Project: Page # ___

Engineer: 5/22/2019
Descrip: 1
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

GEOMETRY SOIL PRESSURES (Comb: Service)


Column to Column Distance .... 2.45 m Gross Allow. Soil Pressure ..... 170.00 KN/m²
Exterior Interior Overburden Pressure ............. 9.60 KN/m²
Column Length (X) .... 30.0 30.0 cm Reaction Force ....................... 184.5 KN
Column Width (Z) ...... 30.0 30.0 cm Reaction Eccentricity .............. 0.00 m
Edge Distance (X) ..... 0.15 0.15 m NG Ftg. Area in Contact with Soil ...... 100.0 %
Footing Width (Z) ....... 0.80 0.80 m Exterior Interior
Footing Thickness .............. 40.0 cm OK Bearing Pressure ...... 83.86 83.86 KN/m²
Soil Cover ........................... 0.00 m Bearing Ratio ............ 0.49 0.49 OK
Pedestal Height .................. N. A.

APPLIED LOADS SLIDING (Comb. Service)


- Exterior Col. Service Factored Footing-Soil Friction Coeff. ......... 0.35
Axial Force P ........... 86.0 120.0 KN Passive Pressure Coeff. Kp ........ 2.77
Moment about Z Mz 0.0 0.0 KN-m Friction Force at Base ............ 64.6 KN
Shear Force Vx ........ 0.0 0.0 KN Passive Force @ Ftg .............. 3.2 KN
- Interior Col. Service Factored Horiz. Resisting Force ............ 67.8 KN
Axial Force P ........... 86.0 120.0 KN Horiz. Sliding Force ................ 0.0 KN
Moment about Z Mz 0.0 0.0 KN-m Sliding Safety Factor .............. 99.99 > 1.5 OK
Shear Force Vx ........ 0.0 0.0 KN

MATERIALS
Columns Footing
Concrete f'c ............. 20.0 20.0 MPa
Reinf. Steel fy .......... 400.0 400.0 MPa
Soil Cover Density ................. 18.0 KN/m³

DESIGN CODES
Concrete Design ................ ACI 318-14
Load Combinations ............ User-defined

1 of 4
Project: Page # ___
Engineer: 5/22/2019
Descrip: 1
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

OVERTURNING CALCULATIONS (Comb: Service)


OVERTURNING RESISTING
Force Arm Moment Force Arm Moment
- About Z-Z KN m KN-m - About Z-Z KN m KN-m
Ext. Moment Mz ... 0.0 0.0 0.0 Soil Cover ........... 0.0 1.38 0.0
Ext. Shear Vx ....... 0.0 0.40 0.0 Footing Weight ... 21.1 1.38 29.0
Ext. Axial P .......... 0.0 2.60 0.0 Ext. Column ........ 0.0 2.60 0.0
Int. Moment Mz .... 0.0 0.0 0.0 Int. Column .......... 0.0 0.15 0.0
Int. Shear Vx ........ 0.0 0.40 0.0 Ext. Axial P .......... 86.0 2.60 223.6
Int. Axial P .......... 0.0 0.15 0.0 Int. Axial P ........... 86.0 0.15 12.9
Passive Pressure 0.0 0.16 0.0 Water Buoyancy . -8.6 1.38 -11.9
Rh = 0.0 OTM = 0.0 Rv = 184.5 RM = 253.7
Arm of Vertical Resultant .... 1.38 m
Overturning Safety Factor .. 99.99 > 1.5 OK

FOOTING AT EXTERIOR COL.


- One-way Shear (Comb: Factored)
Under-strength ϕ Factor ............. 0.75
- Side + Side
One-way Shear Vux ... 0.0 47.9 KN
Shear Strength ϕVcx .. 139.4 139.4 KN
Max. One-way Shear Ratio Vu/ϕVc .. 0.34 OK
- Punching Shear (Comb: Factored)
Unbalanced Moment Factor Ɣvx ... 0.35
Punching Shear due to Axial .... 237.2 KPa
Punching Shear due to Mz ....... 0.0 KPa
Punching Shear Stress Vu ...... 237.2 KPa
Effective Perimeter bo ............. 116.3 cm
Average Effective Depth d ...... 31.3 cm
Punching Shear Strength ϕVc .. 1106.9 KPa
Punching Shear Ratio Vu/ϕVc ....... 0.21 OK
- Transv. Flexure (Comb: Factored)
Under-strength ϕ Factor ............. 0.90
Footing Effective Length ............. 0.76 m
Use 6 D12 Bars Parallel to Z (Top) , d = 33.2 cm
Use 6 D12 Bars Parallel to Z (Bot) , d = 30.7 cm
Bottom Steel Min. Area Ratio ........ 0.80 OK
Top Bot
Bending Moment Mux .. 0.0 2.5 KN-m
Bending Strength ϕMnx 78.4 72.3 KN-m
Max. Bending Ratio Mux/ϕMnx ....... 0.03 OK
Top Z-Bars Develop. Length Ratio . 1.50 NG
Bot Z-Bars Develop. Length Ratio .. 1.71 NG 2 of 4
Project: Page # ___
Engineer: 5/22/2019
Descrip: 1
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

