Sunteți pe pagina 1din 52

Tadiran Lithium Batteries

Product Data
Catalogue
Customized battery packs
The design and assembly
of battery packs require
special skills, expertise and
experience. Therefore it is not
recommended that the end
user attempt to self-assemble
battery packs. It is prefer-
able that any battery using
lithium cells be fabricated by
Tadiran to ensure proper bat-
tery design and construction
(see figure 1). A full battery
assembly service is available
from Tadiran who can be con-
tacted for further information.
If for any reason, this is not
possible, Tadiran can review
the pack design in confidence
to ensure that the design is
safe (in assembly and use) Figure 1: Upon request, Tadiran
and capable of meeting stated designs, tests, and manufactures
PDC19Eng

performance requirements. customized battery packs.

Any values given here are for informational purposes only. They also depend on actual 2 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Overview Product Line
Page Contents
4 About Tadiran
5 Lithium Thionyl Chloride (LTC) Batteries
Model Terminations Catalogue number1) Size Nominal Nominal Nominal Max. cont. dis- Temperature Dimensions
voltage capacity current charge current range (mm)
SL-300 series: for standard use and stand-by
6 SL-350 /S /T /P /PR /PT 11 1 0350x 00 1/2AA 3.6 V 1.2 Ah 0.6 mA 6 mA −55 ... +85 °C Ø 14.5 x 25
7 SL-361 /S /T /P /PR /PT 11 1 0361x 00 2 ⁄3AA 3.6 V 1.6 Ah 1 mA 10 mA −55 ... +85 °C Ø 14.5 x 33
8 SL-360 /S /T /P /PR /PT 11 1 0360x 00 AA 3.6 V 2.4 Ah 2 mA 20 mA −55 ... +85 °C Ø 14.5 x 50
SL-500 series: for extended temperature range
9 SL-550 /S /T /P /PR /PT 11 1 0550x 00 1/2AA 3.6 V 0.9 Ah 0.6 mA 50 mA −55 ... +130 °C Ø 14.5 x 25
10 SL-561 /S /T /P /PR /PT 11 1 0561x 00 2 ⁄3AA 3.6 V 1.1 Ah 1 mA 75 mA −55 ... +130 °C Ø 14.5 x 33
11 SL-560 /S /T /P /PR /PT 11 1 0560x 00 AA 3.6 V 1.8 Ah 2 mA 100 mA −55 ... +130 °C Ø 14.5 x 50
SL-700 / SL-2700 series: for enhanced start
12 SL-750 /S /T /P /PR /PT 11 1 0750x 00 1/2AA 3.6 V 1.1 Ah 1 mA 50 mA −55 ... +85 °C Ø 14.5 x 25
13 SL-761 /S /T /P /PR /PT 11 1 0761x 00 2 ⁄3AA 3.6 V 1.5 Ah 1.3 mA 75 mA −55 ... +85 °C Ø 14.5 x 33
14 SL-760 /S /T /P /PR /PT 11 1 0760x 00 AA 3.6 V 2.2 Ah 2 mA 100 mA −55 ... +85 °C Ø 14.5 x 50
15 SL-2770 /S /T /P 11 2 1770x 00 C 3.6 V 8.5 Ah 3 mA 230 mA −55 ... +85 °C Ø 26 x 50
16 SL-2780 /S /T /P 11 2 1780x 00 D 3.6 V 19 Ah 4 mA 340 mA −55 ... +85 °C Ø 33 x 60
17 SL-2790 /S /T 11 2 1790x 00 DD 3.6 V 35 Ah 10 mA 450 mA −55 ... +85 °C Ø 33 x 123
18 TL-2450 /P (with insolation) 11 1 13763 02 1 ⁄10
C 3.6 V 0.55 Ah 0.5 mA 5 mA −55 ... +85 °C Ø 24 x 5.6
TL-2450 /P (without insolation) 11 1 13763 22 1 ⁄10
C 3.6 V 0.55 Ah 0.5 mA 5 mA −55 ... +85 °C Ø 24 x 5.6
SL-800 / SL-2800 series: XOL for extended operating life
19 SL-889 Solder pins 11 1 18894 00 1 ⁄10D 3.6 V 1 Ah 0.5 mA 10 mA −55 ... +85 °C Ø 33 x 6
20 SL-886 Solder pins 11 1 18864 00 1 ⁄6D 3.6 V 1.5 Ah 0.5 mA 10 mA −55 ... +85 °C Ø 33 x 10
21 SL-850 /S /T /P /PR /PT 11 1 0850x 00 1/2AA 3.6 V 1.2 Ah 0.5 mA 20 mA −55 ... +85 °C Ø 14.5 x 25
22 SL-861 /S /T /P /PR /PT 11 1 0861x 00 2 ⁄3AA 3.6 V 1.6 Ah 0.5 mA 30 mA −55 ... +85 °C Ø 14.5 x 33
23 SL-860 /S /T /P /PR /PT 11 1 0860x 00 AA 3.6 V 2.4 Ah 1 mA 60 mA −55 ... +85 °C Ø 14.5 x 50
24 SL-2870 /S /T /P 11 2 1870x 00 C 3.6 V 8.5 Ah 3 mA 75 mA −55 ... +85 °C Ø 26 x 50
25 SL-2880 /S /T /P 11 2 1880x 00 D 3.6 V 19 Ah 4 mA 100 mA −55 ... +85 °C Ø 33 x 60
26 PulsesPlus  TM Batteries
Model Termination Catalogue number Configuration Nominal Nominal Max. pulse Dimensions
Primary cell HLC voltage capacity current2) (mm)
27 TLP-91111/A/SM Flying leads 17 91111 101 AA 1550 3.6 V 2.40 Ah 3A 55 x 32 x 16
28 TLP-91311/A/SM Pressure contacts 17 91311 101 AA 1520 3.6 V 2.40 Ah 1A Ø 16.5 x 75
28 TLP-91311/A/ST Solder tags 17 91311 102 AA 1520 3.6 V 2.40 Ah 1A Ø 16.5 x 75
29 TLP-92111/A/SM Flying leads 17 92111 101 C 1550 3.6 V 8.50 Ah 3A 55 x 44 x 28
30 TLP-92311/A/SM Flying leads 17 92311 101 C 1520 3.6 V 8.50 Ah 1A Ø 29 x 67
31 TLP-93111/A/SM Flying leads 17 93111 101 D 1550 3.6 V 19.0 Ah 3A 64 x 50 x 35
32 TLP-93311/A/SM Flying leads 17 93311 101 D 1520 3.6 V 19.0 Ah 1A Ø 34 x 78
33 TLP-96111/A/SM Flying leads 17 96111 101 1/2AA 1550 3.6 V 1.2 Ah 3A 55 x 32 x 16
34 TLP-96311/A/SM Pressure contacts 17 96311 101 1/2AA 1520 3.6 V 1.2 Ah 1A Ø 16.5 x 50
34 TLP-96311/A/ST Solder tags 17 96311 102 1/2AA 1520 3.6 V 1.2 Ah 1A Ø 16.5 x 50
35 TLP-97111/A/SM Flying leads 17 97111 101 2 ⁄3AA 1550 3.6 V 1.6 Ah 3A 55 x 32 x 16
36 TLP-97311/A/SM Pressure contacts 17 97311 101 2 ⁄3AA 1520 3.6 V 1.6 Ah 1A Ø 16.5 x 58
36 TLP-97311/A/ST Solder tags 17 97311 102 2 ⁄3AA 1520 3.6 V 1.6 Ah 1A Ø 16.5 x 58
37 Hybrid Layer Capacitors (HLC) for use in PulsesPlus TM Batteries
Model Maximum Maximum Max. cont. Max. pulse Maximum Maximum Discharge Cell Dimensions
charge charging discharge discharge capacity capacity end voltage impedance (mm)
voltage current current current (3.67 V) (3.9 V)
38 HLC-1020 3.95 V 8 mA 0.25 A 0.75 A 12.5 mAh 20 mAh 2.5 V ≤ 400 mΩ Ø 10 x 20
38 HLC-1020L 3.95 V 6 mA 0.15 A 0.5 A 8 mAh 12.5 mAh 2.5 V ≤ 600 mΩ Ø 10 x 20
39 HLC-1520A 3.95 V 25 mA 0.5 A 2A 39 mAh 58 mAh 2.5 V ≤ 250 mΩ Ø 15 x 20
40 HLC-1530A 3.95 V 50 mA 0.75 A 3A 70 mAh 105 mAh 2.5 V ≤ 140 mΩ Ø 15 x 27
41 HLC-1550A 3.95 V 100 mA 2A 5A 155 mAh 236 mAh 2.5 V ≤ 100 mΩ Ø 15 x 50
42 Tadiran Lithium Metal Oxide (TLM) Batteries
Model Nominal Max. cont. dis- Max. pulse dis- Maximum End Cell Capacity Dimensions
voltage charge current charge current capacity voltage impedance retention3) (mm)
43 TLM-1520HPM 4.0 V 1.75 A 3.75 A 125 mAh 2.8 V ≤ 100 mΩ 89 % Ø 15 x 20
44 TLM-1530HPM 4.0 V 3.2 A 6.8 A 225 mAh 2.8 V ≤ 100 mΩ 89 % Ø 15 x 27
45 TLM-1550HPM 4.0 V 7A 15 A 500 mAh 2.8 V ≤ 100 mΩ 89 % Ø 15 x 50
46 Tadiran Lithium Ion (TLI) Batteries – RECHARGEABLE
Model Max. charge Max. charging Max. cont. dis- Max. pulse dis- Maximum End Cell Dimensions
voltage current charge current charge current capacity voltage impedance (mm)
47 TLI-1020A 4.1 V 8 mA 0.16 A 0.4 A 25 mAh 2.5 V ≤ 600 mΩ Ø 10 x 20
48 TLI-1520A 4.1 V 25 mA 0.5 A 1.25 A 90 mAh 2.5 V ≤ 250 mΩ Ø 15 x 20
49 TLI-1530A 4.1 V 50 mA 1A 2.5 A 150 mAh 2.5 V ≤ 175 mΩ Ø 15 x 27
50 TLI-1550A 4.1 V 100 mA 2A 5A 330 mAh 2.5 V ≤ 100 mΩ Ø 15 x 50
51 Safety and Transport Regulations
PDC19Eng

1) complete catalogue number depends on termination; see product page 2) pulse duration 1 s to 3 V 3) after 10 years of storage at RT
Any values given here are for informational purposes only. They also depend on actual 3 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
About Tadiran
Tadiran Batteries GmbH The company is a leader in Customer benefits Environment
Tadiran Batteries GmbH is the development of lithium Tadiran has focused its on- The European Battery Direc-
the leading manufacturer of batteries for industrial use. going efforts on promoting tive 2006/66/EC restricts
primary (non rechargeable) Its Lithium Thionyl Chloride the understanding and further the use of certain hazardous
lithium batteries in Europe. (LTC) technology is well estab- development of lithium bat- substances in batteries and
lished for more than 35 years. teries. This determination of- establishes rules for the col-
The company was founded Tadiran LTC batteries are fers to the customer a number lection, treatment, recycling
as a Joint Venture between suitable where a 3.6 Volt high of decisive benefits such as: and disposal of waste bat-
Tadiran and Sonnenschein energy primary battery is re-

Access to over 50 years of teries and accumulators. It


in 1984 and has very quired for up to 25 years and experience in research and is transposed individually in
success­fully served the market – more stand alone operation. development, production each EU member state.
first under the name of and marketing
Sonnenschein Lithium The PulsesPlus  TM technology,

Adaptability and reliability The following information is


and since 2006 as Tadiran providing high current pulses in meeting rapidly evolving important for end users of
Batteries – for more than in combination with high customer needs batteries:
35 years. energy, plays a significant

Detailed technical support


role especially for long dis- in terms of design and ap- Batteries are marked with
Together with its parent com- tance communication (e.g. plication – before, during the crossed-out wheeled bin
pany Tadiran Batteries Ltd., GSM) modules. and after the purchase symbol.
the company is continuously

Highly qualified experts


improving its performance The TLM technology has been available for support
with regard to products, developed for applications re- on short notice The symbol reminds end users
highest quality and customer quiring high power discharge

Customized production that batteries must not be


service. after a long storage time, e.g. of single- and multi-cell disposed as municipal waste,
as a back up battery for emer- batteries to meet specific but collected separately. Used
Tadiran Batteries Ltd. is fully gency call devices in automo- requirements batteries can be returned at
owned by Saft Group. tive telematic systems.

Reliable delivery, secured the point of sale at no charge.


by contractual agreements
The main focus of the com- The RECHARGEABLE TLI and second sourcing. A Technical Notice is available
pany is to achieve a maximum series is specifically designed upon request with details on
customer satisfaction. Thus for long-term use in harsh For successful use of a the disposal service offered by
the guide line is to be the environments and repre- battery, the co-operation Tadiran.
best in design-in, in full tech- sents an important break- between the supplier and the
nical support and logistics. through in lithium-ion battery customer must commence at
technology. the earliest possible point:
The company is committed to at times it is simply more
the world class philosophy. economical to design a circuit
The management system is for the characteristics of the
certified to ISO 9001 (Qual- best suitable energy supply,
ity) and – since 1999 – to ISO rather than having to forgo its
14001 (Environment). advantages because it is too
late for changes.
Tadiran Batteries GmbH em-
ploys approx. 120 people and
has its production facilities in
Büdingen, Germany.
PDC19Eng

Any values given here are for informational purposes only. They also depend on actual 4 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Lithium Thionyl Chloride (LTC) Batteries

Introduction
The Lithium Thionyl Features and
Positive terminal
Chloride (LTC) battery attributes
Plastic cover
The Tadiran lithium thionyl of the various series the start of discharge at
Welding seam
chloride inorganic electrolyte SL-300 series medium current levels
battery is a power source that Cell cover Keywords: standard use and

Intermittent discharge at
is suited to the requirements Glass-to-metal seal stand-by medium current levels
of the new generation in Insulator

Excellent shelf life

Higher voltage under


microelectronics. For example, Current collector (10 years) pulse load even with low
CMOS memories as well as Lithium anode

Extremely low background currents


utility meters require a light- Cathode self-discharge (1 %

Improved voltage delay


weight power source to pro- Separator or less per year) behaviour at ambient and
vide a safe and reliable per- Insulating sleeve

Suited for long-term elevated temperatures


formance over a wide range of Cell can use with low current

Fast voltage recovery


environmental conditions, for Negative terminal

For operation at low current after long term storage


long periods of time. levels with long stands

Higher discharge rate


Figure 1: Cross sectional view of a ½AA size cell (bobbin-design)

Intermittent discharge
The Tadiran lithium battery Safe design The Teflon™-bonded carbon with medium current level SL-800/2800 series (XOL)
is a component that can be The battery’s design has a cathode serves as a catalyst provided the average Keywords: for eXtended
permanently connected to a major influence on its safety for cathodic reduction. is not below the active operation life
circuit and, in many cases, will characteristics (see figure 1). current level (2 µA / cm²

More capacity
last the entire lifetime of the The generally accepted reaction anode surface area)

Extra low self discharge


equipment. In the bobbin version, the mechanisms are as follows:

Temperature range from

Extra low passivation


cathode is cylindrical in

Anodic reaction: −55 °C to +85 °C during long term use


Battery characteristics shape. The anode is swaged 4 Li → 4 Li+ + 4 e−
The major advantages of the against the inner wall of

Cathodic reaction: SL-500 series


Tadiran lithium battery are: the battery case. This offers 2 SOCl2 + 4 e− → Keywords: extended tempera-
several advantages in terms SO2 + S + 4 Cl− ture range
High cell voltage of safety. In the event of an

Overall reaction:

Extension of temperature
The battery has a nominal unintentional short-circuit, 4 Li + 2 SOCl2 → range up to +130 °C
voltage of 3.6 Volts, which is the discharge currents do S + 4 LiCl + SO2

Somewhat smaller capacity


considerably higher than any not become very strong. The

Otherwise like the


other commercially available heat generated, primarily at Most of the sulphur dioxide SL-700 series
primary cell. the contact surface between generated during discharge
the anode and cathode, can dissolves in the electrolyte, SL-700/
Wide temperature range easily be channelled to the preventing pressure build-up SL-2700 (iXtra) series
The batteries are capable outside. This design leads to within the battery. Keywords: for enhanced start/
of operating in a wide tem- a safe battery that needs no for fast voltage recovery
perature range normally from additional rupture vent. Long-term behaviour

Major improvement of
−55 °C to +85 °C. One series, The long shelf life of the voltage delay (TMV) at
however, has an extended In the flat battery versions, Tadiran lithium batteries is a
temperature range of up to the anode is pressed onto the result of the fact that a thin
+130 °C. bottom of the case, and the protective layer of LiCl forms 4.0
cathode is disk-shaped. Flat on the anode as soon as the 3.5
1
High energy density batteries are wider than they lithium first comes into con- 2
The electrochemical system are high. They are just as safe tact with the electrolyte. This 3.0
3
offers the highest energy den- as the bobbin type batteries. layer prevents further reaction 2.5
Voltage / V

sity of any available primary or loss of capacity on stand. 4


battery: up to ~650 Wh / kg Hermetically sealed case The problem of anode cor- 2.0
and ~1280 Wh / dm3 (see The hermetically sealed case rosion, as occurs in aqueous 1.5 5
figure 2). is essential for the long shelf systems, is thus eliminated. 6
life and inherent safety of the 1.0
Superior shelf life devices in which the batteries On the other hand, the protec- 0.5
and reliability are used. The cover is welded tive layer on the anode may
The Tadiran lithium battery has to the can. A glass-to-metal cause a delay in the voltage 0.0
0 100 200 300 400
an outstandingly long shelf life. seal is used to insulate the build-up if relatively high Ah / dm3
Tests have shown that storage positive terminal. loads are applied, or after
for ten years at room tempera- extended storage at elevated Figure 2:
ture results in a capacity loss of The chemical reaction temperatures. This voltage Comparison of different battery systems. The curves represent typical
less than 1 % per year. The battery consists of a lith- delay is not experienced at best values of commercial cylindrical cells when discharged at +25 °C
ium (Li) anode, a carbon (C) all in microampere applica- at the 1000 hour rate. The area under the curves corresponds to the
Tadiran lithium batteries are cathode, and a non-aqueous tions, such as in typical CMOS energy density listed below.
also extremely reliable. Fail- electrolyte (a solution of lith- circuits. 1 Li/SOCl2 1280 Wh / dm3
2 Li/SO2 430 Wh / dm3
ure rates in memory back-up ium tetra-chloroaluminate in
3 Li/CFx 550 Wh / dm3
applications were found to be thionyl chloride). This solution
4 Li/MnO2 580 Wh / dm3
below 200 fit (fit: Failures in performs a dual task: as the 5 Li/FeS2 450 Wh / dm3
PDC19Eng

Time. 1 fit = 1 failure in 109 electrolyte for ion transport, 6 Alkaline 280 Wh / dm3
component hours). and as an active depolarizer.

