Meander 1051, 6825 MJ Arnhem P.O. Box 5185, 6802 ED Arnhem, The Netherlands
T +31 88 96 83000 F +31 88 96 83100
www.dekra-certification.com Company registration 09085396
TEST REPORT
Electromagnetic Compatibility (EMC)
Trademark EVBox
b
Operational Manager EMC
INDEX
page
General conditions............................................................................................................................................... 4
Uncertainty .......................................................................................................................................................... 4
Abbreviations....................................................................................................................................................... 5
In order to assure the traceability to other national and international laboratories, DEKRA has a calibration and
maintenance program for its measurement equipment.
DEKRA guarantees the reliability of the data presented in this report, which is the result of the measurements and
the tests performed to the item under test on the date and under the conditions stated in the report and it is based
on the knowledge and technical facilities available at DEKRA at the time of performance of the test.
DEKRA is liable to the client for the maintenance of the confidentiality of all information related to the item under
test and the results of the test.
The results presented in this Test Report apply only to the particular item under test established in this document.
IMPORTANT: No parts of this report may be reproduced or quoted out of context, in any form or by any means,
except in full, without the previous written permission of DEKRA.
GENERAL CONDITIONS
1. This report is only referred to the item that has undergone the test.
2. This report does not constitute or imply on its own an approval of the product by the Certification Bodies or
Competent Authorities.
3. This document is only valid if complete; no partial reproduction can be made without previous written
permission of DEKRA.
4. This test report cannot be used partially or in full for publicity and/or promotional purposes without previous
written permission of DEKRA.
UNCERTAINTY
For all measurements where guidance for the calculation of the instrumentation uncertainty of a measurement is
specified in EN 55016-4-2 (CISPR 16-4-2), EN/IEC 61000-4 series or a product standard, the measurement
instrumentation uncertainty has been calculated and applied in accordance with these standards.
Uncertainties have been calculated according to the DEKRA internal document PROD-P-EMC-M22. The reported
expanded uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a
level of confidence of approximately 95%. Refer to the Annex 1 for furter information.
ENVIRONMENTAL CONDITIONS
The climatic conditions during the tests are within the limits specified by the manufacturer for the operation of the
EUT and the test equipment. The climatic conditions during the tests were within the following limits:
Ambient temperature 15 °C – 35 °C
Relative Humidity air 30% - 60%
Atmospheric pressure 86 kPa – 106 kPa
If explicitly required in the basic standard or applied product / product family standard the climatic values are
recorded and documented separately in this test report.
Indicates that the listed condition, standard or equipment is applicable for this report/test/EUT.
Indicates that the listed condition, standard or equipment is not applicable for this report/test/EUT.
Decimal separator used in this report Comma (,) Point (.)
ABBREVIATIONS
For the purposes of the present document, the following abbreviations apply:
DOCUMENT HISTORY
The equipment under test (EUT) does meet the essential requirements of the stated standard(s)/test(s).
The functions of the internal “Electricity meter” unit were not part of this assessment.
1 GENERAL INFORMATION
The power input and output are directly connected in charge mode (EVSE using mechanical switching devices).
The equipment under test (EUT) is intended to be used in the following environment(s):
For the Equipment Under Test (EUT) the following classification is applicable.
All ITE equipment that satisfies Class A limits but not Class B limits. Such
equipment should not be restricted in its sale but the following warning shall be
included in the instruction for use.
Class A
Warning – This is a class A product. In a domestic environment this product may
cause interference in which case the user may be required to take adequate
measures.
Equipment intended primarily for use in the domestic environment and may include
Class B portable equipment, telecom terminal equipment powered by a telecom network
and personal computers and auxiliary connected equipment.
During the tests the following operating mode(s) has(have) been used.
Cable
Connected to /
Port name and description Specified Attached
Termination Shielded
length [m] during test
AC input power AC mains 3
AC output power Load 5
Supplemental information:
---
The EUT has been tested with the following auxiliary equipment / unit / software:
The following test setup / configuration / block diagram has been used during the tests:
3.1 Standards
The following deviation(s) was / were made from the published requirements of the listed standards:
“Radio-frequency Immunity electromagnetic field” test (EN 61000-4-3) has been performed at 3 V/m instead
of 1 V/m at frequency range 2,0-2,7 GHz.
