10 REINFORCEMENT CALCULATION:

Provide T 32 @ 125 c/c E/W Top and Bottom of Footing


Provide T 25 @ 200 c/c Sides of Footing
Provide T 12 @ 600 c/c Triaxial Vertical
Provide T 12 @ 600 c/c Triaxial Horizontal

10.1 CHECK FOR WEIGHT OF REINFORCEMENT

As the foundation is designed as a block foundation, a minimum shrinkage reinforcement of 30kg/m 3 shall be provided

Weight of reinf. required(footing) = 11.7 x 9.00 x 2.00 x 30 = 6318 kg


Reinforcement provided :
Footing
Top 60 bars x ( 9.00 + 2.000 ) x 3.86 = 2547.60 kg
73 bars x ( 11.70 + 2.000 ) x 6.32 = 6320.63 kg
Bottom same as that in top = 8868.23 kg
Sides (horz) 2.00 bars x 20.70 x 3.86 = 159.80 kg
2.00 bars x 20.70 x 3.86 = 159.80 kg
Triaxial (Horz) 19 bars x 9.00 x 0.89 = 152.19 kg
14 bars x 11.7 x 0.89 = 145.78 kg
Triaxial (Ver) 38 bars x 2.00 x 0.89 = 67.64 kg
Total Reinforcement in Foundation = 18421.68 kg > 6318 kg
Hence O.K
10.2 REINFORCEMENT SKETCH:

T32 - 125 c/c E/W Top and Bottom

SECTIONAL PLAN

T25 - 200 c/c T.O.G

Triaxial 38Nos of T12 - 600 c/c


B.O.F

Triaxial 19Nos of T12 - 600 c/c Triaxial 14Nos of T12 - 600 c/c

SECTIONAL ELEVATION
REINFORCEMENT ARRANGEMENT
10.3 Minimum Rebar Check

The reinforcement provided is as per Cl. No. 7.12.2.1, ACI 318M-05 @ 0.2% gross area (Top & Bottom reinforcement

in long. direction) & Cl. No 4.4.1, ACI 351.3R - 45, the minimum reinforcement of 0.38% gross area (total reinforcement

@ 30 kg/m3 of conc.).