120
461 mm
(18.1 in.)

2009 mm
(79.1 in.)

1745 mm
(68.7 in.)
Recommended
Clearance

See
Note 2

Plinth

Note 1: The currency dispenser can be serviced without fully


extending its slides, giving a dimension of 786 mm (30.9 in.) as
shown. This can be achieved by pulling the slides until the nose of
the currency presenter is out of the security enclosure.

Note 2: The height of the plinth depends upon the difference in


height between road level and the interior floor. If there is no
difference, as the illustration shows, the plinth must have a height of
325 mm (12.8 in.).

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-15
Physical Requirements
Installation and Service Clearances

Note 3: If your ATM is configured with a cheque acceptor, it is


recommended that the cheque acceptor bin is removed from the
security enclosure door before opening the enclosure.

1-16 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

The following illustrations show the minimum areas required for


Minimum Clearances 1

installing and servicing the ATM. Note that installing the ATM in
the minimum servicing footprint may increase the servicing time for
the unit.

Important Notice to Users 1

If your ATM is fitted with, or is likely to be upgraded with cheque


acceptor, cash acceptor, or dual dispenser, the ATM must be sited
within the minimum clearance area as shown on page 1-22. Also, if
it is likely that the ATM might be fitted with other new modules as
they become available, you should use the recommended
clearances.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-17
Physical Requirements
Installation and Service Clearances

Standard Sleeve Minimum Clearances (Envelope


Depository Module and/or Currency Dispenser) 1

Minimum clearance can be achieved by offering either side


clearance or rear clearance, as shown below.

1222 mm
(48.1 in.)
Severe Environment 1000 mm
Air Intake (39.4 in.)

98 mm 900 mm
(3.9 in.) (35.4 in.)

1246 mm
Currency Dispenser (49.1 in.)
1024 mm
(40.3 in.)
Envelope Depository

111 mm 740 mm
(4.4 in.) (29.1 in.) Side
Clearance
2123 mm
(83.6 in.)
Rear
2345 mm
(92.3 in.) Clearance

1585 mm
(62.4 in.)
Minimum
Clearance
See Note 2

See
Note 1

Plinth

Note 1: The height of the plinth depends upon the difference in


height between road level and the interior floor. If there is no
difference, as the illustration shows, the plinth must have a height of
325 mm (12.8 in.).

1-18 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Note 2: If your ATM is installed within the minimum height


clearance of 1585 mm (62.4 in.) the ceiling will restrict the full
opening of the top-box. If you want to have a clearance above the
top-box when fully open, refer to the recommended clearance.

Note 3: When the ATM is installed within the minimum service


clearance, the 80 Column printer must be removed to service the
keyboard and shutter areas.

Note 4: Your ATM may be fitted with the severe environment


option, which is shown in the illustration (see ATM Dimensions
section for more information). When severe environment is
configured, the 80 Column printer must be removed to service the
module from the rear.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-19
Physical Requirements
Installation and Service Clearances

Short Sleeve Minimum Clearances (Envelope Depository


Module and/or Currency Dispenser) 1

Minimum clearance can be achieved by offering either side


clearance or rear clearance, as shown below.

1222 mm
(48.1 in.)

Severe Environment 1000 mm


Air Intake (39.4 in.)

786 mm
98 mm (30.9 in.)
(3.9 in.) Minimum
See Note 1

1246 mm
Currency Dispenser (49.1 in.)
1024 mm
(40.3 in.)
Envelope Depository

111 mm 740 mm
(4.4 in.) (29.1 in.) Side
Clearance
2009 mm
(79.1 in.) Rear
2231 mm Clearance
(87.8 in.)

1720 mm
(67.7 in.)
Minimum
Clearance
See Note 2

See
Note 3

Plinth

Note 1: The currency dispenser can be serviced without fully


extending its slides, giving a dimension of 786 mm (30.9 in.) as
shown. This can be achieved by pulling the slides until the nose of
the currency presenter is out of the security enclosure.

1-20 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Note 2: If your ATM is installed without an 80 column printer


fitted, the minimum height clearance is 1585 mm (62.4 in.). If
installed at this height, the ceiling will restrict the full opening of the
top-box. If you want to have a clearance above the top-box when
fully open, refer to the recommended clearance.

Note 3: The height of the plinth depends upon the difference in


height between road level and the interior floor. If there is no
difference, as the illustration shows, the plinth must have a height of
325 mm (12.8 in.).

Note 4: When the ATM is installed within the minimum service


clearance, the 80 Column printer must be removed to service the
keyboard and shutter areas.

Note 5: Your ATM may be fitted with the severe environment


option, which is shown in the illustration (see ATM Dimensions
section for more information). When severe environment is
configured, the 80 Column printer must be removed to service the
module from the rear.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-21
Physical Requirements
Installation and Service Clearances

Standard Sleeve Minimum Clearance (Cheque Acceptor


(Type 2) and/or Cash Acceptor (UD-686), or Dual Dispenser) 1

Minimum clearance can be achieved by offering either side


clearance or rear clearance, as shown below. However, if you have a
cheque acceptor, you MUST use the side clearance dimensions.

1222 mm
(48.1 in.)
Severe Environment 1000 mm
Air Intake (39.4 in.)

870 mm
98 mm (34.3 in.)
(3.9 in.) See
Note 1

Cheque Acceptor 1441 mm


Cash Acceptor (56.7 in.)
1219 mm
Currency Dispenser (48.0 in.)

102
306 mm
(12.0 in.)

900 mm
256 mm (35.4 in.)
(10.1 in.) 468 mm Side
(18.4 in.) Clearance
2123 mm
(83.6 in.) Rear
2345 mm Clearance
(92.3 in.)

1585 mm
(62.4 in.)
Minimum
Clearance
See Note 2

See
Note 3

Plinth

1-22 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Note 1: To allow a cheque acceptor to be serviced within the


minimum service clearance area, the rear transport can be pivoted
from its horizontal position to a vertical position as shown below.

Rear Transport

870.0 mm
(34.3 in.)

Cheque Acceptor

Cash Acceptor
(if configured)

Note 2: If your ATM is installed within the minimum height


clearance of 1585 mm (62.4 in.) the ceiling will restrict the full
opening of the top-box. If you want to have a clearance above the
top-box when fully open, refer to the recommended clearance.

Note 3: The height of the plinth depends on the difference in height


between road level and the interior floor. If there is no difference, as
the illustration shows, the plinth must have a height of
325 mm (12.8 in.).

Note 4: If your ATM is configured with a cheque acceptor, it is


recommended that the bin is removed from the security enclosure
door before opening the enclosure.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-23
Physical Requirements
Installation and Service Clearances

Short Sleeve Minimum Clearance (Cheque Acceptor


(Type 2) and/or Cash Acceptor (UD-686), or Dual Dispenser)
Minimum clearance can be achieved by offering either side
clearance or rear clearance, as shown. However, if you have a
cheque acceptor, you MUST use the side clearance dimensions.

1222 mm
(48.1 in.)
Severe Environment 1000 mm
Air Intake (39.4 in.)

870 mm
98 mm (34.3 in.)
(3.9 in.) See
Note 1

Cheque Acceptor 1441 mm


Cash Acceptor (56.7 in.)
1219 mm
Currency Dispenser
(48.0 in.)

102
306 mm
(12.0 in.)
786 mm
(30.9 in.)
256 mm Minimum
(10.1 in.) See Note 2

468 mm
Side
(18.4 in.) Clearance
2009 mm
(79.1 in.)
Rear
2231 mm Clearance
(87.8 in.)

1720 mm
(67.7 in.)
Minimum
Clearance
See Note 3

See
Note 4

Plinth

1-24 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Note 1: To allow a cheque acceptor to be serviced within the


minimum service clearance area, the rear transport can be pivoted
from its horizontal position to a vertical position as shown below.

Rear Transport

870.0 mm
(34.3 in.)

Cheque Acceptor

Cash Acceptor
(if configured)

Note 2: The currency dispenser can be serviced without fully


extending its slides, giving a dimension of 786 mm (30.9 in.) as
shown. This can be achieved by pulling the slides until the nose of
the currency presenter is out of the security enclosure.

Note 3: If your ATM is installed without an 80 column printer


fitted, the minimum height clearance is 1585 mm (62.4 in.). If
installed at this height, the ceiling will restrict the full opening of the
top-box. If you want to have a clearance above the top-box when
fully open, refer to the recommended clearance.

Note 4: The height of the plinth depends on the difference in height


between road level and the interior floor. If there is no difference, as
the illustration shows, the plinth must have a height of
325 mm (12.8 in.).

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-25
Physical Requirements
Installation and Service Clearances

The following illustrations show the minimum clear wall area


Exterior Wall 1

required around the collar (facia surround) for installation and


servicing.

Standard Collar 1

10 mm
(0.4 in.)

45 mm
(1.8 in.)

30 mm 30 mm
(1.2 in.) (1.2 in.)

Note: A standard collar is configured when you order


the 5886 Drive-Up features 240 and 770.

1-26 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installation and Service Clearances

Standard Collar With Advert Light 1

45 mm
(1.8 in.)

45 mm
(1.8 in.)

30 mm 30 mm
(1.2 in.) (1.2 in.)

Note: A standard collar with advert light is configured when you


order the 5886 Drive-Up features 241 and 770.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-27
Physical Requirements
Service Access Panels

Service Access Panels 1

For installations where there is enough room to stand at the


right-hand side of the sleeve (when viewing the ATM from the rear)
there is an access panel on the top-box, as shown below. The panel
can be removed to allow easier access to the keyboard and shutter
areas.

Note: If the severe environment feature is configured, first remove


the fan assembly.

There is another access panel on the left-hand side which is only


accessible if the ATM is installed through a thin wall,
97 mm (3.82 in.) or less. This panel is located on the sleeve, as shown
below.

1-28 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Hole in the Wall

Hole in the Wall 1

The 5886 Drive-Up can be installed through a new hole, or an


existing NCR 5088 or 5688 hole in the wall with minimal rework
required depending on the ATM being replaced, wall thickness and
the local cardholder access legislation.
Customised collars or surrounds made by the owning organisation
may need rework or replacement due to the following installation
requirements.

The physical installation of the 5886 Drive-Up is divided into three


Installation Categories 1

different categories.
1 An installation where a 5886 Drive-Up replaces a 5088. The hole
in the wall must be modified and the plinth must be replaced
with a new one to position the 5886 Drive-Up keyboard at the
optimum height. See page 1-30.

2 An installation where a 5886 Drive-Up replaces a 5688 and


where no modification has been made to the hole in the wall.
The existing plinth must be replaced with a new one to position
the 5886 Drive-Up keyboard at the optimum height. See page
1-32.

Note: The location of the cable access hole in the base of the
ATM will change. Refer to the section “Requirements For The
Floor” for more details.

3 A new installation of a 5886 Drive-Up at the optimum height.


page 1-34.
For cases 1 and 2, an infill panel is required to accommodate the
larger hole used by the previous 5088 or 5688 installation.

If you are installing your ATM through a glass wall you may
Installing Through a Glass require a suitable glass support (normally a steel collar) to sit
Wall 1
between the ATM collar and the glass - the requirement for this
should be determined by the architect. If required, any such support
should be sourced locally.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-29
Physical Requirements
Replacing 5088 With Modifications to Hole in Wall

Replacing 5088 With Modifications


to Hole in Wall 1

It is the responsibility of the owning institute to ensure that the


heights from the road level to the facia items comply with any local
regulations.

Note 1: A standard or advert collar is required at installation.

Note 2: The existing plinth must be replaced with a new one.

Note 3: An infill panel is required. For information on the infill


panel, refer to the section “Infill Panel Dimensions” later in this
chapter. For information on installing the infill panel, refer to
chapter 8.

The standard sleeve 5886 Drive-Up can be installed through a wall


Dimensions for an ATM that is up to 287 mm (11.30 in.) thick.
With Standard Sleeve 1

618.0 mm
(24.33 in.)

Optimum Height 287.0 mm 643.0 mm Hole in Wall


of No.5 Key (11.30 in.) (25.31 in.)
Maximum Wall
Thickness
52.5 mm
930.0 mm (2.07 in.)
(36.61 in.) 792.3 mm
(31.19 in.) ATM Base

Plinth

152.0 mm View from Inside Building


(5.98 in.)
Curb Set-back

Remove Wall Section

1-30 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Replacing 5088 With Modifications to Hole in Wall

The short sleeve 5886 Drive-Up can be installed through a wall that
Dimensions for an ATM is up to 165 mm (6.50 in.) thick.
With Short Sleeve 1

618.0 mm
(24.33 in.)

165.0 mm
Optimum Height (6.50 in.) 643.0 mm Hole in Wall
of No.5 Key Maximum Wall (25.31 in.)
Thickness

52.5 mm
930.0 mm (2.07 in.)
(36.61 in.) 792.3 mm
(31.19 in.) ATM Base

Plinth

Road Level
152.0 mm View from Inside Building
(5.98 in.)
Curb Set-back

Remove Wall Section

Refer to page 1-37 for plinth requirements.


Plinth Requirements 1

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-31
Physical Requirements
Replacing 5688 With no Modifications to the Hole in Wall

Replacing 5688 With no


Modifications to the Hole in Wall 1

It is the responsibility of the owning institute to ensure that the


heights from the road level to the facia items comply with any local
regulations.

Note 1: A standard or advert collar is required at installation.

Note 2: The existing plinth must be replaced with a new one.

Note 3: An infill panel is required. For information on the infill


panel, refer to the section “Infill Panel Dimensions” later in this
chapter. For information on installing the infill panel, refer to
chapter 8

The standard sleeve 5886 Drive-Up can be installed through a wall


Dimensions for an ATM that is up to 287 mm (11.30 in.) thick.
With Standard Sleeve 1

724.0 mm
(28.50 in.)

287.0 mm 624.0 mm
Optimum Height (11.30 in.) Hole in Wall
(24.57 in.)
of No.5 Key Maximum Wall
Thickness

52.5 mm
930.0 mm (2.07 in.)
825.0 mm
(36.61 in.) ATM Base
(32.48 in.)

Plinth

Road Level
152.0 mm View from Inside Building
(5.98 in.)
Curb Set-back

1-32 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Replacing 5688 With no Modifications to the Hole in Wall

The short sleeve 5886 Drive-Up can be installed through a wall that
Dimensions for an ATM is up to 165 mm (6.50 in.) thick.
With Short Sleeve 1

724.0 mm
(28.50 in.)

165.0 mm 624.0 mm
Optimum Height (6.50 in.) (24.57 in.) Hole in Wall
of No.5 Key Maximum Wall
Thickness

52.5 mm
930.0 mm (2.07 in.)
825.0 mm
(36.61 in.) (32.48 in.) ATM Base

Plinth

Road Level
152.0 mm View from Inside Building
(5.98 in.)
Curb Set-back

Refer to page 1-37 for plinth requirements.


Plinth Requirements 1

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-33
Physical Requirements
Installing Through a New Hole

Installing Through a New Hole 1

It is the responsibility of the owning institute to ensure that the


heights from the road level to the facia items comply with any local
regulations.

Note: A standard or advert collar is required at installation.

The standard sleeve 5886 Drive-Up can be installed through a wall


Dimensions for an ATM that is up to 287 mm (11.30 in.) thick.
With Standard Sleeve 1

610.0 mm
(24.02 in.)

287.0 mm 602.0 mm
OptimumHeight Hole in Wall
(11.30 in.) (23.70 in.)
of No.5 Key
Maximum Wall
Thickness

52.5 mm
930.0 mm (2.07 in.)
833.0 mm
(36.61 in.) ATM Base
(32.80 in.)

Plinth

Road Level
152.0 mm View from Inside Building
(5.98 in.)
Curb Set-back

1-34 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Installing Through a New Hole

The short sleeve 5886 Drive-Up can be installed through a wall that
Dimensions for an ATM is up to 165 mm (6.50 in.) thick.
With Short Sleeve 1

610.0 mm
(24.02 in.)

165.0 mm 602.0 mm
Optimum Height (6.50 in.) (23.70 in.) Hole in Wall
of No.5 Key Maximum Wall
Thickness

52.5 mm
930.0 mm (2.07 in.)
833.0 mm
(36.61 in.) (32.80 in.) ATM Base

Plinth

Road Level
152.0 mm View from Inside Building
(5.98 in.)
Curb Set-back

Refer to page 1-37 for plinth requirements.


Plinth Requirements 1

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-35
Physical Requirements
Sealing the Hole in the Wall Against Cold and Water

Sealing the Hole in the Wall Against


Cold and Water 1

To ensure that the temperature around the ATM is maintained


during cold weather, it is important that the wall opening is
prepared correctly. Any cavity in the wall should not extend into
the wall opening, but sealed to provide a flush surface. The gap
between the ATM sleeve and the wall opening should be left clear to
allow air at room temperature to circulate.
To enable a good weather seal to be made between the wall and the
ATM facia, a 25 mm (1 in.) wide smooth surface is required around
the periphery of the wall opening.

Seal any cavity

Do not block air gaps

1-36 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Requirements for the Floor

Requirements for the Floor 1

The following illustrations show a plan of the base of the ATM


Support Plinth 1

(viewed from above) and its relationship with the exterior wall. If a
plinth is used it must be no smaller than the base of the ATM and it
must be constructed of a material, and in such a way, that it is
capable of supporting the weight of the ATM (page 1-42).
Definition: A “plinth” is a platform on to which the ATM is bolted.
This plinth enables the ATM to be installed at the required height
through the wall.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-37
Physical Requirements
Requirements for the Floor

Standard Sleeve Installation 1

Hole in Wall
Front of Wall
287.0 mm
(11.30 in.)
Max. Wall
Thickness 473.0 mm
(18.62 in.)
See note 1
150.0 mm 302.5 mm
(5.91 in.) (11.91 in.)

