INTRODUCTION
1
CHAPTER 2
LITERATURE REVIEW
2
CHAPTER 3
3
A practical thermoelectric module generally consists of two or more
elements of n and p-type doped semiconductor material that are connected
electrically in series and thermally in parallel. These thermoelectric elements and
their electrical interconnects typically are mounted between two ceramic
substrates. The substrates hold the overall structure together mechanically and
electrically insulate the individual elements from one another and from external
mounting surfaces. Most thermoelectric modules range in size from approximately
2.5-50 mm (0.1 to 2.0 inches) square and 2.5-5mm (0.1 to 0.2 inches) in height. A
variety of different shapes, substrate materials, metallization patterns and mounting
options are available.
4
CHAPTER 4
CLASSIFICATION OF TEM
6
Now a days the thermoelectric modules have the common problem of rapid
degradations which is basically about 5% for a 2000C temperature of hot side for
600 hours or we can say that it’s tough to find out efficient and
reliable thermoelectric generator. The problem can be solved by creating the
temperature stable at 2000C – 2500C.
Although Peltier effect was discovered more than 150 years ago,
thermoelectric devices have only been applied commercially during recent
decades. Lately, a dramatic increase in the application of TE solutions in
optoelectronic devices has been observed, such as diode lasers, photo detectors,
solid- state pumped lasers, charge-coupled devices (CCDs) and others. The
thermoelectric module consists of thermocouple formed by pairs of P-type and N-
type semi-conductor thermo element which are electrically connected in series
configuration and thermally connected in parallel configuration. Due to their solid
state construction the modules are considered to be highly reliable. For most
application they will provide long, trouble free service. For cooling application, an
7
electrical current supply is given to the module, heat is transferred from one side to
the other, and the result is that the module will become cooler at one side and
hotter at the other side.
The figure 4.2 shows a particular thermoelectric module assembly. The main
advantages of using TE modules in cooling applications are, they are solid state,
have no moving parts and are miniature in size, its reliability and flexibility in
design to meet particular requirements.
8
The figure 2.2 shows the working of thermoelectric module. When a DC
voltage is applied to the TE module, the positive and negative charge carriers in the
pellet assemblage absorb heat energy from one of the surface and reject it to the
other at the opposite side. The surface area where heat energy is absorbed gets
cooler; the opposite surface where heat energy is released gets hotter. Reversing
the polarity will result in reversed hot and cold sides.
In this proposed work, the main aim is to develop a refrigeration system with
a capacity of 40L of cooling chamber. It is necessary to design a system capable of
maintaining the temperature of the materials between 100C to 15 0C for a long
duration. Since the system has to be used in remote areas where power is scarce,
alternative sources of energy like battery or solar power has to be incorporated in
the design. Moreover the system is meant for outdoor use which makes better
insulation and radiation control mandatory. In order to meet worse scenario, even
though the system is to designed for maintaining a fixed chamber temperature
9
throughout the operational period, the design should be such that it can adaptable
for refrigerating the chamber from ambient temperature to the required
temperature.
10
CHAPTER 5
1. Thermoelectric Cooler
4. 220V AC fan
5. AC-DC convertor
6. Thermal grease
8. Temperature indicator
When coupled with an appropriate heat sink and power source, TEC1 Peltier
Modules are suitable for the following applications…
11
Food and Beverage Refrigeration – Precision temperature management
allows for use in temperature sensitive food and beverage refrigeration
applications requiring exacting cooling (or heating).
Commercial Portable Cooling – Approved for use in commercial transport,
TEC1 Peltier Modules can be applied to manage DTmax temperatures of up
to 68˚C.
Temperature Stabilization – Stabilize volatile temperatures with ease and
superior energy efficiency when paired with a precision Peltier control
module.
Precision Temperature Control – For research laboratories, universities, or
any precision temperature control situation with a range of up to 68˚C, TEC1
Peltiers provide unparalleled control.