Standard EN 61000-6-3
Limits
1) 1)
Frequency range [MHz] Limit: QP [dB(V) ] Limit: AV [dB(V) ] IF BW Detector(s)
2) 2)
0,15 - 0,50 66 – 56 56 - 46 9 KHz QP, CAV
0,50 - 5,0 56 46 9 KHz QP, CAV
5,0 - 30 60 50 9 KHz QP, CAV
1)
At the transition frequency, the lower limit applies.
2)
The limit decreases linearly with the logarithm of the frequency.
Performed measurements
The RF disturbance level was investigated at all operating modes modes listed
Operating mode(s) used
in section 2.1. respectively. The worst case results were reported.
Remark ---
Operating mode / voltage / frequency used during the test Mode 2 / 230 Vac / 50 Hz
120
100
80
Level in dBµV
60
40
20
0
150k 300 400 500 800 1M 2M 3M 4M 5M 6 8 10M 20M 30M
Frequency in Hz
Final_Result
Meas. Bandwi
Frequency QuasiPeak Average Limit Margin Corr.
Time dth Line PE Comment
(MHz) (dBµV) (dBµV) (dBµV) (dB) (dB)
(ms) (kHz)
0.418000 46.64 --- 57.49 10.85 1000.0 9.000 L2 GND 10.2
0.418000 --- 37.93 47.49 9.56 1000.0 9.000 L2 GND 10.2
0.458000 45.43 --- 56.73 11.30 1000.0 9.000 L3 GND 10.2
0.458000 --- 36.70 46.73 10.03 1000.0 9.000 L3 GND 10.2
0.596000 --- 45.22 46.00 0.78 1000.0 9.000 L3 GND 10.3
0.596000 52.33 --- 56.00 3.67 1000.0 9.000 L3 GND 10.3
0.704000 46.17 --- 56.00 9.83 1000.0 9.000 L1 GND 10.2
0.704000 --- 37.11 46.00 8.89 1000.0 9.000 L1 GND 10.2
0.798000 --- 35.92 46.00 10.08 1000.0 9.000 L3 GND 10.3
0.798000 48.47 --- 56.00 7.53 1000.0 9.000 L3 GND 10.3
1.192000 --- 37.41 46.00 8.59 1000.0 9.000 L2 GND 10.2
1.192000 46.53 --- 56.00 9.47 1000.0 9.000 L2 GND 10.2
1.788000 --- 38.06 46.00 7.94 1000.0 9.000 L1 GND 10.3
1.788000 43.62 --- 56.00 12.38 1000.0 9.000 L1 GND 10.3
2.396000 --- 31.84 46.00 14.16 1000.0 9.000 L1 GND 10.3
2.396000 41.04 --- 56.00 14.96 1000.0 9.000 L1 GND 10.3
3.174000 --- 35.43 46.00 10.57 1000.0 9.000 L2 GND 10.3
3.174000 42.27 --- 56.00 13.73 1000.0 9.000 L2 GND 10.3
13.564000 --- 59.57 50.00 -9.57 1000.0 9.000 L3 GND 10.9 1)
13.564000 77.47 --- 60.00 -17.47 1000.0 9.000 L3 GND 10.9
RFID module
13.692000 --- 20.22 50.00 29.78 1000.0 9.000 L3 GND 10.9
13.692000 36.98 --- 60.00 23.02 1000.0 9.000 L3 GND 10.9
21.554000 --- 33.39 50.00 16.61 1000.0 9.000 L3 GND 11.1
21.554000 43.60 --- 60.00 16.40 1000.0 9.000 L3 GND 11.1
1)
According to the EN 55011 standard Table 1 footnote b) no limits apply to the fundamental and all other frequency
components falling within the designated band of RF product(s)/unit(s).
Remark The given graph is the combination of max-hold function of each line.
Standard EN 61000-6-3
Basic standard(s) EN 55016-2-3
Test method Antenna method according to EN 55016-2-3 standard.
Supplementary information:
---
Limits
Frequency Limit: QP [dB(V/m)1)]
IF BW Detector
[MHz] @3 m. @5 m. @10 m.
30 - 230 40 36 30 120 KHz QP
230 - 1000 47 43 37 120 KHz QP
1)
At the transition frequency, the lower limit applies.
Performed measurements
Port under test Enclosure
Voltage – Mains [V] 230 VAC
Frequency – Mains [Hz] 50 Hz
The RF disturbance level was investigated at all operating modes modes listed in
Operating mode(s) used
section 2.1. respectively. The worst case results were reported.
