Sunteți pe pagina 1din 2

Project: CA TAM OIL FIELD DEVELOPMENT

Rev.: 1
Date: 14/08/2018

Crude oil heater unit - Piping List

INSULATION
PRESSURE [BARG] TEMPERATURE [°C] FLOWRATE DENSITY [KG/M3] SPEED [M/S]

THICKNESS
DIAMETER
EXTERNAL

REVISION
RATING
CLASS

FLUID

INTERNAL

DESIGN

DESIGN
[MC/H]
N° N.D. LINE FROM TO OPERATING OPERATING DESIGN OP. [SMC/H] (3) DESIGN DESIGN
DIAMETER
Min Max Min Max MIN MAX Min Max MINIMUM MAX
0623 AS1 AU #150 2" N 60,33 3,91 52,51 AU-AS1-2"-0623-N Instrument air header 4 9 13 20 45 20 100 4 400 94 5,5 12,1 0
0624 AS1 AU #150 1 1/2" N 48,26 5,08 38,10 AU-AS1-1 1/2"-0624-N Instrument air header Pilot Burner B-603 0,4 0,6 13 20 45 20 100 20 40 33 1,5 8,1 1
0625 AS1 AU #150 1 1/2" N 48,26 5,08 38,10 AU-AS1-1 1/2"-0625-N Instrument air header Pilot Burner B-604 0,4 0,6 13 20 45 20 100 20 40 33 1,5 8,1 1
0626 AC1 FG #150 3" N 88,90 7,62 73,66 FG-AC1-3"-0626-N Fuel gas inlet TIE IN POINT TP-0609 SSV-0637 upstream 2,4 3,2 3,6 22 32 20 60 70 700 232 2,7 15,1 1
0627 AC1 FG #150 2" N 60,33 5,54 49,25 FG-AC1-2"-0627-N Bypass of PCV-0638 2,4 3,2 3,6 22 32 20 60 70 400 133 2,7 19,3 1
0628 AC1 FG #150 2" N 60,33 5,54 49,25 FG-AC1-2"-0628-N Blanket gas to T-600 2,4 3,2 3,6 22 32 20 60 0,1 10 3 2,7 0,5 1
0629 AC1 FG #150 4" N 114,30 6,02 102,26 FG-AC1-4"-0629-N SSV-0637 downstream TEE to burners 1,3 1,7 3,6 22 32 20 60 70 700 343 1,8 11,6 1
0630 AC1 VH #150 1" N 33,40 6,35 20,70 VH-AC1-1"-0630-N FG-AC1-4"-629-N Vent line 1,3 1,7 3,6 22 32 20 60 0,1 0,1 0 1,8 0,0 1
0631 AC1 FG #150 3" N 88,90 7,62 73,66 FG-AC1-3"-0631-N Reducer from tee split flow Burner B-602 1,3 1,7 3,6 22 32 20 60 35 350 171 1,8 11,2 1
0632 AC1 FG #150 1/2" N 21,34 4,78 11,78 FG-AC1-1/2"-0632-N Upstream SSOV-0657 Pilot burner B-604 0,4 0,6 3,6 22 32 20 60 2 3 2 1,1 6,1 1
0633 AC1 FG #150 1/2" N 21,34 4,78 11,78 FG-AC1-1/2"-0633-N Bypass of PCV-0638 0,4 0,6 3,6 22 32 20 60 2 3 2 1,1 6,1 1
0634 AC1 VH #150 1/2" N 21,34 4,78 11,78 VH-AC1-1/2"-0634-N Tightness test vent line of B-602 1,3 1,7 3,6 22 32 20 60 0,1 0,1 0 1,8 0,3 1
0635 AC1 FG #150 3" N 88,90 7,62 73,66 FG-AC1-3"-0635-N Reducer from tee split flow Burner B-601 1,3 1,7 3,6 22 32 20 60 35 350 171 1,8 11,2 1
0636 AC1 FG #150 1/2" N 21,34 4,78 11,78 FG-AC1-1/2"-0636-N Upstream SSOV-0647 Pilot burner B-603 0,4 0,6 3,6 22 32 20 60 2 3 2 1,1 6,1 1
0637 AC1 FG #150 1/2" N 21,34 4,78 11,78 FG-AC1-1/2"-0637-N Bypass of PCV-0645 0,4 0,6 3,6 22 32 20 60 2 3 2 1,1 6,1 1
0638 AC1 VH #150 1/2" N 21,34 4,78 11,78 VH-AC1-1/2"-0638-N Tightness test vent line of B-601 1,3 1,7 3,6 22 32 20 60 0,1 0,1 0 1,8 0,3 1
0639 AC1 DC #150 2" N 60,33 5,54 49,25 DC-AC1-2"-0639-N GH-600 drain N11 Close drain TIE POINT TP-0610 0 0,3 2 20 40 20 100 - - 15 994,4 2,2 0
0640 AC1 DC #150 2" N 60,33 5,54 49,25 DC-AC1-2"-0640-N HE-600 and pumps drains DC-AC1-2"-0639-N 0 0,3 2 20 40 20 100 - - 15 994,4 2,2 0
0641 AC1 GY #150 10" IH 273,05 9,27 254,51 GY-AC1-10"-0641-IH Glycol heater outlet N9 Pump P-600A suction 1 1,5 7 80 120 20 150 20 122 122 949,3 0,7 1
0642 AC1 GY #150 6" IH 168,28 7,11 154,06 GY-AC1-6"-0642-IH Hot glycol pump recirculation Glycol heater inlet nozzle N5 3 3,5 7 80 120 20 150 20 122 122 949,3 1,8 1