FOOTING AT INTERIOR COL. LOAD TRANSFER (Comb: Factored)


- One-way Shear (Comb: Factored) Bearing Under-strength ϕ Factor ....... 0.65
Under-strength ϕ Factor ............. 0.75 Ext. Int.
- Side + Side Compressive Stress Pu 1.3 1.3 MPa
One-way Shear Vux ... 58.5 15.8 KN Column Bearing ϕPn ..... 15.0 15.0 MPa OK
Shear Strength ϕVcx .. 139.4 139.4 KN Footing Bearing ϕPn ..... 15.0 15.0 MPa OK
Max. One-way Shear Ratio Vu/ϕVc .. 0.42 OK Shear Force Vu ............. 0.0 0.0 KN
- Punching Shear (Comb: Factored) Shear Friction ϕVn ........ 243.9 243.9 KN OK
Unbalanced Moment Factor Ɣvx ... 0.35 Dowel Steel Area As ..... 13.55 13.55 cm²
Punching Shear due to Axial .... 237.2 KPa Min. Steel Area As min .. 4.50 4.50 cm² OK
Punching Shear due to Mz ....... 0.0 KPa Dev. Length Ratio at Col. 0.49 0.49 OK
Punching Shear Stress Vu ...... 237.2 KPa Dev. Length Ratio at Ftg. 0.46 0.46 OK
Effective Perimeter bo ............. 116.3 cm
Average Effective Depth d ...... 31.3 cm
Punching Shear Strength ϕVc .. 1106.9 KPa
Punching Shear Ratio Vu/ϕVc ....... 0.21 OK
- Transv. Flexure (Comb: Factored)
Under-strength ϕ Factor ............. 0.90
Footing Effective Length ............. 0.76 m
Use 6 D12 Bars Parallel to Z (Top) , d = 33.2 cm
Use 6 D12 Bars Parallel to Z (Bot) , d = 30.7 cm
Bottom Steel Min. Area Ratio ........ 0.80 OK
Top Bot
Bending Moment Mux .. 0.0 2.5 KN-m
Bending Strength ϕMnx 78.4 72.3 KN-m
Max. Bending Ratio Mux/ϕMnx ....... 0.03 OK
Top Z-Bars Develop. Length Ratio . 1.50 NG
Bot Z-Bars Develop. Length Ratio .. 1.71 NG

LONGITUDINAL REINF.
- Long. Flexure (Comb: Factored)
Use 12 D12 Bars Parallel to X (Top) , d = 34.4 cm UPLIFT CALCS (Comb: Service)
Use 12 D12 Bars Parallel to X (Bot) , d = 31.9 cm Uplift Force P ....................... 0.0 KN
Top Bot Pedestals Selfweight ............ 0.0 KN
Min. Steel Area Ratio ... 0.55 0.01 OK Footing Selfweight ................ 21.1 KN
Bending Moment Muz .. 68.1 0.9 KN-m Soil Cover Weight ................. 0.0 KN
Bending Strength ϕMnz 158.0 145.8 KN-m Downward Force W ............. 21.1 KN
Max. Bending Ratio Muz/ϕMnz ....... 0.43 OK Uplift Safety Factor ............... 99.99 > 1.0 OK
Ext. Bot X-Bars Dev. Length Ratio . 1.33 NG
Int. Bot X-Bars Dev. Length Ratio ... 1.33 NG

3 of 4
Project: Page # ___
Engineer: 5/22/2019
Descrip: 1
ASDIP Foundation 3.2.2 COMBINED FOOTING DESIGN www.asdipsoft.com

EXT. COLUMN (Comb: Factored) INT. COLUMN (Comb: Factored)


Use 12-D12 Longitudinal Bars, Use Ties #4 Use 12-D12 Longitudinal Bars, Use Ties D12
Axial Load Pu ...................... 120.0 KN Axial Load Pu ...................... 120.0 KN
Bending Moment Mu ............. 0.0 KN-m Bending Moment Mu ............. 0.0 KN-m
Axial Strength ϕPn ................ 1056.0 KN Axial Strength ϕPn ................ 1056.3 KN
Flexural Strength ϕMn .......... 58.7 KN-m Flexural Strength ϕMn .......... 58.9 KN-m
Biaxial Strength Ratio ................. 0.11 OK Biaxial Strength Ratio ................. 0.11 OK