Remark ---
Operating mode / voltage / frequency used during the test Mode 2 / 230 Vac / 50 Hz
Full Spectrum
80
70
60
Level in dBµV/m
50
40
30
20
10
0
30M 50 60 80 100M 200 300 400 500 800 1G
Frequency in Hz
Frequency QuasiPeak Limit Margin Meas. Time Bandwidth Height Azimuth Corr.
Pol
(MHz) (dBµV/m) (dBµV/m) (dB) (ms) (kHz) (cm) (deg) (dB)
32.190000 31.30 40.00 8.70 1000.0 120.000 119.0 V -48.0 11.3
68.010000 28.24 40.00 11.76 1000.0 120.000 150.0 V 19.0 9.4
80.580000 30.11 40.00 9.89 1000.0 120.000 133.0 V -42.0 9.0
98.100000 24.87 40.00 15.13 1000.0 120.000 400.0 H -11.0 12.3
199.980000 35.81 40.00 4.19 1000.0 120.000 163.0 H -2.0 12.6
205.740000 32.13 40.00 7.87 1000.0 120.000 169.0 H -13.0 13.0
298.350000 34.15 47.00 12.85 1000.0 120.000 196.0 V -7.0 15.1
Remark ---
Standard EN 61000-6-3
Limits
Performed measurements
Port under test Enclosure
Voltage – Mains [V] 230 VAC
Frequency – Mains [Hz] 50 Hz
Test method applied Absorber-lined OATS or SAC with measurement distance [m]: 3 m.
Absorber-lined OATS or SAC with measurement distance [m]: 1 m.
Test setup Equipment on a table of 80 cm height
Equipment on the floor (insulated from ground plane)
Other:
Refer to the Annex 3 for test setup photo(s).
The RF disturbance level was investigated at all operating modes modes listed in
Operating mode(s) used
section 2.1. respectively. The worst case results were reported.
Remark ---
Operating mode / voltage / frequency used during the test Mode 2 / 230 Vac / 50 Hz
Full Spectrum
100
90
80
70
Level in dBµV/m
60
50
40
30
20
10
0
1 1,5 2 2,5 3 3,5 4 4,5 5 5,5 6
Frequency in GHz
Final_Result
Meas.
Frequency MaxPeak Limit Margin Bandwidth Height Azimuth Corr.
Time Pol
(MHz) (dBµV/m) (dBµV/m) (dB) (kHz) (cm) (deg) (dB)
(ms)
1032.000000 34.52 70.00 35.48 1000.0 120.000 157.0 H 257.0 3.1
1872.000000 35.74 70.00 34.26 1000.0 120.000 135.0 H 74.0 5.9
4467.250000 37.46 74.00 36.54 1000.0 120.000 191.0 H 283.0 18.2
Remark ---
Standard EN 61000-6-3
Classification
Performed measurements
Port under test AC mains power input
Voltage – Mains [V] 230 VAC
Frequency – Mains [Hz] 50 Hz
Control principle used in Comply with the requirements of the Clause 6.1 (EN / IEC 61000-3-2).
the EUT Not comply with the requirements of the Clause 6.1 (EN / IEC 61000-3-2).
Operating mode / voltage / frequency used during the test Mode 2 / 230 Vac / 50 Hz
Remark ---
Operating mode / voltage / frequency used during the test Mode 2 / 230 Vac / 50 Hz
Remark ---
Operating mode / voltage / frequency used during the test Mode 2 / 230 Vac / 50 Hz
Remark ---
Standard EN 61000-6-3
Limits
PST (Short term flicker) 1 Not Applicable
PLT (Long term flicker) 0,65 Not Applicable
dC (Relative Voltage change) 3,3% Not Applicable
dMAX (Max. voltage change) 4% 6%
7% Not Applicable
Supplemental information:
---
Performed measurements
Reason for not performing Tests are not necessary because the EUT is unlikely to produce
the measurement(s) significant voltage fluctuations or flicker (clause 6.1).
Remark
Performance criterion A: The apparatus shall continue to operate as intended during and after the test. No
degradation of performance or loss of function is allowed below a performance level specified by the
manufacturer, when the apparatus is used as intended. The performance level may be replaced by a permissible
loss of performance lf the minimum performance level or the permissible performance loss is not specified by the
manufacturer either of these may be derived from the product description and documentation and what the user
may reasonably expect from the apparatus if used as intended.