Any values given here are for informational purposes only. They also depend on actual 5 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-350 Size: ½AA ›› Standard use and stand-by

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 1.2 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 0.6 mA
2.0
Max. continuous discharge current 6 mA 1: 560 Ω ~6 mA 0.90 Ah
1.5 2: 1.8 kΩ ~2 mA 1.10 Ah
Anode surface area 6 cm2 3: 5.6 kΩ ~0.6 mA 1.20 Ah
Lithium content 0.35 g 1.0 4: 18 kΩ ~0.2 mA 1.15 Ah
5: 56 kΩ ~0.06 mA 1.05 Ah
Weight 9.6 g 0.5 6: 180 kΩ ~0.02 mA 0.95 Ah
7: 560 kΩ ~0.006 mA 0.85 Ah
Volume 4 cm3
0.0
Temperature range −55 °C ... +85 °C 0.1 1 10 102 103 104 105
Time / h

Available Capacity
1.2
4
1.0 3
Capacity to 2 Volts / Ah 2
SL-350/S SL-350/T 0.8 5
1
+0.2
Ø 4.2 −0.3
0.6
1: +72 °C
0.4
0.7±0.3

2: +55 °C
3: +25 °C
0.2 4: 0 °C
5: −30 °C
25.2–1.2

0.0
7±0.5 0.01 0.1 1 10 100 1000
3.17 Current / mA

0.15 thick
Operating Voltage
Ø 14.7 –1.2
SL-350/P 3.8
3.6
Ø 0.8
Ø 0.8

5
4
3.4
3
3.2
Voltage / V

2
3.0
45 45 2.8 1 1: 6 mA
2.6 2: 2 mA
3: 0.6 mA
2.4 4: 0.2 mA
SL-350/PR SL-350/PT 5: 0.02 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
4+0.5

4+0.5
3.5

3.5

1–0.1 1–0.1 10.16


0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-350/S Standard 11 1 03501 00 WARNING:
SL-350/T Tags 11 1 03502 00 Fire, explosion, and
severe burn hazard. Do not
SL-350/P Pins 11 1 03503 00
recharge, disassemble, heat
PDC19Eng

SL-350/PR Pins radial 11 1 03506 00 above 100 °C, incinerate, or


SL-350/PT Polarized tags 11 1 03508 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 6 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-361 Size: 2⁄3AA ›› Standard use and stand-by

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 1.6 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 1 mA
2.0 1: 330 Ω ~10 mA
Max. continuous discharge current 10 mA 1.00 Ah
2: 1.0 kΩ ~3 mA 1.35 Ah
Anode surface area 9 cm2 1.5
3: 3.3 kΩ ~1 mA 1.60 Ah
1.0 4: 10 kΩ ~0.3 mA 1.60 Ah
Lithium content 0.5 g 5: 33 kΩ ~0.1 mA 1.50 Ah
Weight 12.5 g 0.5 6: 100 kΩ ~0.03 mA 1.35 Ah
7: 330 kΩ ~0.01 mA 1.10 Ah
Volume 5.2 cm3
0.0
Temperature range −55 °C ... +85 °C 0.1 1 10 102 103 104 105
Time / h

Available Capacity
1.6
5
1.4 4
3

Capacity to 2 Volts / Ah
SL-361/S SL-361/T 1.2
2
+0.2 1.0 1
Ø 4.2 −0.3
0.8
0.6 1: +72 °C

+
0.7±0.3

2: +55 °C
0.4 3: +25 °C
4: 0 °C
0.2 5: −30 °C

7 ±0.5 0.0
0.01 0.1 1 10 100 1000
33.5−1.5

3.17 Current / mA
0.15 thick
Operating Voltage
SL-361/P 3.8

Ø 14.7−1.2 3.6
Ø 0.8

Ø 0.8

6
5
3.4 4
3.2 3
Voltage / V

3.0 2
45 45 2.8 1: 10 mA
1 2: 3 mA
2.6 3: 1 mA
4: 0.3 mA
2.4 5: 0.1 mA
SL-361/PR SL-361/PT 6: 0.01 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
4+0.5

4+0.5
3.5

3.5

1−0.1 1−0.1 10.16

0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-361/S Standard 11 1 03611 00 WARNING:
SL-361/T Tags 11 1 03612 00 Fire, explosion, and
severe burn hazard. Do not
SL-361/P Pins 11 1 03613 00
recharge, disassemble, heat
PDC19Eng

SL-361/PR Pins radial 11 1 03616 00 above 100 °C, incinerate, or


SL-361/PT Polarized tags 11 1 03618 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 7 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-360 Size: AA ›› Standard use and stand-by

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 2.4 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 2 mA
2.0 1: 180 Ω ~20 mA
Max. continuous discharge current 20 mA 1.5 Ah
2: 560 Ω ~6 mA 2.1 Ah
Anode surface area 14 cm2 1.5
3: 1.8 kΩ ~2 mA 2.4 Ah
1.0 4: 5.6 kΩ ~0.6 mA 2.4 Ah
Lithium content 0.65 g 5: 18 kΩ ~0.2 mA 2.3 Ah
Weight 18 g 0.5 6: 56 kΩ ~0.06 mA 2.1 Ah
7: 180 kΩ ~0.02 mA 1.9 Ah
Volume 8 cm3
0.0
Temperature range −55 °C ... +85 °C 0.1 1 10 102 103 104 105
Time / h

Available Capacity
2.5

3 4
2.0
Capacity to 2 Volts / Ah 2
SL-360/S SL-360/T 5
1
+0.2 1.5
Ø 4.2 −0.3

1.0

+
1: +72 °C
0.7±0.3

2: +55 °C
0.5 3: +25 °C
4: 0 °C
5: −30 °C
7±0.5 0.0
0.01 0.1 1 10 100 1000
50.5−1.5

3.17 Current / mA

0.15 thick
Operating Voltage
SL-360/P 3.8
5
3.6
Ø 0.8

Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
Ø 14.7–1.2 1
45 45 2.8
1: 20 mA
2.6 2: 6 mA
3: 2 mA
2.4 4: 0.2 mA
SL-360/PR SL-360/PT 5: 0.02 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
4+0,5

4+0,5
3.5

3.5

1−0.1 1−0.1 10.16

0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-360/S Standard 11 1 03601 00 WARNING:
SL-360/T Tags 11 1 03602 00 Fire, explosion, and
severe burn hazard. Do not
SL-360/P Pins 11 1 03603 00
recharge, disassemble, heat
PDC19Eng

SL-360/PR Pins radial 11 1 03606 00 above 100 °C, incinerate, or


SL-360/PT Polarized tags 11 1 03608 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 8 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-550 Size: 1/2AA


›› Extended temperature range
›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 0.9 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 0.6 mA 4
2.0 6 7 1: 180 Ω

Volts
Max. continuous discharge current 50 mA 34
5 ~20 mA 0.50 Ah
2: 560 Ω ~6 mA 0.80 Ah
Pulse current capability 100 mA 1.5 3 2
3: 1.8 kΩ ~2 mA 0.85 Ah
1 4: 5.6 kΩ ~0.6 mA 0.90 Ah
Anode surface area 6 cm2 1.0
5: 18 kΩ ~0.2 mA 0.85 Ah
Lithium content 0.35 g 2 6: 56 kΩ ~0.06 mA 0.80 Ah
0.5 0 2 4 6 s 10
7: 180 kΩ ~0.02 mA 0.70 Ah
Weight 9.6 g
0.0
Volume 4 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +130 °C Time / h

Available Capacity
1.2

1.0

Capacity to 2 Volts / Ah
SL-550/S SL-550/T 0.8 5
+0.2 4
Ø 4.2 −0.3
0.6 3
2 1 1: +120 °C 6
0.4 2: +80 °C
0.7±0.3

3: +50 °C
4: +25 °C
0.2 5: 0 °C
6: –30 °C
25.2–1.2

0.0
7±0.5 0.01 0.1 1 10 100 1000
3.17 Current / mA

0.15 thick
Operating Voltage
Ø 14.7 –1.2
SL-550/P 3.8
5
3.6
Ø 0.8
Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
1
45 45 2.8 1: 6 mA
2: 2 mA
2.6 3: 0.6 mA
4: 0.06 mA
2.4
SL-550/PR SL-550/PT 5: 0.006 mA
0
5
0
−5
10
25
40
55
70
85
0
5
0
5
−5
−3
−2

10
11
13
14

Temperature / °C
4+0.5

4+0.5
3.5

3.5

1–0.1 1–0.1 10.16


0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-550/S Standard 11 1 05501 00 WARNING:
SL-550/T Tags 11 1 05502 00 Fire, explosion, and
severe burn hazard. Do not
SL-550/P Pins 11 1 05503 00
recharge, disassemble, heat
PDC19Eng

SL-550/PR Pins radial 11 1 05506 00 above 150 °C, incinerate, or


SL-550/PT Polarized tags 11 1 05508 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 9 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-561 Size: 2⁄3AA


›› Extended temperature range
›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6 7
Nominal capacity 1.1 Ah 2.5

Voltage / V
Nominal current 1 mA 4
2.0 7

Volts
Max. continuous discharge current 75 mA 56 1: 100 Ω ~30 mA 0.60 Ah
34 2: 330 Ω ~10 mA
Pulse current capability 150 mA 1.5 3 2 0.80 Ah
3: 1 kΩ ~3 mA 1.00 Ah
1 4: 3.3 kΩ
Anode surface area 9 cm2 1.0 ~1 mA 1.10 Ah
5: 10 kΩ ~0.3 mA 1.10 Ah
Lithium content 0.5 g 2
0.5 0 2 4 6 s 10 6: 33 kΩ ~0.1 mA 1.00 Ah
7: 100 kΩ ~0.03 mA 0.85 Ah
Weight 12.5 g
0.0
Volume 5.2 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +130 °C Time / h

Available Capacity
1.6
1.4
Capacity to 2 Volts / Ah
1.2
SL-561/S SL-561/T
5
+0.2
1.0
Ø 4.2 −0.3
4
0.8 1
3
0.6 1: 120 °C

+
0.7±0.3

2 2: 80 °C
0.4 3: 50 °C
4: 25 °C
0.2 5: –30 °C

7 ±0.5 0.0
0 .0 1 0.1 1 10 100 1000
33.5−1.5

3.17 Current / mA
0.15 thick
Operating Voltage
SL-561/P 3.8
5
Ø 14.7−1.2 3.6
Ø 0.8

Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
1
45 45 2.8 1: 10 mA
2: 3 mA
2.6 3: 1 mA
4: 0.1 mA
2.4
SL-561/PR SL-561/PT 5: 0.01 mA
0
5
0
−5
10
25
40
55
70
85
0
5
0
5
−5
−3
−2

10
11
13
14

Temperature / °C
4+0.5

4+0.5
3.5

3.5

1−0.1 1−0.1 10.16

0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-561/S Standard 11 1 05611 00 WARNING:
SL-561/T Tags 11 1 05612 00 Fire, explosion, and
severe burn hazard. Do not
SL-561/P Pins 11 1 05613 00
recharge, disassemble, heat
PDC19Eng

SL-561/PR Pins radial 11 1 05616 00 above 150 °C, incinerate, or


SL-561/PT Polarized tags 11 1 05618 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 10 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-560 Size: AA
›› Extended temperature range
›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 1.8 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 2 mA 4
2.0 7

Volts
Max. continuous discharge current 100 mA 56 1: 56 Ω ~60 mA 1.40 Ah
34 2: 180 Ω ~20 mA
Pulse current capability 200 mA 1.5 3 2 1.60 Ah
3: 560 Ω ~6 mA 1.70 Ah
1 4: 1.8 kΩ
Anode surface area 14 cm2 1.0 ~2 mA 1.80 Ah
5: 5.6 kΩ ~0.6 mA 1.70 Ah
Lithium content 0.65 g 2
0.5 0 2 4 6 s 10 6: 18 kΩ ~0.2 mA 1.60 Ah
7: 56 kΩ ~0.06 mA 1.40 Ah
Weight 18 g
0.0
Volume 8 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +130 °C Time / h

Available Capacity
2.5

2.0

Capacity to 2 Volts / Ah
SL-560/S SL-560/T 5
+0.2 1.5 4
Ø 4.2 −0.3
3
1
1.0
2

+
1: 120 °C
0.7±0.3

2: 80 °C
0.5 3: 50 °C
4: 25 °C
5: –30 °C
7±0.5 0
0 .0 1 0.1 1 10 100 1000
50.5−1.5

3.17 Current / mA
0.15 thick
Operating Voltage
SL-560/P 3.8
5
3.6
Ø 0.8

Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
Ø 14.7–1.2 1
45 45 2.8 1: 20 mA
2: 6 mA
2.6 3: 2 mA
4: 0.2 mA
2.4
SL-560/PR SL-560/PT 5: 0.02 mA
0
5
0
−5
10
25
40
55
70
85
0
5
0
5
−5
−3
−2

10
11
13
14

Temperature / °C
4+0,5

4+0,5
3.5

3.5

1−0.1 1−0.1 10.16

0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-560/S Standard 11 1 05601 00 WARNING:
SL-560/T Tags 11 1 05602 00 Fire, explosion, and
severe burn hazard. Do not
SL-560/P Pins 11 1 05603 00
recharge, disassemble, heat
PDC19Eng

SL-560/PR Pins radial 11 1 05606 00 above 150 °C, incinerate, or


SL-560/PT Polarized tags 11 1 05608 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 11 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-750 Size: ½AA ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 1.1 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 1 mA 4
2.0 7
5 6

Volts
Max. continuous discharge current 50 mA 34
1: 180 Ω ~20 mA 0.5 Ah
1.5 2 2: 560 Ω ~6 mA 1.0 Ah
Pulse current capability 100 mA 3 3: 1.8 kΩ ~2 mA 1.1 Ah
1 4: 5.6 kΩ ~0.6 mA 1.1 Ah
Anode surface area 6 cm2 1.0
5: 18 kΩ ~0.2 mA 1.1 Ah
Lithium content 0.35 g 2 6: 56 kΩ ~0.06 mA 1.05 Ah
0.5 0 2 4 6 s 10
7: 180 kΩ ~0.02 mA 0.95 Ah
Weight 9.6 g
0.0
Volume 4 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
1.2
4
1.0
Capacity to 2 Volts / Ah 3
SL-750/S SL-750/T 0.8
+0.2
Ø 4.2 −0.3
0.6 2

