Sunteți pe pagina 1din 12

Cuprins

1. TEMA DE PROIECTARE .............................................................................................................. 2


A. ECUAȚIA DE BILANȚ.............................................................................................................. 2
B. CALCULUL DIAMETRULUI INTERIOR AL MANTALEI ................................................... 4
C. CALCULAREA VITEZEI AGENTULUI PRIMAR (W₁) ......................................................... 4
1. Calculul W₁(fără șicane) .......................................................................................................... 4
D. CALCULUL DEFINITIV AL SCHIMBĂTORULUI DE CĂLDURĂ ..................................... 5
E. CALCULUL GROSIMII IZOLAȚIEI ........................................................................................ 7
2. DIMENSIONAREA POMPELOR DE CIRCULAȚIE PENTRU CEI DOI AGENȚI ................... 8
A. DIMENSIONAREA RACORDURILOR ................................................................................... 8
B. DIMENSIONAREA POMPEI .................................................................................................... 9
1. AGENTUL SECUNDAR............................................................................................................. 10
2. AGENTUL PRIMAR ................................................................................................................. 11
3. DESENUL ........................................................................................................................................ 12

1
1. TEMA DE PROIECTARE

Să se proiecteze un schimbător de căldură multitubular având cunoscute


următoarele date de proiectare:
N=8

Q=300+4*N =332 KW

t₁'=95+N=103 ᵒC

t₁''=85 ᵒC

t₂'=10 ᵒC

t₂''=45 ᵒC

Q-sarcina termică a schimbătorului de căldură;

t₁'-temperatura de intrare a agentului primar;

t₁''-temperatura de ieșire a agentului primar;

t₂'-temperatura de intrare a agentului secundar

t₂''-temperatura de ieșire a agentului secundar.

A. ECUAȚIA DE BILANȚ

Q=η*G₁*Cp₁(t₁'-t₁'')=G₂*Cp₂(t₂'-t₂'')=K*Su*Δtm,log

G₁,G₂- debite masice de agent

Cp₁,Cp₂-călduri specifice

Cp₁=Cp₂=4,186 Kj/Kg*K

η'iz=0,98÷0,99

K-coeficient global de transfer de căldură

1
K= 1 𝜎 1 [W/m²*K]
𝛼𝑖
+𝛴 𝜆 +𝛼𝑒

K'=800÷1200 W/m²*K
𝑄 332
G₁= = =4,498 Kg/s
𝜂∗𝐶𝑝₁(𝑡 ′ −𝑡 ′′) 0,98∗4186(45−10)

2
𝑄 332
G₂=𝜂∗𝐶𝑝2 ∗(𝑡 2′ −𝑡 2′′)=0,98∗4,186(45−10)=2,312 Kg/s

′ ′′
(𝑡 1 ˗𝑡 2 )−(𝑡 1′′ ˗𝑡 2′ ) 58−75
Δtm,log= 𝑡₁′˗𝑡₂′′ = 58 =66,13 K
𝑙𝑛 𝑙𝑛
𝑡₁′′˗𝑡₂′ 75

𝑄 332∗10⁵
Su= = =5,020 m²
𝐾∗𝛥𝑡𝑚,𝑙𝑜𝑔 1000∗66,13

Su-suprafața laterală a țevii

Su'=π*dm*L'sc*n'tot [m²]

L'sc=2÷5 m

ȚEAVĂ OL Ø20X2 – de=20 mm


σ=2 mm
di=16 mm
dm=18 mm

L'sc=4m

S'u=π*dm*L'sc*n'tot
𝑆𝑢 5,020
n'tot= = =22,19
𝜋∗𝑑𝑚∗𝐿′𝑠𝑐 𝜋∗0,018∗4

Pentru dimensionarea schimbatorului de căldură se utilizează ecuația de continuitate

𝐺₂ 𝜋∗𝑑𝑖²
=W₂* *n'1TR
𝜌₂ 4

ρ₂=1000 Kg/mᶟ

W₂=0,5÷1,5 m/s n'₁TR=11,49


4𝐺₂ 4∗2,312
n'1TR= = =11,49 nTR=2
𝜌2 ∗𝑊 2 ∗𝜋∗𝑑𝑖² 1000∗1∗𝜋∗0,016²
n₁TR=15
22,19
nTR= =1,931
11,49 nTOT=30

