Documente Academic
Documente Profesional
Documente Cultură
NextGenerationImplantology
Product Catalogue
2014
GenXT
Published by TRATE. We reserve the right to make amendments without notice. All rights reserved.
No information published in this catalogue may be used the written agreement of TRATE, Switzerland.
Questions, comments, and requests can be sent by e-mail to support:GenXT.ch. Website address: www.GenXT.ch.
This catalogue, "GenXT 2014", is valide from 1 January 2014 untill the publication of the next catalogue.
Note: For the purpose of legibility, TRATE does not use ™ or ® in the text.
This does not affect TRATE's rights with regard to registered trademarks.
Disclaimer: some products may not be available in all markets. Please contact your local TRATE representative
to review the product range available. Images of devices in this catalogue may differ from the actual devices.
GenXT
NextGenerationImplantology
Contents
GenXTConcepT
Implantology began with creativity and innovativeness. Somewhere along the
way this was lost, and a monotonous treatment plan was adapted to every patient
This was because of limited understanding of concepts at that time and limitations
in manufacturing. We decided to change that, instead of the doctor and patient
adapting to the limitations of the implant system. We created a system based on
simple biological principles, engineered in a way so that the system adapts to the
doctors innovativeness and patients demands. Ever felt limited by your tools,
GenXT provides with with the tools to excel.
GenXTConcepT
Clinical Viability
Innovative Research
Biologic principles
2
GenXT
ISO ISO
The fact that we have our own global distribution network allows us to guarantee
13485 9001
Medical devices Quality high levels of service.
Quality management
management
3
GenXT
TRATE provides comprehensive service and support via highly qualified representatives
and offers wide range of training services and a website for specialists, including an online shop.
Support
i
TRATE representatives are on hand to help you with any questions you may have
about the GenXT system. They can also assist you in using our online shop.
You can contact our representatives directly or via the form on the website.
Training
We provide a full range of training services to help clinics and laboratories introduce
the GenXTCONCEPT. An online course is available for everybody, 24 hours a day.
For more detailed information, please visit our website at www.GenXT.ch.
Guarantee
Al products are guaranteed for ten years. We liaise closely with our clients
and guarantee to replace failed implants, including the superstructures for reintegration.
Patients literature
We care about your relationship with your patients, so we provide free literature for patients.
A complete literature aimed at patients can be found at the end of this catalogue
and at the online shop.
4
GenXT
5
COMPRESSIVE
Compressive
implants
COMPRESSIVE
21
GenXT
Implant neck
COMPRESSIVE
special design
polished surface
Apical part
Minimal dimensions
22
GenXT
Intraosseous part
special compression thread
radial microthread space
tapered
apical part - small diameter
middle part - medium diameter
pre-cervical part - large diameter
COMPRESSIVE
when inserting into cancellous trabeculae, the special compression implant thread
produces compression, creating a layer of cortical bone around the implant,
with reliable macrofixation
allows immediate implant loading with high primary stability
this compact layer then transforms into cancellous bone,
which is accompanied by osseointegration
23
GenXT
Immediate loading
COMPRESSIVE
24
GenXT
COMPRESSIVE
12 mm C3012 C3512 C4012 C4512 C5012 C5512
16 mm C3016 C3516
25
GenXT
Transfers
Used to take closed transfers of single-component implants. The transfer construction
provides reliable fixation of the transfer in the tray. The preferred material for transfer is
Addition Silicon. The transfer can be modified in case of restricted space.
TRA
Implant analogue
Used for model preparation. Use of plastic provides the model with elasticity corresponding to
the micromobility of the implant. The special antirotation shape prevents macromobility while
working with the analogue, maintaining minimal size preventing interference with placing
when implants are close together.
ANA
Burnout cap
Used to prepare high-precision metal body for precise alignment and to prevent cementing
COMPRESSIVE
BOP failure. The round indicator which matches to the indicator on the abutment shows
the height adjustment of the abutment. The opening in the upper part of the burnout cap,
combined with the colour contrast (red-yellow), gives an accurate impression of the fit
on the analogue, preventing misalignment in clinical situations. Available in Straight , 15
degree , 25 degree and shoulder margin patterns.
