P Fijaci de la estructu *
P Pressi del refuerzo ( kPa 0 0 0
P Pressi del refuerzo ( mmHg 0 0 0
Comentios
Adjust only variation between cylinders; adjust governor according to governor specifications.
CAT Denominación Unidad Valor de ajuste mín. máx. Valores reales OT
P Punto de ajuste D
P Posici de la estructu 10.3++
P Velocidad de la bomba r/min 100 100 100
S Cantidad mia de inyec mm3/st. 90 85 95
P Fijaci de la palanca *
P Pressi del refuerzo ( kPa 38.7 38.7
P Pressi del refuerzo ( mmHg 290 290
P Lite de la estructura *
CAT Denominación Unidad Valor de ajuste mín. máx. Valores reales OT
P Punto de ajuste E
P Posici de la estructu 9.4
P Velocidad de la bomba r/min 100 100 100
S Cantidad mia de inyec mm3/st. 50 45 55
P Fijaci de la palanca *
P Pressi del refuerzo ( kPa 0 0 0
P Pressi del refuerzo ( mmHg 0 0 0
2.3 Ajuste del regulador (g
Nombre
C = Valor de comprobación)
OT = Tolerancia exterior (Se ajusta X)
101609-3601 Equipo de inyección de combustible diesel de valores de prueba ZEXEL 27/05/19 09:25:13 Page 4
h=2.7mm Adjusting procedure for load plunger equipped pump with RSV (cam lock) governor (see service i
c=5deg30min+-30min nformation S.I. 434 for details).
At cam lift h+-0.01, set the camshaft c deg from the * mark in accordance with the timing adjustm
ent procedure.
2. Align the flyweight's timing tooth position and the lock pin groove and then fully tighten the flyw
eight to the camshaft. Then, remove the lock pin.
3. Adjust the maximum variation between cylinders and injection quantity.
4. Adjust using the pre-stroke adjusting shim so that the pre-stroke value is the value for 4/4 load
(standard point A).
5. After adjusting the pre-stroke, reconfirm that the injection quantity and the maximum variation b
etween cylinders are as specified.
6. At delivery, again fix the flyweight using the lock pin.
C = Valor de comprobación)
OT = Tolerancia exterior (Se ajusta X)
101609-3601 Equipo de inyección de combustible diesel de valores de prueba ZEXEL 27/05/19 09:25:13 Page 5
C = Valor de comprobación)
OT = Tolerancia exterior (Se ajusta X)