4𝐺₂ 4∗2,312
W₂= = =0,7665 m/s
𝑛1 𝑇𝑅∗𝜌2 ∗𝜋∗𝑑𝑖² 15∗10000∗𝜋∗0,016²

W₂-viteza agentului secundar

3
B. CALCULUL DIAMETRULUI INTERIOR AL MANTALEI

Dim=(ndiag-1)*s+de+2Kₒ

Kₒ-joc inelar

s=de+(8÷12)mm

Kₒ=6÷10mm

s=20+10=30 mm

Kₒ=8 mm

Dim=(7-1)*30+20+(2*8)=216 mm

Dim=Dem-2σm

Dem=245 mm

σ=14 mm

Dim=245-(2*14)=217 mm

217=(7-1)*30+20+2*Kₒ

Kₒ=8,5 mm

C. CALCULAREA VITEZEI AGENTULUI PRIMAR (W₁)

1. Calculul W₁(fără șicane)


𝜋∗𝐷𝑖𝑚² 𝜋∗𝑑𝑒²
S₁= − 𝑛𝑡𝑜𝑡 ∗ =0,027 m²
4 4

𝐺₁ 4,498
W₁= 𝜋∗𝐷𝑖𝑚2 𝜋∗𝑑𝑒²
= 𝜋∗0,2162 𝜋∗0,020²
𝜌1 ∗ −𝑛𝑡𝑜𝑡∗ 1000∗ −30∗
4 4 4 4

W₁=0,113 m/s

Deoarece viteza W₁ este sub limita inferioară de 0,5 m/s se vor monta șicane la distanța
l=200 mm una de alta.

S₁trans=[(Dim-n₁dig*de)*lsic] [m²]

lsic=0.2 m

S₁trans=(0.216-7*0.020)*0.2=0.0152

4
𝐺₁
W₁tr=
𝜌1 ∗[(𝐷𝑖𝑚−𝑛1 𝑑𝑖𝑎𝑔)∗𝑙𝑠𝑖𝑐]

4.498
W₁tr= =0.295 m/s
1000∗0.0152

D. CALCULUL DEFINITIV AL SCHIMBĂTORULUI DE CĂLDURĂ

Calculul de finitv presupune determinarea coeficientului global de transfer de căldură


1
K= 1 𝜎𝑖 1 [W/m²*K]
+𝛴 +
𝛼₁ 𝜆𝑖 𝛼₂

Nu₂=0.0209*𝑅𝑒₂0.8 ∗ 𝑃𝑟₂0.45

Nu₁=C*ε₁*ε₂*𝑅𝑒₁𝑚 ∗ 𝑃𝑟₁0.38

C - 0.59 →Re∈8÷1000

-0.21 →Re∈1000÷20000

m – 0.47 → Re∈8÷1000

-0.62→ Re∈1000÷20000

ε₁=1.3 – este o corecție ce ține cont de tipul de așezare al țevilor

ε₂=0,6 – corecție care ține seama de faptul că circulația este transversală pe fasciculul de țevi