Performance criterion B: The apparatus shall continue to operate as intended after the test. No degradation of
performance or loss of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended. The performance level may be replaced by a permissible loss of performance.
During the test, degradation of performance is however allowed. No change of actual operating state or stored
data is allowed. lf the minimum performance level or the permissible performance loss is not specified by the
manufacturer either of these may be derived from the product description and documentation and what the user
may reasonably expect from the apparatus if used as intended.
Performancec riterion C: Temporary loss of function is allowed, provided the function is self-recoverable or can be
restored by the operation of the controls.
Electrostatic discharge B
Radio-frequency electromagnetic fields A
Fast transients B
Surge transient B
Injected currents (radio-frequency common mode) A
Power frequency magnetic field immunity A
Voltage dips and short interruptions B, C
Not provided.
During the immunity tests the following functions of the EUT has/have been monitored/checked.
Monitored - Checked
Immunity test function(s)/parameter(s) during / Method
after the test
Electrostatic discharge
Radio-frequency electromagnetic fields
LEDs and lamps have been
Fast transients monitored/observed. After each test
Visual / Camera
Surge transient the functions of the EUT were
checked.
Injected currents (radio-frequency common mode)
Voltage dips and short interruptions
Supplementary information :
---
Electrostatic discharges (ESD) are the result of persons or objects that accumulate static electricity due to for
instance walking on synthetic carpets. The ESD can influence the operation of equipment or damage its
electronics, either by a direct discharge or indirectly by coupling or radiation. Both effects are simulated during the
tests.
Requirements
Standard EN 61000-6-2
Performed tests
Set-up Table-top Floor standing
Ambient temperature [°C] 22 Relative Humidity air [%] 53
During the test no loss of performance was observed. After the test the EUT
Observation(s) functioned as intended. No unacceptable loss of performance or data was
observed.
Supplementary information:
---
Supplementary information: RED & BLUE points show the discharge points.
During the test it is verified if the equipment under test (EUT) has sufficient immunity against radiated
electromagnetic fields. Industrial electromagnetic sources, walkie-talkies, radio transmitters, television transmitters
and telecommunication equipment including cellular telephones and other emitting devices can generate these
fields.
Requirements
Standard EN 61000-6-2
Performed tests
Test method EN 61000-4-3 EN 61000-4-20
Test set-up Equipment on the table (0,8 m height)
(see annex 3 for photo) Equipment standing on floor (0,05 – 0,15 m height)
During the test no loss of performance was observed. After the test the EUT
Observation(s) functioned as intended. No unacceptable loss of performance or data was
observed.
Supplementary information:
----
The EFT immunity test simulates disturbances by bursts of very short transients caused for example by switching
off loads such as an AC motor or bouncing relay contacts. The transients are likely to disturb electronics but less
likely to cause damage.
Requirements
Standard EN 61000-6-2
Performed tests
Voltage – Mains [V] 230 VAC
Frequency – Mains [Hz] 50 Hz
Operating mode(s) used Modes 1 and 3.
Test Set-up Equipment standing on floor at (0,1 ± 0,01) m above ground plane
(see annex 3 for photo) Equipment on the table (0,1 ± 0,01) m above ground plane
Artificial hand applied. Location refer to chapter 9.
Coupling Common mode Other:
During the test no loss of performance was observed. After the test the EUT
Observation(s) functioned as intended. No unacceptable loss of performance or data was
observed.
Supplementary information:
---
The surge transient immunity test simulates the surges that are caused by over-voltages due to indirect (induced)
lightning transients. The pulse is a slow transient with high-energy contents and due to its long duration may
cause damage to an unprotected EUT.
Requirements
Standard EN 61000-6-2
Performed tests
Voltage – Mains [V] 230 VAC
Frequency – Mains [Hz] 50 Hz
Operating mode(s) used Mode 1.
