Sunteți pe pagina 1din 1

Sections

All sections in the tower must be described in an MStower section


library file. Dimensions and properties are automatically extracted to
compute surface and projected areas when calculating ice and wind loads
and for determining member capacities.

Member Checking
You must ensure that wind velocities and other factors used to compute
loads are consistent with the code method chosen to check member
strengths.
BS 8100 Part 3, AS 3995, ASCE10, TIA-222-G, and IS-802 are limit
states codes, whereas EIA/TIA-222-F uses permissible stresses.

Export to Microstran Archive File


The MStower model may be exported to a Microstran archive file. This
permits running of the model in the Microstran frame analysis and
design program.

Errors
After assembly of the tower, MStower checks for the following
conditions:
Overlaid Members and Unconnected Nodes
These occur when a node is coincident with a member but not connected
to it. When this occurs it is usually at the junction between panels and
happens either because a horizontal has not been deleted or because of
an incompatibility between panels. For example if a PL1 plan brace is
used with an X face brace the PB1 member will overlay the H1 member.
The duplicated member will not be detected by the assembly process
because of the mid-side node in PB1. A list of such members will be
displayed.
Floating Members
These are members that are not connected to the structure. If not
removed they will result in errors during analysis. They can result if
members are deleted; for example if PL1 plan bracing is used with XO
face bracing and the PB1 member is deleted, the internal plan bracing
members will not be connected to the tower. A list of such members will
be displayed.
You may readily locate overlaid and floating members using MStower
screen plots. Select the Show > Members command and then enter the
list of offending members. The full tower will now be displayed with the
listed members highlighted. You may zoom to inspect the members
more closely and determine the reason for the error. The TD or UDP file
should be modified as necessary.

MStower V6.2 4:Operation • 39