PENTRU α₁

Lc=20 mm
𝑡 1′ +𝑡₁′′ 103+85
t₁m= = =94 °C
2 2

t λ
90 0,6804
94 λ₁
100 0,6827
λ₁=0,68132 W/*K

5
t Pr ν
90 1,95 0,326*10−6
94 Pr₁ ν₁
100 1,75 0,295*1010−6
Pr₁=1,87

ν₁=0,313*10−6 m²/s
𝑊1𝑡𝑟 ∗𝑑𝑒 0,295∗0,020
Re₁= = 0,313∗10−6 =18849,8
𝜈₁

C₁=0,21

m=0,62

ε₁=1,3

ε₂=0,6

Nu₁=C*ε₁*ε₂*𝑅𝑒₁𝑚 ∗ 𝑃𝑟₁0.38=0,21*1,3*0,6*18849,80,62*1,870,38

Nu₁=92,959

𝑁𝑢1 ∗𝜆₁ 92,959∗0,68132


α₁= =
𝑑𝑒 0,020

α₁=3166,7 W/m²*K

Pentru α₂

lc=16 mm

t₂m=27,5 °C

t₂ λ Pr ν

20 0,5989 7 1*10−6

27,5 λ₂ Pr₂ ν₂

30 0,6176 5,4 0,805*10−6

λ₂=0,6129 W/m*K

Pr₂=6

ν₂=0,854*10−6
𝑊2𝑡𝑟 ∗𝑑𝑖 0,7665∗0,016
Re₂= = =14360,6
𝜈₂ 0,854∗10−6

Nu₂=0,0209*14360,60,8 ∗ 60,45 = 99,095

6
𝑁𝑢2 ∗𝜆₂ 990,95∗0,6129
α₂= =
𝑑𝑖 0,016

α₂=3795,9 W/m²*K
𝜎 𝜎 𝜎𝑚 𝜎𝑑
Σ = 𝑑+ +
𝜆 𝜆𝑑 𝜆𝑚 𝜆𝑑

𝜎𝑑
→2*10−5 pentru apă tratată
𝜆𝑑

0,02
2*10−5+ 50 +2*10−5 =8*10−5 W/m²*K

1 1
K= 1 𝜎𝑖 1 1 = 1 = 1516,92 W/m²*K
+𝛴 + +8∗10−5 +
𝛼₁ 𝜆𝑖 𝛼₂ 3166,7 3795,9

Q=K*S*Δtm,log
𝑄 332∗10ᶟ
S= = =3,309 m²
𝐾∗𝛥𝑡𝑚,𝑙𝑜𝑔 1516,92∗66,13

𝑆 3,309
L= =
𝜋∗𝑑𝑚∗𝑛𝑇𝑂𝑇 𝜋∗0,018∗30

L=1,95 m
E. CALCULUL GROSIMII IZOLAȚIEI

Schimbătorul multitubular se poate izola cu saltele din vată minerală având grosimea intre 2
cm și 10 cm.

Schimbătorul de căldura prezintă o pierdere semnificativă prin capace,flanșe,șuruburi pe care


sunt mai dificil de calculat,se pot aproxima.

Estimăm valoarea lui αi=15 W/m²*K

Întrucât raportul dintre diametrul izolației și diametrtul interior al mantalei are o valoare
ridicată se mai face simplificarea utilizării relațiilorla pereți plani

Qc=G₁*Cp₁*(t₁'-t₁'')=4,498*4,186*(103-85)

Qc=338,9 KW=338,9 *10ᶟ W

𝑡₁ −𝑡𝑎𝑒𝑟
Qm= 1 1 𝐷𝑒𝑚 1 𝐷𝑖𝑧 1
+ 𝑙𝑛 + 𝑙𝑛 +
𝜋∗𝐷𝑖𝑚∗𝛼1 ∗𝐿 2𝜋∗𝜆𝑜𝑙 𝐷𝑖𝑚 2𝜋∗𝜆𝑖𝑧 𝐷𝑒𝑚 𝜋∗𝐷𝑖𝑧∗𝛼𝑖𝑛𝑡 ∗𝐿

1 1
= =0,000237
𝜋∗𝐷𝑖𝑚∗𝛼 1 ∗𝐿 𝜋∗0,217∗3166,7∗1,95

7
1 𝐷𝑒𝑚 1 0,245
𝑙𝑛 = 𝑙𝑛 =0,000197
2𝜋∗𝜆𝑜𝑙 𝐷𝑖𝑚 2𝜋∗50∗1,95 0,217

1 𝐷𝑖𝑧 1 0,285
𝑙𝑛 = 𝑙𝑛 =0,0342
2𝜋∗𝜆𝑖𝑧 𝐷𝑒𝑚 2𝜋∗0,036∗1,95 0,245

Diz=Dem+2*0,02=0,245+0,04=0,285 m
1 1
= =0,0381
𝜋∗𝐷𝑖𝑧∗𝛼𝑖𝑛𝑡 ∗𝐿 𝜋∗0,285∗15∗1,95

94−10
Qm= =202,409 W
0,415

Qp=1,6*Qm=1,6*202,409=323,85 W
𝑄𝑝 323,85
η=1- =1- =0,99904
𝑄𝑐 338,9∗10ᶟ

Valoare mai mare decât randamentul ales inițial,rezultă că grosimea izolației aleasă inițial este
suficientă.

η=99,9%

2. DIMENSIONAREA POMPELOR DE CIRCULAȚIE PENTRU CEI


DOI AGENȚI

A. DIMENSIONAREA RACORDURILOR

𝐺₁ 𝜋∗𝑑𝑖²𝑟𝑎𝑐1
=W₁rac*S₁rac=W₁rac*
𝜌₁ 4
𝑑𝑖𝑟𝑎𝑐1,𝑆𝑇𝐴𝑆 76 mm
W₁rac=0,5÷1,5 m/s Diametrul 83 mm
exterior
𝐺 1 ∗4 4,498∗4
𝑑𝑖𝑟𝑎𝑐1 =√ =√ =0,0756 m Grosimea 3,5 mm
𝜌1 ∗𝑊 1 ∗𝜋 1000∗1∗𝜋
peretelui
𝑑𝑖𝑟𝑎𝑐1 =75,6 mm

𝑑𝑖𝑟𝑎𝑐1,𝑆𝑇𝐴𝑆 =76 mm
4,498∗4
𝑊₁𝑟𝑎𝑐 = =0,99 m/s
1000∗𝜋∗0,076²

8
𝐺₂ 𝜋 ∗ 𝑑𝑖²𝑟𝑎𝑐²
= 𝑊 2 𝑟𝑎𝑐 2 ∗
𝜌₂ 4

𝐺 2 ∗4 2,312∗4
𝑑𝑖𝑟𝑎𝑐₂ = √ =√ =0,054 m
𝜌2 ∗𝑊 2 ∗𝜋 1000∗1∗𝜋

𝑑𝑖𝑟𝑎𝑐 2,𝑆𝑇𝐴𝑆 =53 mm

𝑑𝑖𝑟𝑎𝑐2,𝑆𝑇𝐴𝑆 53 mm
Diametrul 60 mm
exterior
Grosimea 3,5 mm
peretelui

B. DIMENSIONAREA POMPEI

𝐺
Pompă: - V=𝜌

- Hp=Δ𝑃𝑡𝑜𝑡

Δ𝑃𝑡𝑜𝑡 =Δ𝑃𝜆 +Δ𝑃𝜉 [Pa]

