Sunteți pe pagina 1din 8

PCT40 Process Control Apparatus - Run 1 Results

Sample Elapsed Notes Temperature Temperature Temperature Flowrate PSV


Number Time Position
T1 T2 T3 F1
[°C] [°C] [°C] [ml/min] [%]
1 00:01 19.9 21.6 21.6 2 0
2 00:11 19.9 20.4 19.9 1128 100
3 00:20 26.0 20.9 19.7 1135 100
4 00:30 30.2 21.7 19.7 1135 100
5 00:40 31.3 22.5 19.7 1136 100
6 00:50 33.6 23.1 19.8 1136 100
7 01:00 35.3 23.7 19.6 1137 100
8 01:10 36.9 24.5 19.7 1140 100
9 01:20 39.3 25.1 19.7 1140 100
10 01:30 40.4 25.7 19.6 1139 100
11 01:40 42.5 26.6 19.7 1143 100
12 01:50 44.6 27.1 19.6 1144 100
13 02:00 45.5 27.8 19.8 1134 100
14 02:10 47.0 28.3 19.7 1136 100
15 02:20 47.6 28.9 19.6 1140 100
16 02:30 48.6 29.6 19.7 1137 100
17 02:40 49.5 30.2 19.8 1138 100
18 02:50 50.7 30.8 19.7 1135 100
19 03:00 51.7 31.3 19.7 1135 100
20 03:10 51.7 31.5 19.7 1137 100
21 03:20 52.6 32.0 19.8 1135 100
22 03:30 53.2 32.3 19.6 1135 100
23 03:40 54.0 32.7 19.7 1128 100
24 03:50 54.7 32.9 19.7 1129 100
25 04:00 54.9 33.3 19.7 1129 100
26 04:10 54.9 33.6 19.7 1128 100
27 04:20 56.3 33.8 19.7 1137 100
28 04:30 56.6 34.0 19.7 1135 100
29 04:40 56.8 34.3 19.9 1132 100
30 04:50 57.9 34.7 19.8 1129 100
31 05:00 58.6 34.8 19.9 1127 100

Page 1
PCT40 Process Control Apparatus - Run 1 Results

32 05:10 58.0 35.0 19.7 1126 100


33 05:20 58.8 35.4 19.7 1126 100
34 05:30 58.9 35.4 19.8 1126 100
35 05:40 58.6 35.5 19.9 1126 100
36 05:50 59.6 35.8 19.8 1121 100
37 06:00 59.9 35.9 19.8 1122 100
38 06:10 59.4 36.1 19.8 1123 100
39 06:20 60.3 36.3 19.8 1119 100
40 06:30 60.4 36.4 19.8 1123 100
41 06:40 60.9 36.7 19.8 1117 100
42 06:50 60.3 36.8 19.8 1118 100
43 07:00 62.0 37.0 19.8 1120 100
44 07:10 61.2 37.3 19.8 1118 100
45 07:20 62.1 37.5 19.9 1118 100
46 07:30 61.3 37.6 19.8 1124 100
47 07:40 62.6 37.6 19.8 1124 100
48 07:50 62.4 37.9 19.8 1113 100
49 08:00 62.6 38.0 19.8 1113 100
50 08:10 62.5 38.0 19.9 1111 100
51 08:20 63.2 38.2 19.9 1113 100
52 08:30 62.8 38.3 19.8 1119 100
53 08:40 63.3 38.4 19.9 1116 100
54 08:50 63.7 38.6 20.0 1113 100
55 09:00 63.1 36.5 19.9 1113 100
56 09:10 60.0 34.8 19.9 1120 100
57 09:20 57.3 33.3 19.9 1113 100
58 09:30 55.3 32.5 19.9 1115 100
59 09:40 52.9 31.6 19.9 1113 100
60 09:50 51.3 30.8 20.0 1110 100
61 10:00 50.3 30.4 20.1 1108 100
62 10:10 48.1 29.6 19.9 1107 100
63 10:20 46.9 29.0 20.0 1108 100
64 10:30 45.8 28.5 20.0 1114 100
65 10:40 44.1 28.1 19.9 1105 100
66 10:50 43.4 27.5 20.0 1110 100
67 11:00 42.4 27.3 19.9 1114 100