0643 AC1 GY #150 6" IH 168,28 7,11 154,06 GY-AC1-6"-0643-IH HE-600 Shell side outlet nozzle N25 Glycol heater inlet nozzle N4 3 3,5 7 80 120 20 190 20 122 122 949,3 1,8 1
0644 AC1 GV #150 2" IH 60,33 5,54 49,25 GV-AC1-2"-0644-IH Glycol heater and tank pressure balancing 1 1,5 7 80 120 20 190 - - 0 3,1 0,0 1
0645 AC1 VH #150 2" IP 60,33 5,54 49,25 VH-AC1-2"-0645-IP T-600 vent nozzle N13 VH-AC1-4"-0650-IP 1 1,5 7 80 120 20 190 - 122 104 3,1 15,2 1
0646 AC1 VH #150 1" IP 33,40 6,35 20,70 VH-AC1-1"-0646-IP Bypass of PCV-0669 1 1,5 7 80 120 20 190 - - 20 3,1 16,5 1
0647 AC1 VH #150 3" IP 88,90 7,62 73,66 VH-AC1-3"-0647-IP Safety pressure relief valves nozzle N14 PSV-0668A 1 1,5 7 - - 20 190 - - 314 10,7 20,5 1
0648 AC1 VH #150 3" IP 88,90 7,62 73,66 VH-AC1-3"-0648-IP VH-AC1-2"-0647-IP PSV-0668B 1 1,5 7 - - 20 190 - - 314 10,7 20,5 1
0649 AC1 VH #150 4" IP 114,30 6,02 102,26 VH-AC1-4"-0649-IP PSV-0668B VH-AC1-4"-0650-IP 2 2 2 - - 20 190 - - 721 4,6 24,4 1
0650 AC1 VH #150 4" IP 114,30 6,02 102,26 VH-AC1-4"-0650-IP PSV-0668A Vent header 2 2 2 - - 20 190 - - 721 4,6 24,4 1
0651 AC1 DH #150 1/2" N 21,34 4,78 11,78 DH-AC1-1/2"-0651-N PCV-0668B downstream open drain 0 0 2 22 40 20 100 - - 1 994,4 2,5 0
0652 AC1 DH #150 1/2" N 21,34 4,78 11,78 DH-AC1-1/2"-0652-N PCV-0668A downstream open drain 0 0 2 22 40 20 100 - - 1 994,4 2,5 0
0653 AC1 GY #150 10" IH 273,05 9,27 254,51 GY-AC1-10"-0653-IH Pump P-600B suction line 1 1,5 7 80 120 20 150 20 122 122 949,3 0,7 1
0654 AC1 GY #150 4" IH 114,30 6,02 102,26 GY-AC1-4"-0654-IH Bypass of PCV-0681 3 3,5 7 80 120 20 150 20 122 122 949,3 4,1 1
0655 AC1 VH #150 4" IP 114,30 6,02 102,26 VH-AC1-4"-0655-IP HE-600 Safety relief valves nozzle N26 PSV-0689A 3 3,5 7 - - 20 190 - - 79 833,3 2,7 1
0656 AC1 VH #150 4" IP 114,30 6,02 102,26 VH-AC1-4"-0656-IP VH-AC1-4"-0655-IP PSV-0689B 3 3,5 7 - - 20 190 - - 79 833,3 2,7 1
0657 AC1 VH #150 6" IP 168,28 7,11 154,06 VH-AC1-6"-0657-IP PSV-0689B Vent header 0 0 2 - - 20 190 - - 79 833,3 1,2 1
0658 AC1 VH #150 6" IP 168,28 7,11 154,06 VH-AC1-6"-0658-IP PSV-0689A Vent header 0 0 2 - - 20 190 - - 79 833,3 1,2 1
0659 AC1 DH #150 1/2" N 21,34 4,78 11,78 DH-AC1-1/2"-0659-N PCV-0689A downstream open drain 0 0 2 22 40 20 100 - - 1 994,4 2,5 0
0660 AC1 DH #150 1/2" N 21,34 4,78 11,78 DH-AC1-1/2"-0660-N PCV-0689B downstream open drain 0 0 2 22 40 20 100 - - 1 994,4 2,5 0
0661 AC1 DH #150 1" N 33,40 6,35 20,70 DH-AC1-1"-0661-N P-600A drain DC-AC1-2"-0640-N 0 0 2 22 60 20 100 - - 1 987,4 0,8 0
0662 AC1 DH #150 1" N 33,40 6,35 20,70 DH-AC1-1"-0662-N P-600B drain DC-AC1-2"-0640-N 0 0 2 22 60 20 100 - - 1 987,4 0,8 0
0663 AC1 GY #150 1" N 33,40 6,35 20,70 GY-AC1-1"-0663-N Pumps discharge line drain DC-AC1-2"-0640-N 0 0 2 22 60 20 100 - - 1 987,4 0,8 0
0664 AC1 GY #150 1" N 33,40 6,35 20,70 GY-AC1-1"-0664-N HE-600 shell drain DC-AC1-2"-0640-N 0 0 2 22 60 20 100 - - 1 987,4 0,8 0
0665 AC1 GY #150 4" N 114,30 6,02 102,26 GY-AC1-4"-0665-N Bypass of TCV-0698 3 3,5 7 80 120 20 150 20 122 122 949,3 4,1 1
0666 BC1 PL #300 6" IE 168,28 7,11 154,06 PL-BC1-6"-0666-IE Crude oil inlet TIE IN TP-0614 Crude oil exchanger inlet 16 22 45 25 35 20 150 - - 228 849,7 3,4 1
0667 BC1 PL #300 8" IH 219,08 8,18 202,72 PL-BC1-8"-0667-IH Crude oil exchanger outlet Crude oil TIE POINT TP-0613 16 22 45 60 80 20 150 - - 228 849,7 2,0 1