Δ𝑃𝜆 - pierderi de sarcină liniare (apar în situația în care curgerea este stabilizată
și depind de lungimea conductei prin care curge apa)

Δ𝑃𝜉 - pierderi de sarcină locale (apar în toate zonele în care există o modificare
de scțiune, direcție, de curgere, obstrucție)
𝜆∗𝑙 𝜌∗𝑊²
Δ𝑃𝜆 = *
𝑑 2

𝜌∗𝑊²
Δ𝑃𝜉 =ξ*
2

λ=f(Re)

Re∈[3000÷100000] →λ=0.3164*𝑅𝑒 −1/4

Re∈[100000÷2*1000000]→λ=0.0054+0.3964*𝑅𝑒 −1/3

9
1. AGENTUL SECUNDAR

Δ𝑃𝑡𝑜𝑡2 =Δ𝑃𝜆2 +Δ𝑃𝜉2


𝜆(𝑅𝑒)∗𝐿𝑓𝑖𝑛 ∗𝑛𝑡𝑟 𝜌∗𝑊²
Δ𝑃𝜆2 = *
𝑑𝑖 2

Nr crt Tip ξ Repetări 𝜌∗𝑊² TOTAL


ξ*
2
1 Robinet 2 2 1096,2 2192,4
2 Colector 1 2 548,1 1096,2
intrare/ieșire
3 Intrare+ieșire 1 𝑛 𝑇𝑅 548,1 1096,2
țevi
4 Cot (180°) 2,5 𝑛 𝑇𝑅 -1 1370,26 1370,26
între treceri
sau secțiuni
5 Δ𝑃𝜉 =5755,06

𝑅𝑒2 =14360,6

λ=0,3164*14360,6−1/4 =0,0289

0,0289∗1,95∗2 1000∗0,7665²
Δ𝑃𝜆2 = * =2069,36 Pa
0,016 2

𝜌∗𝑊²𝑟𝑎𝑐2
Δ𝑃𝜉 =ξ*
2

4∗𝐺₂ 4∗2,312
𝑊𝑟𝑎𝑐2 = = 1,047 m/s
𝜌2 ∗𝜋∗𝑑𝑖² 𝑟𝑎𝑐2 1000∗𝜋∗0,053²

2∗1000∗1,047²
1. Δ𝑃𝜉 = =1096,2 Pa
2
1000∗1,047²
2. Δ𝑃𝜉 =1* 548,1 Pa
2

3. Δ𝑃𝜉 =548,1 Pa
1000∗1,047²
4. Δ𝑃𝜉 =2,5* =1370,26 Pa
2

Δ𝑃𝑡𝑜𝑡2 =2069,36+5755,06=7824,42 Pa

10
2. AGENTUL PRIMAR

Nr crt Tip ξ Repetări 𝜌∗𝑊² TOTAL


ξ*
2
1 Robinet 2 2 980,1 1960,2
2 Intrare în 1,5 2 735,07 1470,14
spațiul
dintre țevi
3 Circulație 3 𝑛𝑠𝑖𝑐 +1=9 1470,15 13231,35
peste
fasciculul
de țevi
așezat în
eșicher
4 Întoarcerea 1,5 𝑛𝑠𝑖𝑐 =8 735,07 11761,2
(de 180°)
pe langă un
perete
desparțitor
în spațiul
dintre țevi
5 Δ𝑃𝜉 =28422,89

𝜌∗𝑊²𝑟𝑎𝑐1 1000∗0,99²
Δ𝑃𝜉1 = ξ* =2* =980,1 Pa
2 2

1000∗0,99²
Δ𝑃𝜉1 =1,5* =735,07 Pa
2

1000∗0,99²
Δ𝑃𝜉1 =3* =1470,15 Pa
2

1000∗0,99²
Δ𝑃𝜉1 =1,5* =735,07 Pa
2

𝐿𝑓𝑖𝑛
𝑛𝑠𝑖𝑐 = -1
𝑙𝑠𝑖𝑐

𝐿𝑓𝑖𝑛 =0,2 m

𝑙𝑠𝑖𝑐 =1,95 m
1,95
𝑛𝑠𝑖𝑐 = -1=8,75~833
0,2

11
3. DESENUL

12

S-ar putea să vă placă și