1
0.4
0.7±0.3

1: +72 °C
2: +55 °C
0.2 3: +25 °C
4: −30 °C
25.2–1.2

0.0
7±0.5 0.01 0.1 1 10 100 1000
3.17 Current / mA

0.15 thick
Operating Voltage
Ø 14.7 –1.2
SL-750/P 3.8
5
3.6
Ø 0.8
Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
1
45 45 2.8 1: 6 mA
2: 2 mA
2.6 3: 0.6 mA
4: 0.06 mA
2.4 5: 0.006 mA
SL-750/PR SL-750/PT
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
4+0.5

4+0.5
3.5

3.5

Voltage Response at +25 °C, Pulse: 10 mA


3.8
Basic current (bc)
3.6 None 5 µA 10 µA
1–0.1 1–0.1 10.16 1
3.4 1 4
1 2
2 3 3
0.2 thick 0.2 thick 3.2
3 4
Voltage / V

3.0

Available Terminations Catalogue No. 2.8


SL-750/S Standard 11 1 07501 00 WARNING: 2.6 1: after 1 year at bc 3: after 5 years at bc
SL-750/T Tags 11 1 07502 00 Fire, explosion, and 2: after 2 years at bc 4: after 10 years at bc
2.4
severe burn hazard. Do not
SL-750/P Pins 11 1 07503 00
recharge, disassemble, heat
PDC19Eng

SL-750/PR Pins radial 11 1 07506 00 above 100 °C, incinerate, or 0 0.1 0.2 0 0.1 0 0.1
SL-750/PT Polarized tags 11 1 07508 00 expose contents to water. Time / s

Any values given here are for informational purposes only. They also depend on actual 12 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-761 Size: 2⁄3AA ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6 7
Nominal capacity 1.5 Ah 2.5

Voltage / V
Nominal current 1.3 mA 4
2.0 7

Volts
Max. continuous discharge current 75 mA 56 1: 100 Ω ~30 mA 0.80 Ah
34 2: 330 Ω ~10 mA
Pulse current capability 150 mA 1.5 3 2 1.35 Ah
3: 1.0 kΩ ~3 mA 1.50 Ah
1 4: 3.3 kΩ
Anode surface area 9 cm2 1.0 ~1 mA 1.50 Ah
5: 10 kΩ ~0.3 mA 1.50 Ah
Lithium content 0.5 g 2
0.5 0 2 4 6 s 10 6: 33 kΩ ~0.1 mA 1.45 Ah
7: 100 kΩ ~0.03 mA 1.30 Ah
Weight 12.5 g
0.0
Volume 5.2 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
1.6
4
1.4

Capacity to 2 Volts / Ah
3
SL-761/S SL-761/T 1.2
+0.2 1.0
Ø 4.2−0.3
0.8 2
1
0.6

+
0.7±0.3

1: +72 °C
0.4 2: +55 °C
3: +25 °C
0.2 4: −30 °C
7 ±0.5
0.0
33.5−1.5

0.01 0.1 1 10 100 1000


3.17 Current / mA
0.15 thick
Operating Voltage
SL-761/P 3.8
5
Ø 14.7−1.2 3.6
Ø 0.8

Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
1
45 45 2.8 1: 10 mA
2: 3 mA
2.6 3: 1 mA
2.4 4: 0.1 mA
SL-761/PR SL-761/PT 5: 0.01 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
4+0.5

4+0.5
3.5

3.5

Voltage Response at +25 °C, Pulse: 15 mA


3.8
Basic current (bc)
3.6 None 7.5 µA 15 µA
1 −0.1
1 −0.1
10.16
3.4 4 1
1 1 2
2 3 3
0.2 thick 0.2 thick 3 4
3.2
Voltage / V

3.0

Available Terminations Catalogue No. 2.8


SL-761/S Standard 11 1 07611 00 WARNING: 2.6 1: after 1 year at bc 3: after 5 years at bc
SL-761/T Tags 11 1 07612 00 Fire, explosion, and 2: after 2 years at bc 4: after 10 years at bc
2.4
severe burn hazard. Do not
SL-761/P Pins 11 1 07613 00
recharge, disassemble, heat
PDC19Eng

SL-761/PR Pins radial 11 1 07616 00 above 100 °C, incinerate, or 0 0.1 0.2 0 0.1 0 0.1
SL-761/PT Polarized tags 11 1 07618 00 expose contents to water. Time / s

Any values given here are for informational purposes only. They also depend on actual 13 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-760 Size: AA ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6 7
Nominal capacity 2.2 Ah 2.5

Voltage / V
Nominal current 2 mA 4
2.0 7
56

Volts
Max. continuous discharge current 100 mA 34
1: 56 Ω ~60 mA 1.4 Ah
1.5 2 2: 180 Ω ~20 mA 1.8 Ah
Pulse current capability 200 mA 3 3: 560 Ω ~6 mA 2.1 Ah
1 4: 1.8 kΩ
Anode surface area 14 cm2 1.0 ~2 mA 2.2 Ah
5: 5.6 kΩ ~0.6 mA 2.2 Ah
2
Lithium content 0.65 g 0.5 0 2 4 6 s 10
6: 18 kΩ ~0.2 mA 2.2 Ah
7: 56 kΩ ~0.06 mA 2.0 Ah
Weight 18 g
0.0
Volume 8 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
2.5

4
2.0
Capacity to 2 Volts / Ah 3
SL-760/S SL-760/T
+0.2 1.5
Ø 4.2 −0.3
2
1.0 1

+
1: +72 °C
0.7±0.3

2: +55 °C
0.5 3: +25 °C
4: −30 °C

7±0.5 0.0
0.01 0.1 1 10 100 1000
50.5−1.5

3.17 Current / mA

0.15 thick
Operating Voltage
SL-760/P 3.8
5
3.6
Ø 0.8

Ø 0.8

4
3.4 3
3.2
Voltage / V

2
3.0
Ø 14.7–1.2 1
45 45 2.8
1: 20 mA
2.6 2: 6 mA
3: 2 mA
2.4 4: 0.2 mA
SL-760/PR SL-760/PT 5: 0.02 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
4+0,5

4+0,5
3.5

3.5

Voltage Response at +25 °C, Pulse: 20 mA


3.8
Basic current (bc)
3.6 None 10 µA 20 µA
1
−0.1
1 −0.1
10.16
3.4 4 1
1 1 2
2 3 3
0.2 thick 0.2 thick 3 4
3.2
Voltage / V

3.0

Available Terminations Catalogue No. 2.8


SL-760/S Standard 11 1 07601 00 WARNING: 2.6 1: after 1 years at bc 3: after 5 years at bc
SL-760/T Tags 11 1 07602 00 Fire, explosion, and 2: after 2 years at bc 4: after 10 years at bc
2.4
severe burn hazard. Do not
SL-760/P Pins 11 1 07603 00
recharge, disassemble, heat
PDC19Eng

SL-760/PR Pins radial 11 1 07606 00 above 100 °C, incinerate, or 0 0.1 0.2 0 0.1 0 0.1
SL-760/PT Polarized tags 11 1 07608 00 expose contents to water. Time / s

Any values given here are for informational purposes only. They also depend on actual 14 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-2770 Size: C ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 8.5 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 3 mA 4
2.0 6 7

Volts
Max. continuous discharge current 230 mA 34
5 1: 33 Ω ~100 mA 2.2 Ah

Pulse current capability 400 mA 1.5 3 2 2: 100 Ω ~30 mA 5.8 Ah


3: 330 Ω ~10 mA 7.9 Ah
1
Anode surface area 30 cm2 1.0 4: 1.0 kΩ ~3 mA 8.5 Ah
5: 3.3 kΩ ~1 mA 8.4 Ah
Lithium content 2.5 g 2
0.5 0 2 4 6 s 10 6: 10 kΩ ~0.3 mA 7.8 Ah
7: 33 kΩ ~0.1 mA 6.9 Ah
Weight 49.5 g
0.0
Volume 26 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
10

8 3

Capacity to 2 Volts / Ah
SL-2770/S SL-2770/T
4
+0.2
6 2
Ø 4.2 −0.3

4 1 5
1: +72 °C
0.7±0.3

2: +55 °C
2 3: +25 °C
4: 0 °C
5: −30 °C
0
0.01 0.1 1 10 100 1000
Current / mA
50.0−2

Operating Voltage
+1 3.8
16−2
0.15 thick
3.6
7
3.4
3.17 6
5
3.2
Voltage / V

4
3.0 3 1: 60 mA
Ø 26.2−1 2: 30 mA
2.8 2 3: 10 mA
4: 3 mA
2.6 1 5: 1 mA
6: 0.3 mA
SL-2770/P 2.4 7: 0.1 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
Ø 0.8

Ø 0.8

Voltage Response at +25 °C, Pulse: 40 mA


3.8
Basic current (bc)
3.6 None 25 µA 45 µA
1
3.4 1 1 2
2
3.2
Voltage / V

2
3
45 45 3.0
4
2.8 3 3

WARNING: 2.6
Available Terminations Catalogue No. Fire, explosion, and 1: after 2 years at bc 3: after 8 years at bc
2.4 2: after 5 years at bc 4: after 10 years at bc
severe burn hazard. Do not
SL-2770/S Standard 11 2 17701 00
recharge, disassemble, heat
PDC19Eng

SL-2770/T Tags 11 2 17702 00 above 100 °C, incinerate, or 0 0.1 0.2 0 0.1 0 0.1
SL-2770/P Pins 11 2 17703 00 expose contents to water. Time / s

Any values given here are for informational purposes only. They also depend on actual 15 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-2780 Size: D ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 19 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 4 mA 4
2.0 6 7

Volts
Max. continuous discharge current 340 mA 34
5 1: 33 Ω ~100 mA 9.0 Ah

Pulse current capability 600 mA 1.5 3 2 2: 56 Ω ~60 mA 13.1 Ah


3: 180 Ω ~20 mA 16.9 Ah
1
Anode surface area 45 cm2 1.0 4: 560 Ω ~6 mA 18.7 Ah
5: 1.8 kΩ ~2 mA 18.6 Ah
Lithium content 5g 2
0.5 0 2 4 6 s 10 6: 5.6 kΩ ~0.6 mA 17.2 Ah
7: 18 kΩ ~0.2 mA 15.4 Ah
Weight 93 g
0.0
Volume 51 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
20
3

Capacity to 2 Volts / Ah 15
SL-2780/S SL-2780/T 2 4
+0.2
Ø 4.2 −0.3
10
1 5
1: +72 °C
2: +55 °C

+ 5 3: +25 °C
0.7±0.3

4: 0 °C
5: −30 °C

0
0.01 0.1 1 10 100 1000
Current / mA

Operating Voltage
3.8
+1
0.15 thick 3.6
61.5−2

12−2
3.4 7 6
5 4
3.17 3.2
Voltage / V

3
2
3.0 1: 100 mA
1 2: 60 mA
2.8 3: 20 mA
4: 6 mA
2.6 5: 2 mA
6: 0.6 mA
Ø 32.9−0.7 SL-2780/P 2.4 7: 0.2 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
Ø 0.8

Ø 0.8

Voltage Response at +25 °C, Pulse: 60 mA


3.8
Basic current (bc)
3.6 None 50 µA 100 µA

3.4 1 1 1
2
3.2
Voltage / V

2 2
3
3.0
45 45 4
2.8 3 3
4
WARNING: 2.6
Available Terminations Catalogue No. Fire, explosion, and 1: after 2 years at bc 3: after 8 years at bc
2.4
severe burn hazard. Do not 2: after 5 years at bc 4: after 10 years at bc
SL-2780/S Standard 11 2 17801 00
recharge, disassemble, heat
PDC19Eng

SL-2780/T Tags 11 2 17802 00 above 100 °C, incinerate, or 0 0.1 0.2 0 0.1 0 0.1
SL-2780/P Pins 11 2 17803 00 expose contents to water. Time / s

Any values given here are for informational purposes only. They also depend on actual 16 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-2790 Size: DD ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 35 Ah 1 2 3 4 5 6 7
2.5

Voltage / V
Nominal current 10 mA
2.0
Max. continuous discharge current 450 mA 1: 10 Ω ~300 mA 20.2 Ah

Pulse current capability 1000 mA 1.5 2: 33 Ω ~100 mA 28.7 Ah


3: 100 Ω ~30 mA 33.4 Ah
Anode surface area 90 cm2 1.0 4: 330 Ω ~10 mA 35.0 Ah
5: 1.0 kΩ ~3 mA 32.5 Ah
Lithium content 10 g 0.5 6: 3.3 kΩ ~1 mA 30.2 Ah
7: 10 kΩ ~0.3 mA 27.5 Ah
Weight 190 g
0.0
Volume 105 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
40
35 3

Capacity to 2 Volts / Ah
30 2
SL-2790/S 4
25
+0.2
Ø 4.2 −0.3
20 1 5
15 1: +72 °C
0.7±0.3

2: +55 °C
10 3: +25 °C
4: 0 °C
5 5: −30 °C

0
0.01 0.1 1 10 100 1000
Current / mA

Operating Voltage
3.8
+1
12−2 0.15 thick
3.6
3.4 7 6
3.17 5 4
3.2
Voltage / V

3
2
3.0 1: 300 mA
1
+0.2 SL-2790/T 2: 100 mA
Ø 4.2 2.8
123.5±1

−0.3
3: 30 mA
4: 10 mA
2.6 5: 3 mA
6: 1 mA
0.7±0.3

2.4 7: 0.3 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C

Voltage Response at +25 °C, Pulse: 120 mA


3.8
Basic current (bc)
3.6 None 100 µA 200 µA
+1
12−2 0.15 thick 3.4 1 1 1
2
3.2
Voltage / V

2 2
3.17 3
3.0
4
2.8 3 3
4
Ø 32.9−0.7 WARNING: 2.6
123.5±1

Fire, explosion, and 1: after 2 years at bc 3: after 8 years at bc


2.4 2: after 5 years at bc 4: after 10 years at bc
severe burn hazard. Do not
Available Terminations Catalogue No. recharge, disassemble, heat
PDC19Eng

SL-2790/S Standard 11 2 17901 00 above 100 °C, incinerate, or 0 0.1 0.2 0 0.1 0 0.1
SL-2790/T Tags 11 2 17902 00 expose contents to water. Time / s

Any values given here are for informational purposes only. They also depend on actual 17 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

TL-2450 Size: 1⁄10C ›› iXtra – long term high performance

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6
Nominal capacity 0.55 Ah 2.5

Voltage / V
Nominal current 0.5 mA 4
2.0 5 6

Volts
Max. continuous discharge current 5 mA 23
4
1: 3.3 kΩ ~1 mA 0.53 Ah
Pulse current capability 10 mA 1.5 3 1
2: 10 kΩ ~0.3 mA 0.55 Ah
3: 33 kΩ ~0.1 mA 0.54 Ah
Anode surface area 4.3 cm2 1.0 4: 100 kΩ ~0.03 mA 0.50 Ah
Lithium content 0.2 g 2 5: 330 kΩ ~0.01 mA 0.45 Ah
0.5 0 2 4 6 s 10 6: 1000 kΩ ~0.003 mA 0.42 Ah
Weight 8.8 g
0.0
Volume 2.6 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85°C Time / h

A high temperature version TLH-2450 is also available. Available Capacity


For more information please refer to Tadiran’s website. 0.6

0.5
3 2
Capacity to 2 Volts / Ah
TL-2450 (with insolation disc) 0.4 1

0.3 4

(−) (+) 1: +80 °C


0.2 2: +50 °C
5
3: +25 °C
0.1 4: 0 °C
5: −30 °C

0.0
Ø 24.0 +0.5 max. 0.01 0.1 1 10 100 1000
10.6 max.

Current / mA
6±0.2

Operating Voltage
3.8
3.6
Ø 0.785 3
7.62 3.4
2
3.2
Voltage / V

1
TL-2450 (without insolation disc) 3.0
10.6 max.

2.8
5.6±0.2

2.6
1: 2 mA
2.4 2: 0.2 mA
3: 0.02 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Ø 0.785 Temperature / °C
7.62

WARNING:
Fire, explosion, and
severe burn hazard. Do not
Available Terminations Catalogue No. recharge, disassemble, heat
PDC19Eng

TL-2450/P Pins (with insolation disc) 11 1 13763 02 above 100 °C, incinerate, or
TL-2450/P Pins (without insolation disc) 11 1 13763 22 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 18 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-889 Size: 1⁄10D ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6
Nominal capacity 1 Ah 2.5

Voltage / V
Nominal current 0.5 mA 4
2.0 5 6

Volts
Max. continuous discharge current 10 mA 23
4
1: 1.0 kΩ ~3 mA 0.98 Ah
Pulse current capability 20 mA 1.5 3 1 2: 3.3 kΩ ~1 mA 1.00 Ah
3: 10 kΩ ~0.3 mA 0.98 Ah
Anode surface area 7.5 cm2 1.0 4: 33 kΩ ~0.1 mA 0.95 Ah
Lithium content 0.3 g 2 5: 100 kΩ ~0.03 mA 0.92 Ah
0.5 0 2 4 6 s 10 6: 330 kΩ ~0.01 mA 0.85 Ah
Weight 16 g
0.0
Volume 5 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
1.2

1.0

Capacity to 2 Volts / Ah
SL-889 3
0.8
2
1
0.6 4
(–)
5
1: +80 °C
0.4 2: +50 °C
(+)
15.24

3: +25 °C
0.2 4: 0 °C
5: −30 °C
(–)
0.0
0.01 0.1 1 10 100 1000
Current / mA

Ø 33.0−0.8
Operating Voltage
3.8
3.6
6.2±0.3
3.2±0.5

(9.6)

3.4
3.2
Voltage / V

3.0
Ø 0.76 2.8
2 min.

