CON port, AUX port, corresponding to the line con and line aux; usually there is only
con port for one network equipment, and one aux port at most, or even not.
telnet / rlogin are corresponding line vty; because it is the virtual connectivity, multiple
vty can be coexisted, usually configuration commands≤ 64.
Switch_config#aaa authentication login default line Set the default login as LINE.
Switch_config#line vty 0 4
Enter the VTY mode 0-4 line and limit login 5 lines at the same time.
Switch_config_line#password ktcatv Set 0-4 line password as KTCATV.
Switch_config#service password-encryption Use MD5 encrypted password.
Use “show running-config” command to see the line certification.
Configuration command
Switch_config#vlan 2125
Switch_config_vlan2125#interface vlan 2125
Switch_config_v2125#ip address 170.30.12.2 255.255.252.0
Switch_config#ip default-gateway 170.30.12.1
Use show running-config command to check IP, manage VLAN and default gateway.
Remark: PTC04 can configure only one IP address, as for it’s the 2-layer product. If
re-configure management VLAN and IP, you must delete the former IP address and
enter new VLAN IP address.
Use show running-config command to check whether all ports are open.
Configuration command
Switch_config#interface ePON 0/1
Switch_config_epon0/1#switchport mode trunk
Switch_config_epon0/1#switchport trunk vlan-allowed 2125,2240-2244
Use show running-config command to check the configuration of No.1 PON port