A A

56.0 mm
(2.21 in.)
800.0 mm 25.0 mm 500.0 mm
(31.5 in.) (0.98 in.) (19.69 in.)

56.0 mm
(2.21 in.)
D
C A A 150.0 mm
(5.91 in.)

105.0 mm 157.5 mm
(4.13 in.) 500.0 mm (6.20 in.)
(19.69 in.)
815.0 mm
(32.09 in.)

15.0 mm
(0.59 in.)

25.0 mm 30.0 mm
(0.98 in.) (1.18 in.)

Detail of hole A

Note 1: When an infill panel is required, this dimension is


461.0 mm (18.15 in.). For information on the infill panel, refer to the
section “Infill Panel Dimensions” later in this chapter. For
information on installing the infill panel, refer to chapter 8.

Note 2: The boundary, marked with a ‘C’, shows the cable access
hole for all cables.

Note 3: The dotted boundary, marked with a ‘D’, shows where the
cable access hole would be on a 5688 being replaced with 5886
Drive-Up.

1-38 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Requirements for the Floor

Short Sleeve Installation 1

Hole in Wall
165.0 mm Front of Wall
(6.50 in.)
Max. Wall
Thickness
359.0 mm
(14.13 in.)
150.0 mm 302.5 mm See note 1
(5.91 in.) (11.91 in.)

A A

56.0 mm
(2.21 in.)
800.0 mm 25.0 mm 500.0 mm
(31.5 in.) (0.98 in.) (19.69 in.)

56.0 mm
(2.21 in.)
D
C A A 150.0 mm
(5.91 in.)

105.0 mm 157.5 mm
(4.13 in.) 500.0 mm (6.20 in.)
(19.69 in.)
815.0 mm
(32.09 in.)

15.0 mm
(0.59 in.)

25.0 mm 30.0 mm
(0.98 in.) (1.18 in.)

Detail of hole A

Note 1: When an infill panel is required, this dimension is


347.0 mm (13.66 in.). For information on the infill panel, refer to the
section “Infill Panel Dimensions” later in this chapter. For
information on installing the infill panel, refer to chapter 8.

Note 2: The boundary, marked with a ‘C’, shows the cable access
hole for all cables.

Note 3: The dotted boundary, marked with a ‘D’, shows where the
cable access hole would be on a 5688 being replaced with 5886
Drive-Up.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-39
Physical Requirements
Mandatory Modifications to Plinth or Floor

Mandatory Modifications to Plinth or


Floor 1

The following modifications must be made to the plinth:

If a concrete plinth is used at installation, a section of the plinth


Concrete Plinth 1

should be cut-out to allow the cables which enter the base of the
ATM to be fitted.
The following illustration shows the size of cut-out required for all
security enclosure options.

If an adjustable plinth is used, holes should be drilled through the


Adjustable Plinth 1

plinth, to allow the cables which enter the base of the ATM to be
fitted.

If the ATM is installed directly on to the floor, without a plinth, the


ATM Installed Directly on cabling must be routed through a channel in the floor. The channel
to the Floor 1
must be large enough to allow the cabling to be routed along the
floor and under the ATM.

Note: If a channel needs to be cut through the floor, this area must
be large enough to allow the cabling to be routed along the floor and
under the ATM.

1-40 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Mandatory Modifications to Plinth or Floor

Hole in Wall

800.0 mm
(31.5 in.) 76.5 mm
(3.01 in.)
81.0 mm
(3.19 in.)

11.0 mm
(0.43 in.)

161.0 mm 815.0 mm
(6.34 in.) (32.09 in.)

50.8 mm
(2.00 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-41
Physical Requirements
Mandatory Modifications to Plinth or Floor

The ATM must be installed on a floor capable of supporting the


Floor Loading 1

maximum weight. Only the maximum weight should be considered


as additional options may be added after installation.
Standard Security enclosure:
● Maximum weight: 835kg (1841.2 lb.)
● Floor loading: 1280.7 kg/m2 (262.3 lb./ft2).

The ATM should be bolted to the floor, through the ‘A’ holes, see
Security Bolts 1

page 1-28, using four bolts with anchor washers. If the ATM is to be
bolted down, the floor or plinth must be capable of withstanding the
loading imposed by the anchor points for the bolts. The bolts and
anchors must be supplied by the owning organisation.
The following is the minimum specification for bolts to secure the
ATM to a plinth or a stone/concrete floor, through the ‘A’ holes:
16 mm (0.63 in.) diameter x 100 mm (3.94 in.) minimum length.

An antistatic floor covering should be used and must be of a type


Floor Covering 1

that will not generate dust or fluff.

1-42 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Infill Panel Dimensions

Infill Panel Dimensions 1

Customised infill panels, made by owning organisations, should


use the following dimensions as a guide:

For a 5088 infill panel, use the following dimensions:


Infill Panel (5088) 1

90.0 mm 620.0 mm
(3.54 in.) (24.41 in.)

995.0 mm
(39.17 in.)
600.0 mm
(23.62 in.)
70.0 mm
(2.76 in.)

800.0 mm 12.0 mm
(31.50 in.) (0.47 in.)

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-43
Physical Requirements
Infill Panel Dimensions

For a 5688 infill panel, use the following dimensions:


Infill Panel (5688) 1

150.0 mm 620.0 mm
(5.91 in.) (24.41 in.)

995.0 mm
(39.17 in.)
600.0 mm
(23.62 in.)
70.0 mm
(2.76 in.)

920.0 mm 12.0 mm
(36.22 in.) (0.47 in.)

1-44 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Physical Requirements
Internal Space Constraint for Fitting a Third Party Video Camera

Internal Space Constraint for Fitting


a Third Party Video Camera 1

If a third party video camera is to be installed, there is a space


constraint to consider. The location of the video camera is directly
behind the camera window. The following dimensions should be
calculated from the centre point on the window, as shown below.

36.0 mm 18.0 mm
(1.42 in.) (0.71 in.)

44.0 mm
(1.73 in.)
Camera Window

Camera Position

44.0 mm
(1.73 in.)

Note 1: The depth constraint, from the rear of the camera window,
is 220 mm (8.66 in.).

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 1-45
Physical Requirements
Internal Space Constraint for Fitting a Third Party Video Camera

1-46 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents
Electrical Requirements

Chapter 2
Electrical Requirements

Power Quality Distribution and Grounding Requirements 2-1


AC Power Requirements 2-1
Input Voltage Setting 2-1
Power Consumption 2-1
Idle Mode 2-1
Under Transaction 2-2
Power Cable 2-2
Grounding Requirements 2-2
Transient Power Loss 2-3
EMI Susceptibility 2-3
EMI Emission 2-3

Communications Requirements 2-4


High Order Communications Cable 2-4
High Order Communications Standard Cable (RS-232) 2-5
Remote Device Cables 2-6
RS-232 Cable 2-6
Remote Status Monitor 2-9
Alarm Interface Cable 2-11
Remote Relay Cable 2-14

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents
Electrical Requirements

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
2

Power Quality Distribution and Grounding Requirements

Power Quality Distribution and


Grounding Requirements 2

Voltage transients, line noise, surges, sags, impulses, and spikes


may be experienced routinely or sporadically. When such
phenomena occur, the use of protective devices, as described in
Attachments A, may be required to ensure proper operation of the
equipment.

The maximum current requirements at the following input voltages


AC Power Requirements 2

are:
● 5.05A at 120V, or 9.10A with severe environment
● 2.01A at 240V, or 4.2A with severe environment.
The maximum inrush current at the following input voltages are:
● 200A peak at 136V
● 150A peak at 257V.

Note: If you are considering upgrading your ATM to include the


cash acceptor, you should be aware that in the event of a power
failure, there is the potential for customers cash to be retained in this
module, and for details of the transaction to be lost. For this reason
NCR do not recommend running a 5886 Drive-Up with a cash
acceptor without an Uninterruptible Power Supply (UPS).

The ATM can operate from the following input mains voltages:
Input Voltage Setting 2

● 90V to 136V at 50/60Hz


● 180V to 264V at 50/60Hz.

A power consumption rate for your ATM can be calculated from the
Power Consumption 2

following information:

Idle Mode 2

● 307 Watts at 120V


● 177 Watts at 240V.

Note: Power consumption is dependent on the configuration of


your ATM.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-1
Electrical Requirements
Power Quality Distribution and Grounding Requirements

Under Transaction 2

● 606 Watts at 120V, or 1092 Watts with severe environment


● 482 Watts at 240V, or 1008 Watts with severe environment.

Note: Power consumption is dependent on the transaction rate of


your ATM.

The ATM is supplied either as a 120V or a 220-240V unit. 120V


Power Cable 2

ATMs are supplied with a power cable fitted with a NEMA type
5-15P power source connector. 220-240V ATMs are supplied with an
unterminated power cable. Information about suitable power
connectors is supplied with the accessories. Power connectors must
be wired as shown below.
The power cable supplied is 3 metres (9 ft. 9.00 in.) in length. If it is
necessary to increase this length to meet site requirements, then the
extension must satisfy local or country regulations.

Note 1: If the ATM being installed is replacing a 5088 installation, it


may be necessary to either lengthen the cable or re-position the
electrical sockets, as the cable access hole is in the security enclosure
and toward the rear of the enclosure.

Note 2: If the ATM being installed is replacing a 5688 installation, it


may be necessary to either lengthen the cable or re-position the
electrical sockets, as the cable access hole is on the other side.

Warning This equipment must be earthed.

Note: The annotations within brackets are included to comply with


United Kingdom legislation and refer to the markings on United
Kingdom three pin plugs.

The ATM operates from a single phase, 3 wire supply; live, neutral
Grounding Requirements 2

and ground. The power requirements of this unit will normally


permit it to operate within existing wiring configurations and from
existing branch mains outlets providing:
1 Where this supply is provided from a general purpose
distribution panel, then the other branch circuits from this panel
must not be used to support heavy inductive loads such as air

2-2 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
Power Quality Distribution and Grounding Requirements

conditioners, elevators, microwave ovens, and so on. Nor may


such equipment be operated on the same branch circuit as the
ATM.

2 If using distribution panels, all branch circuit grounding


conductors must be connected to an insulated ATM strip in the
distribution panel. The grounding conductor from the
distribution panel to the building ground point must be at least
equal in size to the power conductor necessary to supply the
NCR system.

Note: The building ground point can affect data integrity. For
additional information refer to the ‘Data Line Transient Protection’
section of Attachment A.

The voltage loss due to power interruptions must not be more than
Transient Power Loss 2

50% of the nominal value for a maximum of one half cycle at a


maximum rate of 1 every 10 seconds.

The ATM meets EN 55024 (1998) “ITE Immunity Standard”.


EMI Susceptibility 2

The ATM meets FCC CFR 47 Prt 15 Class A and EN 55022 (1998)
EMI Emission 2

Class A requirements for radiated and conducted emission.


The ATM meets EN61000-3-2 (latest revision) Mains Harmonics
(Class A) and EN61000-3-3 (latest revision) Mains Flicker
requirements for conducted emission.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-3
Electrical Requirements
Communications Requirements

Communications Requirements 2

Voltage transients, line noise, surges, sags, impulses, and spikes


may be experienced routinely or sporadically. When such
phenomena occur, the use of protective devices, as described in
Attachment A, may be required to ensure proper operation of the
equipment.
It is the responsibility of the customer to assure that all installation
preparations are complete and in compliance with NCR
specifications and requirements and with all national, state or local
telephone and telegraph regulations and laws.

The high order communications cable type depends upon the


High Order communications system to be used. The following cable may be
Communications Cable 2
required.

Note: Communications cables are not supplied with the ATM. If


these cables are required, it is the customer’s responsibility to have
them installed. The specification for this cable is supplied in the
following section. When producing cables allow for 1.8 metres
(6 feet) of cable within the ATM.

2-4 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
Communications Requirements

High Order Communications Standard Cable


(RS-232) 2

The standard high order communications system supports most


common bit and byte oriented disciplines (synchronous and
asynchronous) with an RS-232 interface.
The interconnecting cable to the remote modem should not exceed
15.24 metres (50 feet) in length, and must conform to the
specification and wiring given on the following diagram.

1, 2 6 5 3 4

1. Connector, 25 way (NCR part no. 006-0005897).


2. Terminal wire, male (NCR part no. 009-0002642).
3. Cable, multiconductor (NCR part no. 007-8907033).
4. Connector (determined by remote device).
5. Shell hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).

CHASSIS GND
1
2 TD.V
3 RD.V
4 RQS.V
5 RFS.V
6 DSR.V
7 SIG.GND
8 RLSD.V

15 TSET.V
17 RSET.V
18 WCA.V
20 DTR.V
22 CI.V

EXT SET.V
24
WIN.V
25

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-5
Electrical Requirements
Communications Requirements

At a point 550mm (21.65 in.) from the connector end of the cable,
remove a 20mm (0.79in.) section of the outer sleeve as shown. At a
further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of
the outer sleeve.

Note: Take care not to cut through the cable shielding when
removing the outer sleeve.

20.0 mm 20.0 mm
(0.79 in.) (0.79 in.)

550.0 mm 660.0 mm
(21.65 in.) (25.98 in.)

The specifications for these cables are supplied below.


Remote Device Cables 2

RS-232 Cable 2

The ATM can have up to two RS-232 outlets which can be


configured to provide an interface for one of two options:
● Remote camera
● Remote card access device.

2-6 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
Communications Requirements

For both options the cable is limited in length to


15.24 metres (50 feet) and must conform to the specification and
wiring given here.

1, 2 6 5 3 4

1. Connector, 25 way (NCR part no. 006-0005897).


2. Terminal wire, male (NCR part no. 009-0002642).
3. Cable, multiconductor (NCR part no. 007-8907033).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).

CHASSIS GND CHASSIS GND


1 1 1
2 TD 2 2 TD
RD RD
3 3 3
RSLD RTS
8 4 8
CTS CTS
5 5 5
RTS RSLD
4 DSR 8 4 DSR
6 DTR 6 6 DTR
20 SIGNAL GND 20 20 SIGNAL
7 7 7

Modemless Cable Adapter RS232 Interface Cable

Note: The modemless cable adapter is supplied with RS-232


interface feature kits. This adapter performs crossover and linking
normally associated with modemless operation. If this linking is not
required, the modemless cable adapter may be removed and the
RS-232 Interface Cable connected directly to the ATM.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-7
Electrical Requirements
Communications Requirements

At a point 300mm (11.81 in.) from the connector end of the cable,
remove a 20mm (0.79in.) section of the outer sleeve as shown. At a
further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of
the outer sleeve.

Note: Take care not to cut through the cable shielding when
removing the outer sleeve.

20.0 mm 20.0 mm
(0.79 in.) (0.79 in.)

300.0 mm 660.0 mm
(11.81 in.) (25.98 in.)

2-8 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
Communications Requirements

Remote Status Monitor 2

The remote status monitor feature is supplied as a complete


assembly and consists of a status indicator unit, 76.2 metres
(250 feet) of cable and a connector.

At a point 380mm (14.96 in.) from the connector end of the cable,
remove a 20mm (0.79in.) section of the outer sleeve as shown. At a
further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of
the outer sleeve.

Note: Take care not to cut through the cable shielding when
removing the outer sleeve.

20.0 mm 20.0 mm
(0.79 in.) (0.79 in.)

380.0 mm 660.0 mm
(14.96 in.) (25.98 in.)

If you are required to shorten the cable, proceed as follows:


1 Remove the cover from the remote status indicator unit.

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-9
Electrical Requirements
Communications Requirements

2 Disconnect the four leads from the indicator, that is E1, E2, E3
and E4.

Red

Yellow

Green

(Green) E1

(Red) E2

(White) E3

(Black) E4

3 Cut the cable to the required length and strip the four wire ends.

4 Connect the wires to the correct terminals.

5 Replace the status indicator cover.

2-10 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
Communications Requirements

Alarm Interface Cable 2

The ATM may optionally be configured to provide an alarm


interface which enables the ATM to be connected to an external
local alarm system. The interface may take the form of one of two
options; a basic alarm system or an enhanced alarm system.
The external alarm system must provide to the ATM, through the
alarm interface cable wiring, a non interruptible, stabilised power
supply with the following specifications:
● 12V +- 2V dc
● 200mA maximum
● Ripple, 5% maximum.
The interconnecting cable to the ATM is similar for both alarm
interface options and must conform to the following specification
and wiring:

1,2 6 5 3 4

1. Connector, 25 Way (NCR part no. 006-0005896)


2. Terminal, wire, female (NCR part no. 009-0002640)
3. Cable, multiconductor (determined by the alarm installed).
4. Connector (determined by remote device).
5. Shell Hood (NCR part no. 006-1500038).
6. Screw retainer (NCR part no. 601-0101584).

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-11
Electrical Requirements
Communications Requirements

At a point 300mm (11.81 in.) from the connector end of the cable,
remove a 20mm (0.79in.) section of the outer sleeve as shown. At a
further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of
the outer sleeve.