Medical and Photonic Systems – Trusted in thousands of medical and
photonic systems applications, TEC1 Peltier Modules offer premier
precision temperature control - even in extreme temperature differentials -
few coolers can match.
12
5.2 Heat sink(Hot side)
A heat sink is a passive heat exchanger that transfers the heat generated by
an electronic or a mechanical device to a fluid medium. Size 120x60x40mm.
A heat sink is designed to maximize its surface area in contact with the
cooling medium surrounding it, such as the air. Air velocity, choice of material,
protrusion design and surface treatment are factors that affect the performance of a
heat sink. Heat sink attachment methods and thermal interface materials also affect
the die temperature of the integrated circuit. Thermal adhesive or thermal
grease improve the heat sink's performance by filling air gaps between the heat
sink and the heat spreader on the device. A heat sink is usually made out of copper
or aluminium. Copper is used because it has many desirable properties for
thermally efficient and durable heat exchangers. First and foremost, copper is an
excellent conductor of heat. This means that copper's high thermal conductivity
allows heat to pass through it quickly. Aluminium heat sinks are used as a low-
cost, lightweight alternative to copper heat sinks, and have a lower thermal
conductivity than copper.
13
5.3 Heat sink(Cold side)
A heat sink is a passive heat exchanger that transfers the heat generated by
an electronic or a mechanical device to a fluid medium, often air or a liquid
coolant, where it is dissipated away from the device, thereby allowing regulation of
the device's temperature at optimal levels. In computers, heat sinks are used to
cool central processing units or graphics processors. Heat sinks are used with high-
power semiconductor devices such as power transistors and optoelectronics such as
lasers and light emitting diodes (LEDs), where the heat dissipation ability of the
component itself is insufficient to moderate its temperature. Size 120x60x40mm
14
Fig 5.4 Heat sink(Cold side)
2 set of 12v DC supply fan is used at the back side of heat sink. This will
dissipate heat from sink. 3*3 inch Brushless Fan. Generally used in system, panel
box etc to keep the system cool. Specifications. Size: 3 × 3-inch (80 x 80 x
25mm); DC: 12V 0.20A. Speed: 3000 RPM; Blades : 7 blade cooling fan. Very
low noice; Material: hard plastic. Color: black. Image shown is a representation
only.
15
Fig 5.5 DC Cooling fan
5.5 AC fan
220V Ac fan of size 120x120x28mm used to extract heat from hot side of
TEC. This will speed up the heat dissipation. The AC cooling fan has become an
essential component in nearly all modern electronics products. These fans supply
the apparatus with cool air and create efficient air flow over the device so that it
may operate correctly and at its full ability. Computer and electronics AC fans
function in the same capacity as any regular household fan. The main purpose of
these fans is to ensure that acceptable temperatures are maintained in an electronic
device. The blades spin at different rates proportionately to the required amount
of cooling. Together the device and fan
16
Fig 5.6 AC Fan
17
Fig 5.7 AC-DC convertor
18
always comprises of the same essential elements, and may have one or more stages
of conversion. The converter depicted in figure 1 is called a ‘forward converter”,
which is a higher efficiency than a slightly simpler architecture; a ‘flyback
converter’. Although not discuss in detail, a flyback converter differs from a
forward converter in that its operation depends upon energy stored in the airgap of
the transformer in the circuit. Apart from this difference, they can utilize the same
essential blocks.
19
Fig 5.8 Thermal grease
Heating and cooling cabin with size of 30x60x60cm of each were designed
Plywood used as cabin
20
Fig 5.9 Cooling and heating cabin
To avoid heat loss to the walls here we used thermocol as heat insulator
21
Fig 5.10 Air flow duct
22
Negative Temperature Coefficient (NTC) thermistors exhibit a decrease in
electrical resistance when subjected to an increase in body temperature and
Positive Temperature Coefficient (PTC) thermistors exhibit an increase in
electrical resistance when subjected to an increase in body temperature.