7.62
2.6
1: 3 mA
2.4 2: 0.3 mA
3: 0.03 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C

WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
PDC19Eng

Available Terminations Catalogue No. above 100 °C, incinerate, or


SL-889/P Pins 11 1 18894 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 19 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-886 Size: 1⁄6D ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 1.7 Ah 1 2 3 4 5 6
2.5

Voltage / V
Nominal current 0.5 mA 4
2.0 5 6

Volts
Max. continuous discharge current 10 mA 23
4
1: 1.0 kΩ ~3 mA 1.50 Ah
Pulse current capability 20 mA 1.5 3 1 2: 3.3 kΩ ~1 mA 1.70 Ah
3: 10 kΩ ~0.3 mA 1.65 Ah
Anode surface area 7.5 cm2 1.0 4: 33 kΩ ~0.1 mA 1.60 Ah
Lithium content 0.5 g 2 5: 100 kΩ ~0.03 mA 1.50 Ah
0.5 0 2 4 6 s 10 6: 330 kΩ ~0.01 mA 1.40 Ah
Weight 21 g
0.0
Volume 8.2 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
2.0

Capacity to 2 Volts / Ah 1.5


3
SL-886 2
4
1
1.0
(−) 5
1: +80 °C
2: +50 °C
(+) 0.5
15.24

3: +25 °C
4: 0 °C
5: −30 °C
(−)
0.0
0.01 0.1 1 10 100 1000
Current / mA

Ø 33.0−0.8
Operating Voltage
3.8
(13.1)
9.9±0.3

3.6
3.2±0.5

3.4
3.2
Voltage / V

3.0
Ø 0.76 2.8
2 min.

7.62
2.6
1: 3 mA
2.4 2: 0.3 mA
3: 0.03 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C

WARNING:
Fire, explosion, and
severe burn hazard. Do not
recharge, disassemble, heat
PDC19Eng

Available Terminations Catalogue No. above 100 °C, incinerate, or


SL-886/P Pins 11 1 18864 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 20 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-850 Size: ½AA ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6
Nominal capacity 1.2 Ah 2.5

Voltage / V
Nominal current 0.5 mA 4
2.0 5 6

Volts
Max. continuous discharge current 20 mA 23
4
1: 1.8 kΩ ~2 mA 0.80 Ah
Pulse current capability 50 mA 1.5 3 1
2: 5.6 kΩ ~0.6 mA 1.20 Ah
3: 18 kΩ ~0.2 mA 1.15 Ah
Anode surface area 6 cm2 1.0 4: 56 kΩ ~0.06 mA 1.05 Ah
Lithium content 0.35 g 2 5: 180 kΩ ~0.02 mA 1.00 Ah
0.5 0 2 4 6 s 10 6: 560 kΩ ~0.006 mA 0.90 Ah
Weight 9.6 g
0.0
Volume 4 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
1.2
4
1.0 3

Capacity to 2 Volts / Ah
2
SL-850/S SL-850/T 0.8 1
5

+0.2
Ø 4.2 −0.3
0.6
1: +72 °C
0.4 2: +55 °C
0.7±0.3

3: +25 °C
0.2 4: 0 °C
5: −30 °C
25.2–1.2

0.0
7±0.5 0.01 0.1 1 10 100 1000
3.17 Current / mA

0.15 thick
Operating Voltage
Ø 14.7 –1.2
SL-850/P 3.8
3.6
Ø 0.8
Ø 0.8

3
3.4
2
3.2
Voltage / V

1
3.0
45 45 2.8
2.6 1: 2 mA
2: 0.2 mA
2.4 3: 0.02 mA
SL-850/PR SL-850/PT
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
4+0.5

4+0.5
3.5

3.5

1–0.1 1–0.1 10.16


0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-850/S Standard 11 1 08501 00 WARNING:
SL-850/T Tags 11 1 08502 00 Fire, explosion, and
severe burn hazard. Do not
SL-850/P Pins 11 1 08503 00
recharge, disassemble, heat
PDC19Eng

SL-850/PR Pins radial 11 1 08506 00 above 100 °C, incinerate, or


SL-850/PT Polarized tags 11 1 08508 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 21 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-861 Size: 2⁄3AA ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 1.6 Ah 1 2 3 4 5 6
2.5

Voltage / V
Nominal current 0.5 mA 4
2.0 5 6

Volts
Max. continuous discharge current 30 mA 23
4
1: 1.0 kΩ ~3 mA 1.20 Ah
Pulse current capability 75 mA 1.5 3 1 2: 3.3 kΩ ~1 mA 1.60 Ah
3: 10 kΩ ~0.3 mA 1.60 Ah
Anode surface area 9 cm2 1.0 4: 33 kΩ ~0.1 mA 1.55 Ah
Lithium content 0.5 g 2 5: 100 kΩ ~0.03 mA 1.45 Ah
0.5 0 2 4 6 s 10 6: 330 kΩ ~0.01 mA 1.35 Ah
Weight 12.5 g
0.0
Volume 5.2 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
1.6
5
4
1.4 3
Capacity to 2 Volts / Ah 2
SL-861/S SL-861/T 1.2
1
+0.2 1.0
Ø 4.2 −0.3
0.8
0.6 1: +72 °C

+
0.7±0.3

2: +55 °C
0.4 3: +25 °C
4: 0 °C
0.2 5: −30 °C

7 ±0.5
0.0
33.5−1.5

0.01 0.1 1 10 100 1000


3.17 Current / mA
0.15 thick
Operating Voltage
SL-861/P 3.8

Ø 14.7−1.2 3.6
Ø 0.8

Ø 0.8

3
3.4
2
3.2
Voltage / V

1
3.0
45 45 2.8
2.6 1: 3 mA
2: 0.3 mA
2.4 3: 0.03 mA
SL-861/PR SL-861/PT
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
4+0.5

4+0.5
3.5

3.5

1−0.1 1−0.1 10.16

0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-861/S Standard 11 1 08611 00 WARNING:
SL-861/T Tags 11 1 08612 00 Fire, explosion, and
severe burn hazard. Do not
SL-861/P Pins 11 1 08613 00
recharge, disassemble, heat
PDC19Eng

SL-861/PR Pins radial 11 1 08616 00 above 100 °C, incinerate, or


SL-861/PT Polarized tags 11 1 08618 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 22 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-860 Size: AA ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5 6
Nominal capacity 2.4 Ah 2.5

Voltage / V
Nominal current 1 mA 4
2.0 5 6

Volts
Max. continuous discharge current 60 mA 23
4
1: 560 Ω ~6 mA 1.90 Ah
Pulse current capability 120 mA 1.5 3 1 2: 1.8 kΩ ~2 mA 2.40 Ah
3: 5.6 kΩ ~0.6 mA 2.40 Ah
Anode surface area 14 cm2 1.0 4: 18 kΩ ~0.2 mA 2.30 Ah
Lithium content 0.65 g 2 5: 56 kΩ ~0.06 mA 2.15 Ah
0.5 0 2 4 6 s 10 6: 180 kΩ ~0.02 mA 2.00 Ah
Weight 18 g
0.0
Volume 8 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
2.5
4
2.0 3

Capacity to 2 Volts / Ah
2 5
SL-860/S SL-860/T
1
+0.2 1.5
Ø 4.2−0.3
1.0

+
1: +72 °C
0.7±0.3

2: +55 °C
0.5 3: +25 °C
4: 0 °C
5: −30 °C
7±0.5 0.0
0.01 0.1 1 10 100 1000
50.5−1.5

3.17 Current / mA

0.15 thick
Operating Voltage
SL-860/P 3.8
3.6
Ø 0.8

Ø 0.8

3
3.4
2
3.2
Voltage / V

1
3.0
Ø 14.7–1.2
45 45 2.8
2.6 1: 6 mA
2: 0.6 mA
2.4 3: 0.06 mA
SL-860/PR SL-860/PT
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
4+0,5

4+0,5
3.5

3.5

1−0.1 1−0.1 10.16

0.2 thick 0.2 thick

Available Terminations Catalogue No.


SL-860/S Standard 11 1 08601 00 WARNING:
SL-860/T Tags 11 1 08602 00 Fire, explosion, and
severe burn hazard. Do not
SL-860/P Pins 11 1 08603 00
recharge, disassemble, heat
PDC19Eng

SL-860/PR Pins radial 11 1 08606 00 above 100 °C, incinerate, or


SL-860/PT Polarized tags 11 1 08608 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 23 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-2870 Size: C ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
Nominal capacity 8.5 Ah 1 2 3 4 5
2.5

Voltage / V
Nominal current 3 mA 4
2.0 5
3 4

Volts
Max. continuous discharge current 75 mA 2
Pulse current capability 200 mA 1.5 3 1 1: 330 Ω ~10 mA 6.0 Ah
2: 1.0 kΩ ~3 mA 8.4 Ah
Anode surface area 30 cm2 1.0 3: 3.3 kΩ ~1 mA 8.5 Ah
Lithium content 2.5 g 2 4: 10 kΩ ~0.3 mA 8.2 Ah
0.5 0 2 4 6 s 10 5: 33 kΩ ~0.1 mA 7.7 Ah
Weight 49.5 g
0.0
Volume 26 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
10

8
Capacity to 2 Volts / Ah 2 3
SL-2870/S SL-2870/T 1
+0.2 6 4
Ø 4.2−0.3 5

4
1: +72 °C
0.7±0.3

2: +55 °C
2 3: +25 °C
4: 0 °C
5: −30 °C
0
0.01 0.1 1 10 100 1000
Current / mA
50.0−2

Operating Voltage
+1 3.8
16−2
0.15 thick
3.6
3
3.4
3.17 2
3.2
Voltage / V

3.0 1
Ø 26.2−1
2.8
2.6 1: 10 mA
2: 1 mA
SL-2870/P 2.4 3: 0.1 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
Ø 0.8

Ø 0.8

45 45

WARNING:
Available Terminations Catalogue No. Fire, explosion, and
severe burn hazard. Do not
SL-2870/S Standard 11 2 18701 00
recharge, disassemble, heat
PDC19Eng

SL-2870/T Tags 11 2 18702 00 above 100 °C, incinerate, or


SL-2870/P Pins 11 2 18703 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 24 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
LTC Batteries

SL-2880 Size: D ›› XOL – extended operating life

Performance Data Typical Discharge Curves at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System Lithium Thionyl Chloride 3.5


Nominal voltage 3.6 V 3.0
1 2 3 4 5
Nominal capacity 19 Ah 2.5

Voltage / V
Nominal current 4 mA 4
2.0 5
3 4

Volts
Max. continuous discharge current 100 mA 2
Pulse current capability 250 mA 1.5 3 1
1: 180 Ω ~20 mA 13.5 Ah
1.0 2: 560 Ω ~6 mA 17.5 Ah
Anode surface area 45 cm2 3: 1.8 kΩ ~2 mA 18.8 Ah
Lithium content 5g 2 4: 5.6 kΩ ~0.6 mA 18.3 Ah
0.5 0 2 4 6 s 10
5: 18 kΩ ~0.2 mA 17.0 Ah
Weight 93 g
0.0
Volume 51 cm3 0.1 1 10 102 103 104 105
Temperature range −55 °C ... +85 °C Time / h

Available Capacity
20

Capacity to 2 Volts / Ah
15 4
SL-2880/S SL-2880/T 1
+0.2 3
Ø 4.2−0.3
10
1: +80 °C 5
2: +50 °C

+ 5 3: +25 °C
0.7±0.3

4: 0 °C
5: −30 °C

0
0.01 0.1 1 10 100 1000
Current / mA

Operating Voltage
3.8
+1
0.15 thick 3.6
61.5−2

12−2 3
3.4
2
3.17 3.2
Voltage / V

1
3.0
2.8
2.6 1: 20 mA
2: 2 mA
Ø 32.9−0.7 SL-2880/P 2.4 3: 0.2 mA

−50 −35 −20 −5 10 25 40 55 70 85 100


Temperature / °C
Ø 0.8

Ø 0.8

45 45

WARNING:
Available Terminations Catalogue No. Fire, explosion, and
severe burn hazard. Do not
SL-2880/S Standard 11 2 18801 00
recharge, disassemble, heat
PDC19Eng

SL-2880/T Tags 11 2 18802 00 above 100 °C, incinerate, or


SL-2880/P Pins 11 2 18803 00 expose contents to water.

Any values given here are for informational purposes only. They also depend on actual 25 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
PulsesPlus  TM Batteries

Introduction
The PulsesPlus  TM battery Advantages than 10 or 20 years. However,
The PulsesPlus  TM battery series The performance advan- after 2 years, the voltage
was introduced by Tadiran tages of the PulsesPlus  TM level under pulse load starts
Batteries in order to extend battery include: to decline reaching as low as How to Design a Long Life Application
the range of applications for 320

Higher voltage – 3.6 V 1.5 Volts after 5 years. At this


the Lithium Thionyl Chloride versus 3.0 V voltage level, most applica- 280

Max. avg. current draw / μA


1: +70 °C
(LTC) battery by eliminating the

Higher capacity – e.g. 19 Ah tions would stop to work and


240 2: +55 °C
voltage delay, increasing the for D size cell (versus 7 Ah the battery would be consid- 3: +25 °C
3
pulse current capability and for other Lithium batteries) ered as discharged. However, 200 2
minimizing the impedance loss 1 TLP-93111/A

Lower self discharge – less it is not, as can be seen from


160 (SL-2880, D-size, XOL cell,
of the battery. A proprietary Hy- than 1 % per year the red curve showing the bat- 19 Ah nominal capacity,
brid Layer Capacitor (HLC) was (versus 5 % per year tery voltage under background 120 with HLC-1550A)
developed for this purpose. A with spiral wound) load. It stays at 3.6 Volts,
80
PulsesPlus  TM battery is formed

Lower impedance even after 5 and 10 years.


by connecting one or more (internal resistance) Connecting Tadiran’s Hybrid 40
primary lithium thionyl chloride

High pulse current Layer Capacitor (HLC) in paral- 0


batteries in parallel with one or capability lel solves the problem. The 0 5 10 15 20 25 30
more HLCs.