Note: Take care not to cut through the cable shielding when
removing the outer sleeve

20.0 mm 20.0 mm
(0.79 in.) (0.79 in.)

300.0 mm 660.0 mm
(11.81 in.) (25.98 in.)

Basic Alarm Interface Cable Wiring


CHASSIS GND
1
SILENT ALARM COMMON *
7
DOOR ALARM N.O.
8
DOOR ALARM N.C..
9
VIBRATION/HEAT COMMON
10
+12V
12
SILENT ALARM N.O. *
19
SILENT ALARM N.C. *
20
DOOR ALARM COMMON
21
VIBRATION/HEAT N.O.
22
VIBRATION/HEAT N.C.
23
+12V RETURN
25
* Optional

2-12 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Electrical Requirements
Communications Requirements

Enhanced and High Security Alarm Interface Cable Wiring


CHASSIS GND
1
TEST TRANSMITTER A
3
TAMPER ALARM N.O.
5
TAMPER ALARM N.C..
6
SILENT ALARM COMMON *
7
DOOR ALARM N.O.
8
DOOR ALARM N.C.
9
COMPOSITE ATTACK COMMON
10
+12V
12
TEST TRANSMITTER B
16
TAMPER ALARM COMMON
18
SILENT ALARM N.O. *
19
SILENT ALARM N.C. *
20
DOOR ALARM COMMON
21
COMPOSITE
. ATTACK N.O.
22
COMPOSITE ATTACK N.C.
23
+12V RETURN
25
* Optional

NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation 2-13
Electrical Requirements
Communications Requirements

Remote Relay Cable 2

The remote relay provides a pair of open contacts, rated at 28 volts


per ampere for both ac and dc supplies, which can be closed to
activate a remote device. The interconnecting cable to a remote
device must conform to the following specification and wiring:

1, 2 3 4

1. Connector, 2 way Mate-N-Lock (NCR part no. 007-9814285).


2. Terminal wire, male (NCR part no. 007-2009663).
3. Cable, multiconductor (NCR part no. 006-5800006).
4. Connector (determined by remote device).

RL1
1
RL2
2

At a point 380mm (14.96 in.) from the connector end of the cable,
remove a 20mm (0.79in.) section of the outer sleeve as shown. At a
further 660mm (25.98 in.), remove another 20mm (0.79 in.) section of
the outer sleeve.

Note: Take care not to cut through the cable shielding when
removing the outer sleeve.

20.0 mm 20.0 mm
(0.79 in.) (0.79 in.)

380.0 mm 660.0 mm
(14.96 in.) (25.98 in.)

2-14 NCR Personas M Series 5886 Drive-Up ATM Site Preparation and Installation
Table of Contents
Environmental Requirements

Chapter 3
Environmental Requirements

Environmental Requirements 3-1


Temperature and Humidity 3-1
Barometric Pressure 3-2
Electromagnetic Compatibility (EMC) and Safety 3-4
EMC Directives 3-4
Immunity Standards 3-4
Acoustics 3-4
Heat Dissipation 3-4
Air Flow 3-4
Temperature Rise 3-4

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Environmental Requirements

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Environmental Requirements
3

Environmental Requirements

Environmental Requirements 3

For the ATM to function correctly the site at which it is to be


installed should meet the following environmental requirements.

The ATM will operate over a range of temperature and humidity.


Temperature and However, continuous operating at or near the range limits or in a
Humidity 3
location where the temperature and humidity change beyond the
specification, should be avoided. The temperature and humidity
ranges are as follows:
Normal operating range (interior to wall environment):
● Temperature: 10oC to 40oC (50oF to 104oF)
● Temperature change rate: 10oC/hour (18oF/hour)
● Relative humidity: 20% to 80%
● Relative humidity change rate: 10%/hour
● Dew point temperature restriction: 26oC (79oF) maximum.

Note: The humidity inside the building is restricted to a maximum


of 30% at an outside temperature of -35oC (-31oF) with a linear
(straight line) relationship between temperature and humidity to a
maximum humidity of 80%.

Normal operating range (exterior to wall environment):


● Temperature: -35oC to 50oC (-31oF to 122oF)
● Temperature change rate: 10oC/hour (18 oF/hour)
● Relative humidity: 10% to 100%
● Relative humidity change rate: 10%/hour.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 3-1
Environmental Requirements
Environmental Requirements

Storage range (up to three months):


● Temperature: -10oC to 50oC (14oF to 122oF)
● Temperature change rate: 15oC/hour (27oF/hour)
● Relative humidity: 10% to 90%
Transit range (up to one week):
● Temperature: -40oC to 60oC (-40oF to 140oF)
● Temperature change rate: 20oC/hour (36oF/hour)
● Relative humidity: 5% to 95%
Extreme power on range (up to one hour):
● Temperature: 0oC to 40oC (32oF to 104oF)
● Temperature change rate: 10oC/hour (18oF/hour)
● Relative humidity: 10% to 95%.

Barometric pressure details are as follows:


Barometric Pressure 3

● Operating and transit limits: 105kPa (15.2 lb. F/in.)


● Equivalent altitude: up to a maximum of
3000 metres (9842 feet).
The ATM will accommodate an external to internal pressure
difference of up to 70 pascal (with the severe environment option
fitted).
How to determine whether the severe environment option is
required
The following equipment is required:
● a gauge which measures pressure with an appropriate scale
(up to 100 pascals)
● a piece of tubing to fit the gauge
● silicon sealant
● suitable wall sealant.

3-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Environmental Requirements
Environmental Requirements

The following procedure should be followed, before the hole in the


wall is created:
1 Drill a hole through the exterior wall where the ATM’s facia is to
be located. The diameter of the hole should be correct to
accommodate the diameter of the tubing being used.

2 Insert the tubing through the hole so that the tube is located
inside the building.

3 Use the sealant to make sure that there are no gaps between the
tubing and the exterior wall.

4 Attach the gauge to the loose end of the tube (that is, on the
inside of the building).

5 Take a note of the pressure reading.

6 Remove the tube and gauge and seal the hole in the wall using a
suitable sealant.

7 If the pressure gauge indicates a negative pressure differential,


then NCR recommend that the ATM to be installed should have
severe environment fitted.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 3-3
Environmental Requirements
Environmental Requirements

The ATM complies with the following standards and directives:


Electromagnetic
Compatibility (EMC) and EMC Directives 3

Safety 3 ● 89/336/EEC “EMC Directive”


● 92/31/EEC “Amending EMC Directive”
● 73/23/EEC “Low Voltage Directive”
● 93/68/EEC “CE Marking Directive”.
The Harmonised EMC Standards are as follows:
● Radiated and Conducted:
● EN 55022 (1998) Class A
● FCC CFR 47 Part 15 Class A.
● Conducted (220V - 240V units):
● EN61000-3-2 (latest revision) Mains Harmonics (Class A)
● EN61000-3-3 (latest revision) Mains Flicker.

Immunity Standards 3

● EN 55024 (1998) “ITE Immunity Standard”.


The Harmonised Safety Standard is as follows:
● EN 60950 “Safety of IT Equipment”.

Sound Power
Acoustics 3

● 65 dB(A) idle
● 68 dB(A) operating.

The heat dissipation of the ATM is 1580kJ/hour (1500 BTU/hour)


Heat Dissipation 3

maximum.

The air flow through the ATM is rated at 0.1 m3/s


Air Flow 3

(212 ft 3/min.).

The temperature rise for air passing through the ATM is 3oC (5.4 oF).
Temperature Rise 3

3-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Decal Requirements

Chapter 4
Decal Requirements

Decal Dimensions 4-1


Card Orientation Window 4-2
Card Acceptance Decal 4-3
Clear Window 4-3
Advert Light 4-4
Entry/Exit Slot Decals 4-5

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Decal Requirements

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Decal Requirements 4

Decal Dimensions

Decal Dimensions 4

The following illustrations provide the specifications and locations


for the decals which you may wish to fit to the front of your ATM.

Advert Light

Receipt Exit

Statement Exit
Card Reader
(Motorised/Dip)

Cash Exit/Deposit Entry/ Cash Exit/Deposit Entry


Cheque Entry Cash Deposit

Cash Deposit

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 4-1
Decal Requirements
Decal Dimensions

If the window next to the Card Reader entry/exit slot is to be


Card Orientation Window 4

customised to indicate card orientation, the card/decal to be


inserted into the window should be of the following dimensions.

3.0 mm (0.12 in.)


radius on all corners

86.0 mm
(3.39 in.)

54.0 mm
(2.13 in.)

The insert should be a maximum of 0.75 mm (0.029 in.) thick.


The decal should not be made of absorbent material if the front of
the ATM is likely to be subjected to rain.

4-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Decal Requirements
Decal Dimensions

If a decal is required to advertise which cards can be used in the


Card Acceptance Decal 4

ATM, it should be positioned on the side wall of the ATM facia. The
decal can by any size, providing it fits onto this area.

If a deposit feature is not configured, then the front of the deposit


Clear Window 4

blank moulding will have a large clear window. If an insert is to be


made to go behind the window it should be of the following
dimensions.

1.0 mm (0.04 in.)


radius on all corners

55.0 mm
(2.17 in.)

169.0 mm
(6.65 in.)

The insert should be a maximum of 0.8 mm (0.03 in.) thick. NCR


recommend that the insert be made from one of the following
materials:
● Polycarbonate
● Polyester
● Paper.

Note: Paper is not recommended if the front of the ATM is likely to


be subjected to rain.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 4-3
Decal Requirements
Decal Dimensions

The following illustration shows dimensions for an advert light


Advert Light 4

decal. These dimensions are based on a decal being applied to the


flat inside area of the advert light panel.

130.0 mm
(5.12 in.)

575.0 mm
(22.64 in.)

4-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Decal Requirements
Decal Dimensions

The front of the ATM has recesses for decals to identify the entry
Entry/Exit Slot Decals 4

and exit slots. The following are guidelines to the decal sizes. The
decals should be a maximum of 0.5 mm thick and it is
recommended that they be made from Textured Polycarbonate with
3M 467 High Performance MP adhesive.

Note: A combination of your application and screen graphics can


be used as an alternative to indicate the cash/media exit slot.

Decal dimensions for:


STATEMENT
RECEIPT
CASH MEI Area of Decal to be
ENVELOPE Transparent to Allow
CHEQUE Light to Pass Through

59.0 mm
R 4.0 mm (2.32 in.) 4.0 mm
(0.16 in.) (0.16 in.)
12.0 mm
(0.47 in.)

2.0 mm 50.0 mm 2.0 mm 2.0 mm


(0.08 in.) (1.97 in.) (0.08 in.) (0.08 in.)
118.0 mm
(4.65 in.)

Decal dimensions for


CARD

86.0 mm
(3.39 in.)
See Note

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 4-5
Decal Requirements
Decal Dimensions

4-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Installation Accessories and Planning Check List

Chapter 5
Installation Accessories and Planning
Check List

Installation Accessories 5-1

Planning Check List 5-2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Installation Accessories and Planning Check List

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Installation Accessories and Planning Check List
5

Installation Accessories

Installation Accessories 5

When installing your ATM it is recommended that you have the


following items available:
● Pincers/claw hammer to remove staples/nails from around the
pallet
● Pozi drive screwdrivers (various sizes)
● Small flat blade screwdriver
● Hacksaw - only required to configure passbook printer
● To fit fixing bolts:
● UL safe - 19 mm (3/4 in.) ring/open-ended combination
spanner and socket
● CEN Grade III or CEN LGAI Security enclosure -
27 mm (1 1/8 in.) socket with a maximum outside diameter
of 33 mm (1 5/16 in.)
● 7 mm (9/32 in.) ring/open-ended combination spanner or
socket to fit the standard or advert facia light
● 10 mm (3/8 in.) ring/open-ended combination spanner for bolt
heads
● 7 mm (9/32 in.) nut spinner for M4 nuts
● Lifting/moving device. Lifting trolleys must have a maximum
toe plate length of 380 mm (14.96 in.) and a minimum toe plate
width of 120 mm (4.72 in.)
● Cutter to cut cable ties
● Packing to protect the exterior of the ATM while on a trolleys.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 5-1
Installation Accessories and Planning Check List
Planning Check List

Planning Check List 5

To assist you in preparing your site for the arrival of your ATM we
provide here a check list of the various procedures that you should
carry-out prior to the arrival of your ATM. The procedures given
are listed in chronological order, starting with the procedure that
you should do first.

Activity

Select site and make scaled floor plan

Ensure correct environmental conditions

Establish all contractor and vendor related schedules

Check communication line requirements

Plan application development

Check floor plan and make any alterations

Install additional electrical outlets (if required)

Prepare site for data communication

Arrange for designing and printing of overlays/


decals

Order technical publications

Order media supplies

Plan operator training (optional)

Ensure data comms. equipment is installed and tested

Ensure installation accessories are available

5-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Installation Procedure

Chapter 6
Installation Procedure

Introduction 6-1
Installation Steps 6-1
Site Preparation 6-1
Tools Required For ATM Installation 6-1
Moving the ATM 6-2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Installation Procedure

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Installation Procedure6

Introduction

Introduction 6

The installation of the NCR 5886 Drive-Up Automated Teller


Installation Steps 6

Machine (ATM) can be divided into several steps:


● Moving the ATM
● Unpacking the ATM
● Inspecting the ATM for damage
● Removing the ATM from the pallet
● Fitting the severe environment (if required)
● Fitting the infill panel to the wall (if required)
● Fitting the cheque receiving bin (if configured)
● Positioning the ATM through the hole in the wall
● Fitting the collar
● Sealing to the outside wall
● Bolting the ATM to floor or plinth
● Removing the internal packaging
● Connecting cables to the ATM
● Configuring the ATM
● Applying decals to the facia.
These steps are described in detail in the chapters that follow.

Before installing your ATM make sure that the installation site
Site Preparation 6

conforms to the specifications given in Chapter 1 to Chapter 5 of this


publication.

To install the ATM you will require a number of tools. These are
Tools Required For ATM listed in Chapter 5.
Installation 6

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 6-1
Installation Procedure
Introduction

The ATM will be mounted on a pallet and contained in a cardboard


Moving the ATM 6

crate.
Move the ATM to its installation site using lifting trolleys. To reduce
the chance of damaging the ATM, and the premises, the ATM
should be moved with its packaging intact.
Details of the ATM dimensions, packaging dimensions and
clearances required for moving the ATM in a confined space can be
found in Chapter 1.

6-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Preparing the ATM For Installation

Chapter 7
Preparing the ATM For Installation

Removing the External Packaging From the ATM 7-1


Inspecting the ATM For Damage 7-1
Installation Report Form 7-2

Opening the ATM 7-3


How to Open the ATM 7-3

How to Unlock and Lock the Standard Security Enclosure 7-5


Keylocks 7-6
Combination Locks 7-6
Combination Lock and Separate Keylock 7-8

Controlled Access Electronic Lock 7-12


Controlled Access Electronic Lock (Type 1) 7-13
Controlled Access Electronic Lock (Type 2) 7-15

Electronic Lock with Time Delay 7-21


Unlocking 7-21
Locking 7-22
Emergency Opening Procedure 7-23

Removing the ATM From Its Pallet 7-24

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Preparing the ATM For Installation

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Preparing the ATM For Installation
7

Removing the External Packaging From the ATM

Removing the External Packaging


From the ATM 7

Before removing the external packaging, examine it for signs of


damage which may have occurred during transit. Make a note of
any external damage for inclusion in a damage report. See the next
section for details on reporting damage.
When the ATM is approximately in its position for installation,
remove the external packaging as follows:
1 Lever out the staples from around the base of the crate and then
lift the crate from the pallet.

2 Remove the cardboard collar and plastic cover.

3 Remove any kit packages.

4 Remove all pieces of tape from the exterior of the ATM.

After unpacking the ATM, inspect it for any signs of damage.


Inspecting the ATM For
Damage 7
If the ATM is damaged a report should be made in accordance with
the following procedures:
● Customers in the USA should refer to the Branch Practices
manual and report the damage on:
● Marketing communications document
No. 73-130, file location 2-20-57
● Marketing communications document
No. 71-273, file location 2-70-40
● Other customers should use one of the following procedures:
● Customers who are required to arrange their insurance
locally should have the claim processed locally. A separate
report of damage should be made to Inventory Return
Control, Dayton
● Customers who have insurance arranged by NCR Insurance
Department, Dayton, must report the damage on Form F-
2100 (Notice of Damage) to NCR Insurance Department and
send a copy to Inventory Return Control.
The addresses for NCR Insurance and Inventory Return Control are:
● Risk Management and Insurance, NCR Corporation, Dayton,
Ohio 45479, USA.
● Inventory Return Control, International Field Engineering
Support, NCR Corporation, Dayton, Ohio 45479, USA.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-1
Preparing the ATM For Installation
Removing the External Packaging From the ATM

The Installation Report Form delivered with the ATM should


Installation Report Form 7

always be completed and returned. Make sure that you report any
problems in the following areas:
● Malfunction of the ATM or any of its devices
● Internal or external defects arising as a result of handling or
transit damage
● Missing or damaged accessories. All the accessories are fitted at
the appropriate feature inside the ATM.

7-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
Opening the ATM

Opening the ATM 7

Before you open the ATM, remove the tape from the security
enclosure door, handles, dials and top-box.
The key to open the top-box is shipped inside an envelope, which is
taped to the ATM.
The key to open the security enclosure is taped to the base-plate of
the 80-column printer.