Pagina 2 di 4
Project: CA TAM OIL FIELD DEVELOPMENT
Rev.: 1
Date: 14/08/2018

Crude oil heater unit - Piping List

INSULATION
PRESSURE [BARG] TEMPERATURE [°C] FLOWRATE DENSITY [KG/M3] SPEED [M/S]

THICKNESS
DIAMETER
EXTERNAL

REVISION
RATING
CLASS

FLUID

INTERNAL

DESIGN

DESIGN
[MC/H]
N° N.D. LINE FROM TO OPERATING OPERATING DESIGN OP. [SMC/H] (3) DESIGN DESIGN
DIAMETER
Min Max Min Max MIN MAX Min Max MINIMUM MAX
0668 BC1 VH #300 2" IP 60,33 5,54 49,25 VH-BC1-2"-0668-IP PL-BC1-8"-0667-IH PSV-0696 inlet 0 0 45 - - 20 358 - - 12 367,1 1,7 1
0669 AC1 VH #150 3" IP 88,90 7,62 73,66 VH-AC1-3"-0669-IP PSV-0696 outlet Vent header 0 0 2 - - 20 358 - - 12 367,1 0,8 1
0670 AC1 VH #150 6" IP 168,28 7,11 154,06 VH-AC1-6"-0670-IP Vent header 0 0 2 - - 20 358 - - 79 833,3 1,2 1
0671 AC1 GY #150 6" IP 168,28 7,11 154,06 GY-AC1-6"-0671-IP P-600B discharge Crude oil heat exchanger N24 3 3,5 7 80 120 20 150 20 122 122 949,3 1,8 1
0672 AC1 GY #150 6" IP 168,28 7,11 154,06 GY-AC1-6"-0672-IP P-600A discharge GY-AC1-6"-0671-IP 3 3,5 7 80 120 20 150 20 122 122 949,3 1,8 1
0673 AC1 FG #150 1" N 33,40 6,35 20,70 FG-AC1-1"-0673-N Bypass of PCV-0670 2,4 3,2 13 22 32 20 60 0,1 10 3 2,7 2,7 1

Notes:
(1) GY= Glycol liquid phase; GV = Glycol vapor phase; PG = Process Gas; DC = Closed Drain ; VH = Hot Vent; AU = Utility air; FG = Fuel Gas
(2) Flowrate of liquid flows (DC) is in mc/h
(3) Standard conditions 0°C and 101325 Pa