Page 2
PCT40 Process Control Apparatus - Run 1 Results

68 11:10 41.6 27.1 20.1 1110 100


69 11:20 40.4 26.6 19.9 1110 100
70 11:30 39.6 26.3 19.9 1104 100
71 11:40 39.2 25.9 19.9 1107 100
72 11:50 38.9 26.3 20.1 1108 100
73 12:00 43.5 28.0 20.0 1105 100
74 12:10 45.4 29.1 20.1 1112 100
75 12:20 49.0 30.0 20.0 1110 100
76 12:30 50.6 31.0 20.1 1107 100
77 14:49 59.9 34.8 20.0 1107 100
78 14:54 58.8 34.0 20.0 1110 100
79 15:04 55.6 32.5 20.0 1108 100
80 15:14 53.5 31.6 20.0 1106 100
81 15:24 51.4 30.7 20.0 1110 100
82 15:34 49.3 30.0 20.0 1105 100
83 15:44 47.9 29.5 20.0 1102 100
84 15:54 46.4 28.8 20.0 1102 100
85 16:04 45.1 28.4 20.0 1105 100
86 16:14 43.8 27.8 20.1 1104 100
87 16:24 42.9 27.4 20.0 1100 100
88 16:34 42.0 27.1 20.1 1102 100
89 16:44 40.9 26.9 20.0 1103 100
90 16:54 40.0 26.5 20.0 1103 100
91 17:04 39.2 26.2 20.0 1102 100
92 17:14 38.3 26.0 20.1 1100 100
93 17:24 37.6 25.6 20.1 1105 100
94 17:34 39.0 26.4 20.1 1107 100
95 17:44 41.7 28.0 20.0 1100 100
96 17:54 44.4 28.8 20.0 1104 100
97 18:04 47.8 30.0 20.1 1099 100
98 18:14 49.8 30.8 20.0 1103 100
99 18:24 51.7 31.4 20.0 1107 100
100 18:34 51.9 32.1 20.0 1099 100
101 18:44 53.7 32.7 20.1 1101 100
102 18:54 54.7 33.2 20.0 1101 100
103 19:04 54.7 33.8 20.1 1105 100

Page 3
PCT40 Process Control Apparatus - Run 1 Results

104 19:14 54.5 34.2 20.0 1100 100


105 19:24 56.5 34.4 20.1 1107 100
106 19:34 56.7 34.8 20.0 1111 100
107 19:44 57.8 35.2 20.0 1110 100
108 19:54 57.6 35.5 19.9 1107 100
109 20:04 58.7 35.7 20.0 1114 100
110 20:14 59.2 34.3 20.0 1113 100
111 20:24 56.3 32.7 20.0 1113 100
112 20:34 53.2 31.4 20.0 1113 100
113 20:44 51.7 30.6 20.0 1107 100
114 20:54 49.4 29.8 20.0 1107 100
115 21:04 47.9 29.2 20.0 1107 100
116 21:14 46.4 28.7 20.1 1111 100
117 21:24 45.1 28.1 20.0 1104 100
118 21:34 43.8 27.7 20.0 1107 100
119 21:44 42.8 27.2 20.1 1104 100
120 21:54 41.7 27.1 20.1 1104 100

Page 4
PCT40 Process Control Apparatus - Run 1 Results

Hot Thermostat Heater


Pump State State
Setting
[%]
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On

Page 5
PCT40 Process Control Apparatus - Run 1 Results

0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off

Page 6
PCT40 Process Control Apparatus - Run 1 Results

0 0 Off
0 0 Off
0 0 Off
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 1 On

Page 7
PCT40 Process Control Apparatus - Run 1 Results

0 1 On
0 1 On
0 1 On
0 1 On
0 1 On
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off
0 0 Off

Page 8