To open the ATM, proceed as follows:


How to Open the ATM 7

1 Turn the top-box key clockwise.

Note: The key is shipped inside the document bag secured to the
outside of the unit.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-3
Preparing the ATM For Installation
Opening the ATM

2 Open the top-box door upwards, until the gas struts are fully
extended.

3 Unlock the security enclosure.

7-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

How to Unlock and Lock the


Standard Security Enclosure 7

The standard security enclosure of your ATM will have a locking


handle plus one lock (a primary lock), or two locks (a primary and a
secondary lock). The possible lock types for primary and secondary
locks are as follows:

● Primary lock types:


● Keylock
● Combination lock
● Combination lock with silent alarm
● Combination lock with keylock
● Secondary lock types:
● Keylock
● Combination lock
● Combination lock with silent alarm
● Combination lock with electronic override.

Note: The make of lock fitted (Standard or Sargent and Greenleaf)


depends on the configuration of the ATM. The procedures for
opening and closing the various types of lock are the same for both
makes.

The following illustration shows the relative positions of primary


and secondary locks.
Primary Lock

0
90 10
80

20
70

30

60 40
50

Locking Handle

Secondary Lock

0
90 10
80

20
70

30

60 40
50

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-5
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

If you have a primary and a secondary lock fitted to your ATM they
must be unlocked in the following order:
1 Unlock the secondary lock.

2 Unlock the primary lock.

3 Use the handle to retract the bolt and open the door.
The primary and secondary locks must be locked in the following
sequence:
1 Close the door and use the handle to operate the bolt.

2 Lock the primary lock.

3 Lock the secondary lock.

The pair of keylock keys supplied with your ATM have been pre-cut
Keylocks 7

to a random factory-set combination. If one key should get lost, then


you should get a new pair of keys and then change the keylock
setting.

How to Unlock a Keylock 7

To unlock a keylock, insert the key into the lock and turn it
clockwise as far as it will turn.

How to Lock a Keylock 7

To lock a keylock, turn the key counterclockwise as far as it will turn


and then remove the key.

Three variants of combination lock may be fitted to your ATM:


Combination Locks 7

● Basic combination lock


● Combination lock with integral keylock
● Combination lock with a silent alarm option.
All the variants of the combination lock are three-number
combination locks.
The locks are precision locks, therefore, extreme care must be taken
to align combination numbers with the index.
Turn the dial slowly and steadily. If, after turning the dial the
correct number of revolutions, any number is turned beyond the
index, the entire series of combination numbers must be re-dialled.
Do not turn the dial back to regain a proper alignment of the
number and index, because each time a selected number is aligned
with the index a revolution is counted.

7-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

The procedures for unlocking and changing the combination on a


combination lock are the same regardless of whether the lock is a primary
or secondary lock.
Opening Index
Changing Index

0
90 10

80

20
70
Dial

30
60 40
50

Factory Setting 7

If the combination lock is set at the original factory setting of 50, you
unlock it as follows, dialling on the opening index:
1 If a keylock is fitted to the combination lock, insert the key into
the lock and turn it clockwise.

2 Turn the dial a minimum of four turns counterclockwise and


stop on 50.

3 Turn the dial slowly clockwise until the bolt retracts. The lock is
now open. Use the handle on the door to retract the door bolt
and open the door.

Customer Setting Combination 7

If the combination has been set at a three-number combination, for


example 36-82-44, unlock it as follows:
1 If a keylock is fitted to the combination lock, insert the key into
the lock and turn it clockwise.

2 Turn the dial counterclockwise, passing the first number (36)


three times, stop on the first number (36) the FOURTH time.

3 Turn the dial clockwise, passing the second number (82) twice,
and stop on the second number (82) the THIRD time.

4 Turn the dial counterclockwise, passing the third number (44)


once, and stop on the third number (44) the SECOND time.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-7
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

5 Turn the dial clockwise until the bolt retracts. The lock is now
open. Use the handle on the door to retract the door bolt and
open the door.

How to Operate the Silent Alarm 7

The silent alarm is triggered, if fitted, by adding 10 to the first


number of the combination. For example if the first number was 34,
dial 44 to trigger the silent alarm. Dial the next two numbers of the
combination as normal, the combination lock will open as normal
but the alarm will have been triggered.

How to Lock the Combination Lock 7

To lock the combination lock, turn the dial at least four complete
turns counterclockwise. If a keylock is fitted to the combination
lock, turn the dial until 0 is in line with the opening index and then
turn the key counterclockwise and remove it from the lock.

How to Change the Combination 7

Detailed instructions on how to change the combination of a lock


are inside the security enclosure.

Unlocking 7

Combination Lock and On arrival at the site, the combination lock is set at the original
Separate Keylock 7

factory setting of 50. To unlock the security enclosure, proceed as


follows:
1 Turn the dial of the combination lock until 0 is under the index
mark.

2 Turn the dial of the combination lock counter-clockwise until 50


is under the index mark for the FOURTH time.
Index Mark

Note: Combination locks are precision locks, therefore, extreme


care must be taken to align combination numbers with the index.
Turn the dial slowly and steadily. If any of the numbers in the
combination is turned beyond the index, the entire series of
numbers must be re-dialled.

7-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

3 Turn the dial clockwise until 0 is under the index mark or until it
stops. The combination lock is now open.

4 Insert the key into the keylock and turn it clockwise to unlock
the keylock.

5 Turn the locking handle clockwise through approximately 45o to


retract the door bolt. The door is now unlocked.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-9
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

Locking 7

To close and lock the security enclosure proceed as follows:


1 Close the door.

2 Turn the locking handle counterclockwise through


approximately 45o to the vertical position to engage the door
bolt.

3 Turn the key in the keylock counterclockwise and then remove


the key.

4 Lock the combination lock by turning the dial at least four


complete turns counterclockwise.

Customer Setting Combination 7

If the combination has been set at a three-number combination, for


example 36-82-44, unlock it as follows:
1 If a keylock is fitted to the combination lock, insert the key into
the lock and turn it clockwise.

2 Turn the dial counterclockwise, passing the first number (36)


three times, stop on the first number (36) the FOURTH time.

3 Turn the dial clockwise, passing the second number (82) twice,
and stop on the second number (82) the THIRD time.

4 Turn the dial counterclockwise, passing the third number (44)


once, and stop on the third number (44) the SECOND time.

5 Turn the dial clockwise until it stops. The lock is now open. Use
the handle on the door to retract the door bolt and open the
door.

7-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock the Standard Security Enclosure

How to Lock the Combination Lock 7

To lock the combination lock, turn the dial at least four complete
turns counterclockwise. Turn the dial until 0 is in line with the
opening index and then turn the key counterclockwise and remove
it from the lock.

How to Change the Combination 7

Detailed instructions on how to change the combination of a lock


are inside the security enclosure.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-11
Preparing the ATM For Installation
How to Unlock and Lock an Electronic Lock

How to Unlock and Lock an


Electronic Lock 7

To unlock the security enclosure proceed as follows:


Unlocking 7

1 With the keypad in its vertical position, enter the first six digits
of the combination (set to 123456 when shipped from factory). If
the sequence is entered correctly the lock will beep and the LED
flash. If the lock has been set to operate on a single combination,
proceed to step 3.

2 If the lock is set to operate on a dual combination, enter the


second six digits of the combination (set to 456789 when shipped
from factory). If the sequence is entered correctly, the lock will
beep and the LED flash.

3 Turn the keypad clockwise to unlock the lock.

7-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock an Electronic Lock

4 Turn the keylock clockwise to unlock the lock.

5 Turn the safe handle counterclockwise to open the door.

Note: If when entering a combination you enter the wrong


combination 4 times, a 5 minute time delay period is activated.
During this time the LED on the lock will flash red at 10 second
intervals. You must wait until the end of the 5 minute period before
attempting to enter the correct combination.

Note: If fitted, the silent alarm may be activated by entering one


number higher or lower for the last digit of a combination. For
example, if the combination was 1-2-3-4-5-6, entering 1-2-3-4-5-5 or
1-2-3-4-5-7 would activate the silent alarm.

Note: Repeated beeping of the lock during an opening sequence


indicates that the lock battery requires to be replaced. If the lock
keypad is completely “dead”, that is, it makes no sound or flashes,
follow the emergency opening procedure to open the lock prior to
having the battery replaced.

To lock the security enclosure proceed as follows:


Locking 7

1 Close the security enclosure door and turn the handle clockwise.

2 Turn the keylock counterclockwise

3 Turn the keypad counterclockwise until the keypad is vertical.


The door should now be locked.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-13
Preparing the ATM For Installation
How to Unlock and Lock an Electronic Lock

If the keypad is completely “dead”, that is it does not flash or beep,


Emergency Opening it is an indication that the lock battery requires to be replacing. To
Procedure 7
open the lock when it is in this condition you must hold a new 9 volt
alkaline battery against the terminals of the lock. The larger battery
terminal must be against the larger of the lock terminals. The battery
must be held in place while carrying out the normal procedures for
opening the lock.

7-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

How to Unlock and Lock a


Controlled Access Electronic Lock 7

Note: For ATMs with security enclosures fitted with a Kaba Mas
(Mas-Hamilton) controlled access electronic lock, refer to the
following Kaba Mas Group publications for details of how to set up
and manage the operations of the lock:

● CENCON System 2000 Access Control System


● Getting Started Guide
● Supervisor Guide
● Special Supervisor Guide
● FLM Dispatcher Guide
● Route Dispatcher Guide
● CENCON 2000 System Guide.
These publications can be purchased from the following Order
Point:
Kaba Mas Corporation
749, W. Short Street
LEXINGTON
Kentucky
40508
Tel: (1) (1) 859 253-4744
Toll Free (USA Only) 888 959-4715
Fax: (1) 859-225-2655

Note: For the attention of Customer Service Manager.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-15
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

Your ATM may be configured with a controlled access electronic


lock Type 1 or Type 2. The following diagram distinguishes
between the two types.

Type 2
5
Type 1 3 4 0
2
1 89
6 7
*#

Unlocking 7

Controlled Access To unlock a security enclosure with a controlled access electronic


Electronic Lock (Type 1) 7

(type 1) in Bank Mode (1 User), proceed as follows:


1 Spin the knob on the lock.

Note: Rotating the knob generates enough power within the lock to
allow it to operate for 90 seconds after the rotation stops. The LCD
powers down after 40 seconds. Upon power up, the LCD will
provide instructions for the user to follow while opening the
enclosure.

Cencon Lock

Locking Handle

Keypad

LCD

Touch Key
Reader

Knob
(Opening/Closing)

7-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

2 Keep spinning the knob until "EC" appears on the LCD and
beeps are heard.

3 Enter personal combination number (or the factory default


number (50-25-50) using the keypad.

4 "IPI" (Input Personal Identifier) will appear on the LCD.

5 Touch the personal identification key to the key reader.

Note: The lock processor will generate a combination number and


compare the user entered combination number with the generated
combination number.

6 If the combination number and the generated combination


number match the LCD will display "Opr" and beeps will be
heard. Turn the knob clockwise to open the lock and retract the
locking bolt. The security enclosure door can now be opened.

If the combination numbers do not match, a lightning bolt


symbol (to indicate a security violation) will appear on the LCD.
If this occurs, follow your in-house security procedures for this
condition.

Locking 7

To lock a security enclosure with a Kaba Mas controlled access


electronic lock (Type 1), proceed as follows:
1 Close the security enclosure door.

2 Turn the electronic lock knob counterclockwise to close.

3 Spin knob (to power up the electronic lock) until beeps are
heard.

4 "IPI" will appear on the LCD.

5 Touch personal identification key to the key reader.

6 "EOP" (End of Operation) will appear on the LCD.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-17
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

The controlled access electronic lock (Type 2), can also be fitted
Controlled Access with, or without a sub-lock on the cheque acceptor bin. The possible
Electronic Lock (Type 2) 7
combinations of locks are:
● Master lock
● Master lock with sub-lock
To unlock a security enclosure with a master lock and one sub-lock,
you will require the following:
● Personal Identifier key (PI key) - issued by the Key Management
Centre (KMC).
● 6-digit access code - obtained from the KMC.

Unlocking the Master Lock 7

To open the master lock, proceed as follows:


1 Contact the KMC.

2 Give requested details to verify your identity to the KMC.

3 Specify which areas, on the ATM, you want to access.

4 Take note of the 6-digit access code (three pairs of two),


allocated by the KMC.

5 Unlock and open the exterior of the ATM.

7-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

6 Spin the lock dial counterclockwise to charge the lock, until EC


is displayed on the LCD.

Note: If DL (Dial Left) is displayed, you must only turn the dial
to the left (counterclockwise).

Keypad

4 5
LCD

2 3 0
1 8 9
6 7
*# Home Position

Key Reader

Dial
(Opening/Closing)

7 Turn the dial to the home position.

8 Enter the 6-digit access code provided by the KMC on the


keypad.

9 IPI should be displayed on the LCD.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-19
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

10 Hold the PI key against the key reader to verify a valid user
identity. If sub-lock access is required, the appropriate authority
is passed to the PI key at this stage.

Keypad

LCD 5
4
3 0
1 2 89
6 7
*#
Key Reader

PI Key

Dial
(Opening/Closing)

11 If the correct 6-digit code has been entered and a valid PI key
has been pressed against the key reader, OPr will be displayed
on the LCD.

Note 1: If an incorrect code or PI key is used and there is a bad PI


key contact, a lightning bolt symbol will be displayed on the
LCD, indicating an error condition.

If the error condition was caused by a bad PI key contact, YOU


HAVE ONE MORE ATTEMPT AT OPENING THE LOCK. If the
error condition occurs after the 2nd attempt, contact the KMC
immediately.

12 Turn the lock dial a quarter turn (90o) clockwise to release the
bolt.

13 Open the security enclosure.

7-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

Locking the Master Lock 7

To lock the master lock, proceed as follows:


1 Close the security enclosure.

2 Turn the lock dial counterclockwise to activate the bolt and


charge the lock until IPI is displayed on the LCD.

3 Hold the PI key against the key reader.

4 Take a note of the unique 4-digit close code that is displayed, as


it will be required by the KMC.

5 Close the exterior of the ATM.

6 Contact the KMC.

Note: Ensure that all the locks and doors on the ATM are closed
and locked before contacting the KMC.

7 Verify identification.

8 Provide the 4-digit close code to the KMC.

9 The KMC will inform you that either the code is correct or give
you the correct procedure to follow if the close code is wrong.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-21
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

Unlocking the Sub-Lock (if configured) 7

To unlock the sub-lock, proceed as follows:


1 Carry out Steps 1 to 10 of “Unlocking the Master Lock”.

Note: The code displayed on the LCD will depend on which areas
of the ATM you requested access to.

2 Hold the PI key against the key reader of the sub-lock.

PI Key

Key Reader
Knob

LED

The LED flashes three (3) times. You have eight (8) seconds to
unlock the sub-lock by turning the knob clockwise to release the
catch. If the knob is turned back to its original position, you will
need to contact the KMC for another access code.

Note: The knob cannot be turned before the LED flashes. After
turning, the catch remains in position until the lock is closed.

3 Remove the cheque acceptor bin.

7-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
How to Unlock and Lock a Controlled Access Electronic Lock

Locking the Sub-Lock (if configured) 7

To lock the sub-lock, proceed as follows:


1 Replace the cheque acceptor bin firmly. Ensure the bin is fully
home and the knob is turned fully counterclockwise to lock the
bin in place.

2 Hold the PI key against the key reader of the sub-lock until the
LED has flashed four (4) times. This indicates the lock is closed.

3 On the master lock, turn the lock dial counterclockwise to


charge the lock until IPI is displayed on the LCD.

4 Hold the PI key against the key reader of the master lock.

5 Take a note of the unique 4-digit close code that is displayed, as


it will be required by the KMC.

6 Close the exterior of the ATM.

Note: Ensure that all the doors and locks on the ATM are closed
and locked before contacting the KMC.

7 Contact the KMC.

8 Verify your identification.

9 Provide the 4-digit close code to the KMC.

10 The KMC will inform you that either the code is correct or give
you the correct procedure to follow if the close code is wrong.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-23
Preparing the ATM For Installation
Removing the ATM From Its Pallet

Removing the ATM From Its Pallet 7

To remove the ATM from its pallet using lifting trolleys proceed as
follows:
1 Unlock and open the ATM security enclosure.

2 Use a 19 mm (3/4 in.) spanner and the same size socket to


remove the four bolts attaching the ATM to the pallet.