No passivation effect HLC maintains its low internal Typical battery design life / years

High reliability resistance throughout the Figure 3: How to Design a Long Life Application
The Hybrid Layer Capacitor (hermetic laser sealing, remaining battery life. During
This HLC is a secondary element. glass-to-metal seal) that time period the pulse
Its electrodes comprise Lithium

Widest operating tem- voltage stays always above 3.4 various temperature levels Fit for 20 years of life
Intercalated Compounds and perature – −40 °C to +85 °C Volts. The duration for that between −40 °C and +25 °C. Figure 3 shows the maximum
are spirally wound. The HLC has (versus 0 °C to +60 °C) test is more than 14 years. The chart shows two curves average current draw of a TLP-
been optimized with respect

Greater safety, UL registra- for each temperature level. 93111/A PulsesPlus  TM battery
to self discharge, temperature tion of the component cells Application in The upper curve corresponds as a function of the design life
range and durability by carefully GSM modules to the voltage level under the of the battery. This battery will
selecting the material properties No impedance loss One major application for background current of 150 mA typically deliver 20 years opera-
of the electrodes and the her- The PulsesPlus  TM battery PulsesPlus  TM batteries is in while the lower curve cor- tion life when the average cur-
metical glass to metal seal. overcomes the impedance GSM communication modules responds to the voltage level rent is not more than 87.5 µA at
loss which occurs when an LTC for data exchange. GSM is under the peak current of 2 A. +25 °C. Under these conditions,
Performance battery is used to deliver high the global system for mobile Curves at higher temperatures the accumulated self discharge
As a result, the PulsesPlus  TM pulse currents over a long communication also used are not shown but can be con- loss of the battery is less than
battery outperforms conven- time. This effect is demonstrat- for mobile phones. The GSM sidered to lie slightly above 15 % during its operating life.
tional high rate lithium bat- ed in figure 1 where a D-size network uses a multiplexing the curves for +25 °C. As a result it is fair to say that
technology called time divi- Tadiran’s Pulses­Plus  TM battery
Impedance Loss and how to Overcome it sion multiple access (TDMA) Extremely low is the smallest and most cost
4.0 R-420 in order to provide multiple self discharge effective battery for a 20 year
1
3.5 communication channels with The PulsesPlus  TM battery can stand alone power supply.
the same signal, dividing it be used where 20 years of
3.0 SL-2880 @ +25 °C
cont. load: 68 kΩ (~50 µA) into 8 time slots. A typical continuous power are required Variable design
2.5 2 pulse load: 150 mA TDMA transmission requires for applications including PulsesPlus  TM batteries can be
Voltage / V

1: Voltage on background current


a basic current of 150 mA GSM and radio modules. This assembled in a great variety of
2.0 2: Pulse voltage
and a pulse current of 2 A is due to the stability of both combinations. The primary cell
1.5 for 577 µs every 4.615 ms. Tadiran’s primary LTC battery can be selected from Tadiran’s
Figure 2 shows the voltage and the HLC with respect large range of 3.6 Volt LTC bat-
1.0 HLC-1520 connected behaviour of a Pulses­Plus  TM to the sealing system, the teries. A special range of LSC
0.5 battery with one HLC-1550A internal resistance, and the (Lithium Sulphuryl Chloride)
under these conditions at self-discharge. cells with a nominal voltage
0.0 of 3.9 Volts is also available,
0 5 10 15 20
Working time / years often allowing a more economic
GSM Discharge Curves
4.0 approach where equipment
Figure 1: Impedance Loss and how to Overcome it
needs to operate at very low
3.5 temperatures. Each of these
teries such as lithium sulphur cell was discharged under a 3.0 primary cells can be combined
dioxide (Li/SO2) batteries, continuous load of ~50 µA and with one or more HLCs from a
2.5
Voltage / V

5 4 3 1
lithium manganese dioxide short pulses of 150 mA. 2 range of four sizes. Series and
(Li/MnO2) batteries as well as 2.0 7 6 parallel combinations of more
spirally wound lithium thionyl The battery is able to de- HLC-1550A charged to 3.6 V primary cells extend the voltage
1.5 GSM profile (TDMA, 1 Slot)
chloride (Li/SOCl2) batteries. liver this current at a voltage 150 mA continuous current range and capacity range where
Compared to these battery level of 3 Volts, at least for a 1.0 2 A peak current for 577 µs every 4.615 ms necessary. Only a few standard
systems, PulsesPlus  TM batter- period of 2 years. From the 1: +25 °C 2: +10 °C 3: 0 °C combinations can be shown in
0.5 4: −10 °C 5: −20 °C
ies deliver higher voltage and low average current draw of 6: −30 °C 7: −40 °C this catalogue. Contact Tadiran
higher capacity. These batteries 50 µA, one would be misled 0.0 for a customized application
also offer unmatched service to assume that the battery 0 5 10 15 20 25 proposal.
PDC19Eng

life due to their extremely low could continue to deliver Time / min
self-discharge. these pulse currents for more Figure 2: GSM Discharge Curves

Any values given here are for informational purposes only. They also depend on actual 26 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-91111/A ›› Up to 3 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 2.4 Ah 3.6 1
2

Voltage / V
3
Nominal current 2 mA
3.4
Max. 1 s pulse to 3 V 3A 1: 300 mA
Max. pulse length @ 0.5 A to 2.8 V 1000 s 3.2 2: 750 mA
3: 1500 mA
Delay time to 3 V @ 0.5 A none
Weight 55 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 87 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


4.0
1: −40 °C
3.5 2: −20 °C
3: 0 °C
3.0

Pulse amplitude / A
4: +25 °C
TLP-91111/A/SM 5: +85 °C
2.5
2.0
100±10 4&5
1.5
3
1.0
2
0.5 1
55 max.

0.0
0.01 0.1 1 10 102 103 104
Pulse width / s

Pulse Voltage after 1 s


4.0
F
3.8
B C
3.6
Voltage / V

32 max. 3.4 1: 300 mA


B = LTC battery 1 2 2: 600 mA
3
3: 1000 mA
C = HLC 3.2
F = PTC (optional)
3.0
Both the LTC battery and the
HLC are UL recognized. 2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
16 max.

Available Capacity
2.5
4
2.0 3
Capacity to 2 Volts / Ah

2 5
1
1.5

1.0
1: +72 °C
WARNING: 2: +55 °C
Risk of fire or explosion. 0.5 3: +25 °C
4: 0 °C
Do not charge, incinerate, 5: −30 °C
disassemble, heat above 0.0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-91111/A/SM Flying leads 17 91111 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 27 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-91311/A ›› Up to 1 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 2.4 Ah 3.6 1
2

Voltage / V
3
Nominal current 2 mA
3.4
Max. 1 s pulse to 3 V 1A 1: 100 mA
2: 250 mA
Max. pulse length @ 0.125 A to 2.8 V 1000 s 3.2 3: 500 mA
Delay time to 3 V @ 0.125 A none
Weight 40 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 90 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


1.2
1: −40 °C
1.0 2: −20 °C
Pulse amplitude / A 3: 0 °C
TLP-91311/A/SM 4: +25 °C
TLP-91311/A/ST 0.8 5: +85 °C

Ø7 Ø7 Ø7 Ø7
0.6
3 4&5
0.4

+ + + +18±2 18±2
0.2
1
2

0.0
0.01 0.1 1 10 102 103 104
Pulse width / s

Pulse Voltage after 1 s


75 max.

75 max.

75 max.

4.0
F
3.8
B C
3.6
Voltage / V

3.4 1: 100 mA
B = LTC battery 1 2 2: 200 mA
3
3: 300 mA
C = HLC 3.2
F = PTC (optional)
3.0
Both the LTC battery and the
HLC are UL recognized. 2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
Ø 16.5 max. Ø 16.5 max. Ø 16.5 max. Ø 16.5 max.
23±2 23±2

Available Capacity
2.5
4
2.0 3
Capacity to 2 Volts / Ah

2 5
1
1.5

1.0
1: +72 °C
WARNING: 2: +55 °C
Do not charge. Battery can 0.5 3: +25 °C
4: 0 °C
explode if disassembled,
Available Terminations Catalogue No. heated above 100 °C,
5: −30 °C
0.0
PDC19Eng

TLP-91311/A/SM Pressure contacts 17 91311 101 incinerated, or contents 0.01 0.1 1 10 100 1000
TLP-91311/A/ST Solder tags 17 91311 102 exposed to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 28 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-92111/A ›› Up to 3 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 8.5 Ah 3.6 1
2

Voltage / V
3
Nominal current 3 mA
3.4
Max. 1 s pulse to 3 V 3A 1: 300 mA
Max. pulse length @ 0.5 A to 2.8 V 1000 s 3.2 2: 750 mA
3: 1500 mA
Delay time to 3 V @ 0.5 A none
Weight 100 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 93 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


4.0
1: −40 °C
3.5 2: −20 °C
3: 0 °C
3.0

Pulse amplitude / A
4: +25 °C
TLP-92111/A/SM 5: +85 °C
2.5
2.0
4&5
100±10 1.5
3
1.0
2
0.5 1
55 max.

0.0
Note: 0.01 0.1 1 10 102 103 104
For best performance battery Pulse width / s
should be mounted in the ap-
plication in upright
or horizontal orientation. Pulse Voltage after 1 s
4.0
F
3.8
B C
3.6
Voltage / V

44 max. 3.4 1: 300 mA


B = LTC battery 1 2 2: 600 mA
3
3: 1000 mA
C = HLC 3.2
F = PTC (optional)
3.0
Both the LTC battery and the
HLC are UL recognized. 2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
28 max.

Available Capacity
10

8
Capacity to 2 Volts / Ah

2 3
1
6 4
5

4
1: +72 °C
WARNING: 2: +55 °C
Risk of fire or explosion. 2 3: +25 °C
4: 0 °C
Do not charge, incinerate, 5: −30 °C
disassemble, heat above 0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-92111/A/SM Flying leads 17 92111 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 29 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-92311/A ›› Up to 1 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 8.5 Ah 3.6 1
2

Voltage / V
3
Nominal current 3 mA
3.4
Max. 1 s pulse to 3 V 1A 1: 100 mA
2: 250 mA
Max. pulse length @ 0.125 A to 2.8 V 1000 s 3.2 3: 500 mA
Delay time to 3 V @ 0.125 A none
Weight 80 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 93 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


1.2
1: −40 °C
1.0 2: −20 °C
Pulse amplitude / A 3: 0 °C
TLP-92311/A/SM 4: +25 °C
0.8 5: +85 °C

0.6
3 4&5
75±10
0.4
2
0.2
1

Note: 0.0
0.01 0.1 1 10 102 103 104
For best performance battery Pulse width / s
67 max.

should be mounted in the ap-


plication in upright
or horizontal orientation. Pulse Voltage after 1 s
4.0
F
3.8
B C
3.6
Voltage / V

3.4 1: 100 mA
B = LTC battery 1 2 2: 200 mA
3
3: 300 mA
C = HLC 3.2
F = PTC (optional)
Ø 29 max.
3.0
Both the LTC battery and the
HLC are UL recognized. 2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C

Available Capacity
10

8
Capacity to 2 Volts / Ah

2 3
1
6 4
5

4
1: +72 °C
WARNING: 2: +55 °C
Risk of fire or explosion. 2 3: +25 °C
4: 0 °C
Do not charge, incinerate, 5: −30 °C
disassemble, heat above 0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-92311/A/SM Flying leads 17 92311 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 30 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-93111/A ›› Up to 3 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 19 Ah 3.6 1
2

Voltage / V
3
Nominal current 4 mA
3.4
Max. 1 s pulse to 3 V 3A 1: 300 mA
Max. pulse length @ 0.5 A to 2.8 V 1000 s 3.2 2: 750 mA
3: 1500 mA
Delay time to 3 V @ 0.5 A none
Weight 140 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 96 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


4.0
1: −40 °C
3.5 2: −20 °C
3: 0 °C
3.0

Pulse amplitude / A
4: +25 °C
5: +85 °C
2.5
2.0
4&5
1.5
TLP-93111/A/SM 3
1.0
2
0.5 1
100±10 0.0
0.01 0.1 1 10 102 103 104
Pulse width / s

Note: Pulse Voltage after 1 s


4.0
64 max.

For best performance battery


should be mounted in the ap- 3.8
plication in upright
or horizontal orientation. 3.6
Voltage / V

F 3.4 1: 300 mA
1 2 2: 600 mA
3
3: 1000 mA
B C 3.2

3.0
B = LTC battery
2.8
C = HLC −50 −35 −20 −5 10 25 40 55 70 85 100
50 max. F = PTC (optional) Temperature / °C

Both the LTC battery and the


HLC are UL recognized. Available Capacity
20
35 max.

2
Capacity to 2 Volts / Ah

15 4
1
3

10
1: +80 °C 5
2: +50 °C
WARNING: 5 3: +25 °C
Risk of fire or explosion. 4: 0 °C
Do not charge, incinerate, 5: −30 °C
disassemble, heat above 0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-93111/A/SM Flying leads 17 93111 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 31 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-93311/A ›› Up to 1 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 19 Ah 3.6 1
2

Voltage / V
3
Nominal current 4 mA
3.4
Max. 1 s pulse to 3 V 1A 1: 100 mA
2: 250 mA
Max. pulse length @ 0.125 A to 2.8 V 1000 s 3.2 3: 500 mA
Delay time to 3 V @ 0.125 A none
Weight 120 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 96 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


1.2
1: −40 °C
1.0 2: −20 °C
Pulse amplitude / A 3: 0 °C
4: +25 °C
0.8 5: +85 °C

0.6
3 4&5

TLP-93311/A/SM 0.4
2
0.2
1

75±10 0.0
0.01 0.1 1 10 102 103 104
Pulse width / s

Note: Pulse Voltage after 1 s


4.0
For best performance battery
should be mounted in the ap-
3.8
78 max.

plication in upright
or horizontal orientation.
3.6
Voltage / V

F 3.4 1: 100 mA
1 2 2: 200 mA
3
3: 300 mA
B C 3.2

3.0
B = LTC battery
2.8
C = HLC −50 −35 −20 −5 10 25 40 55 70 85 100
F = PTC (optional) Temperature / °C
Both the LTC battery and the
HLC are UL recognized.
Available Capacity
Ø 34 max. 20

2
Capacity to 2 Volts / Ah

15 4
1
3

10
1: +80 °C 5
2: +50 °C
WARNING: 5 3: +25 °C
Risk of fire or explosion. 4: 0 °C
Do not charge, incinerate, 5: −30 °C
disassemble, heat above 0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-93311/A/SM Flying leads 17 93311 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 32 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-96111/A ›› Up to 3 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 1.2 Ah 3.6 1
2

Voltage / V
3
Nominal current 0.6 mA
3.4
Max. 1 s pulse to 3 V 3A 1: 300 mA
Max. pulse length @ 0.5 A to 2.8 V 1000 s 3.2 2: 750 mA
3: 1500 mA
Delay time to 3 V @ 0.5 A none
Weight 45 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 78 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


4.0
1: −40 °C
3.5 2: −20 °C
3: 0 °C
3.0

Pulse amplitude / A
4: +25 °C
TLP-96111/A/SM 5: +85 °C
2.5
2.0
4&5
100±10 1.5
3
1.0
2
0.5 1
0.0
55 max.

0.01 0.1 1 10 102 103 104


Pulse width / s

Pulse Voltage after 1 s


4.0
F
3.8
B C
3.6
Voltage / V

32 max. 3.4 1: 300 mA


B = LTC battery 1 2 2: 600 mA
3
3: 1000 mA
C = HLC 3.2
F = PTC (optional)
3.0
Both the LTC battery and the
HLC are UL recognized. 2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
16 max.

Available Capacity
1.2
4
1.0 3
Capacity to 2 Volts / Ah

2
5
0.8 1

0.6
1: +72 °C
0.4 2: +55 °C
WARNING: 3: +25 °C
Risk of fire or explosion. 0.2 4: 0 °C
Do not charge, incinerate, 5: −30 °C
disassemble, heat above 0.0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-96111/A/SM Flying leads 17 96111 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 33 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-96311/A ›› Up to 1 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 1.2 Ah 3.6 1
2

Voltage / V
3
Nominal current 0.6 mA
3.4
Max. 1 s pulse to 3 V 1A 1: 100 mA
2: 250 mA
Max. pulse length @ 0.125 A to 2.8 V 1000 s 3.2 3: 500 mA
Delay time to 3 V @ 0.125 A none
Weight 30 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 83 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


1.2
1: −40 °C
1.0 2: −20 °C
Pulse amplitude / A 3: 0 °C
4: +25 °C
TLP-96311/A/SM TLP-96311/A/ST 0.8 5: +85 °C

Ø7 Ø7 Ø7 Ø7
0.6
3 4&5
0.4

+ + + +
18±2 18±2
0.2
1
2

0.0
0.01 0.1 1 10 102 103 104
Pulse width / s
50 max.

50 max.

50 max.

Pulse Voltage after 1 s


4.0

3.8

3.6
Voltage / V

3.4 1: 100 mA
Ø 16.5 max. Ø 16.5 max. Ø 16.5 max. Ø 16.523
max.
±2
23±2 1 2
3
2: 200 mA
3: 300 mA
3.2

3.0
F
2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
B C Temperature / °C

B = LTC battery Available Capacity


1.2
C = HLC
F = PTC (optional) 4
1.0 3
Capacity to 2 Volts / Ah

2
Both the LTC battery and the 5
HLC are UL recognized. 0.8 1

0.6
1: +72 °C
0.4 2: +55 °C
WARNING: 3: +25 °C
Do not charge. Battery can 0.2 4: 0 °C
explode if disassembled, 5: −30 °C
Available Terminations Catalogue No. heated above 100 °C, 0.0
PDC19Eng

TLP-96311/A/SM Pressure contacts 17 96311 101 incinerated, or contents 0.01 0.1 1 10 100 1000
TLP-96311/A/ST Solder tags 17 96311 102 exposed to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 34 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-97111/A ›› Up to 3 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 1.6 Ah 3.6 1
2

Voltage / V
3
Nominal current 1 mA
3.4
Max. 1 s pulse to 3 V 3A 1: 300 mA
Max. pulse length @ 0.5 A to 2.8 V 1000 s 3.2 2: 750 mA
3: 1500 mA
Delay time to 3 V @ 0.5 A none
Weight 45 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 80 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


4.0
1: −40 °C
3.5 2: −20 °C
3: 0 °C
3.0

Pulse amplitude / A
4: +25 °C
TLP-97111/A/SM 5: +85 °C
2.5
2.0
100±10 4&5
1.5
3
1.0
2
F 0.5 1
55 max.