23
CHAPTER 6
24
Amount of heat to be absorbed at the TEC’s cold surface. This can also be
termed as heat load. It is represented as (Qc) and the unit is Watts.
Operating current (I) and operating voltage (V) of the TEC.
If the object to be cooled is in direct contact with the cold surface of the
TEC, the required temperature can be considered the temperature of the cold side
of TEC (Tc).Here in this project the object is air inside the car, which has to be
cooled when passed through a cluster of four Aluminum heat sinks. It is discussed
in detail in the next chapter. The aim is to cool the air flowing through the heat
sinks. When this type of system is employed the cold side temperature of the TEC
is needed to be several time colder than the ultimate desired temperature of the air.
The hot side temperature (Th) is mainly based on the two factors. First
parameter is the temperature of the ambient air in environment to which the heat is
been rejected. Second factor is the efficiency of the heat sink that is between the
hot side of TEC and the ambient.
ΔT = Th -Tc
Actual ΔT is not same as the system ΔT. Actual ΔT is the difference between the
hot and cold side of the TEC. On the other hand system ΔT is the temperature
25
difference between the ambient temperature and temperature of the load to be
cooled.
The most difficult and important factor to be accurately calculated for a TEC
is the amount of heat to be removed or absorbed (Qc) by the cold side of the TEC.
In this project Qc was calculated by finding the product of mass flow rate of air,
specific heat of air and temperature difference. Here the temperature difference
system ΔT in the difference between the inlet temperature and outlet temperature
of the cooling system. The mathematical equation for Qc is as shown below.
Qc = m CpΔT
26
2 to 5 °C for cooling using liquid heat exchangers - Liquid cooled.
There are several different types of heat exchangers available in the market.
As far this project is concerned a forced convection type of heat sink was be used
based on the ΔT. The main heat sink parameter for the selection process is its
thermal resistance. Heat sink resistance can be termed as the measure of the
capability of the sink to dissipate the applied heat. The equation is as follows.
R = (Th-TΔ )/Qh
R is the thermal resistance (in oC /W or K/W) and Th, the hot side
temperature and T∞ ambient temperature respectively. Qh is the heat load into the
heat sink which is the sum of TEC power Pe and heat absorbed.
Q h=Qc+Pe
The goal of a heat sink design is to lessen the thermal resistance. It can be
attained through exposed surface area of the heat sink. It may also require forced
air or liquid cooling.
Power supply and temperature control are two added items that must be
considered wisely for a successful TE system. TEC is a direct current device. The
quality of the DC current is important. Current and voltage of a TEC can be
determined by the charts provided by the manufacturer. TEC’s power is the
product of required voltage and current. (P = IV).
Temperature control is generally categorized into two groups. One is open loop or
manual and the other is closed loop or automatic. For cooling systems normally
cold side is used as basis of control. The controlled temperature is compared to the
27
ambient temperature. An on-off or a control using thermostat is the simplest and
easiest techniques to control the temperature of a TEC.
28
CHAPTER 7
EXPERIMENTAL ANALYSIS
7.1 Cooling load calculation
The amount of heat removed or the cooling power was determined before
selection of the TEC. Qc which is the amount of heat absorbed was calculated
using the equation
(Qc = m CpΔT )
Mass flow rate (m) of air is the product of density of air (p) and volume flow
rate (Q ). Density of air at 30 °C was taken as1.164 kg / m3. Q was obtained by
multiplying velocity of air pass through the rectangular duct of heat sinks and the
cross section area of a heat sink. It is denoted by the equation (Q =V × A ).
Velocity of the air passing through the duct was measured using an anemometer
and resulted in a reading of5m /s. Cross sectional area of the rectangular duct (W
×H) was calculated as 0.0054128m2 and the volume flow rate was 0.02706m3 / s .
Specific heat of air (C ) at 30 °C was taken as1007 J / kgK.