3 Close the security enclosure.

7-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Preparing the ATM For Installation
Removing the ATM From Its Pallet

4 Put the lifting trolleys on either side of the pallet and insert the
toes of the trolleys under the ATM.

5 Strap the trolleys to the ATM and insert packing where


necessary to protect the ATM’s paintwork. Pump up both
trolleys to lift the ATM clear of the pallet. Slide the pallet out
from under the ATM.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 7-25
Preparing the ATM For Installation
Removing the ATM From Its Pallet

6 Place the safety boards under the ATM. Lower the ATM until it
is resting on the safety boards.

7 Adjust the trolleys, straps and packing, ensuring the trolleys are
as near as possible to the ATM.

8 Pump up both trolleys to lift the ATM clear of the safety boards.
Slide the safety boards out from under the ATM.

9 Move the ATM to the installation site.

7-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Installing the ATM – Physical Installation

Chapter 8
Installing the ATM – Physical
Installation

Introduction 8-1
Installation Categories 8-1
Connecting Cables 8-1

Fitting the Severe Environment Parts 8-2


Dismantling the Severe Environment Parts 8-2
Removing the 80-Column Printer 8-4
Removing the Side-Access Service Panel 8-7
Fitting the Severe Environment Parts 8-11
Sealing the ATM 8-17

Fitting a Cheque Acceptor Bin (If Configured) 8-22


Cheque Acceptor Bin With a Keylock 8-22
Cheque Acceptor Bin With a Sub-Lock 8-24

Positioning the ATM 8-27

Fitting An Infill Panel 8-28


Infill Panel (5088) 8-28
Infill Panel (5688) 8-29

Fitting the Collar 8-31


Fitting the Standard Collar With Facia Light 8-31
Fitting the Standard Collar With Advert Light 8-36

Sealing the Collar and Bolting the ATM to the Plinth 8-44

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Installing the ATM – Physical Installation

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Installing the ATM – Physical Installation
8

Introduction

Introduction 8

The physical installation of 5886 Drive-Up is divided into three


Installation Categories 8

different categories.
For information on the installation categories, refer to Chapter 1.

If the ATM is being installed within a minimum footprint clearance


Connecting Cables 8

area, due to limited side clearance, cable connections must be


carried out before the unit is moved into its final location. If
however, the ATM is located in a recommended footprint clearance
area (or more), cable connections can be carried before or after the
final siting of the unit.
If required, refer to “Connecting Cables to the ATM” and connect
cables before proceeding with the installation.

Caution The design of the plinth must be such that it will not damage the
cables which exit the ATM through the base of the security
enclosure. For more details, refer to Chapter 1.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-1
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

Fitting the Severe Environment Parts 8

The severe environment module is shipped detached from the


ATM. It is recommended that the module is fitted to the ATM prior
to installation through the wall.
To fit the module proceed as follows:

When dismantling the severe environment module, make sure that


Dismantling the Severe you retain all parts, including screws, in preparation for fitting to
Environment Parts 8
the ATM.
1 Remove the severe environment parts from their packaging.

2 Disconnect the fan and heater connections from the connector


box.

8-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

3 Disconnect the heater harness from the heater element


connections.

1 2

4 Remove the three M4 nuts securing the fan assembly to the side
access panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-3
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

To remove the 80-column printer, proceed as follows:


Removing the 80-Column
Printer 8
1 Open the top-box of the ATM.

Note: The following illustrations show a letter quality document


statement printer on a standard sleeve ATM, however, the steps for
removing the printer are the same in all cases.

2 Pull and hold the latch stud upwards and push the operator
interface to the left until it reaches its second stop position.

Note 1: You will know when the operator panel has reached the
second stop position, as the plunger will sit in a second hole at the
opposite end of the track.

Note 2: If your ATM is the short sleeve version, the operator panel
will raise automatically when the top-box is opened.

8-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

3 Press the green latch and using the green handle, slide the
printer forwards, until its slides are fully extended.

4 Disconnect the power and SDC connectors from the printer.


Feed the cables back through the hole in the metalwork and cut
the three cable ties securing the cables to the printer.

Note: The location and number of cables and cable ties may
differ from that shown below.

5 Push the printer back into the ATM until it clicks into place

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-5
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

6 Remove the two screws securing the printer to the support plate.

7 Slide the printer towards the rear of the ATM to release the
mushroom studs from the key-holes.

8 Remove the printer from the ATM.

Warning: The printer is heavy. Make sure that you have an unobstructed
area in which to move and place it before you lift it from the
ATM.

8-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

To remove the side-access service panel, proceed as follows:


Removing the Side-Access
Service Panel 8
1 Disconnect the terminals from the auto-supervisor switch and
remove the switch from the bracket. Retain the switch for using
in the same position later.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-7
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

2 Remove the M6 locknut from the stud on the top-box and retain
it for using in the same position later.

8-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

3 Remove the circlip securing the gas-strut and relocate it on the


stud on the top-box. Secure it with the M6 locknut removed
previously.

Caution: Ensure the top-box is supported before relocating the gas-strut.

4 Remove the securing stud from the gas-strut’s original location


and retain it for using in the same position later.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-9
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

5 Remove the side-access service panel by slackening three M4


locknuts at the rear, and removing the two M6 screws on the
base. Retain the two screws for using in the same position later.

6 Remove the side-access service panel.

8-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

To fit the severe environment parts, proceed as follows:


Fitting the Severe
Environment Parts 8
1 Fit the new side-access service panel with the two retained M6
screws at the base and then tighten the three M4 locknuts at the
rear.

2 Re-fit the gas-strut securing stud to the new side-access service


panel and move the piston on to the stud.

3 Secure the gas-strut on the stud with a circlip.

Warning: Ensure that the circlip is secure before proceeding to the next step.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-11
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

4 Connect the heater harness to the terminals. Ensure that both


terminals are pushed through the hole in the side-access service
panel and that the grommet is located in the hole.

1 2

8-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

5 Fit the severe environment fan assembly to the side-access


service panel with the three M4 locknuts. Do not tighten the
locknuts.

Note: Ensure that the fan and heater connections project


through the cut out in the side-access service panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-13
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

6 Secure the heater and fan harnesses to the bracket on the side-
access service panel using a cable tie.

7 Fit the severe environment housing assembly to the two studs


on the side wall of the top-box and secure with two M4 locknuts.

8-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

8 Fit the entry panel to the housing assembly with two M4 x 6


countersunk screws at the top, and two M4 x 6 screws at the
bottom.

9 Slide the severe environment fan assembly towards the entry


panel. Tighten the three locknuts.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-15
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

10 Connect the fan, heater and thermostat connections to the


terminal box. Ensure that the grommets are located in the slots
in the connector box.

11 Fit the connector box assembly to the fan assembly using one M4
screw.

8-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

12 Connect the AC power harness to the connector box.

13 Refit the auto-supervisor switch to the bracket on the side-access


service panel. Reconnect the harness to the terminals.

The final stage of fitting the severe environment module, is to seal


Sealing the ATM 8

the ATM to prevent negative pressure within the ATM.

14 Cut the foam gaskets into sections and fit between the existing
gaskets on the top-box.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-17
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

15 Fit the two rubber seals to either side of the top-box.

16 Cover the gap between the top-box and the sleeve on both sides
with adhesive tape. Cover the speaker slots on the facia with
adhesive tape.

17 Open the security enclosure.

8-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

18 Fit the adhesive gasket (445-0655433) to the flange on the right


hand side of the security enclosure and the adhesive gasket (445-
06455434) to the side wall on the left hand side of the security
enclosure.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-19
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

19 Fit the brackets to the top and bottom of the security enclosure
door using four M6 x 12 round head screws.

Note 1: Use the fixing holes to secure the brackets to the security
enclosure.

Note 2: If external alarms are fitted, it may not be possible to fit


these brackets.

8-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Severe Environment Parts

20 Remove the adhesive backing from the seals (445-0655684) and


fix them to the brackets that were fitted previously.

21 Replace the printer, securing it with the two screws which were
removed earlier.

22 Connect the power and SDC connectors and secure the cables
with cable ties.

23 If your ATM is the standard sleeve version, return the operator


panel to its home position.

Caution: If the operator panel is not returned to its home position, closing the
top-box may damage the paintwork on the front of the panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-21
Installing the ATM – Physical Installation
Fitting a Cheque Acceptor Bin (If Configured)

Fitting a Cheque Acceptor Bin (If


Configured) 8

The cheque acceptor bin is shipped detached from the ATM. The
types of bin locks and mountings are:
● cheque acceptor bin with a keylock
● cheque acceptor bin with a sub-lock

Keylock
Mounting

Knob Sub-lock
LED

Cheque Acceptor
Bin

To fit a cheque acceptor bin with a keylock, proceed as follows:


Cheque Acceptor Bin With
a Keylock 8
1 Remove bin parts from their packaging.

2 Insert and turn the key clockwise to release the latch and remove
the bin from the mounting bracket.

8-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting a Cheque Acceptor Bin (If Configured)

3 Secure the mounting bracket to the outside of the security


enclosure door with the three M6 x 8 screws and two Mono-
drive screws.

Note: The head of the mono-drive screw has two quarters of the
head removed allowing the screw to be driven in one direction
only.
M6 Screws

Mono-drive
Screws

4 Rest the bin on the mounting bracket and guides, then push
firmly home.

Mounting

Guide

Cheque Acceptor Bin

Security Enclosure
Door

5 Remove the key from the keylock.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-23
Installing the ATM – Physical Installation
Fitting a Cheque Acceptor Bin (If Configured)

To fit a cheque acceptor bin with a sub-lock, proceed as follows:


Cheque Acceptor Bin With
a Sub-Lock 8
1 Remove the bin parts from their packaging.

2 Separate the bin from the mounting bracket.

3 Remove and retain the three M4 x 6 screws from inside the safe
door cover, then remove the cover.

Screw

Security Door
Cover

Screws

8-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting a Cheque Acceptor Bin (If Configured)

4 Secure the mounting bracket to the outside of the security


enclosure door with the three M6 x 8 screws and the two
Mono-drive screws.

Note: The head of the mono-drive screw has two quarters of the
head removed allowing the screw to be driven in one direction
only.

M6 Screws

Mono-drive
Screws

5 Feed the power cable through the safe door as shown below.
Connect the 2 pin connector to the power harness leading to the
PC Core. Connect the 9 pin connector to the Sublock Interface
Box.

PC Core
Connector

Sublock
Interface Box

6 Replace the safe door cover.

7 Carry out steps 1 and 2 of “Unlocking the Sub-Lock” in


Chapter 7.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-25
Installing the ATM – Physical Installation
Fitting a Cheque Acceptor Bin (If Configured)

8 Rest the cheque acceptor bin on the mounting bracket and


guides, then push firmly home. Ensure the knob is turned fully
clockwise to lock the bin in place.

Mounting

Guide

Cheque Acceptor Bin

Security Enclosure
Door

9 Carry out steps 2 to 10 of “Locking the Sub-Lock” in Chapter 7.

8-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Positioning the ATM

Positioning the ATM 8

To position the ATM through the hole in the wall proceed as


follows.
1 Using the lifting trolleys, move the ATM onto the plinth and
through the hole in the wall so that the sleeve protrudes at the
other side.

Note: The holes in the base of the security enclosure should line up
with the fixing holes in the plinth.

2 Remove the ATM from the lifting device.

Warning If you have to slide the ATM off the lifting trolleys, take care that
the ATM does not fall over.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-27
Installing the ATM – Physical Installation
Fitting An Infill Panel

Fitting An Infill Panel 8

An infill panel is required when installing 5886 Drive-Up into a hole


used by a previous 5088 or 5688 installation.

For fitting a 5088 infill panel, proceed as follows:


Infill Panel (5088) 8

1 Place the infill panel over the sleeve and mark its outline on the
wall.

2 Using the infill panel as a template, mark centre points for the
four fixing holes.

3 Remove the infill panel.

4 Drill fixing holes and insert the M6 wall fixings. Remove the
bolts from the fixings.

5 Replace the infill panel and check its position before finally
bolting it to the wall using the M6 wall bolts and washers.

6 Seal the outer edge of the panel to the wall using silicone
sealant.
The hole in the wall is now prepared for the installation of the ATM.

8-28 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting An Infill Panel

For fitting a 5688 infill panel, proceed as follows:


Infill Panel (5688) 8

1 Place the infill panel over the sleeve and mark its outline on the
wall.

2 Remove the infill panel.

3 Using lifting trolleys, move the ATM back from the hole in the
wall.

4 Loosely fit the two mounting brackets to the infill panel using
four M6 screws, four washers and four nuts.

5 Place the infill panel over the hole in the wall, ensuring that it is
placed within the outline drawn previously.

6 With the help of an assistant or with the use of tape, temporarily


secure the infill panel to the wall.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-29
Installing the ATM – Physical Installation
Fitting An Infill Panel

7 If required, adjust the two mounting brackets until they are tight
against the inside face of the wall.

Wall Mounting Bracket

8 Using the two mounting brackets as templates, mark centre


points for the six fixing holes.

9 Remove the infill panel.

10 Drill fixing holes and insert the M6 wall fixings. Remove the
bolts from the fixings.

11 Replace the infill panel and check its position before finally
bolting it to the wall using the M6 wall bolts.

12 Tighten the two mounting brackets to the infill panel using the
four screws, four washers and four bolts that were loosely fitted
previously.

13 Seal the outer edge of the panel to the wall using silicone
sealant.

14 Using the lifting trolleys, move the ATM through the hole in the
wall so that the sleeve protrudes at the other side.
The hole in the wall is now prepared for the installation of the ATM.

8-30 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

Fitting the Collar 8

The following sections describe the two different collar assemblies


available for the 5886 Drive-Up:
● Standard collar with facia light
● Standard collar with advert light

These instructions should be followed for installations where a 5886


Fitting the Standard Collar Drive-Up is installed at the NCR recommended height.
With Facia Light 8

1 Fix the vertical collar mounting brackets to the sleeve using four
M4 x 6 countersunk thread forming screws on each side. The
brackets are not interchangeable and must be fitted as shown,
with the tabs facing forward.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-31
Installing the ATM – Physical Installation
Fitting the Collar

2 Fix the bottom collar mounting bracket to the sleeve, as shown,


using three M4 x 6 thread forming screws.

Note: Ensure the bracket tabs are aligned with the lower
bracket tabs on the vertical collar mounting brackets.

8-32 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

3 Fit the “U” shaped collar piece to the brackets by sliding it onto
the bracket tabs, as shown.

1 2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-33
Installing the ATM – Physical Installation
Fitting the Collar

4 Apply silicone sealant to both sides of the lower collar piece, as


shown.

5 Slide the top collar assembly into position.

6 Using a damp cloth, wipe any excess silicone sealant from the
join between the lower and top collar.

8-34 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

7 Fix the top collar assembly with four M4 x 10 screws through the
white light panel and into the mounting bracket.

8 Insert the facia light fluorescent tube and turn it until its contacts
are tightly held.

9 Hook the facia light window under the lip of the top collar piece
and swing it up into position. Fit a clip over the facia and secure
it with four M3 countersunk machine screws.

10 Proceed to the section “Sealing the Collar and Bolting the ATM
to the Plinth”.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-35
Installing the ATM – Physical Installation
Fitting the Collar

These instructions should be followed for installations where a 5886


Fitting the Standard Collar Drive-Up is installed at the NCR recommended height.
With Advert Light 8

Note: The standard collar with advert light requires a decal. Fix the
advert decal to the surface of the light panel before fitting the collar.
Make sure that the panel is clean, dry and dust free prior to
applying the decal. The decal may have to be fitted to the inside or
outside of the light panel depending on the decal design.
1 Fix the left and right collar mounting brackets to the sleeve
using four M4 x 6 countersunk thread forming screws on each
side. The brackets are not interchangeable and must be fitted as
shown, with the tabs facing forward.

8-36 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

2 Fix the bottom collar mounting bracket to the sleeve as shown,


using three M4 x 6 thread forming screws.

Note: Ensure the bracket tabs are aligned with the lower
bracket tabs on the vertical collar mounting brackets.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-37
Installing the ATM – Physical Installation
Fitting the Collar

3 Fit the “U” shaped collar piece to the brackets by sliding it onto
the bracket tabs, as shown.

1 2

8-38 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

4 Apply silicone sealant to both sides of the lower collar piece, as


shown.

5 Slide the top advert collar assembly into position. Push the two
harness connectors from below and through the hole in the
bottom right hand side of the collar.

6 Using a damp cloth, wipe any excess silicone sealant from the
join between the lower and top collar.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-39
Installing the ATM – Physical Installation
Fitting the Collar

7 Fix the top advert collar assembly with four M4 x 10 screws


through the white light panel and into the mounting bracket.

8-40 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

8 Fit the two harness connectors to the top advert collar and
secure with two M3 x 20 screws and two nuts.

Caution: Do not over-tighten the two screws as this may cause damage to the
harness connectors.

9 Connect the harness earth lead to the earth stud on the top
advert collar and secure with a M4 nut.

10 Insert the facia light fluorescent tube and turn it until its contacts
are tightly held.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-41
Installing the ATM – Physical Installation
Fitting the Collar

11 Clip in the advert light window.

Caution Ensure that the window is secured at the top and down both sides,
and that both the bottom clips are engaged.

8-42 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Fitting the Collar

12 Hook the facia light window under the lip of the top collar piece
and swing it up into position. Fit a clip over the facia and secure
it with four M3 countersunk machine screws.

13 Proceed to the section “Sealing the Collar and Bolting the ATM
to the Plinth”.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-43
Installing the ATM – Physical Installation
Sealing the Collar and Bolting the ATM to the Plinth

Sealing the Collar and Bolting the


ATM to the Plinth 8

The final stage of installation is to seal the ATM to the wall and bolt
it down. The following picture shows the standard collar with
advert light, however, the method of fitting the weather seal is the
same in all cases.
1 Apply four strips of self-adhesive weather seal gasket to the rear
faces of the collar, and two small strips to the rear of the lower
and top collar join.

Caution: Ensure the top gasket strip is positioned at the top edge of the collar
and forms a “T” on top of the vertical strips, to prevent water
gathering behind the collar.

2 Pull the ATM hard against the building wall to compress the
weather seal.

8-44 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Physical Installation
Sealing the Collar and Bolting the ATM to the Plinth

3 Open the security enclosure and bolt the ATM to the


floor/plinth.