0.0
B C 0.01 0.1 1 10 102 103 104
Pulse width / s

B = LTC battery
Pulse Voltage after 1 s
C = HLC 4.0
F = PTC (optional)
3.8
Both the LTC battery and the
HLC are UL recognized.
3.6
Voltage / V

32 max. 3.4 1: 300 mA


1 2 2: 600 mA
3
3: 1000 mA
3.2

3.0

2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C
16 max.

Available Capacity
1.6
5
4
1.4 3
Capacity to 2 Volts / Ah

2
1.2
1
1.0
0.8
0.6 1: +72 °C
2: +55 °C
WARNING: 0.4 3: +25 °C
Risk of fire or explosion. 4: 0 °C
Do not charge, incinerate, 0.2 5: −30 °C
disassemble, heat above
0.0
PDC19Eng

Available Terminations Catalogue No. 100 °C, or expose 0.01 0.1 1 10 100 1000
TLP-97111/A/SM Flying leads 17 97111 101 contents to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 35 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High energy

TLP-97311/A ›› Up to 1 A pulse capability


›› Instant voltage response
›› No passivation effect

Performance Data Voltage during a Pulse at +25 °C


(Typical values for batteries stored at +25 °C for one year) 4.0

System LTC and HLC 3.8


Nominal voltage 3.6 V
Nominal capacity 1.6 Ah 3.6 1
2

Voltage / V
3
Nominal current 1 mA
3.4
Max. 1 s pulse to 3 V 1A 1: 100 mA
2: 250 mA
Max. pulse length @ 0.125 A to 2.8 V 1000 s 3.2 3: 500 mA
Delay time to 3 V @ 0.125 A none
Weight 35 g 3.0
Temperature range −40 °C ... +85 °C
2.8
Capacity retention after 10 year storage 85 % 0.01 0.1 1 10 102 103 104
Pulse duration / s

Maximum Pulse Width from 3.6 V to 2.8 V


1.2
1: −40 °C
1.0 2: −20 °C
Pulse amplitude / A 3: 0 °C
4: +25 °C
TLP-97311/A/SM TLP-97311/A/ST 0.8 5: +85 °C

Ø7 Ø7 Ø7 Ø7
0.6
3 4&5
0.4

+ + + +18±2 18±2
0.2
1
2

0.0
F 0.01 0.1 1 10 102 103 104
Pulse width / s
B C
58 max.

58 max.

58 max.

Pulse Voltage after 1 s


4.0
B = LTC battery
C = HLC 3.8
F = PTC (optional)
3.6
Both the LTC battery and the
Voltage / V

HLC are UL recognized.


3.4 1: 100 mA
1 2 2: 200 mA
3
3: 300 mA
3.2
Ø 16.5 max. Ø 16.5 max. Ø 16.5 max. Ø 16.5 max.
23 ±2
23 ±2
3.0

2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C

Available Capacity
1.6
5
4
1.4 3
Capacity to 2 Volts / Ah

2
1.2
1
1.0
0.8
0.6 1: +72 °C
2: +55 °C
WARNING: 0.4 3: +25 °C
Do not charge. Battery can 4: 0 °C
explode if disassembled, 0.2 5: −30 °C
Available Terminations Catalogue No. heated above 100 °C,
0.0
PDC19Eng

TLP-97311/A/SM Pressure contacts 17 97311 101 incinerated, or contents 0.01 0.1 1 10 100 1000
TLP-97311/A/ST Solder tags 17 97311 102 exposed to water. Current / mA

Any values given here are for informational purposes only. They also depend on actual 36 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Hybrid Layer Capacitors (HLCs)

Introduction
Properties
Hybrid Layer Capacitors are a
kind of rechargeable battery.
They are used as a capacitor in
PulsesPlus  TM batteries, where Temperature range −40 °C ... +85 °C for operation in PulsesPlus  TM batteries
they are connected in parallel −30 °C ... +60 °C for storage and independent use
to Tadiran Lithium Batteries.
The electrodes of HLCs com-
prise Lithium intercalation
Electrical characteristics
compounds. They have low im-
Discharge end voltage 2.5 V Discharge below 2.5 V at +25 °C and discharge below 2 V at −40 °C
pedance and can deliver high
may lead to an increase of the internal resistance.
current pulses. The perform-
Max. charge voltage 3.95 V
ance and reliability properties
of HLCs have been carefully
optimized to match those of
Tadiran Lithium Batteries. Shelf life in PulsesPlus  TM batteries used independently
The result is a battery with a @ +25 °C 10 years 3 years
maximum of both energy and @ +60 °C 7 years 4 weeks
power density for stand alone @ +85°C ≥ 1 year 1 week
use of up to 25 years.

Safety Cycle life at 3.6 V at 3.9 V


WARNING: to 1 % DOD1) 400000 cycles 100000 cycles
HLCs are designed for use in to 10 % DOD 40000 cycles 10000 cycles
PulsesPlus  TM batteries. When to 100 % DOD 4000 cycles 1000 cycles
used independently, they must
not be fast charged. 1) DOD = depth of discharge

Overcharge above 3.95 V may


lead to capacity loss and/or an
increase of internal resistance.

Overcharge above 4.4 V may


lead to excessive internal
pressure. This may result in
explosion or rupture.

HLCs must not be charged


after a deep discharge below
2.5 Volts.

Transport
HLCs have passed the UN
transport tests. They contain
less than 1 Wh nominal
energy and are not restricted
under international dangerous
goods regulations. Connected
to a Tadiran Lithium Thionyl
Chloride battery, the resulting
hybrid battery can be trans-
ported according to UN 3090.
For more information on
classification and transport
regulations, please refer to
Tadiran’s technical notice:
www.tadiranbatteries.de/
regulations/
PDC19Eng

Any values given here are for informational purposes only. They also depend on actual 37 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› Delivering high current pulses

HLC-1020 ›› Up to 25 years lifetime and more


›› Wide operating temperature range
›› Low self discharge

Performance Data Voltage during a Pulse at +25 °C


(Typical values in PulsesPlus  TM batteries stored at +25 °C) 4.0

System Lithium Intercalated Compounds 3.8


Version HLC-1020 (HLC-1020L)
Nominal voltage 3.7 V 3.6 1
2

Voltage / V
Nominal capacity 45 As @ 3.7 V (30 As @ 3.7 V) 3
3.4
Nominal current 15 mA 1: 30 mA
Max. continuous discharge current 250 mA (150 mA) 2: 75 mA
3.2 3: 150 mA
Pulse current capability 750 mA (500 mA)
Max. charge voltage 3.95 V 3.0
Max. charge current 8 mA (6 mA)
2.8
Discharge end voltage 2.5 V 0.01 0.1 1 10 102 103 104
Cell impedance max. 400 mΩ (max. 600 mΩ) Pulse duration / s
Nominal energy 0.07 Wh
Weight 4.2 g Maximum Pulse Width from 3.6 V to 2.8 V
For more data please refer to page 37. 0.4
1: −40 °C
2: −20 °C
Ø 10 ±0.5
Pulse amplitude / A 0.3 3: 0 °C
HLC-1020(L)/T 4: +25 °C
HLC-1020(L)/S 5: +85 °C
Ø 10±0.5

+
0.2
21−1

3 4&5

+ 0.1
21−1

2
7±1
1
3.17
0.0
7±1 0.01 0.1 1 10 102 103 104
3.17 Pulse width / s
HLC-1020(L)/TP

Pulse Voltage after 1 s


3.7±0.5 3.7±0.5

4.0

3.8

0.7±0.02 7.5 3.6


Voltage / V

3.4 1: 30 mA
0.7±0.02 7.5 1 2
3
2: 60 mA
3: 100 mA
3.2

3.0

2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C

Voltage Curve at +25 °C


4.0
3.8
Open circuit voltage / V

3.6
3.4
3.2 15 mA discharge
Available Terminations Catalogue No. CAUTION:
HLC-1020/S Standard 13 0 11021 02 Fire, explosion, 3.0
and severe burn hazard.
HLC-1020/T Tags 13 0 11022 02 Do not disassemble, heat 2.8
HLC-1020/TP Polarized tags 13 0 11027 02 above 100 °C, or incinerate. 2.6
HLC-1020L/S Standard 13 0 13021 02
Use as part of PulsesPlus™
PDC19Eng

HLC-1020L/T Tags 13 0 13022 02 battery only. Do not 0.01 0.1 1 10 102 103
HLC-1020L/TP Polarized tags 13 0 13027 02 charge above 3.95 V. Available capacity / As

Any values given here are for informational purposes only. They also depend on actual 38 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› Delivering high current pulses

HLC-1520A ›› Up to 25 years lifetime and more


›› Wide operating temperature range
›› Low self discharge

Performance Data Voltage during a Pulse at +25 °C


(Typical values in PulsesPlus  TM batteries stored at +25 °C) 4.0

System Lithium Intercalated Compounds 3.8


Nominal voltage 3.7 V
Nominal capacity 140 As (39 mAh) @ 3.7 V 3.6 1
2

Voltage / V
Nominal current 25 mA 3
3.4
Max. continuous discharge current 500 mA 1: 100 mA
Pulse current capability 2000 mA 2: 250 mA
3.2 3: 500 mA
Max. charge voltage 3.95 V
Max. charge current 25 mA 3.0
Ø 15.5 −1
Discharge end voltage 2.5 V
2.8
Cell impedance max. 250 mΩ (@ 1 kHz, RT) 0.01 0.1 1 10 102 103 104
Nominal energy 0.22 Wh Pulse duration / s

+
Weight 7.7 g
21−1

For more data please refer to page 37. Maximum Pulse Width from 3.6 V to 2.8 V
1.2
7±1 1: −40 °C
1.0 2: −20 °C
0.13 3.17 3: 0 °C

Pulse amplitude / A
4: +25 °C
HLC-1520/S
Ø 14.5+0.2 HLC-1520/T 0.8 5: +85 °C

0.6
Ø 15.5−1 4&5
3
Ø 15.5−1
0.4

++
2
0.2
3.7±0.5

4.0±0.5

1
21−1

0.0
21−1

0.01 0.1 1 10 102 103 104


Pulse width / s
7 ±1

0.2 0.7
7±1±0.02
0.13 3.17
Ø 14.5 +0.2 0.13 3.17 Pulse Voltage after 1 s
Ø 14.5+0.2 4.0
HLC-1520/TP
3.8

3.6
Voltage / V
±0.5
±0.5
3.7±0.5

4.0±0.5

3.4 1: 100 mA
3.7±0.5

±0.5
3.7

4.0

1 2 2: 200 mA
3
3: 300 mA
4.0

3.2

3.0
0.2 0.7±0.02
±0.02
7.5
0.2 0.7±0.02 2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C

Voltage Curve at +25 °C


4.0
4.0±0.5
3.7±0.5

3.8
4.0±0.5
3.7±0.5

Open circuit voltage / V

3.6
3.4
0.2 0.7 3.2 50 mA discharge
CAUTION:7.5
±0.02

0.2 0.7±0.02 7.5


Fire, explosion, 3.0
and severe burn hazard.
Do not disassemble, heat 2.8
Available Terminations Catalogue No. above 100 °C, or incinerate. 2.6
HLC-1520A/S Standard 13 0 11521 02
Use as part of PulsesPlus™
PDC19Eng

HLC-1520A/T Tags 13 0 11522 02 battery only. Do not 0.01 0.1 1 10 102 103
HLC-1520A/TP Polarized tags 13 0 11527 02 charge above 3.95 V. Available capacity / As

Any values given here are for informational purposes only. They also depend on actual 39 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› Delivering high current pulses

HLC-1530A ›› Up to 25 years lifetime and more


›› Wide operating temperature range
›› Low self discharge

Performance Data Voltage during a Pulse at +25 °C


(Typical values in PulsesPlus  TM batteries stored at +25 °C) 4.0

System Lithium Intercalated Compounds 3.8


Nominal voltage 3.7 V
Nominal capacity 250 As (70 mAh) @ 3.7 V 3.6 1
2

Voltage / V
Nominal current 50 mA 3
3.4
Max. continuous discharge current 750 mA
1: 150 mA
Pulse current capability 3000 mA 3.2 2: 400 mA
3: 750 mA
Max. charge voltage 3.95 V
Max. charge current 50 mA 3.0
Discharge end voltage 2.5 V
2.8
Cell impedance max. 140 mΩ (@ 1 kHz, RT) 0.01 0.1 1 10 102 103 104
Nominal energy 0.4 Wh Pulse duration / s
Weight 10.3 g
For more data please refer to page 37. Maximum Pulse Width from 3.6 V to 2.8 V
2.0
1: −40 °C
2: −20 °C
3: 0 °C
Pulse amplitude / A 1.5 4: +25 °C
HLC-1530/S HLC-1530/T 5: +85 °C

1.0
Ø 15.5−1 4&5
Ø 15.5−1
3
0.5

+
+ 0.0
1
2
28−1

0.01 0.1 1 10 102 103 104


28−1

7±1 Pulse width / s


0.13 7±1 3.17
0.13 3.17
Pulse Voltage after 1 s
4.0
HLC-1530/TP
Ø 14.5+0.2 3.8
Ø 14.5+0.2
3.6
±0.5 ±0.5

±0.5 ±0.5

Voltage / V
3.73.7

4.04.0

3.4 1: 150 mA
1 2 2: 300 mA
3
3: 500 mA
3.2
0.2 0.7±0.02 7.5
0.2 0.7±0.02 7.5 3.0

2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C

Voltage Curve at +25 °C


4.0
3.8
Open circuit voltage / V

3.6
3.4
3.2
CAUTION:
Fire, explosion, 3.0
and severe burn hazard.
2.8 100 mA discharge
Do not disassemble, heat
Available Terminations Catalogue No. above 100 °C, or incinerate. 2.6
HLC-1530A/S Standard 13 0 11531 02
Use as part of PulsesPlus™
PDC19Eng

HLC-1530A/T Tags 13 0 11532 02 battery only. Do not 0.01 0.1 1 10 102 103
HLC-1530A/TP Polarized tags 13 0 11537 02 charge above 3.95 V. Available capacity / As

Any values given here are for informational purposes only. They also depend on actual 40 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› Delivering high current pulses

HLC-1550A ›› Up to 25 years lifetime and more


›› Wide operating temperature range
›› Low self discharge

Performance Data Voltage during a Pulse at +25 °C


(Typical values in PulsesPlus  TM batteries stored at +25 °C) 4.0

System Lithium Intercalated Compounds 3.8


Nominal voltage 3.7 V
Nominal capacity 560 As (155 mAh) @ 3.7 V 3.6 1
2

Voltage / V
Nominal current 50 mA 3
3.4
Max. continuous discharge current 2000 mA
1: 300 mA
Pulse current capability 5000 mA 3.2 2: 750 mA
3: 1500 mA
Max. charge voltage 3.95 V
Ø 15.5
Max.
-1
charge current 100 mA 3.0
Discharge end voltage 2.5 V
2.8
Cell impedance max. 100 mΩ (@ 1 kHz, RT) 0.01 0.1 1 10 102 103 104

+
Nominal energy
Weight
0.86 Wh
20 g
Pulse duration / s

For more data please refer to page 37. Maximum Pulse Width from 3.6 V to 2.8 V
7±1 4.0
1: −40 °C
52-1

0.13 3.17 3.5 2: −20 °C


3: 0 °C
3.0

Pulse amplitude / A
4: +25 °C
HLC-1550/S HLC-1550/T 5: +85 °C
2.5

Ø 15.5 -1 2.0
4&5
Ø 15.5-1 1.5
3
3.7±0.5

1.0

+
4.0±0.5

+ 0.5
0.0
0.01 0.1
1

1 10 102 103 104


Ø 14.5+0.2 Pulse width / s
7±1 ±0.02
0.2 0.7
7±1
-1

0.13 3.17
52-152

0.13 3.17 Pulse Voltage after 1 s


4.0
HLC-1550/TP
3.8

3.6
±0.5
±0.5

Voltage / V
±0.5

±0.5
4.0
3.7

3.4 1: 300 mA
3.73.7
±0.5

4.04.0
±0.5

1 2 2: 600 mA
3
3: 1000 mA
3.2
Ø 14.5 +0.2
0.2 0.7±0.02 7.5
Ø 14.5+0.2 0.2 0.7±0.02 3.0
0.2 0.7±0.02
2.8
−50 −35 −20 −5 10 25 40 55 70 85 100
Temperature / °C

