Technical Specification
Description LC - 1046 LC - 2046 LC - 445
Dimension 96 X 96 X 50 mm 72 X 72 X 60 mm 48 X 48 X 90 mm
Panel Cutout 92 X 92 mm 68 X 68 mm 44 X 44 mm
Upper: 6 digit, 0.56’’, Upper: 6 digit, 0.4’’, Upper: 5 digit, 0.3’’,
7 segment, Red LED 7 segment, Red LED 7 segment, Red LED
Display
Lower: 4 digit, 0.4’’, Lower: 4 digit, 0.3’’,
7 segment, Green LED 7 segment, Green LED
Output 1 relay, 1 C/O, 230V AC, 5A 1 relay, 2 C/O, 230V AC, 5A
Supply 230V AC, 50 Hz 110V to 250V AC, 50 Hz smps
Sensor Proximity PNP / NPN Proximity NPN/PNP (Factory Set)
Memory Power Failure Facility
Principle
1). The proximity switch give pulse to counter everytime the metal on the roller is sensed.
2). Length of Material ( in meter ) for one revolution = 3.14 X Diameter (mm)
3). Total length = { 3.14 X Diameter (mm) X Number of Revolutions } / 1000
4). Total Meters/Minute = { 3.14 X Diameter (mm) X RPM } / 1000
Note
1). When pulse comes from sensor, upper display indicates increment in ‘Total Length’ in Meter.
Lower Display indicates ‘Speed’ in Meter/Min.
2). For Manual Mode, set time = 00.0 sec & For Auto Reset Mode, set time = 00.1 to 99.9 sec.
3). In RUN mode, if we press SHIFT key then upper display shows Batch Count.
4). When Total Length = Set Length, relay-1 energise. Relay-1 remains ON for Auto Reset Time.
Relay turns off after completion of time. If time is set at 00.0 sec. then relay remains ON until
RST key is pressed.
5). If there is a power failure the last reading is stored in the memory and Counter starts resume
counting from the last stored value, when power ON.
6). To restart Totalizing or to Reset press RST key. Upper display will show 00000.0 and the
counting will restart.
Page - 1 www.multispanindia.com
Front Panel Description
During RUN MODE: shows Total Length in Meters Length Counter LC-1046

1 2 3 4 5. 6
During RUN MODE: on pressing SHIFT key shows Batch Count
During Length Set Mode: shows Set Length in Meters
During Diameter Set Mode: shows Diameter in Milimeter METERS

During Time Set Mode: shows Set Time in Seconds


R1
During RUN MODE: shows Speed in Meters/min.
During RUN MODE: on pressing SHIFT key shows B A T C 1 2 3. 4 R2
During Length Set Mode: shows S E T MT/MIN.
During Diameter Set Mode: shows D I A BATCH
During Time Set Mode: shows T I M E SET
RSET
ENT

RESET key
UP key
SHIFT key

Procedure to Program the Length Counter SET/ENTER key

1 2 3 4 5. 6 Total Length in Mtr.


1 2 3. 4 Speed in Mtr/Min.

SET
press ENT key for 2 sec
set LENGTH
9 9 9 9 9. 9 Set Length value by pressing & key
s e t
: SHIFT key to go to next digit for changing
SET
value of the digit.
press ENT key for 4 sec : UP key increases value of individual digit
Range: 00000.1 to 99999.9 mtr

set DIAMETER
9 9 9 9. 9 9 Set Diameter value by pressing & key
D I A
press SET
ENT key for 10 sec : SHIFT key to go to next digit for changing
value of the digit.
: UP key increases value of individual digit
Range: 0000.01 to 9999.99 mm

set TIME
9 9. 9 Set Diameter value by pressing & key
T I M E
: SHIFT key to go to next digit for changing
value of the digit.
: UP key increases value of individual digit
Range: 00.1 to 99.9 sec.

Page - 2 www.multispanindia.com
CONNECTION TERMINAL DIAGRAM

GND I/P2 I/P1 +Ve


20 19 18 17 16 15 14 13 12 11 1 8

230V AC

110-270V AC/DC
SUPPLY
15 16 17 9 L

SUPPLY
2 NC
+VE I/P1 I/P2 GND RESET N
NPN PROXI:- Short Pins 20 & 19 3 10 NO
N
Proxi Connection to 19,18 & 17
4 11

RELAY
PNP PROXI:- Short Pins 18 & 17 +VE
Proxi Connection to 20,19 & 18 C

NPN PROXY
SUPPLY
230V AC RELAY I/P
L N E NC C NO 5 12 NO

RELAY
GND
6 13 NC
1 2 3 4 5 6 7 8 9 10 18 19 20
RESET 7 14

LC - 1046 LC - 2046 LC - 445

PNP
proximity switch
PNP proximity switch connection for model LC - 1046 & LC - 2046
GND
+VE

I/P

GND
I/P2
I/P1
+VE

SHORT

NPN
proximity switch NPN proximity switch connection for model LC - 1046 & LC - 2046
GND
+VE

I/P

GND
I/P2
I/P1
+VE

SHORT

NPN
proximity switch NPN proximity switch connection for model LC - 445