Note: Bolts are not provided with the unit, they must be
supplied by the owning organization. You will require:

● 4 bolts 16 mm (0.63in.) diameter x 120 mm (4.72in.) long


● 4 anchor washers to fit the bolts. These must be at least 3 mm
(0.12in.) thick and have a maximum outside diameter of
40mm (1.57in.) and an inner diameter of 18 mm (0.71 in.).

4 Trim off any excess weather seal.

5 Seal the top and vertical edges of the collar to the wall, or infill
panel, using silicone sealant from the collar kit box.

Caution: Do not seal the bottom edge of the collar.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 8-45
Installing the ATM – Physical Installation
Sealing the Collar and Bolting the ATM to the Plinth

8-46 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Installing the ATM – Internal Packaging and Cables

Chapter 9
Installing the ATM – Internal
Packaging and Cables

Removing the Internal Packaging 9-1


Module Locations 9-2
Top-Box 9-3
Security Enclosure 9-4
Operator Panel 9-5
Currency Dispenser 9-6
PC Core 9-8
Magnetic Card Reader/Writer 9-9
Receipt and Journal Printers 9-10
80 Column Printer Release Latch 9-11
Statement Printer 9-12
Depository and Depository Bin 9-14
Cash Acceptor 9-16
Cheque Acceptor 9-17

Connecting Cables to the ATM 9-18


Power Cable 9-18
Connecting All Other Cables 9-21

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Installing the ATM – Internal Packaging and Cables

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Installing the ATM – Internal Packaging and Cables
9

Removing the Internal Packaging

Removing the Internal Packaging 9

This section describes how to remove the internal packaging from


all modules. Ignore those steps which apply to modules not
configured into the ATM.

Note: The amounts and types of packing may be subject to change


without notice.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-1
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

The following illustrations show some of the possible locations of


Module Locations 9

modules in the 5886 Drive-Up ATM.


Card Reader Top-Box Digital Audio Volume Control
CD Rom Drive Supervisor/
Operator Panel
3.5 in. Disk Drive (Short Sleeve)

PC Core
Statement Printer

Receipt / Journal Supervisor/


Printer Operator Panel
(Standard Sleeve)
Card Capture Bin

Power On/Off Switch

Envelope
Depository

Currency Dispenser

Currency Purge Bin

Currency Cassette

Security Enclosure Door


Power Supply Depository Bin

Cheque Acceptor
(See Note 1)

Cash Acceptor
(See Note 1)

Note 1: Modules in the security enclosure (that is, the envelope


dispenser/depository, currency dispenser or cash acceptor) may be

9-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

located on either the left- or the right-hand side, depending on the


configuration of your ATM. The cheque acceptor may only be
located on the right-hand side.

Note 2: The illustrations throughout this manual show a standard


sleeve ATM, where the operator panel is located in front of the
statement printer.

Remove the two foam blocks from inside the top-box.


Top-Box 9

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-3
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove and retain the plastic document bag taped to the bottom of
Security Enclosure 9

the security enclosure.

9-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

If your ATM is the standard sleeve version, remove the foam blocks
Operator Panel 9

from the front and rear of the operator panel. Remove the tape from
the release plunger.

Note: The ATM is shipped with the operator panel out of its
operational position. After removing the packaging, slide the panel
to the right hand side until the plunger slots into its home position.

If your ATM is the short sleeve version, remove the foam block from
the front of the operator panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-5
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

If your ATM is fitted with dual dispenser, you should follow the
Currency Dispenser 9

procedures described below to remove the packing material from


both dispensers.
Remove the tape from around the dispenser latch-handle.

Note: The position and appearance of the latch handle may differ
from that shown.

Remove the foam block and tape from the front of the currency
dispenser.

9-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove tape from cassette latches on right-hand side and across the
cassette and purge bin handles.

If your ATM has a dispenser with four cassettes, pull out the bottom
cassette and remove the packaging from beneath the dispenser
chassis.

Remove the strip of weather seal from inside the purge bin.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-7
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove and retain the power cable and small plastic bag taped to
PC Core 9

the PC Core. Remove the foam block from behind the PC Core.

9-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove tape from the release plunger for the open card capture bin
Magnetic Card and the foam block from inside the bin.
Reader/Writer 9

Remove the cable tie and tape from the card capture bin (secure
container shown).

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-9
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove the tape and foam packing piece from the printer tray
Receipt and Journal release latch.
Printers 9

Remove the pieces of tape securing the paper rolls to the modules.

9-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove the tape and foam packing from the printer release latch.
80 Column Printer Release
Latch 9

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-11
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove the tape from both printer carriage levers.


Statement Printer 9

Remove the tape from the following areas of the printer:


● Print engine latch
● Thumbscrews at each side of the knife assembly
● Transport shutter (type 2 printer only)

9-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

● Rear of the paper hopper


● Paper hopper latch
● Thumbscrew at the paper guides
● Thumbscrew on the underside of the paper hopper.

If the ATM is configured with an overhead operator panel, remove


the foam block shown in the following illustration.

If the ATM is configured with a receipt printer, remove the foam


block between the printers.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-13
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

From the front of the facia, remove the sheet of cardboard from the
statement printer aperture.

Your ATM may be fitted with the envelope depository located on


Depository and the opposite side from what is shown in the illustrations, however
Depository Bin 9
the procedure for removing the packing material is the same.
Remove the tape from the depository latch. Remove the foam block
from the front of the depository.

9-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove three pieces of tape from the depository bin.

Remove the box containing the ink jet print head from behind the
deposit bin. Remove the tape from the envelope dispenser.

Refer to the publication, “NCR 5886 Operator Manual”, B006-6194,


for details of how to fit the print head cartridge.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-15
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove the tape and foam block from the latch handle, and the tape
Cash Acceptor 9

and foam form the bottom of the cash acceptor.

Note: The position and appearance of the latch handle may differ
from that shown.

Remove tape and foam blocks from the locations shown below.

9-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Removing the Internal Packaging

Remove tape from the around cheque acceptor latch. Remove the
Cheque Acceptor 9

foam block from the front of the cheque acceptor.

Note: The position and appearance of the latch handle may differ
from that shown.

Remove tape from the locations shown below.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-17
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

Connecting Cables to the ATM 9

The cables used to make connections to the ATM must conform to


the cable specifications and details of preparation provided in
Chapter 2.

Note: Because there is a limited side clearance when the ATM is


being installed within a minimum footprint clearance area, cable
connections must be carried out before the unit is moved into its
final location. If however, the ATM is located in a recommended
footprint clearance area, cable connections can be carried before or
after the final siting of the unit.

Cables to be connected to the ATM fall into two categories:


● Power cable, not requiring additional grounding
● All other cables, i.e. Remote Relay, Remote Status Indicator,
Alarms Interface Cable and High Order RS-232 Communication
cables, require additional grounding by means of a “P” clamp.

Caution Cables must be grounded where indicated to make sure that the
ATM meets EMC requirements.

To connect the power cable to your ATM, proceed as follows:


Power Cable 9

1 Open both the top-box and the security enclosure of the ATM.

9-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

2 Check that the mains ON/OFF switch is in the OFF position


(pressed in at the 0 side).

0 1

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-19
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

3 Remove the two M4 nuts securing the two cover plates to the
cable entry bracket. Remove the cover plates.

1 2

9-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

4 Insert the end of the power cable through the hole in the base of
the security enclosure.

5 Connect the power cable to the socket on the power supply on


the security enclosure wall.

Warning Make sure that the power supply cable is not connected to the AC
outlet while you are connecting it to the ATM.

6 If you are connecting cables after installing the ATM, connect


the power cable to the AC outlet. Otherwise, leave the power
cable disconnected from the AC outlet until after the ATM is
installed and bolted down.

7 If you have no other cables to connect, proceed from step 9 in


the next section. Otherwise, proceed to the next section.

To connect a Remote Relay, Remote Status Indicator, High Order


Connecting All Other RS-232 Communication or Alarms Interface cable to the ATM
Cables 9
proceed as follows:

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-21
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

1 Check that the mains ON/OFF switch is at the OFF position


(pressed in at the 0 side).

0 1

9-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

2 Insert the ends of the cables through the hole in the base of the
security enclosure. Pull sufficient cable through the hole to
allow the connector to be fed through the matching hole in the
top of the security enclosure.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-23
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

3 Connect the communications cables to the appropriate


connectors on the panel.

9-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

4 Take the earth studs and screw them into the threaded holes on
the inside wall of the security enclosure as shown.

P Clamp

Earth
Stud M4 Nut

Note 1: The studs are packed in a plastic bag attached to the PC


Core chassis.

Note 2: Ensure the area around the two threaded holes and the
earth stud base is clean for a good electrical contact.

5 Tighten the studs down on to the base using a 10 mm (3/8 in.)


spanner or socket.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-25
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

6 Clip the appropriate sized “P” clamp around the stripped


section of each cable to be connected, then, using a
7 mm (9/32 in.) spanner, attach the clamp to the earth stud with
the M4 nuts supplied.

Note 1: If the cable has not been stripped, refer to the instructions in
Chapter 2.

Note 2: The largest clamp should be attached to the earth stud first,
then the second largest and so on. Attach all the clamps to the stud
even if some are not used – they may be required at a later date.

M4 Nuts Separating
and securing groups
of two cable clamps
3.4 mm (0.13 in.)
Clamps facing upward

4.5 mm (0.18 in.)


Clamps facing downward

6.0 mm (0.24 in.)


Clamps facing downward

Earth Stud in Security


Enclosure wall

9-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

7 After all the cables have been connected, tie them together using
the two cable ties provided.

8 Screw the cable ties to the inside wall of the security enclosure
with two M6 screws, as shown.

Cable Tie

M6 Screw

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 9-27
Installing the ATM – Internal Packaging and Cables
Connecting Cables to the ATM

9 Replace the cover plates, ensuring the studs locate in the slots.
Slide the plates toward each other, overlapping one with the
other, and secure with the two M4 nuts.

1 2

10 Switch on the power at the AC outlet and then at the ATM.

11 Close the security enclosure and top-box.

9-28 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Configuring the ATM

Chapter 10
Configuring the ATM

Introduction 10-1

Currency Cassette Configuration 10-2

Device Configuration 10-3

Communications Configuration 10-4


Self-Service Support 10-4
S4I 10-4

Currency Dispenser Configuration 10-5


Strapping 10-5

Currency Cassette Configuration 10-6

40-Column Printer Configuration 10-7


Thermal Receipt and Journal Printers 10-7
Basic Configuration 10-8
Advanced Configuration and Calibration 10-8
Dot-Matrix Journal Printer 10-12

80-Column Printer Configuration 10-13


Adjusting DIP Switch Settings 10-14
Adjusting Jumper JP1 (Type 2 Printer only) 10-16
Adjusting Hopper Paper Guides 10-16
Adjusting the Contrast 10-22
Capture Bin Threshold 10-23

Envelope Dispenser 10-24


Adjusting the Spacer Length 10-28

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Configuring the ATM

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Configuring the ATM
10

Introduction

Introduction 10

After you have completed the hardware installation of the ATM


there are certain configuration procedures that must be performed.
These depend upon which modules are installed in the ATM.

Note: All dot-matrix printers are pre-fitted with secured paper and
ribbons but paper will have to be loaded or fed into the transport.

Refer to the publication, NCR 5886 Operator Manual, (B006-6194), for


details of how to load supplies and how to fit the print head
cartridges.
The features which may require configuration are:
● Currency cassette
● Device Configuration
● Communications
● Currency Dispenser
● Printers:
● 40-Column printers
● 80-Column printer
The configuration of these features is described in the following
sections.
After completing the installation and configuration of the ATM, if
your system software is Self-Service Support, refer to publication
Self-Service Support, System Application User Guide, (B006-6167), for
details of system initialization. If your system software is S4I, refer
to publication Supervisor Functions, (B006-4718) instead.
After installation and testing, complete and return the Installation
Report Form delivered with the ATM.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-1
Configuring the ATM
Currency Cassette Configuration

Currency Cassette Configuration 10

The currency cassettes should be configured as described in


publication NCR Currency Cassette Owner’s Manual, (B006-1297).

10-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
Device Configuration

Device Configuration 10

The ATM has a number of devices which need to be configured at


installation.
If your ATM runs Self-Service Support, then configuration is done
using the System Application. Refer to the NCR publication
Self-Service Support System Application User Guide (B006-6167).
If your ATM runs S4I system software, then configuration can be
done by referring to the NCR publication Supervisor Functions,
(B006-4718).

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-3
Configuring the ATM
Communications Configuration

Communications Configuration 10

If you intend to use communications, then you must configure the


software and hardware. The procedure for configuring your ATM
depends on whether your ATM runs Self-Service Support or S4I:

Configuration is described in the NCR publication APTRA


Self-Service Support 10

Communications Feature User’s Guide, (B006-0012).

Note: Before you can start to configure the communications, you


must have Self-Service Support installed on your ATM.

For information on NCR certified Communications boards, please


refer to the following NCR Intranet site, or contact your local
support representative:
http://www.dundee.ncr.com/INFOPROD/Software&Services.htm

Configuration is described in the NCR publication Supervisor


S4I 10

Functions (B006-4718).

Note: Before you can configure communications in the ATM, you


must build and load the applications software on to the ATM. The
procedures for building and loading software can be found in NCR
publication Building a Load Disk, (B006-1797).

To configure communications you will require the protocol


identification code. If you order communications software, the
appropriate documentation, including information on codes, is
automatically sent. For more information visit the following NCR
Intranet site.
http://www.dundee.ncr.com/INFOPROD/Software&Services.htm

You will also require the communications common and connection


parameters and these must be supplied by the owning organisation.

10-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
Currency Dispenser Configuration

Currency Dispenser Configuration 10

When the 5886 ATM is shipped with a currency dispenser, the


currency dispenser is pre-configured at the factory and should not
require configuration at installation time. Configuration would,
however, be required if the control board had to be replaced or the
contents of NVRAM were found to be corrupt.

The strapping associated with the 5886 and NID currency dispenser
Strapping 10

control boards has the following default position:


● First dispenser, SDC command switch pack (U16) - set switches
1 to 8 to off for normal running
● Second dispenser, SDC command switch pack (U16) - set switch
1 to on and switches 2 to 8 to off for normal running.

Note: The second dispenser, switch pack settings are only valid
when there are two dispensers installed.

D1
Diagnostic
LEDs
D8
SW1
Diagnostic
Switches
SW8

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-5
Configuring the ATM
Currency Cassette Configuration

Currency Cassette Configuration 10

The currency cassettes should be configured as described in


publication NCR H-8015-STD1-01/02-08 Currency Cassette Owner’s
Manual, (B006-1297).

10-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
40-Column Printer Configuration

40-Column Printer Configuration 10

The ATM may be fitted with up to two 40-column printers – a


thermal receipt printer and either a thermal or dot-matrix journal
printer.

Note: Full details of all configuration options can be found in


chapter 13 of the NCR publication Service Aids Mini-Manual,
(BFM0-0547).

The thermal printers are configured using DIP switches, RESET and
ENTER (SET) buttons and feedback from status LEDs. An EEPROM
on the interface PCB stores most configuration data.
The dot-matrix printer is configured using DIP switches.

Note: The following adjustments must be performed by a customer


engineer.

All the necessary switches and LEDs are accessible through holes in
Thermal Receipt and the interface PCB cover:
Journal Printers 10

SW1
(ENTER (SET))
SW2
LED’s (RESET)
{

DSW2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-7
Configuring the ATM
40-Column Printer Configuration

Adjustments to the following functions can made using DIP switch


Basic Configuration 10

DSW2:
● Black Mark mode – switch 1
● 5670 Emulation – switch 2
● Receipt and/or Journal printer installed – switches 3 & 4.
These adjustments do not update EEPROM data.
To adjust these functions set switches 1 to 4, as appropriate,
following the table below:
DIP switch DSW2 Switch Setting
Function 8 7 6 5 4 3 2 1
Receipt printer - 0 0 0 0 x x x 1
Black Mark mode ON (default)
Receipt printer - Black Mark mode 0 0 0 0 x x x 0
OFF
Report 5670 Emulation (default) 0 0 0 0 x x 0 x
Report TEC Emulation 0 0 0 0 x x 1 x
Installed printers - invalid setting 0 0 0 0 0 0 x x
Installed printers - Receipt printer 0 0 0 0 0 1 x x
only
Installed printers - Journal printer 0 0 0 0 1 0 x x
only
Installed printers - both printers 0 0 0 0 1 1 x x

Note: 0 = off, 1 = ON, x = Don’t care.

Receipt Form Length setting, Character Set selection and Black


Advanced Configuration Mark Calibration involve updating the EEPROM data.
and Calibration 10
Configuration of these functions is made using DIP switch DSW2.
Configuration is carried out as follows:

Receipt Form Length 10

The Receipt Form length can be set to any number of lines between
24 (default) and the maximum of 55.
1 Make a note of the current DSW2 DIP switch settings.

2 Set DSW2 switch 6 to ON.

3 Set DSW2 switches 1 to 5 to add the required number of lines to


the default value of 24.