29
Table 7.1 Temperature variance – cooling process
0
min C
1 0 33.2
2 5 31.4
3 10 30.8
4 15 29.2
5 20 28.0
6 25 27.4
7 30 26.9
8 35 26.6
9 40 26.4
10 45 26.4
Temperature
35
30
25
20
15 Temperature
10
0
0 5 10 15 20 25 30 35 40 45
All calculations used in the project ,related to cooling load , selection of heat
sinks, selection of fans, pressure drop calculations, surface area needed to cool the
air etc. are mentioned below-
Cooling load-
𝑄𝑐 = 𝑚𝐶𝑝 ∆𝑇
𝑞̇ = V x A= Velocity x Area
𝑘𝑔
𝑚 = 1.164 × 0.015 = 0.01746
𝑠
31
∆𝑇 = 33.2 − 26.4 = 6.8 𝐾
𝑄𝑐 = 𝟏𝟏𝟗. 𝟓 𝑲𝑱/𝒔
𝑸𝒉 was calculated by adding the electrical power input and the cooling load.
𝑸𝒉 = 𝑄𝑐 + 𝑃𝑒
𝑃𝑒 = 3 x 57.4= 172.2KJ/s
Coefficient of Performance
𝑄𝑐
𝐶𝑂𝑃 =
𝑃𝑒
119.5
𝐶𝑂𝑃 = = 0.69
172.2
Mass flow rate (m) of air is the product of density of air (p) and volume flow
rate (Q ). Density of air at 30 °C was taken as1.164 kg / m3. Q was obtained by
multiplying velocity of air pass through the rectangular duct of heat sinks and the
cross section area of a heat sink. It is denoted by the equation (Q =V × A ).
Velocity of the air passing through the duct was measured using an anemometer
and resulted in a reading of5m /s. Cross sectional area of the rectangular duct (W
×H) was calculated as 0.0054128m2 and the volume flow rate was 0.02706m3 / s .
Specific heat of air (C ) at 30 °C was taken as1007 J / kgK
32
Table 7.2 Temperature variance – Heating process
1 0 33.4
2 5 35.4
3 10 39.5
4 15 43.5
5 20 44.8
6 25 47.4
7 30 49.6
8 35 51.8
9 40 52.3
10 45 52.3
Temperature
60
50
40
30
Temperature
20
10
0
0 5 10 15 20 25 30 35 40 45
All calculations used in the project ,related to cooling load , selection of heat
sinks, selection of fans, pressure drop calculations, surface area needed to cool the
air etc. are mentioned below-
Cooling load-
𝑄𝑐 = 𝑚𝐶𝑝 ∆𝑇
𝑞̇ = V x A= Velocity x Area
34
𝑘𝑔
𝑚 = 1.164 × 0.015 = 0.01746
𝑠
𝑄𝑐 = 𝟑𝟑𝟓. 𝟖 𝑲𝑱/𝒔
𝑸𝒉 was calculated by adding the electrical power input and the cooling load.
𝑸𝒉 = 𝑄𝑐 + 𝑃𝑒
𝑃𝑒 = 3 x 57.4= 172.2KJ/s
Coefficient of Performance
𝑄𝑐
𝐶𝑂𝑃 =
𝑃𝑒
335.8
𝐶𝑂𝑃 = = 1.95
172.2
35
CHAPTER 8
CONCLUSION
A Thermoelectric Air cooling & heating system was designed and built
which can be used for personal cooling & heating. Four TECs were used for
achieving the cooling with a DC power supply through external power supply
(dimmer stat). It had been shown from testing results that the cooling system is
capable of cooling & heating the air when re circulating the air with the help of
from33.2°C to 26.4°C. Cooling stabilizes within ten minutes once the blower is
turned ON (with a velocity of 2.5 m/s). The system can attain a temperature
difference of set target which was 6°C. TEC designed was able to heat an ambient
air temperature from33.5°C to 52.3°C. . With a single TEC, one hot side and a cold
side heat sink a smaller personal TEC cooler which gives comfort can be fabricated
and can be installed on roof for individual cooling by changing the airflow and
some mechanical or electronics section modification, the TEC air cooling for car
36