Documente Academic
Documente Profesional
Documente Cultură
HighWall Mounted
WWD Series
1.Introduction
The WWD high wall mounted fan coil units delivers a high standard of air quality characteristics in many application. With the
features of extremely quiet, suitable for most public buildings and private house. Units are standard equipped with remote
controller and nylon filter.
2.Design Features
Both EC & AC Motor Design Are Available
This range can be installed either the EC motor or AC motor.
Both ranges are with remote control.
φ3/8” (9.52mm) Copper Tube Heat Exchanger Coil (Heat Exchanger) is construced of Φ3/8” seamless copper tubes.
Aluminium blue fines are mechanically bonded to copper It is with much higher efficiency than triditional Φ1/4” copper
tube heat exchanger and with much smaller water-resistant, not easy to get tube jam.tubes.
1
www.innovair.com
High Wall Mounted
Chilled Water WWD Series
General Data
Spec Item Unit WWD-002 WWD-003 WWD-004 WWD-005 WWD-006 WWD-008
Nominal Air
CFM 200 300 400 500 600 800
volume
Copper tube 3/8”(9.52mm)OD seamless copper tube
Fins Hi-efficiency aluminium blue fins
Coil Fins per
FPI 14 14 14 14 14 14
Inch
Fan type Cross flow, direct driven
Fan
Qty pcs 1 1 1 1 1 1
Voltage 220-240V/1Ph/50-60HZ,110-127V/1Ph/50HZ
Motor
3-speed AC or EC Motor
speed
Qty pcs 1 1 1 1 1 1
Power input
Motor W(H/M/L) 10/8/6 13/10/8 20/13/10 30/20/13 45/24/18 55/34/22
EC
Power input
W(H/M/L) 26/23/21 40/34/30 42/36/29 63/47/36 75/64/45 90/72/55
AC
Noise level H d B(A) 37 40 42 46 47 49
at 1.0m M d B(A) 34 37 40 43 41 45
distance L d B(A) 31 34 37 40 38 41
Water pipe Cooling coil 1/2”FTP 1/2”FTP 1/2”FTP 1/2”FTP 1/2”FTP 1/2”FTP
Drain pipe 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
L mm 875 875 1115 1115 1115 1250
Package
W mm 340 340 385 385 385 360
Dimension
H mm 290 290 315 315 315 320
Net Weight kg 10 10 17 17 17 24
2
www.innovair.com
High Wall Mounted
Chilled Water WWD Series
Performance Data
Standard rating conditions as follows:
Cooling: Heating:
Entering air temperature: +27°C DB; +19.50°CWB Entering air temperature: +20°C DB
Water inlet/outlet: +7/12°C Water inlet temperature: +60°C
Water flow same as cooling condition
2-pipe; 2-row Heat Exchanger
Note: Air flow is tested in the condition that the fan coil heat exchanger is dry.
3
www.innovair.com
High Wall Mounted
Chilled Water WWD Series
Dimension Data
Model A B C
WWD-002 784 283 218
WWD-003 784 283 218
WWD-004 1050 318 237
WWD-005 1050 318 237
WWD-006 1050 318 237
WWD-008 1178 340 250
Standard WWD series fan coil units are without valve package. Customer can choose valve package and we can help customer to
make it factory fitted or customer can buy the valve and install the valve inside the fan coil by himself. The PWFC design is with
enough space of installing the vaive inside the units.
4
www.innovair.com