10-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
40-Column Printer Configuration

switch 1 = ON : adds 1 line


switch 2 = ON : adds another 2 lines
switch 3 = ON : adds another 4 lines
switch 4 = ON : adds another 8 lines
switch 5 = ON : adds another 16 lines

For example: to make the form length 35, set the switches like
this:

default:..................... 24
switch 1 = ON adds . 1
switch 2 = ON adds . 2
switch 3 = OFF adds 0
switch 4 = ON adds . 8
switch 5 = OFF adds 0

TOTAL: ................... 35

4 Press the RESET button SW2.

5 Press and hold the ENTER (SET) button SW1 until the four
LEDs blink. The new form length is now stored in the EEPROM.

6 Restore the previously noted DSW2 DIP switch settings and


press the RESET button SW2.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-9
Configuring the ATM
40-Column Printer Configuration

Character Set 10

This setting applies to both the Receipt and Journal printers.


1 Make a note of the DSW2 DIP switch settings.

2 Set the DSW2 DIP switches as shown:

Switch Setting
Function 8 7 6 5 4 3 2 1

International Character Set (Default) 0 0 0 1 1 0 0 1


Arabic Character Set 0 0 0 1 1 0 1 0

Note: 0 = off, 1 = ON.

3 Press the RESET button SW2.


The four LEDs blink – the character set data is now stored in the
EEPROM.

4 Restore the previously noted DSW2 DIP switch settings and


press the RESET button SW2.

Black Mark Calibration 10

1 Make a note of the DSW2 DIP switch settings.

2 Ensure that the Receipt printer is properly loaded with suitable


paper.

3 Set the DSW2 DIP switches as shown:

Switch Setting
Function 8 7 6 5 4 3 2 1

Black Mark Calibration 0 0 0 1 0 1 0 1

Note: 0 = off, 1 = ON.

10-10 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
40-Column Printer Configuration

4 Press the RESET button SW2. Wait until the LEDs have finished
flashing then press the Paper Feed button. The printer feeds
paper, calibrates the black mark sensor and stores the new data
in the EEPROM.

The four LEDs blink to confirm successful calibration. If all four


LEDs do not blink – interpret the error from the pattern of the
blinking LEDs:

Error condition LED 1 LED 2 LED 3 LED 4

Paper out off off BLINK BLINK


S S

Black mark too wide or not found BLINK off off BLINK
S S

Unable to calibrate (unknown BLINK off BLINK BLINK


error) S S S

EEPROM data is only updated when calibration is successful.

5 Restore the previously noted DSW2 DIP switch settings and


press the RESET button SW2.

6 To confirm a successful calibration, press the RESET button and


then immediately press and hold the paper feed button. The
printer will produce a configuration printout, for example:

<Receipt printer>

F/W ROM version 1.60


ANK CG version 1.00

Sensor level
ON OFF TH
BDS 0772 0143 0457

- DIP switches -
1 = Black mark mode
2 = 5670 emulation
3 = Receipt printer

Check the Sensor level ON and OFF values: if they are both
“0000” then the calibration was not successful and the EEPROM
data was not changed.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-11
Configuring the ATM
40-Column Printer Configuration

The illustration below shows a dot-matrix journal printer fitted on


Dot-Matrix Journal Printer 10

the printer tray along with a thermal receipt printer.

The thermal receipt printer, if fitted, is configured as described in


the previous section.

Character Set Selection 10

The Dot-Matrix printer is configured using an 8-pole switch pack:


● Switch 7 selects the Character Set – OFF to select International
character set or ON to select the Arabic character set
● Switches 1 to 6 and 8 are not used.
The printer is delivered with all switches OFF (International
character set selected).

10-12 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
80-Column Printer Configuration

80-Column Printer Configuration 10

There are two types of statement printer possible in your ATM. For
each type, there is a standard variant and a parallel port (or “open”)
variant. The two types of printer can be differentiated by the
appearance of the front transport: type 1 has a cover over the
transport rollers, and type 2 has an open transport, as shown in the
following illustration.
There are some differences in the operating instructions between the
two types of printer. Refer to the appropriate type in the following
sections for the instructions specific to your printer.

Type 1 Type 2

Type 1 Printer 10

The type 1 printer leaves the factory with the paper width set to
216 mm (8.5 in.) and the paper length set to 305 mm (12 in.).
To change these settings, the paper guides in the hopper can be
adjusted for width and length, and the DIP switch settings can be
changed for width. These tasks must be performed by a customer
engineer.

Note: There is no need to adjust the switch settings on a Parallel


Port or “Open” variant of the statement printer.

Type 2 Printer 10

The type 2 printer leaves the factory with the paper width set to
216 mm (8.5 in.) and the paper length set to 102 mm (4 in.).
To change these settings, the paper guides in the hopper can be
adjusted for width or length, the DIP switch settings can be changed
for width and a jumper on the board can be adjusted for length.
These tasks must be performed by a customer engineer.

Note: There is no need to adjust the switch settings on a Parallel


Port or “Open” variant of the statement printer.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-13
Configuring the ATM
80-Column Printer Configuration

You need to adjust the DIP switch settings on the main pcb (switch
Adjusting DIP Switch pack U63 on type 1 printers and pack U50 on type 2 printers) to fit
Settings 10
the width of paper to be used on it. The following table provides the
appropriate width settings for various sizes of paper (the default
width setting is 216 mm (8.5 in.)). When choosing a width setting,
select the nearest width up from your paper size. For example,
choose the 148 mm (5.82 in.) setting for paper width of 147.5 mm
(5.81 in.).

Note: 1 = On, 0 = Off, x = Don’t care.

Paper Width Switch Setting

mm Inches 8 7 6 5 4 3 2 1

216 8.50 x 0 0 0 0 0 0 0

215 8.47 x 0 0 0 0 0 0 1

214 8.41 x 0 0 0 0 0 1 0

212 8.34 x 0 0 0 0 0 1 1

210 8.28 x 0 0 0 0 1 0 0

209 8.21 x 0 0 0 0 1 0 1

207 8.14 x 0 0 0 0 1 1 0

205 8.08 x 0 0 0 0 1 1 1

203 8.01 x 0 0 0 1 0 0 0

202 7.94 x 0 0 0 1 0 0 1

200 7.88 x 0 0 0 1 0 1 0

198 7.81 x 0 0 0 1 0 1 1

197 7.74 x 0 0 0 1 1 0 0

195 7.68 x 0 0 0 1 1 0 1

193 7.61 x 0 0 0 1 1 1 0

192 7.55 x 0 0 0 1 1 1 1

190 7.48 x 0 0 1 0 0 0 0

188 7.41 x 0 0 1 0 0 0 1

187 7.35 x 0 0 1 0 0 1 0

185 7.28 x 0 0 1 0 0 1 1

183 7.21 x 0 0 1 0 1 0 0

182 7.15 x 0 0 1 0 1 0 1

10-14 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
80-Column Printer Configuration

Paper Width Switch Setting

mm Inches 8 7 6 5 4 3 2 1

180 7.08 x 0 0 1 0 1 1 0

178 7.01 x 0 0 1 0 1 1 1

176 6.95 x 0 0 1 1 0 0 0

175 6.88 x 0 0 1 1 0 0 1

173 6.81 x 0 0 1 1 0 1 0

171 6.75 x 0 0 1 1 0 1 1

170 6.68 x 0 0 1 1 1 0 0

168 6.62 x 0 0 1 1 1 0 1

166 6.55 x 0 0 1 1 1 1 0

165 6.48 x 0 0 1 1 1 1 1

163 6.42 x 0 1 0 0 0 0 0

161 6.35 x 0 1 0 0 0 0 1

160 6.28 x 0 1 0 0 0 1 0

158 6.22 x 0 1 0 0 0 1 1

156 6.15 x 0 1 0 0 1 0 0

155 6.08 x 0 1 0 0 1 0 1

153 6.02 x 0 1 0 0 1 1 0

151 5.95 x 0 1 0 0 1 1 1

149 5.89 x 0 1 0 1 0 0 0

148 5.82 x 0 1 0 1 0 0 1

146 5.75 x 0 1 0 1 0 1 0

144 5.69 x 0 1 0 1 0 1 1

143 5.62 x 0 1 0 1 1 0 0

141 5.55 x 0 1 0 1 1 0 1

139 5.49 x 0 1 0 1 1 1 0

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-15
Configuring the ATM
80-Column Printer Configuration

To configure the type 2 printer for long paper length (more than
Adjusting Jumper JP1 254mm (10 in.)), the jumper JP1 on the interface board can be set to
(Type 2 Printer only) 10
enable the front transport shutter to operate. Set the jumper at pins 2
and 3 to enable the shutter for long paper. Set the jumper at pins 1
and 2 to disable the shutter.

The illustrations in this section show the type 1 printer, however the
Adjusting Hopper Paper instructions are identical for both types of printer.
Guides 10

To adjust the paper guides in the hopper:


1 Open the top-box of your ATM.

2 If your ATM does not have the auto-supervisor function, press


the switch on the operator panel to the supervisor position.

3 Pull and hold the latch stud upwards and push the operator
interface to the left until it reaches its second stop position.

Note: If your ATM is the short sleeve version, the operator panel
will raise automatically when the top-box is opened.

10-16 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
80-Column Printer Configuration

4 Press the green latch and pull the printer out of the ATM until
its slides are fully extended.

5 Lift the latch at the side of the hopper and slide the hopper out.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-17
Configuring the ATM
80-Column Printer Configuration

6 To change the hopper width, slide one of the paper guides to the
left or the right in its slot. This automatically moves the facing
guide an equal distance in the opposite direction. Adjust the
space between the guides to the required width.

Note: The guides are centrally located so any adjustment


automatically centres paper placement in the hopper.

7 To change the hopper length, loosen the thumbscrew on the


underside of the hopper, and move the rear guide backward or
forward in its slot to fit the required length.

8 Place the paper stack in the hopper. The paper stack must be
high enough to flatten the paper low sensor.

10-18 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
80-Column Printer Configuration

Note: Place the paper in the tray so that the black dot faces
upwards and will be on the underside and towards the top edge
of the form as it feeds into the printer.

9 Adjust the guides in the hopper to fit the paper stack, and
tighten the thumbscrew on the underside of the hopper.

10 Slide the hopper forwards to its operating position.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-19
Configuring the ATM
80-Column Printer Configuration

11 Loosen the thumbscrew which secures the top paper guides and
then slide the guides apart.

12 Place the paper between the guides. Move either guide towards
the edge of the paper. This will cause the other guide to move
the same corresponding distance. Ensure that there is 0.5 mm
(0.02 in.) clearance at each side of the paper.

13 Tighten the thumbscrew.

10-20 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
80-Column Printer Configuration

14 Hold the paper in place between the guides and press the paper
feed switch. The paper should feed through the printer.

Type 1 10

Type 2 10

15 Remove the statement from the printer transport.

16 Push the printer back into the ATM until it clicks into place.

17 If your ATM is the standard sleeve version, return the operator


panel to its home position.

Caution: If the operator panel is not returned to its home position, closing the
top-box may damage the paintwork on the front of the panel.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-21
Configuring the ATM
80-Column Printer Configuration

18 Press the switch on the operator panel to the NORMAL position.

19 Close and lock the top-box.

You may need to change the contrast control to improve print


Adjusting the Contrast 10

clarity. This can be done by adjusting the contrast control switch or,
if the printer does not have a contrast control switch, by using the
User Switches on the printer control board (switch pack U64 on an
SDC printer and U51 on a parallel printer). User Switch settings
should only be changed by an Installation Engineer.

Contrast Control Switch 10

The contrast control switch (located on the paper guide assembly)


allows you to adjust the printer contrast.
The location of the contrast control switch is shown below:
Type 1

Light

Normal

Dark

Type 2

Light

Normal

Dark

10-22 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
80-Column Printer Configuration

For both types of printer, to darken the image set the switch to the
Down position. The contrast is increased by applying more heat to
the paper, however, if the image is too dark, the print may blur
slightly.
To lighten the image set the contrast switch to the Up position. If the
contrast is too light, the print image may fade over time.
Note that the ATM must be re-started for the new contrast settings
to take effect.

User Switches (U64) 10

Note: The following procedure should only be carried out by a


qualified Installation Engineer, if the printer does not have a
contrast control switch.

To access the control board, remove the safety cover. Reset SW1 and
SW2 on User Switches (U64 on SDC, U51 on parallel printers) as
follows:

SW1 SW2

LIGHT 0 1

MEDIUM 0 0 factory setting

DARK 1 0

Note: 0 = off, 1 = ON.

The default setting for all paper (unless specified otherwise) is


MEDIUM. If the media specifications state that any grade of paper
requires increased contrast setting, then use the DARK setting.

Note: The image can be lightened or darkened by adjusting SW1


and SW2. To darken the image, the contrast must be increased
(more heat is applied to the paper). However, if the contrast is too
dark, this can cause the end image to blur slightly. If the contrast is
too light, this can cause the end image to fade over time.

Prior to the ATM’s dispatch from the factory, the statement capture
Capture Bin Threshold 10

bin threshold is configured to a setting of 10 (or 6 for buncher).


Details on how to change these thresholds can be found in the NCR
publication, Self-Service Support, System Application User Guide,
(B006-6167) or Supervisor Functions, (B006-4718) depending on your
system software.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-23
Configuring the ATM
Envelope Dispenser

Envelope Dispenser 10

To cut the dispenser bin’s plastic spacers to the correct size, proceed
as follows. The configured spacer length will accommodate your
specific envelope length.

Note: The bin is shipped with spacers which have been configured
for a standard envelope. If required, two extra spacers are shipped,
taped to the side of the dispenser bin, for you to configure to your
specific envelope size.

1 Open the top-box of the ATM.

2 If your ATM does not have the auto-supervisor function, press


the switch on the operator panel to the supervisor position.

3 Open the security enclosure.

4 Press the green latch and using the green handle, pull the
envelope depository/dispenser out of the ATM until its slides
are fully extended.

10-24 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
Envelope Dispenser

5 Slide the envelope depository bin out of the ATM.

Note: Refer to the publication 5886 ATM Operator Manual,


(B006-6194) for the procedure on removing the depository bin.

6 Lift the green latch, on either side of the envelope dispenser, and
remove the cassette using the strap handle on the front.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-25
Configuring the ATM
Envelope Dispenser

7 To open the cassette, pull out the plunger and open the door.

10-26 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
Envelope Dispenser

8 To remove the spacers from between the cassette door and the
envelope rail, remove eight screws as shown below.

Envelope Rail

Spacer

Cassette Door

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-27
Configuring the ATM
Envelope Dispenser

With the full ten segment’s fitted, the envelope space is suited to the
Adjusting the Spacer minimum length of envelope, 203 mm (8.00 in.).
Length 10

10 10
Cut Here
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2
1 1

Each spacer segment removed, increases the space by


5 mm (0.20 in.). With all ten segments removed, the maximum
length of envelope, (254 mm (10.00 in.)) can be loaded into the
cassette.
Segments should be removed from the spacers so that your
envelopes fit into the cassette with 1 or 2 mm to spare (but no more
than 5 mm (1 segment)).
The spacers can be cut with a stanley knife or small steel saw.
Remove any burrs left on the legs of the spacers with a smooth file.

10-28 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Configuring the ATM
Envelope Dispenser

The table below tells you where to make the cut for the measured
length of envelope.

Measured Length of Envelope

Millimetres Inches Cut above Segment Number:

203 - 207 8.00 - 8.15 Do not cut

208 - 213 8.19 - 8.38 9

214 - 218 8.42 - 8.58 8

219 - 223 8.62 - 8.78 7

224 - 228 8.82 - 8.97 6

229 - 233 9.01 - 9.17 5

234 - 238 9.21 - 9.37 4

239 - 243 9.41 - 9.57 3

244 - 248 9.60 - 9.76 2

249 - 253 9.80 - 9.96 1

254 10 Cut off segment 1

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 10-29
Configuring the ATM
Envelope Dispenser

10-30 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Fitting Decals to the ATM

Chapter 11
Fitting Decals to the ATM

Fitting the Decals 11-1


Advert Light 11-1
Card Orientation Window and Clear Window 11-1
Entry/Exit Decals 11-2
Card Acceptance Decal 11-2

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Fitting Decals to the ATM

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Fitting Decals to the ATM 11

Fitting the Decals

Fitting the Decals 11

This chapter describes how to fit decals to the front of the ATM.
Specifications for the decals can be found in Chapter 4.

Advert Light

Receipt Exit

Statement Exit
Card Reader
(Motorised/Dip)

Cash Exit/Deposit Entry/ Cash Exit/Deposit Entry


Cheque Entry Cash Deposit

Cash Deposit

Decals are fitted to the facia of the 5886 Drive-Up ATMs as follows:

Fix the decal to the surface of the advert light panel (inside or out
Advert Light 11

depending on the decal design) before fitting the advert light and
collar. Make sure that the panel is clean and dry before applying the
decal.

To fit a decal behind the card orientation plastic window or the


Card Orientation Window larger clear window (fitted if an envelope depository is not
and Clear Window 11
configured), proceed as follows:
1 Insert the two window extraction tools (supplied with the ATM)
into the holes at the base of the window.

2 Push down on the two extraction tools to release the window’s


catches, then pull the window out from the facia.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation 11-1
Fitting Decals to the ATM
Fitting the Decals

3 Place the decal in position and then press the plastic window
back into the facia.

The facia of the ATM has been provided with recesses for self-
Entry/Exit Decals 11

adhesive decals to identify the entry and exit slots. Make sure that
the surface is clean and dry and then apply the correct decal firmly.

Position this decal onto the side panel at the right hand side of the
Card Acceptance Decal 11

facia. Make sure that the surface is clean and dry and then apply the
decal firmly.

