Sunteți pe pagina 1din 2

UTILITIES / BT / STRUCTURAL 10.

A type of switch that keeps water heated or cooled


© YMF ∞ to selected temperatures.

1. It is a pump designed to be fully immersible within a A. Automatic Cycle Switch B. Waterproof Switch
tank or other media storage receptacle. C. Aquastat C. Thermostat
A. Rotary Pump B. 11. It governs the acceleration, speed, retardation,
Submersible Pump stopping of an Electric Elevator.
C. Sump Pump D. Jet A. Guide Shoes B. Control Panel
Pump
C. Governor D. Motor Generator
2. Used on water systems, heating systems, compressed
air lines & other pipe lines with excessive pressure 17. What kind of foundation is to be used when the
bearing capacity of the soil is low and settlement must
A. Safety Valve B. Check Valve be carefully controlled? The building to be constructed
C. Angle Valve D. Gate Valve weighs approximately the same as the soil excavated for
the substructure, so the stress in the soil beneath the
3. What is the Hot Water Consumption for Residential building is the same after construction as it was before.
buildings?
A. Floating Foundation B. Raft Foundation
A. 4-5 Gallons per person B. 4-6 Gallons per person
C. Deep Foundation D. Mat Foundation
C. 8 Gallons per person D. 10 Gallons per person
18. A two-piece plastic bar that supports a steel
4. How much is the coverage of 1 sprinkler head for reinforcing bar for a structural concrete slab. To the left
Light Hazard occupancies? of the chair, a small concrete brick supporting a second
A. 10 sqm B. 15 sqm. bar in a position closer to the bottom of the slab is also
partially visible.
C. 18 sqm. D. 20 sqm.
A. Tower Chair B. Bench
5. What type of water closet has a flushing action
started by a whirlpool motion followed by a complete C. Bolster D. Joist Chair
flush down. It also retains a large amount of standing 19. What do you call the material used as formwork in a
water. Waffle Slab System to eliminate nonworking concrete
A. Reverse Trap B. Siphon Vortex from the slab, allowing considerably longer spans than
are feasible in the two-way ß at plate system?
C. Wash Down D. Siphon Jet
A. Bins B. Domes
6. What is the minimum center to center distance of
urinals? C. Forms D. Buns

A. .80M B. .75M 20. This occurs when the slope of a low-slope roof is too
shallow. There is a formation of puddles of water that
C. .70M D. .60M stand for extended periods of time, leading to
premature deterioration of the roofing materials in
7. The building sewer extends from the house drain at a
those areas
point ________ from the outside face of the foundation
wall of a building. A. Ponding B. Puddling
A. .50M B. .60M C. Watering D. Water Retention
B. .70M D. .80M 21. A type of glass that imprints the surface of glass with
silkscreened patterns of ceramic-based paints. It is often
8. How many Liters per second does a lavatory
used to control the penetration of solar light and heat
discharge?
into a space.
A. 0.47 liters/second B. 0.52 liters/second
A. Gasochromic Glass B. Patterned Glass
C. 0.57 liters/second D. 0.59 liters/second
C. Fritted Glass D. Art Glass
9. Designed to receive water collecting on the surface of
22. What type of glass glazing supports the head and sill
a roof and to discharge it into a downspout and to
of the glass by metal frames & eliminates mullions and
prevent clogging.
uses a colorless silicone sealant at the vertical joints
A. Roof Drain B. Roof Gutter
A. Structural Glazing B. Butt Joint Glazing
C. Roof Trench D. Roof Catchment
C. Pended Glazing D. Lockstrip Glazing
23-25. Identify what kind of Plaster finish was used in 28.
the photo show below

23.

29.

A. Float Finish B. Spray Finish

C. Texture Finish D. Sponge Finish

24.

30.

31 – 37 identify the kind of Joint Tooling Profile shown


A. Float Finish B. Spray Finish below:

C. Texture Finish D. Sponge Finish Raked Joint Vee Joint Flush Joint Weathered Joint

25. Concave Joint Stripped Joint Struck Joint

31.

32.

A. Float Finish B. Spray Finish

C. Texture Finish D. Sponge Finish

26 – 30 identify the kind of lighting in the photo shown 33.


below

General Lighting Direct Lighting Indirect Lighting


Semi-indirect lighting Semi-direct lighting
34.
26.

35.

27.
36.

37.

S-ar putea să vă placă și