Repetition rate 60 secs. (for each test level and phase angle)
Number of pulses 5 pulses (at each polarity and phase angle)
Phase angle
Port under test Coupling Test level & Polarity Remark
[o]
Line 1 to Neutral ±0,5 / ±1 kV 0, 90, 180, 270 ---
AC mains input power Line 2 to Neutral ±0,5 / ±1 kV 0, 90, 180, 270 ---
Line 3 to Neutral ±0,5 / ±1 kV 0, 90, 180, 270 ---
Line 1 to Line 2 ±0,5 / ±1 kV 0, 90, 180, 270 ---
AC mains input power Line 1 to Line 3 ±0,5 / ±1 kV 0, 90, 180, 270 ---
Line 2 to Line 3 ±0,5 / ±1 kV 0, 90, 180, 270 ---
Line 1 to Earth ±0,5 / ±1 / ±2 kV 0, 90, 180, 270 ---
ACmains input power Line 2 to Earth ±0,5 / ±1 / ±2 kV 0, 90, 180, 270 ---
Line 3 to Earth ±0,5 / ±1 / ±2 kV 0, 90, 180, 270 ---
ACmains input power Neutral to Earth ±0,5 / ±1 / ±2 kV 0, 90, 180, 270 ---
During the test no loss of performance was observed. After the test the EUT
Observation(s) functioned as intended. No unacceptable loss of performance or data was
observed.
Supplementary information:The power input and output are directly connected in charge mode (EVSE using
mechanical switching devices).The test to the output port is not applicable.
During this test the immunity of the equipment for induced or conducted electromagnetic fields is checked. Fields
generated by radio and other transmitters cause RF voltages in long cables like the mains network. This test
reproduces these induced disturbing voltages by injecting them to the EUT via the cabling.
Requirements
Standard EN 61000-6-2
Port under test Test level, Uo Modulation Step size Dwell time
Performed tests
Frequency range Modulation Step size
Test method (applied)
(applied) (applied) (applied)
EN 61000-4-6 0,15 – 80 MHz 80% AM (1kHz) 1%
Test set-up Equipment standing on floor at (0,1 ± 0,01) m above ground plane.
(see annex 3 for photo) Equipment on the table (0,1 ± 0,01) m above ground plane.
Artificial hand applied. Location refer to Annex 3.
Test Level Dwell time
Port under test Injection method Remark
(applied (applied)
AC mains power input 10 V RF-Injection Clamp 2s ---
AC power output 10 V RF-Injection Clamp 2s ---
External grounding cable 10 V CDN-M1 2s ---
During the test no loss of performance was observed. After the test the EUT
Observation(s) functioned as intended. No unacceptable loss of performance or data was
observed.
Supplementary information:
---
The purpose of the test is to verify the immunity of the equipment against voltage dips and voltage interruptions. It
helps to ensure that the equipment functions properly (as expected and safely) with power supply fluctuations.
Voltage dips and interruptions are caused by faults in the LV, MV, HV networks (short-circuit or ground faults).
Requirements
Standard EN 61000-6-2
Performed tests
Test level Duration [cycles] Repetion rate Number of Phase angle
UNOM [VAC] Terminal
[% UNOM] 50 Hz 60 Hz [s] dips per test [o]
L1-N, L2-N,
230 0 1 --- 10 3 0, 180
L3-N
L1-N, L2-N,
230 40 10 --- 10 3 0, 180
L3-N
L1-N, L2-N,
230 70 25 --- 10 3 0, 180
L3-N
L1-N, L2-N,
230 0 250 --- 10 3 0, 180
L3-N
L1-L2, L1-
400 0 1 --- 10 3 0, 180
L3, L1-L3
L1-L2, L1-
400 40 10 --- 10 3 0, 180
L3, L1-L3
L1-L2, L1-
400 70 25 --- 10 3 0, 180
L3, L1-L3
L1-L2, L1-
400 0 250 --- 10 3 0, 180
L3, L1-L3
The table(s) below show(s) measurment uncertainties of the EMC test set-ups. The reported expanded
uncertainties are based on a standard uncertainty multiplied by a coverage factor of k=2, providing a level of
confidence of approximately 95%.
Conducted Emissions
Equipment Manufacturer Model DEKRA ID
EMI Test Receiver Rohde & Schwarz ESHS 10 117863
Artificial Mains Network Rohde & Schwarz ESH2-Z5 128201
Pulse Limiter Rohde & Schwarz ESH3-Z2 116978
Test Software Rohde & Schwarz EMC32 V.10.20.01 ---
ESD immunity
Equipment Manufacturer Model DEKRA ID
ESD generator Noise Ken ESS 2002 118824
Surge Immunity
Conducted RF Immunity
ESD Immunity