11-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Table of Contents
Transient and Power Protection

Appendix A
Transient and Power Protection

AC Power Line Transient Protection A-1

Data Line Transient Protection A-3

NCR Power Protection and Cabling Products A-4


AC Power Line Transient Protection A-4
Data Line Transient Protection A-5
Uninterruptible Power Supplies A-5
Contact Information A-7

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Table of Contents
Transient and Power Protection

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation


Transient and Power Protection
A

AC Power Line Transient Protection

AC Power Line Transient Protection A

In the process of power distribution, transient electrical energy


(including, but not limited to, lightning strikes, intermittent short
circuits, and switching transients) can be introduced on to power
lines. Such transient energy can be very damaging to electronic
hardware and can also cause data corruption. Under these
circumstances, NCR recommends the use of ac power transient
suppressors and data (communication) line transient suppressors.
Such protective devices are intended to guard against power and
data line transients that can result in hardware damage and various
system or program errors.
Improvement of any deficiencies in power quality is a customer
responsibility. Malfunction and/or component failure as a result of
power quality problems are/is not covered by NCR Maintenance
Agreement, NCR accepts no liability for any such occurrence nor for
its consequences.
When power transient suppression is required, the suppressors
used should meet the following minimum requirements:
● Dissipate energy to match the appropriate application categories
as defined by IEEE Standard 587. These categories are described
in the table below:

Comparable
Location
to IEC
Category Transient
No 664
Category

Waveform Amplitudes

A=Outlets > II 0.5 µ s Risetime, 6 kV


10 m (30 ft) then 100 kHz
from Cat. B Ringwave, each 200A
A= Outlets > peak=60% of
20 m (60 ft) previous
from Cat. C

B=Major III Volts=1.3 x 5 µ s 6kV


feeders, Current= 8 x 20 µ s 3kA
short branch and
circuits, and 0.5 µ s Rise = 100 6kV
load centres kHz Ringwave 500A

C = Service IV Volts = 1.2 x 5 µ s 10kV or more


Entrance and
run to load Current = 8 x 20 µ s 10kA or more
centre

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-1
Transient and Power Protection
AC Power Line Transient Protection

● Be of the voltage limiting (clipping), or tracking filter type. The


suppressor must not ‘clamp’ the voltage to zero, and must self-
recover after passage of the transient. The suppressor may be of
the hybrid type construction that makes use of various
technologies in order to meet speed and dissipation
requirements.
● Exhibit a ‘short circuit’ mode upon its failure, thus providing a
positive indication of its failure such as a blown fuse or tripped
breaker
● Be listed by the accepted safety organization for the country
involved (e.g. UL, CSA, VDE, ETL, etc.) and the installation
must conform to local, state, and national electrical codes and
regulations.

A-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Transient and Power Protection
Data Line Transient Protection

Data Line Transient Protection A

The nature of the transient phenomenon may extend to the data


communication lines connected to this equipment. It is the
responsibility of the customer to install and connect a data line
transient suppression system to correct or prevent any deficiencies.
Such systems must meet the following minimum requirements:
● Be of the voltage limiting type and must self-recover after
passage of the transient
● Exhibit a ‘short circuit’ mode upon its failure to insure a positive
indication of its failure
● Insert less than 5 ohms resistance and minimal inductive and
capacitive loading at the operating frequency, in each data line
in order to avoid signal degradation
● Be installed in accordance with all applicable local, state, and
national electrical codes and regulations.

Note: In certain countries, NCR is able to supply both power and


data line transient suppressors as well as a comprehensive line of
power conditioning equipment. For application data, contact your
NCR Customer Services Division Representative.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-3
Transient and Power Protection
NCR Power Protection and Cabling Products

NCR Power Protection and Cabling


Products A

Power protection equipment suitable for use with NCR ATMs can
be purchased from the NCR Power Protection and Cabling group.
Some of these products are outlined below.

The following products can be purchased from the NCR Power


AC Power Line Transient Protection and Cabling group to help provide protection from
Protection A
power line spikes and surges:

NCR Product ID Description

4060-4030-0094 110V, 3 outlet, wall plug-in, 15 Amp


suppressor, United States applications

4060-4050-0094 110V, 3 outlet, strip, 15 Amp


suppressor with 1.8 metres (6 feet) of
power cable, United States applications

4060-4070-0094 110V, 7 outlet, strip, 15 Amp


suppressor with 1.8 metres (6 feet) of
power cable, United States applications

4060-4310-7594 220V, 4 outlet, strip, United Kingdom


plug fitted

4060-4311-7594 220V, 4 outlet, strip,


German/European plug fitted

4060-4312-7594 220V, 4 outlet, strip, French plug fitted

These products have numerous features:


● unique five-stage hybrid circuitry
● offers protection from spikes and surges
● protection covers all modes - line to neutral, line to earth
(ground) and neutral to earth (ground)
● integral RF/EMI damping capability
● thermal overload protection
● high capacity fusing
● indicator lights display operational readiness
● plastic housing is highly flame retardant, conforming to UL94-
5V.

A-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Transient and Power Protection
NCR Power Protection and Cabling Products

The following Data Line Transient Voltage Surge Suppressors can


Data Line Transient be purchased from the NCR Power Protection and Cabling group to
Protection A
help protect the communications port against harmful transient
surges from both external and internal sources not eliminated by
Uninterruptible Power Supplies or other AC protection:

NCR Product ID Description

4060-K018-V000 25 pin, CMP, snaps in to United States


surge suppressors

4060-K019-V000 25 pin, CFP, snaps in to United States


surge suppressors

4060-K021-V000 25 pin, CMP, stand-alone, all


applications

4060-K022-V000 25 pin, CFP, stand-alone, all


applications

Note: The first two products are designed to snap-in to the interface
port on NCR Series 4000 Transient Voltage Surge Suppressors in the
United States. The second two products are designed to be stand-
alone for use in Europe.

Uninterruptible Power Supplies (UPS) can be purchased from the


Uninterruptible Power NCR Power Protection and Cabling group to help protect
Supplies A
information and equipment by providing power conditioning and
battery back-up.

NCR Product ID Description

4084-1000-7194 1000 VA on-line UPS with rack/tower


configuration, 120VAC 50/60 Hz

4084-1000-7494 1000 VA on-line UPS with rack/tower


configuration, 230VAC 50/60 Hz

These products offer:


● on-line topology
● 10 minute battery backup at full load
● true sine wave output
● 100% clean, conditioned power to connected equipment
● extended battery cabinets available for extended run times
● on-board SNMP optional on all models
● standard LAN/serial (RS-232) network interface
● standard rack-mountable unit design
● also available in 1500 VA, 2100 VA and 3000 VA sizes.

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-5
Transient and Power Protection
NCR Power Protection and Cabling Products

NCR Product ID Description

4071-1000-7194 1000 VA Enhanced line-interactive


UPS, 120VAC 60 Hz

4071-1001-7194 1000 VA Enhanced line-interactive


UPS, 120VAC 60 Hz, Rack-mountable

4071-1000-7494 1000 V A Enhanced line-interactive


UPS, 230 VAC, 50/60 Hz

4071-1001-7494 1000 V A Enhanced line-interactive


UPS, 230 VAC, 50/60 Hz,
Rack-mountable

These products offer:


● line-interactive topology
● 8 minute battery backup at full load
● true sine wave output
● input voltage selectable to 110/127 VAC or
220/240 VAC
● advanced battery management prolongs battery life and ensures
quick availability after discharge
● advanced battery management for early failure detection and
advanced user warning
● internal transformer provides voltage buck/boost
● standard LAN/serial (RS-232) network interface
● available in rack-mountable configuration
● also available in 600VA, 1500VA, 2000VA, 2200VA sizes.

NCR Product ID Description

4070-1000-7194 1000 VA Line-interactive UPS,


120AC, 60 Hz

4071-1000-7494 1000 VA Line-interactive UPS,


230VAC, 50/60 Hz

These products offer:


● line-interactive topology
● 7 minute battery backup at full load
● modified sine wave output
● input voltage selectable at 110/127 VAC or
220/240 VAC

A-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Transient and Power Protection
NCR Power Protection and Cabling Products

● advanced battery management prolongs battery like and


ensures quick availability after discharge
● advanced battery management for early failure detection and
advanced user warning
● internal transformer provides voltage buck/boost
● standard LAN/serial (RS-232) network interface
● hot-swappable batteries
● also available in 450 VA, 700 VA, 1500 VA sizes.

For more information from NCR’s Power Protection and Cabling


Contact Information A

Group on the power protection, data line transient suppressors and


uninterruptible power supply products available, warranty or
configuration assistance, call the appropriate number below:

Telephone

Worldwide (excl. USA) +1 919 460 9489

USA only 1 800 257 0458

Facsimile

Worldwide +1 919 460 9653 or


+1 919 460 8976

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation A-7
Transient and Power Protection
NCR Power Protection and Cabling Products

A-8 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Index

Index 0

40-Column Printer Configuration 10-7


Numerics 80-Column Printer Configuration 10-13

AC Power Line Transient Protection A-1


A AC Power Requirements 2-1
Adjustable Plinth 1-40
Air Flow 3-4
Alarm Interface Cable 2-11
Ambient Lighting 1-12
Anchor Bolts 1-42
ATM Installed Directly on to the Floor 1-40

Barometric Pressure Limits 3-2


B
Cables
C High Order Communications Cable 2-4
Power Cable 2-2
Remote Device Cables 2-6
Combination locks
Customer setting combination 7-10
Communications Configuration 10-4
Communications Requirements 2-4
Concrete Plinth 1-40
Configuring the ATM
40-Column Printer 10-7
80-Column Printer 10-13
Communications
S4I 10-4
Self-Service Support 10-4
Currency Cassette 10-2
Currency Dispenser 10-5
Device 10-3
Envelope Dispenser 10-24
Connecting Cables
All Other Cables 9-21
Power Cable 9-18
Connecting Cables to the ATM 9-18
Controlled Access Electronic Lock 7-15
Currency Cassette Configuration 10-2
Currency Dispenser Configuration 10-5
Customer Responsibilities xv
Customer Setting Combination 7-7

Data Line Transient Protection A-3


D Decal Dimensions
Advert Light 4-4

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Index-1
Index

Card Orientation Window 4-2


Clear Window 4-3
Entry/Exit Slot Decals 4-5
Decal Specifications 4-1
Device Configuration 10-3
Dimensions
Ambient Lighting 1-12
Heights to Main Facia Items 1-11
Severe Environment Fitted 1-9
Short Sleeve Before Collar has Been Fitted 1-6
Standard Collar 1-7
Standard Collar With Advert Light 1-8
Standard Sleeve Before Collar has Been Fitted 1-5

Electromagnetic Compatibility (EMC) and Safety 3-4


E Electronic Lock
Emergency Opening Procedure 7-14
Not Working 7-13
EMI Emmision 2-3
EMI Susceptibility 2-3
Envelope Dispenser Configuration 10-24

Factory Setting 7-7


F Fitting a Third Party Video Camera 1-45
Fitting an Infill Panel 8-28
Fitting the Cheque Acceptor Bin 8-22
Fitting the Collar
Standard Collar With Advert Light 8-36
Standard Collar With Facia Light 8-31
Fitting the Decals 11-1
Fitting the Severe Environment Parts 8-2
Floor Covering 1-42
Floor Loading 1-42

Grounding Requirements 2-2


G
Heat Dissipation 3-4
H Heights to Main Facia Items 1-11
High Order Communications Cable, Standard Cable (RS-232) 2-5
Hole in the Wall
Installation Categories 1-29
Installing Through a Glass Wall 1-29
Installing Through a New Hole 1-34
Replacing 5088 With Modifications to Hole in Wall 1-30
Replacing Personas 5688 With No Modifications to Hole in Wall 1-32
Sealing 1-36
How to Change the Combination Lock 7-8
How to Lock the Combination Lock 7-8
How to Operate the Silent Alarm 7-8

Index-2 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Index

Infill Panel Dimensions


I Infill Panel (5088) 1-43
Infill Panel (5688) 1-44
Input Voltage Setting 2-1
Inspecting the ATM for Damage 7-1
Installation Accessories 5-1
Installation And Service Clearances
Minimum Clearances 1-17
Recommended Clearances 1-13
Installation and Service Clearances
Exterior Wall
Standard Collar 1-26
Standard Collar With Advert Light 1-27
Installation Planning Check List 5-2
Installation Procedure 6-1
Installation Report Form 7-2
Installing a Video Camera 1-45
Installing Through a New Hole 1-34
Internal Packaging, Removing 9-1

Locking
L Locking a Sub-lock 7-23
Locks
Controlled Access Electronic Lock 7-15
Controlled Access Electronic lock With a Sub-lock 7-18
Controlled Access Electronic lock Without a Sub-lock 7-16
Electronic Lock 7-12
Unlocking and Locking a Security Enclosure with a Controlled Access
Electronic Lock 7-15

Mandatory Modifications to Plinth or Floor


M Adjustable Plinth 1-40
ATM Installed Directly on to the Floor 1-40
Concrete Plinth 1-40
Floor Loading 1-42
Manoeuvring the ATM into Position 1-2
Module Locations 9-2

Opening and Closing an Electronic Lock 7-12


O Overview -xiv

Package Dimensions 1-1


P Planning Check List 5-2
Plinth
Installation Required 1-38
Positioning the ATM 8-27
Power Cable 2-2
Power Consumption 2-1
Product Identification xvi

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Index-3
Index

Remote Device Cables


R Alarm Interface Cable 2-11
Remote Relay Cable 2-14
Remote Status Monitor 2-9
RS-232 Cable 2-6
Remote Status Indicator 2-7
Removing the External Packaging 7-1
Removing the Internal Packaging 9-1
Replacing 5088 With Modifications to Hole in Wall 1-30
Replacing Personas 5688 With No Modifications to Hole in Wall 1-32
Requirements for the Floor
Installation Without Infill Panel Required 1-38
Support Plinth 1-37

Sealing the Collar and Bolting the ATM to the Plinth 8-44
S Sealing the Hole in the Wall 1-36
Security Bolts 1-42
Security enclosure
Combination lock and keylock 7-8
Combination locks 7-6
Customer setting combination 7-10
keylocks 7-6
Service Access Panels 1-28
Service Clearances
Exterior Wall
Standard Collar 1-26
Standard Collar With Advert Light 1-27
Minimum Clearances 1-17
Recommended Clearances 1-13
Silent Alarm 7-13
Standard Collar With Advert Light 1-26
Standard Security Enclosure 7-5
Sub-lock
Locking 7-23
Unlocking 7-22
Support Plinth 1-37

Temperature and Humidity 3-1


T Temperature Rise 3-4
Terminal Dimensions 1-4
Heights to Main Facia Items 1-11
Severe Environment Fitted 1-9
Short Sleeve Before Collar has Been Fitted 1-6
Standard Collar 1-7
Standard Collar With Advert Light 1-8
Standard Sleeve Before Collar has Been Fitted 1-5
Transient Power Loss 2-3
Transient Protection A-1

Unlock 7-5
U Unlocking

Index-4 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
Index

Unlocking a Sub-lock 7-22


Unlocking and Locking a Security Enclosure with a Controlled Access
Electronic Lock 7-15
Unlocking and Locking the Standard Security Enclosure 7-5

Video Camera 1-45


V

NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Index-5
Index

Index-6 NCR Personas M Series 5886 Drive-Up Site Preparation and Installation
User Feedback Form

Title: NCR Personas M Series 5886 Drive-Up Site Preparation and Installation Manual
Number: B006-6328-F000 Date: 1204

NCR welcomes your feedback on this publication. Your comments can be of great value in helping us
improve our information products.
Cut

You may send your comments to us electronically. See over for details.

Circle the numbers below that best represent your opinion of this publication.

Ease of use 5 4 3 2 1 0 5 = Excellent


4 = Good
Accuracy 5 4 3 2 1 0
3 = Adequate
Clarity 5 4 3 2 1 0 2 = Fair
1 = Poor
Completeness 5 4 3 2 1 0
Organization 5 4 3 2 1 0 0 = Not applicable
Appearance 5 4 3 2 1 0
Examples 5 4 3 2 1 0
Illustrations 5 4 3 2 1 0
Job performance 5 4 3 2 1 0
Question resolution 5 4 3 2 1 0
Overall satisfaction 5 4 3 2 1 0

Indicate the ways you feel we could improve this publication.

❑ Improve the table of contents ❑ Add more/better quick reference aids


❑ Improve the overview/introduction ❑ Add more examples
❑ Improve the organization ❑ Add more illustrations
❑ Improve the index ❑ Add more step-by-step procedures
❑ Make it less technical ❑ Add more troubleshooting information
❑ Make it more concise/brief ❑ Add more detail
Write any additional comments you may have below and on additional sheets, if necessary. Include page
numbers where applicable.

Use the following addresses to send your comments to us electronically:


e-mail - userfeedback@exchange.scotland.ncr.com

Cut
Fold

If we may contact you concerning your comments, please fill in the information below:

Name:
Organization:
Company:
Address:

Phone: Fax:

Thank you for your evaluation of this publication. Fold the form where indicated, tape (please do not staple),
and drop in the mail.

F 8763-0695

Fold

Affix
Postage
Stamp
Here

NCR Financial Solutions Group Ltd.


Information Solutions Feedback
Kingsway West
Dundee
Scotland
DD2 3XX

S-ar putea să vă placă și