Voltage Curve at +25 °C


4.0
±0.5±0.5
±0.5±0.5

3.8
4.04.0
3.73.7

Open circuit voltage / V

3.6
3.4
0.2 0.7±0.02 7.5 3.2
0.2 0.7±0.02 CAUTION: 7.5
Fire, explosion, 3.0
and severe burn hazard.
2.8 200 mA discharge
Do not disassemble, heat
Available Terminations Catalogue No. above 100 °C, or incinerate. 2.6
HLC-1550A/S Standard 13 0 11551 02
Use as part of PulsesPlus™
PDC19Eng

HLC-1550A/T Tags 13 0 11552 02 battery only. Do not 0.01 0.1 1 10 102 103
HLC-1550A/TP Polarized tags 13 0 11557 02 charge above 3.95 V. Available capacity / As

Any values given here are for informational purposes only. They also depend on actual 41 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Introduction
The TLM battery Outperforms competition Smallest high Enduring low
The Tadiran TLM series, the Compared to other commer- power battery impedance
newest product innovation cial high rate lithium batter- Figure 2 shows the behav- For demanding applications
from Tadiran Batteries, is ies, TLM batteries are superior iour of TLM-1550HPM under like the back-up battery in
distinguished by its extremely with respect to their voltage, these conditions. The battery eCall systems, the durability
high power in the decisive energy content, and tempera- was subjected to accelerated of the battery in a wide tem-
moment – when it really mat- ture behaviour. ageing by storing it at +72 °C perature range is a decisive
for 3 weeks prior to the test. factor. Especially two para-
Comparison TLM versus Li/MnO2
1 : TLM-1550/HPM under 2 A @ +25 °C CDMA Discharge after Accelerated Ageing
4.0 2 : TLM-1550/HPM under 1 A @ –20 °C
3 : CR123A under 2 A @ +25 °C 4.0
4 : CR123A under 1 A @ –20 °C TLM-1550HPM
1
3.5 discharge @ –20 °C
after 3 weeks storage @ +72 °C
2 3.5
Voltage / V

1: 0.5 A for 3.75 ms every 6.25 ms, followed by


Voltage / V

3.0 2: 2.5 A for 2.5 ms

3.0
1
2.5 2
3 2.5
4
2.0
2.0
0 0.1 0.2 0.3 0.4 0.5 0.6
Capacity / Ah 0 5 10 15
Figure 1: Comparison TLM versus Li/MnO2 Time / min
Figure 2: CDMA Discharge after Accelerated Ageing
ters! It stands for guaranteed Figure 1 shows a comparison
power even after long storage with CR123A batteries. These It was then cooled down to meters need to be sufficiently
or stand-by up to more than batteries have almost the −20 °C and discharged under low and stable: self discharge
10 years. Its outstanding same volume as TLM-1550HPM a simulated application load and internal resistance. The
properties make it the ideal and belong to the Lithium profile comprising 2.5 A of development of self discharge,
back-up battery for the eCall Manganese Dioxide 3 Volt 2.5 ms duration every 6.25 ms expressed as capacity loss over
system, surgical instruments, system. Under a 2 Ampere dis- on a basic load of 0.5 A. The storage time, is shown in the
and other special applications. charge at room temperature, upper curve (1) shows the data sheets of TLM batteries
they deliver almost the same voltage on the basic load on the following pages while
Military version capacity as TLM-1550HPM but while the lower curve (2) Figure 3 shows the develop-
TLM batteries are also avail- at much lower voltage. Under
able in a more robust version 1 Ampere discharge at −20 °C,
Impedance Growth during Storage
for military applications. CR123A delivers almost no 200
capacity above 2 Volts, while
Advantages TLM-1550HPM still delivers
TLM-1550HPM

High voltage 4.0 V more than 70 % of its nomi-


Internal resistance / mΩ

150 1: @ RT

Very high pulse nal capacity. 2: @ +72 °C


current capability

Immediate response, Application in 100


no passivation effect eCall modules 2

Wide operating One major application for


temperature range TLM batteries is the so-called 50 1
(−40 °C to +85 °C) Autonomous Telematics Box or

High reliability Advanced Telematics Module


(hermetic laser sealing, where the TLM battery serves 0
glass-to-metal seal) as the back-up battery for 0 500 1000 1500 2000
Time / days

Outstanding storage eCall, the automatic emer-


capability (up to 10 years) gency call system for cars in Figure 3: Impedance Growth during Storage

Recognized safety (UL) Europe. The requirements for

Very low self discharge this system include operation shows the voltage during the ment of the internal resistance

Easy health monitoring under high pulse currents at 2.5 A pulses. The discharge of TLM-1550HPM over time
during storage low temperature at any time up duration is clearly in excess at two different storage tem-
to 10 years after installation. of 10 minutes. TLM-1550HPM peratures. It remains within
Even under these severe condi- is the smallest battery com- the specified limits, even after
tions, an air time of more than mercially available on the storage at +72 °C for 3 years.
10 minutes is required. Dur- market that can fulfil these
ing this air time, the system requirements.
exchanges both car condition
and position data and voice
PDC19Eng

signals between the car and an


emergency call centre.

Any values given here are for informational purposes only. They also depend on actual 42 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High power 4 Volt cell

TLM-1520HPM ›› No voltage delay


›› Long shelf life
›› End of life indication capability

Performance Data Discharge Capability at RT


(Typical values for batteries stored at +25 °C for one year) 4.5
4
System Lithium Metal Oxide
Nominal voltage 4.0 V 3.5
Nominal capacity 125 mAh 3

Voltage / V
1 2 3
Nominal current 5 mA 2.5
Max. continuous discharge current 1.75 A 2
Pulse current capability 3.75 A 1.5 1: 1 A
2: 125 mA
Cell impedance max. 100 mΩ 1 3: 5 mA
Anode surface area 90 cm2 0.5
Lithium content 0.04 g 0
Weight 9g 0 20 40 60 80 100 120 140
Volume 3.2 cm3 Capacity / mAh
Temperature range −40 °C ... +85 °C
Discharge at 250 mA and several Temperatures
4.5
4
3.5
4
TLM-1520HPM/S TLM-1520HPM/T 3
3
Voltage / V 2.5
1 2
Ø 15.5−1 2
Ø 15.5−1
1.5 1: −40 °C
2: −20 °C

+
1 3: +22 °C

+
4: +85 °C
21−1

0.5
21−1

0
0 20 40 60 80 100 120
7±1
Capacity / mAh
7±1
0.13 3.17
Ø 14.5+0.2 0.13 3.17
Ø 14.5+0.2 Ageing during Storage
TLM-1520HPM/TP 50
Accumulated capacity loss1) / %

1: +25 °C
40 2: +55 °C
3 3: +70 °C
2
±0.5 ±0.5
±0.5 ±0.5

30
4.04.0
3.73.7

20
1
0.2 0.7±0.02 7.5
0.2 0.7±0.02 7.5 10
1)
when tested at RT under 12 mA to 2.8 V

0
0 5 10 15 20 25
Time / years

Voltage Curve

4.0

3.5
Voltage / V

3.0

2.5
WARNING:
Available Terminations Catalogue No. Fire, explosion,
and severe burn hazard. Do 2.0
TLM-1520HPM/S Standard 12 0 22521 02
not charge, disassemble,
PDC19Eng

TLM-1520HPM/T Tags 12 0 22522 02 heat above 100 °C, 0 25 50 75 100 125 150
TLM-1520HPM/TP Polarized tags 12 0 22527 02 incinerate, or short circuit. Capacity / mAh

Any values given here are for informational purposes only. They also depend on actual 43 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High power 4 Volt cell

TLM-1530HPM ›› No voltage delay


›› Long shelf life
›› End of life indication capability

Performance Data Discharge Capability at RT


(Typical values for batteries stored at +25 °C for one year) 4.5
4
System Lithium Metal Oxide
Nominal voltage 4.0 V 3.5
1 2
Nominal capacity 225 mAh 3
4

Voltage / V
3
Nominal current 9 mA 2.5
Max. continuous discharge current 3.2 A 2
1: 1.8 A
Pulse current capability 6.8 A 1.5 2: 450 mA
Cell impedance max. 100 mΩ 3: 225 mA
1 4: 9 mA
Anode surface area 160 cm2 0.5
Lithium content 0.1 g 0
Weight 11 g 0 50 100 150 200 250
Volume 4.4 cm3 Capacity / mAh
Temperature range −40 °C ... +85 °C
Discharge at 450 mA and several Temperatures
4.5
4
3.5
TLM-1530HPM/S TLM-1530HPM/T 3
4
3
Voltage / V

2.5 2
1
Ø 15.5–1 2
Ø 15.5–1 1.5 1: −40 °C
2: −20 °C

+
1 3: +22 °C

+
4: +85 °C
0.5
0
28–1

0 50 100 150 200 250


28–1

7±1 Capacity / mAh


7±1
0.13 3.17
0.13 3.17
Ageing during Storage
TLM-1530HPM/TP 50
Accumulated capacity loss1) / %

Ø 14.5+0.2 40 1: +25 °C
Ø 14.5+0.2 2: +55 °C
3 3: +70 °C
2
±0.5 ±0.5
±0.5 ±0.5

30
4.04.0
3.73.7

20
1
0.2 0.7±0.02 7.5
10
0.2 0.7±0.02 7.5 1)
when tested at RT under 20 mA to 2.8 V

0
0 5 10 15 20 25
Time / years

Voltage Curve

4.0

3.5
Voltage / V

3.0

2.5
WARNING:
Available Terminations Catalogue No. Fire, explosion,
and severe burn hazard. Do 2.0
TLM-1530HPM/S Standard 12 0 22531 02
not charge, disassemble,
PDC19Eng

TLM-1530HPM/T Tags 12 0 22532 02 heat above 100 °C, 0 50 100 150 200 250 300
TLM-1530HPM/TP Polarized tags 12 0 22537 02 incinerate, or short circuit. Capacity / mAh

Any values given here are for informational purposes only. They also depend on actual 44 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› High power 4 Volt cell

TLM-1550HPM ›› No voltage delay


›› Long shelf life
›› End of life indication capability

Performance Data Discharge capability at RT


(Typical values for batteries stored at +25 °C for one year) 4.5
System Lithium Metal Oxide 4
Nominal voltage 4.0 V
3.5
Nominal capacity 500 mAh

Voltage / V
Nominal current 100 mA 3
2
Max. continuous discharge current 7A 2.5
Pulse current capability 15 A 1 3
2 1: 5 A
Cell impedance max. 100 mΩ 2: 2.5 A
Anode surface area 360 cm2 1.5 3: 0.5 A

Lithium content 0.4 g 1


Weight 20 g 0 100 200 300 400 500 600
Volume 8 cm3 Capacity / mAh
Temperature range −40 °C ... +85 °C
Discharge capability @ 2A at several temperatures
4.00
1: –40 °C
2: –30 °C
3: –20 °C
3.50 4: +22 °C
TLM-1550HPM/S TLM-1550HPM/Z2/T 5: +72 °C
3.00
Voltage / V 4 5
Ø 15.5 -1

Ø 15,5-1 2.50 3
2

+
1
2.00

+ 1.50
7±1 0 100 200 300 400 500
7±1 Capacity / mAh
51-151-1

0.13 3.17
0,13 3,17
Ageing during Storage
TLM-1550HPM/Z2/TP 50
Accumulated capacity loss1) / %

1: +25 °C
40 2: +55 °C
3 3: +70 °C
±0,5±0.5
±0,5±0.5

2
30
4,04.0
3,73.7

20
Ø 14.5+0.2
1
Ø 14,5+0,2 0.2 0.7±0.02
7.5
0,2 0,7±0,02 7,5 10
1)
when tested at RT under 50 mA to 2.8 V

0
0 5 10 15 20 25
Time / years

Voltage Curve

4.0

3.5
Voltage / V

3.0

2.5
Available Terminations Catalogue No. WARNING:
TLM-1550HPM/S Standard 12 0 22551 02 Fire, explosion,
and severe burn hazard. Do 2.0
TLM-1550HPM/Z2/T Tags* 12 1 22552 02
not charge, disassemble,
PDC19Eng

TLM-1550HPM/Z2/TP Polarized tags* 12 1 22557 02 heat above 100 °C, 0 100 200 300 400 500 600
* with PTC SRP 200 incinerate, or short circuit. Capacity / mAh

Any values given here are for informational purposes only. They also depend on actual 45 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Introduction
TLI-Battery
The TLI series is specifi- Characteristics 18650 Li-Ion TLI-1550A minutes is re-
cally designed for long-term Dimensions Ø 18 mm x 64 mm Ø 15 mm x 50 mm quired. During this air time,
use in harsh environments. Capacity 3.2 Ah 0.4 Ah the system exchanges both car Approval by Tadiran
It represents an important Power: condition and position data The design of the following
breakthrough in recharge- 18 W and voice signals between the items should be approved by
@ +25 °C 18W
able lithium-ion battery car and an emergency call Tadiran:
@ –20 °C <3W >6W
technology. centre.

Implementation of the
Temperature range: protection circuit against
Standard rechargeable lithium Storage –20 °C to +60 °C –40 °C to +85 °C Figure 2 shows the behaviour overcharge, e.g. by limita-
ion cells have inherent draw- Discharge –20 °C to +60 °C –40 °C to +85 °C of TLI-1550 in a typical eCall tion of the charging voltage
backs which have an impact Charge ±0 °C to +45 °C –40 °C to +85 °C application after an ageing and charging current to
on long term applications. period of one month at 72 °C. the values given in the
Self discharge 20 % per year < 5 % per year
These include short operating The GSM transmission profile individual data sheets
life (maximum 5 years), low Operating life 5 years 10+ years of the application requires a

Implementation of
maximum cycle life (1000 cy- Table 1: Comparison of TLI-1550 versus 2 A pulse for the duration of low voltage protection
cles), high self-discharge (up a standard lithium ion cell 18650 577 µs followed by a 150 mA against deep discharge
to 60 % per year), and limited Charging Principle CCCV pulse for 4.6 ms. This load
temperature range (0 °C to alternation is continuously
60 °C) with no possibility 4.0 200 repeated. Even at a tempera-
of charging at low and high 1 ture of –40 °C a TLI-1550 cell
temperatures. 1: Voltage ensures an air time of more
3.5 2: Current 150
than 15 minutes.
Current / mA
Voltage / V

By contrast, TLI series batter-


ies utilize technology found in 3.0 2 100 Protection
Tadiran’s patented hybrid lay- In order to ensure a high level
er capacitor (HLC). Tadiran’s of safety, TLI cells 1530 and
2.5 50
technology has been field- 1550 should be protected by
proven in millions of cells to a PTC either on the battery or
deliver 25 years and more 2.0 0 on the PC-board. Recommend-
service life. TLI series batter- ed PTC types include SRP120
Time
ies modify this technology to and SRP200, respectively, as
deliver reliable, long-term Figure 1: Charging principle CCCV. Example for TLI-1550 follows: SRP120 limits the
performance under extreme discharge current to 1.2 A
environmental conditions. Figure 1 shows the constant the so-called Autonomous and SRP200 to 2 A. In special
current/constant voltage Telematics Box or Advanced cases cells can be used with-
Characteristics (CCCV) charging principle Telematics Module where out PTC.