Form drilling
Use expansion
Initial drilling Screw if
Check depth Required
and direction Use Drills in Sequence till Implant Diameter
Implant
positioning
C3010
26
GenXT
Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)
Colour indicator - length
Colour indicator - diameter
14 mm
3.0 mm
16 mm
3.5 mm
16 mm 4.0 mm
14 mm 5.0 mm
12 mm 5.5 mm
10 mm
8 mm
COMPRESSIVE
8 mm DC4008 CS4008 CS4508 DC5008 CS5008 DC5508 CS5508
10 mm DC3010 CS3010 DC3510 CS3510 DC4010 CS4010 CS4510 DC5010 CS5010 DC5510 CS5510
12 mm DC3012 CS3012 DC3512 CSS3512 DC4012 CS4012 CS4512 DC5012 CS5012 DC5512 CS5512
14 mm DC3014 CS3014 DC3514 CS3514 DC4014 CS4014 CS4514 DC5014 CS5014 DC5514 CS5514
27
GenXT
Ratchet wrench RW
28
BASAL
Basal
implants
BASAL
29
GenXT
Implant neck
Special design
Polished surface
Depending on the length of the implant the abutment can be bent from
15 - 25 degrees , as long as the implant is placed in sound bone
Surface
BASAL
Polished surface
Implant body
Thin implant body combined with wide thread turns
30
GenXT
Sizes
large diameter
short height
Integration
the implant should always be anchored in basal bone
BASAL
placement of implants in areas not subject to bone resorption
stability of implants essential to allow for osseointigration
31
GenXT
BASAL implants are used to create multiple unit restorations in the upper
and lower jaws. They can be placed in extraction sockets and also in healed
bone. The structural characteristics allow placement in bone that is deficient in
height and width. They can be placed with flap or flapless technique.
A good understanding of the maxillofacial anatomy is recommended so that
bi-cortical engagement is achieved. Can be used to bypass the mandibular
nerve, and for engagement of the cortical bone at the fusion of the pterygoid
with the maxilla. Can be used in combination with compressive implants.
Using a special instrument abutment direction can be adjusted up to 15°
relative to the implant axis.
Immediate loading
Improved abutment
Logic of selection
32
GenXT
10 mm 12 mm 14 mm 16 mm 18 mm 20 mm 22 mm 24 mm 26 mm
Ø 3.5 mm B3510 B3512 B3514 B3516 B3518 B3520 B3522 B3524 B3526
Ø 4.5 mm B4510 B4512 B4514 B4516 B4518 B4520 B4522 B4524 B4526
33
GenXT
Transfers
Used to take closed transfers of single-component implants. The transfer construction
provides reliable fixation of the transfer in the tray. The preferred material for transfer is
Addition Silicon. The transfer can be modified in case of restricted space.
TRA
Implant analogue
Used for model preparation. Use of plastic provides the model with elasticity corresponding
to the micromobility of the implant. The special antirotation shape prevents macromobility
while working with the analogue, maintaining minimal size preventing interference with
placing when implants are close together.
ANA
Burnout cap
Used to prepare high-precision metal body for precise alignment and to prevent cementing
BOP failure. The round groove which matches the groove on the abutment can be used as a
reference for the height adjustment of the abutment. The opening in the upper part of the
burnout cap, combined with the colour contrast (red-yellow), gives an accurate impression of
the fit on the analogue, preventing misalignment in clinical situations.
Implant
positioning
B4514
34
GenXT
Laser-inscribed item ID
the first two numbers show the diameter (mm*10)
the second two numbers show the length (mm)
Colour indicator - length
Colour indicator - diameter
20 mm 18 mm
20 mm 2.0 mm
22 mm 16 mm 2.3 mm
24 mm
26 mm
14 mm
12 mm
10 mm
8 mm
Expansion
Form drills screws
20 mm 22 mm 24 mm 26 mm
BASAL
Ø 2.0 mm DB2020 DB2022 DB2024 DB2026 CS8514
CS1114
D2016
35
GenXT
Ratchet wrench RW
36
GenXT
Notes
42
GenXT
43
GenXT
44
REGIONAL OFFICES
Belarus
TOP RATE IMPLANTS, OOO
Kiseleva st.55-11
220002 Minsk
Latvia
TRATE AG office in Latvia
Ģertrūdes st. 109-1
1009 Riga
Lithuania
TRATE AG office in Lithuania
Vilniaus st. 31/1 (4th Floor, Room No. 6)
01402 Vilnius
Poland
TRATE AG office in Poland
G rczewska st. 24, m.58
01147 Warszawa
Russia
TOP RATE IMPLANTS, OOO
Rustaveli 14-6
127254 Moscow
Spain
TRATE AG office in Spain
Calle de Santiago 19-21
47001 Valladolid
Ukraine
Іnstitut Bіotehnologіj
Srіbnokіl's'ka st.12, sekcіja B
02068 Kiev
REF. CATALOG 12 Printed in Switzerland © TRATE AG, 2012. All rights reserved.
The TRATE logo and other trade marks are registered trade marks of TRATE, unless otherwise stated in the text.
Images of implants at scale 1:1.25
TRATE AG
Seestrasse 58
8806 Bäch
Switzerland
Shanti Dental
Regenics.Implantology@gmail.com
Genxtimplantology.com