Wide operating tempera- which is recommended for the TLI battery serves as the
ture (– 40 °C to + 85 °C) the TLI series. The battery back-up battery for eCall, the TLI batteries have no inte-

Short time storage up is charged with a constant automatic emergency call grated overcharge protec-
to + 90 °C possible current until the maximum system for cars in Europe. The tion. The protection circuit

Ability to deliver high voltage is reached. Afterwards, requirements for this system should be designed by the
current pulses (up to 5 A) the charging current is de- include operation under high customer and be approved by

Low self-discharge (less creased to maintain constant pulse currents at low tem- Tadiran. Please refer to the TLI
than 5 % per year) voltage. Charging may be perature at any time up to 10 guidelines posted on Tadiran’s

Up to 5 times extended discontinued when a prede- years after installation. Even website under products >>
cycle life (5000 full charge/ fined end-of-charge current is under these severe conditions, TLI-batteries.
discharge cycles) reached. With the maximum an air time of more than 10

Long operating current, charging takes ap-


time (10 years) proximately 6.5 hours in the GSM Discharge Curves

Charging possible at temperature range between


1: 2.0 A / 577 µs +20 °C
extreme temperatures –20 °C and +50 °C. In the 4.0 2: 150 mA / 4.6 ms –10 °C
(10h-rate) extended temperature range –30 °C
2 –40 °C

Hermetically sealed cell between –40 °C and +85 °C the 3.5 1


(glass-to-metal seal) maximum charging current is 2
Voltage / V

Certified safety (UL) five times lower, resulting in 1

Easy monitoring of cell a five times longer charging 3.0


fitness during storage time. 2
1
2.5
Table 1 shows a comparison TLI in eCall applications 2
of a standard lithium ion cell The TLI battery ensures con- 1
18650 with the TLI-1550. It stant power supply even under 2.0
can be seen that the charac- high current pulses. This is
0 5 1510 20 25 30 35
teristics of the TLI series are required for applications like Time / min
superior in terms of power, bidirectional wireless commu-
PDC19Eng

Figure 2: Discharge behaviour of TLI-1550 under the GSM profile


self-discharge and operating nication modules. One major after storage at 72 °C for one month
temperature range. application for TLI batteries is

Any values given here are for informational purposes only. They also depend on actual 46 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE

TLI-1020A ›› Up to 5000 cycles


›› Extremely low self discharge rate
›› Charging possible at extreme temperatures

Performance Data Discharge Curve at 25 °C


(Typical values for batteries stored at +25 °C for one year)
4.0 1: 400 mA
System Lithium Intercalated Compounds 2: 200 mA
Nominal voltage 4V 3: 100 mA
3.5 4: 10 mA
Max. capacity 25 mAh

Voltage / V
Max. continuous discharge current 160 mA
3.0
Pulse current capability 400 mA 1
2 3
Discharge end voltage 2.5 V 4
2.5
Max. charge voltage 4.1 V
Max. charge current 8 mA 1.6 mA
Temperature range 2.0
–20 °C ... +50 °C – 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT max. 600 mΩ 0 5 10 15 20 25 30
Nominal energy 0.09 Wh Capacity / mAh
Weight 4.2 g
For more information please refer to page 46.
Discharge Curve at 100 mA

4.0 1: –40 °C
TLI-1020A/S
Ø 10±0.5 TLI-1020A/T 2: –30 °C
3: –20 °C
3.5 4: 0 °C
5: +22 °C
Ø 10±0.5 Voltage / V

+ 3.0
21−1

+ 2.5
1 2 3 4 5
21−1

7±1
3.17 2.0
7±1
0 5 10 15 20 25 30
3.17 Capacity / mAh
TLI-1020A/TP
3.7±0.5 3.7±0.5

Cycling Performance
40

30
Capacity / mAh

0.7±0.02 7.5

0.7±0.02 7.5 20

10

0
0 1000 2000 3000 4000
Cycles

Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
Available Terminations Catalogue No. incinerate or expose
TLI-1020A/S Standard 13 2 11021 02 contents to water.
PDC19Eng

TLI-1020A/T Tags 13 2 11022 02 Do not charge above 4.1 V.


TLI-1020A/TP Polarized tags 13 2 11027 02 Please refer to TLI-guidelines.

Any values given here are for informational purposes only. They also depend on actual 47 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE

TLI-1520A ›› Up to 5000 cycles


›› Extremely low self discharge rate
›› Charging possible at extreme temperatures

Performance Data Discharge Curve at 25 °C


(Typical values for batteries stored at +25 °C for one year)
4.0 1: 1250 mA
System Lithium Intercalated Compounds 2: 625 mA
Nominal voltage 4V 3: 250 mA
3.5 4: 50 mA
Max. capacity 90 mAh

Voltage / V
Max. continuous discharge current 500 mA 1
3.0 2
Pulse current capability 1.25 A
3
Dischage end voltage 2.5 V 4
2.5
Max. charge voltage 4.1 V
Max. charge current 25 mA 5 mA
2.0
Temperature range –20 °C ... +50 °C – 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT max. 250 mΩ 0 20 40 60 80 100 120
Nominal energy 0.3 Wh Capacity / mAh
Weight 9g
For more information please refer to page 46. Discharge Curve at 500 mA

4.0 1: −40 °C
TLI-1520A/Z2 TLI-1520A/Z2/T 2: −30 °C
3: −20 °C
3.5 4: 0 °C
Ø 15.5-1 5: +22 °C
Voltage / V

Ø 15.5−1 5
3.0 4

+
3
2.5 2

+ 1
21+2

7 ±1 2.0
0.13 7±1 3.17 0 20 40 60 80 100 120
52+2

0.13 3.17 Capacity / mAh

TLI-1520A/Z2/TP
Ø 14.5+0.2 Cycling Performance
120
4.0±0.5
3.7±0.5

90
4.0±0.5
3.7±0.5

Capacity / mAh

60
Ø 14.5+0.2 0.2 0.7±0.02 7.5
0.2 0.7±0.02 7.5
30

0
0 1000 2000 3000 4000
Cycles

Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
Available Terminations Catalogue No. incinerate or expose
TLI-1520A/Z2/T Tags* 13 3 11522 02 contents to water.
TLI-1520A/Z2/TP Polarized tags* 13 3 11527 02
PDC19Eng

Do not charge above 4.1 V.


* with PTC SRP 200 Please refer to TLI-guidelines.

Any values given here are for informational purposes only. They also depend on actual 48 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE

TLI-1530A ›› Up to 5000 cycles


›› Extremely low self discharge rate
›› Charging possible at extreme temperatures

Performance Data Discharge Curve at 25 °C


(Typical values for batteries stored at +25 °C for one year)
4.0 1: 2500 mA
System Lithium Intercalated Compounds 2: 1250 mA
Nominal voltage 4V 3: 500 mA
3.5 4: 50 mA
Max. capacity 150 mAh

Voltage / V
Max. continuous discharge current 1 A 1
3.0
Pulse current capability 2.5 A
Dischage end voltage 2.5 V
2.5
Max. charge voltage 4.1 V
Max. charge current 50 mA 10 mA
2.0
Temperature range –20 °C ... +50 °C – 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT max. 175 mΩ 0 25 50 75 100 125 150
Nominal energy 0.5 Wh Capacity / mAh
Weight 10 g
For more information please refer to page 46. Discharge Curve at 1 A

4.0 1: −40 °C
TLI-1530A/Z2 TLI-1530A/Z2/T 2: −30 °C
3: −20 °C
3.5 4: 0 °C
Ø 15.5-1 5: +22 °C
Ø 15.5−1 Voltage / V
5
4
3.0
3

+
2
2.5

+
1

7±1 2.0
+2
52+229

0.13 7±1 3.17 0 25 50 75 100 125 150


0.13 3.17 Capacity / mAh

TLI-1530A/Z2/TP
Cycling Performance
160

Ø 14.5+0.2
±0.5±0.5
±0.5±0.5

120
4.04.0
3.73.7

Capacity / mAh

80
Ø 14.5+0.2 0.2 0.7±0.02 7.5
0.2 0.7±0.02 7.5
40

0
0 1000 2000 3000 4000
Cycles

Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
Available Terminations Catalogue No. incinerate or expose
TLI-1530A/Z2/T Tags* 13 3 11532 02 contents to water.
TLI-1530A/Z2/TP Polarized tags* 13 3 11537 02
PDC19Eng

Do not charge above 4.1 V.


* with PTC SRP 200 Please refer to TLI-guidelines.

Any values given here are for informational purposes only. They also depend on actual 49 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
›› RECHARGEABLE

TLI-1550A ›› Up to 5000 cycles


›› Extremely low self discharge rate
›› Charging possible at extreme temperatures

Performance Data Discharge Curve at 25 °C


(Typical values for batteries stored at +25 °C for one year)
4.0 1: 5.0 A
System Lithium Intercalated Compounds 2: 2.5 A
3: 1.0 A
Nominal voltage 4V 3.5 4: 0.1 A
Max. capacity 330 mAh

Voltage / V
Max. continuous discharge current 2 A 1
3.0 2
Pulse current capability 5A
3
Discharge end voltage 2.5 V 4
2.5
Max. charge voltage 4.1 V
Max. charge current 100 mA 20 mA
2.0
Temperature range –20 °C ... +50 °C – 40 °C ... +85 °C
Cell impedance @ 1 kHz, RT max. 100 mΩ 0 60 120 180 240 300 360
Nominal energy 1.32 Wh Capacity / mAh
Weight 20 g
For more information please refer to page 46. Discharge Curve at 2 A
1: –40 °C
4.0 2: –30 °C
TLI-1550A/Z2 TLI-1550A/Z2/T 3: –20 °C
4: –10 °C
3.5 7 5: 0 °C
Ø 15.5-1 6 6: +25 °C
Voltage / V

5
Ø 15.5-1 4 7: +80 °C
3.0 3
2

+
+
2.5 1

7±1 2.0
7±1
0.13 3.17 0 60 120 180 240 300 360
52+2

0.13 3.17 Capacity / mAh


52+2

TLI-1550A/Z2/TP
Cycling Performance
400
350
±0.5±0.5
±0.5±0.5

300
4.04.0
3.73.7

Capacity / mAh

250
200
Ø 14.5+0.2 0.2 0.7±0.02 7.5
Ø 14.5+0.2 0.2 0.7±0.02 7.5 150
100
50
0
0 1000 2000 3000 4000
Cycles

Warning:
Fire, explosion,
and severe burn hazards.
Do not disassemble, heat
above 100 °C, short circuit,
Available Terminations Catalogue No. incinerate or expose
TLI-1550A/Z2/T Tags* 13 3 11552 02 contents to water.
TLI-1550A/Z2/TP Polarized tags* 13 3 11557 02
PDC19Eng

Do not charge above 4.1 V.


* with PTC SRP 200 Please refer to TLI-guidelines.

Any values given here are for informational purposes only. They also depend on actual 50 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Safety &
Transport Regulations
Standards Protection against charging B. A blocking diode or the Type IR max Protection against forced
General safety recommenda- Whenever lithium batter- equivalent to prevent discharge
tions for lithium batteries ies are not the single power any reverse (charging) SL-350 15 mA Forced discharge of a cell can
have been published in the source in a circuit the follow- current and a resistor to SL-360 50 mA occur when it is connected in
standards UL 1642 and IEC ing measures are recom- limit current in case of a SL-361 20 mA series with other cells. A by-
60086-4. mended by the Underwriters diode failure. The resistor SL-550 15 mA pass diode should be provided
Laboratories: should be sized to limit SL-560 50 mA in parallel with each cell in a
UL-recognition the reverse (charging) SL-561 15 mA series connection. The effect
Tadiran Lithium Batteries are The battery should not be con- current to the maximums SL-750 15 mA of a by-pass diode is that cur-
recognized by UL under file nected in series with an elec- IR max shown in table 1. SL-760 50 mA rent passes through the diode
MH 12827, please refer to trical power source that would SL-761 20 mA if a cell has been discharged,
UL ONLINE CERTIFICATIONS increase the forward current In addition to this UL require- SL-850 15 mA preventing forced discharge.
SL-860 50 mA
DIRECTORY for further infor- through the battery. ment, which gives the safety
SL-861 20 mA
mation. The following text or limits, Tadiran Batteries rec- REACH and RoHS
SL-886 25 mA
a modified version thereof The circuit shall include one of ommend to limit the reverse All Tadiran cell are compliant
SL-889 20 mA
appears on each battery: the following: (charging) current to values SL-2770 15 mA with REACH regulation and
below 10 µA. This will ensure SL-2780 50 mA RoHS directive.
WARNING: A. Two suitable diodes in that service life is not affected. SL-2790 100 mA
Fire, explosion, and severe series with the battery to SL-2870 15 mA
burn hazard. Do not recharge, prevent any reverse (charg- SL-2880 50 mA
disassemble, heat above ing) current. The second TLM-1520HPM 25 mA
100 °C, incinerate, or expose diode provides protection TLM-1530HPM 50 mA
contents to water. if the other one fails; or TLM-1550HPM 100 mA
Table 1: Maximum reverse current

Classification of lithium System Size Type Exempted1) Lithium UN Test UN Number


batteries, lithium hybrid content [g] passed
batteries (PulsesPlus) and or nominal
lithium ion batteries energy [Wh]
Lithium metal batteries and Lithium BEL SL-840 Yes 0.13 g Yes 3090/91
lithium hybrid batteries are Thionyl 1 ⁄10
C TLH-2450 TL-2450 Yes 0.18 g Yes 3090/91
dangerous goods, UN No. Chloride 1 ⁄10
3090. Lithium ion batteries (LTC) D SL-889 Yes 0.3 g Yes 3090/91
1 ⁄6
are dangerous goods, UN No. D SL-886 Yes2) 0.5 g Yes 3090/91
3480. Table 2 indicates which 1 ⁄2
AA SL-350 SL-550 SL-750 SL-850 Yes2) 0.35 g Yes 3090/91
Tadiran lithium cells are 2 ⁄3
AA SL-361 SL-561 SL-761 SL-861 Yes2) 0.5 g Yes 3090/91
exempted from the dangerous
AA SL-360 SL-560 SL-760 SL-860 Yes2) 0.65 g Yes 3090/91
goods regulations and which
C SL-2770 SL-2870 No 2.5 g Yes 3090/91
are not.
In air transport, exemptions D SL-2780 SL2880 No 5g Yes 3090/91
are limited. DD SL-2790 No 10 g Yes 3090/91
1 ⁄2
Hybrid Layer AAA HLC-1020 Yes 0.07 Wh Yes 3090/913)
For more information on Capacitors 1 ⁄2
AA HLC-1520 Yes 0.22 Wh Yes 3090/913)
classification and transport (HLC) 2 ⁄3
AA HLC-1530 Yes 0.4 Wh Yes 3090/913)
regulations, please refer to
Tadiran’s technical notice: AA HLC-1550 Yes 0.86 Wh Yes 3090/913)
1 ⁄2
tadiranbatteries.de/regulations. TLM batteries AA TLM-1520HPM Yes 0.04 g Yes 3090/91
2 ⁄3
AA TLM-1530HPM Yes 0.1 g Yes 3090/91
UN tests AA TLM-1550HPM Yes 0.4 g Yes 3090/91
Table 2 also shows the sta- TLI batteries 1 ⁄2
AAA TLI-1020A Yes 0.09 Wh Yes 3480/81
tus of UN-tests for Tadiran 1 ⁄2
AA TLI-1520A Yes 0.3 Wh Yes 3480/81
Lithium Batteries accord- 2 ⁄3
AA TLI-1530A Yes 0.5 Wh Yes 3480/81
ing to the UN Handbook of
Tests and Criteria, part III, AA TLI-1550A Yes 1.32 Wh Yes 3480/81
Table 2: Classification of Tadiran Lithium Batteries 1) if conditions mentioned in Tadiran’s technical notice are fulfilled
sub-section 38.3. Regard-
2) see also IATA DGR under UN 3090 / PI 968 / Table 968-II
ing Tadiran Lithium Batteries
3) within a PulsesPlus combination
not listed in table 2, you
may find a confirmation at
tadiranbatteries.de/reports.
PDC19Eng

Any values given here are for informational purposes only. They also depend on actual 51 Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN
conditions of use and are not warranties of future performance. Subject to change. GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de
Tadiran Lithium Batteries – Applications
Utility Metering Tracking
Automatic meter reading (AMR) Animals
Electricity, gas, water, Corrosion
heat, calorimeters Data loggers
Heat cost allocators Electronic toll collection
Prepayment meters On-board units
Communication modules Personal
Smart electricity meters Pipelines
High end consumer with a GSM module
Railways
Diving computers
Trucks, containers, trailers
Military Set top boxes
Emergency Power Sports electronics
supply for UAVs Alarm and security systems
Fuzes Smoke detectors
Gas masks Wireless alarm systems
Guidance systems PIR detectors
Night vision goggles Cash transport and
Targeting devices asset protection systems
Ejection seats Offender monitoring systems

Airbags
Automatic collision
devices
Beacons Belt tensioners
Buoys Brake controllers
Life jacket lights Communication modules
Oil drilling / MWD Digital tachographs
Seismic sensors Doors / latches
Underwater Engine controllers
positioning systems In-car computers
Off-shore Stolen vehicle
recovery systems
Telematics / eCall
Defibrillators
Tyre pressure
Dispensers monitoring systems
Implantable devices Automotive
Infusion pumps Process automation
Surgical instruments Wireless sensor networks
Medical Electronic scales Controllers
Cash machines Fault detectors
Gambling machines
Point of sale terminals Industrial PCs
Taximeters
Telephone Process logic control
Vending machines exchange boards
Instrumentation Office automation Industrial automation

Lithium Thionyl Chloride (LTC) Batteries


Your Distributor PulsesPlus  TM Batteries
Tadiran Lithium Metal Oxide (TLM) Batteries
Tadiran Lithium Ion (TLI) Batteries
PDC19Eng

Tadiran Batteries GmbH • Industriestr. 22 • 63654 BÜDINGEN


GERMANY • Tel.: +49 (0)6042 954-0 • www.tadiranbatteries.de

S-ar putea să vă placă și